Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
DATE: FEES DUR, RECEIPT Permit #: Planning & Development Services Department Building & Code Regulation Division SC 2300 Virginia Avenue 'q/1/ Ft. Pierce, FL 34982-5652 S/ e �FQ Tel. 772462-1553 UC/ APPLICATION FOR ROOF PERMITSEE REVERSE SIDE FOR INSTRUCTIONS e cocnty 1. Location/Site Address: 5 2 I�iC' _ es B I VCl 2. Parcel ID Number: 45 p 1- ` - 1 p 4 t( - pop ,- 8 Office Use Only Section I Township Range Map Page Zoning Land Use I I 'ti is 3. Description of Project or Work Activity: Re - Rcaof Z Tear ©- 4. Total Roof Area (square feet): 500 5. Roof Pitch: 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Tar & Gravel [ ] Modified Bitumen [ ] Wood Shake / Shingle " Other M e-ta-I [✓] Product Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: Address: City: l o lit' Est• Lue6 C. State: - L. Zip: Phone: (11a) 93 U - 6.5Oa 9. Value of Construction: $ 3, A00 FL Reg/Cert #: (I C-C JAB ('75 '7 County Cert #: Business Name: Du r holm .BLOS-;?ink Cell Phone: (5fo 0 3 15 - ( $_3 5 "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compli ce all applica ws re lating construction and zoning. TOWN �. ��✓�ti� ,9� PRINT QUALIFIERS/OWNERS NAME // Sr URE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF L _'t ( -, � " ACKNOWLEDGED BEFORE ME THIS :DAY OF 20_LLL BY W IS ONALLY OWN. -TO ME OR HAS PRODUCED . AS IDENTIF A➢i___ 1H HOLLY CONRAD �xn j r_ MYGOti�,USSIQN.� IGNATURE BY TYPI ,OR INT NAME OF NOTARY (seal) = (i0?9I5 ..... 8.EXPAES: June 25: 2014 ZyPtibBcUrtdervm7cys COMMISSION NUMBER � Ei�m: ' . � � "`.." ." :.`- " • .. NOTICE TO OWNER: FAILURE.TO'_RECORD.A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY., IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING .YOUR NOTICE OF COMMENCEMENT. Revised 4/262010 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # I, JTnh n Du r h a-rn licensed as a(n)Contractor*/Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about Q I i(n3 f 52-014 , I did personally inspect the roof deck nailing (bate) work at: NP i'{' IES 13 i V4 (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) Signature and Seal STATE OF FLORIDA COUNTY OF :t± L-kA C(0'-1 License # Swo n 1to and subscribed before me this da of J 20j1-, byyly\ )'YLr\,\.ccyv,,, . Who is personally known to m or ho has produced as identification. HOLLYOMRAD ' NotaryPublic State of Florida tir; MYCOMMISSIOne25,2 145 � EXPIRES: June 25, 2014 Signature of Notary: ; ¢^ Bonded ThruNotaryPublkUnderwdters Commission Number: e a F 5d (Seal) En 01/19/2011 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3913435 OR BO,'593 PAGE 2493, Recorded 01/08/2014 '10:29 AM Permit No. _ State of Florida County of St. Lude NOTICE OF COMMENCEMENT Tax Folio No, 450a-501-In44-AM-R' The undersigned hereby gives notice that Improvement will be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the following Information is provided In this Notice of Commencement. Legal of Property: (and street address If avallahle): �1Cftl ST lanri'T'n�,A [tof4an.snc-Finn Common Elerren s General description of improvement:_- ISM - KOOS Owner Irrf Le" or tInfQ►matlon if the Lessee contracted for the Improvement: Name C°ah Bi6C_K-;Tn- - Address _ R.riR N—fflPS -hl_X_IM Interest in property: __n LOT) e f Name and address of fee simple titleholder (If different from Owner listed above): CardractorsName: fl?�0rn .B1.0+1nerStr T,0 ContrectorAddress: 158gi 6a nd E1402 OJ Ld n @ Phone Number 3-1a r O oli Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ Name and address: Phone number: Lender Name: Phone Number: Lenders address: Persons within the State of Florida designated by owner upon whom notices or other documents may be served as provided by Section 713.1311) (a)7., Florida Statutes: Name: Phone Number: Address: In addition to himself or herself, Owner designates of to receive a copy of the Uenors Notice as provided In Section 713,1 1) (b), Florida Statutes. Phone number of person or entity designated by owner: Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE J013 SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that I have readthe foregoing notice of commencement and that the facts stated therein are true to the best of my knowled and e1le. (Signature of Owner or Lessee', 6r. OVy[Ie?s'of Lessee's Aho ed' cO/Dire r/Partner/Manager (Signatory's Title/Office)=YOOFQi1D . - i, UYQ73(J�pN/�gtie(e P014 The foregoing Instrument was atknowledgedktaforemethls.