Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: FEES DUE: RECEIPT #: Permit #: Planning & Development Services Department p r Building & Code Regulation Division S Cyr g ,d u 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 4Cj6 r �� VMS, Tel. 772-462-1553 � APPLICATION FOR ROOF PERMITSEE 1. Location/Site Address: . 1,,, U)eo � W 1q VEVERJE SIDE FOR INSTRU T1-;Ve_ 2. Parcel ID Number: Office Use Only I Section Townshi Range Map Page Zoning Land Use Initials 3. Description of Projector Work Activ''i11tyy����1(� �� �� tnQW �EQnQ� 4. Total Roof Area (square feet): ZLI M 5. Roof Pitch: tD! 12- 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [v"' Other ' alproduct Approval required for all types of Roofing Material (2 Sets) ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required 7. Owner Information 8. Name: I Address: ,JJpt4,f,11 1,- ►)� City: YZIC State: L• Zip: f' Phone: 2bn 9. Value of Construction: $ 1 /1 I&.d0 Contractor Information FL Reg/Cert County Cerro Business Na Phone: "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all oft info ation contained in this application is correct and that all work will be done in compliance info . I applicable laws regulating construction and zoning. IIANN e Q ALIFIERS/OWNERS NAME SIGNATUR F QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF XS ACKNOWLEDGED BEFORE ME THIS q, DAY OF 20_d, BY WHO IS 6kSqNALLY O N TO ME OR HASP DUCED AS IDENTIFICATION • �._ NOTARY PUBLIC -STATE OF FLORIDA " Karen S. Nielsen I AT OF NOTA Y TYPE OR PRIN AME OF NOTARY Commission. #DD1000358 COMMISSION NUMBER QM r'••.,,,. Expires: JUNE 12, 2014 BONDED nMU ATLANTIC BONDING CO., INC, NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 v 2014-01-13 2/7 ray 1. Location/Site Address: 2. Parcel ID Number: Planning & Development Services Department Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel, 772-462-1553 APPLICATION FOP. ROOF PERMIT l ,-,n / SEE RE1gR4E S10E FOR INSTRLJ0%QNS , 0 Office Use I Only Section Townshi Range I Map Page I Zkirir.. I La Use I Ini 'nls 3. Description of Projector Work Activity;_ I �,1AY• (J k-.F (•5 ilq 1 )_&F_' ,Unt \\ 4. Total Roof Area (square feet): :924 M 5. Roof Pitch: t 0 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete hoof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [v' Other 'mn dproduct Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: FL Reg/Cent #: „(41 41 2 6.9 1 Address: 61iy i County Cert #: City: A416 State: ` L Business Name: ✓ %!7 Zip: Phone: 26901,2206 Phone: - 0 9. Value of Construction: $ "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval, CONTRACTOR/OWNER'S ArI iDAVIT: I eeetify 11111111101 hatalI01 in1 01it1 1 tion Contained in this application is correct and that all work will bo don, in complinn,e. ithpfl applicable laws regulating construction and zoning. P1tIN1/0'VTkIJFIFRS1OWNERSNAME SICNATURKOFQUALIFIF,R/OWNER STATE OF FLORIDA, COUNTY Olt ACKNOWLEDGED BEIVORE ME THIS DAY OF WHO IS _PM AS NAL4Y cNO N _TO ME OR HAS P. i AT O NOTA Y TYPE C COMMISSION NUMBZR 20—d, BY AS IDENTIFICATION NOTARY PUBLIC -STATE OF FLORIDA d5ld ... Karen S. Nielsen 40TARY 40 _Commission #DD1000358 =.