HomeMy WebLinkAboutSUBMITTED PAPERSr
✓°
n , /-1
Date: , , l Fee Due: 11/ I Receipt# �/ (� / !—Permit # —�
Planning & Development Services
Building & Code Regulations Division
2300 Virginia Ave.
Fort Pierce, FL 34982
(772)462-1553
SPECIALTY PERMIT APPLICATTOIS
❑ .Electrical ❑ Plumbing 0 HvAC ❑ Fence
• Shed ❑ Demolition ❑ Gas ❑ Siding
Seepage 2 for instructions and additional paperwork requiredfor specialty permits
1. Locaiion/Site Address: __- 7
2. Parcel ID. Number: / �/ 3 ` j ��✓ — +'3 c°`oi� Jr
Office Use
Only
Section
Township
Range
Map Page
Zoning_
Land Use
Initials, '
3. Complete Description of Projector Rork:
t�t�`°J ll_L `(��Q�..L� lii �i7 ��� t•7f7/J�.�.i� �` ✓t% •'T/-'."'!7".'� i(%/
4. Owners Information 5. Contractors Information
Name: .r1I>"r�r,°}-f-�`/`�,�-��a30�; FLReg/Cert#:
Address: ,� "' S r Zi ':'�y S%' ? f' h i:% County Cert#:
City: A'e, 7 "41bz r--D.s/ State: Business Name: � � (y �;i/y 9. 7 (' e"; �'o 6
Zip: - 3 316- Phone: •j2�/ -�28� 21 Z Phone: SVY -.%%Fag: J&/ -9 V-1
6. Value of Construction: S 3 0
OWNER'S AFFIDAVIT: I certify that all of the information contai 's application is correct and that all work will be -done in
compliance with all.applicable laws.regVATU4RZE
struction and zoning.
PRINT -OWNER OR CONTRACTOR NAME OF OWNER OR CONTRACTOR
STATE OF FLORIDA, COUNTY OF �i` r✓' �J ec,c J
ACKNOWLEDGED BEFORE ME THIS DAyOF_t';�Ce w , 20Z3_ BY OYh'�
WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED
AVIATURE
IFICATION.
SPR - CHRISTINA WOLD
✓i c�Jl �! _ Notary Pu6*1 State of Florida
OF NOTARY TYPE OR PRINT NAME OF NOT ? x , • M
y Comm. Expires Jul 8, 2014
COMMISSION NUMBER eZ r7/ /� '�rFOFFLOP% Commission # EE 7193
Bonded Through National Notary .
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WIT11 YOUR
'LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00
Revised 04/26/2010
AC Search Page 1 of 1
OR AC Search
Eli Home Modify E@],Euport
Double dick on a row to viewtprint AHRI certificate.
RI certificates are not available for Obsolete AC and HP equipment.
isciaimer: Indoor Coil Air Quantity is used for standard ratingftest purposes only. Actual values may very depending on the
installation. Please refer to the manufacturer's installation instructions for proper setting of indoor Wil air guar
e energy efficiency ratings on the EnergyGuide labels provided below were determined per Federal Trade Commission requirements and Department of Energy standard tests of condenser models combined with the most common
gerent indoor components. Print the AHRI certificate in order to view tha ratings of a specific combination.
Model Status of 'Active' means models are currently In production. 'Discontinued' means that the manufacturer has elected
to stop producing, yet stock is still available. 'Obsolete' means that the manufacturer is required to stop manuh
Programs.
Outdoor Unit
Indoor Unit Cooling
AHRI
Certified
Model
Manufacturer
Trede/Brend
Series
Manufacturer
Model
Manufacturer
Model
Indoor
Coil Air
Indoor
Cod Air
Indoor
Col Air
Furnace
Capacity
EER
SEER
IEER
Phase
AHR
Refs
Status
Type
Name
Name
(Mix -Match)
Quantity
Ouwfiw
Quantily3
Model
(Bluh)
Type
COMFORT
3457532
Discontinued
Systems
CARRIERAIR
CONDITIONING
SERIES
PURON
CARRIER AIR
CONDITIONING
24ABB324
(A,"31
FF1ENPg25
50g
23g0g
11.50
14.0g
1
RCU
-A-
AC
CB
Now displaying records 1 - 7 of 1 total
Home I Corded Us IT' —end Conditions License AHRI Dimaory Deb I Help wdh this Site
Capydght ®2g13 Ak-Conditionmg, Heating, end Ref igembon Institute. AIt fights reserved.
