HomeMy WebLinkAboutSUBMITTED PAPERSPLANNING & DEVELOPMENT SERVICES DEPARTMENT
BUILDING & CODE REGULATIONS DIVISION
a. a
2300 Virginia Avenue SCANNED
Fort Pierce, FL 34982 BY
772-462-1553 St. Lucie County'
APPLICATION FOR STORM SHUTTER PERMIT
1. LOCATION/SITE ADDRESS:--? (p q 6E 9' (2,er Low e, 0 L, )L 3 42-3
2. PARCEL ID NUMBER:
3. DESCRIPTION OF PRO
4. TYPE OF STRUCTURE: SFR: ?�
5. OWNERS INFORMATION
MOBILE HOME: OTHER:
NAME: NIi"ad E&(Qer tTi2) l2csem&.;
ADDRESS: -? (-O q C i U'e� C avt >_
CITY: P2, L STATE: I- L
ZIP CODE: 4 PHONE: j';,S 10,56
EMAIL:
Type of Surface attachment: Wood Frame
6. CONTRACTOR'S INFORMATION
Ed�,er�Tr� FL REGISTRATION/CERT #:
COUNTY CERT #: I-Iq 'o? -Q
BUSINESS NAME:
PHONE NUMBER: 7 2 Q- V 7 3- bloQ�
EMAIL:
Concrete Masonry
Other
PRODUCT TYPE
PRODUCT DESIGN PRESSURE
PRODUCT APPROVAL #
REMOVABLE PANELS
t rj -#
ACCORDION
ROLL -UP
FABRIC
OTHER
[ I ATTACH 2 COPIES OF THE PRODUCT APPROVAL WITH DETAILS TO THE PRODUCT BEING USED.
ALL PRODUCTS SHALL BE LABELED FOR DETERMINING IMPACT RESISTANCE FROM WIND BORNE DEBRIS. **SEE FINAL INSPECTION
PROCEDURE FOR EXISTING RESIDENTIAL STRUCTURES ON BACK.
7. VALUE OF CONSTRUCTION: $ 45YO,` PEIjMIT FEE: $
OWNER'S AFFIDAVIT: I certify that all of the information contained in this
compliance with all applicable laws regulating construction and zoning.
that all work will be done in
_6row n Jc hn s6h -Tr-- • S--
PRINT NAME OF OWNER OR CONTRACTOR/QU LI,FIEeR SIGNATURE OF OWNER O CONTRACTOR/QUALIFIER
STATE OF FLORIDA, COUNTY OF � �J (ZC �,
ACKNOWLEDGED BEFORE ME THIS J-0 DAY 6� 206Y, `�J► `-� 9.�i � `MZ IS�LLY KNOWN TO ME
HO HAS PRODUCE ` `SI IF 1
„ p
SIGNATURE OF N ARY TYPE OR PRINT N�j L TAR eSXpI� adN . Et: 083 I SEAL
TITLE: NOTARY P LIC COMMISSION NUA 1p 20j53
NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR
NOTICE OF COMMENCEMENT.