•�JExpires: JUKE 12, 2014 DONOt nTllliVAT! ANf1C301=9CO.,Ir1R NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RMULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR [.ENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE, OF COMMENCEMENT. Revived 4/26/2010 2014-01-13 17:08 j . a. tay,!-^r roofing 772 468 8397 ��'� P 3/7 1Vt/VIt71911JIWi01 - V6VV1r10 VVYII%yp I IIRI/Jlwww,l/PJ1 ?I/OJIW III N.QDIl IIII bIrM�,GYJNVV IVV lwUvvw PROPERTY RECORD CARD .Ittt'qurlul,• vl }'gull'; liernrd: I of 1-'•ePrev NtNI'• SIM.rlsstnwt I'a%vs E%rmpllnn-, I'1•rnuh lliam Phut Propoi,v (drntllicwlion Wc1i: Site Address; 2459 SWEETWATLR DR Parcellt); 2433-Sal-0016-000.6 SoVI'own/Runge; 33 :35S :40E Account 4: 33120 Map ID: 24/33N Use Typc: SF Res %oning: RS-2 City/Cnty; Saint Lucie County f)wllcl'sIrIP I.vgH Dmeripllml Owner: Jacqueline M Young SWEETWATER S/D LOT 14 (0,53 AC) (OR 1410-847) Addrt-rs: 2459 Sweetwater Dr Fort Pierce FL 34981.5112 Sales Ial'I1rurllriolr 2013 1 tdlll Lund u111I rtnilllill; Dale Pried Code Dccd Book/Pugtr 2013 Finul; 124000 Land Voluw 56500 Acre:; O.S3 6/29/2001 126000 00 WD I410 / 0847 Assessed; 122696 Building Vuluc; 67500 $/1/1988 110000 00 CV 0$8710442 Ag.Credit: 0 I+Inlshcd Arco; 1740 SgFt Exempt: 50000 'ruxnbic; 72696 'faxes; I653.69 BUILDING INFOICNIA M:.Irrior I-0i111yeN Yicw: Roolcovet: SD - Dim Shingle ItoolStruct: GA - Gable Ext'I'ypc; HC- - HC- Ywrlllt: 1986 Pnimc; - Gradc: C- - C- 01Y01: 1986 Printewull: CB - Ccdur Bd/Btn Storyl•Ight: 0020.2 Story Nu,lJnits; 1 SCCW4111: WS - Wood/Sheath Inlrrillr tyyUlU'c} BedRooms: 3 Electric: MX - MAXIMUM PrrnlntwalL DW - Drywutl Fulllluth; 2 Hcat'I'ypc: FHA - FrcdHotAir Avgl-lt/[-'I: IP2Bath: 0 HeatFuel' ELEC - Electric Prm, Slorx CU - Carpet °/IAA/C: 100 %Floated: I00 %Sprinkled: 0 3perlal I•raturc5 arid Yard Ilctwr Laud Intornrlltiun Type Y/S Qty. Units Qua[. Cond. Yrl31t, No. Usc •Type 'rypc Mcmure Dcpth DWC - Driv-Concrct Y 1 720 AV AV 1996 1 0100-SF Res 212 -Front Ft 120 191.5 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED Page 1 of 1 2014-03-03 16:08 j.a.tayI r-M ing 772 468 8397 7724626443 P 1/1 4— Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-46Z-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit #_L I.Wvilt licensed as n)Contractor*/ ngineer/Architect (Please rint name & circle license type) *FS4 spector *General, Building, Residential or Roofing Contractor or any Individual certlfled under 468 FS, to make such an Inspection. On or about I did personally inspect the roof deck nailing (Date) work at. a�2 - Q P,=L—. (Job site a dress) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on $53.844 F.S.) Signature and Seal 5 License # STATE OF FLORID COUNTY OF Swor'n� nd subscri4 d before me this d of _ 20j by �tC�f �� u�(•I t Who Is pe onally known to me or who has produced as Identification. Notary Pu of Flori Signature o o ary: Commission Number: (Seal) En 01/19/2011 NOTARY PUi3LIC-STATE 4P FLgxipA Karen 