ka� OJO
ST. LUCIE CO DING DIVLSION
REVIEWED FOR OMP
REVIENNTD BY
DATE !I-(, '/ Y
PLANS AND PERMIT MUST BE KEPT ON JOB
OR NO INSPECTION WILL BE MADE.
http://www.ahridirectory.org/ahridirectory/pages/ac/defaultSearch.aspx 12/19/2013
r
AwQ
AL)i dewy f-7//j 70-2
D i'A,
if
2: -f /11
girhl F
Olt5-.f--r
J1
L tl<
no�
elf 69 Fen
Ito
.3
al�
nhvac - Residential & Liaht Commercial: HVAC Loads
�"
Elife Software Development; Inc'.
Engineered Air, LLC
Roig Residence'
I Pompano Beach, FL 33064
Page 3a
S stem 1 Room Load Summary
Htg Min Run Run
Clg Clg Min Act
Room
Area Sens Htg Duct Dust
Sens Lat Clg Sys'
No Name
SF Btuh CFM SizeMMWIM=BtuIJjMPt7uh
CFM CFM
--Zone 1---
_ 1 Whole Unit
1,0_53 8,478 110 7-6 485
14,653 5,370 667 667
System 1 total
_
1,053 8,478 110
14,653 5,370 667 667
System 1 Main Trunk Size:
10x13 in.
Y
Velocity:
738 ft./min
Loss per 100 ft.:
0.105 in.wg
Coolin S stem Summa
Cooling Sensible/Latent Sensible
Latent Total
Tons S lit„ Btuh
NNWBtuh Btuh
Net Required:
1.67 73% / 27% 14'653
5,370 20,023
Actual:
1.92 , 75% / 25% 17,250
5,750 23,000
E`°'i mentData
Heating System
Cooling System
Type:
Electric Resistance
Standard Air Conditioner
Model:
5 KW
24ABB324(A,W)31
Indoor Model:
FF1 ENP025
Brand:
CARRIER AIR CONDITIONING
Efficiency:
0%
14 SEER
Sound:
0
0
Capacity:
0 Btuh
23,000 Btuh
Latent Capacity:
n/a
5,750 Btuh
AHRI Reference No.:
n/a
3457532
This system's equipment was selected in accordance with,ACCA Manual'S.
Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain:
14,653 Btuh, Lat. gain: 5,370 Btuh, Sen. loss: 8,478 Btuh, Entering clg. coil DB: 75F, Entering cig. coil WB: 62.5F,
Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 667
CFM, Req. htg. airflow: 110 CFM
S:\ ...\Roig Residence Port St. Lucie.rh9 ' Wednesday, December 18, 2013, 1:05 PM
+ Kesloenuai ik ugnt t ommercaaj nvm, LOGOS wite SOftWare Uevelol
ered Air, LLC Roig
Pro ed Report
Project Title:
Designed By:
Project Date:
Client Name:
Client Address:
Client City:
Company Name:
Company Representative:
Company Address:
Company City:
Roig Residence
Sam Vititoe
Monday, November 11, 2013
Fernando & Melissa Roig
4250 N Hwy A1A Unit 702
Port St. Lucie, FL 34949
Air American Service
Sam Vititoe
1310 S Killian Drive # 109
Lake Park, FL 33403
Desi n DataINNOWN
1111AM
Reference City:
Fort Pierce, Florida,
Building Orientation:
Front door faces West
Daily Temperature Range:
Medium
Latitude:
27 Degrees
Elevation:
25 ft.
Altitude Factor:
0.099
Outdoor
Outdoor
Outdoor
Indoor
Indoor
Grains
Dry Bulb
Wet Bulb
Rel.Hum
Rel.Hum
Dry Bulb
Difference
Winter: 42
39.4
n/a
n/a
70
n/a
Summer: 90
78
59%
50%
75
61
Total Building Supply CFM: 667
CFM Per Square ft.: 0.633 .
Square ft. of Room Area: 1,053
Square ft. Per Ton: 631
Volume (fP) of Cond. Space: 9,477
B'u`ildin' Loads
_ _ „
Total Heating Required Including Ventilation Air:
8,478
Btuh 8.478 MBH
Total Sensible Gain:
14,653
Btuh 73 %
Total Latent Gain:
5,370
Btuh 27 %
Total Cooling Required Including Ventilation Air:
20,023
Btuh 1.67 Tons (Based On Sensible + Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturers performance data at
your design conditions.
