Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: RECEIPT: (A / ---) i I PERMIT NUMBER: PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION 2300 Virginia Avenue SCANNED Fort Pierce, FL 34982 BY (772) 462-1553 St. Lucie APPLICATION FOR REPLACEMENT OF Cq�n fy WINDOWS, SKYLIGHTS, SWING DOORS, SLIDING GLASS DOORS & OVERHEAD GARAGE DOORS 1. LOCATION/SITE ADDRESS: 2�530 �A1 AAex\ R CGS 9`p► 2. PARCEL ID NUMBER: 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: --rGCAS�oisJC1 OG� 4. TYPE OF STRUCTURE: SFR MOBILE HOME OTHER 5. OWNERS INFORMATION 6. Name: E k-xS,\-r\&, Mo- � �J )& Address: ty� 1—►\ C�1 �i�GS City: t� p\ C�Gt. State: EL- ) Zip: �RggG Phone: q (b6 " aq Email: CONTRACTOR'S INFORMATION FL Reg/Cert #: County Cert #: `(:D� 00-1 Business Name: C--'a�" y 7• Phone Number: `-i (DIO —% (paQ Email: COMPONENT ID. PRODUCT DESIGN PRESSURE PRODUCT APPROVAL # WINDOWS SKYLIGHTS SLIDING GLASS DOOR SWING DOOR MULLIONS OVERHEAD GARAGE DOOR 1-149 -11-150 (oc7 1 rNZ%A ka — 0\\O o 1 [] Attach 2 copies of the Product Approval with details to the product being used. VALUE OF CONSTRUCTION: $ Q C) C�J FEES DUE: OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance �with all applicable laws regulating construction and zoning PRINT OWNER OR CONTRACTOR/QUALIFIER NAME SIGNATURE OF OWNM OR5CONTT��UALIFIER STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THISy DAY OF , 20 \"-\ , BY WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED SIGNATURE OF NOTARY TITLE: NOTARY PUBLIC AS IDENTIFICATION. \\ WanKA Le.-e. eo`P?vP"", TIFFANYA.LEE TYPE OR PRINT NAME dF NOTARY * 'SgYAgPMMISSI0N # OD 885525 EXPIRES: April 26, 2014 COMMISSION NUMBER �l9T60FFiQV Bonded Thru Budget Notary Services NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Property Appraiser - St.Lucie County, FL Page 1 of 1 PROPERTY RECORD CARD Edwina Markowski Record: 1 of 1 —Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification VUCIEC�G2 Site Address: 8680 HIDDEN PINES RD ParcellD: 2323-701-0012-000-7 Sec/Town/Range: 23 :35S :39E Account #: 14177 f < Map ID: 23/23S Use Type: SF Res �. Zoning: AR-1 City/Cnty: Saint Lucie County Ownership and Mailing Legal Description Owner: Edwina Markowski HIDDEN PINES ESTATES BLK A LOT 12 (1.00 AC) (OR 3412-1797) Address: 8680 Hidden Pines Rd Fort Pierce FL 34945-3109 Sales Information Assessment 2013 Total Land and Building Date. Price Code Deed Book/Page 2013 Final: 155300 Land Value: 40400 Acres: 1 7/13/2012 195000 0001 WD 3412 / 1797 Assessed: 155300 Building Value: 114900 6/23/2009 195000 0001 WD 3103 / 0394 Ag.Credit: 0 Finished Area: 2190 SgFt 10/28/2002 195714 00 WD 1603 / 2070 Exempt: 155300 10/27/2000 165000 00 WD 1363 / 1097 Taxable: 0 11/6/1989 40000 05 WD 0662 / 2406 Taxes: 0 10/1/1987 29500 00 CV 0560/1768 1/1/1982 0 01 CV 0370 / 0148 L1111_t101t Itlt llei 9Nrwol L ............ --------- p'rno (]m) 21 7e n wo) Lem 24 gym] Exterior Features View: - RoofCover: SD - Dim Shingle RoofStruct: HP - Hip ExtType: HB - HB YearBlt: 1990 Frame: - Grade: B - B EffYrBlt: 1990 PrimeWall: FS - Frm Stucco StoryHght: 0010 -1 Story No.Units: 1 SecWall: - Interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmintWall: DW - Drywall FullBath: 3 HeatType: FHA - FrcdHotAir AvgHVFI: 1/2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No, Use Type Type Measure SWAV - RES POOL AVG Y 1 280 AV AV 1990 1 0100-SF Res 205 -Acres 1.01 PA01 - POOL DK-AVG Y 1 434 AV AV 1990 ENC2 - POOL ENC-AVG Y 1 714 AV AV 1990 DWC - Driv-Concret Y 1 1050 AV AV 1990 FEN4 - CHAINLINK 4' Y 1 420 AV AV 2002 Depth THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.pasle.org/paslc/pre.asp?prclid=232370100120007 1/6/2014 4 I MIAMI•DIADE MIAMI-DADE COUNTY Em PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamldndegoy/nern/ DAB Door Company, Inc. 12195 NW 98"' Avenue Hialeah Gardens, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: 91- 4" Wide x 16' high Steel Sectional Garage Door w/ Window Lite Option APPROVAL DOCUMENT: Drawing No. 01-09, titled "Sectional Garage Door", dated 02/01/2001, with last revision F dated 10/13/2011, sheets 1 through 5 of 5, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo, manufacturing address, model number, the positive and negative design pressure rating, indicate impact rated if applicable, installation instruction drawing reference number, approval number (NOA), the applicable test standards, and the statement reading `Miami -Dade County Product Control Approved' is to be located on the door's side track, bottom angle, or inner surface of a panel. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 11-0119.21 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 12-0110.06 Expiration Date: August 9, 2016 Approval Date: March 1, 2012 �0%Z Page 1 DAB Door Comnany. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 01-09, titled "Sectional Garage Door", dated 02/01/2001, with last revision F dated 10/13/2011, sheets 1 through 5 of 5,.prepared by AI-Farooq Corporation, signed and sealed by Javad -Ahmad, P.E. B. TESTS "Submitted under NOA # 09-0128.04" 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 4) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a DAB 824 24 GA Sectional Garage Door with Fixed Windows, prepared by Hurricane Engineering & Testing, Inc, Test Reports No. HETI-08-2149A/B, dated 06/27/2008, signed and sealed by Candido F. Font, P.E. "Submitted under NOA # 09-0128.04" 2. Test report of Tensile Test per ASTM E 8, Report No. HETI 08-T182, prepared by Hurricane Engineering & Testing, Inc., dated 12/23/2008, signed and sealed by Candido F. Font, P.E. "Submitted under NOA # 03-0210. 