5, Nielsen" " °CommissiO14DDIP. M ya,,,,,„••Expires: JUNE 0, 2p14 BOND= TMW ATLANTIC 1SONMd CQ ulc' . JOSEPH E. SMITH, 77RK OF THE CIRCUIT COURT - SAI LUCIE COUNTY FILE # 3915160 C�� `OOK 3595 PAGE 1097, Recorder-,1/14/2014 at 10:24 yf.13-11-ZU 14:0 J.e.taytor r00Ting (fC 400 Oa7r IIc-roi-ww r cic NOTICE OF COADIENCEM ENT TO BE COMPLETED WHEN CONMUCTION VALUE )aI (C DS �D PERMIT s>et __. ..TAX FOLIO #: L - �¢ Stm of Florlds. County of the w4wolpled haeby dives nolica that hmprout+ wdvAll be meat to oertele reeh prnpaty, and In .'>=Idinpe vMh OWpW 71y, Fbllds statutes, oe rdlass4 irdpm*W b p Wded In thh notice of Canstronca nerd. 1. LEGAL DESCRIPTION OF PROPERTY (AND STREET ADDRESS 1F AVAILABLE): D. b"3 Jl�' • �X 0-g�� • Z. GENERAL DESCRIPTION OF IMPROVEMENT: W200F 3. SOWNER INFO_ TION or ®LESS E INFORMATION (If Lisa contracted for the improvement) a. Name: — Addnessr b. Interest (n property: c. Name and address Of fee simple We holder (f other then ownef): N/ A 4. CONTRACTOR: a. Name: J. A. TAYLOR ROOFING, INC. Addrm: 3OZ MELTON DRIVE. FORT PIERCE. FL.34M b. Phone number. 7714664040 g, SURETY COMPANY (IF Applicable, a copy of the payment toad is attached): a. Name & Address: NIA b. Phone number, Bond amount g, LENDERIMORTGACE COMPANY: a. Name & Address NIA b. Phone number PERSONS WITHIN THE STATE OF naRWA DENGNAT90 BY OWNER UPON WHOM NOTICES OR OTHER DOCUMENTS MAYBE SERVED AS PROVIDED BY SECTION 71113 (1) (s) 7.. FLORIDA STATtnr : a. Nam & Address: NIA b. Phone number, fax number. g, IN ADDITION TO HIMSELF OR HERSELF, a. OwnerdoslpnatsaN/A of to Iscelve s copy cf this lienof e nouns us provided in seafion 713.13(1)(b), Florida stabs, b, Phone number, g. EXPIRATION DATE OF NOTICE OF COMMENCEMEn: (THE EXPIRATION DATE IS ONE (1) YEAR FROM THE DATE OF RECORDING UNLESS A DIFFERENT DATE 15 SPECIFIED). A NOTICE O►COMMENCICRIM MUST es. RZCDMED AND POSTED ON THUODUM DEFORE VK9 FIRBT INSF=NK W YOU INf WD TO OBTAIN FINANCING,COMWLT WRn YOUR LUMCROEAN ATTORNEY UPORE COMM>I 0M NOWOR RECORDING YOUR NOTICE ORCOMMENCEIiPNT. UNDER P9NALTIfi9 OF PFR.WM-C;MARETHAT I HAVE READ THE FOREGOING AND THAT THE FACTS IN fT ARE TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF (BECF —KM FLORIDA STATUTES THE FOREGOI r STRUM NT A XNOWLEDGED BEFORE ME THIS DAY OF , 20, eY:. ) f� Q.ILEU _ Da & NAME OF PER90NSTYPEOFAUTHORIIY NAME OF PARTY ON BEHALF OF WHOM INSTRUMENT WAS MMUTED LLYIOVOWN-OR WPRODUCEDIDENTIFICATION TYPE OFIDENTIFICATION PAODUCED — ------ .....-..- l; DANAAEVANS OTARYSIGNATURE / NOTARYPRINTEDNAME / NOTARY SEAL = My COMMISSION # OD978M EXPIRES June 12.2014 (407) 30"153 FwMe niu.com STATE OF FLORIDA ST. L CIE UNTY THI 11 0 CERT FY TjAT IF 6 A T1)ORRIUGEI D COR T Py OF THE Date- Property Appraiser - St. Lucie County, FL .Jacqueline Vl Young Record: 1 of I Property Identification Site Address: 2459 SWEETWATER DR Sec/Town/Range: 33 :35S :40E Map ID: 24/33N Zoning: RS-2 Ownership and Mailing Owner: Address: Sales Information Date Price 6/29/2001 126000 5/1/1988 110000 Jacqueline M Young 2459 Sweetwater Dr Fort Pierce