SLCPDSD Revised 4/10/2012 JC
Property Appraiser - St.Lucie County, FL
Michael A Eger (TR)
Record: 1 of 1
Property Identification
Site Address:
764 SE RIVER LN
Sec/Town/Range:
27 :36S :40E
Map ID:
34/27S
Zoning:
RS-3
PROPERTY RECORD CARD
«Prey Next» Spec.Assmnt Taxes
ParcellD:
3427-701-0060-000-0
Account *:
115540
Use Type:
SF Res
City/Cnty:
Saint Lucie County
Ownership and Mailing
Owner: Michael A Eger JR) Rosmarie H Eger JR)
Address: 764 SE River Ln
Port St Lucie FL 34983
Page 1 of 1
Exemptions Permits Home Print
e` UCIEC0
Legal Description
HIDDEN RIVER ESTATES BLK 3 LOT 25 (OR 3350-2404; 3501-601: 3532-32
THRU 37)
Sales Information
Assessment 2013
Date
Price
Code
Deed
Book/Page
2013 Final:
149700
6/12/2013
100
0111
WD
3532 / 0036
Assessed:
149700
6/12/2013
100
0111
WD
3532 / 0035
Ag.Credit:
0
6/12/2013
100
0111
WD
3532 / 0034
Exempt:
6/12/2013
100
0111
WD
3532 / 0033
Taxable:
6/4/2013
100
0111
WD
3532 / 0037
Taxes:
3031.77
3/29/2013
0
0111
PB
3501 / 0601
3/14/2013
165000
0111
WD
3532 / 0032
11/29/2011
120000
0001
WD
3350 / 2404
11/17/2006
315000
00
WD
2712 / 1968
7/21/2005
327000
00
WD
2311 / 2463
7/29/2003
244700
00
WD
1766 / 1503
6/27/1996
160000
02
WD
1023 / 0947
10/20/1988
12:00:01 AM
174500
00
WD
0608 / 1691
10/20/1988
174500
00
WD
0608 / 1691
10/1/1979
18500
00
CV
0319 / 1558
5/1/1978
0
01
CV
0286 / 1827
BUILDING INFORMATION
Total Land and Building
Land Value: 45900 Acres: 0.44
Building Value: 103800
Finished Area: 1996 SgFt
Exterior Features
View:
RoofCover:
DS - Cedar Shingl
RoofStruct:
HP - Hip
ExtType:
HC - HC
YearBlt:
1980
Frame:
Grade:
C - C
EffYrBlt:
1980
PrimeWall:
BS - CB Stucco
StoryHght:
0010 -1
Story
No.Units:
1
SecWall:
PS - Perma Stone
Interior Features
Bed Rooms:
3
Electric:
MX - MAXIMUM
PrmintWall:
DW - Drywall
FullBath:
2
HeatType:
FHA - FrcdHotAir
AvgHt/Fl:
1/2Bath:
0
HeatFuel:
ELEC - Electric
Prm.Flors:
CU - Carpet
%A/C:
100
%Heated:
100
%Sprinkled:
0
Special Features and Yard Items
Land Information
Type
Y/S
Qty.
Units
Qual. Cond.
YrBlt.
No. Use Type
Type
Measure Depth
SWAV - RES POOL AVG
Y
1
648
AV AV
1982
1 0100-SF Res
275 -Front Ft
108 178
PA01 - POOL DK-AVG
Y
1
1052
AV AV
1982
DWC - Driv-Concret
Y
1
1020
AV AV
1980
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
http://www.paslc.org/paslc/prc.asp?prclid=342770100600000 1/6/2014
Florida Building Code Online
F10'du ii2pdittTienta BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff
Busines
)rofessi "al PER: uccUApproval
ser
Regulation
MMMETTIMOMM Product Approval Menu > Product or Application Search > Application Lis[ > Application Detail
A e FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL12856-R4
Revision
2010
Approved
Town and Country Industries,
400 West McNab Road
Ft. Lauderdale, FL 33309
(954)493-8551
tomj@tc-alum.com
Frank Bernardo
frank@engexp.com
Thomas B. Johnston
400 west McNab Rd.
Ft. Lauderdale, FL 33309
(954)970-9999
tomj@tc-alum.com
Shutters
Storm Panels
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Frank I. Bennardo
PE-0046549
National Accreditation nd n ement Institute
12/31/2013
ORLANDO L. BLANCO, P.
Validation Checklist -rdcopy Received
FL12856 R4 COI Cert Inf
FL12856 R4 COI Cert Indeo2.odf
FL12856 R4 COI Cert Indeo3.odf__
Standard
ASTM E1886
ASTM E1996
ASTM E330
TAS 201
TAS 20
TAS 203
Year
2002
2002
2002
1994
1994
1994
http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvEm 1 fWvK4bEBhusG5`/o2bcgdce... 1/6/2014
Florida Building Code Online
Sections from the Code
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method i Option D
10/25/2013
10/25/2013
10/29/2013
12/13/2013
..._.- .... ....._......_...-- -
Summary of Products
FL # 11IModel, Number or Name
Description
12856.1 0.050" Aluminum Storm Panel
0.050" Aluminum Storm Panel with Optional Clear Panels
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12856 R4 II DwD09.1)df
Approved for use outside HVHZ: Yes
Verified By: Frank L. Bennardo, P.E. PE0046549
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Shutter meets requirements for "Wind Zone 4" and Missile
"D"
FL12856 R4 AE 02-09.odf f
Level as defined in ASTM E1996. See installation instructions for
FL12856 R4 AE Eval rot09.Ddf
specific Design Pressure Ratings by size, additional use limitations
Created by Independent Third Party: Yes
6-w_0qiTs-r571Xlon instructions.
