Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS1 —OFFULUSE ONLY: Date: — ~Kj Fee Due;-`` Oy Receipt# q Permit # t PLANNING & DEVELOPMENT SERVICES SCANNED BUILDING & CODE REGULATION DIVISION BY 2300 V"ffginia Avenue Et. Pierce, FL 34982-5652 St. Lucid County 772-462-1553 1 APPLICATION FOR ALUMINUM STRUCTURES PERMIT ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: s�� ���4y�� 't!�/y✓ 1 i/��� _ _ 2. PROJECT NAME: 90-k M G(Loo e SITE PLAN NAME: 3. PROPERTY TAX ID #: 4. LEGAL DESCRIPTION (attach extra sheets if necessary): (Jo_jaa_ G 2v je S110(j l (G o aO _ 5. PLAT BK PAGE BLOCK LOT o96 6. PARCEL SIZE: ACRES/SQ FT. LOT DIMENSIONS 7. SETBACKS (ACTUAL) FRONT: N BACK: d 1 RIGHT SIDE: N G LEFT SIDE: 8. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) N = New SG = Slab on Grade SQUARE FEET OF TYPE OF CONSTRUCTION A = Addition SR = Raised Slab DMENSIONS CONSTRUCTION _ R = Rebuild WD = Wood Deck SCREEN ROOM 0 ❑ NEW EXISTING ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X -------- ~--- ❑ --CAT 1, 2 OR 3 SUNROOM ❑ NEW ❑ EXISTING X —--� ❑ ALUMINUM COMP. SHED ❑ NEW ❑ EXISTING X ❑ POOL ENCLOSURE ❑ NEW ❑ EXISTING X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X L-I ROOF SYSTEM OVER _ ❑ NEW ❑ EXISTING XA- MSTING ACCESSORY STRUCTURE OTTIEk: — ❑ NEw ❑ maefl JC x _❑ _ ❑ ALUM POOL FENCE Linear feet TOTAL SQUARE FOOTAGE OF CONSTRUCTION O 9. VALUE OF CONSTRUCTION: $— The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted \ PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 RevOV26/2010 OWNER INFORMATION NAME: _Lr��wa-�.a{ c�w� ►'hafts/!�/�n� _l�_ a-� �"e LS - -- - ADDRESS: __ _5 C, 7 5- 1 tza u e 1-e r2 S l J� CITY: r I. P..e a f� STATE: /- / ZIP�-- PHONE (DAYTIME): (l� 0 1-1 (o rd -1 7 k / EMAII,-. FILL IN NAME AND ADDRESS BELOW IF THE FEE SIl"LE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: PHONE (DAYTIME): L� CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT ff: NFAIN-9 ZIP ST. LUCIE COUNTY CERT #: 0 BUSINESS NAME: t**'16es /5 c�� � P QUALIFIER'S NAME: M e-,4 f L - ADDRESS: q 4 xz-r2'ts �. -- --- - CITY: _ _�� R C� STATE: _%'- A ZIP�- PHONE (DAYT04E): i+(_ 7a) FAX NO. _1-/(o-1/- 26 u 3 email: ARCHITECT/ENGINEER: --� t,-M L-------- ADDRESS: 13 63 O S Sf' S/►i1) , s"'''l �" �o/ _ CITY: C'- /.Pi0s /L tea_-/-e_V?- STATE: // • 21P 3 3 7 �o 0 PHONE (DAYTIME): Q) )tea - qb DU NOTE- IF APPIWA ILE, Si. BCON1-RACTOR AGREEMENTS MUST BE ATTACIIED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND $VAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. 1�r-2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) OFFICE USE ONLY SECTION /D TOWNSHIP RANGE �D MAP NO. Additional ZONING LAND USE LOT CVG % Permits R uired REPORT L4 3q BIMS FEE $ MISC FEES $ TOTAL FEES $ CODE BUILDING & ZONING REVIEW FRONT PLANS VALUE OF CONSTRUCTION REVIEW COUNTER ZONING SUPERVISOR EXAMINER VEGETATION USING ICC TABLE DATE COMPLETE I a I 4 �1 17� l� I "!� �� ��J • �� U%011' • N v CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAND NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. 