HomeMy WebLinkAboutSUBMITTED PAPERSDate: Fee Due: Recei t# Permit #JU
Planning & Development Services
Building & Code Regulations Division 2300 Virginia Ave. `
Fort Pierce, FL 34982 1
(772)462-1553
SPECIALTY PERMIT APPLICATION
❑ Electrical ❑ Plumbing ® HVAC ❑ Fence SCByNlJ
❑ Shed ❑ Demolition ❑ Gas ❑ Siding St. t Qcie
y
Seepage 2 for instructions and additional paperwork required for specialty permits
1. Location/Site Address: 5604 Killarney Avenue
2. Parcel ID Number: 1301-613-0392-000-3
Office Use
Only
Section
Township
Range
Map Page
oning
Land Use
Initia
3. Complete Description of Project or Work: Replacement of existing ductwork.
4. Owners Information
Name: Tara and Willie Smith
5. Contractors Information
FL Reg/Cert #:
Address: 5604 Killarney Avenue County Cert#:
City: Fort Pierce
Zip: 34951
A 113gb3
— A-5- 1(?q
State: FL Business Name: Air Experts
Phone: one: 772-828-0702 Fax:
6. Value of Construction: $ 750.00
(1
1
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct anthat all work will be done in
compliance with all applicable laws regulati onstruction and zoning.
Ryan O'Neill r -L)A,4 0 � &-
PRINT OWNER OR CONTRACTOR NAME SIGNAT OF OWNER OR CONTRACTOR
STATE OF FLORIDA, COUNTY OF 1Saint Lucie
ACKNOWLEDGED BEFORE ME THIS r DAY OF A.) 20 14 By p,r( I)i n e UA
WHO IS PERSONALLY KNOWN TOME x OR WHO PRODUC
AS I N FICATION.
►' GW l� g I►A ��I ZQ�!3Q QV l�E96
;;NA EUZABETH DAVISSI A E OF NOT Y TYPE OR PRINT NAME OF NOTARY MY COMMISSION ti EE177496
'I n MMISSION NUM RI ?7 i""1CQ;�.••�� EXPIRES M2rch 08, 2016
a-01S FWftNot jSeMoe.com
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWIC
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00
Revised 04/26/2010
NOTICE TO OWNER: FAILURE TO -KECORD A NOTICE OF COMMENCEMENT MAY-Ri�SULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $5,000.
INSTRUCTIONS
Please complete all information in the space provided. All information must be printed (use black or blue ink
only) or typed. This permit application is to be used only for those activities that are not otherwise included
under a primary building permit. This application may not be used for any activity that includes structural
alteration. The information to be provided with this application includes:
1. Location/Site Address
2. Parcel ID Number
3. Description of Project or Work Activity
4. Owner Information
5. Contractor Information
6. Value of Construction
Indicate the street address or general location of
property where the building activity is taking place.
Indicate the tax identification number of the
property where the building activity is taking place.
Fully describe the activity to take place.
Indicate the name and address of the owner of the
property on which activity is taking place.
Indicate the State of Florida registration number (if
applicable), St. Lucie County contractor license
number and the name of the business doing the
work.
Indicate the total value of the work to take place.
Total cost of construction includes all current retail
material and labor costs associated with the
building/construction activity. Construction value is
used to determine the permit fee. St. Lucie County
reserves the right to question and/or modify the
indicated value of construction if it is demonstrated
that the submitted figures are not consistent with
similar types of construction.
❑ Gas
Attach 2 piping schematics with tank size, location, and BTU of each appliance
❑ Shed:
Attach 2 plot plans, 2 copies of DCA letter and plans, 2 anchor specifications
❑ Fence
Attach 2 plot plans showing location of fence height of fence and type of fence
❑ Siding
Attach 2 copies of manufactures specifications
❑ HVAC Attach 2 residential energy studies, 2 manual J calculations. 2 sets of duct layouts for
new system or full replacement
This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce,
FL 34982. All permit applications must be filled out completely before submission. No applications will be
accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772)
462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday.
NOTE: Emergency electric service change out inspections will not be performed after 3: 00 PM without
special arrangements and additional fee paid.
Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261.
J
K
1
2
3
5604 KILLARNEY AVENUE
H G
EXTERIOR DOOR SCHEDULE
WINDOW SCHEDULE
FRONT DOOR 3068
HEIGHT
WIDTH
HOUSE to PATIO 3068 A (Triple)
111"
X 63"
HOUSE to GARAGE 2868 B
73"
X 37"
C
36"
X 37"
D
36"
X 37"
E (Shower)
36"
X 26"
F
36"
X 50"
G (Double)
73"
X 38"
H (Triple)
110"
X 50"
1
31"
X 36"
J
36"
X 24"
K
36"
X 24"
D SION
M'OITyST.