FL 34981-5112 Code Deed 00 WD 00 CV http://www.pa;>' --i g/paslc/prc.asp?prclid=243360100160006 PROPERTY RECORD CARD «Prev Next» Spec.Assmnt 'faxes Exemptions Permits Home Print CO ParceIID: 2433-601-0016-000-6 Account #: 33120 Use Type: SF Res City/Cnty: Saint Lucie County 'N Legal Description SWEETWATER S/D LOT 14 (0.53 AC) (OR 1410-847) Assessment 2013 Book/Page 2013 Final: 124000 1410 / 0847 Assessed: 122696 0587 / 0442 Ag.Credit: 0 Exempt: 50000 Taxable: 72696 T axes: 1653.69 BUILDING INF6. RMA Total land and Building Land Value: 56500 Acres: 0.53 Building Value: 67500 Finished Area: 1740 SgFt Exterior Features View: RooiCover: SD - Dim Shingle RoolStruc-t: GA - Gable ExtType: HC- - HC- YearBlt: 1986 Frame: - Grade: C- - C- EfiYrBlt: 1986 PrimeW all: CB - Cedar Bd/Btn StoryHght: 0020 - 2 Story No.Units: 1 SecWall: WS - Wood/Sheath interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmIntWall: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHt/FI: 1/2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Ward Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Use Type Type Measure Depth DWC — Driv-Concret Y 1 720 AV AV 1986 1 0100-SF Res 212 -Front Ft 120 191.5 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED Page 1 of 1 i A.%t L Mm_ / Yv u N (7) Treasure Harvey <)ehnen C dast ' Profes . I Engineer #32831 B uilding Architect #AR0009471 E ngineers, Certified General Contractor #CGCO24776 Inc. Contractor _1 - A • Y CG Owner 0 u N 61 Job Address Z 4 S ✓E�TWI� �t� v�•. METAL ROOFING NEW ROOF RE -ROOF X REPAIR AREA 3 `- 04 METAL ROOF PLAN 7205 Elyse Cird P S L Florida 34;;sz-o212 PHONE(772) 466-5509 FAX(772)489-3035 E-MAILL•h koeh nen @tcbeweb.com Date 1 Z110 � 1 3 IBM���w����n 0�2'-,459 Sweetwater: 3:0- t ■■■■,■■,■.� ASCE 7-10 & FBC 2010 ENCLOSED BLDG x SEMI ENCLOSED BLDG OPEN PART 2 LOW RISE C&C SIMPLIFIED RISK CAT 2/V = l & O /EXPOSU RE__! / = f •6 JKzt =1.0/h �� (P /12 PITCH ROOF SYSTEM_ R55f.M. 'A I +dfrA _I^ L 1 ¢SZO. 1 i ZONE 1 P @ @ h=30 = X = PSF x 0.6 = - Y 5.3 ZONE 2P@ @ h=30 = X - PSFx0.6=-� -�I�' a= V ZONE 3 P @ @ h=30 = X - PSF x 0.6 = to;' a = JOY MAX DESIGN PRESSURE PER NOA-40.2.5@ t(o"r DEC14T 1'PE WQ7 THICKNESS �32` j� ►tJ � rn BAS�ESHHEET """"NO. OF PLIES _FAS '1�E$gg�MOPACING ,4-&W Z r�a,*L;Rt ` FIOLP PLY SHEET NO. OF PLIES FASTENER TYPE - SPACINIT TOP PLY NO. OF PLIES INSULATION BASE LAYER TYPE FASTENER TYPE - SPACING SIZE - TYPE OF FASTENERS: SPACING FIELD PERIMETER - CORNERS -- INSULATION TOP LAYER TYPE SIZE TYPE OF FASTENERS AL rj U160jVsC4LW44 . V I'VIA Sa0ft. iNk tAJ PVSr g(2- DRIP EDGE SIZE - V x 3" DRIP MATERIAL Z& Ak dt-I FLASHING MATERIAL 2-& FASTENER SPACING FOR METAL ROOF PANELS: FIELD ` A'� t_hP 5 L tJ i:� s F �AtJ Ei. It!d�• PERIMETER � CORNER _� ZW k I T reasure Harvey E. Koehnen C oast Professional Engineer #32831 6 u i Id i ng Architect #AR0009471 E ngineers, Certified General Contractor #CGCO24776 Inc. `these tables Are For Roof Coverings Roof coverings Installed on Buildings with a Mean Roof Helght of Nor Less Located in Exposures B, C or D 'fable R301.2 [2]__0E-� A5cl 7-tt) COI+IPONENTS AND CLADDING WORST CASE DESIGN PRESSURE [PSF]. 