�_aday , 24 arrridObcir q � By 1Ph -6tat5,nra- for rson Type of authority (e.g. officer, trustee) Party on behalf of whom Instrument was executed Personally known or produced Identification_ 4gWnatureof ate offlo (print, Type, or5tamp ssloned NaRte of Notary Public) Type of Identification produced STATE or FLOR,94 ST. Luca: COUPTY THIS IS TpGT►�5rMAT T�IS ►�UCC{l RCCT A �oPy OF Tf I A AL. 1 �' Py E. Smg... �LE • li J-W Engineering, Inc. C.O.A.#9937 Civil and Structural Engineering January 10, 2014 St. Lucie County — Building Division 2300 Virginia Avenue Fort Pierce, FL 34982 RE: Mobile Home Roof Replacement, 858 Nettles Blvd., Port St. Lucie, FL TO WHOM IT MAY CONCERN: At the request of the residence owner, I have reviewed the roof framing system at the referenced property. This assessment was made because of the owner's intent to replace the existing asphalt single roof covering with light -gauge steel. EXISTING & PROPOSED CONDITIONS: The roof assembly consists of 2x4 framed trusses on 24" centers with plywood do^ The existing roof covering is asphalt shingles over a "felt" underlayment. .90 The intent is to remove the existing covering down to the plywood decking and re ce it 'th a 1" nail strip standing seam steel panel roof covering manufactured by Sunlast Metals, Inc. c pproval #FL 10490-2 R2] over a self -adhering underlayment manufactured by Tarco Roofmg r duct Approval #FL 10450-R4]. The weight differential between the existing roof covering and the proposed roof coverin will an increase of approximately one (1) pound per square foot of roof area. CONCLUSION: 0� To the best of my professional opinion, knowledge and belief, the roof structural system is capabl safely supporting the increased loading conditions of the proposed steel roof covering. CLOSURE: Please feel free to contact me at (561) 630-3550 for further information as the need arises. Respectfully,' uV Ja YW. Wesson, P.E. Florida License No. 46487 ST LU�IE CQ[J;��UTI.DTNG D11%ION REVIEWED FOR C REVIEWED BY DATE PLANS AITD PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE. �4 20 Balfour Road West, Palm Beach Gardens, FL 33418•Phone: (561) 630-3550•Fax: (561) 630-0403 CBUCK Enalneerina SpPCicsift l Structural Enc 1nLapr1n(3 CBUCK, Inc. Certificate of Authorization #8064 Evaluation Report "I" Nail Strip" Metal Roof Assembly Manufacturer: Sunlast Metal, Inc. 2120 SW Poma Drive Palm City, FL 34990 (772) 223-4055 for Florida Product Approval . # FL 10490.2 R2 Florida Building Code 2010 Per Rule 9N-3 Method: 1- D Category: Roofing Sub - Category: Metal Roofing Product: "1" Nail Strip" Roof Panel Material: Steel Panel Thickness: 24 gauge Panel Width: 16" Support: Wood Deck Prepared by: James L. Buckner, P.E.. S.E.C.B. Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Diana Galloway Report No. 11-190-INS-S4W-ER Date: 2/6/ 12 Contents: Evaluation Report Pages 1— 7 CBUCK, Inc. 1399 N. Killian Drive, Suite 4, West Palm Beach, Florida 33403 Phone: (561)491-9927 Fax: (561)491-9928 Website: www.cbuckinc.net Florida P.E. # 31242 4)*) /-Z— CB FL#: FL10490.2-R2 Date: 2 / 6 / 12 CBUCKEnalneerinc3 Report No.: 21-1 1NS-S4W-ER SCleclaltu Structural enc,11neerina CBUCK, Inc. Certificate of Authorization #8064 Manufacturer: Product Name: Product Category: Sunlast Metal, Inc. "1" Nail Strip" Roofing Product Sub -Category Metal Roofing Compliance Method: State Product Approval Rule 9N-3.005 (1) (d) Product/System "1" Nail Strip" Description: 24 gauge Steel roof panel mechanically attached to Plywood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Fasteners 3. Adhesive 4. Underlayment 5. Insulation (Optional) Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32 (min.) or greater plywood, • or Wood plank (min. specific gravity of 0.42) Slope: Minimum slope shall be in accordance with manufacturer's recommendations, FBC Section 1507.4.2 and applicable code sections. Performance: Wind Uplift Resistance: • Design Uplift Pressure: METHOD 1: - 91.25 PSF (Refer to "Table A" attachment details herein) METHOD 2:-106.25 PSF