1 farther certify that 211 the foregoing information is accurate, that no work or instaHation has commenced prior to the issuance of a permit and that all work shall be performed in complianee with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. 1 , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not exceed the footprint of the structure that was in existence prior to removal by the storms. Kza, A�- OWNER OR CONTRACTOR SIGNATURE STATE OF FLORIDA COUNTY OF S-7. LUC I E The foregoing instrument was acknowledged before me me this 7''' day of :'ANUAe.r , 201+ by —/ A1-7 K&csz_MA—RKs— who is personally known produced '-"to me, or who has Ny� CONTRACTOR SIGNATURE STATE OF FLORIDA COUNTY OF ST. LU C I E The foregoing instrument was acknowledged before me me this 7 44' day of J'rAN U A Ry by MA77'N rr-Uj__N1 AR Kam- — who is personally known '—� to me, or who has produced as identification. : vt; i DONALD M HOLMAN as identification. `° N DONALD M HOLMAN P7Y COMMISSION # EE126749 MY COMMISSION# EE126749F_XPIRES Sep20,2015 EXPIRE c_ NMber 20, 2015 �''�+��oNote sirv� ,con Signature ofNoGuy ''"' Si tureofNota d07 $9il�t53 � F1orld�Noh 9ervke,com !� R' UvIPORTANT NOTICES: TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/SLDR AFFIDAVIT. °a ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. ® WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. PLAN 1, VIEW SPECIPICA,'TION 1"11ECKLIS'T PLEASE PROVIDE ONE OF THE F011OWING: 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida -State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide to Aluminum Cons-iruction in High Wind Areas. ❑ 2 Sets of Detailed Plans: Designed in accordance with any Approved Manual per fs-489.113. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. All plans must be legible and must be designed.in Architect's Scale on pages which are 81/2" x 1 I" or larger. ® All relevant tables & details, if using a manual, must be properly highlighted and must match design checklists & drawings. The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. ® All elevations must be shown, including 4 h wall detail, dimensions and all material must be sized and identified. All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. All methods of fastening or other details which are relevant to the design must be identified on the Plans. e All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"1. w All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. ® All ridge beams and super gutter or fascia attachments must be identified. All roof pans or composite panels, with gauges and spans, must be sized and identified. All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2007, Chapter 20, including 2006 revisions. o Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (H) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with listeners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per ASCE-7, identified on the openings of all Plans. (M) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 and FBC 2002.6) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 0 wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. Y 