12856.2
"Safety Edge" Storm Panels
"Safety Edge" Storm Panels, 28ga (0.018"") Steel, 0.022" Alum (Perf
and Non -Pert), Clear Polycarb (Full and Half)
LftimIrs—of Use
Installation Instructions
Approved for use in HVHZ: No
FL12856 R4 II Dwo3.odf
Approved for use outside HVHZ: Yes
Verified By: Frank L. Bennardo, P.E. PE0046549
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: +54/-54
Evaluation Reports
Other: This product is not valid for use within the HVHZ. See
FL12856 R4 AE Eval Rot3.Ddf
Evaluation Report and engineering drawing for additional limitations
Created by Independent Third Party: Yes
and conditions of use.
12856.3 0.050" Aluminum Storm Panel
0.050" Aluminum Storm Panel with Optional Clear Panels
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12856 R4 II Dwo2.Ddf
Approved for use outside HVHZ: Yes
Verified By: Frank L. Bennardo, P.E. PE0046549
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Shutter meets requirements for "Wind Zone 4" and Missile
FL12856 R4 AE Eval RDt2.odf
Level "D" as defined in ASTM E1996. See installation instructions for
Created by Independent Third Party: Yes
specific Design Pressure Ratings by size, additional use limitations
j and installation instructions. 11
i 12856.4 Aluminum Hinged Storm Panel
.050" Aluminum Non -Porous Hinged Storm Panel
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12856 R4 II Dwo.Ddf
Approved for use outside HVHZ: Yes
Verified By: Frank L. Bennardo PE#0046549
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Shutter meets requirements for "Wind Zone 4" and Missile
FL12856 R4 AE Evai RDt.odf
"D" as defined in ASTM E1996. See installation instructions for
Created by Independent Third Party: Yes
Eevel
pecific Design Pressure Ratings by size, additional use limitations
nd installation instructions.
Back Next
Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity.
Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October
1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication
with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made
available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
W W, tC;i MW
secutyt a vrnec:s
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvEm 1 f WvK4bEBhusG5%2bcgdce... 1 /6/2014
"SAFETY EDGE" & POLYCARB STORM PANELS
28ga (0.018") STEEL & 0.100" POLYCARB
�-2-j 0.018" GALV STEEL PERFORATIONS 0.01B" GALV STEEL
(OPTIONAL) �`
v0,378" ` ` -SAFETY EGE O
0.378" / PERFORATIONS
a N ? y 2. Dj- y N 1 (OPTINAL)
try ps 1.125" (1/4" TYP) tr`'% rS SAFETY EDGE
1 i ti D>\Y ft 1.25'tII KK//,y- Fs �� �JII �'1°-1 ry•
4" I P.t1.25°I (1/4., TYP)
4.844.84h" � x0.378" T�`-4�._...-._-._
12° COVERAGE +C �-�--6" COO
VERAGE-- � -} 0.378"
33.5"TOTAL WIDTH 7.531"TOTAL WIDTH
1a STEEL STORM PANEL PROFILE 1b STEEL HALF -PANEL PROFILE
4° = 1'•0" SECTION 4° = 1'-0" SECTION
2„� 0.100" POLY- �2"
CARBONATE 0100"POLY-
(t0.070") 9ml.
ARBONATE216° 1.216"�f0.010")1t-1.5"--t00".._...._ .y.-5.000_"12.5" COVERAGE---------
15" TOTAL WIDTH ------ ---
POLYCARB STORM PANEL PROFILE n POLYCARB HALF -PANEL PROFILE
1c 4" = 1'-0" SECTION lJ 4" = 1'-0" SECTION
3/161�f- �. 0.085" MIN
WIDTH UNLIMITED D D `�., ( ! 0,875" THICKNESS
TOP MOUNT MOUNTING --.> j <a I I i _ 05/16"
(CONK AS REQ'D) SECTIONS i ti D D D 1/2"j cC! 1/4-20 STUDS
o '4Z..'Fw!� AT 12" O.C. (n
.....:....