CBUCK Enalneerina FL #: FL 10490.2-112 Date: 2 / 6 / 12 Report No.: 11-190-1NS-S4W-ER Page 3 of 7 Simeclaltu Structural Enaneerina CBUCK, Inc. Certificate of Authorization #8064 Performance Standards: The product described herein has demonstrated compliance with: • UL580-06 —Test for Uplift Resistance of Roof Assemblies • UL 1897-04 —Uplift test for roof covering systems • TAS 125-03 — Standard Requirements for Metal Roofing Systems Standards Equivalency: The UL 580-94 & UL 1897-98 standard version used to test the evaluated product assembly is equivalent with the prescribed standards in UL 580-06 & UL 1897-04 adopted by the Florida Building Code 2010. Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 2010, Section 1504.3.2. Evaluation Report This product evaluation is limited to compliance with the structural requirements Scope: of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 9N-3.001. Limitations and • Scope of "Limitations and Conditions of Use" for this evaluation:. Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 9N-3.005. Per Rule 9N-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval'. • Oxon for application outside "Limitations and Conditions of Use" Rule 9N-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 9N-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 9N-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA 1824). CBUCK Enalneerina FL #: FL 10490.2-112 Date: 2 / 6 / 12 Report No.: 11-190-INS-S4W-ER Page 4 of 7 Sc3eclaltu Structural Enalneerina CBUCK, Inc. Certificate of Authorization #8064 Components/Materials (by Manufacturer): Components/Materials (by Others): Roof Panel: "1" Nail Strip" Material: Steel Thickness: 24 gauge (min.) Panel Width: 16" (max.) Coverage Rib Height: 1" Yield Strength: 40 ksi min. Corrosion Resistance: In compliance with FBC Section 1507.4.3: • ASTM A792 coated, or • ASTM A653 G90 galvanized steel Fastener: Type: Pancake -Head Wood Screw Size : #10 x 1" Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.4 Seam Adhesive/Sealant: Product Name: Bostik Chem-Chaulk 915 Type: One component, polyurethane adhesive Application Size: 3/8" bead Application Location: along male flange the full length of panel (Refer to Table "A" and drawing Page 7) Underlayment: Per roofing manufacturer's guidelines in compliance with FBC Section 1507.4.5 Insulation (Optional): Type: Thickness: Properties: Density: Or Compressive Strength: Rigid Insulation Board 3" (max.) 2.25 pcf (Ibs/ft3) min. 20 psi min. Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". CBUCK Enaineerina FL #: FL 10490.2-112 Date: 2/6/12 Report No.: 11-190-1NS-S4W-ER Page 5 of 7 ISimeclaltu Structural Enalneerinca CBUCK, Inc. Certificate of Authorization #8064 Installation: Installation Method: (Refer to drawings on Pages 6-7 of this report.) ■ Fastener spacing: Refer to Table "A" Below (along the length of the panel) ■ Rib Interlock: Snaplock (Panel ribs shall be fully engaged to form an integral snap -lock) ■ Minimum fastener penetration thru bottom of support, 3/16". ■ For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A" METHOD 1: METHOD 2: Design Pressure: - 91.25 PSF -106.25 PSF Fastener Spacing: 12" 6" Adhesive: 3/8" Bead Refer to Dwg PR 6 3/8" Bead Refer to Dwg Pg 6 Install the "1" Nail Strip" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 2010. The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. TAS 125-03 Uplift Test By Hurricane Test Laboratory, LLC (FBC Organization #TST ID: 1527) Report #: 0412-0306-06; Test Date: 11 / 14 / 06 Report #: 0412-1203-07; Test Date: 12 / 17 / 07 2. Qua lityAssurance By Keystone Certifications, Inc. (QUA ID: 1824) Sunlast Metal & Solar, Inc. Licensee # 385 3. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) r-� CBUCK Enalneerina FL #: FL 10490.2-R2 Date: 2 / 6 / 12 Report No.: 11-190-1NS-S4W-ER Page 6 of 7 SpE=Cidltu Structural ErI oneerlm CBUCK, Inc. Certificate of Authorization #8064 Installation Method Sunlast Metal, Inc. "1" Nail Strip" (24 Gauge) Roof Panel Attached to Wood Deck Profile Drawings 16" Striations "1" Nail Strip" Panel Typical Panel Profile View 16" o.c. Wood Deck Integral Snap Lock Seam Adhesive Apply 3/9' bead Bostik Sealant entire length of panel along male flange #10 x 1" Pancake -Head Screw Assembly Profile View Typical Fastening Pattern Across Row 1.0" i— CBUCK f � E=nc 31nL =rina FL #: FL 10490.2-112 Date: 2 / 6 / 12 Report No.: 11-190-1NS-S4W-ER Page 7 of 7 SpPclaltu Structural Enc3lnPprinc3 CBUCK, Inc. Certificate of Authorization #8064 Installation Method Sunlast Metal, Inc. "1" Nail Strip" (24 Gauge) Roof Panel Attached to Wood Deck Fastener: (Refer to Table W) Typical Assembly Isometric View TABLE "A" METHOD 1: METHOD 2: Design Pressure: - 91.25 PSF -106.25 PSF Fastener Spacing: 12" 6" Adhesive: 3/8" Bead Refer to Dwg Pg 6 1 3/8" Bead Refer to Dwg Pg 6 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 TUNIT #13 QOD IA SIN I ERD 353 CHRISTIA OXFORD, CT 6478 I� 1 V PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Tarco Roofing Evaluation Report 10880.07.08-114 One Information Way, Suite 225 FL10450-114 Little Rock, AR 72202 Date of Issuance: 07/11/2008 Revision 4: 02/25/2013 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Tarco Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/25/2013 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest In any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the product. �I TRINITY I ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Tarco, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property t n and Year 1507.2.3, 1507.3.3, 1507.5.3, Physical Properties ASTM D226 2006 1507.7.3, 1507.8.3, 1507.9.3 1507.2.4, 1507.2.9.2, 1507.3.3, Physical Properties ASTM D1970 2001 1507.5.3 1507.2.9.2 Physical Properties ASTM D3909 1997 1507.2.3, 1507.5.3, 1507.7.3, Physical Properties ASTM D4869 2005 1507.8.3, 1507.9.3 1507.11.2 Physical Properties ASTM D6164 2005 1507.3.3 Physical Properties ASTM D6380 2003 1504.3.1 Wind Uplift FM 4474 2004 1507.3.3 Installation Practice FRSA/TRI 07320 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity Ex9min to ion Reference Date ERD (TST6049) ASTM D6164 T6470.08.07-R1 08/30/2007 ERD (TST6049) FM 4474 T6460.06.07-111 10/09/2007 ERD (TST6049) ASTM D1970 T30160.08.09 08/14/2009 ERD (TST6049) TAS 103 T33190.08.10 08/06/2010 ERD (TST6049) ASTM D1970 T32530.08.10 08/17/2010 ERD (TST6049) FM 4474 T37610.07.11 06/29/2011 ERD (TST6049) ASTM D3909 T40780.04.12 04/06/2012 ERD (TST6049) ASTM D6380 T40790.04.12 04/06/2012 ERD (TST6049) TAS 103 T35410.04.12 04/18/2012 PRI(TST5878) ASTM D1970 BRY-018-02-01 08/11/2003 PRI(TST5878) ASTM D1970 BRY-017-02-01 08/11/2003 PRI(TST5878) ASTM D226 TOT-014-02-02 05/18/2004 PRI(TST5878) ASTM D4869 TOT-013-02-01 05/20/2004 PRI(TST5878) ASTM D226 TOT-015-02-02 05/24/2004 PRI(TST5878) ASTM D6380 TOT-029-02-01 07/05/2005 PRI(TST5878) ASTM D4869 TOT-09-02-01 09/14/2004 PRI(TST5878) ASTM D226 TOT-041-02-01 05/24/2006 Miami -Dade (CER1592) FBC HVHZ Certification 08-0229.04 10/02/2008 UL, LLC. (QUA9625) Quality Assurance Service Confirmation Exp. 12/08/2014 4. PRODUCT DESCRIPTION: 4.1 Self -Adhering Underlavments: 4.1.1 LeakBarrierO Fast9OO Self -adhering Tile Underlayment is an asphalt -saturated organic felt coated on both sides with asphalt and surfaced on the top side with mineral granules and on the underside with a self -adhering compound and release film. 4.1.2 LeakBarrierO MS300 Ice and Water Armor is a self -adhering, glass mat reinforced, mineral surfaced, SBS modified roof underlayment. 4.1.3 eakBarrierO PS200HT Ice and Water Armor is a self -adhering, glass mat reinforced, fabric surfaced, SBS modified roof underlayment. Exterior Research and Design, LLC. Evaluation Report 10880.07.08-R4 Certificate of Authorization #9503 FL10450-R4 Revision 4: 02/25/2013 Page 2 of 9 TRINITY j ERA 4.1.4 LeakBarrier® PS200N10 Ice and Water Armor is a self -adhering, glass mat reinforced, smooth poly film surfaced, SBS modified roof underlayment. 4.1.5 LeakBarrierO NR500HT is a self -adhering, plastic film surfaced, modified underlayment. 4.1.6 LeakBarrier® SS400 Ice and Water Armor is a self -adhering, fiberglass reinforced, smooth surfaced modified underlayment. 4.2 Mechanically Fastened Underlavments: 4.2.1 Tarco 15 is an ASTM D226 Type I, 15 lb asphalt -saturated organic felt 4.2.2 Tarco 30 is an ASTM D226 Type II, 30 lb asphalt -saturated organic felt 4.2.3 Tarco NO 15 is an ASTM D4869 Type I asphalt -saturated organic felt 4.2.4 Tarco NO 30 is an ASTM D4869 Type II asphalt -saturated organic felt 4.2.5 LeakBarrierO EasyLay® is an asphalt -coated polyester fabric roof underlayment. 