1 Edward C Daniels Record: 1 of 1 Property Identification Site Address: 5675 TRAVELERS WAY SecfTown/Range: 10 :36S :40E Map ID: 34/10A Zoning: PUD Ownership and Mailing Owner. Address: PROPERTY RECORD CARD <<Prev Next » Spec.Assmnt 'faxes PatcelID: 3410-503-0031-000-8 Account #: 133150 Use Type: SF Res City/Cnty: Saint Lucie County Exemptions Permits Home Print C�6 Legal Description Edward C Daniels Mary Anne Daniels PALM GROVE S/D BLK A LOT 20 (0.12 AC) (OR 2521-2277) 5675 Travelers Way Fort Pierce FL 34982 Sales Information Date Price Code 3/23/2006 180500 00 10/18/2001 67000 00 2/12/1998 62500 00 1/12/1995 61300 00 Assessment 2013 Deed Book/Page 2013 Final: 62500 WD 2521 / 2277 Assessed: 62500 WD 1447 / 0233 Ag.Credit: 0 WD 1126 / 0949 Exempt: 38000 WD 0937 / 2233 Taxable: 24500 Taxes: 586.91 BUILDING INFORMATION Total Land and Building Land Value: 12000 Acres: 0.12 Building Value: 50500 Finished Area 1135 SgFt FAT1' APPQ`P Ex terior Features View: 0010 - Base RootCover. SD - Dim Shingle RoolStmct: HP - Hip ExtType: HC - HC YearBlt: 1994 Frame: - Grade: C - C Eff ffllt: 1994 PrimeWall: BS - CB Stucco StoryHght: 0010 - 1 Story No.Units: 1 SecWall: - Interior Features BedRooms: 2 Electric: MX - MAXIMUM PrmIntWall: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHffi: 1/213ath: 0 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet %A/C: 100 0/.Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qua]. Cond. YrBlt. No. Use Type Type Measure Depth 1 0100-SF Res BI -Site 1 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. 54 7 5 VZ A V C 11- 0VA Y F-f Piep-cm, rL EAST COAST ALUMINUM PRODUCTS, INC. 913 Edwards Road Fort Pierce, FL 34982 (772) 464-7600 283-S80 SCA L 6 ' Yl� = 110 MIN. SETBACK REQ, FRONT SIDES CNR SIDES REAR 16' ZNG. ?LAC) TECH. CONTRACTOR: East Coast Aluminum Products, Inc. Applicable Codes, Regulations, and Standards 1. The 2010 Florida Building Code. specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2005 Edition 3. ASCE 7-10. Wind Loads I. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category 1. 2. Basic Wind Speed, Table 1609C, State of Florida Debris Region & Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: VOLT =150 MPH, VAso =116 MPH 3. Exposure Category, Paragraph 1609.4.3: Exposure B 4. Building Category for Aluminum Structures, Paragraph 2002.6: Category TYPE II - ACRYLIC ROOM Foundation Design Existing concrete slab. No additional concrete footing or slab is required to resist the loads imposed upon the existing slab by the proposed construction if the existing slab is a minimum of 4" thick and in sound condition, free from structural cracking, spalling, or other deterioration. Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" x 48" x 0.024" composite panel Elite 2000, 1.0 density foam, Florida Product Approval Number FL 7561-112. Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the Florida Building Code, 2010 Edition, and any other applicable local codes and regulations. 