HomeMy WebLinkAboutSUBMITTED PAPERSPermit #
Date: Receipt# -
Planning & Development Services SCA
Nv
Building & Code Regulations Division St Sy 'SL
2300 Virginia Ave.
Fort Pierce, FL 34982 UC�� C
(772)462-1553
SPECIALTY PERMIT APPLICATION
_❑ Electrical - ❑ Plumbing - ®- HVAC - ❑ Fence- - - - -
❑ Shed ❑ Demolition ❑ Gas ❑ Sidingr�
Seepage 2 for instructions and additional paperwork required for specialty permits v
l
1. Location/Site Address: 7905 Fort Walton Avenue
2. Parcel ID Number: 1301-606-0105-000-3
Township Range Map Page ning Land Use Initials
Office Use Section j
Only
3. Complete Description of Project or Work: Replacement of existing ductwork.
4. Owners Information
Name: Fallon Tuthill
Address: 7905 Fort Walton Avenue
City: Fort Pierce
Zip: 34951
5. Contractors Information
FL Reg/Cert #: LA 153q (p?�,
County Cert#: ol V
�—[
State: y2jPFLL Business Name:
Phone: c� O`.J"shone: 772-828-0702
6. Value of Construction: $ 750.00
Air Experts
Fax:
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in
compliance with all applicable laws regulZconstruction and zoning.
Ryan O'Neill
PRINT OWNER OR CONTRACTOR NAME SIGNATU3E OF OWNER OR C NTRACTOR
STATE OF FLORIDA, COUNTY OFSaJ}i��jnt Lucie ,.
I^i"�'
ACKNOWLEDGED BEFORE ME THIS
f�DAY OF 20 14 , BY 7?y art
WHO IS PERSONALLY KNOWN TO ME x OR WHO PRODUC
AS I E TIFICATION. e
t 641 n-2 Labhh it ly ' „ K�J§XJNA EUZA8.ETH DAVIS
N URE OF NO Y TYPE OR PRINT NAME OF NOTARY MY COMMISSION # EE177466
• AEI
OMMISSION NUMBER EXPIRES March 08, 2016 �
'f'R �.F'
407) 30.0153 FFor1dallotaWSwv1w=m
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00
Revised 04/26/2010
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY KESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $5,000.
INSTRUCTIONS
Please complete all information in the space provided. All information must be printed (use black or blue ink
only) or typed. This permit application is to be used only for those activities that are not otherwise included
under a primary building permit. This application may not be used for any activity that includes structural
alteration. The information to be provided with this application includes:
1. Location/Site Address
2. Parcel ID Number
3. Description of Project or Work Activity
4. Owner Information
5. Contractor Information
6. Value of Construction
Indicate the street address or general location of
property where the building activity_ is taking place. -
Indicate the tax identification number of the
property where the building activity is taking place.
Fully describe the activity to take place.
Indicate the name and address of the owner of the
property on which activity is taking place.
Indicate the State of Florida registration number (if
applicable), St. Lucie County contractor license
number and the name of the business doing the
work.
Indicate the total value of the work to take place.
Total cost of construction includes all current retail
material and labor costs associated with the
building/construction activity. Construction value is
used to determine the permit fee. St. Lucie County
reserves the right to question and/or modify the
indicated value of construction if it is demonstrated
that the submitted figures are not consistent with
similar types of construction.
❑ Gas
Attach 2 piping schematics with tank size, location, and BTU of each appliance
❑ Shed:
Attach 2 plot plans, 2 copies of DCA letter and plans, 2 anchor specifications
❑ Fence
Attach 2 plot plans showing location of fence height of fence and type of fence
❑ Siding
Attach 2 copies of manufactures specifications
❑ HVAC Attach 2 residential energy studies, 2 manual J calculations. 2 sets of duct layouts for
new system or full replacement
This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce,
FL 34982. All permit applications must be filled out completely before submission. No applications will be
accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772)
462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday.
