Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE ONLY: Date: Fee Due: Receipt# Permit # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 Virginia Avenue SCANNED o . . . . . . Ft. Pierce, FL 34982-5652 BY 772-462-1553 St. Lucie County APPLICATION FOR ALUMINUM STRUCTURES PERMIT ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: ZAy� �, 1021 Va'-1 2. PROJECT NAME: SITE PLAN NAME: 3. PROPERTY TAX ID ':2 4-n -,?A j :2,9 0 5-0 4. LEGAL DESCRIPTION (attach extra sheets if'necessary): wsg—(geg�'@- 5. PLAT BK PAGE BLOCK LOT 6. PARCEL SIZE: ACRES/SQ FT. LOT DIMENSIONS 7. SETBACKS (ACTUAL) FRONT: BACK: Alft RIGHT SIDE: k LEFT SIDE: 8. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A = Addition SG = Slab on Grade SR = Raised Slab DIMENSIONS SQUARE FEET OF R = Rebuild WD = Wood Deck CONSTRUCTION El SCREEN ROOM 1-1 NEW El EXISTING X El CARPORT/PATIO ROOF 1:1 NEW E EXISTING X 1:1 HABITABLE GLASS ROOM El NEW El EXISTING X El CAT 1, 2 OR 3 SUNROOM ❑ NEW 0 EXISTING X 1:1 ALUMINUM COMP. SHED ❑ NEW [?—EXISTING X 9-'POOL ENCLOSURE ❑ NEW EXISTING 2- X 72- ❑ M H ROOF OVER El NEW ❑ EXISTING X ❑ ROOF SYSTEM OVER ❑ NEW ❑ EXISTING X EXISTING ACCESSORY STRUCTURE 1:1 OTHER: El NEW El EXISTING X El ALUM POOL FENCE Linear feet TOTAL SQUARE FOOTAGE OF CONSTRUCTION 9. VALUE OF CONSTRUCTION: $ The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev.0412612010 OWNER INFORMATION �` NAME: V 4C ,e J J e --74A, 9 ADDRESS: S / / .f "*0 CITY: & /21 G/ STATE: ZIP PHONE (DAYTIME): 9d1 / 6 S Z. EMAIL: q -r J U'v a. Can 3 S`" �d' FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): �) CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: ST. LUCIE COUNTY CERT #: BUSINESS NAME:gJ`� QUALIFIER'S NAME: U ADDRESS: CITY: / STATE: ZIP PHONE (DAYTIME): () FAX NO. email: ARCHITECT/ENGINEER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): �) NOTE: I F APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) OFFICE USE ONLY, SECTION TOWNSHIP RANGE MAP NO. ZONING LAND USE C LOT CVG % Additional Permits -. V Required REPORT BIMS FEE $ MISC FEES $ TOTAL FEES $ CODE BUILDING & ZONING REVIEW FRONT PLANS VALUE OF CONSTRUCTION REVIEW COUNTER ZONING SUPERVISOR EXAMINER VEGETATION USING ICC TABLE DATE 320113 �' r COMPLETE INITIALS 1 CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not exceed t footprfift of thQ,structure tl3at was in existence prior to removal by t e storms. ATURE STATE OF FLMIDA COUNTY OF 15)r . L V c The foregoing instrument was acknowledged before me me this 4 hday of -MOg f - , 2013 , by GT. ^a`3 Samka V i who is personally known to me, or who has produced TVD L C-2%W —9kA8 as identification. DEANPIA GIVENS' Notary Public - State 01 Florida • .: My comm`. ExPU EE 8587611 Signature of Notary :,�Jy�f oQo� Comm) ��i�„OF FN� Bonded Through National Ugly �s IMPORTANT NOTICES: CONTRACTOR SIGNATURE STATE OF FLORIDA COUNTY OF The foregoing instrument was acknowledged before me me this day of , 20 , by who is personally known to me, or who has produced as identification. of Notary (Seal) • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNERBUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/BLDR AFFIDAVIT. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. Planning & Development Services Department Building & Code Regulations 2300 Virginia Avenue Fort Pierce, Florida 34982 (772)462-1553 OWNER/BUILDER AFFIDAVIT DISCLOSURE STATEMENT F.S. 489.103 (7) EXEMPTIONS State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You may build or improve farm outbuildings, a one -family or two-family residence or a commercial building at a cost of under $75,000.00. The building or residence must be for your own occupancy. It may not be built or substantially improved for sale or lease. If you sell or lease a building you have built or substantially improved your self within one year after the construction is complete, the law will presume that you built or substantially improved it for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building; it is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who is not licensed must work under your direct supervision and must be employed by you, which means that you must deduct F.I.C.A. and withholding tax and provide 7rkKs' compensation for that employee, all as prescribed by law. Your construction must comply with all applica s ordinances, building codes, and zoning regulations. Initial I understand that the building official and inspectors are not there to design or give advice on the minimum code. Initial I understand that as an owner -builder that any contract disputes with sub -contractors and ymu in a civil court with the advice of an attorney. This department will not mitigate any contract disputes. Initial I understand that if I compensate any person or company for work performed they acre licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and cost of the license. Initial I understand that if any person that is unlicensed and uninsured gets injured on my con: they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer ant cost, which could include loss of wages during recovery from their injury. Ini To qualify for this exemption under this subsection, an owner must personally appear andG permit application and initial the above. I hereby acknowledge that I have read and understand the above disclosure statement and that I further understand that any violation of the terms of the owner/builder ex Zoning Department to the Florida State Department of Professional day of of 20 — STATE OF FLORIDA COUNTY OF The foregoing instrument was acknowledged before me thisAst_60 day of Yq , 20 3 , by &i-V. A vJ % who is personally known to me, or who has produced Dt -00 -� -l-R-a as identification. �n G v 4 V S DEANNA GIVENS �� Y P h Signature of Notary Type or Print Name of NotaV `rMr." � jM)public - State of Florida Title: Notary Public Commission Number � sd��.