04" 3. Test report on Salt Spray (Corrosion) Test per ASTM B 117 of a painted G-40 steel panels, prepared by Celotex Corporation, Test Report No. 258592, dated 08/17/1998, signed by W. A. Jackson, P.E. C. CALCULATIONS "Submitted under NOA # 09-0128. 04" 1. Anchor verification calculations prepared by AI-Farooq Corporation, complying with F.B.0 2007, dated 12/19/08, signed and sealed by Humayoun Farooq, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Permitting, Environment, and Regulatory Affairs (PERA) P; 907-FI17,017- C rlos 1W. 11trera, P.E. Product Control Examiner NOA No. 12-0110.06 Expiration Date: August 9, 2016 Approval Date: March 1, 2012 E-1 DAB Door Comuany. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 08-0305.02, issued to SABIC Innovative Plastics, for their Lexan Sheet Products, approved on 04/24/2008 and expiring on 07/17/2013. 2. Notice of Acceptance No. 07-1016.07, issued to Insulfoam, LLC, for their Insulfoam Expanded Polystyrene Insulation, approved on 11/29/2007 and expiring on 11/29/2012. 3. Notice of Acceptance No. 07-1107.08, issued to Dyplast Products, LLC, for their Expanded Polystyrene Block Type Insulation, approved on 04/26/2007 and expiring on 08/27/2008. 4. Notice of Acceptance No. 07-0301.10, issued to Dyplast Products, LLC, for their Dyplast ISO -CI Polyisocyanurate Insulation, approved on 06/07/2007 and expiring on 01/11/2012. "Submitted under NOA # 05-0228 02" 5. Test Report on Accelerated Weathering Using Xenon Arc Light Apparatus Test per ASTM G155 of "PVC Extrusion Material", prepared by Hurricane Engineering & Testing, Inc., Report No. HETI 04-A002, dated 09/27/2004, signed and sealed by Rafael E. Droz-Seda, P.E. 6. Test Reports on Tensile Test per ASTM D638 of "PVC Extrusion Material", prepared by Hurricane Engineering & Testing Inc., Report No. HETI 04-T251, dated 11/29/2004 signed and sealed by 1. Ghia, P.E. 7. Test Report on Self -Ignition Temperature Test, Rate of Burn Test and Smoke Density Test of "REHAU non -foam PVC extrusion material", prepared by ETC Laboratories, Report No. 04-761-15019.0, dated 05/06/2004, signed and sealed by J. L. Doldan, P.E. F. STATEMENTS 1. Statement letter of code conformance to 2010 FBC and no financial interest, issued by Al-Farooq Corporation, dated 10/26/2011, signed and sealed by Javad Ahmad, P.E. Carlos M. Utrera, P.E. Product Control Examiner NOA No. 12-0110.06 Expiration Date: August 9,.,2016 Approval Date: March 1, 2012 E -2 DOOR HEIGHT CONSISTS OF e'-8' 2 SECTIONS 18" 2 SECTIONS 21" 6'-9' 1 SECTION 18' 3 SECTIONS 21" 7' 4 SECTIONS 21- 7'-.3' - - 7'-6" 5 SECTIONS 18" - 7'-9' 4 SECTIONS 18" 1 SECTION 21" 8' 3 SECTIONS 18" 2 SECTIONS 21" V-3" 2 SECTIONS 18" 3 SECTIONS 21" 1 SECTION 18' 4 SECTIONS 21" 8'-8' 5 SECTIONS 21' — 9' a SECTIONS 18' — 9'-3" 5 SECTIONS 18- 1 SECTION 21° 4 SECTIONS 18' 2 SECTIONS 21" 9'-9' 3 SECTIONS 18" 3 SECTIONS 21" 10, 2 SECTIONS 18' 4 SECTIONS 21' 10'-3' 1 SECTION 18" 5 SECTIONS 21" CO-9" 6 SECTIONS 21" — 10'-9" 6 SECTIONS 18" 1 SECTION 21' 11' 5 SECTIONS 18' 2 SECTIONS 21" 1V-3" 4'SECTIONS 19" 3 SECTIONS 21' 11'—B" 3 SECTIONS 18" 4 SECTIONS 21' 11'-9" 2 SECTIONS 18' 5 SECTIONS 21" 12' 1 SECTIONS IS' 6 SECTIONS 21' 12'-3" 7 SECTIONS 21" — 12'-6" 6 SECTIONS 18' 2 SECTIONS 21" 12'-9" 5 SECTIONS 18" 3 SECTIONS 21" 13' 4 SECTIONS 18" 4 SECTIONS 21" 13'-3" 3 SECTIONS 18" 5 SECTIONS 21" 13'-6" 2 SECTIONS 18" 6 SECTIONS 21' 13'-9" 1 SECTION 18" 7 SECTIONS 21' 14' 8 SECTIONS 21" — 14'-3' 6 SECTIONS 18" 3 SECTIONS 21' 14'-8" 5 SECTIONS 18" 4 SECTIONS 21" 14'-9" 4 SECTIONS 18" 5 SECTIONS 21" 15 3 SECTIONS. 18" 6 SECTIONS 21' 15'-3' 2 SECTIONS 18" 7 SECTIONS 21' 15'-6" 1 SECTION 1B" 8 SECTIONS 21' 15'-9" 19 SECTIONS 21-1— 1 1131 16 SECTIONS 18-14 SECTIONS 21° 7-1/2" X 3" X .071" GALV. STEEL \ END ROLLER HINGE y 14 X 5/8" SMS m o mo .158 DIA. W/ MINE 5 6"X 3"X0.1" STEEL PLATE WITH (2) #14 X 5/8" SMS O \ o 0 I 071" X 7-1 2" CENTER GALV. STEEL O W/ (4) #14GX 1/2" SMS LOCK 2/ DOOR '-T-1" W X .15" THK. LATCH IG LOADED SLIDE BOLT LOCK (BOTH SIDES) :NED W/ (4) # 14 X 1/2" S.M.S. MIN. LOCK ENGAGEMENT CONFORMS TO 1012 REGARDING GARAGE DOORS O m BRACKET BRACKET STD. LIFT' DOOR LOW HEADROOM DOOR OPTION 7-7/8" X 3-1/8" X .010" STEEL PLATE CENTER STILE WITH (4) #14 X 3/4" SDS OUTSIDE HANDLE END STILE LOCK BAR GUIDES INSTALLED ON END STILE WITH (4) #14 X 5/8" SMS u Q .18T X .6W LOCK BAR ENGAGES IN TRACK GENERAL NOTES ON EACH SIDE OF DOOR 1, THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE OUTSIDE KEYED LOCK REQUIREMENTS OF THE FLORIDA BUILDING CODE 2010 EDITION INCLUDING LOCK BAR LOCKING SHOWN HIGH VELOCITY HURRICANE ZONE. ALTERNATE TO LOCKS SHOWN ABOVE E ANCHORS SHALL BE AS LISTED. SPACED AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 3. ALL BOLTS, NUTS AND WASHERS SHALL BE ZINC PLATED CARBON STEEL. 