2. The minimum wall thickness of aluminum extrusions shall be in accordance with the Florida Building Code, 2010 Edition and the 2005 Edition of the Aluminum Association Manual, but not less than 0.040 inches. 3. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Suncoast Architecture & Engineering, LLC. 4. Screen Material: Design based on 18/14 or 20/20 Better View. Any other material must be approved. 5. Fasteners are required to be SAE Grade 5 or better zinc plated. 5. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or # 12 screws 6" from ends and 12" center to center. 7. Door location shall be determined by contractor in the field. 3. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type 1,- ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/- I % - ASTM C 260 iv. Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after hatching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 9. The minimum nominal thickness of protector panels (kickplates) shall be an industry standard of 0.024 inches. 10. All lumber and plywood shall have grade marks and treatment identification and Shall conform to the following: a. Framing lumber shall be minimum no. 2 southern yellow pine and have a maximum moisture content of 15%. b. Pressure treatments shall be osmosalts, osmose k-33, womansalts or celcure, as recommended for the use condition. Pressure treated lumber shall be impregnated with a cca salt treatment in accordance with Es. tt-w-571 and bear the American Wood Preservatives Institute quality mark 1p-2. c. Wall Sheathing: APA rated Sheathing, thickness as indicated, Exposure 1. d. Aluminum members that are uncoated shall be separated from PT lumber by 309 felt paper, 10 mil polyethylene sheet or equivalent material. 11. Contractor shall provide Florida Product Approval information as to the exact window being utilized for this project, including manufacturers specifications, and installation methods for anchoring the submitted windows to Aluminum members and specific sizes as indicated on A -I. l2. Contractor shall provide any additional backing and anchors as required by the window manufacturers recommended procedures. 13. All flashing and weatherproofing shall be provided by the contractor. WIND SPEED AND EXPOSURE HAVE BEEN DETERMINED USING THE ADV. TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. EXISTING WALL .FRAMING 71-1 Opt II II 0I Xi i ACRYLIC III II to I I I I------ 2X3PB II Xi i to ACRYLIC fill II I1 X2__ II /D6S6 ST. LUCTE CdL-, TY BUf4DENC, D1ti1SJD- RE'KEWED FOR COI E REVIEW D B DATE PLANS �a D P ' a HT I THE KEPT OINJOB 'OR 1V0 a1Va'rE CI IO'N ,L BE INILAi ------------------------------- _____ r------------------------------ I I I I W I I EXISTING c a - SCREEN A-3 i i w o ROOM AND i i N I COMPOSITE ROOF g m o I I I A I A-3 I I I I --- - _ 3X2X0.050 EDGE BEAM Ir 12'-0" 11,5'-6» EXISTING WALL FRAMING ----- - ------ U U U I'M J tri�l J III J tr% IIX >' XII > XII >- X IIN X NCI X NII X N (D II' Q II Q II U O II II II II II II A-2 - 2W3---- II-----2-3---- II 2 3 I A-2 6'-0" 6'-0" 5'-6" 3y9a2aeI O Z c>, =„ U> z -7 t: 'JWZL�IC'i IND,O.WS SVA'U BE f�EQ WEDW9ND=SPEEDS ,IN (YXGE}S 0 75 MPH W/3 ECOND I 'TY FILE (;UP O I to O I to (0 I W W Z W 0 a ZUJ -J Z O W Q H z W Vl Z LL LU > a t] 0 LLJ O d N � W li n b � J I= Z W Q R go F- W zm vI W �m$� Q Z'a! O UI .Nm U�:; Z Z �3nN W m�,^.0 VI CZ M'ut VI Vf } W Q Q J W LLI QU � -J 00 0Zuoa� ao °LLu EB DATE DRAWN 12/26/13 SHEET NO: A-1 e > • y ALUMINUM MEMBERS DIMENSIONS ,,`�'�es L]]]j���� �a KICK PLATE NOTES: 09' P • • •� • • �+ HOLLOW SECTIONS 2 x 2: 2" x 2" x 0.046" 1/8" x 2" x 2" EXTRUDED I (2) #14 X 3/4" SMS 1. 