NOTE. Emergency electric service change out inspections will not be performed after 3: 00 PM without
special arrangements and additional fee paid.
Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261.
FORT WALTON AVENU' "
' G F E
will E.-
GREAT ROOM
PATIO 14 X 25
14x14'
3`
t,
H
VANITY ': CL I PANTRY
I
KITCHEN D
CL 9' 5 3/4" X 13' 8"
MASTER BEDROOM
11'4"X12'7"
MASTER BATH AHU LOCATED HERE
IN ATTIC
BREAKFAST AREA
DINING ROOM 15' X 610"
CL BATHROOM 2 12 X 7 C
BEDROOM 2 5 X 7 0
J 12 X 11 er T I TflC I'Y $*l�la. [�1G DMSIO�i
REvw,WED FOR
REVIEWED BY
DATE "
PLANS ADD PER�1 T T BE KEPT ON JOB
OR NO INSPECTION WILL BE MADE.
BEDROOM 3 LAUNDRY
K 14X11 12X5 1 A
CL
LIVING ROOM
15 X 14
2
B B3
B2
EXTERIOR DOOR SCHEDULE
GARAGE 1 FRONT DOOR 3068
20 X 19 2 HOUSE to GARAGE 2868
3 SLIDING GLASS 6068
WINDOW SCHEDULE
WIDTH HEIGHT
GARAGE DOOR 16 X 7 A 35.5" X 62.5"
Bl 25" X 62"
B2 51" X 62"
B3 25" X 62"
C 51" X 49.5"
D 35.5" X 49 3/4"
E 46.5" X 59 3/4"
F 46.5" X 59 3/4"
G 46.5" X 59 3/4"
H 51.5" X 49.5"
1 25" X 49.5"
J 51.5" X 50"
K 51.5" X 50"
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: ST. LUCIE COUNTY
Builder Name:
Street: 795 FORT WALTON AVE.
Permit Office:
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing
Existing (Projecte
9. Wall Types (1552.0 sgtQ
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1552.00 ft'
b. N/A
R= ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
2
d. N/A
R= ft2
10. Ceiling Types (1819.0 sgft.)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 1819.00 ftF
6. Conditioned floor area above grade (ft2)
1819
b. N/A
R= ft
c. N/A
R= fN
Conditioned floor area below grade (ft)
0
11. Ducts
R ft2
7. Windows(195.0 sgft.) Description
Area
a. Sup: Attic, Ret•. Attic, AH: Attic
6 363.8
a. U-Factor: Sgl, U=1.07
195.00 ft2
SHGC: SHGC=0.50
b. U-Factor: WA
ft2
12. Cooling systems
kBtulhr Efficiency
SHGC:
a. Central Unit
34.2 SEER:16.00
c. U-Factor: N/A
1`12
SHGC:
13. Heating systems
kBhdhr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.500
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1819.0 sqft.)
Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation
R=0.0 1819.00 ftZ
b. Conservation features
b. N/A
R= ft2
None
c. NIA
R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.107
Total Proposed Modified Loads: 33.03
PASS
Total Standard Reference Loads: 41.14
1 hereby certify that the plans and specifications covered by
Review of the plans and
Sr -
�-vIAE S74
this calculation are in compliance with the Florida Energy
specifications covered by this
indicates
vC
_
Code.
calculation compliance
y�.,,,''% ,•'',.��
_=.°'':•,„ ��
with the Florida Energy Code.
,rr,uf' .
PREPARED BY:
Before construction is completed
DATE: -1m2t
this building will be inspected for
compliance with Section 553.908
0
a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
CDD
with the Florida Energy Code.