D 0 O80" TYP
OPTIONAL �_ 2.0D0"-4
i I z PERFORATIONS KEYHOLE
_vEEWS 1 3"=1'-D" ELEV Z STUDDED ANGLE 3 WASHER
z j
z0
F I ' 3/8" \
5/8"
a
°
Iti
BOTTOM MOUNT !-------------_`- ' ALUMINUM STEEL] -PAN
(CONN AS REQ'D) '---�-
CLOSURE CLOSURE
1 TYPICAL ELEVATION 3 KEYHOLE PUNCH 4 4"=r-o" 5 4"=1-11"
1 N.T.S. 1 6" = 1'-0. ELEV
GENERAL NOTES:
1) THIS SYSTEM HAS BEEN TESTED AND EVALUATED AS A LARGE
MISSILE IMPACT PROTECTIVE SYSTEM IN ACCORDANCE WITH THE
REQUIREMENTS OF THE FLORIDA BUILDING CODE, CURRENT
EDITION, FOR USE OUTSIDE THE HIGH VELOCITY HURRICANE
-LONE PER ASTM STANDARDS E330, E3886, & E1996.
2) N0.33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN
USED IN THE DESIGN OF THIS PRODUCT. WIND LOAD DURATION
FACTOR Cd=1.6 HAS BEEN USED FOR WOOD ANCHOR DESIGN,
3) POSITIVE AND NEGATIVE DESIGN PRESSURES CALCULATED
FOR USE WITH THIS SYSTEM SHALL BE DETERMINED PER
SEPARATE ENGINEERING IN ACCORDANCE WITH THE GOVERNING
CODE. PRESSURE REQUIREMENTS AS DETERMINED IN
ACCORDANCE WITH ASCE 7-10 AND CHAPTER 1609 OF THE 2010
FLORIDA BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE
POSITIVE OR NEGATIVE DESIGN PRESSURE CAPACITY VALUES
LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN.
4) DESIGN PRESSURES NOTED HEREIN ARE BASED ON MAXIMUM
TESTED PRESSURES DIVIDED BY A 1.5 SAFETY FACTOR.
5) THE SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT
PROVIDE INFORMATION FOR A SPECIFIC SITE. IF SITE
CONDITIONS DEVIATE FROM THE CONDITIONS DETAILED HEREIN,
A LICENSED ENGINEER OR REGISTERED ARCHITECT SHALL
PREPARE SITE SPECIFIC DOCUMENTS TO BE USED IN
CONJUNCTION WITH THIS DOCUMENT.
6) THE ADEQUACY OF THE EXISTING STRUCTURE TO WITHSTAND
SUPERIMPOSED LOADS IS OUTSIDE THE SCOPE OF THIS
CERTIFICATION AND SHALL BE VERIFIED BY OTHERS.
7) CLEAR POLYCARBONATE PANELS SHALL BE ALTERNATED WITH
0.018" (MIN) GALV STEEL PANELS SUCH THAT NO TWO
POLYCARBONATE PANELS ARE ADJACENT TO EACH OTHER.
8) ALL PANELS SHALL BE INSTALLED USING KEYHOLE WASHERS
IN CONJUNCTION WITH ALL MOUNTING CONDITIONS.
9) ALL GALV STEEL STORM PANELS SHALL HAVE MIN
GALVANIZED THICKNESS t=0.018" CONFORMING TO ASTM A653,
STRUCTURAL QUALITY GRADE 40, WITH G60 GALVANIZED
COATING AND MIN FY=44.58 KSI.
10) CLEAR POLYCARBONATE STORM PANELS WITH 12.5"
COVERAGE SHALL BE MFD BY TRANSPARENT PROTECTION
SYSTEMS, Inc., AND THOSE WITH 6.25" COVERAGE SHALL BE
MANUFACTURED BY TOWN & COUNTRY INDUSTRIES, Inc. ALL
POLYCARB PANELS SHALL BE EXTRUDED WITH MIN THICKNESS
t=0.100° (30.010°) AND SHALL BE FABRICATED FROM 100% G.E.
SYNTHETIC THERMOPLASTIC POLYMER LEXAN RESIN #103.112 (UV
STABILIZED) OR EQUIVALENT. THIS MATERIAL IS COMPARABLE TO
G.E. LEXAN POLYMER SHEET 59034, AS APPROVED UNDER
MIAMI-DADE COUNTY NOTICE OF ACCEPTANCE #03-0924.01.