4. ANCHORING OR LOADING CONDITIONS OTHER THAN THOSE SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL. 5. A LOAD DURATION INCREASE 15 USED IN DESIGN OF ANCHORS INTO WOOD ONLY. TOP FIXTURE 5-1/2" X 2-3/4" X 0.1" V R STEEL PLATE WITH ONE 5/16-18 MS W/ NUT m FASTENED TO END STILE WITH OPTIONAL DOOR VIEWER m 0j (6) #14 X 3/4" SELF DRILLING SCREWS TO BE INSTALLED AT CENTER STILE Z n o CENTER STILE 0 co F Qg IL p0 M a&� l _ C aao e . B � tE5� aw3[L 0m J �0 00 Q��f . o� co 0 O 0 M O M uj I 0 a� N zmNb — — — I — — row 1 — — — — — — = C tnrno I 13� b OPTIONAL VENT L y A 0 0 �s N (3) 5" WIDE AT 7" O.C. MAX. OPTIONAL FLUSH FACE U O Z OPENING AREA NOT TO EXCEED WOOD GRAIN DESIGN 120 SQ. IN. COLONIAL DESIGN V) J d MAX. DOOR WIDTH O N = F INSIDE ELEVATION RAISED PANEL EMBOSSED DOOR ��Rgo DAB DOOR MODEL 824 q E I � R MAX. SIZE 9'-4" WIDE X 16'-0" HIGH o . � @ FL, THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT O Engr. JAVAD'� PRODuctREV19E0 q CIVIL r oompty6)B ult P1orMl ? RA. -PE p 70592 . n .•CAN. J538 A�Ippe�p tpp No Z�/��•a,� .. �` ,) 8 MProduct Caned drawing 01-09 sheet 1 of 5 FOR CONNECTION OF WOOD BUCK TO MASONRY SEE NOTE ON SHEET 4 SOUTHERN PINE .. 0.55 S.G.J. EDG DUST.: IL1 1/2" MIN. 1-3/16" 1.9" X 2.19" X 3.3" X .102" STEEL TRACK BRACKETS SEE SHEET 3 FOR SPACING .024" STL PANEL OUTSIDE OF D t6ll STEEL TRACK BRACKET FASTENED SOLID BRASS DOOR VIEWER TO WOOD JAMB WITH BY 'SCHLAGE SECURITY HARDWARE' 5/16" X 1-5/8" LAG SCREW (FULLY THREADED) INSTALLED IN 9/16" DIA. HOLES IN CENTER STILE ONE PER BRACKET POSITIONED AT EYE LEVEL OPTIONAL STOP MOULDING BY DOOR INSTALLER #14 X 5/8" SMS 6 PER HINGE 3(4" X 2" X 2-1/2" X 18 GA. ND STILE, CONNECT TO PANELS 1/2" X 1-3/4" X .059" FORMED STEEL FLAPS AND 3/18" ALUM F GLUED TO PANEL AND SECURED TO SEE DETAIL A END STILE WITH 3/16" POP RIVETS 0 12" O.C. 1-7/8" X 2-5/8" X .045" STEEL CENTER STILE, GLUED AND RIVETED TO PANEL W/ (4) 3/18' RIMS POP RNE75� 4/4H NGE 8" S.M.S. 2-1/8' X 1" X .078" GALV. STEEL TRACK FASTENED TO TRACK PLATES 7/16" PUSHNUT W/ %4 2EO .5 8& TLRUSS HD. OCK NUT INSTALLED ON ROLLER SHAFT 7-1/2" X .050" GALV. STEEL J CENTER HINGE SECTION B-B INTERIOR SIDE 24 GA. STEEL PANEL �r o �I 3/16" ALUM RIVETS Z � 0� n Q FLAPS BENT OVER PANEL 1 a J OXX " CL LL 1/2" PUNCHED HOLES (� O 0 4" D.C. / a 'o 0°'ao �'30°0 aWo ZIAo (y s In f I ,. J a Q J I � END STILE IY 00 ANCHORS: O o M A) 3/8' DIA, POWER -BOLT BY 'POWERS' W 2" MN. EMBED INTO CONCRETE Q 1-7/8" MIN. EDGE DISTANCE B) 3/8' DIA. HLC SLEEVE BY 'HI TI' C¢.0 Z ~ Z 1-1/4" MIN. EMBED INTO CONCRETE OR FILLED BLOCK Q� Do W y rn p I 1-5/8" MIN. EDGE DISTANCE INTO CONCRETE Z 2' 0_ e 4° MIN. EDGE DISTANCE INTO FILLED BLOCK F 3i O Z 0 U O EDGE CONCRETE fe - 3000 PSI MIN. —DISTANCE C-90 GROUT FILLED BLOCK Am 2000 PSI MIN. 0 In v b a, J O �2 I -q e. .: 1_ 3/16� I .• O IFC 0 g0 ANCHOR TYPE A OR B (1) PER BRACKET 4 46 $ g SEE SHEET 3 FOR BRACKET SPACING g 33 7-1/2" X 3" X .071 J \ END ROLLER HINGE 1.82" DIA. X .50" NYLON/STEEL ROLLERS W/ .44 DIA. X 4-1/4" STEM 1/4-20 SS BOLT & NUT 19. JAYnM.AHM,� . MOD=REVIND q o CIVIL 5 FLA. PE- y 70592 o C.A.N.3538 Aa>rploFae - 1 0.6 ., 0 n Sa. II. ;;i. •L. 'E7grIBY� Pr�aOmad drawing no. 01-09 N POP RIVETS 2-3/4" X 5-1/2" X 3° X .104" 5/10" X 1-5/8" LAG SCREWS INTO WOOD OR GALV. STEEL 5/16" SLEEVE ANCHORS RACK /TOP ROLLER BRACKET (DOUBLE) _ WITH 1-1/4" EMBED INTO MASONRY FASTENED W/ (6) # 14 X 5/8" S.M.S. _ 3 PER BRACKET 090 THK. GALV. STEEL ADJUSTABLE SLIDE FASTENED TO BRACKET 2-1/2" X 4-1/4" X 13 GA STEEL PLATES 5REWS ' X 3/4" HEX HEAD = = WELDED TO 1-1/2" X 1-1/2" X 14 GA ANGLE M. SCREWS &NUTS. WITH (4) 1/4-20A S. BOLT &STENED TO TNUTS \HORIZONTAL REINFORCEMENT 1/2" X 1-3/4" X .059" FORMED STEEL GLUED TO PANEL AND FASTENED TO VERTICAL STILES WITH (2) 3/16" POP RIVETS 2° X 5-1/2" X .104GAL%" FASTENED W/ (4) N 14 X EL 5/8" S.M.S. TOPP ROLLER BRACKET FOR LOW HEADROOM DOOR OPTION HORIZONTAL REINFORCEMENT 1/2" X 1-3/4' X .059" FORMED STEEL GLUED TO PANEL AND FASTENED TO VERTICAL STILES WITH (2) 3/16" POP RIVETS 5/16" MEETING RIB DIA. X .50" ROLLERS .44 DIA X 4-1/4" STEM OPTIONAL INSULATIONS EPS-EXPANDED POLYSTYRENE DENSITY T 1.05 PCF N.O.A. d07-1107.08 OR ISO-25 POLY-ISOCYANURATE DENSITY = 2.0 PCF N.O.A. #07-0301.10 OR DENSITY = 0.92 PCF N.O.A. 007-1016.07 14 GA GALV. STEEL ROLLER HINGES FASTENED W/ (4) #14 X 5/8" SMS MIN..024" ROLL FORMED STEEL PANEL DRAWING QUALITY G-40 MIN. YIELD STRENGTH = 34 KSI WITH PRIMER AND BAKED -ON POLYSTER PAINTED TOP COAT APPLIED TO BOTH SIDES OF STEEL 12 GA. GALV. STEEL BOTTOM BRACKET FASTENED W/ (4) #14 X 5/8" SMS BOTTOM SEAL .058 ALUM PLATE WITH 1/8' X 1' S.M.S. ® 48" O.C. AND RUBBER WEATHERSTRIPPING HORI'L. TRACK SUPPORT, CENTER SUPPORT REDD. ON DOORS EXAEEDING 8 FT. IN HEIGHT I A II A — J -- HORIZ. TRACK LENGTH = OPENING HEIGHT PLUS 12" 14 GA. GALV. STEEL TRACK ANGLE SPOT WELDED TO HORIZ. TRACK 2 X 2 X 1AT LL -1/2'HORIZ. WITH TWO WELDS AT 1-1/2" APART � ! FIRST AT 3" O.C. REST AT 9" O.C. CONNECTED TO FLAG BRACKET4" BOLT ANGLE AND TOBSPRING SHAFT GUIDE WITH UT (2) 1/4-20 X 5/8" BOLT &NUT z n - IP Q g 0 M 0 VERTICAL TRACK 2-1/8° X 1" X .080" SECTION A -A 0 8 r O p Q' Om m o 0 IL 4 1% 2 Qg343C LLzN n DOOR HEIGHT • SECTION HEIGHTS 1ST 2ND 3RD 4TH 5TH I BRAG B1 B2 B3 94 B5 B6 B7 B8 6'-0" 18" 18" 18" 18" N/A 1" 11-3/4" 23" 34" 45" 56" 67" - 6'-B" 21" 1B" 18" 21" N/A 1" 11-3/4" 23' 34" 45" 58" 87" - 7'-0" 21" 21 21" 21 N/A 1" 11-3/4" 23" 34' 45' S6" 67" - 7'-6" 18" 18, 18" 18" 18" 1" 11-3/4" 23' 34° 45" 56" 67" 78-1/4" 8'-0" 21" 