= My Comm. Expires Dec W'1016 °�- 858761 • -a1 Commission W Cr SLCPDSD Revised 07/22/2010 Bonded Through National Notary Assn. Property Appraiser - St.Lucie County, FL Page 1 of 1 PROPERTY RECORD CARD Gregory J Sawka Record: 1 of 2 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification ��t1CIE CO Site Address: 4511 S INDIAN RIVER DR ParcellD: 2436-321-0005-000-6G� y Sec/Town/Range: 36 :35S :40E Account #: 33851 € Map ID: 24/36S Use Type: SF Res Zoning: RE-2 City/Cnty: St Lucie County Ownership and Mailing Legal Description Owner: Gregory J Sawka Donna M Smith 36 35 40 BEG AT PT ON E R/W LI FEC RR 227.65 FT NWLY OF S LI Address: 4511 S Indian River Dr OFN 11.36 CHS OF GOV LOT 2, TH CONTALG Fort Pierce FL 34982-7732 More... Sales Information Assessment 2012 Total Land and Building Date Price Code Deed Book/Page 2012 Final: 201900 Land Value: 130000 Acres: 0.57 12/14/1989 103000 00 WD 0668 / 2578 Assessed: 145799 Building Value: 71900 3/1/1988 84200 00 CV 0580 / 0514 Ag.Credit: 0 Finished Area: 2946 SgFt 10/1/1985 89500 00 CV 0481 /0870 Exempt: 50000 1/1/1981 72800 00 CV 0346 / 2272 Taxable: 95799 12/1/1979 65000 00 CV 0322 / 1026 Taxes: 2132.41 BUILDING INFORMATION Exterior Features View: RoofCover: SD - Dim Shingle RoofStruct: GA - Gable ExtType: HC+- HC+ YearBlt: 1909 Frame: Grade: C+ - C+ EffYrBlt: 1955 PrimeWall: WS - Wood/Sheath StoryHght: 0020 - 2 Story No.Units: 1 SecWall: Interior Features BedRooms: 4 Electric: MX - MAXIMUM PrmintWall: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHt/FI: 1/2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: HW - Hardwood %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Use Type Type Measure Depth PA01 - POOL DK-AVG Y 1 438 AV AV 2004 1 0100-SF Res 225 -Front Ft 101.2 247.5 SPA - SPA -HOT TUB Y 1 36 AV AV 2004 SWAY - RES POOL AVG Y 1 450 AV AV 2004 ENC2 - POOL ENC-AVG Y 1 924 AV AV 2004 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.pasle.org/paslc/prc.asp?prclid=243632100050006 3/15/2013 FROM:SOUTH COAST 7723446042 P.1/1 1-JUL-2012 05:1- 1 12.40 PERMIT # i A;,L r Q O3- BUILDER/CONTRACTOR: PEST CONTROL CONTRA PEST CONTROL LICENSE We, the undersigned, hereby subterranean tttrmft$ 1nam Square tfeet if arm treated: Perce tage of solution: Vwx of T?o�Mert!~ - —foo rig - V0 Trutt ae-,1et ---1, Treatment � e-Treatr R&Treat There mint be a mo ptitled A a& 0 be ~ upby Me AVe cmr A* d reel .46 cvma&p arm stha�llx►prravbiedGp n�l{�t dtr Pmwft a aqwfhrbbeprr" d*P DMtal*W &88ft] 7t. ffb*o--W ld)W, be au> dp *r4p AWbu&ft aW SLC AMe cart Pie m FL 34982 462-2173 !ON 772462-�.H ti TE OF TERMITE WC SOIL TR ADDRESS: T0:4626443 TMENT PACE 01/01 19f r,4ci1:-/v UR: y tW we hm pretreakd flte Am des;MW won for e wfth the standards of the National Past Control Assodadom a,wWaft used:. Total galore used: -Z --" Time of ,stab .Pertmetier for . rtal ktspectfon �, _ e 5lgrt wm of [6ctermrmebtir Ar Awd mqu kw &w&naw ar dv of earn kaWacUm ord`tes I w;t hrp+ ri offt7nAm A gone* Q mgwr ae awh lequierl, !dart w7d wfi9w►d'#a&W rnxd, 0 h rA!rmeefred1br>b m#fprelvle* �t sir thb �brm mw6ttbrr cn b'x job esther�b�►XjraGtsAep biarrd 680mirtr ft"W ^YW fibm >he rnbnnt +dr cf d*bwbner jo bavn am popw i "mom Ierard of St Lucia Coualy r+equkes fbr th4 floal inspecdon for CD, a Perrnn�*" SUcketr W be platted on St. Lucie Coulnty Building & Zo>Ining DepalrUlueint 2300 Virginia Avenue Fort Pierce, Fr, 34982 772-462-2105 Fax 772-462-6443 Request for 30-Day Temporary Power Re.ea ie s Date: Permit Nuxber.:_0 �. �.