Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS-r Date: 3 j'j %3 Fee Due: j. ,Z)Receipt# q I a 1,5 Permit # l3 O 3 -d 0,a Planning & Development Services Building & Code Regulations Division C'91V/V" 2300 Virginia Ave. Fort Pierce, FL 34982 (772)462-1553 county SPECIALTY PERMIT APPLICATION ❑ Electrical ❑ Plumbing El i" 7AC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding Seepage 2 for instructions and additional paperwork required for specialtypermits 1. Location/Site Address / I__ Ca-5 e (� I ' r0d 1'/-e- rcc- 3L19q-F 2. Parcel ID Number: r 141 Li -7 O /- o 1 9 a- 0 o v- 9' Office Use Section Township Range Map Page Zoning Land Use Initials Only �+ 3q 40 � L') /T /�4 S R/ —S.— T- SE P—e 5. -90 A , 8 IC.w , 2. 4. Owners Information5. Contractors Information Name: A o+2�, 1A o2,QS Toy--, FL Reg/Cert #: Address: �k L"+k.P CA • County Cert#: n l0-1 City: -7�764 � I-ext-e- State: FL. Business Name: C �l� \Y�2CuQe ct Zip: jL %Ll Phone: Phone: 111 �klo$-IIoCYP Fax: 6. Value of Construction: $ WQZ2S OWNERS AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws replating construction and ning. PRINT OWNER OR CONTRACTOR NAME SI(NATURE OF OWNER OR CON RACTOR STATE OF FLORIDA, COUNTY OF St- _ Ta-ici P ACKNOWLEDGED BEFORE ME THIS 1 dth DAY OF Marc , 201 3 BY S�lpl T O�g01tB191111 � ��, �.�NE E. CqB i `/ � WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED •m•ammrmm• •� o AS IDENTIFICATION. - * ; s co ��JJ Aime Cabral m mom #bb 9481 a1) SI ATURF,0F NO TYPE OR PRINT NAME OF NOTARY j9�°°' ��aontledfiiN ems.' ��� Ob/!ti N�s� pQe COMMISSION NUMBER NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 Revised 04/26/2010 3/14/13 i Mary ionise Nordstrom (LFEST) Record: 1 of 1 Property Identification Site Address: 11 Castle Ct See/Town/Range: 14 :34S :40E Map ID: 14/14S Zoning: RS-4 Ownership and Mailing Owner. Address: Sales Information Date Price 5/9/2003 100 5/1/1977 56000 Property Appraiser - SLLucie County, FL PROPERTY RECORD CARD <<Prev Next» Spec_Assmnt 'faxes ParcelID: 1414-701-0192-000-8 Account #: 7598 Use Type: SF Res City/Cnty: St Lucie County Legal Description Exemptions Permits Home Print CIEcoG Mary Louise Nordstrom (LFEST) Mary Louise QUEENS COVE -UNIT 1- BLK 19 LOT K(OR 267-2676: 1712-2551) Nordstrom (TR) 11 Castle Ct Fort Pierce FL 34949-8305 Assessment 2012 Total Land and Building Code Deed Book/Page 2012 Final: 216600 Land Value: 144600 Acres: 0.25 01 WD 1712 / 2551 Assessed: 174326 Building Value: 72000 00 CV 0267 / 2676 Ag.Credit: 0 Finished Area: 1394 SgFt Exempt: 50500 Taxable: 123826 T axes: 2699.44 4 f84� BUILDING INFORMATION � s � •o ► I L ' `�r�l Exterior Features View: - RoofCover:. CS - Cone Shingle RooiStmct: HP - Hip ExtType: HC+ - HC+ YearBlt: 1976 Frame: - Grade: C+ - C+ EfIYrBlt: 1977 PrimeWall: BS - CB Stucco StoryHght: 0010 - 1 Story No.Units: 1 SecWall: Interior Features BedRooms: 3 Electric: NIX - MAXIMUM PrmIntWall: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHt/Fl: STD 1/213ath: 0 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet a/aA/C: 100 °/aHeated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type WS Qty. Units Qual. Cond. YrBlt. No. Use Type Type Measure Depth DOK2 — WOOD DOCK Y 1 78 AV AV 1977 1 0100-SF Res 240 -Front Ft 50 100.09 2 0100-SF Res 205 -Front Ft 60.05 100.09 SDSF — SITE DEV S-F Y 1 1 AV AV 2001 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. wmw.paslc.org/paslc/prc.asp?prclid=141470101920008 1/1 This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. Certificate of Product Ratings AHRI Certified Reference Number: 3412355 Date: 3/14/2013 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 14AJM30 FILE COPY Indoor Unit Model Number: RHLL-HM3617+RCSL-H*3617 Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM 14AJM SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (13tuh): 29200 SEER Rating (Cooling): 16.00 * Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except forthe user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information forthe model cited on this certificate ran be verified atwww.ahridirectory.org, Air -Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on A. which the certificate was issued, which is listed above, and the Certificate No., which is listed