18" 18" 18" 21" 1" 11-3/4" 23" 34° 45" 56" 67" 78-1/4" -SECTIONS ARE NUMBERED STARTING AT THE BOTTOM FOR DOORS MORE THAN 8 FT. HIGH, USE ADDITIONAL TRACK BRACKETS AT 10" O.C. 1 NN TED X RAC X WITH STEEL TRACK BRACKETS 2-3 16" HIGH CONNECTED TO TRACK WITH .0) 1/4" BOLTS & NUTS. 2 IFT m n m m TRACK CONFIGURATION VERTICAL LIFT HIGH LIFT STANDARD LIFT LOW HEADROOM DOUBLE TRACK Of DO 0 O M �7 La zz nD Li C y W O I Ix of O 0 .6 v OZ. V � to Ign JAVAD AHATAD .. ALODUCFRBVLSBD I o_ CMI. rODWyftw0dthe Fk" o FLA PE M 70592 aufl�yB Cpd! "+ I C.A.N. 538 Aa ga me No 12- ll& 06 o l) �, Z 2wZ a � 5 ( drowgi�g no. 01 1-09 WOOD FRAME BUILDING STUD WALLS OR DOOR OPENING (NOT BY DAB DOORS) SHALL BE FRAMED SOLID BY NOT LESS THAN (3) 2X6 PRESSURE TREATED GRADE 2 SYP OR BETTER WOOD STUDS. STUD WALLS TO BE CONT. FROM FOOTING TO TIE BEAM ENGINEER OF RECORD TO VERIFY ADEQUACY OF THE SUPPORTING STRUCTURE, TRACK SHALL BE SECURED WITH CONT. STEEL ANGLE TO PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN WITH 1/4" ULTRACON BY 'ELCO' WITH SPACING OF 20° O.C. INTO BLOCK WALL, WITH 2-1/4" MIN. EMBED 16" O.C. INTO 30DO PSI CONCRETE, WITH 1-3/4' MIN. EMBED 2-1/2" MIN. EDGE DISTANCE 1/4' TAPPER BY 'POWERS' WITH SPACING OF 14 O.C. INTO BLOCK WALL, WITH 1-1/2" MIN. EMBED 16" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 3' MIN. EDGE DISTANCE 3/8" CONFLEX BY 'ELCO' OR 3/8" LOT BY 'TIN'' WITH SPACING OF 24" O.C. INTO 3000 PSI CONCRETE, WITH 2-1/2° MIN. EMBED 2" MIN. EDGE DISTANCE 3/8" HLC SLEEVE BY 'HILTI' WITH SPACING OF 17° O.C. INTO BLOCK WALL, WITH 1-1/4" MIN. EMBED, 4' MIN. EDGE DIST, 18" O.C. INTO 3000 PSI CONCRETE, WITH 1-1/4' MIN. EMBED AND 2-1/2' MIN. EDGE DISTANCE THE BLOCK WALL CELLS SHALL BE GROUT FILLED AND REINFORCED WITH FOUR k 5 BARS EXTENDING INTO FOOTING AND INTO TIE BEAMS ALL BARS S LL BE CONTINUOUS FROM TIE BEAMS TO FOOTING. PREPARATION OF JAMBS BY OTHERS LAG SCREWS STEEL STRUCTURE BY OTHERS AT 12" O.C. MUST SUPPORT THE LOADS IMPOSED 8Y DOOR SYSTEM ° 5/16" DIA. BOLTS ,`o•. - rWITH WASHER & NT I AT 12" O.C. MA%. ANCHOR SPACING ANCHORS STRUCTURE 1 EMBED SPACING EDGE DIST. 3 8 HLC SLEEVE BY HILTI CONC. 1-1/4- 8° 1-5 8 3 8" HLC SLEEVE BY 'HILTI FILLED BLOCK 3 8" DYNABOLT BY ITW' CONC. 1-1 2 3 8" DYNABOLT BY 'ITW' FILLED BLOCK 1-1 2 8' 3-3 4 3 6 POWER -BOLT BY POWERS CONC. 2' 8' 1-7 8 3 8 SLEEVE -ALL BY SIMPSONS CONC. 1-1 2 8' 1 1-7/8- W 00 0 O O M N7 41 LJ 0 a� < Z I=- (N C9 — Z CONCRETE Pc - 3000 PSI MIN. O O 3 le a � v. C-90 GROUT FILLED BLOCK I'm = 2000 PSI MIN. U 0 Z = N LLJ U1 Y Lo N a 1-1/4' X 2-1/2° X 14 GA 1-1/2° 1-1/2' CONY. STEEL ANGLE I1-1/2' 12 GA. GALV. STEEL FLAT BRACKETS f3" LONG AT 12" O.C. IN DOOR OPNG. AT 18" O.C. ABOVE DOOR OPNG. CONNECTED TO CONT. ANGLE W/ (3) SPOT WELDS AT EACH SIDE 2-1_/B" X 1° X 14 GA. GAL . STEEL TRACK FAST((EN))ED//TO TRACK PLATES SL0TT2ED OI &XLOCCK NUT SS HD. ALTERNATE TRACK INSTALLATION moDucrafivrAD q a/ complying Widllhc Flmid! BWfdbg Colo o I ER�inkli eNo lZ 1 , By M ' F Comm drawing no. 01-09 etiv�c 10 DOOR PANEL 24 GA. (.024) STEEL MIN. DIA. WASHER (j8 X 3/4' SMS -® 3/8" FROM ENDS AND 7" O.C. MAX. (4) #8 X 3/4" SMS -0 1-3/8" FROM ENDS AND 6-1/2' O.C. MAX. .175 X ,062 DEEP GROOVE 1/4" POLYCARBONATE LEXAN BY SABIC INNOVATIVE PLASTICS NOA 008-0305.02. K .062 DEEP IE (4) Q8 X 3/4" SMS ® 1-3/8" FROM ENDS AND 6-1/2" O.C. MAX. ---,,{%8 X 3/4" SMS 0 3/B" FROM ENDS \ AND 7" O.C. MAX. `7/16" DL1. WASHER DOOR PANEL 24 GA. (.024) STEEL MIN. .500 W-r -250 * PLASTIC COMPLIES WITH I I SECTION 2612 OF FBC 2007 SEE EVIDENCE PAGE Z r00 0� p 1.765 1.725 Q E n 0 w n 4 0 0 ."1 21 MA3X. II I F^—.6GD c a 0. WDW. WIDTH .176 F"- 0 IL ¢ o_ W_ 18 1/8" * EXTERIOR FRAME RIGID PVC ONE PIECE INJECTION * INTERIOR FRAME RIGID PVC ONE PIECE INJECTION 0 '� Q 3 LL N 'm J g N d D.L.O. J = o aWf 1 — — 1 11 W-119- 311- 1 - 0_0 I �_ C m Ell INSIDE ELEVATION RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS #8 X 3/4" SMS C' 0 3/8" FROM ENDS 175 X .062 DEEP AND 4-1/2" O.C. MAX. GROOVE _ I . _. _._._._._._. ._._._._. _._._._. _. ngC JAVAD'AKMAD, _ _ _ _ _ _ _ _ _ _ G'Mpp L FLA. PE 70592 ---_____ .CAN.,353,8• DOOR PANEL v 24 GA. (.024) STEEL MIN. EXTERIOR 15/16' MIN. n.l. nvr. lV x 00 0 C) O M O M W U = a Z F- a0 W � N rn p I 0 03o U 0 z Lo ,n 0 .�2 YRODUE7XEVJSEDas ue with the Flow. Q No •0/!0 Glb o BY Centro, drawing no. 01-09 l S, . These Tables Are For GARAGE DOORS IN One and Two Family Dwellings Garage Doors Installed In Buildings with a Mean Roof Height of 30' or Less Located in Exposures B,C or D Table R301.2(4) . COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE-[PSF] 7160 EXPOSURE B 9' x 7' Door = + 26.7 - 30.2 ❑160 EXPOSURE B 16' x 7' Door = + 25.6 - 28.5 &0! C ' x ' ®o= o"'r=)�[32�.436?r6�'(1 story and max 15' EXPOSURE C 16' X 7' Door = + 31.0 - 34.5 mean roof height) ❑160 EXPOSURE C 9' x 7' Door = + 37.4 - 42.3 (2 story and max 30' ❑160 EXPOSURE C 16' X 7' Door = + 35.9 - 39.9 mean roof height) ❑160 EXPOSURE D 9' x 7' Door = + 39.3 -44.4 (1 storyand max 15' ❑160 EXPOSURE D 16' x 7' Door = + 37.7 -41.2 mean roof height) ❑160 EXPOSURE D 9' x 7' Door = + 44.3 - 50.2 ❑160 EXPOSURE D 16' x 7' Door = + 42.5 - 47.4 7150 EXPOSURE B 9' x 7' Door = + 22.8 - 25.8 ❑150 EXPOSURE B 16' x 7' Door = + 21.8 - 24.3 ❑150 EXPOSURE C 9' x 7' Door = + 27.6 -31.3 ❑150 EXPOSURE C 16' x 7' Door = + 26.4 - 