S:\ ...\Roig Residence Port St. Lucie.rh9 Wednesday, December 18, 2013, 1:05 PM
Roig Residence
HVAC Load Calculations
for
Fernando & Melissa Roig
4250 N Hwy Al Unit 702
Prepared By:
Sam Vititoe
Air American Service
1310 S Killian Drive # 109
Lake Park, FL 33403
Wednesday, December 18, 2013
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 80
The lower the EnergyPerformance Index, the more efficient the home.
4250 N Hwy Al Unit 702, Port St. Lucie, FL, 34949-
1. New construction or existing
Existing (Projecte 9. Wall Types
Insulation
Area
2. Single family or multiple family
Multi -family a. Concrete Block - Int Insul, Exterior
R=4.1
522.00 ft2
b. N/A
R=
ft2
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
2 d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No a. N/A
R=
ft2
6. Conditioned floor area (ft2)
1053 b. NIA
R=
ft2
7. Windows— Description
Area c. N/A
R=
ft2
a. U-Factor. Sgl, U=1.30
76.70 ft2 11. Ducts
a. Sup: Whole House, Ret: Whole House, AH: Whol
R ft2
6 100
SHGC: SHGC=0.64
b. U-Factor. Sgl, U=1.06
67.50 ft2
SHGC: SHGC=0.56
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2 a. Central Unit
23.0 SEER:14.00
SHGC:
d. U-Factor. NIA
112
13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
17.1
COP:1.00
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
0.603
8. Floor Types Insulation Area 14. Hot water systems
a. N/A R= ft2 a. Electric
b. N/A R= ft2
c. N/A R= ft2 b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant fe ures
Builder Signature: ZvIQ Date: -d -2 -
Address of New Home: l f5'o A) i foy A(4 �Da City/FL Zip: fw.y Vyn 31a"
Cap: 40 gallons
EF: 0.92
Pstat
ty D tHE Sr
� `err' �.�
rnrrr's`�'' •4, oo;;;,a1�� a to
4f
0D W6���
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge@ USA - FlaRes2010 Section 405.4.1 Compliant Software
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 4250 N Hwy A1A Unit 702 PERMIT #:
Port St. Lucie, FL, 34949-
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace' is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
he considered ducts or pleniim chambers, shall he constructed d
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters,
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds' Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
12/18/2013 12:43 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
HeatinHJan
Feb
HFeb
Mar
Mar
Apr
f ; Apr
I
May
May
X Jun
Jun
JUI
Jul
ri
Aul
rI Aug
Se
Se;
[ ]Oct
[ ] Oct
Nov
MNov
Dec
Dec
Ventin Jan
Feb
X Mar
[X] A r
May
Jun
Jul
Aug
Se
[X] Oct
Nov
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating(WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
'66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
12/18/2013 12:43 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
DOORS
#
Omt
Door Type Space Storms U-Value Width
Ft In
Height
Ft In
Area
1
W
Insulated Whale House None .4 3
6.7
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
v #
Wall
Omt ID Frame
Overhang
Panes NFRC U-Factor SHGC Area Depth Separation
Int Shade
Screening
1
2
3
4
W 1 Metal
W 1 Metal
E 3 Metal
E 3 Metal
Single (Tinted) Yes 1.06 0.56 24.0 ft2 6 ft 0 in 2 ft 0 in
Single (Tinted) Yes 1.06 0.56 12.0 ft2 6 ft 0 in 2 ft 0 in
Single (Tinted) Yes 1.06 0.56 31.5 ftZ 8 ft 0 in 12 ft 0 in
Single (Tinted) Yes 1.3 0.64 76.7 ft2 8 ft 0 in 1.33 ft 0 i
None
None
None
None
None
None
None
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess
0003 828.6 45.49 85.55 .225 5.246
HEATING SYSTEM
#
System Type
Subtype Efficiency Capacity
Block
Duds
1
Electric Strip Heat None COP: 1 17.1 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype Efficiency Capacity Air Flow SHR Block
Duds
1
Central Unit
None SEER: 14 23 kBtu/hr 690 cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type
SubTpe Location EF Cap Use SetPnt
Conservation
1
Electric
None Whole House 0.92 40 gal 50 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC Collector
Cert # Company Name System Model # Collector Model # Area
Storage
Volume
FEF
None None
ftZ
DUCTS
#
- - Supply - - — Return --- Air CFM 25 CFM25
Location R-Value Area Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1
Whole House
6 100 ft2 Whole House 10 ftZ Default Leakage Whole Hou (Default) (Default)
1 1
12/18/201312:43 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
PROJECT
Title:
Roig Residence
Bedrooms: 2
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1053
Lot #
Owner:
Fernando & Melissa Roig Total Stories: 1
BlocklSubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
4250 N Hwy Al Unit 7
Permit Office:
Port St. Lucie
Cross Ventilation:
County:
St. Lucie
Jurisdiction:
661200
Whole House Fan:
City, State, Zip:
Port St. Lucie ,
Family Type:
Multi -family
FL. 34949-
New/Existing:
Existing (Projected)
Comment:
CLIMATE
v
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST LUCIE CO INTL FL ST LUCIE_CO_INTL 2 39 90
70
75 722
58
Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1053 9477
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled
Heated
Mole House
1053 9477 Yes 4 .