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: N • f
DATE:
11/6/2013 2:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5
PROJECT
Title:
ST. LUCIE COUNTY
Bedrooms: 2
Address Type: Street Address
Building Type:
User
Conditioned Area: 3994
Lot #
Total Stories: 1
Block/SubDivision:
Owner:
# of Units:
1
Worst Case: No
PlatBook:
Street: 795 FORT WALTON A
Builder Name:
Rotate Angle: 0
Cross Ventilation: No
County: ST. LUCIE COUNTY
Permit Office:
Whole House Fan: Yes
City, State, Zip: FT. PIERCE,
Jurisdiction:
FL,
Family Type:
Single-family
NewlExisbng:
Existing (Projected)
Comment:
CLIMATE
IECC Design Temp
Int Design
Temp Heating Design Daily Temp
Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL,
Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90
70
75 722 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1819 14552
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1819 14552 Yes 4
2
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 220 ft 0
1619 ft=
0 0 1
ROOF
Roof Gable Roof
Solar
SA Emift Emitt Deck Pitch
#
Type
Materials Area Area Color
Absor.
Tested Tested Insul. (deg)
1
Hip Composition shingles 1970 ft2 0 ft2 Medium
0.96
No 0.9 No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300
1819 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 1819 fN
0.11 Wood
1116/2013 2:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
WALLS
Cavity Width Height
Sheathing
Framing Solar
Below
G o
Adjacent
Space
1 N
Exterior Concrete Block - Ext Insul Main
4.09999 49 8
392.0 ft=
0
0 0.75
0
_
2 E
Exterior Concrete Block - Ext Insul Main
4.09999 48 8
384.0 ft2
0
0 0.75
0
_
3 S
Exterior Concrete Block - Ext Insul Main
4.09999 49 8
392.0 ftz
0
0 0.75
0
_
4 W
Exterior Concrete Block - Ext Insul Main
4.09999 48 8
384.0 ft2
0
0 0.75
0
DOORS
-_ -#-
Omt-
Door Type - Space
-Storms U-Value -
Ft
Width
In
Height
Ft - In
Area
1
N
Insulated Main
None .46
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Overhang
/
V #
Wall
Omt ID Frame
Panes NFRC
U-Factor SHGC Area
Depth
Separation
Int Shade
Screening
1
N 1 Metal
Single (Tinted) Yes
1.07 0.5 64.0 ft'
2 ft 0 in
6 it 0 in
Drapes/blinds
None
2
E 2 Metal
Single (Tinted) Yes
1.07 0.5 24.0 ft2
2 ft 0 in
6 ft 0 in
Drapes/blinds
None
3
S 3 Metal
Single (Tinted) Yes
1.07 0.5 20.0 ft2
2 ft 0 in
6 ft 0 in
Drapes/blinds
None
4
S 3 Metal
Single (Tinted) Yes
1.07 0.5 20.0 ft2
2 it 0 in
6 ft 0 in
Drapes/blinds
None
5
S 3 Metal
Single (Tinted) Yes
1.07 0.5 15.0 ft2
2 ft 0 in
6 ft 0 in
Drapes/blinds
None
6
W 4 Metal
Single (Tinted) Yes
1.07 0.5 12.0 ff
2 ft 0 in
6 ft 0 in
Drapes/blinds
None
7
W 4 Metal
Single (Tinted) Yes
1.07 0.5 40.0 ft'
2 It 0 in
6 ft 0 in
Drapes/blinds
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
380 f F
380 f12
20 it
8 ft
11
INFILTRATION
SLA
CFM 50 ELA EgLA
ACH
ACH 50
=WholehouseBest
.0005
2385.6 130.97246.3
.365
9.8363
HEATING SYSTEM
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat None
COP: 1
27 kBhdhr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Air Flow
SHR Block
Ducts
n 7C i
Q%tQ*l
1 Central Unit None JttK: i0 ow.c ADLW111 .... - I
11/6/2013 2:04 PM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