4.3 Mechanically Fastened and/or Bonded Underlavments: 4.3.1 Fiberglass Mineral Surfaced Roll Roofing is an ASTM D3909, glass -fiber -reinforced, asphalt - coated, granule surfaced underlayment used as a valley liner. 4.3.2 ASTM Organic Mineral Surface Tile Underlayment is an ASTM D6380, Class M asphalt - saturated organic roll roofing sheet. 4.3.3 LeakBarrier® EasyMopTM SBS is a polyester reinforced, SBS modified bitumen roofing underlayment. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop Tarco underlayments are follows: Underlayment Asphalt Shingles Nail -On Tile Foam -On Metal wood Shakes State Tile & Shingles LeakBarrier Fast90 Yes Yes Yes No Yes Yes See 5.4.2 LeakBarrier MS300 Yes No No No Yes Yes LeakBarrier PS200"T Yes Yes Yes Yes Yes Yes See 5.4.2 LeakBarrier PS200mu Yes No No Yes Yes Yes Yes LeakBarrier NR500"T Yes No No (No copper or Yes Yes zinc) LeakBarrier SS400 Yes No No No Yes Yes LeakBarrier EasyLay Yes Yes No Yes Yes Yes Tarco 15 Yes No No Yes Yes No Tarco 30 Yes Yes No Yes Yes Yes Tarco NO 15 Yes No No Yes Yes Yes Exterior Research and Design, LLC. Evaluation Report 10880.07.08-114 Certiflcate ofAuthorizaUon #9503 FL10450-114 Revision 4: 02/25/2013 Page 3 of 9 QOTRINITYIERD Underlayment Asphalt Nail -On Tile Foam -On Metal Wood Shakes Slate Shingles Tile & Shingles Tarco NO 30 Yes No No Yes Yes Yes Fiberglass Mineral Surfaced Roll Yes - Valley Liner per 1507.2.9.2, Section 2 Roofing ASTM Organic Yes Mineral Surface Tile Yes Yes No Yes Yes Underlayment See 5.4.2 LeakBarrier EasyMop Yes Yes Yes No Yes Yes SBS See 5.4.2 5.4.1 Tarco 15, Tarco 30, Tarco NO 15, Tarco NO 30 and EasyLay may be used as a mechanically attached base layer followed by a LeakBarrier self -adhering top layer or asphalt -applied ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS with allowable roof covers noted above for the respective LeakBarrier® self -adhering underlayments. 5.4.2 "Foam -On Tile" is limited to use of Polyfoam PolyPro AH160 applications unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. 5.5 Allowable substrates are noted below: 5.5.1 LeakBarrier Self -Adhering Direct -Bond to Deck: ➢ New untreated plywood; ➢ ASTM D41 primed new untreated plywood; ➢ Existing plywood; ➢ ASTM D41 primed existing plywood; ➢ Structural concrete ➢ ASTM D41 primed structural concrete. Note: Tarco does not require priming of new or existing plywood sheathing. New or existing plywood sheathing should be cleaned of all dirt and debris prior to application of LeakBarrier membranes. ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS Direct -Bond to Deck: ➢ ASTM D41 primed structural concrete. 5.5.2 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320 does not address wind uplift resistance of direct -deck, adhered underlayment systems beneath foam -on tile systems, where the bonded underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck, adhered LeakBarrier underlayment systems. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design pressures. 5.5.2.1 Maximum Design Pressure = -217.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Underlayment: LeakBarrier PS200"T, self -adhered. 5.5.2.2 Maximum Design Pressure = -75.0 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ, but not less than max. 24-inch spans with 8d ring shank nails spaced 6-inch O.C. Primer: (Optional) ASTM D41 Underlayment: LeakBarrier PS200"T, self -adhered. Exterior Research and Design, LLC. Evaluation Report 10880.07.08-R4 Certificate of Authorization #9503 F11-10450-114 Revision 4: 02/25/2013 Page 4 of 9 QOTImNITY1 ERD 5.5.3 Bond to Mechanically Attached Base Underlayment: ➢ LeakBarrier self -adhered to: ASTM D226, Type I or II felt; ASTM D4869 felt; LeakBarrier EasyLay. ➢ ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMOp SBS in hot asphalt to: ASTM D226, Type I or II felt; ASTM D2626 felt or ASTM D4601, Type II base sheet. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on the systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.5.4 LeakBarrier Self -Adhering Bond to Other Substrate Types: ➢ ASTM D41 primed metal (flashing metal, valley metal, etc.) 5.6 Exposure Limitations: 5.6.1 LeakBarrier EasyLay, FAST 90, ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier EasyMop SBS shall not be left exposed for longer than 180-days after installation. 5.6.2 LeakBarrier PS200HT shall not be left exposed for longer than 120-days after installation. 5.6.3 LeakBarrier MS300, NR500"T, PS200Mu or SS400 shall not be left exposed for longer than 30- days after installation. 5.6.4 Tarco 15, Tarco NO 15, Tarco 30 and Tarco NO 30 shall be covered as soon as possible after installation; exposure for more than 24 hours after installation could adversely affect performance. 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of 02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems. Table 2: Tile System Options per FRSA/TRI 07320 8-05 System Underlay O tion Section Reference Product(s) 1 3.02A 90# Organic Cap Sheet or Modified ASTM Organic Mineral Surface Tile Underlayment Cap Sheet or LeakBarrier EasyMop SBS System One: Base Layer: Tarco 30 Mechanically 2 3.02B No. 30 / 90# Organic or Modified Cap Top Layer: ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS Fastened Tile, Unsealed or Base Layer: Tarco 30 Sealed 3 3.02C No. 30 / 90# Organic or Modified Cap Top Layer: ASTM Organic Mineral Surface Tile Underlayment Underlayment or LeakBarrier Eas Mo SBS System 4 3.02D No. 30 Tarco 30 or Eas La 5 3.02E Self -Adhered Underlayment Fast 90 or PS200 6 3.02F No. 30 / Self -Adhered Underlayment Base Layer: Tarco 30 or EasyLay Top Layer: Fast 90 or PS200 1 3.02A 90# Organic Cap Sheet or Modified ASTM Organic Mineral Surface Tile Underlayment Cap Sheet or LeakBarrier EasyMop SBS Base Layer: Tarco 30 System Two: 2 3.02B No. 30 / 90# Organic or Modified Cap Top Layer: ASTM Organic Mineral Surface Tile Mechanically Underlayment or LeakBarrier EasyMop SBS Fastened Tile, Base Layer: Tarco 30 Sealed 3 3.02C No. 30 / 90# Organic or Modified Cap Top Layer: ASTM Organic Mineral Surface Tile Underlayment Underla ment or LeakBarrier EasyMop SBS System 4 3.02D Self -Adhered Underlayment Fast 90 or PS200 5 3.02E No. 30 / Self -Adhered Underlayment Base Layer: Tarco 30 or EasyLay Top Layer: Fast 90 or PS200 Exterior Research and Design, LLC. Evaluation Report 10880.07.08-R4 CertiFCate of Authorization #9503 FL10450-114 Revision 4: 02/25/2013 Page 5 of 9 Q0TPt.1N1TYJERD Table 2 (continued): Tile System Options per FRSA/TRI 07320/8-05 System Underlany Optio Section Reference Product(s) System Three: Base Layer: Tarco 30 Mortar Set 1 3.02A No. 30 / 90# Organic or Modified Cap Top Layer: ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS 1 3.02A 90# Organic Cap Sheet or Modified ASTM Organic Mineral Surface Tile Underlayment System Four Cap Sheet or LeakBarrier EasyMop SBS A': Base Layer: Tarco 30 Adhesive -Set 2 3.02B No. 30 / 90# Organic or Modified Cap Top Layer: ASTM Organic Mineral Surface Tile Tile, Unsealed or Underlayment or LeakBarrier EasyMop SBS Sealed Underlayment 4 3.026 Self -Adhered Underlayment Fast 90 or PS200"r 5 3.02E No. 30 / Self -Adhered Underlayment Base Layer: Tarco 30 or EasyLay System Top Layer: Fast 90 or PS200 System Four Base Layer: Tarco 30 "B": 1 3.02A No. 30 / 90# Organic or Modified Cap Top Layer: ASTM Organic Mineral Surface Tile Adhesive -Set Underlayment or LeakBarrier EasyMop SBS 3 3.02C Self -Adhered Underlayment Fast 90 or PS200HT Tile, Sealed Underlayment System 4 3.02D No. 30 / Self -Adhered Underlayment Base Layer: Tarco 30 or EasyLay Top Layer: Fast 90 or PS200"T 6. INSTALLATION: 6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and primed the substrate (if applicable). 6.3 LeakBarrier® Fast90@ Self -Adhering Tile Underlayment: 6.3.1 EasyLay shall be installed in compliance with the requirements for 90# felt underlayment (except the product is self -adhered) in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For use in non -tile aoolications: 6.3.2.1 Cut the Fast90 roll into 12' to 16' sections for workability and allow to relax prior to application. 