2
1 Yes
Yes
Yes
ROOF
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
V #
Type
Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Flat
Concrete 0 ft2 0 ft2 Medium
0.4
No 0.9
No 1
4.8
ATTIC
J#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
No attic
Unvented 0
0 ft2
N N
WALLS
nmt
Adjacent
TO Wall Type
Space Cavity Width
In Et
Height
In
Sheathing Framing Solar
Area R-Vali- on
Frar
,
Below
1 W
-Et
Exterior Concrete Block - Int InSUVhole House 4.1 25 0 9
0
225.0 ft2 0.4
0 0.4
0
— 2 S
Exterior Concrete Block - Int InslNhole House 4.1 8 0 9
0
72.0 ft2 0.4
0 0.4
0
3 E
Exterior Concrete Block - Int InSUllhole House 4.1 25 0 9
0
225:0 ft2 0.4
0 0.4
0
12/18/2013 12:43 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Roig Residence
Builder Name:
Street: 4280 N Hwy A1A Unit 702
Permit Office: Port St. Lucie
City; State, Zip: Port St. Lucie , FL , 34949-
Permit Number.
Owner: Fernando & Merissa Roig
Jurisdiction: 661200
Design Location: FL. ST LUCIE CO_iNTL
1. New construction or existing Existing (Projecte
9. Walt Types (522.0 sgft.)
Insulation Area
2. Single family or multiple family Multi-fami)y
a. Concrete Block - lnt Insul, Exterior
R=4.1 522.00 ft=
b. NIA
R- ft2
3. Number of units, if multiple famr7y 1
c. NIA
Ra IV
4. Number of Bedrooms 2
d. NIA
R= ft=
10. Ceiling Types (0.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. NIA
R= ft'
6. Conditioned floor area above grade (ft2) 1053
b. NIA
R= IF
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft=
11. Ducts
R f?
7. Windows(144.2 sgfL) Descriptlon Area
a. Sup: Whole House, Ret: Whole House, AH: Whot 6 100
a. U-Factor. Sgl, U=1.30 76.70 f12
SHGC: SHGC=0.64
b. U-Factor: Sgl. U=1.06 67.50 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.56
a. Central Unit
23.0 SEER.14.00
c. U-Factor. NIA ft2
SHGC:
13. Heating systems
kBtulhr Efficiency
d. LI-Factor. N/A ft'
a. Electric Strip Heat
17.1 COP;1.00
Area Weighted Average Overhang Depth: 7.501 ft.
Area Weighted Average SHGC: 0.603
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Fluor Types (0.0 sgft.) Insulation Area
EF: 0.920
a. NIA R= fP
b. Conservation features
b. NIA R= 11'
None
c. N/A R= fF
1s, credits
Pstat
Total Proposed Modified Loads: 23.88
Glass/Floor Area: 0.137
PASS
Total Standard Reference Loads: 29.78
1 hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Review of the plans and
specifications covered by this
��' E�
Code.
calculation indicates compliance
f�
PREPARE BY: G►Re 6 powfiS Icy
with the Florida Energy Code.
Before construction is completed
'A CA L i 4
DATE. 01 _.
this building will be inspected for
compliance with Section 553.908
#
1 hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
71 we
OWNERIAGENT: _
BUILDING OFFICIAL: .
DATE:
DATE:--
..
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 403.2.2.1.1.