MINIMUM SYNTHETIC THERMOPLASTIC POLYMER TENSILE
STRENGTH Fy-8.908 KSI, FLEXURAL STRENGTH Fby=12.90 KSI, &
FLEXURAL MODULUS IS 328.7 KSI.
11) ALL EXTRUSIONS SHALL BE 6063-T6 ALUMINUM ALLOY,
UNLESS NOTED OTHERWISE.
12) PANELS SHALL BE PERMANENTLY LABELED WITH A MINIMUM
OF ONE LABEL PER PANEL AS FOLLOWS:
TOWN & COUNTRY INDUSTRIES
FT. LAUDERDALE, FL-
ASTM E1886, E1996 & E330 MISSILE LEVEL D
FLORIDA PRODUCT APPROVAL NUMBER
13) STORM PANELS HAVE BEEN DESIGNED AND TESTED TO THE
MAXIMUM SPANS AND LOADS SHOWN ON THESE DRAWINGS.
REFERENCE CONSTRUCTION TESTING CORPORATION (CTC OF
MIAMI, FL) TEST REPORTS #04-004, 904.005, & #04-006.
14) TOP & BOTTOM DETAILS SHOWN MAY BE INTERCHANGED AS
FIELD CONDITIONS DICTATE. PANELS MAY BE MOUNTED
HORIZONTALLY WHERE APPLICABLE.
15) ALL BOLTS & WASHERS SHALL BE ZINC COATED STEEL,
GALVANIZED STEEL, STAINLESS STEEL, OR 2024-T4 ALUMINUM
ALLOY WITH A MINIMUM TENSILE YIELD STRENGTH OF 33 KSI.
05-TCM-0001
I
EXISTING HOST
STRUCTURE
y} MINIMUM -I
EXISTING I -SEPARATION 4
GLAZING-\ PER
SCHEDULE -T
ANCHOR PER
ANCHOR SCHED
a
114-20 x 3/4"
S.S STUDS
AT 12" O.C.
r 2 —11/4" MAX
-� OR PER ANCHOR
SCHEDULE
1 MOUNTING SECTION
lll2 3" = 1'-0"
SPAN SCHEDULE
28g0
(0.018") GALV STEEL PANELS
MAX LOAD: t54.a psf
MAX SPAN: 9'-2" (ALL MOUNTING CONDITIONS)
MIN SPANS: 26" (DIRECT MOUNT TOP & BOTTOM)
16" (ALL OTHER CONDITIONS)
0.100" CLEAR POLYCARB FULL -/HALF -PANELS
MAX LOAD: t54.0 psf
MAX SPAN: 9'-2" (ALL MOUNTING CONDITIONS)
MIN SPANS: 24" (DIRECT MOUNT TOP & BOTTOM)
15" (ALL OTHER CONDITIONS)
EXISTING HOST
STRUCTURE, TYP
�2" TO MAX �R<
C4 S
1/2" MIN MAX
\�
OVERLAP �- MAX
K-ANCHORS
FASTEN PANELS TO
AT 17" O.C. (USE ANY HOST STRUCTURE OR
ANCHOR FROM ANCHOR SCHED) TO STUDDED ANGLE
(TOP & BOTTOM) AT
2 TRAP MOUNT CLOSURE CORRUGATION VALLEY
3" = 1'-0' PLAN VIEW CLOSEST
TO CORNER
2(EEAACH SIDE)
MAX
1/4" MAX �/�
��TMAX r /
_- r77
EXISTING HOST
STRUCTURE
�3 WALL MOUNT CLOSURE
J 3" = 1'-(I" PLAN VIEW
GLASS SEPARATION
SCHEDULE
(REQUIRED ONLY IN ASTM WIND ZONE 4 AND
ESSENTIAL FACILITIES)
28ga (0.01 I") GALV STEEL PANELS
• MIN. GLASS SEPARATION FOR INSTALLATIONS
AT OR BELOW 30' ABOVE GRADE: 5.375"
• MIN. GLASS SEPARATION FOR INSTALLATIONS
GREATER THAN 30' ABOVE GRADE: 5,375"
0.100" CLEAR POLYCARS FULL -/HALF -PANELS
• MIN. GLASS SEPARATION FOR INSTALLATIONS
AT OR BELOW 30' ABOVE GRADE: 7.350"
MIN. GLASS SEPARATION FOR INSTALLATIONS
GREATER THAN 30' ABOVE GRADE: 5.375"
BEND PANEL AROUND
CORNER & STITCH TO
ADJACENT PANEL
WITH 114-20 BOLTS
& WASHERED
WINGNUTS AT 24"
O.C. (TYP)
EXISTING HOST
\ STRUCTURE
4 CORNER CLOSURE
2 N.T.S. PLAN VIEW
GLASS SEPARATION
SCHEDULE NOTES:
1. GLASS SEPARATION SCHEDULE
PROVIDES MINIMUM SEPARATION
DISTANCE REQUIRED BETWEEN EXTERIOR
FACE OF GLAZING (OR OTHER PRODUCT
BEING PROTECTED) AND INTERIOR FACE
OF INSTALLED STORM PANEL.