6.3.2.2 Chalk a plumb line 36" from all outside perimeters; then chalk plumb lines 32" apart, upslope to the ridge line. 6.3.2.3 Membrane Application: ➢ Place a full width piece of Fast90 on the prepared substrate, parallel to the eave edge of the roof, with the selvedge edge positioned upslope and in -line with the ist chalk line. ➢ Fold back half the sheet and remove the exposed release film, taking care not to displace the membrane ➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles and ridges, and repeat for the other half of the sheet. ➢ Remove selvage release film, if present, and install capped or tin tagged nails 6" o.c. in the center of the selvedge edge. ➢ Install the subsequent sheets in the same manner, with upslope selvedge edges in -line with chalk lines, with 4" side laps and 8" end laps. ➢ Seal all 8" end laps 1/16" thick application of asphalt plastic cement and stagger all end laps minimum 36". ➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave / rake areas to ensure a complete bond. Exterior Research and Design, LLC. Evaluation Report 10880.07.08-R4 Certificate of Authorization #9503 FL10450-R4 Revision 4: 02/25/2013 Page 6 of 9 1 QOTRINi-rYIERD 6.3.4 For use in the applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.3.4.1 Wait a minimum of 24 hours prior to loading roof tiles. 6.3.4.2 All tiles shall be staged four tiles perpendicular to slope, six tiles on top, parallel to slope; not to exceed 10 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. 6.3.4.3 At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal batten. 6.4 LeakBarrierp MS300, PS200HT, PS2001Nu, NR50ONT or SS400 Ice and Water Armor: 6.4.1 MS 300, PS200"T, PS200mu, NR500HT or SS400 shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For use in non -tile applications: 6.4.2.1 Cut MS 300, PS200 "T, PS200Mu, NR500HT or SS400 to manageable sections and allow to relax prior to application. 6.4.2.3 Membrane Application: ➢ Place a full width piece on the prepared substrate, aligned parallel to the eave edge and extend approximately 3/8" over the eave and rake with the selvedge edge positioned upslope. ➢ Fold back the upslope half of the sheet and remove the exposed release film, taking care not to displace the membrane ➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles and ridges ➢ Apply a 1/16" thick layer of asphalt plastic cement over the eave and rake metal, extending 2" to 3" onto the deck surface. ➢ Fold back the downslope half of the sheet, remove the release film and roll the membrane onto the substrate from the centerline out. ➢ Seal all 6" end laps with a 1/16" thick application of asphalt plastic cement and stagger all end laps minimum 36". ➢ Remove selvage release film, if present, and install second and subsequent courses in a similar manner. ➢ Install capped or tin -tagged nails 6" o.c. along the centerline of the laps. ➢ At all T-joints, where an end -lap and the next overlapping course intersect, apply a bead of roofing laps cement before the overlapping course is laid. ➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave / rake areas to ensure a complete bond. 6.4.4 For use in tile applications (PS200"T only, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4.4.1 Wait a minimum of 24 hours prior to loading roof tiles. 6.4.4.2 All tiles shall be staged four tiles perpendicular to slope, six tiles on top, parallel to slope; not to exceed 10 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. 6.4.4.3 At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal batten. Exterior Research and Design, LLC. Evaluation Report 10880.07.08-R4 Certificate of Authorization #9503 FL10450-114 Revision 4: 02/23/2013 Page 7 of 9 6.5 Tarco 15 and 30: TRINITY I ERD 6.5.1 Tarco 15 and 30 shall be installed in compliance with the requirements for ASTM D226, Type I and II underlayments, respectively, in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.5.2 For use in non -tile applications reference is made to the current edition of the NRCA Steep - slope Roofing Manual. 6.5.3 For use in the applications (Tarco 30 only, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.6 Tarco NO 15 and NO 30: 6.6.1 Tarco NO 15 and NO 30 shall be installed in compliance with the requirements for ASTM D4869 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.6.2 For use in non -tile applications, reference is made to the current edition of the NRCA Steep - slope Roofing Manual. 