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
12/18/2013 12:42 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5
l
FRAME ASSEMBLY & UNIT TIE -DOWN DETAILS: PROBI1crRRVWymom
(2)1" WIDE x 14GA (0.070") ASTM p�I1�yy•�•
-BEAM ® A-653 FU=90KGALV STEEL ANGLE 7M7 I PI�
„ -. (CVTD-1 BY MIAMI TECH) OR (2) 1' By Q [n gM S
CHANNELTO TUBE W/ ^1" 1° WIDE 0.088"THICK 5052-H32 eY6�
V4 FULL PERIMETER WELD �' T ALUMINUM CLIPS (CUED-2 BY MIAMI p l y W 7 P U
•C' CHANNEL 22 (0.0299" Q Q / TECH), UTILIZE (2) MIN. PER CORNER. Z u w
yPROV[DE FILLET WELD MIN. STEEL A/C
y, FOR FULL VISIBLE HO SING UNtr FASTEN CLIP VERTICAL LEG To 22 GA (0.0299' < y! 3 '•
PERIMETER OF PIECE MIN.) STEEL HOUSING WITH (4) #14 SAE GRADE 2 aJn�( $ m w A
® TO PIECE O Q MIN. SHEET METAL SCREWS PER CUP. FASTEN CLIP Z
HORIZONTAL LEG TO I -BEAM RAIL WITH (1) #14 W 444111 '�
Y,20x%' GALV. BOLT M % SAE GRADE 2 MIN. SHEET METAL SCREW CENTERED N 3
TIGHTEN TO REFUSAL ABOUT LEG.
' SQUARE TUBING ®,® I -BEAM ISOLATOR PADS BEYOND o C. '
Doi
ROUND TUBING (D (BY OTHERS). MIN. 4 PER a
UNIT
i FRAME ASSEMBLY DETAIL r2i'� A/C UNIT TIE -DOWN DETAIL
DETAIL g SCALE: 3'-1'-0"
3'x3"xY."xZ%' LONG Z
f 6063-76 ALUMINUM ANGLE
22 GA (0.0299' 2" AT EACH CORNER
MIN.) STEEL A/C 7d
HOUSING UNIT ! , • / _ n ti g
U 3'
FASTEN ANGLE VERTICAL LEG TO 22 GA (0.0299" LLI a 0' a o
MIN.) STEEL HOUSING WITH (4) #14 SAE GRADE 2 ~ 3 z u
%. MIN. SHEET METAL SCREWS, FASTEN ANGLE fy z M i F
MAX HORIZONTAL LEG TO I -BEAM RAIL WITH (2) #14 I ?2
SAE GRADE 2 MIN. SHEET METAL SCREWS ¢ m
...yyy I -BEAM
ISOLATOR PADS BEYOND (BY z
OTHERS). MIN. 4 PER UNIT
A/C UNIT TIE -DOWN DETAIL
g scALE:3^=r-o^
NO : UNIT TIEDOW N DETAILS MAY ALSO
BE USED TO ANCHOR THE UNIT TO THE 5 9�R�
S PORT ANGLE SHOWN ON SHEET 10. a g i l
(I. I -BEAM CAN BE SUBSTITUTED WITH �g
_ A GLE SUPPORT AS BASE MATERIAL) 22 GA (0.0299" TWO y."O S.S. THRU I d d d C pEEE
f MIN.) STEEL A/C BOLTS WHERE A\C UNIT 4a
1"x 22 GAGE, A36 MEN. A/C UNIT HOUSING @@ g A GALVANIZED STRAP W-90° o HOUSING UNIT FASTEN A/C FRAMING 71 K
TWIST B PER UNIT. I EACH 0°T045° a DIRECTLY TO I -BEAM W/
SIDE OF EACH CORNER. MAX, (2);VO BOLTS W/ 5/8"
GRADE 2 MW.. SMS TO A/C n i
FASTEN N(3)#14 SAE WASHER AND NUT @ B
EACH CORNER. ip
UNIT, SAE GRADE N
2 MIN. IN. SM SMS TO f-BEAM
4 ISOIATOR PADS BEYOND I -BEAM (D I -BEAM ISOLATOR PADS BEYOND. € g i g
(BY OTHERS) MIN. 4 PER MIN, 4 PER UNIT
W PMGM QAiMNi DffItESB
4 ALT. A/C UNIT TIE -DOWN DETAIL /71 ALT. A/C UNIT TIE -DOWN DETAIL iz-Mn-oi
g SCALE: 3"-1'-0" g SCALE: 3"-1'-0` 1scAM Iffs 104
PA6! DESCRIPTION:
9