�..- Property Address,--�.-1- THE UNDERSIGNED .HEREBY REQUEST RELEASE OF ELECTRTCAI POWER TO THE ABON7E DESCRIBED PROPERTY, FOR A PERIOD NOT TO EXCEED I HIRTY (30) DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PRE PAI;ATTON FOR FINAL INSPECTION. IN CONSIDERATION OF .APPROVAL OF THE REQUE�,T WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS: 1. This temporary power release is requested for the above stated purpose only, during this time period. 2. As witness by our signatures, we hereby agree to abide by ali terms and conditOns of this agreement, including Building Division Policy, which is incorporated lie- ein by reference_ 3. All conditions and requirements listed in the attached document entitled "Requirement's for 30 Day Power for Testing" have been fulfilled and the prep; ise is ready for compliance inspection. 4. All requests for an extension beyond 30 dayq must be made in writing to the Building Official stating the reason for the request. knower may be removed from the site and/or a Stop Work Orc er issued if the Final Inspection has not been approved within 30 days. A, fee of $100.00 will be required to lifl the Stop Work Order_ WE IT:I REBY RELEASE .AND AGREE TO HOLD HARMLESS, ST. LUC(E COUNTY, AND THEIR EMPLOYEES FROM. ALL LIABILITIES ,AND CLAIMS OF ANY TYPE OF NATURE WHICH MAY ARISE NOW OR IN THE .FUTURE OUT OF THIS TRANS 4CTION, INCLUDING ANY DAMAGE WHICH MAY BE INCURRED DUE TO THE DISCONNI MON OF ELECTRICAL POWER .T.N ' , EVENT OF VIOLATION OF THIS AG)R EFMFNT. RICAL CONTRACTOR SIGNATURE n\\" %l W- �Ax. DATE RECEIVED JUL 13 2012 CONTRACTOR: VH Exteriors'_ 1c. DESIGN CRITERIA: Applicable Codes, Regulations, and Standards 1. The 2010 Florida Building Code specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2005 Edition 3. ASCE 7-10. Wind Loads 1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category 1. 2. Basic Wind Speed, Table 1609C State of Florida Debris Region & Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: 150 MPH. 3. Exposure Category, Paragraph 1609.4.3: C 4. Screen roof enclosure, Table 2002.4. Foundation Design Footing Size: Existing concrete. No additional concrete footing or slab is required to resist the loads imposed by the proposed construction if the existing slab is a minimum 4" thick with an 8" x 8" thickened slab edge and in sound condition, free from structural cracking, spalling, or other deterioration. Specifications The following specifications are applicable to this project: 1. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulaiory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the. following i. Portland Cement Type 1,- ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/- 1 % - ASTM C 260 iv. Water reducing agent - ASTM C 494 _ v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM Al85 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after batching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. -Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 2. Aluminum extrusions shall be 6005 T5 Alloy 3. Fasteners are required to be SAE Grade 2 or better zinc plated. 4. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or #12 screws 6" from ends and 12" center to center. 5. The minimum nominal thickness of protector panels (kickplates) shall be an industry standard of 0.024 inches. 6. Screened enclosures containing swimming pools shall comply with the applicable requirements of FBC R4101.17 Residential Swimming Barrier requirements. 7. Screen material shall be 18/14 screen unless approved by Suncoast Architecture & Engineering, LLC. 8. Door location shall be determined by contractor in the field. 9. When installing pavers over concrete slab or footing which are supporting aluminum members, such as continuous screen tracks or upright, the pavers must be bonded to the concrete with an epoxy, thinset, or 3,000 PSI grout to ensure full positive contact with concrete. 10. Design shall be based upon "pinned" upright analysis unless approved by Suncoast Architecture & Engineering. Roof Type Roof Type: Mansard 8'-1" 6'-6" 7'-1" c-1 1X2(TYP) 1X2 1X2\,7+-+ r 0- I I m �N X X� XN N N N X N i i — — — — — — — — — — — — — - x A-3 1X2 2X4P.B. FLAT (TYP) FLAT \2X2 AREA 2X. N X in 0 N N N N (0 X N 0+2 NI(n C+/ XI(n t\ 00 T ESE PLANS AND ALL PROPOSED WORK, ,.ARE SUBJECT TO AWF CORRECTIONS REQUIRED E r ELD INSPECTORS TKAT PRE NECESSA.RY.d19 ORD TO �9�0:MAY 0iPLT . _ - ALLPL9�A®CE CODES, 2X4 M y� a- V } X N L,&-'+r ti. I- LA I (TYP) W 36'-6" - - - - - - - - - - - - - - - - - - - - - -- S m A-3 X X:5 XX:2 X:2 �-X N (n N (n N (n N (n 42„ I \- 4„ L 3,-O„ 2X2 I 2X2 I 2X2 I 2X2 1X2 I 1X2 A 1X2 -1 1X2 1.X2(TYP) EA- -iC H- 4 A-2 A-2 A- 7'-6" 7'-4' 8'-1" 6'-6„ 7'-1" II M 9®0®g50�aB8Bpg0. C1 mm 9 p P Z e Lu (0 -PIC LLJIT cr) a X/ ° r� o PROFESS T1At SEALO N ��- X N X N 2X5 SMB N N N X 2X5 Z N X S. LUC E COUN i Y ALTI.LDING DrMION, REVIEWED -FOR OMP REVIEWED B � DATE ]PLANS AND PLIOUT 1viUST BE KEPT ON JOB UZNO INSPECTION WILL BE MADE. w LU Z L! 3 a LU o a a� Z 0 o 2z Ui W N Z J LLU W Q 0 0 LLJ Cr (Z M w %-fLU U � J ~ W U Q Z_ OLU ' Q Z WLLmm O F 'inn Z Z W/� ;A N (Z W J , L) W tii to LL! co 00 co Q Q LL b Z U I �viw tZ co -tLL EL DATE DRAWN 02/12/13 REVISION SHEET NO: A-1 ALUMINUM MEMBERS DIMENSIONS o9o�a a : a a ;'i BB Joe HOLLOW SECTIONS 2x2: 2"x2"x0.044" 2x3: 2"x3"x0.050" 2 x 4: 2" x 4" x 0.050" NEW CONT. 2" X 0.046" "H" ,• " s `1' •- • O t !Y �9 2 x 5: 2" x 5" x 0.050" SECTION BETWEEN THE NEW 2" X 2" X 0.046" SECTION c e (o CD CO LL• o AND EXISTING 2 X 5 SMB WITH #10 AT 12" O.C. z c Lu co W OPEN BACK SECTIONS (2) 1x2: 1"x2"x0.040" 1x3: 1"x2"x0.045" I "I I 0 1�- i, Z 1 I 17-, iQ- • (� e b 'I' p °' ' ✓ SNAP SECTIONS 2 x 2 Snap: 2" x 2" x 0.045" 1/8" X 2" X 2" X 2" WIDE EXTRUDED ANGLE EACH I UPRIGHT 11/8"X2118"X11/8"X2" LONG X 0.040" RECEIVING CHANNEL (2) #12 X 3/4" SMS I I 'e --?°r S • • (1 , 6 • • s�Q ,ram 2 x 3 Snap: 2" x 3" x 0.050" SIDE #14 X 3/4" SMS INTO INTO EACH FLANGE/WEB dp�,# �,`i (2) i I I I qq0$`§ 2 X 4 Snap: 2" x 4" x 0,045" UPRIGHT (1) 3/8" X 2 1/4" �RoF �$jQNAO �EAL SELF MATING (SMB) CONCRETE SCREW ANCHOR I I ' 1/8" X 2" X 2" X 2" WIDE 2 x 4 SMB: 2" x 4" x 0.044" x 0.100" EXTRUDED ANGLE EACH I �' 2 x 5 SMB: 2" x 5" x 0.050" x 0.100" SIDE (3) #14 X 3/4" SMS INTO W 2 x 6 SMB: 2" x 6" x 0.050" x 0.120" • UPRIGHT (1) 3/8" X 31/2" • • — — — — I LLJ Z LL! 2 X 7 SMB: 2" X 7" X 0.057" X 0.120" I • • CONCRETE SCREW ANCHOR I 2 x 8 SMB: 2" x 8" x 0.072" x 0.124" 2 x 9 SMB: 2" x 9" x 0.072" x 0.124" i.