16=Exxp::B 160 Exp C 160 Exp C 160 Exp D 160 Exp D (One story (Two story*) (One story) (Two story Roof > 0 to 7 degrees Zone 1 -27.6 -33.4 -38.7 -40.6 -45.9 7degrees = 11/2 /12 pitch Zone 2 -46.4 -56.2 -65.0 -68.3 -77.1 Zone 3 -69.8 -84.5 -97.7 -102.7 -115.9 oof > 7 to 27 degrees -30.7 -35.5 =ne-2 - 53.4 -61.8 -78.8 - 91.2 Roof > 27 to 45 degrees Zone 1 - 27.8 -33.7 -40.0 4t5 degrees = 12/12 pitch Zone 2 - 32.4 -39.3 -45.4 Zone 3 - 32.4 -39.3 -45.4 Roof > 0 to 7 degrees Zone 1 7degrees = 11/2 /12 pitch Zone 2 Zone 3 = Roof >.7 to 27 degrees Zone 1 -'. 27=degrees = 6/12 pitch Zone 2 Zone 3 -37.2 - 42 -64.9 - 73.3 - 95.7 - 108.,1 -40.1 -46r2 -47.7 -53.8 Q �I - 47.7 -53.8 N 1 150 Exp l3 150 Exp C 150 Exp C 150 Exp D 150 Ei p D (one story'") ( two story*) (one story*) ( two story) -24.3 -29.6 -34.1 -35.8 -40.4 -40.8 -49A -57.2 -60.0 -67.8 -61.4 -74.3 -86.0 -90.3 -102.0 -22.2 - 26.9 - 31.1 -32.7 - 36.9 -38.7 - 46.9 - 54.2 -56.9 - 64.3 -57,3 - 69.4 - 80.3 -84.3 - 95.2 Roof > 27 to 45 degrees Zone 1 - 24.8 45 degrees = 12/12 pitch Zone 2 - 28.4 Zone 3 - 28.4 ' 29.6 -34.1 -35.8 -40.4 -34.4 -39.8 -41.8 -47.2 -34.4 -39.8 -41.8 -47.2 One story* = one story building with a maximum mean roof height of 15 feet Two story* = two story building with a maximum mean roof height of 30 feet If allowed by the Miami Dade N.O.A or Florida Product Approval any system that does not meet the mihimum components and cladding pressures for the area that the building is located per this form may require a Florida licensed engineer to revise the fastener spacing T C B E, Inc. 7205 Elyse Circle PHONE (772) 466-5509 Port Saint Lucie FAX (772) 489-3035 Florida 34952-8212 E-MAIL hkoehnen@tcbeweb.com WEB SITE http://www.tcbeweb.com Florida Building Code Online r , Page 1 of 2 FLORIDA 69PA;rh%Nr0P Susiness ► 1 1' 1 1 Florida Departments BCIS Home Log In ? User Registration I Hot Topics { Submit Surcharge I Stats & Facts i Publications FBC Staff BCIS Site Map Links I Search it Busines/ Professi dal 6:1. Product Approval USER: Public User Regulation Product Aooroval Menu > Product or Application Search > Application List > Application Detail FL # FL14520-R1 Application Type Revision Code Version 2010 Application Status Approved Comments Archived ❑ Product Manufacturer I A TAYLOR ROOFING Address/Phone/Email 302 Melton Drive FT PIERCE, FL 34982 (772) 466-4040 flvalidation@yahoo.com Authorized Signature Kyle Taylor flvalidation@yahoo.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed, A Florida Professional Engineer 2 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Charles L THO MAS the Evaluation Report ^% Florida License PE-29439 \ Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/11/2021 Validated By Locke Bowden Wj Validation Checklist - Hardcopy Received Certificate of Independence FL14520 R1 COI Certificate of Independence FPA.odf Referenced Standard and Year (of Standard) Standard Year TAS 125 2003 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 11/07/2011 http://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGEVXQwtDquxTVBj*riRcYs... 