Loading...
HomeMy WebLinkAboutFL ENERGY EFFICIENCY CODEFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: DON MIRANDA Builder Name: SCANNED Street: 10786 GREY HERON CT Permit Office: PORT ST LUCIE City, State, Zip: PORT ST LUCIE , FL, 34986 Permit Number: BY '! Owner: Jurisdiction: 612000 St. Lucie Count, Design Location: FL, ST LUCIE CO_INTL `1. New construction or existing Addition 9. Wall Types (554.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame -Wood, Exterior R=19.0 554.00 ftz b. N/A R= ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms(Bedrms In Addition) 0(0) d. N/A R= fP 10. Ceiling Types (369.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Unvented) R=30.0 369.00 ftz 6. Conditioned floor area above grade (ftz) 369 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 11. Ducts R ftz 7. Windows(192.0 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Attic 6 73.8 a. U-Factor: Dbl, U=0.65 192.00 ftz SHGC: SHGC=0.22 b. U-Factor: N/A ftz 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 48.0 SEER:16.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. _U-Factor: N/A ftz a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.220 14. Hot water systems - None required 8. Floor Types (369.0 sqft.) Insulation Area a. Cap: N/A EF: 0.000 a. Slab -On -Grade Edge Insulation R=0.0 369.00 ftz b. Conservation features b. WA R= ftz c. WA R= ftz 15. Credits Pstat Glass/Floor Area: 0.520 Total Proposed Modified Loads: 23.99 PASS Total Baseline Loads: 24.54 U hereby certify that the plans ands ecifications cove d by Review of the plans and vthiE ST,; "this calculation are in com ce with the Florida nerg specifications covered by this Code. calculation indicates compliance • with the Florida Energy Code. am :. _��,, •r; y .• . ,� �O PREPARED B DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 a ; a * e I hereby certify that this building, as designed, is in compliance Florida Statutes. CDD with the Florida Energy Code. WE•i�� OWNER7W-�- BUILDING OFFICIAL: DATE:DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 amend an -en'. lope y1eakage test report in accordance with R402.4.1.2. LILi 3/21/2016 9:25 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/E)asting: Comment: DON MIRANDA User 1 PORT ST LUCIE 612000 Single-family Addition Bedrooms: 0 Conditioned Area: 2490 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address 10786 GREY HERON C St. Lucie PORT ST LUCIE , FL, 34986 CLIMATE Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL ST LUCIE_CO_INTL 2 39 90 70 75 722 58 Medium BLOCKS Number Name Area Volume 1 Blockl 369 4428 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 369 4428 Yes 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 46.2 ft 0 369 ft2 ---- 0 0 1 ROOF / v # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 400 ft2 0 ft2 Light 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 369 ftz N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 369 ft2 0 Wood 3/21/2016 9:25 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS 9 Omt Adjacent To Wall Imp1 Space Cavity Width Height Sheathing Framing Solar Below N 2 W Exterior Frame - Wood Exterior Frame - Wood Main 19 34 2 12 410.0 ft2 0 0.75 Main 19 12 12 144.0 ft2 0 0.75 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. # Wall Omt ID Frame Panes Overhang NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Double Yes 0.65 0.22 192.0 ft2 2 ft 0 in 1 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000381 369 20.26 38.1 .2859 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPI 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 16 48 kBtulhr 1440 cfm 0.75 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF ft2 DUCTS / v # — Supply — Location R-Value Area — Return — Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 73.8 ft2 Main 18.45 ft Default Leakage Attic (Default) (Default) 1 1 3/21/2016 9:25 AM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 TEMPERATURES Programable Thermostat: None Ceiling Fans: CoolingJan HeatinJan Feb Feb Mar Mar H r Er f May May X] Jun 4 ]Jun X Jul Jul I AugX] AuI rl j Se Sep ] Oct [ ]Oct Nov Nov Dec Dec Ventin Jan Feb Mar [X] r [ jjj May l ] Jun Jul Aug [ ]] Se [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/21/2016 9:25 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 10786 GREY HERON CT, PORT ST LUCIE, FL, 34986 ti 1. New construction or existing Addition 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=19.0 554.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0(0) d. N/A R= ft2 5. Is this a worst case? 10. Ceiling Types No Insulation Area a. Under Attic (Unvented) R=30.0 369.00 ft2 6. Conditioned floor area (ft2) 2490 b. N/A R= ft2 7. Windows— Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.65 192.00 ft2 11. Ducts a. Sup: Attic, Ret: Main, AH: Attic R ft2 6 73.8 SHGC: SHGC=0.22 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 48.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.220 8. Floor Types • Insulation Area 14. Hot water systems - None required Cap: N/A a. Slab -On -Grade Edge Insulation R=0.0 369.00 ft2 a• EF: b. N/A R= ft2 c. N/A R= ft2 b. Conservation features 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code comA liant features. Builder Signature: - Date: Address of New Hom City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, icy, E .-AU LT 3/21l2016 9:29 AM EnergyGauge®USA - FlaRes2014 -Section R405.4.1 Compliant Software tgr tR 1 2