HOT WATER SYSTEM
Type SubType
LocationEF Cap Use
SetPnt
Conservation
c None
Garage 0.9240 gal 50 gal
120 degNone
;FSEC
SOLAR HOT WATER SYSTEM
Collector
Storage
pany Name
System Model # Collector Model
# Area
Volume
FEF
ftz
None None
DUCTSSupply
—
— Retum —
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location Area Leakage Type
Handler
TOTOUT
QN
RLF
Heat Cool
Attic 6
r,00g:
363.8 ft
Attic 90.95 ft Default Leakage
Attic
(Default) (Default)1TEMPERATURES
amable Thermostat: Y
Ceiling Fans:[
Jan Feb
Heating Jan Feb
Mar
Mar
[ ]
[ ]Apr
Apr [ ]May [X] fee [X jul
[ ]May [ ] `
ri Aug
Aug
Se Oct
P W
ri Se Oct
Nov
Nov
NX Nov
jg
[X] Dec
[ l Dec
Jan Feb
X Mar
[X]
Apr [) Ma [ ] Jun l Jul
Venting
Thermostat Schedule: HERS 2006 Reference
Hours
7
8 9
10
11
12
Schedule Type
1
2
3 4 5 6
Cooling (WD) PM
78
80
78
78 78 78 78
78
78 78
78
78
78
Cooling (WEH) Am
78
78
78
78 78 78
78 78 78 78
78
78
78 78
78 78
8
78
8
78
78
78
PM
Heating(WD) AM
78
66
68
66
68
66 66 66 68
68 68 68 68
68
68
68 68
68 68
68
68
68
66
68
66
PM
Heating(WEH)
PM
66
66
68
66 66 6 68
68 68 68 68
6868
68
68
8
68
68
66
68
66
68
11/6/2013 2:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 795 FORT WALTON AVE. PERMIT #:
FT. PIERCE, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC=rated as meeting ASTM E 283. Windows and
doors = 0.30 cfmisq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating
controls
and cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies
in Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R-2 + accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
1 405.2.1
R-19 space permitting.
11 /6/2013 2:04 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 80
The lower the EnergyPerformance Index, the more efficient the home.
795 FORT WALTON AVE., FT. PIERCE, FL,
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows** Description
a. U-Factor: Sgl, U=1.07
SHGC: SHGC=0.50
b. U-Factor: NIA
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
Existing (Projecte
9. Wall Types
Insulation
Area
a. Concrete Block - E)t Insul, Exterior
R=4.1
1552.00 ft2
Single-family
b. N/A
R=
ftz
1
c. N/A
R=
ftz
2
d. N/A
R=
ftz
10. Ceiling Types
Insulation
Area
No
a. Under Attic (Vented)
R=30.0
1819.00 ftz
3994
b. N/A
R=
ftz
c. N/A
R=
ftz
Area
11. Ducts
R ftz
195.00 ftz
a. Sup: Attic, Ret: Attic, AH: Attic
6 363.8
ftz
12. Cooling systems
kBtu/hr
Efficiency
ftz
a. Central Unit
34.2
SEER:16.00
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
fiz
13. Heating systems
a. Electric Strip Heat
2.000 ft.
0.500
Area
14. Hot water systems
1819.00 ftz
a. Electric
ftz
b. Conservation features
f 2
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
kBtu/hr Efficiency
27.0 COP:1.00
Cap: 40 gallons
EF: 0.92
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
J
K
7905 FORT WALTON AVENUE
G . F E
EXTERIOR DOOR SCHEDULE
1 FRONT DOOR
3068
2 HOUSE to GARAGE
2868
3 SLIDING GLASS
6068
WINDOW SCHEDULE
WIDTH
HEIGHT
A 35.5"
X
62.5"
Bl 25"
X
62"
B2 51"
X
62"
83 25"
X
62"
C 51"
X
49.5"
D 35.5"
X
49 3/4"
E 46.5"
X
59 3/4"
F 46.5"
X
59 3/4"
G 46.5"
X
59 3/4"
H 51.5"
X
49.5"
1 25"
X
49.5"
J 51.5"
X
50"
K 51.5"
X
50"