2. 0.024 ALUM SCREW ALL CORNERS a �•' p 2 x 3: 2" x 3" x 0.050" ANGLE 5052 H-32 ALLOY EA SIDE 3. 100 B - 120 B WIND ZONES USExSMS 12" Q co 2x4: 2"x4"x0.050" I • 4. 120 C- 140BB WIND ZONES C � z 0 2 x 5: 2" x 5" x 0.050" 1 1/2" x 3" x 0.050" USE #8 x 5/8" SMS 8" C/C b C W (V r C RECEIVING CHANNEL 5. 140 C - 150 WIND ZONES F OPEN BACK SECTIONS " 6. USE #8 x 5/8" SMS 6" C/C SCREW GIRT, BOTTOM I x 2: 1 x 2" x 0.040" 7x-MINCONC ANCHOR EMBEDMENT RAIL & BOTH SIDES 1x3: 1"x3"x0.045" - - 7. MAX KICK PLATE HT = 36" .� 7 , �H SNAP SECTIONS 2 x 2 Snap: 2" x 2" x 0.045" �� I I o� • ` ` Q ' v� P 2 x 3 Snap: 2" x 3" x 0.050" SLAB /FOOTING - OPTION 2: poa' eft 2 x 4 Snap: 2" x 4" x 0.045" SEE PLAN • 0.040" x 1 1/8" x 2" x 1 1/B" pROF£ 910NA'L$EAL OPTION 1: RECEIVING CHANNEL SELF MATING (SMB) SIDE VIEW SIDE W/ (3) #10 x 3/4"INTO 2" x 2" x t/8" ANGLE EACH (4) #10 x 5/8" EACH SIDE I I GIRT EACH FACE & (3) 2 x 4 SMB: 2" x 4" x 0.044" x 0.100" #10 x 3/4" INTO UPRIGHT LLJ 2 x 5 SMB: 2" x 5" x 0.050" x 0.100" 2X6SMB: 2"x6"x0.050"x0.120" ----- ---- Z W 2 x 7 SMB: 2" x 7" x 0.057" x 0.120" (2) 3/8" DIA. CONCRETE EXISTING Z i1 2 x 8 SMB: 2" x 8" x 0.072" x 0.124" SCREW ANCHORS UPRIGHT - - - - I - - - - W Q Q1 2 x 9 SMB: 2" x 9" x 0.072" x 0.124" (2 1/4" CONC. EMBED) J 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" I I I Q a CHAIR RAIL MEMBER Z n Z �- MINIMUM FASTENER EDGE DISTANCE: 1/2" 1 12" x 3" x 0.050" 2X PATIO O MINIMUM FASTENER SPACING: 3/4" RECEIVING CHANNEL ANCHORED TO CONCRETE I EXTRUSION tA v wl 1/4" X 1 1/4^CONCRETE I Ln Z J W CONCRETE SCREW ANCHOR: _ SCREW ANCHOR I I LJ- � G SMIPSON TITEN HD OR EQUIVALENT - - 6" MAX EACH SIDE OF O W cr SHEET METAL SCREWS (SMS): POST AND za" O.C. MAX H 0 ITW / BUILDEX OR EQUIVALENT W FRONT VIEW " SECTION POST TO CONCRETE DETAIL (FP OR GIRT TO BEAM OR POST DETAIL }��B x 3" OR LARGER L A-2 SCALE: NTS SCALE: NTS W V � J . S _ -a e �Z" 1"x 2" O.B. FASTENED TO CORNER Q - (2) #14 x 3/4" SMS INTO DJ POST W/#12x11/2"SMS AT6"FROM TOP 8 BOTTOM RAILS. TYPICALLY @ W z ^ g m g 1/8" x 2" x 2" EXTRUDED I I I I I 24" O.C. Q Z w o w ANGLE 5052 H-32 ALLOY I 1 1/2" x 3" x 0.050" 1/8"x2"x2".EXTRUDED ANGLE 5052 � m m (7 = min w u • • RECEIVING CHANNEL CORNER POST I I I H-32 ALLOY EA CORNER W/ (2) #14 x 2" SMS INTO POST & (1) 3/8' DIA SCREW ANCHOR INTO U Z Z < f N W o c C C e " i.. °C 6„ I I CONCRETE V) � r- o LL J I CONCRETE u LL WOOD: ,c\ #10 x 3" WOOD SCREWS, 6L' 2 11C MEN CONC EMBEDMENT FROM GIRT & @ 12' O.C. SLAB / FOOTING ' tANCNOR 2 7/ N CONC '\\ CONC: SEE PLAN } EMBEDMENT [.1 1/4" DIA x 3" CONCRETE'NCHOR SCREW ANCHOR, 6" SLAB /FOOTING \ % /' I Y FROM GIRT & @ 24" O.C. _ SEE PLAN ., 0, Vi c