. COiJNTS' BUILDING
REVIEWED FOR MPL
REVIEWED B
DATE
MUST BE KEPT ON JOB
PLANS P T
WILL BE MADE.
ORNO INSPECTION
F
E
0
C
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 5604 KILLARNEY AVENUE
Builder Name:
Street:
Permit Office:
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing
Existing (Projecte
- 9. Wall Types (1264.0 sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1264.00 ft'
b. WA
R= ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
5. Is this a worst case?
No
10. Ceiling Types (1512.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1512.00 ft2
6. Conditioned floor area above grade (ft2)
1512
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(175.0 sgfL) Description
Area
a. Sup: Attic, Ret: Attic, AH: Main
6 176
a. U-Factor: Sgl, U=1.07
175.00 1`12
SHGC: SHGC=0.50
b. U-Factor. WA
ft2
12. Cooling systems
kBtulhr Efficiency
SHGC:
a. Central Unit
34.2 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kShAr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.500
14. Hot water systems
8. Floor Types (1512.0 sgft.)
Insulation Area
a. Electric
Cap: 40 gallonsEF:
a. Slab -On -Grade Edge Insulation
R=0.0 1512.00 ft2
b. Conservation features
0.920
b. N/A
R= ft2
None
c. NIA
R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.116
Total Proposed Modified Loads: 28.16
PASS
Total Standard Reference Loads: 35.16
1 hereby certify that the plans and specifications covered by
Review of the plans and
SrATF
this calculation are in compliance with the Florida Energy
specifications covered by this
0J-114E
AV
Code.
calculation indicates compliance
PREPARED BY:
with the Florida Energy Code.
Before construction is completed
� �m„� `•" °„ �O
v
DATE: 1. - -
this building will be inspected for
'' a
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
COD
with the Florida Energy Code.
WE
i
OWNER/AGENT'
BUILDING OFFICIAL:
DATE: I • 3
DATE:
11/7/2013 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
5604 KILLARNEY AVENUE Bedrooms: 3
User Conditioned Area: 1512
Total Stories: 1
1 Worst Case: No
Rotate Angie: 0
Cross Ventilation:
Whole House Fan:
Single-family
Exsting (Projected)
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
ST. LUCIE COUNTY
FT. PIERCE,
FL,
CLIMATE
/
v Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1512 12096
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1512 12096 Yes 4
3
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 145 ft 0
1512 ft2
0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip Composition shingles 1638 ftz 0 ft2 Medium
0.96
No 0.9
No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300
1512 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
Under Attic (Vented)
Main 30 1512 ft2
0.11
Wood
11/7/2013 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
WALLS
Adjacent
Space
Cavity Width
Ft In Ft
Height
In Aran
Sheathing Framing , Solar
R_-Vahle Eraction Absor-Grade%
Below
1
N
Exterior Concrete Block - Ext Insul Main
4.09999 37 8
296.0 ft'
0
0 0.75
0
2
E
Exterior Concrete Block - Ext Insul Main
4.09999 42 8
336.0 ft'
0
0 0.75
0
3
S
Exterior Concrete Block - Ext Insul Main
4.09999 37 8
296.0 fP
0
0 0.75
0
4
W
Exterior Concrete Block - Ext Insul Main
4.09999 42 8
336.0 ft'
0
0 0.75
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height -
Area- -
-
-
-
-
Ft
In
Ft In
1
S
Insulated Main
None
.46 3
6 8
20 ft'
2
N
Insulated Main
None
.46 3
6 8
20It'
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Omt ID Frame
Panes NFRC
U-Factor SHGC
Area Depth
Separation
Int Shade
Screening
1
N 1 Metal
Single (Tinted) Yes
1.07 0.5
9.0 ft' 2 It 0 in
6 ft 0 in
Drapes/blinds
None
2
N 1 Metal
Single (Tinted) Yes
1.07 0.5
36.0 ft' 2 ft 0 in
6 ft 0 in
Drapes/blinds
None
3
N 1 Metal
Single (Tinted) Yes
1.07 0.5
18.0 ft' 2 ft 0 in
6 ft 0 in
Drapes/blinds
None
4
E 2 Metal
Single (Tinted) Yes
1.07 0.5
36.0 ft' 2 It 0 in
6 It 0 in
Drapes/blinds
None
5
E 2 Metal
Single (Tinted) Yes
1.07 0.5
4.0 ft' 2 ft 0 in
6 ft 0 in
Drapes/blinds
None
6
S 3 Metal
Single (Tinted) Yes
1.07 0.5
15.0 ft' 2 It 0 in
6 It 0 in
Drapes/blinds
None
7
S 3 Metal
Single (Tinted) Yes
1.07 0.5
45.0 ft' 2 It 0 in
6 It 0 in
Drapes/blinds
None
8
W 4 Metal
Single (Tinted) Yes
1.07 0.5