---- 1" x 2" O.B. BASE PLATE - TYP 2" x 2" OR 2" x 3" I I Z Q rn 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" 1M'Mli i CONC BAN HOR EMBEDMENT MEMBER W/1"X2"OB I I W (fj O J b A' °' a 2" STITCHED TO BACK SIDE OF CHAIR RAIL W/ #12 X 1 1/2" @ Q �' tD q' MIN a 5d MIN EDGE DISTANCE FROM s"o.c. I I Z p y 0 EXTERIOR OF COLUMN TO �� SNAP OR SELF -MATING BEAM Z • OUTSIDE EDGE OF SLAB ONLY N Z w 3/8" DIA. CONCRETE SCREW LL. > 0 ANCHORS (21/4" CONC._/ EMBED) EACH SIDE OF C W OJ UPRIGHT PURLIN OR GIRT TO BEAM OR POST DETAIL a N LL A-2 SCALE: NTS W RETROFIT UPRIGHT TO CONCRETE DETAIL A_2 SCALE: NTS N LLI S _jrlLr. �;UFY o Lu G� Wtmog ci Q Z waj cp N 3116" 5052-H32 GUSSET #14 SMS @ 1 1/4" O.C. Cf7 G'I u ;4 z `-- m Q LL, 0 1/8'X2"X2"X2"WIDE EXTRUDED ALUMINUM 2°x2"PURLINSATTACHEDTO 1/8'X2"X2°X2"WIDE In co d r " ANGLE EACH SIDE (3) #12 X i BEAM w/MIN (4) #10 x 1 1/2" SMS PLACE WASHER UNDER SCREW EXTRUDED ALUMINUM ANGLE EACH SIDE (3) #12 X 3/4" SMS EACH FLANGE 6 IN GUSSET CORNER 3/4" SMS EACH FLANGE i F i 2X4 P.B. FLAT i • • • \ T 2X4 P.B. FLAT / • • ILIA • • �� N • • W cl) 00 • • • i� 11/4"TYP • • • • M Q Z LL 1/8'X2"X2"X2"WIDE i • • 5/8" TYP \ 5 F5 LLI EXTRUDED ALUMINUM • \ / 3 —I, 1/8'X2"X2"X2"WIDE Z ANGLE EACH SIDE (3) #12 X • i i ?. -" \ 3„ S 8" EXTRUDED ALUMINUM ANGLE EACH SIDE X Q � W Y 3/4" SMS EACH FLANGE (5) #14 X 3/4" SMS EACH SIDE • _ X 8 3/4" SMS EACH FLANGE AN Q ?j r- D" 5" Q Ln F-- f2 cn . LL REINFORCE EXISTING 2X5 SMB UPRIGHT SEE S/A-3 8" - 5„ NOTES: REINFORCE EXISTING 2X5 DRAWN BY EL S 1. GUSSET DIMENSIONS ARE MINIMUM (2) SMB UPRIGHT SEE S/A-3 DATE DRAWN REQ'D - (1) EA SIDE OF BEAM - MAY BE INTERNAL OR EXTERNAL 02/12/13 2. AS BEAM SIZE CHANGES, ADD OR SUBTRACT SCREWS TO MAINTAIN 1 114" REVISION C/C SPACING. Q - 3. GUSSET LENGTHS REMAIN CONSTANT, D UPRIGHT TO BEAM CONNECTION WIDTHS CHANGE TO MATCH BEAM SIZE. C ® _ A-2 SCALE: NTS r SLOPED PURLIN CONNECTION DETAIL E TYPICAL INTERNAL OR EXTERNAL GUSSET DETAIL - RIGID MEDIUM A-2 SCALE: NTS SHEET NO: A-2 SCALE: NTS A-2 2" x 2" x 1/8" x 4" ANGLE m Q' '^ -� ��i •` L 2" x 5" STRAP W1(4) #14" x 3/4" IN EACH PROVIDE (2) #14 x 1" INTO GJ _ o LEG AND (2) #10 x 3" EACH MEMBER AS INDICATED m :5f I _ SCREWS THRU BELOW , LL} �• !tJ •�<� TOE BOTTOM OR SIDES NEW CONT. 2" x 2" x 0.046' ATTACHED TO THE BACKSIDE — — — NOTE: m •• / / Cn :� •• ' OF EXISTING 2" x 5" SMB •• •• CONNECTION DETAIL — — — `�- ��� • , ' L` • AT EAVE RAIL aq S • i. • SIMILAR j,da �\: .'