Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSFbate.- Fee Due;, Permit # .11 I6- l ❑ Electrical ❑ Shed Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. Fort Pierce, FL 34982 (772)462-1553 'SX' SPECIALTY PERMIT APPLICATION ❑ Plumbing AC ❑ Fence ❑ Demolition ❑ Gas ❑ Siding Seepage 2 for instructions and additional paperwork required for specialty permits I 1. Location/Site Address: yy00 tf e4l'", x� �/L %®� � &0 61 2. Parcel ID Number: t� 4017 401� f OJffice Use Only Section Township Range Map Page Zoning Land Use Initials 3. Complete Description of Project or Work: L f �� �/ Q O�d �%' °'' S e. O, l3ke, 4. Owners Information �j 5. Contractors Information /�i Name: 6W l9�/( FL Reg/Cert #: C W C O J l81 0 Address: J a.vunJ6y `'`i `=' • • • rw city: State: Business Name: C4STeM A if gn r£ri1 S ]tic Zip: Phone: Y&P'10jig t� ,9 Phone:T?a 335 323a Fag: 77A 3.95. 1268 6. Value of Construction: $ OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is corrt and that all work will be done in compliance with all applicable laws regulating co ctio and zo Cy-T;S SgmrAoNS PRINT OWNER OR CONTRACTOR NAME SIGNATURE OF OWNER OR CONTRACTOR STATE OF FLORIDA, COUNTY OF ST L U r-I .a ACKNOWLEDGED BEFORE ME THIS �_ DAY OF A/ 20 / . BY (4&% /� S WHO IS PERSONALLY KNOWN TOME V1 OR WHO HAS PRODUCED OHRIGTINE R ENGUSH AS IDCATION. # MY COMMISSION 1 EE 859284 1�7 "A / XPIRES: April 4, 2017 sr. "ts TlwBudgelNoaryEieMces SIGNATURE OF NOTARY 9 TYPE OR PRINT NAME OF NOTARY "oFk�6 CONMSSIONNUMBER NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR DWROVEMENTS--TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -SEAT REPLACEMENT WITS CONTRACT UNDER S7500.00 Revised 0426/2010 AHRI Certified Reference Number: 4699990 Date: 1/9/2014 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: GSX130241D* Indoor Unit Model Number: AWUF24XX16B* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONIN Series name: Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 23000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 IEER Rating (Cooling): * Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air -Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2013 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130337586423449270 Des ignStar Load Calculation Results are intended for usewith Rheern heating and cooling systems The Nlf,,w DeTmo oofWonll SHR .75 ........... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ........... ... . ... .... . . . . . .. . . ... .. . . . . . . . . . . . . . . . . . . . . . . Nurnberof residents 4 .......... ............ Ceiling height 8 Wail U-value j R-value 0.091 11 ........ ....... ... . ... ....... . . ............ ....... ... ... .................................................. Floor U-value R-value 0.2 15 Ceiling U-value 1 R-value 19 Window U-value . 0.5 .......... .................. - .................... . ... .................. .................... ........................... ........ . . ............... ........... ......... Window SHGF 0.85 Moisture grains 64 .Duct loss % 10 Duct gain % 10 'UiF Outdoor g o HeatinColing ............... ....... .. .... ........... ... ..... ....... ........... . ........... - - - ----- D ........... . . ............ .......... N .......... .................... ........... . Relative .'humidity .50%:: ............. . ..... ........................ ............... ....... .......... .......... ............... Moisture difference ME Indoor Heating Cooling .... ...... .......... ................ ........................... . ... ........... - indoor temperature (OF) 70 75 ................. . ..... ....... ......... .. .............. .... ................... ....... .......... .................................................... ........ ....... ; .. ........ ............... .................. ............... .............. Design temperature difference('F) 23 15 Area Btuh % of load iiVall 1949 17.6 Floor 3050 27.6 _.........._.........._................................................................... _..... .......... Ceiling ................................ ._ 1284 ....... _......... ......................... ... 11.6 Windows 1116 10.1 I nfi ftrati on 2643 23.9 System Efficiency Loss 1004 9'.1 Total; 11044. Heating Loads 1.1,044 BTUIhr Floor y LOSS ows Ceiling Wall 1271 6.4 Windows 5990 30.2 Latent infiltration -3409 17.2 irifiernal, 2400 12. 0 de y�r ate EDk o� ur Diversi �b m� aa... _ , AED Graph 10000 7500 o s000 2500 orv.... _ ........ Sam Siam loam llam 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8pm — Hourly Loads — Average System equipment selection will be made using the following derived values. Glass (E) 34 sq. ft. Glass (S) 0 sq: ft.- Glass (N) 0 sq. ft. Glass (W)> 63 'scl. ft. Summer Outdoor 90°F .............. Summer Wet Bulb Summer Indoor 75°F ..... .............. ................................................................,_........,........_..,..._.........._........................_..........................._..............._..................,_........._................................................................._..........,.........._............................ Summer Design Grains 50°1Q Winter Outdoor 47°F Winter Indoor 70OF Sensible Cooling 15,526 Btuh Latent Cooling 4,323 Btuh Required Cooling Airflow 706 CFM Sensible Heating 11,044 Btuh Required Heating Airflow 143 CFM All calculations are based upon approved hvac industry standards and procedures, and comply with all local, state and federal code requirements. All computed results are Estimates. Product provided by Energy Design Systems and idea Tree