12.0 ft' 2 ft 0 in
6 It 0 in
Drapes/blinds
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
198 ft2
198 ft'
376 It
8 ft
11
INFILTRATION
#
Scope
Method
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Best Guess
.0005
1983 108.86 204.73 .365
9.8363
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat
None
COP: 1
27 kBtu/hr
1
sys#1
1117/2013 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Page 3 of 5
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit
None
SEER: 16
34.2 kBtu/hr 1026 cfm
0.75
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None
Garage
0.92 40 gal
60 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC— - -
Collector
Storage
Cert
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft'
DUCTS
V
— Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
#
Location R Value Area
Location
Area Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Cool
1
Attic
6 178 ftz
Attic
20 ft2 Default Leakage
Main
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[ ]
Heatinf
Jan [[ ]] Feb
Jan [X] Feb
Mar
Mar
r , r r
[ ]r [
Ma rX Jun rl Jul
May Jun Jul
AuSeP
rl Au
rl Se
W
Oct
Oct
Nov
Nov
H
H Dec
Dec
Venting [ ]
Jan [ I Feb
Mar
[[[XXX]]] Apr [[[
]]] Ma [[ ]]] Jun Jul
l
Aug
Se
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Coofing (WEH)
AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating(WD)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating(WEH)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68,
68 68 68
68
68
68
68
66
66
11/7/2013 9:12 AM EnergyGaugeO USA - FiaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: PERMIT #:
FT. PIERCE, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT _
SECTION -
- SUMMARY OF-REQUIREMENT(S) -
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating
controls
and cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies
in Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R-2 + accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawispaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of =1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4116/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
11/7/2013 9:12 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 80
The lower the EnergyPerformance Index, the more efficient the home.
FT. PIERCE, FL,
1. New construction or existing
Ebsting (Projecte
9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1264.00 1`12
b. N/A
R=
ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
3
d. N/A
R=
ft2
5. Is this a worst case?
No
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
1512.00 ft2
6. Conditioned floor area (ft)
1512
b. N/A
R=
ft2
7. Windows" Description
Area
. N/Aucts
R
a. U-Factor: Sgl, U=1.07
175.00 ft2
11.
a. Sup: Attic, Ret: Attic, AH: Main
R ft2
6 178
SHGC: SHGC=0.50
b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems
kBhdhr
Efficiency
c. U-Factor: NIA
ft2
a. Central Unit
342
SEER:16.00
SHGC:
d. U-Factor: NIA
ft2
SHGC:
13. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
2.000 ft.
a. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average SHGC:
0.500
8. Floor Types
Insulation
Area
14. Hot water systems
a. Slab -On -Grade Edge Insulation
R=0.0
1512.00 ft2
a. Electric
Cap: 40 gallons
b. N/A
R=
ft2
EF: 0.92
c. N/A
R=
b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
114E Sr
+ �' cC
♦,1,C0
D WE C
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
*"Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
a
5604 KILLARNEY AVENUE
H G
5604 KILLARNEY AVENUE
H G
10x 0
F
SCREENED PORCH MASTER MASTER BEDROOM
I5' X 20' CL 13' X 16'
GREAT ROO
15'51,X18'11
-
1 �.s
1
J
- AHU
` LOS TER BATHROOM
10' x 4' X y4X4
E
1 z
10 q LINEN CLOSET
J
` UIILITYAREA
~KITCHEN —I GUESI'RATH BEDROOMa2
D
luji(o�f 13' 1" X 10' 4" roNp0 6'X 5' 10' X 11'
Kr��
K�c lOk� ".l�PytC
3 �r�I 1 ��CL
COAT r�XI� �2SC�wi
GARAGE CLOSETY Q „f 7
11' X 18' ff l35
C
BEDR00
1515"x10'
15��= CL
DINING ROOM
13'1"X9'8"
1 �
A B
EXTERIOR DOOR SCHEDULE
WINDOW SCHEDULE
1 FRONT DOOR 3068
HEIGHT
WIDTH
2 HOUSE to PATIO 3068
A (Triple)
111"
X
63"
3 HOUSE to GARAGE 2868
B
73"
X
37"
C
36"
x
37"
D
36"
X
37"
E (Shower)
36"
X
26"
F
36"
X
50"
G (Double)
73"
x
38"
H (Triple)
110"
x
50"
1
31"
x
36"
1
36"
X
24"
K
36"
x
24"