12/9/2013 Florida Building Code Online Page 2 of 2 Date Validated Date Pending FBC Approval Date Approved Summary of Products 11/07/2011 11/10/2011 12/06/2011 FL # Model, Number or Name Description 14520.1 5 V CRIMP 26GA METAL ROOFING PANEL Limits of Use Installation Instructions Approved for use in HVHZ: No FL14520 RI II 5V Crimp Evaluation Approved for use outside HVHZ: Yes Report Details Rev.odf Impact Resistant: N/A Verified By: PRI Construction Materials Technologies, LLC Design Pressure: +N/A/-129.25 Created by Independent Third Party: Yes Other: The required design wind loads shall be determined Evaluation Reports for each project per the Florida Building Code. The maximum FL14520 R1 AE 5V Crimp Evaluation Report Rev.odf Created by Independent Third Party: Yes fastener/clip spacing listed herein shall not be exceeded. This product is not evaluated for use in the High Velocity Hurricane Zone. Back Next Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Convriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 0616901 0 C'edil: C�rd http://www.floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDquxTVBjnRcYs... 12/9/2013 J.A. Taylor Roofing Inc: Evaluation. Report for 26 ga. 6V Crimp Metal Roof Assembly FL# 14520-111 Evaluation ' Report Report for: J.A. Taylor Roofing Inc. Date: November 3, 2011 302 Melton Drive Fort Pierce, FL 34982 Building Code: 2010 Florida Building Code Compliance Method: Rule 9N-3.005(1)(d) Sestion(s): 1504.3.2 Category: Roofing Project No.: FAE-001-01-01 Sub -Category: Metal Roofing Scope: Product Category. Roofing `V. Sub -Category: Metal Roofing L Compliance: The 26 ga. 5V Crimp Metal Roof Assembly described herein has demonstrated compliance . with Beetion 1504.3.2 of the 2010 Florida Building Code. v References: Test Application Standard (TAS) 125-03 Standard Requirements for Metal � Roofing Systems, Section 8 testing pursuant to Hurricane Test Laboratory, LLC (FBC Organization ID No. TST1527) report no. 0224-0501-06, dated October 31, 2006. Report addendum for report no. 0224-0501-06 (Specimen #1, 2, U) issued by Hurricane Test Laboratory, LLC (FBC Organization ID No. TST1527), dated September 28, 2011 Drawings # '26" 5V 24" Coverage' issued by Hurricane Test Laboratory, LLC (FBCOrganization ID No. TST1527), dated September20, 2011. Engineering Analysis by PRI Construction Materials Technologies (FBC Organization No.TST5878), dated April 19, 2011. Product Description: 5V Crimp panel, minimum 26 ga. corrosion resistant steel (Grade 80), 26" panel (2N' maximum coverage), W ribs; material shall comply with 2010 Florida Building Code, Section 1507.4.3. Minimum #9-15 HWH corrosion resistant fasteners with sealing washers designed for metal to wood connections of sufficient length to penetrate 5/16" through the sheathing. Material shall comply with 2010 Florida Building Code, Section 1507.4.4. Limitations: Limitations and Conditions of Use include the