+' 4:J L• • PROFS SIQNALISP.At W \ NEW CONT. ALUM 2" x 0.046" DETAIL#2 THE EXISTING NEW2CxlON 2"ANDEXISTING2" NOTE: REINFORCE BOTTOM CORNER PEN OST Z W 2" x 5" SMB x 5" SMB W/ (2) #10 x 5/8"SMS OF ROOF BRACE WITH 1" X 2" I I L AT 12" O.C. O.B. STITCHED TO BOTTOM z OF EXISTING W/#12X 1 12" AT 6" O.C. 4" x 4" x 1/8" PLATE / Lu Q 2" x 5" STRAP W/ (4) W/ #14 x 1" INTO EACH I I / J #14" x 3/4" IN EACH MEMBER AS INDICATED Q LEG AND (2) #10 x 3" / / Z O N TOESCREWSTHRU • / CC w BOTTOM OR SIDES • Jai • C N c.1 .S X2 TO EXISTING UPRIGHT DETAIL • • • • ----- — — — — — — — LuW 0 LL > O SCALE: NTS A-3 • BASE PLATE Lu a N O •:• DETAIL #1 H-1 Lu ROOF BRACING DETAIL -� SCALE: NTS 0 ' A-3 SCALE: NTS . •, �,; sv' n--'ov I— 9 u c� N W a J J ~ Uzi � z= o Q Oo So I— W Z ^ 3 2" x 2" x 1/8" ANGLE x 8" LONG En W r m o PROVIDE (5) #14 x 1" INTO EACH MEMBER AS INDICATED Q Z Q m m z 2X4 P.B. FLAT EAVE RAIL SEE D/A_2 FOR BELOW („) Z ¢ n N :3DETAIL z c • CONNECTION — — — — — — — W o CC N 03 N WOOD: • • Lill 710 x 3" WOOD SCREWS, 6" — — — — — — — ( FROM GIRT & @ 12" O.C. • • • CONC: • 1/4" x 3" TAPCONS, 6' • 2X4 P.B. 4" x 8" x 1/8" PLATE FROM GIRT & @ 24" O.C. • I I W/ #14 x 1" INTO \ EACH MEMBER AS (4) #10 x 1 12" INTO • \ I INDICATED I. SCREW BOSS00 \ \ • \ • W M I, -- 1/8" X 2" X 2" X 2"WIDE \ •\ I I W EXTRUDED ANGLE EACH • • co I I. — — SIDE OF UPRIGHT (3) #12 X 3/4"SMS INTO UPRIGHT (2) 3/8" X 6" LAG SCREW AT — — — — — — J Q Q LL 1/4" X 3" LAG SCREWS EXISTING • • • • I O W V2" RAFTERS/OVERHANG — • I — — — — — • Z 0 x 2"OR 2"X 3" HOLLOW • GIRT %� I � � (n d I SECTION GIRT • • / / - • I GIRT / � Q to F- / I G. (A 't LL 1" x 2" 4" (MIN) UPRIGHT / DRAWN BY EL DATE DRAWN 1X2 OB 1/4" LAG .. _, 02/12/13 SCREW X 2 12"AT24" , REVISION C-_ 9X2 TO HOST STRUCTURE DETAIL D.C.j//l SCALE: NTS A_3 EXISTING OVERHANG FASCIA &SUB FASCIA I..+_2Z INTERMEDIATE K-BRACE DETAIL _ Q' Q - A-3 SCALE: NTS G RISER WALL ATTACHMENT DETAIL SHEET NO: A-J SCALE: NTS A- 3___j o0e ova®effae®u8�oo .� O z : LL) LLJ o L,.� ®71>m •= J'P 'PROF. SS,(O ., o: ' a U W O W /z W J y z Q Z m W C7 e w J Q z x . COPY Q e z 0 C Z LU G w Ir V) Z � � LL > o w O LLJ F- ° a a cn LL N Q O U Z I11 N 1" x 2" O.B. FASTENED TO CORNER POST W/ #12 x 1 1/2" SMS AT 6" FROM 1/8" x 2" x 2" EXTRUDED I TOP & BOTTOM RAILS. TYPICALLY @ ANGLE 5032 H-32 ALLOY • • (4) #14 x 3/4" SMS I I I 24" O.C. • • INTO DJ I . 1/8" x 2" x 2" EXTRUDED ANGLE 5032 CORNER POST H-32 ALLOY EA CORNER W/ I I I I - SMS NTOP ST&(1)38"DIA.)#14x2" CONCRETE SCREWANCHOR INTO a [!ANCHOR 6" CONCRETE CONC(2) #10 x 1 1/2" SMSISLAB /FOOTINGBEDMENT THRU SCREW BOSSESSEE PLAN ':.y a 2114" N CONC ANCHOR EMBEDMENT • s a. . . SLAB /FOOTING SEE PLAN SIDE VIEW (1) 3/8" DIA. CONCRETE SIDE VIEW SCREW ANCHORS (2 1/4" CONC. EMBED) �2"� CORNER POST W/ 1"x2" @ (4) #14 x 3/4"SMS BACKSIDE 2" x 2" DJ INTO POST 3/8" x LENGTH AS REQUIRED FOR 2 1/4" EMBED CONCRETE SCREWANCHOR INTO CONCRETE 1" x 2" BASE PLATE ANCHORED TO CONC W/ 1/4" CONCRETE SCREW ANCHOR (MIN. 1 1/4" EMBED) 6" MAX EACH SIDE OF POST .a a . +t• `£ AND 24" O.C. MAX .6 f Q FRONT VIEW DJ-1 DOOR JAMB TO CONCRETE DETAIL A-4 SCALE: NTS 1" x 2" BASE PLATE _ ANCHORED TO CONC W/ 1/4" CONCRETE SCREW ANCHOR ••a"• (MIN. 1 1/4" EMBED) . 'a 6" MAX EACH SIDE OF POST AND 24" O.C. MAX I ° i=--6 FRONT VIEW CP-1 CORNER POST TO CONCRETE DETAIL A-4 SCALE: NTS V V f oC 1 N LU al - Q �o E 0 0 Wz. V) ILL, to Q Z 6 J` w f 2cp r( Z 1 O Gnn = f Z ED s ( V) V) V) M W Do = 2� v 0 c7 Q Q LL b Z U �7 Of �UjW Q Q 7 d = In F- O. co It LL. DRAWN BY EL DATE DRAWN 02/12/13 REVISION SHEET NO: A-4