i� \, I C� \ (4) 910 x 1 1/2" INTOT SCREW BOSS n } L 3! / I SIDE VIEW (1) 3/8" DIA CONCRETE SIDE VIEW Q �� • �` SCREW ANCHORS 2" CORNER POST W/ 1"x 2" @ Q J � - - - �` - (2 114" CONC. EMBED) (2) #14 x 3/4" SMS BACKSIDE UJ - i INTO POST 3/8" x LENGTH AS REQUIRED U W _2w� \: I I FOR 21/4" EMBED CONCRETE I I LLl W 0) ' 2" x 2" OR 2" X 3" HOLLOW SCREW ANCHOR INTO O Z 0_ M 1 SECTION GIRT I 1 1/2" x 3" x 0.050" CONCRETE w Q co ~ �\• RECEIVING CHANNEL - LJ a O lL i 1 ^ x 2^ ANCHORED TO CONC W/ 1 /4" CONCRETE SCREW ANCHOR DRAWN BY 1 1/2" x 3" x 0.050" , (MIN. 1 1/4" EMBED) EB RECEIVING CHANNEL a MAX " 6EACH SIDE OF POST AND 24" O.C. MAX DATE DRAWN ANCHORED TO CONC W/ 1/4" CONCRETE SCREWANCHOR 6. 12/26/13 (MIN. 1 1/4" EMBED) REVISION C-1 6" MAX EACH SIDE OF POST O.C. MAX 1X2 TO HOST STRUCTURE DETAIL AND 24" SCALE: NTS A-2 _ FRONT VIEW FRONT VIEW SHEET NO: DJ-1 DOOR JAMB TO CONCRETE DETAIL CP-1 CORNER POST TO CONCRETE DETAIL A-2 SCALE: NTS A-2 SCALE: NTS A-2 (4)#12x4"SMS W/ NEOPRENE WASHERS PER �' 'j - p •" • `� PANEL " •o •!>�. `!. 3" x 0.040" ALUM - � RECEIVING CHANNEL W/#12x3/4"LL TOPAND 0, BOTTOM AS END CAP - :. ` C . Z O FLASHING -INSTALL f W Z • � Lu ` - - - - 3" COMPOSITE UNDER EXISTING DRIP EDGE �- W ` ¢ PANEL - 3" x 0.040" EXTRUDED RECEIVER CHANNEL r v •• 'C ii„� 3" x 2" x 0.050" TOP RAIL- #12 x 3/4" SMS @ 12" • •.•` +:. NO ANGLE REQUIRED I TOP AND BOTTOM UNLESS SPLICED OR II I CORNER ATTACH w/ (4) - W/NEOPRENE WASHER rAa i; p� se 5n - I II II @ TOP SCREW ONLY PROLE §fbB1kLU'�L - #10x4"LG 2" x UPRIGHT SEE DWG. FOR W W UPRIGHT SIZE Z LLI 3" x 2" d TOP RAILw/ - -- ';.' _ •�"+:":c' Z Q 0 4"SMS - 4 #1 x _ _ _ _ _ - W rn INTO POST -- -- - - - - - - -- -> ITE PANEL ( 3" COMPOSITE LAG SCREWS o Q Q - 2"x2"x3"LG - --_ 2"x2"x3"LG <- _ ANGLE @EACH OVERHANG fi �o Zej x 1/8" ANGLE x 1/8" O CO z G w N Z "—� (4) #10 x 3/4" (4) #10 x 3/4" W W Q SMS INTO SMS INTO I SCREW BOSSES S-� 0 LuJ0 SCREW BOSSES COMPOSITE PANEL TO FASCIA DETAIL O. (A(2) INTO TOP RAIL (2) INTO TOP RAIL I I INTO POST I I A-3 SCALE: NTS (2) INTO POST (2) CONNECTION AT CORNER CONNECTION AT SPLICE W S 3 X 2 TOP RAIL CONNECTION TO 2 X UPRIGHT b U ry A-3 SCALE: NTS i o NftTA .� U AM �? 9 IFY oC Z = g FILL U Q�� W = $ I— (A W t ��1mZ.1m 4N U O Zpiz Z 3NN Q W osr^p EXISTING HOST WALL A Oa cn 06 �u�? 3" x 0.062" ALUM #10 x 3/4"SMS RECEW/ (2)I CHANNELVING #14 x 3/4"" SMS INTO W/ NEOPRENE FLASHING WASHER AT EACH SIDE OF BEAM & (2) 12" OC. EXISTING COMPOSITE . � � #14 x 3/4" SMS INTO POST 3" x 2" PB � ROOF PANEL I I LLI CONCRETE: I I Q _U LU LU ~ ii (2) 1/4" x 3" QUICKSET ANCHORS INTO WALL #10 x 3/4" SMS 1 1 3" x 2" PB U Q' 1 1/8" x 2 1/8" x 1 1/8" x 2" x 0.040" `i WOOD: 12" O C I I I 1 W J D= � W F- W 0) ALUM RECEIVING CHANNEL (2) 1/4" x 3" LAG SCREWS I I I O Z Lc) 0 cn W/ (4) # x 3/4" SMS EACH INTO WALL 3" x 0.040" EXTRUDED Q 1 J SIDE INTO BEAM H- CHANNEL I d U LL W I CONTINUOUS POST DRAWN BY EB S-3 COMPOSITE ROOF TO EXISTING ROOF DATE DRAWN A-3 ANTS 12/26/13 S-4 CROSS MEMBER TO POST CONNECTION REVISION A-3 SCALE: NTS Q _ S-2 BEAM TO HOST STRUCTURE ATTACHMENT DETAIL SHEET NO: A-3 SCALE: NTS A-3-