HomeMy WebLinkAboutFL ENERGY EFFICIENCY CODEFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: DON MIRANDA
Builder Name:
SCANNED
Street: 10786 GREY HERON CT
Permit Office: PORT ST LUCIE
City, State, Zip: PORT ST LUCIE , FL, 34986
Permit Number:
BY
'! Owner:
Jurisdiction: 612000
St. Lucie Count,
Design Location: FL, ST LUCIE CO_INTL
`1. New construction or existing Addition
9. Wall Types (554.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Frame -Wood, Exterior
R=19.0 554.00 ftz
b. N/A
R= ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms(Bedrms In Addition) 0(0)
d. N/A
R= fP
10. Ceiling Types (369.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Unvented)
R=30.0 369.00 ftz
6. Conditioned floor area above grade (ftz) 369
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
11. Ducts
R ftz
7. Windows(192.0 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Attic
6 73.8
a. U-Factor: Dbl, U=0.65 192.00 ftz
SHGC: SHGC=0.22
b. U-Factor: N/A ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
48.0 SEER:16.00
c. U-Factor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. _U-Factor: N/A ftz
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.220
14. Hot water systems - None required
8. Floor Types (369.0 sqft.) Insulation Area
a.
Cap: N/A
EF: 0.000
a. Slab -On -Grade Edge Insulation R=0.0 369.00 ftz
b. Conservation features
b. WA R= ftz
c. WA R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.520 Total Proposed Modified Loads: 23.99
PASS
Total Baseline Loads: 24.54
U hereby certify that the plans ands ecifications cove d by
Review of the plans and
vthiE ST,;
"this calculation are in com ce with the Florida nerg
specifications covered by this
Code.
calculation indicates compliance
•
with the Florida Energy Code.
am :. _��,, •r; y .• . ,� �O
PREPARED B
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
a ;
a
* e
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
CDD
with the Florida Energy Code.
WE•i��
OWNER7W-�-
BUILDING OFFICIAL:
DATE:DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 amend an -en'. lope y1eakage
test report in accordance with R402.4.1.2.
LILi
3/21/2016 9:25 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2014
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/E)asting:
Comment:
DON MIRANDA
User
1
PORT ST LUCIE
612000
Single-family
Addition
Bedrooms: 0
Conditioned Area: 2490
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
10786 GREY HERON C
St. Lucie
PORT ST LUCIE ,
FL, 34986
CLIMATE
Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL ST LUCIE_CO_INTL 2 39 90
70
75 722
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
369 4428
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
369 4428 Yes 1
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 46.2 ft 0
369 ft2
----
0 0 1
ROOF
/
v #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Metal 400 ft2 0 ft2 Light
0.96
No 0.9
No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300
369 ftz
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
Under Attic (Vented)
Main 30 369 ft2
0
Wood
3/21/2016 9:25 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
WALLS
9 Omt
Adjacent
To Wall Imp1
Space Cavity Width Height Sheathing Framing Solar
Below
N
2 W
Exterior Frame - Wood
Exterior Frame - Wood
Main 19 34 2 12 410.0 ft2 0 0.75
Main 19 12 12 144.0 ft2 0 0.75
0
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
#
Wall
Omt ID Frame Panes
Overhang
NFRC U-Factor SHGC Area Depth Separation Int Shade
Screening
1
N 1 Metal Low-E Double Yes 0.65 0.22 192.0 ft2 2 ft 0 in 1 ft 0 in None
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000381 369 20.26 38.1 .2859 5
HEATING SYSTEM
#
System Type
Subtype Efficiency Capacity Block
Ducts
1
Electric Strip Heat
None COPI 34 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit
None SEER: 16 48 kBtulhr 1440 cfm 0.75 1
sys#1
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
ft2
DUCTS
/
v #
— Supply —
Location R-Value Area
— Return — Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
Attic 6 73.8 ft2
Main 18.45 ft Default Leakage Attic (Default) (Default)
1 1
3/21/2016 9:25 AM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
TEMPERATURES
Programable Thermostat: None
Ceiling Fans:
CoolingJan
HeatinJan
Feb
Feb
Mar
Mar
H
r
Er
f
May
May
X] Jun
4 ]Jun
X Jul
Jul
I
AugX]
AuI
rl
j
Se
Sep
] Oct
[ ]Oct
Nov
Nov
Dec
Dec
Ventin Jan
Feb
Mar
[X] r
[
jjj May
l ] Jun
Jul
Aug
[ ]]
Se
[X] Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating(WD)
AM
68
68
68
68
68
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating(WEH)
AM
68
68
68
68
68
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
3/21/2016 9:25 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
ENERGY
PERFORMANCE LEVEL
(EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
10786 GREY HERON CT, PORT ST LUCIE, FL, 34986
ti
1. New construction or existing
Addition 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Frame - Wood, Exterior
R=19.0
554.00 ft2
b. N/A
R=
ft2
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
0(0) d. N/A
R=
ft2
5. Is this a worst case?
10. Ceiling Types
No
Insulation
Area
a. Under Attic (Unvented)
R=30.0
369.00 ft2
6. Conditioned floor area (ft2)
2490 b. N/A
R=
ft2
7. Windows— Description
Area c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.65
192.00 ft2 11. Ducts
a. Sup: Attic, Ret: Main, AH: Attic
R ft2
6 73.8
SHGC: SHGC=0.22
b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2 a. Central Unit
48.0 SEER:16.00
SHGC:
d. U-Factor: N/A
ft2 13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
34.0
COP:1.00
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.220
8. Floor Types • Insulation Area 14. Hot water systems - None required
Cap: N/A
a. Slab -On -Grade Edge Insulation R=0.0 369.00 ft2 a•
EF:
b. N/A R=
ft2
c. N/A R=
ft2 b. Conservation features
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code comA liant features.
Builder Signature: - Date:
Address of New Hom City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, icy, E .-AU LT
3/21l2016 9:29 AM EnergyGauge®USA - FlaRes2014 -Section R405.4.1 Compliant Software tgr
tR 1
2