6.6.3 Not for use in tile applications. 6.7 LeakBarrier EasyLay: 6.7.1 EasyLay shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.7.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.7.3 For use in non -tile applications: 6.7.3.1 Place a full width section of EasyLay, parallel to the eave edge of the roof and unroll 2 to 3 feet with the lay lines facing up, and position to the edge of the eave and rake. Install a few fasteners at the top, near the rake, and roll out the sheet to a manageable length. Pull, straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge. Fasten with 3/8" headed roofing nails or 1" capped (plastic or metal) nails, driven by hand or pneumatically, spaced 6" o.c. at all laps in the center of the seam area, and two staggered rows fastened 12" o.c. in the field of the sheet. Install nails such that the head of the nail is flush with the surface, without cutting into the surface. Fasten from the top to avoid walking or kneeling on unsecured sheet. Continue to the end of the substrate and fasten down. Align the next roll over the preceding sheet so as to form a minimum 4", water -shedding lap, and install per instructions above. Apply subsequent sheets in the same manner, with minimum 4" water -shedding laps and minimum 8" end - laps, which are staggered minimum 36" fro the preceding course. For double layer applications, follow the instructions noted above, but using a minimum 19", water -shedding side lap. 6.7.3.2 Allow for minimum 6" up the vertical transitions.and minimum 6" over hips and ridges. 6.7.3.3 At valleys, first install a vertical length of EasyLay down the center of the valley, then start at the low point and work to the high point, rolling the membrane from the center outward in each direction, ensuring no wrinkles or tears. Covered with valley -metal or other valley lining material in accordance with NRCA recommendations. 6.7.3.4 Apply a thin coat of asphalt plastic cement to waterproof areas where any cuts or tears have occurred. Seams or joints that require adhesive or sealant can be treated with high quality plastic cement (asbestos free). 6.7,4 For use in tile applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. Exterior Research and Design, LLC. Evaluation Report 10880.07.08-114 Certificate of Authorization #9503 FL10450-114 Revision 4: 02/25/2013 Page 8 of 9 �l w TRINITY J ERD 6.8 ASTM Organic Mineral Surface Tile Underlayment: 6.8.1 Shall be installed in compliance with the requirements for ASTM D6380, Class M sheets in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.8.2 For use in non -tile applications, reference is made to the current edition of the NRCA Steep - slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings. 6.8.3 For use in tile applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 5.7 herein. Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. 6.9 LeakBarrierim EasyMop SBS: 6.9.1 Shall be installed in compliance with current Tarco published installation requirements, subject to the limitations herein. 6•9•2 Non -Tile Applications: 6.9.2.1 For mechanically attached applications: Secure LeakBarrier EasyMop SBS using 3/8-inch headed roofing nails or 1-inch diameter cap -nails spaced 9-inch o.c. within the 4-inch wide side laps and 12-inch o.c. in two (2) equally spaced, staggered center rows in the center of the sheet. End -laps shall be minimum 6-inch wide, and offset end -laps minimum 3-feet from course to course. Seal end laps in accordance with Tarco requirements. 6.9.2.2 For bonded applications: Fully adhere LeakBarrier EasyMop SBS in hot -asphalt to the substrates noted in Section 5.5. Side laps shall be minimum 4-inch and end -laps minimum 6-inch wide, and offset end -laps minimum 3-feet from course to course. Side and end -laps. shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. Consult Tarco instructions regarding back - nailing requirements. 6.9.3 Tile Applications: 6.9.3.1 Refer to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition and Table 2 herein. 6.9.3.2 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements 10 QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. CertiFcate of Authorization #9503 Evaluation Report 10880.07.08-R4 FL10450-R4 Revision 4: 02/25/2013 Page 9 of 9