following. This evaluation does not include use of the product within the High -Velocity Hurricane Zone (HVHZ). • Fire Classification is not within scope of this Evaluation Report; refer to a current Approved Roofing Materials Directory for fire ratings of this product. Page 1 of 3 J.A. Taylor Roofing Inc. Evaluation Report for 26 ga. 5V Crimp Metal Roof Assembly FL# 14520-111 • The product shall be installed in accordance with the Manufacturer's instructions and the Roof Assemblies section herein. • Modifications of the products as evaluated herein are beyond the scope of this evaluation. • All products listed herein shall have a quality assurance audit in accordance with F.A.C. Rule 913-72. Roof Assemblies: Assembly No. 1 Max Design Pressure: -69.25 Slope: 2:12 or greater d neck: ✓Minimum 15/32" plywood or wood plank Deck Attachment: In accordance with the applicable Code. In no case less than minimum 8d x 2" annular ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (minimum 15132") the above attachment method must be in addition to existing attachment. Deck attachment to be designed by others. Underlayment. Minimum ASTM D 226, Type II (No. 30) in accordance with Section 1507.2.E of the 2010 Florida @uilding Code or any Approved underlayment having current Florida Statewide or Local Product Approval. 5V Crimp Panels: Installed in accordance with Manufacturer's installation instructions. ,Minimum #9-15 corrosion resistant fasteners with sealing washers designed for metal to wood connections of sufficient length to penetrate 5/16" through the sheathing installed 16" o.c. along the crown of the rib in the center of panel and along the lap (See Drawings). Max Des)an Pressure:-129.25 Slope: 2:12 or greater Deck: Minimum 1 2" plywood or wood pi nk DeckAtfachment: In ace dance with the applicable Co . n no case less tha inimum $d x 2" annular ring anlc nails spaced 6" In reroofing, where the deck ' less than T9�2" thick ( inimum 15132") the above a chment method ust be in ddition to existing attac ent. Deck attachm t to bed signed by others. Underlaym t� Minimu ASTM D 22 , Type II (No. 30) in accordan with Secti n 1507.2. of the 2010 Florida Building Code or any Ap oVed derlayment having current Florida Page 2 of 3 J.A. Taylor Roofing Inc. Evaluation Report for 26 ga. 5V Crimp Metal Roof Assembly FL# 14520-R1 Drawings: ewlke or Local Pr9duct Approval. 5V imp Panels: Installed in cco ante with nufacturer's inst llation - - - instructions: Minimum- #9-1 corrosion-- sistant- fasteners s sling washers de corrosion -- for metal to wood ections f sufficient length pen to 5/16" thro the sheathin installed 8" o.c. al he crown of t rib in the center f panel and al he IaR (fee 5-V PANEL PROFILE 24" Coverage .5—V FASTENER DETAIL Quality Assurance: Keystone Certifications. (FBC Organization No. QUA1824) Evaluator:: Charles L. Thomas, P.E; A Florida Registered Profes9igb- f Engineer s ; PE No.: 29439 -; : �? �a CV FBC Organization No.: ANE9008 ; 14609 Dixie Hwy, Huds6,n ,FL'°,346V7 (';�v Date: 1/j3/,-24�1/`( Page 3 of 3