below. .; `' and Refrigeration Institute ©2012 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130077575306060638 Project 14.',u�:`nmary Entire House FI L E FL Email: 2shawnrussell@bellsouth.net For. Mary Louise Nordstrom, Advantage Air Conditioning 11 Castle Ct, Fort Pierce, FL 34949 Notes: Email: 2shawnrussell@bellsouth.net Design Information i Job: 2685 Date: March 14, 2013 'Sy: Debbie Russell Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative f�umidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 21259 Btuh Ducts 3666 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 24925 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heading Cooling Area (ft2) 1344 1344 Volume (ft3) 12096 12096 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 91 46 Heating Equipment Summary Make Trade Model AHRI ref no. n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 0 Btuh 24925 Btuh 23 OF 973 cfm 0.039 cfm/Btuh 0 in H2O Structure 16960 Btuh Ducts 7318 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 23064 Btuh Latent Cooling Equipment Load Sizing Structure 1937 Btuh Ducts 1530 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 3467 Btuh Equipment total load 26532 Btuh Req. total capacity at 0.70 SHR 2.7 ton Cooling Equipment Summary Make Rheem Trade RHEEM 14AJM SERIES Cond 14AJM30 Coil RHLL-HM3617++RCSL-H`3617 AHRI ref no.3412355 Efficiency 13.0 EER, 16 SEER Sensible cooling 20440 Btuh Latent cooling 8760 Btuh Total cooling 29200 Btuh Actual air flow 973 cfm Air flow factor 0.040 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.88 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wri htsoft' 201s-Mar-1414:14:18 �+� g RightSuite® Universal 2012 12.0.04 RSU09070 Page 1 /IS..Vr� C:%Usem%Shawn RusslhDowmentsXALL wRIGHTSOFTINFOWORDSTROM rup Cale = MJ8 Front Door races: i Volumetric Concrete Dispenser Mix Design Mrksheet OWNER Mobil Crete Technologies Unit Serial # 1 YOUR MIX DESIGN (This sheet must be filled out for each mix design) MIX DESIGN .3000 PSIum Pp Mix (max 8 characters) Materials of one cubic yard: Date ` ' .1 H4/2­0!3 Cement 530.- - LBS. 100% i Cemerit Discharge Speed 95 Counts per,Bag of Cement (In.Percent) Cement 5.6 BAGS 1.37 Cubie,Yard Discharge Time (Minute) Aggregate Pounds of Aggregate Name # Desired Aggregate Name Aggregate (enter 1, 2, 3, or 4) 1 Screening Sand Aggregate I,' 1 Screening Sand 1500 2 Pea rock 3/8" Aggregate 2 2 Pea rock 3/8" i 1.539 3 Rock #67 4 0 Color OUNCES Fiber Chopper Pounds per Yard Low, Mid, or -High Sys Dilution Oz/bag Admix # 1 Admix #2 1 1 Admix # 3. 'I I. ' (Mid Range available on 130, 150, & 200 Series units only) 1. Determine the count per cubic yard. 5.6 bags/cubic yard x 95 counts per bag = 538 count per cubic yard. 2. AGGREGATE 1: Divide the lbs. of fine aggregate per,cubic yard by the count per cubic yard. 1500 lbs. fine aggregate divided by 538 counts per cu. yd.= 2.79 lbs. per count. GATE SETTING (from graph) 6A 3. AGGREGATE 2- Divide the lbs; of coarse aggregate per cubic yard by the count per cubicyard., 1539 lbs. coarse aggregate divided by 538 counts per cu. yd.= 2.86 lbs. per count. GATE SETTING (from graph) 5.8 Description 3000 PSI Pump Mix Total 538 Counts / Cubic Yard Cement 0.99 lbs.! Count Dial Aggregate 1 2.79 lbs./ Count Setting Oz/Min Aggregate 2 2.86 IbsJ Count Admix # 1 ERROR 0.0 *Water 0.00 lbs./ Count Admix,# 2 ERROR 0.0 Aggregate 1 Gate 6.1 Admix # 3 ERROR 0.0 Aggregate 2 Gate 5.8 Color #DIV/0! 0.0 Water Meter; Fiber Chopper #DIVlO! 0 At this point we recommend that you run a 114 yard yield test. You must have a box that is 1/4 cubic yard: You can build one with internal dimensions of 36" -x 36" x 9".'You start the unit producing concrete. Stop both the conveyor and mixer at the same instant. Set the 1/4 cubic yard yield box under the discharge. Start the mixer and conveyor at the same time. Run the unit to the amount indicated for 114 cubic yard (1 /4th of the meter count per cubic yard, from step 1). Shut off the mixer and conveyor at the same instant. The box should be full. It may be necessar-y to adjust the aggregate gates slightly to adjust the vield. 1/4 Yard Count 134 RECEIVED AUG 212013 If you have a water recording meter your lbs./Count will be approximately 1.0425. SRM 08-10