2. SEPARATION DISTANCE PER THIS
SCHEDULE IS REQUIRED FOR USE WITH
POSITIVE LOADS ONLY.
3. SEPARATION FROM GLASS IS
REQUIRED ONLY WHEN INSTALLED
WITHIN ASTM WIND ZONE 4 AND
ESSENTIAL FACILITIES.
ANCHORS AT 17" D.C.
(USE ANY ANCHOR
FROM ANCHOR SCHED)
EXISTING HOST f
BUILD -OUT
5 MOUNT CLOSURE
2 3" = 1'-0" PLAN VIEW
05-TCM-0001
0
ANCHOR NOTES:
Its
1) "ELCO PANELMATE" ANCHORS MAY BE ELCO FEMALE
PANELMATE OR ELCO PANELMATE PLUS, AS ILLUSTRATED.
2) ENSURE MINIMUM 2" EDGE DISTANCE FOR ANCHORS
TO CONCRETE & TO HOLLOW BLOCK. EDGE DISTANCE OF
3/4" IS ACCEPTABLE FOR ANCHORS TO WOOD, WITH THE
EXCEPTION OF PANELMATE ANCHORS FOR WHICH 2" MIN
EDGE DISTANCE IS REQUIRED. FOR PANELMATES TO
WOOD WITH 3/4" MIN EDGE DISTANCE, ALLOWABLE
SPACING SHALL BE 6" O.C.
3) MINIMUM EMBEDMENT SHALL BEASNOTED IN
3 ANCHOR SCHEDULE. MINIMUM EMBEDMENT AND EDGE
DISTANCE EXCLl1DES STUCCO, FOAM, BRICK, AND OTHER
WALL FINISHES.
4) ANCHORS SHALL BE INSTALLED IN ACCORDANCE
WITH MANUFACTURERS' RECOMMENDATIONS.
5) ALL CONCRETE ANCHORS SPECIFIED HEREIN SHALL
'- BE INSTALLED TO NON -CRACKED CONCRETE ONLY.
R 6) WHERE EXISTING STRUCTURE IS WOOD FRAMING,
EXISTING CONDITIONS MAY VARY. FIELD VERIFY THAT
FASTENERS ARE INTO ADEQUATE WOOD FRAMING
€ MEMBERS, NOT PLYWOOD.
7) WHERE ANCHORS FASTEN TO NARROW FACE OF
STUD FRAMING, ANCHOR SHALL BE LOCATED IN CENTER
OF NOMINAL 2x4 (MIN) WOOD STUD (i.e. 3/4' EDGE
DISTANCE 1S ACCEPTABLE FOR ANCHORS TO WOOD
FRAMING). WOOD STUD SHALL BE "SOUTHERN PINE"
G=0.55 OR GREATER DENSITY, UNLESS OTHERWISE
j NOTED.
y 8) ANCHOR SCHEDULE APPLIES FOR ALL PRODUCTS
CERTIFIED HEREIN, BUT ONLY PROVIDES MAXIMUM
ALLOWABLE ANCHOR SPACING. MAXIMUM ALLOWABLE
q SPANS AND PRESSURES INDICATED IN SPAN SCHEDULE
3 SHALL APPLY.
ES 9) MACHINE SCREWS SHALL HAVE MINIMUM OF 1/2"
ENGAGEMENT OF THREADS IN BASE ANCHOR AND MAY
S HAVE EITHER A PAN HEAD, TRUSS HEAD, OR WAFER
$g HEAD ("SIDEWALK BOLT") U.N.O.