29.5 ❑150 EXPOSURE C 9' x 7' Door = + 32.0 - 36.2 ❑150 EXPOSURE C 16' x 7' Door = + 30.6 - 34.1 ❑150 EXPOSURE D 9' x 7' Door = + 33.6 - 38.0 ❑150 EXPOSURE D 16' x 7' Door = + 32.1 - 35.8 ❑150 EXPOSURE D 9' x 7' Door = + 37.9 - 42.9 7150 EXPOSURE D 16' x 7' Door = + 36.2 - 40.4 ( 2 story and max 30' mean roof height) (1 story and max 15' mean roof height ( 2 story and max 30' mean roof height) (1 story and max 15' mean roof height) (2 story and max 30' mean roof height) Notes: ■ Secure existing bucks per the Product Approval or Design Professional Instructions prior to installing the door. Have product approvals available at the time of inspection. ■ Glazing in Garage doors must comply with R301.2.1.2 (Glazing must be impact resistant or shuttered) MIAMI- MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.mlamidade.gov/nera/ DAB Door Company, Inc. 12195 NW 98'h Avenue Hialeah Gardens, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Hurricane Master® Model 824/811 Steel Sectional Garage Door 16'-2" Wide x 16'- 0" High with Window Lite Option APPROVAL DOCUMENT: Drawing No. 02-21, titled "24 GA. Roll Formed Steel Sectional Garage Door", dated 09/10/2002, with last revision G dated 10/13/201.1, sheets 1 through 5 of 5, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo, manufacturing address, model/series number, the positive and negative design pressure rating, indicate impact rated if applicable, installation instruction drawing reference number, approval number (NOA), the applicable test standards, and the statement reading 'Miami -Dade County Product Control Approved' is to be located on the door's side track, bottom angle, or inner surface of a panel. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 11-0414.12 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 12-0110.14 Expiration Date: July 21, 2015 Approval Date: March 1, 2012 t1 !,1;7,)342°1 Page 1 DAB Door Company, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 02-21, titled "24 GA. Roll Formed Steel Sectional Garage Door", dated 09/10/2002, with last revision G dated 10/13/2011, sheets 1 through 5 of 5, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS "Submitted under NOA # 11-041412" 1. Test Report on Uniform Static Air Pressure Test, Loading and Forced Entry Test per FBC, TAS 202-94, of "DAB 824 Sectional Residential Garage Door" prepared by Hurricane Engineering & Testing Inc., Report No. HETI-07-4200, dated 05/02/2007, signed and sealed by Candido F. Font, P.E. 2. Test Report on Large Missile Impact Test per FBC, TAS 201-94 and Cyclic Wind Pressure Test per FBC, TAS 203-94, of "DAB 824 Sectional Residential Garage Door", prepared by Hurricane Engineering & Testing Inc., Report No. HETI-11-3204, dated 01/20/2011, signed and sealed by Candido F. Font, P.E. 3. Test Report on Tensile Test per ASTM E8-08 of "Sectional Residential Door (skin)", prepared by Hurricane Engineering & Testing Inc, Report No. HETI-11-T100, dated 01/21/2011, signed and sealed by Candido F. Font, P.E. "Submitted under NOA # 05-0228 02" 4. Test Report on Large Missile Impact Test and Cyclic Wind Pressure Test, of "Sectional Residential Door with Windows", prepared by Hurricane Engineering & Testing Inc., Report No. HETI 03-1328, dated 07/15/03, signed and sealed by Rafael E. Droz-Seda, P.E. 5. Test Report on Uniform Static Air Pressure Test, of "Sectional Residential Door" prepared by Hurricane Engineering & Testing Inc., Report No. HETI 03-1329, dated 07/15/03, signed and sealed by Rafael E. Droz-Seda, P.E. 6. Test Report on Tensile Test per ASTM E-8 of "Sectional Residential Door (skin)", prepared by Hurricane Engineering & Testing Inc, Report No. HETI 03-T078, dated 10/31/03, signed and sealed by Rafael E. Droz-Seda, P.E. "Submitted under NOA # 03-0210.04" 7. Test report on Salt Spray (Corrosion) Test per ASTM B 117 of a painted G-40 steel panels, prepared by Celotex Corporation, Test Report No. 258592, dated 08/17/1998, signed by W. A. Jackson, P.E. #�vZ/231201Z Carlos M. Utrera, P.E. Product Control Examiner NOA No.12-0110.14 Expiration Date: July 21, 2015 Approval Date: March 1, 2012 E-1 DAB Door Company, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS "Submitted under NOA # 11-0414.12" 1. Anchor verification calculations prepared by Al-Farooq Corporation, complying with F.B.0 2007, dated 04/07/2011, signed and sealed by Javad Ahmad, P.E. 2. Anchor verification calculations prepared by Al-Farooq Corporation, complying with F.B.0 2007, dated 12/19/2008, signed and sealed by Humayoun Farooq, P.E. "Submitted under NOA # 09-0128.02" D. QUALITY ASSURANCE 1. Miami -Dade Department of Permitting, Environment, and Regulatory Affairs (PERA) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 08-0305.02, issued to SABIC Innovative Plastics, for their Lexan Sheet Products, approved on 04/24/2008 and expiring on 07/17/2013. . 2. Notice of Acceptance No. 07-1016.07, issued to Insulfoam, LLC, for their 'Insulfoam Expanded Polystyrene Insulation, approved on 11/29/2007 and expiring on 11/29/2012. 3. Notice of Acceptance No.11-0926.07, issued to Dyplast Products, LLC, for their Expanded Polystyrene Block Type Insulation, approved on 11/10/2011 and expiring on 01/1.1/2017. 4. Notice of Acceptance No. 11-0926.06, issued to Dyplast Products, LLC, for their Dyplast ISO -CI Polyisocyanurate Insulation, approved on 11/10/2011 and expiring on 01/11/2017. "Submitted under NOA # 05-0228.02" 1. Test Report on Accelerated Weathering Using Xenon Are Light Apparatus Test per ASTM G155 of "PVC Extrusion Material', prepared by Hurricane Engineering & Testing, Inc., Report No. HETI 04-A002, dated 09/27/2004, signed and sealed by Rafael E. Droz-Seda, P.E. 2. Test Reports on Tensile Test per ASTM D638 of "PVC Extrusion Material', prepared by Hurricane Engineering & Testing Inc., Report No. HETI 04-T251, dated 11/29/2004 signed and sealed by I. Ghia, P.E. 3. Test Report on Self -Ignition Temperature Test, Rate of Burn Test and Smoke Density Test of "REHAU non -foam PVC extrusion material', prepared by ETC Laboratories, Report No. 04-76145019.0, dated 05/06/2004, signed and sealed by J. L. Doldan, P.E. F. STATEMENTS 1. Statement letter of code conformance to 2010 FBC and no financial interest issued by Al-Farooq Corporation, dated 10/26/2011, signed and sealed by Javad Ahm d, P.E. d 23 2o1Z Carlos M. U rera, P.E. Product Control Examiner NOA No.12-0110.14 Expiration Date: July 21, 2015 Approval Date: March 1, 2012 E -2 Ip 7-1/2" X 3" X .071" (D GALV. STEEL END ROLLER W/ (6) #14 X 5/8" SMS m 7-1/2" X 2-1/4" X 18 GA. GALV. STEEL CENTER HINGE W/ (4) #14 X 5/8" SMS LOCK 2/ DOOR 1' W X .15 THK. LATCH i r SPRING LOADED SLIDE BOLT LOCK (BOTH SIDES) FASTENED W/ (4) #14 X 1/2" S.M.S. 5/B" MIN. LOCK ENGAGEMENT CONFORMS TO B F8C 1012 REGARDING GARAGE DOORS .15B DIA. W/ MN 5 2-3/4"W X 5-5/8'H X .090" STEEL PLATE, 1-3/8" WITH (3) #14 X SELF DRILLING SC DOOR HEIGHT CONSISTS OF 6'-6" 2 SECTIONS 18" 2 SECTIONS 21' e'-9' 1 SECTION 18" 3 SECTIONS 21" 7 4 SECTIONS 21' - 7 -3" - - 7'-6" 5 SECTIONS 18" - 7'-9" 4 SECTIONS 18" 1 SECTION 21" 8' 3 SECTIONS 18" 2 SECTIONS 21" 8'-3" 2 SECTIONS 18" 3 SECTIONS 21" 8'-6' 1 SECTION 18' 4 SECTIONS 2V 8'-9" 5 SECTIONS 21" - 9' 6 SECTIONS 18" - 9'-3" 5 SECTIONS 18" 1 SECTION 21' 9'-6" 4 SECTIONS 18" 2 SECTIONS 21" 9'-9" 3 SECTIONS 18" 3 SECTIONS 21' 10' 2 SECTIONS 16" 4 SECTIONS 21' 10'-3" 1 SECTION 18" 5 SECTIONS 21' 10'-6" 6 SECTIONS 21" - 10'-9' 6 SECTIONS 18" 1 SECTION 21" 11' 5 SECTIONS 18" 2 SECTIONS 21" 11'-3" 4 SECTIONS 18" 3 SECTIONS 21- 1 V-6" 3 SECTIONS 18' 4 SECTIONS 21" 11'-9" 2 SECTIONS 18" 5 SECTIONS 21" 12' 1 SECTIONS 18" a SECTIONS 21" 12'-3' 7 SECTIONS 21" - 12'-8" 8 SECTIONS 18" 2 SECTIONS 21" 12-9" 5 SECTIONS 18" 3 SECTIONS 21" 13' 4 SECTIONS 18' 4 SECTIONS 21" id'-3" 3 SECNONS IS" 5 SECTIONS 21- 1 '-6' 2 SECTIONS 18" 6 SECTIONS 21' 13'-9' 1 SECTION 18" 7 SECTIONS 21" 14' 8 SECTIONS 21' - 14'-3' 6 SECTIONS 18" 3 SECTIONS 21" 14'-6" 5 SECTIONS 1W 4 SECTIONS 21' 14'-9" 4 SECTIONS IS" 5 SECTIONS 21" 15' 3 SECTIONS 18' 6 SECTIONS 21" iW-3" 2 SECTIONS 18" 7 SECTIONS 21" 15'-6" 1 SECTION 18" 8 SECTIONS 21' 15'-9" 8 SECTIONS 21" - 16' 6 SECTIONS 18" 4 SECTIONS 21" O O lJ m BRACKET BRACKL? STD. LIFT DOOR LOW HEADROOM DOOR OPTION 7-7/8" X 3-1/8" X .010" STEEL PLATE WITH (4) #14 X 3/4" SIDS CENTER STILE-1 A TOP FIXTURE 5-1/2" X 2-3/4" X 0.1" STEEL PLATE WITH ONE 5/16-18 MS W/ NUT OPTIONAL DOOR VIEWER FASTENED TO END STILE WITH X 3/4" SELF DRILLING SCREWS #14SHEET TO BE INSTALLED AT ANY CENTER STILE? �(6) SEE SHEET 3 FOR TOP BRACKET OPTIONS / SEE SCH.'A A MIA III !A Ilium, Fl=n- I I I I a STILE J\I LOCK BAR GUIDES 'L. INSTALLED ON END STILE WITH (4) #14 X 5/8" SMS 18T X .8W LOCK BAR ENGAGES IN TRACK ON EACH SIDE OF DOOR OPTIONAL OUTSIDE KEYED LOCK LOCK BAR LOCKING SHOWN ALT. TO LOCKS SHOWN ABOVE 8'-0" TO 9'-10" DOOR WIDTHS INSIDE ELEVATION LNO Hurricane M t1YO. RAISED PANEL EMBOSSED DOOR Max. Size Master® Model 0" High 1 Max. Size 18'-2" X 16'-0" High With Window Lite Option DESIGN GN PRRES-GRMAV rG + SF�t THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT �-.�! '`*����y��N& CENTER STILES SCHEDULE 'A' CENTER STILES CONFIGURATION DOOR WIDTHS OF CENTER STILES 8'-0" TO 9'-10" 2 10'-0" TO 11'-10" 2 12'-0" TO 13'•-10' 3 14'-0" TO 15,-10" 4 15'-11" TO 18'-2" 5 10'-0" TO Ill -10" 14'-0" TO 15'-10" DOOR WIDTHS DOOR WIDTHS ®®®®®® N= _ 12'-0" TO 13'-10" 15'-11" TO 16'-2" DOOR WIDTHS DOOR WIDTHS GENERAL NOTES 1, THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2010 EDITION INCLUDING HIGH VELOCITY HURRICANE ZONE. 2. ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 3. ALL BOLTS, NUTS AND WASHERS SHALL BE ZINC PLATED CARBON STEEL. 4. ANCHORING OR LOADING CONDITIONS OTHER THAN THOSE SHOWN IN THESE DETAILS ARE NpT PART OF THIS APPROVAL 5, A LOAD DURATION. INCf{FAaI., 4S USED IN DESIGN OF ANCHORS INTO WOOD ONLY. Engr.1 JAVAD A�T ID,��,1,�SW CIVIL FLA. PE 8 70592—DTS'T11S with the pm" 53p 1111 Code Aeo.p"No I . O`1 Ewpeellan 5 v 10 BY AtiMi PrCdntt 0,onW 0 O M 41 M ,pNI Q rn Z_ ~ N row yrno I 03� w Oz 0 � u7 rn� N s 4 0 ii drawing no. 02-21 t 24 GA. STEEL PANEL Ito{� o N a FLAPS BENT OVER PANEL I O Q, w L- 1 Q IL a 1% 0 0 1 /2" PUNC 0 � 0 4" D.C. O8 k 1 V p N Q 1 Qa<a i o_ O I Q�LL O 1 0 3/16" POP RNETS d , AT 4" O.C. (6) FOR 21" STILES (5) FOR 18" STILES M .024" STL PANEL LIj r7 END STILE OUTSIDE OF 000 ¢ IJi Z 03 w ° (n rn c3 1 €� si O 3 Oz o #14 X 3/4" SELF DRILLING SCREWS CAN BE USED o: ❑ = n OPTIONAL STOP MOULDING IN LIEU OF #14 X 5/8" SMS. mm 07 .� BY DOOR INSTALLER SOLID BRASS DOOR VIEWER Q a STEEL TRACK BRACKET FASTENED N ❑ '- _ TO WOOD JAMB WITH BY 'SCHLAGE SECURITY HARDWARE' 14 X 5/B" SINS 3/4" T 2" X 2-1/2" X PANE STEEL 5/16' % 1-5/8" LAG SCREW 6 PER HINGE END STILE, CONNECT TO PANELS WITH INSTALLED IN 9/16" DIA. HOLES IN CENTER STILE (FULLY THREADED) FLAPS AND (5) OR (6) 3/16" ALUM RIVETS POSITIONED AT EYE LEVEL HEX WASHER HEAD TYPE A 1/2" X 1-3/4" X .058" FORMED STEEL SEE DETAIL ABOVE ONE PER BRACKET GLUED TO PANEL AND SECURED TO ANCHORS: 3 END STILE WITH (4) 3/16' POP RNETS e SOUTHERN PINE EDGE 3/8" DIA, POWER -BOLT BY 'POWERS' 1 ."e°. 1-7/8" X 2-5/8" X 049" STEEL ¢ Y 0.55 S. DISTANCE I A) 2" MIN. EMBED INTO CONCRETE (3000 PSI MIN.) c • CENTER STILE, GLUED AND RIVETED I ° TO PANEL W/ (4) 3/16" RVETS 3/16" 2" MIN. EDGE DISTANCE pp55 0 1- MIN. POP RNETS • ° `. " I1/. 3 18 I[ q 14 X 5/8" S.M.S. : �,`i = i/e" DIA. HLC SLEEVE BY 'HILTi' u F d DIST. 4/ HINGE °" ' °" ' B) 1-1/4" MIN. EMBED INTO CONCRETE OR FILLED BLOCK R b b c 2-1/4" MIN. EDGE DISTANCE INTO CONCRETE 1-3/1 Or I 1 4" MIN. EDGE DISTANCE INTO FILLED BLOCK CONCRETE f't = 3000 PSI MIN. o O d r o C-90 GROUT FILLED BLOCK I'm 4 2000 PSI MIN. •2 1.9" X 2.19" X 3.3' X 090" ANCHOR TYPE A OR B u c w STEEL TRACK BRACKETS I 1 I 1 I /(l) ESHEET BRACKET3FOR BRACKET §P}141;riQ �— SEE SHEET 3 FOR SPACING ' ry "T1 , ..[n9r..JA A I AHMM PhODU(TF tEVISECI o� s I CIVIL Ba—$YT4WWIWCFImb 0 3 I FIA. PE @ 70592qffding 1/4-20 SS BOLT CA.N. 53Po 7-t/L X ,050" INTERIOR SIDE & NUT STEEL TRACK GALV. STEEL 7-1/2" X .N CENTER HINGE END ROVER HINGE ^ `1 Dy �- 14 GA. X 2-1/8' X i" (STANDARD) `O M•• 2 GA. X 3-5/16" X 1-1/2' (OPTIONAL)17/8'1.82' DIA. X .50" STEEL ROLLERS STD. o AoQutl ConYd drawing n0. FASTENED TO TRACK PLATES PUSHNUT ( ) r1 r�q W/ 1/4-20 X 5/8' TRUSS HD. INSTALLED ON ROLLER SHAFT 1.82" DIA X .SD" PLASTIC ROLLERS (OPTIONAL) OG_2 1 SLOTTED M.S. & LOCK NUT SECTION B-B 2.75" DIA. X .50" STEEL ROLLERS (OPTIONAL) WITH 4-1/4" STEM c O of F .055" X 2-1/4" X 3/4" X 2" GALV. STEEL U.BAR REINFORCING TRUSS 0 BOTTOM OF PANEL TRUSS FASTENED TO VERTICAL INTERMEDIATE STILES W/ TWO #14 X 5/8" S.M.S. AND TO END STILE r� W/ FOUR #14 X 3/4" SELF DRILLING S. O ?1 w rn U to 4 b 0 n WITH 1/8" X 1' S.M.S. ® 48' O.C. AND RUBBER WEATHERSTRIPPING 1ST SECTION (BOTTOM) INTERMEDIATE SECTION • •L �J v RIVETS 5/18 X 1-5/8" LAC SCREWS INTO WOOD OR 2-3/4" X 5-1/2" X 3" X .104" 5/16" SLEEVE ANCHORS CALV. STEEL WITH 1-1/4' EMBED INTO MASONRY ROLLER BRACKET 3 PER BRACKET FASTENED 6) N 14 X 5/8° S.M.S. - - 14 GA. GALV. STEEL ADJUSTABLE FASTENED TO BRACKET 2-1/2" X 4-1/4" X 13 GA. STEEL PLATES �SLIDE W/ 5/16-18 X 3/4" HEX HEAD - WELDED TO 1-1 /2" X 1-1/2" X 14 GA. ANGLE M. SCREWS & NUTS. FASTENED TO TRACK TOP BIACKEr WITH (4) 1/4-20 SS. BOLT & NUTS (STANDARD) TOP BRACKET (OPTIONAL) LOW HEADROOM DOOR HORIZONTAL REINFORCEMENT 1/2" X 1-3/4" X .058" FORMED STEEL -GLUED TO PANEL AND FASTENED TO VERTICAL STILES WITH (2) 3/16" POP RIVETS 2" X 5-1/2" X .104" GALV. STEEL FASTENED W/ (4) �P 14 X 5/8" S.M.S. HORIZONTAL REINFORCEMENT TOPP ROLLER BRACKET FOR LOW HEADROOM DOOR OPTION 1/2" X 1-3/4' X .058" FORMED STEEL TO PANEL AND FASTENED TO /GLUED VERTICAL STILES WITH (2) 3/16' POP RIVETS —5/16" MEETING RIB PLASTIC/STEEL ROLLERS 1 82" DIA. X .50" �W/ .44 DIA. X 4-1/4" STEM o OPTIONAL INSULATIONS: EPS-EXPANDED POLYSTYRENE DENSITY 1.05 PCF N.O.A. 907-1107.08 OR ISO-25 POLY-ISOCYANURATE DENSITY = 2.0 PCF N.O.A. #07-0301.10 OR DENSITY - 0.92 PCF N.D.A. #07-1018.07 14 GA. GALV. STEEL ROLLER HINGES FASTENED W/ (6) y 14 X 5/8" SMS MIN..024' ROLL FORMED STEEL PANEL DRAWING DUALITY G-40 MIN. YIELD STRENGTH - 39 KSI WITH PRIMER AND BAKED -ON POLYSTER PAINTED TOP COAT APPLIED TO BOTH SIDES OF STEEL 12 GA. GALV. STEEL BOTTOM BRACKET FASTENED W/ (4) B 14 X 5/8" SMS t BOTTOM SFAL .05B ALUM PLATE WITH 1/8" X 1" S.M.S. O 48" O.C. SECTION A -A AND RUBBER WEATHERSTRIPPING SEE SHEET 2 FOR LOCATION OF REINFORCING TRUSSES HORIZ. TRACK SUPPORT, CENTER SUPPORT REOD. ON DOORS EXPEEDING 8 FT. IN HEIGHT A—J 4 GA. GALV. STEEL TRACK 2 X 2 X 1/8" HORV. ANGLE SPOT WELDED TO HORIZ. TRACK WITH TWO WELDS AT 1-1/2' APART FIRST AT 3" O.C. REST AT 9" O.C. CONNECTED TO FLAG BRACKET ANGLE W/ 3/8-16 X 3/4" BOLT & NUT AND TO SPRING SHAFT GUIDE WITH (2) 1/4-20 X 5/8' BOLT & NUT VERTICAL TRACK 2-1/8X 1" X .080" SECTION A —A DOOR " SECTION HEIGHTS I BRACKET PLACEMENTS HEIGHT 1ST 2ND 13RD 14TH 5THM-1 B3 B4 B5 B6 B7 B8 6'-0" 18" 18" 18" 18" N/A 23" 34" 45" 56' 67" - 6'-6" 21" 18" N/A 23" 34°45' 56" 87°0' 21" 21" N/A 23" 34" 45" 56" 67"7'-8" 18" 18" ff"21" 18" 23" 34" 45" 58" 67" 78-1/4"21" 18" 21' 2- -­ U 11— — RUMCLKGU WAKIINV Al IKC CVIIVM FOR DOORS MORE THAN B FT. HIGH, USE ADDITIONAL TRACK BRACKETS AT 10" O.C. 1.9' X 2.19" X 3.3" X .090" STEEL TRACK BRACKETS 2-3/16" HIGH CONNECTED TO TRACK WITH (4) 1/4" BOLTS & NUTS. LOW HEADROOM DOUBLE TRACK z IL C O 0 � v O M 0a> 0"5 �q O aW3LLd� LL 3W E ign yAVAD' AHMM '' PROIDUCF REVISED o CfVIL , mcomplyftwith the FTolidt i FIA,'PE L10592 Code CA.N. 36. Ampt mNO 24 %0 « ` &pImlidn 6r 5 By_ r Q� io+t1, Mime{ ft"-C-Ad drawing no. N 02-21 sheet 3 of 5 g 1-1/2" MIN . IST.E DIST. O O H 1/4" DIA . SCREWS I WOOD BU I_ 0615FROO C ENDS SCREWS AT 6" FROM ENDS 2BY AND 15' O.C. MAX. I K. WOOD FRAME BUILDINGS STUD WALLS OR DOOR OPENING (NOT BY DAB DOORS) SHALL BE FRAMED SCUD BY NOT LESS THAN (3) 2X6 PRESSURE TREATED GRADE 2 SYP OR BETTER WOOD STUDS. STUD WALLS TO BE CONT. FROM FOOTING TO TIE BEAM ENGINEER OF RECORD TO VERIFY ADEQUACY OF THE SUPPORTING STRUCTURE. TRACK SHALL BE SECURED WITH CONT. STEEL ANGLE TO PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO GROUTED REINFORCED MASONRY BLOCK WALL OR CONIC. COLUMN WITH 1/4" ULTRACON BY 'ELCO' WITH SPACING OF 18" O.C. INTO BLOCK WALL, WITH 2-1/4" MIN. EMBED 13" O.C. MO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 2-1/2' MIN. EDGE DISTANCE 1/4' TAPPER BY 'POWERS' WITH SPACING OF 11" O.C. INTO BLOCK WALL, WITH 1-1//2' MIN. EMBED 13" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 3" MIN. EDGE DISTANCE CONFLE% BY 'ELCO' OR 3/8" LDT BY 'IN/' WITH SPACING OF 23" O.C. INTO 3000 PSI CONCRETE. WITH 2-1/2" MIN. EMBED 3" MIN. EDGE DISTANCE 3/8" HLC SLEEVE BY 'HILTI' WITH SPACING OF 13` O.C. INTO BLOCK WALL, WITH 1-1/4' MIN. EMBED, 4" MIN. EDGE DIST. 15" O.C. INTO 3000 PSI CONCRETE, WITH 1-1/4" MIN. EMBED AND 2-1/2" MIN, EDGE DISTANCE THE BLOCK WALL CELLS SHALL BE GROUT FILLED AND REINFORCED WITH FOUR A 5 BARS EXTENDING INTO FOOTING AND INTO TIE BEAMS ALL BARS S ALL BE CONTINUOUS FROM TIE BEAMS TO FOOTING. PREPARATION OF JAMBS BY OTHERS 5/16" X 1-5/8- LAG SCREWS AT i STEEL STRUCTURE BY OTHERS MUST SUPPORT THE LOADS IMPOSED BY DOOR SYSTEM �v it Z n 0 m N Q M N Q; O LL 08 0:2 0 oaaoo N J Q Wei �L F fW'J O Lj o M M N >Q z to Z o0W g (n rn O 1 CONCRETE V. a 3000 PSI MIN. 0 ' C-90 GROUT FILLED BLOCK I'm - 2000 PSI MIN. 5/16" DIA. BOLTS � O Z (9 WRH WASHER & NUT o 0 _ AT 12" O.C. MAX. EDGE DIST. ANCHOR SPACING ANCHORS I STRUCTURE EMBED I SPACING EDGE DIST. 3 8 HLC SLEEVE BY HILT CONIC. 1-1 4 B" 2" 3 8" HLO SLEEVE BY HILTI' FILLED BLOCK 1-1 4" e` 3 8" DYNABOLT BY'ITW' CONIC. 1-1 2 8" 2-1"2 3 B" DYNABOLT BY 'ITW FlLLED BLOCK 1-1 2 4 3 8 POWER -BOLT 8Y POWERS CONIC. 2" 3 B SLEEVE -ALL BY SIMPSONS CONIC. 1-1 2 8" 3` 1-1/4" X 2-1/2" X 14 CA CON . STEEL ANGLE I1-1/2" 12 GA GALV. STEEL FLAT BRACKETS t3" LONG AT 12" O.C. IN DOOR CPNG. AT 18" O.C. ABOVE DOOR OPNG. CONNECTED TO CONT. ANGLE W/ (3) SPOT WELDS AT EACH SIDE�'FIASTENED 2_1/B" X 1' X 14 GA. ALV. STEEL TRACK TRAC/KK PLATES SL(())//TO 077ED 1fA.S. &XLbCK NUTS HD. ALTERNATE TRACK INSTALLATION CIVIL FLA. PE d. 76,462 C.+N; 5'S8 O �1 0 PROD=REVISED Y :Tocwoyingwith ftFk*Ma $ t BuildiM.Co/e AcaP„n«ra 20IO S k Espindan t— M�avi Iic�dtai Caovel drawing no. 02-21 J O K O 'IEG DOOR PANEL 24 GA. (.024) STEEL MIN. 6" DIA. WASHER �8 X 3/4" SMS �0 3/8' FROM ENDS AND 7" O.C. MAX. _(4) #8 X 3/4' SMS ® 1-3/8' FROM ENDS AND B-1/2" O.C. MAX. 175 X .052 DEEP GROOVE 1/4" POLYCAR80NATE LEXAN BY SABIC INNOVATIVE PLASTICS NOA #00-0305.02. 175 X .062 DEEP ;ROOVE (4) p8 X 3/4" SMS /-® 1-3/8" FROM ENDS AND 6-1/2" O.C. MAX. Q8 X 3/4" SMS 0 3/8' FROM ENDS AND 7" O.C. MAX. DIA. WASHER DOOR PANEL . 24 GA. (.024) STEEL MIN. #8 X 3/4' SMS ® 3/8' FROM ENDS AND 4-1/2' O.C. MAX.] DOOR PANEL 24 GA (.024) STEEL MIN. b-"i-.25D * PLASTIC COMPLIES WITH .500 �uI I o SECTION 2612 OF FBC 2007 w SEE EVIDENCE PAGE o a0 0� $� t= W OPTIONAL WINDOW LITES IN ANY LOCATION 1.765 L725 a' o c 0 0 1.144 a 0o 0176 � n II I Ci o � * EXTERIOR FRAME * INTERIOR FRAME RIGID PVC ONE PIECE INJECTION RIGID PVC ONE PIECE INJECTION a 3 LL a IL i Q LLI O I' z 0 0 O o t7 M N Q .J Z I=- UI W W O (n m O I O .92 15/16' MIN. INSIDE ELEVATION RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS /-GROOVE'082 DEEP - - - - - - - EngA•JAVAD AIIMAD ..:_..-..-..-.. _:. FLA. PE.R 70592 O.A.N. '353B EXTERIOR TH N 0 PR0MWf YRVtRD do Plyi:q with I tFbd& euI. N' �wl5 $ I s n s drawing no. 02-21 N M t1+."c tm sheet 5 of 5 N, . These Tables Are For GARAGE DOORS IN One and Two Family Dwellings Garage Doors Installed In Buildings with a Mean Roof Height of 30' or Less Located in Exposures B,C or D Table R301.2(4) COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE-[PSF] ❑160 EXPOSURE B 9' x 7' Door = + 26.7 - 30.2 ❑160 EXPOSURE B 16' x 7' Door = + 25.6 - 28.5 7160 EXPOSURE C 9' x 7' Door = + 32.4 - 36.6 (1 storyand max 15' 160 EXPO�SUREC�16'Xo7=,Doors 31�834, mean roof height) ❑160 EXPOSURE C 9' x 7' Door = + 37.4 - 42.3 ( 2 story and max 30' ❑160 EXPOSURE C 16' X 7' Door = + 35.9 - 39.9 mean roof height) 0160 EXPOSURE D 9' x 7' Door = + 39.3 -44.4 (1 storyand max 15' ❑160 EXPOSURE D 16' x 7' Door = + 37.7 -41.2 mean roof height) ❑160 EXPOSURE D 9' x 7' Door = + 44.3 - 50.2 ❑160 EXPOSURE D 16' x 7' Door = + 42.5 - 47.4 7150 EXPOSURE B 9' x 7' Door = + 22.8 - 25.8 7150 EXPOSURE B 16' x 7' Door = + 21.8 - 24.3 ❑150 EXPOSURE C 9' x 7' Door = + 27.6 -31.3 7150 EXPOSURE C 16' x 7' Door = + 26.4 - 29.5 ❑150 EXPOSURE C 9' x 7' Door = + 32.0 - 36.2 7150 EXPOSURE C 16' x 7' Door = + 30.6 - 34.1 7150 EXPOSURE D 9' x 7' Door = + 33.6 - 38.0 ❑150 EXPOSURE D 16' x 7' Door = + 32.1 - 35.8 ❑150 EXPOSURE D 9' x 7' Door = + 37.9 - 42.9 ❑150 EXPOSURE D 16' x 7' Door = + 36.2 - 40.4 ( 2 story and max 30' mean roof height) (1 story and max 15' mean roof height ( 2 story and max 30' mean roof height) (1 story and max 15' mean roof height) (2 story and max 30' mean roof height) Notes: ■ Secure existing bucks per the Product Approval or Design Professional Instructions prior to installing the door. Have product approvals available at the time of inspection. ■ Glazing in Garage doors must comply with R301.2.1.2 (Glazing must be impact resistant or shuttered)