5tl
ANCHOR SCHEDULE
bJ
Spans
5Pp0
Spans
9121.
ON
ANCHOR
(p=f)
1/4" ITW TAPCON W/ 1-3/4"
I6.0'
16:0"
EMBED (3192ps1 MIN COtJQ
.33
38
1..0
1 ...
.47
16.0"'
6:0"
54
16.0"
16.0"
4" ELC0 ULTRACON 1-314'
j 33
._.....
16.0"
.__
16.0"
BED (2846psi MIN CONC)
38
16.0"
16.0"
47 .
16.0"
¢
54
I6.0"
16.0"
0
u
/4" PANELMATE (PLUS OR
FEMALE) x 1-3/4" EMBED
33
- --
16.0"
_ I6.0' _
(3350ps1 MIN CONC)
- ....
-- -
- --
----3m12=m
47
I6.0
16AT'
Et--nncmm,
1/4' ALL POINTS SOLID -SET
33
16:0"
16:0"
ANCHOR x 7/8' EMBED
...
.... _
_
_ I6
(3000psI MIN CONC)
--
_
:0" -
awl: t
54
16.0"
1fi.0"
u
s v
i
LOAD
ANCHOR (psl)
Spans
4 0
Spans
9P-2'Up � j
1/4" ITW TAPCON W/ 1-1/4" 33
16.0"
9.9"
EMBED .........
39
......'...._
1�.8"
a-6"
..7.0^..
. 47'
_ 12 ":.
�� S4
j
i/4' ELCO ULTRACON VJ/ 33
16.0"
11.1"
1-1/4" EMBED .-._._F..._._._.
_...._._
J
0
1/4" PANELMATE (PLUS OR I 33
16.0"
16.0"
0
FEMALE) x 1.114" EMBED ? gg
16.0"
14.5"
D 47
16.0,
54
16.0..
10.._
1/4" ALL POINTSSOLID-SET ;; 33
16.0" 116.0"
ANCHOR x 7/8' EMBED . ""'
38
.....
16.0"
""
I6.0"
i _4
1 54
16.0"
13.9"
r�
0116-
1 ANCHOR
LOAD
050
Spans
Up To
Spans
Up To
1/4" TAPCON OR X 14 WOOD
33
16A"
SCREW x 2" EMBED
38�
16.0"
13.2"
16.0"
z..
f
tenon '""w
-47
54_..
R.10.7"
16.0"..9.3"
,n
o�
1/4" PANELMATE (PLUS OR
) x FEMALE1-7/8" EMBED
33
16.0" _
16.0"
II
U
J2- MIN EDGE DISTANCE)
38
""
47
16.0"
-""
16.0"
16.0"
"""-
16.0"
o
-lnrzarnm
54
I6.0'
w
o a
3N
1/4" LAG SCREW x 2"
33
-"-"'"
16.0"
---'--"--
15.5"
---
THREAD EMBED
38
16.0
13.4"
' EMBED i
47
._.,.....
16.0"
10.9"
_ .
9--
54
16.0"
...
9.5"
r
O1-
'LOAD
ANCHOR (Dsf)
Spans
Up TD
Spansi
UP TO
xu
5'-0"
9-2"
1/4' ITW TAPCON OR ELCO 33
16.0"
13.5"
ULTRACON x 2" EMBED 38
IG.O"
11.7"
54
15.1"
8.3"_
1/4" PANELMATE (PLUS OR 33
16.0"
13.1"
z
I
FEMALE) x 1.7/8" EMBED 38
(2" MIN EDGE DISTANCE) `
16.0"
11.4"
16.0"
9.2"
v
g 47
14.7"
o
u.
�1' RiIlVID 1 54
..................._._..........._..
B.G"
�u
l l/4" LAG SCREW x 2" 33
16.0"
16.0"
p
p w
1EM•BEDMENT
78
I6.0"
1G.0'
}EMBED 47
16.6"
13.5"
54
16.0"
11.8"
1/4" 13-8 STAINLESS STEEL 33
16.0"
16.0" I
HANGER BOLT x 2"EMBED --..
38
"-'-"'-
6.0"
'
16.0" j
}EMBED t '---...__
47
.. .....
16.0"
........._._
c .. Emmmazil.
05-TCM-0001
iCALE1 104
�GB DESCRIPTION: