Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: ES DV RECEIPT #: Permit #: Planning & Development Services Department �- O/50s p Building & Code Regulation Division S o e 2300 Virginia Avenue CANNED Ft. Pierce, FL 34982-5652 B y Tel. 772462-1553 APPLICATION FOR ROOF PERMIT st LuC1° County 6 3 SEE REVERSE SIDE FORJ[JSUCTIONS 1. Location/SiteAddress: ! //��T�,P�a�v 2. Parcel ID Number: R 3l3 - /,;4e- 000y- O00 -G 3. 4. Office Use only t �NR' 1 IWI ��11Kul1 iX Description of Projector Work Activity: / -�-�t� �/rcF/%077, Total Roof Area (square feet): 3tl00 5. Roof Pitch: OIZ2 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel Modified Bitumen V] Other 57 v Cr,mp [?�]Product Approval required for all types of Roofing Material (2 Sets) Me4xkL ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: IWICHA—El- r- PST 4,V ' FL Reg/Cert #• Address: & �--450-N AD • County Cert #: City: ;Fae-7 f/ E Z. C is State: Fl- Zip: 3 se9y7 Phone: 72D. - Sao'- o 5e07 9. Value of Construction: $ l 6, �00 Cc C lama,, n o2 31b?5 Business Name: Cell Phone: ��t/gv�ye�P�Par�Frv�C� 71S•V • cav►') "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable regulating construction and zoning. PRINT QUALIFIERS/OWNERS NAME SIlGNNATURE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF � ke A O EDGED BEFORE ME THIS DAY OF 20 / q, BY `ta It r A H I ERSON LLY TO OR HAS P UCED �. '�J3 XNTIFICARfi NA ALTMAN Notary Public - State of Florida My Comm. Expires Apr 14, 2016 NATURE OF N AR TYPE OR PRINT NAME OF NOTARY .'''�Of F��Commission # EE 177163 Bonded Through National Notary Assn. COMMISSION NUMBER NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 JOSEPH E. SMITH, CLERKOFTHE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 3915155 OR BO(� °595 PAGE 1092, Recorded 01/14/2014 10:23 AM Permit No, State of Florida County of St. Lucie NOTICE OF COMMENCEMENT Tax Folio No. 031.3 ay - 00 -y- 000- � The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, / the following Information is provided in this Notice of Commencement. 3 s a 9 S 1AC �� a Ac `� a 6Ac Legal Description of Property: (and street address if liable): /vt' Yv C,.o. Ac 0,9 9YY' _(do3 a s P, l �s 4.0 G.L ;r r'�. G1 3,/4,gl General description of Improvement: A/ tw 0tr7P Owner Information or Lessee Information If the Lessee contracted for the Improvement: Name M+cAce L t' P4Km y✓ Address Co 3 Ir P ��5.� ,:_ 3 v q (67 Interest in property: OW- I)EA _ Name and address of fee simple titleholder (if different from Owner listed above): Contractors Name: D/gU -T—, Contractor Address: /L2o .czw &,4vC!`r _Wrr `ti cr% Phone Number: In - Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ Name and address: Phone number: Lender Name: Phone Number. Lenders address: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1) (a)7., Florida Statutes: Name: Phone Number: Address: In addition to himself or herself, Owner designates Uenors Notice as provided In Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTSTO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SiTE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my =1edgeief. X ignature of Owner or Lessee, o Owners or Lessee's Authorized Officer/Director/Partner/Manager QC.clt!� (Signatory's Title/Office) The foregoing Instrument was acknowledged before me this R day of��' , 20 -';' gy /Cf CRP£ as QC4.).oER for of Person Type of authority (e.g. officer, trustee) Parry on behalf of whom Instrument was executed Personally known_ or produced Identification_ (Signature of Notary Public - State of Florida) � Wary Public quits of Fb,ie� (Print, Type, or Stamp Commissioned Name of Nota Iy l Lynn Ellen Butcher T f Identification produced Q My Commiwion EE 539117 Oi Erpirn 1Ntoliole STATE OF FLORIDA ST. LUCIE COUNTY Tu:"a; Tn r.l=;:'flrV TMATTMIS IS A Property Appraiser - StLucie County, FL http://www.paslc.org/paslc/prc.asp?prclid=231312400040006 PROPERTY RECORD CARD Michael R Peterman Record:1 of 1 <<Prev Next» Spec.Assmnt Taxes Exemptions Pernrts Horne Print Property identification Site Address: 6395 PETERSON RD ParcellD: 2313-124-0004-000-6 Sec/Town/Range: 13 :35S :39E Account #: 13675 Map ID: 23/13N Use Type: SF Res Q Zoning: AR-1 - CO City/Cnty: Saint Lucie County Ownership and Mailing Legal Description Owner. Michael R Peterman Teresa K Peterman 13 35 39 S 1 AC OF N 2 AC OF S 3AC OF W 1/2 OF E 1/2 OF NW 1/4 OF Address: 6395 Peterson Rd NE 1/4 (1.00 AC) (OR 944-261) — - Fort Pierce FL-34947-4319 - - - - Sales Information Assessment 2013 Total Land and Building Date Price Code Deed Book/Page 2013 TRIM: 98800 Land Value: 12800 Acres: 1 2/17/1995 15000 00 WD 0944 / 0261 Assessed: 98800 Building Value: 86000 4/1/1976 10000 00 CV 0251 / 1299 Ag.Credit: 0 Finished Area: 1641 SgFt Exempt: 50000 Taxable: 48800 Taxes: 1169.72 BUILDING INFORMATION 1 Exterior Features View: - RoofCover: SD - Dim Shingle RootStruct: GA- Gable ExtType: HC- -HC- YearBit: 1997 Frame: - Grade: C- - C- EftYrBlt: 1997 PrimeWall: WS - Wood/Sheath StoryHght: 0010 -1 Story No.Units: 1 Sec Wall: - Interior Features BedRooms: 3 Electric: MX- MAXIMUM PrmintWall: DW - Drywall FullBath: 2 HeatType: FHA- FrcdHotAir AvgHYFI: 1/2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: CU - Carpet %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Iterns Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Use Type Type Measure Depth ENC2 - POOL ENC-AVG Y 1 605 AV AV 2004 1 0100-SF Res 537 -Acres 1 SWAV - RES POOL AVG Y 1 240 AV AV 2004 PA01 - POOL DK-AVG Y 1 365 AV AV 2004 PHTR - POOL HEATER Y 1 1 AV AV 2004 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. 1 of 1 10/25/2013 6:24 AM Planning 8s Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 349182 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPEMON AFFIDAVIT Re: Permit # 1, licensed asIFS)C� ontractor* ngineer/Architect (Please print name & circle license type) ul ding Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about 313o? 1 .201* ,1 did personally inspect the roof deck nailing (Date) %� / {� work at: jam ,3q 5- 1-PT,eYsoh 1c� (Job site address) Based upon that examination I have determined the installation was done according to the current edition of the Florida Existing Building Code Section 611 or the product approval submitted (whichever is most strigent). Signature and Seal License # STATE OF FLORIDA COUNTY OF n Sworn to and subscribed before me this day of A--pr l 1 20jq by ilr U Who is personally known to me or who has produced �t-`�Yldrrt'S L1CC'i7� as identification. Notary Public, State of F o ida Signature of Notary: 'U .off>RYPt, e1,., JENNIFER WETTER Commission Number'"E E U-1 I -"IQ (s ahy Notary Public - State of Florida o My Comm. Expires Sep 1, 2015 :Nf CCU En 01/19/2011 Commission # EE 127172 Bonded Through National Notary Assn, RECEIVED APR 012014 Joe Cicio From: Dan Butcher Roofing, Inc. <danbutcherroofing@msn.com> Sent: Monday, March 17, 2014 2:28 PM To: Joe Cicio Subject: RE: Permit Number 1401-0146 Attachments: FL10626_R8_II_er012813FINAL_GAF_Underlayments_FL10626-R8 (VersaShield).pdf Joe, We will be using VersaShield as the fire barrier. Attached is the Florida Building Code Product Approval #FL10626-R8 for the VersaShield. The VersaShield will go between the 30# felt and the metal roof. Any other questions or info needed, please contact me. Thank you, Dan Butcher Dan Butcher Roofing, Inc. From: cicioi@stlucieco.orR To: danbutcherroofing@msn.com CC: cicioi@stlucieco.org Subject: Permit Number 1401-0146 Date: Mon, 17 Mar 2014 15:14:14 +0000 Dan, I still need the fire barrier for the metal roof system, Please e-mail me the product approval and address comment #6 . Everything else seems to be in order Thanks Jasepk A. Gdctiv, Plans Examiner II Standard Building Inspector Building Plans Examiner One and Two Family Dwelling Inspector One and Two Family Plans Examiner St. Lucie County Planning and Development Services 772-462--155 772-462--1553 Jet v���evaed� G �eY►e�redBy� � s Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and 1 1 or copying. Your e-mail communications will be subject -To public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 QOTRINITYIERD 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX:(203) 262-9243 EVALUATION REPORT GAF 1361 Alps Road, Building 7-3 Wayne, NJ 07470 Evaluation Report 01506.04.08-118 FL10626-R8 Date of Issuance: 04/25/2008 Revision 8: 01/28/2013 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: GAF Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD 'Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 + _ The facsimile seal appearing was authorized _ .. `_r�_`pF✓✓: j j�4 r by Robert Nieminen, P.E. on 01/28/2013 IV -` This does not serve as an electronically signed document. Signed, sealed hardcoples have been �ftpL+�++`T transmitted to the Product Approval Administrator and to the named client - CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations -/ Conditions of Use set forth herein. - - 2. STANDARDS: Section Property Standard Year 1507.2.4, 1507.2.9.2, Physical Properties ASTM D1970 2001 1507.5.3, 1507.2.3 Physical Properties ASTM D6757 2007 1523.6.5.2.1 Physical Properties TAS 103 1995 1507.3.3 Installation Practice FRSA/TRI 07320 2005 3. REFERENCES: Entity Examination Reference Date ERD (TST 6049) Physical Properties G12210.06.09 08/03/2009 PRI (TST 5878) Physical properties GAF-026-02-01 03/26/2002 PRI (TST 5878) Physical properties GAF-027-02-01 03/26/2002 PRI (TST 5878) Physical properties GAF-042-02-02 03/12/2004 PRI (TST 5878) Physical properties GAF-042-02-01 06/03/2005 PRI (TST 5878) Physical properties GAF-154-02-01 02/06/2007 PRI (TST 5878) Physical properties RGM-023-02-01 02/09/2007 PRI (TST 5878) Physical properties ELK-311-02-01 09/11/2007 PRI (TST 5878) Physical properties GAF-238-02-01 03/03/2010 PRI (TST 5878) Physical properties GAF-275-02-01 11/11/2010 PRI (TST 5878) Physical properties GAF-349-02-01 06/19/2012 ITS (TST 1509) Physical properties 3077464-002 09/14/2005 ITS (TST 1509) Physical properties 3077464-02 01/09/2006 UL (TST 1740) Physical properties 02NK22569 06/04/2002 UL (TST 1740) Physical properties 1ONK11990 05/18/2011 Miami -Dade (CER 1592) HVHZ compliance 11-1110.09 01/26/2012 ICC-ES (EVL2396) IBC compliance ESR-1322 01/01/2011 UL, LLC. (QUA 9625) Quality Control Inspect, File R10689, Hickory, NC 05/30/2012 UL, LLC. (QUA 9625) Quality Control Inspect, File R10689, Fresno, CA 08/24/2012 UL, LLC. (QUA 9625) Quality Control Inspect, File R1306, Conover, NC 08/29/2012 UL, LLC. (QUA 9625) Quality Control Inspect, File R1306, N. Bay, ON 09/05/2012 UL, LLC. (QUA 9625) Quality Control Inspect, File R10689, Conover, NC 09/06/2012 UL, LLC. (QUA 9625) Quality Control Inspect, File R10689, N. Branch, NJ 09/25/2012 UL, LLC. (QUA 9625) Quality Control Inspect, File R10689, Mt. Vernon, IN 10/01/2012 UL, LLC. (QUA 9625) Quality Control Inspect, File R10689, Mission, BC 10/18/2012 UL, LLC. (QUA 9625) Quality Control Inspect, File R10689, Pryor, OK 10/23/2012 4. PRODUCT DESCRIPTION: 4.1 Self -Adhering Underlayments: 4.1.1 LibertyTM SBS Self -Adhering Base/Ply Sheet is a smooth -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen roof underlayment. 4.1.2 Ruberoid@ SA Base/Ply Sheet is a smooth -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen roof underlayment. Exterior Research and Design, LLC. Evaluation Report 01506.04.08-R8 Certificate of Authorization #9503 FL10626-R8 Revision 8: 01/28/2013 Page 2 of 9 4.1.3 StormGuard@ Leak Barrier is a film -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen roof underlayment. StormGuard@ is also used as a secondary water barrier to seal roof decks. 4.1.4 UnderRoofTm 2 Leak Barrier is a spun -bond -glass -reinforced -polyester -mat -surfaced, composite -reinforced, SBS self -adhering modified bitumen roof underlayment. 4.1.5 UnderRoofTm HT Leak Barrier is a polyester -mat -surfaced, fiberglass -reinforced, self - adhering SBS modified bitumen roof underlayment. -- - -- 4.1-6 — Weather Watch® Leak Barrier is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen roof underlayment. WeatherWatch@ is also used as a secondary water barrier to seal roof decks. 4.1.7 Weather Watch@ XT Leak Barrier is a coated -mat -surfaced; fiberglass -reinforced, self - adhering SBS modified bitumen roof underlayment. 4.1.8 StormFlashTM is a polyester surfaced, fiberglass reinforced, self -adhering SBS modified bitumen sheet material for use as a moisture barrier. May be used as a secondary water barrier to seal roof deck systems. 4.2 Mechanically Fastened Underlayments: 4.2.1 VersaShield@ Underlayment or VersaShield@ Fire -Resistant Roof Deck Protection is a non -asphaltic, fiberglass -based roof underlayment and/or fire barrier. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.3 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop GAF Roof Underlayments are follows: 5.4.1 TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile — -- Metal> Wood Shakes & Shingles Slate or Simulated Slate �SaShieldg r Yes No No j o �' No No Liberty'"' SBS Base/Ply Yes No No No No No Ruberoid@ SA Base/Ply Yes No No No No No StormGuard@ Yes No No Yes No No UnderRoof'" 2 Yes Yes Yes See 5.4.1 No No Yes UnderRoof" HT Yes No No Yes No No Weather Watch@ Yes No No No No No Weather Watch@ XT Yes No No No No No "Foam -On Tile" is limited to use of Polyfoam PolyPro AH160 unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. Exterior Research and Design, LLC. Evaluation Report 01506.04.08-RS Certificate of Authorization #9503 FL10626-R8 Revision 8: 01/28/2013 Page 3 of 9 5.5 Allowable substrates for LibertyTM SBS Self -Adhering Base/Ply Sheet; Ruberoid@ SA Base/Ply Sheet; StormGuard@ Leak Barrier; UnderRoofTM 2 Leak Barrier; UnderRoofTM HT Leak Barrier; Weather Watch@ Leak Barrier; Weather Watch@ XT Leak Barrier and StormFlashTm are noted below: 5.5.1 Direct -Bond to Deck: ➢ New untreated p-lywood; _ - - ➢ Existing untreated ASTM D41 primed plywood. 5.5.2 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. 5.5.2.1 Maximum Desion Pressure = -45 Dsf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Underlayment: UnderRoofT" 2 Leak Barrier, self -adhered 5.5.3 Bond to Mechanically Attached Base Underlayment: ➢ ASTM D226, Type II felt. ➢ StormSafeT" Anchor Sheet For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.5.4 Bond to Other Substrate Types: ➢ ASTM D41 primed metal (flashing metal, valley metal, etc.) 5.6 Exposure Limitations: 5.6.1 LibertyTM SBS Self -Adhering Base/Ply Sheet; Ruberoid@ SA Base/Ply Sheet; StormGuard@ Leak Barrier; UnderRoofTM HT Leak Barrier; Weather Watch@ Leak Barrier; Weather Watch@ XT Leak Barrier; and StormFlashTM shall not be left exposed for longer than 30-days after installation. 5.6.2 VersaShield@ Underlayment; VersaShield@ Fire -Resistant Roof Deck Protection and UnderRoofTM 2 Leak Barrier shall not be left exposed for longer than 180-days after installation. 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief titled 'Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of 02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems. Exterior Research and Design, LLC. Evaluation Report 01506.04.08-118 Certificate of Authorization #9503 FL10626-R8 Revision 8: 01/28/2013 Page 4 of 9 6 TABLE 2: TILE SYSTEM OPTIONS PER FRSA/TRI 07320/8-05 System Underlay Option Section Reference Roof Underlayment(s) System One: Self -Adhered Mechanically Fastened 5 3.02E Underlayment UnderRoof'" 2 Tile, Unsealed or Sealed Underlayment_ 6 3.02F No. 30 / Self -Adhered _ Base Layer: ASTM 226, Type II felt or StormSafeT" System -- Underlayment Top Layer: UnderRoofT" 2 System Two: 4 3.02D Self -Adhered UnderRoofT" 2 Mechanically Fastened Underlayment Tile, Sealed 5 3.02E No. 30 / Self -Adhered Base Layer: ASTM 226, Type II felt or StormSafeT" Underlayment System Underlayment Top Layer: UnderRoofT" 2 System Four "A": 4 3.02D Self -Adhered UnderRoofT" 2 Adhesive -Set Tile, Underlayment Unsealed or Sealed 5 3.02E No. 30 / Self -Adhered Base Layer: ASTM 226, Type II felt or StormSafe@ Underlayment System Underlayment Top Layer: UnderRoofT" 2 System Four "B": 3 3.02C Self -Adhered UnderRoofT" 2 Adhesive -Set Tile, Underlayment Sealed Underlayment No. 30 / Self -Adhered Base Layer: ASTM 226, Type II felt or StormSafe@ System 4 3.02D Underlayment Top Layer: UnderRoof " 2 INSTALLATION: 6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Install self -adhering underlayments when ambient temperatures are minimum 450F and rising. 6.4 All metal surfaces shall be primed with TopCoat@ Matrix'"' 307 Premium Asphalt Primer or alternate GAF accepted ASTM D41 primer prior to application of self -adhering membranes. 6.5 VersaShieldT" Underlayment or VersaShieldO Fire -Resistant Roof Deck Protection: 6.5.1 Install VersaShield@ Underlayment or VersaShield@ Fire -Resistant Roof Deck Protection in compliance with manufacturer's published installation instructions and the requirements for ASTM D6757 underlayment in FBC Section 1507.2.3 for the type of prepared roof covering to be installed. A double layer is required for 2:12 < roof slope < 4:12. No hammer tacks or staples are permitted 6.5.2 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of LibertyT"' SBS Self -Adhering Base/Ply Sheet; Ruberoid@ SA Base/Ply Sheet; StormGuard@; UnderRoofT" 2; UnderRoof l HT; Weather Watch@ or Weather Watch@ XT at vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At other areas, install the leak barrier over the underlayment. Exterior Research and Design, LLC. Evaluation Report 01506.04.08-1118 Certificate of Authorization #9503 FL10626-RB Revision 8: 01/28/2013 Page 5 of 9 6.6 LibertyTM SBS Self -Adhering Base/Ply Sheet or Ruberoid SA Base/Ply Sheet: 6.6.1 Install LibertyTM SBS Self -Adhering Base/Ply Sheet or Ruberoid SA Base/Ply Sheet in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.6.2 The minimum and maximum_ roof slopes_ are 1/2:12 and 6:12, respectively. Back -nailing -.is required when slope is 1.12 or greater. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. within 3-inch side laps. 6.6.3 For non -tile applications: direct to deck: For direct -bond to deck applications plywood shall be primed with TopCoatO MatrixT"^ 307 Premium Asphalt Primer or alternate GAF accepted ASTM D41 primer at 1/2 to 3/4 gallon per square. Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Roll out sheet and allow to `relax' for min. 30 minutes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of TopCoatO Matrix1m 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 18-inch apart. Use a weighted lawn or linoleum roller to ensure complete adhesion to the substrate. Use a hand roller to firmly bond side and end laps. 6.6.4 For non -tile_ applications, to mechanically attached anchor sheet: Install ASTM D226, Type II felt in accordance with codified requirements or StormSafeT"" Anchor Sheet in accordance with Section 6.6. Install LibertyT`" SBS Self -Adhering Base/Ply Sheet or Ruberoid SA Base/Ply Sheet over the mechanically attached anchor sheet as noted above. 6.7 StorrnGuardO Leak Barrier: 6.7.1 Install StormGuard@ Leak Barrier in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.7.2 Back -nailing is required. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. within 3-inch side laps. 6.7.3 For non -tile applications, direct to deck: Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2- inch over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of TopCoatO MatrixTm 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 18-inch apart. Use a hand roller to firmly bond side and end laps. Exterior Research and Design, LLC. Evaluation Report 01506.04.08-118 Certificate of Authorization #9503 FL10626-RB Revision 8: 01/28/2013 Page 6 of 9 TRIi rry I ERD 6.7.4 For non -tile applications, to mechanically attached anchor sheet: Install ASTM D226, Type II felt in accordance with codified requirements or StormSafeTM Anchor Sheet in accordance with Section 6.6. Install StormGuard® Leak Barrier over the mechanically attached anchor sheet as noted above. 6.8 UnderRoofTM 2 Leak Barrier: 6.8.1 Install UnderRoofTM 2- Leak Barrier in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.8.2 The minimum and maximum roof slopes are 2:12 and 12:12, respectively. Back -nailing is required when slope is 4:12 or greater. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 12" o.c. within 4-inch side laps. 6.8.3 For the roof installations: Reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted herein as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 6.8.4 For non -tile applications, direct to deck: Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2- inch over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of TopCoat@ MatrixTM 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 4-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 3-feet apart. End laps shall be sealed with a 1/161h to 1/81h inch thick trowel application of TopCoat@ MatrixTM 201 Premium SBS Flashing Cement. Use a hand roller to firmly bond side and end laps. 6.8.5 For non -tile applications, to mechanically attached anchor sheet: Install ASTM D226, Type II felt in accordance with codified requirements or StormSafeTM Anchor Sheet in accordance with Section 6.6. Install UnderRoofTM 2 Leak Barrier over the mechanically attached anchor sheet as noted above. 6.9 UnderRoofTM HT Leak Barrier: 6.9.1 Install UnderRoofTM HT Leak Barrier in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.9.2 The minimum and maximum roof slopes are 1:12 and 12:12, respectively. Back -nailing is required when slope is 4:12 or greater. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 12" o.c. within 4-inch side laps. Exterior Research and Design, LLC. Evaluation Report 01506.04.08-118 Certificate of Authorization #9503 FL10626-RB Revision 8: 01/28/2013 Page 7 of 9 6.9.3 For non -tile applications, direct to deck: Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2- inch over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements: Install 1/8-inch troweling- of TopCoat@ FlexSeal" Caulk Grade over drip edge. Continue upslope in a similar manner, maintaining minimum 4-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 3-feet apart. Use a hand roller to firmly bond side and end laps. 6.9.4 For non -tile applications, to mechanically attached anchor sheet: Install ASTM D226, Type II felt in accordance with codified requirements or StormSafeTM Anchor Sheet in accordance with Section 6.7. Install UnderRoof m HT Leak Barrier over the mechanically attached anchor sheet as noted above. 6.10 Weather WatchO or Weather WatchO XT Leak Barrier: 6.10.1 Install Weather Watch@ or Weather Watch@ XT Leak Barrier in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.10.2 Weather Watch@ Leak Barrier may be installed as a secondary water barrier using minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system. 6.10.3 Back -nailing is required. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c. within 4-inch side laps. 6.10.4 For non -tile applications, direct to deck: Prior to removal of release film, align sheets properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2- inch over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of TopCoat@ MatrixTm 201 Premium SBS Flashing Cement over drip edge. Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps. Ensure all end laps are staggered at least 18-feet apart: Use a hand roller to firmly bond side and end laps. 6.10.5 For non -tile applications, to mechanically attached anchor sheet: Install ASTM D226, Type II felt in accordance with codified requirements or StormSafeTM Anchor Sheet in accordance with Section 6.6. Install Weather Watch@ or Weather Watch@ XT Leak Barrier over the mechanically attached anchor sheet as noted above. Exterior Research and Design, LLC. Evaluation Report 01506.04.08-118 Certificate of Authorization #9503 FL10626-R8 Revision 8: 01/28/2013 Page 8 of 9 `J TRINITY I ERD 6.11 StormFlashTM: 6.11.1 Install minimum 4-inch wide StormFlashTM in compliance with manufacturer's published installation instructions over the joints of the plywood roof deck prior to installation of subsequent mechanically attached or self -adhering underlayments. Do not overlap end or side joints; all end and side laps shall be butted firmly, flush, side -by -side. --7• ---LABELING:- Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL, LLC. - QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 01506.04.08-R8 Certificate of Authorization #9503 FL10626-R8 Revision 8: 01/28/2013 Page 9 of 9 2/7/2014 Comment: Comment: 2/7/2014 Comment: p kle elul 2!7/2014 Comment: ei� h)) � �— - 2/7/2014 2/7/2014 Comment: 2 7/2014 Comment: �i��FdG2Fi �dtf4LG� (J 'Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 6395 Peterson Rd City / State / Zip: Fort Pierce, FI 34947 Parcel #: 2313-124-0004-000/6 Zoning: RS-2 APPLICATION INFORMATION Permit Number: 1401-0146 Permit Type: ROOF - METAL CONTRACTOR INFORMATION Contractor Name: Butcher Danny S Business Name: Dan Butcher Roofing Inc Business Addr: 1620 Sw Beverly Terr City / State / Zip: Stuart, FI 34997 REVIEWS AND COMMENTS Review Tvoe Status FRONT COUNTER REVIEW COMPLETE Comment: PLANS EXAMINER REVIEW INCOMPLETE Joe Clcio 216/2014 2/7/2014 Comment: CONTRACTOR TO IDENTIFY THE SQUARE FOOTAGES OF THE FLAT AREAS AND THE SLOPED [ METAL ] AREAS OF THE ROOF WHICH TITANIUM ROOF UNDERLAYMENT ARE YOU PROPOSING CONTRACTOR TO IDENTIFY WHICH TABLE NUMBER AND SYSTEM TYPE IS PROPOSED FOR THE POLYGLASS COVERINGS' DEPENDING UPON THE SYSTEM YOU MAY BE REQUIRED TO PROVIDE UP -LIFT TESTING PER LIMITATIONS IN PRODUCT APPROVAL SUBMIT A ROOF PLAN IN DUPLICATE BY A FLORIDA LICENSED DESIGN PROFESSIONAL FOR THE FLAT ROOF SYSTEM DESIGNED PER CHAPTER 16 OF THE FLORIDA BUILDING CODE AND ASCE7-10 CRITERIA. SHOW ALL ROOF ZONES DIMENSIONED WITH THE CORRESPONDING DESIGN PRESSURES FOR EACH ZONE . ONCE THIS HAS BEEN CALCULATED WE THEN MAY APPLY THE APPROPRIATE SYSTEM WITH TESTED DESIGN PRESSURES' INCLUDE THE WINDSPEED AND EXPOSURE OF THE SITE WITHIN THE REPORT PER FLORIDA BUILDING CODE 1603 SUBMIT A ROOF PLAN BY A FLORIDA LICENSED DESIGN PROFESSIONAL IN DUPLICATE FOR THE SLOPED ROOF METAL SYSTEM. SEE DESIGN PROCEDURE IN THE PRODUCT APPROVAL SHEETS. DESIGN IN ACCORDANCE WITH FBC CHAPTER 16 AND ASCE7-10 FOR ROOF CLADDING. SHOW THE WIND SPEED AND EXPOSURE OF THE SITE IN THE REPORT PER FLORIDA BUILDING CODE 1603. SHOW ALL ROOF ZONES DIMENSIONED WITH THE CORRESPONDING DESIGN PRESSURES FOR EACH ZONE SUBMIT THE REQUIRED FIRE BARRIER N.O.A. PER THE PRODUCT APPROVAL AND ITS LOCATION WITHIN THE ROOF ASSEMBLY COMMENTS MAILED AND E-MAILED AS OF THIS DATE J,D (Z t00 REVIEW COMMENTS -5-0 1 Owner(s): Michael R Peterman / Teresa K Peterman Jurisdiction: ST LUCIE COUNTY Lot#: 1 Block: Automatic Sprinkler System? No MAR 14 2014 PERP111TTING Ste Lucie County, FL Fax Number. 772-223-1012 Email: Danbutcherroofing@Msn.0 om Reviewed By Date Started Date Completed Date Released Angela Huff 1/14/2014 1/14/2014 1/14/2014 Outlook Print Message bttps:Hsntl50.mail.live.com/mail/PrintA4essages.aspx?cpids=37Ob523.. Review Comments for Permit number 1401-0146 l of 2 From: Joe Cicio (cicioj@stlucieco.org) Sent: Fri 2/07/14 9:57 AM To: 'danbutcherroofing@msn.com' (danbutcherroofing@msn.com) Cc: Joe Cicio (cicioj@stlucieco.org) 1 attachment _ ReporLFL Review Comments Noncompliantjrfjl].pdf (25.9 KB) Dear St. Lucie County Permit Applicant, Please see the attached plan review comments which have been generated for your permit. As soon as we receive the modified plans and any additional required documentation back from the design professional, contractor or owner we will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to permitting for permit issuance. Thankyou, Jana?k M. Giriv Plans Examiner II Standard Building Inspector Buildn;g Plans Examiner One and Tfvo Family Dwelling Inspector One and Two Family Plans Examiner & Lucie CouutyPlanw*and Development Services 772-462--1553 Please We: Florida has very broad public records laws. Nbst written communications to or from County officials regarding County business are public 2/1,\ Joe Cicio From: Joe Cicio Sent: Friday, February 07, 2014 9:58 AM To: 'danbutcherroofing@msn.com' Cc: Joe Cicio Subject: Review Comments for Permit number 1401-0146 Attachments: Repo rt_FL_Review_Comments_NoncomplianQrf[1].pdf Dear St. Lucie County Permit Applicant, Please see the attached plan review comments which have been generated for your permit. As soon as we receive the modified plans and any additional required documentation back from the design professional , contractor or owner we will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to permitting for permit issuance. Thank you, JosepIv M. Gidl? Plans Examiner II Siandard Building Inspector Building Plans FYaminer One and Two Family Dwelling Inspector One and Two Family Plans Examiner St. Lucie County Planning and Development Services 772-462--1553 Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. 1 Planning.& Development Services Building &� Code Regulation Division 2300 Virginia Avenue Fort Pierce; FL. 34982 Phone:(772)462-2172 'Fax(772)462-6443 PROPERTY INFORMATION Address: 6395 Peterson Rd City I State/ Zip: Fort Pierce, FI 34947 Parcel #: 2313-124-0004-000/6 Zoning: RS-2 APPLICATION INFORMATION Permit Number: 1401-0146 Permit Type:. ROOF - METAL CONTRACTOR INFORMATION Contractor Name: Butcher Danny S Business Name: Dan Butcher Roofing Inc Business Addr: 1620 Sw Beverly Terr City / State / Zip: Stuart, FI 34997 REVIEWS AND COMMENTS Review Type FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW 2/7/2014 Comment: 2/7/2014 Comment: Comment: 2/7/2014 Comment: 2/7/2014 Comment: 2/7/2014 2/7/2014 Comment: 2/7/2014 Comment: REVIEW COMMENTS Page 1 Owner(s): Michael R Peterman / Teresa K Peterman Jurisdiction: ST LUCIE COUNTY Lot#: Stories: Block: Automatic Sprinkler System? No Fax Number: 772-223-1012 Email: Danbutcherroofing@Msn.0 om Status Reviewed By Date Started Date Completed Date Released COMPLETE Angela Huff 1/14/2014 1/14/2014 1/14/2014 INCOMPLETE Joe Cicio 2/6/2014 CONTRACTOR TO IDENTIFY THE SQUARE FOOTAGES OF THE FLAT AREAS AND THE SLOPED [ METAL ] AREAS OF THE ROOF WHICH TITANIUM ROOF UNDERLAYMENT ARE YOU PROPOSING CONTRACTOR TO IDENTIFY WHICH TABLE NUMBER AND SYSTEM TYPE IS PROPOSED FOR THE POLYGLASS COVERINGS * DEPENDING UPON THE SYSTEM YOU MAY BE REQUIRED TO PROVIDE UP -LIFT TESTING PER LIMITATIONS IN PRODUCT APPROVAL SUBMIT A ROOF PLAN IN DUPLICATE BY A FLORIDA LICENSED DESIGN PROFESSIONAL FOR THE FLAT ROOF SYSTEM DESIGNED PER CHAPTER 16 OF THE FLORIDA BUILDING CODE AND ASCE7-10 CRITERIA. SHOW ALL ROOF ZONES DIMENSIONED WITH THE CORRESPONDING DESIGN PRESSURES FOR EACH ZONE * ONCE THIS HAS BEEN CALCULATED WE THEN MAY APPLY THE APPROPRIATE SYSTEM WITH TESTED DESIGN PRESSURES * INCLUDE THE WINDSPEED AND EXPOSURE OF THE SITE WITHIN THE REPORT PER FLORIDA BUILDING CODE 1603 SUBMIT A ROOF PLAN BY A FLORIDA LICENSED DESIGN PROFESSIONAL IN DUPLICATE FOR THE SLOPED ROOF METAL SYSTEM. SEE DESIGN PROCEDURE IN THE PRODUCT APPROVAL SHEETS. DESIGN IN ACCORDANCE WITH FBC CHAPTER 16 AND ASCE7-10 FOR ROOF CLADDING. SHOW THE WIND SPEED AND EXPOSURE OF THE SITE IN THE REPORT PER FLORIDA BUILDING CODE 1603. SHOW ALL ROOF ZONES DIMENSIONED WITH THE CORRESPONDING DESIGN PRESSURES FOR EACH ZONE SUBMIT THE REQUIRED FIRE BARRIER N.O.A. PER THE PRODUCT APPROVAL AND ITS LOCATION WITHIN THE ROOF ASSEMBLY COMMENTS MAILED AND E-MAILED AS OF THIS DATE M IAh9I- � MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/sera GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: VersaShield® Fire Resistant Roof Deck Protection and VersaShield® Solo Fire Resistant Slip Sheet LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 10-0331.04 and consists of pages 1 through 3. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 11-1110.09 Expiration Date: 02/07/17 Approval Date: 01/26/12 Page 1 of 3 ROOFING COMPONENT APPROVAL Categof V:: Roofing Sub -Category: Underlayment Material: Fiberglass SCOPE: This acceptance is for VersaShield® Fire Resistant Roof Deck Protection (a.k.a "VersaShield® - Underlayment") and VersaShield® Solo FireResistantSlip Sheet (a.k.a "VersaShield Solo"), as described in this Notice of Acceptance, for use with approved prepared roof assemblies. Designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. PRODUCT DESCRIPTION: Product Dimensions Test Product Specification Description VersaShield® Fire 42" x 100' rolls ASTM D 226 Type II Non -Asphaltic fiberglass -based Resistant Roof underlayment and/or fire barrier. Deck Protection VersaShield® Solo 72" x 166.7' rolls UL790 Non -Asphaltic fiberglass -based slip Fire Resistant Slip sheet and/or fire barrier. Sheet MANUFACTURING LOCATION: Conover, NC EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials GAF-270-02-02 ASTM D 226 11/15/10 ELK-063-02-01 TAS 100 09/27/01 Underwriters Laboratories Inc. 99NK45831 UL790 03/21/00 1ONK11990 UL790 05/18/11 R19254 ASTM D 226 09/13/01 08CA37926 UL790 09/23/09 08CA49140 PRI Asphalt Technologies, Inc. ELK-069-02-01 TAS 100 03/04/02 BRY-003-02-01 TAS 117(B) 03/19/02 BRY-003-02-01 TAS 114 (H) INSTALLATION: 1. VersaShield® Fire Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip Sheet shall be installed in strict compliance with applicable Building Code. 2. VersaShield® Fire Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip Sheet shall be installed with a minimum 4-inch head lap in a shingle layer fashion. 3. VersaShield® Fire Resistant Roof Deck Protection shall be mechanically fastened with approved fasteners in compliance with Florida Building Code 1518.2 when used in lieu of a code prescribed ASTM D 226 Type II underlayment. NOA No.: 11-1110.09 Expiration Date: 02/07/17 MIA Fgwyi; COUNTY Approval Date: 01/26/12 Page 2 of 3 LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. VersaShield® Fire Resistant Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30-days-of application.-VersaShield® Solo Fire Resistant Slip -Sheet shall not be left exposed to the weather. 4. VersaShield® Fire Resistant Roof Deck Protection and VersaShield® Solo Fire Resistant Slip Sheet are a component used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. 5. VersaShield® Fire Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip Sheet may be used with any approved roof covering Notice of Acceptance listing. VersaShield® Fire Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip Sheet may be used as a component part of an assembly in the Notice of Acceptance. If VersaShield® Fire Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip Sheet is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 6. VersaShield® Fire Resistant Roof Deck Protection and VersaShield® Solo Fire Resistant Slip Sheet are a non -asphaltic underlayment that may be used as a fire barrier for prepared roof assemblies. For fire classification of specific roof assemblies using VersaShield® Fire Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire ratings of this product. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code LABELING: All packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and yellow line to identify the ASTM Standard designation; or logo and the following statement: "Miami - Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. END OF THIS ACCEPTANCE NOA No.: 11-1110.09 Expiration Date: 02/07/17 Approval Date: 01/26/12 Page 3 of 3 I � I h N I L I ;�[ 4 e Pe THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. FILE CO,PY rc.r N ST LUCI COUNTY BUILDING DIVISION REVI�WED FOR CO PLIA REVIEWED BY DATE PLANS AND PERMIT. MUST BE KE T ONTJOB OR NO INSPECTION WILL BE MADE rrr r 4- "'ar /,otom° r4 y � tV CP' N zt i ti bt !9 i 1 Florida Building Code Online rl Flo[lliaiGiTE€ ii BCIS Home ( Log In ; User Registration i Hot Topics ( Submit Surcharge ; Stats & Facts Publications I FBC Staff BCIS Site Map y, Links ;Search N Busines Prafessi nal � �� Product Approval < USER: Public User Regulation nimmr la�4l�rl!MM. , FIrt7lill Product Approval Menu > Product or Application Search > Application List > Applicatw etaii FL # ' ? Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL11651-RI Revision CON FASTENER$ OR ATTACHMENTS 2010 . THE RESPONSIEIUTY OF THE Approved CONTRACTOR OF RECORD Gulf Coast Supply & Manufacturing,, LLC. 4020 S. W. 449th Street Horseshoe Beach, FL 32648 (352) 498-7852 ray@gulfcoastsupply.com Ray Bowen ray@gulfcoastsupply.com THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY @MITI=! ALL APPLICABLE CODES. Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 4 Evaluation Report - Hardcopy Received Terrence E. Wolfe PE-44923 Keystone Certifications, Inc. 04/12/2014 Locke Bowden (l Validation Checklist - Hardcopy Received FL11651 R1 COI Letter of Certif.odf FL11651 RI COI Letter of Name chanae.pdf Standard Year http://www.floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsQFc5K%2f TrZeCSHgw99R5... 2/6/2014 Florida Building Code Online 6 FM 4471 1995 FM 4471 2010 TAS 100 1995 TAS 125 2003 UL1897 2004 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/15/2012 Date Validated 02/23/2012 Date Pending FBC Approval 02/29/2012 Date Approved 04/03/2012 Summary of Products Go to Page 0 4 Pagel/ 24 0 FL # IModel, Number or Name IDescription 11651.1 0.032" Aluminum 5V Crimp 0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 Rl II Alum 5 V Crimp Details.ydf Approved for use outside HVHZ: Yes Verified By: Terrence E. Wolfe, P.E. 44923 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-108.5PSF Evaluation Reports Other: -108.5 psf @ 12" o.c. Install per manufacturers FL11651 Rl AE Alum 5V Crimp Panel over .5 Plywood NONHVHZ Roof 2010 Format.pdf details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes 11651.2 0.032" Aluminum Gulf Lok ��15/32" 0.032" Aluminum Gulf Lok 16" Wide Roof Pan-7� el over Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R1 II Alum. Gulf Lok over.5 plywood Non HVHZ detail.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +N/A/-116.OPSF Created by Independent Third Party: Yes Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. - Evaluation Reports 116.0 psf @ 5 3/16" o.c. fastener spacing. Install per FL11651 Rl AE Alum Gulf lock over 15-32 Plywood Roof 2010 format.pdf manufacturers details. Not for use in HVHZ Zones.. Created by Independent Third Party: Yes 11651.3 —�::]1" Mechanical Lock 1" Mechanical Lock 24 Ga. 16 1/2" Wide Roof over �15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R1 II 1 Mech Lock 24 gal over .5 ply HVHZ detail.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +N/A/-138.5PSF Created by Independent Third Party: Yes Other: -71.0 psf @ 24" o.c. clip spacing. -138.5 psf @ Evaluation Reports 6" o.c. clip spacing. Install per manufacturers details. For FL11651 RI AE 1 Mech Lock 24 oa. over .5 Plywood HVHZ Roof 2010 format.ndf use in HVHZ Zones. Created by Independent Third Party: Yes http://www. floridabuilding. org/prlpr_app_dtl. aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5... 2/6/2014 C Florida Building Code Online 111651.4 111" Mechanical Lock Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.OPSF Other: -63.5 psf @ 24" o.c. clip spacing. -101.0 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. RCOW. � � I I 1" Mechanical Lock 0.032" Aluminum 16" Wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R1 II 1 in Mech Lock Alum details.odf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL11651 RI AE 1 Mech Lock Alum over .5 Plywood Created by Independent Third Party: Yes 11111651.5 111" Snap Lock 111" Snap Lock 24 Ga. Roof over 15/32" Plywood III Limits of Use - Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.OPSF Other: -67.3 psf @ 24" o.c. clip spacing. -131.0 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. 1651.6 111.5" Mechanical Lock Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 5" o.c. clip spacing. Install per manufacturers detals. For ise in HVHZ Zones. Installation Instructions FL11651 R1 II 24 ga 1 in Snap lock over .5 plywood Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL11651 R1 AE 1.0 Snap Lock 24 ga. over .5 Plywood Created by Independent Third Party: Yes 1.5" Mechanical Lock 24 Ga. 16" Wide Roof Panel over Installation Instructions FL11651 R1 II 24 ga. 1.5 in Mech Lock over .5 Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL11651 R1 AE 1.5 Mech Lock 24 ga. over .5 Plywood 11 Created by Independent Third Party: Yes �I h1651.7 1.5" Snap Lock 1.5" Snap Lock 24 Ga. Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.OPSF Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clips spacing. -116.0 psf @ 6" o.c. clips spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.8 1124 Ga. Gulf Coast Mechanical Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651 R1 II 1.5 in Snap Lock 24 Ga. details.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL11651 R1 AE 1.5 Snap Lock 24 ga. over .5 Plywood Created by Independent Third Party: Yes Ga. Gulf Coast Mechanical Seam 18" Wide over Installation Instructions FL11651 R1 II 24 Ga. Gulf Coast Mech Seam over .5 Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes ?valuation Reports FL11651 R1 AE 2 Mech Lock 24 ga. over .5 Plywood III II Created by Independent Third Party: Yes III 11111651.9 1124 Ga. Gulf Lok 1124 Ga. Gulf Lok 16" Wide over 15/32" Plywood III -imits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-96.7PSF Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. - )6.76 psf @ 5-1/8" o.c. fastener spacing. Install per nanufacturers details. Not for use in HVHZ Zones. 111651.10 1124 Ga. Gulf Seam Installation Instructions FL11651 R1 II 24 Ga. Gulf Lock over. 5 Plywood Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL11651 R1 AE 24 ga. Gulf lock over 15-32 Plywood Created by Independent Third Party: Yes Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood lins over 15/32" Plywood http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f rrZeCSHgw99R5... 2/6/2014 Florida Building Code Online 6 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5PSF Other: -93.5 psf @ 18" o.c. Install per manufacturers details. Not for use in HVHZ Zones. 11651.11 1124 Ga. Gulf Seam Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. Limits or Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5PSF Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions FL11651 R1 II 24 Ga. 1.75 Gulf Seam over 1x4 Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL11651 R1 AE Gulf Seam 24 ca. over 1x4 purlins Created by Independent Third Party: Yes 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over 15/32" Plywood InstallationInstructions FL11651 R1 II 24 Ga. Gulf Seam over. 5 Non HVHZ Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL11651 R1 AE 1.75 Snap Lock 24 aa. over .5 Plywood Created by Independent Third Party: Yes Lnstaiiation instructions FL11651 R1 II 26 Ga. 5V Crimp over .5 plywood Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL11651 R1 AE 26 Ga. 5V Panel over .5 Plywood HVHZ Created by Independent Third Party: Yes 11111651.13 1126 Ga. 5V Crimp 1126 Ga. 5V Crimp over 15/32" Plywood III Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.PSF Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf @ 16" o.c. fastener pattern. Install per manufactur details. Not for use in HVHZ Zones. 11651.14 1126 Ga. 5V Crimp Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-149.2PSF Other:-149.25 psf @ 16" o.c. fastener pattern. Install per manufacturers details. Not for use in HVHZ Zones. 11651.15 1126 Ga. Gulf Lok _imits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161.OPSF Other: -63.5 psf @ 5 3/16" o.c. fastener spacing. - 161.0 psf @ 5 3/16" o.c. fastener spacing. Install per nanufacturers details. For use in HVHZ Zones. Installation Instructions FL11651 R1 II 26 Ga. 5V Crimp over plywood Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL11651 R1 AE 5V Crimp Panel over .5 Plywood NON Created by Independent Third Party: Yes Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over Installation Instructions FL11651 R1 II 26 Ga. 5V Crimp over 1x4 purlins Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL11651 R1 AE 5V Crimp Panel over 1x4 wood purlins Created by Independent Third Party: Yes 16 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Installation Instructions FL11651 R1 II 26 Ga. Gulf Lock over .5 plywood Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL11651 R1 AE 26 aa. Gulf lock over 15-32 Plywood �I II Created by Independent Third Party: Yes 1 111651.16 1126 Ga. Gulf Lok 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f rrZeCSHgw99R5... 2/6/2014 Florida Building Code Online �I Jj Limits of Use Plywood Installation Instructions Approved for use in HVHZ: No FL11651 Rl II 26 Ga. Gulf Lock 16 in over .5 plvwood NHVHZ details.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +N/A/-63.5PSF Created by Independent Third Party: Yes Other: -63.5 psf @ 5 3/16" o.c. fastener spacing. Install Evaluation Reports per manufacturers details. Not for use in HVHZ Zones. FL11651 R1 AE 26 ga. Gulf lock over 15-32 Plywood Roof. pdf Created by Independent Third Party: Yes 11651.17 1126 Ga. PBR IF26 Ga. PBR 36" Wide over 15/32" Plywood I Limits of Use - — - Installation Instructions Approved for use in HVHZ: No FL11651 R1 II 26 Ga. PBR over .5 olywood NonHVHZ detail.ndf Verified By: Terrence E. Wolfe, P.E. 44923 Approved for use outside HVHZ: Yes j Impact Resistant: N/A Design Pressure: +N/A/-154.7PSF Created by Independent Third Party: Yes Other: -59.25 psf @ 24" o.c. fastener spacing.-154.75 Evaluation Reports psf @ 12" o.c. fastener spacing. Install per FL11651 R1 AE 26 Ga. PBR Panel over .5 plywood NONHVHZ Roof 2010 format.pdf manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes 11651.18 26 Ga. PBR 26 Ga. PBR Roof Panel over 1 x 4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R1 II 26 Ga. PBR over lx4 Durlins HVHZ details.pdf I Approved for use outside HVHZ: Yes i Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +N/A/-151.7PSF Created by Independent Third Party: Yes i Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 Evaluation Reports psf @ 12" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. FL11651 Rl AE 26 Ga. PBR Panel over lx4 HVHZ Roof 2010 format.pdf 11651.19 26 Ga. PBR Created by Independent Third Party: Yes 26 Ga, PBR Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 Rl II 26 ga. PBR over .5 plywood HVHZ Approved for use outside HVHZ: Yes detail.pdf I Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +N/A/-154.7PSF Created by Independent Third Party: Yes Other: -60.5 psf @ 24" o.c. fastener spacing.-154.75 Evaluation Reports psf @ 12" o.c. fastener spacing. Install per FL11651 R1 AE 26 Ga. PBR Panel over .5 Plywood HVHZ Roof 2010 format.pdf manufacturers details. For use in HVHZ Zones. Created by Independent Third Party: Yes 11651.20 26 Ga. PBR f 26 Ga. PBR Roof Panel 36" Wide over 1 x 4 Wood Purlins ! over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R1 II 26 Ga PBR over lx4 purlins NONHVHZ Detals.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +N/A/-151.7PSF Created by Independent Third Party: Yes Other: -94.25 psf @ 24" o.c.-151.75 psf @ 12" o.c. Evaluation Reports Install per manufacturers details. Not for use in HVHZ FL11651 Rl AE 26 Ga. PBR Panel over lx4 NONHVHZ Roof 2010 format.i3df Zones. Created by Independent Third Party: Yes Go to Page Pagel/ 2 Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not http: //www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsQFc5 K%2f TrZeC S Hgw99R5 ... 2/6/2014 Florida Building Code Online send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M sGlckM 5t'CltY2 �SxSlaTii3f,'$" a� k td".4 http://www. floridabuilding.org/prlpr_app_dtl. aspx?param=wGEVXQwtDgsQFc5K%2f ]FrZeCSHgw99R5... 2/6/2014 1' Force Engineering,& Testing Inc. 19530 Rarnblewood Drive Humble,TX 77338 Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. 26`Ga. 5V Crimp Roof Panel over 15132" Plywood Florida Product Approval # 11651.12 R1 Florida_ Building Code 2010 Per Rule 9N-3 Method: 1—D Category: Roofing Subcategory: Metal Roofing Compliance Method: 9N-3.005(1)(d) HVHZ Product Manufacturer: GULF COAST SUPPLY& MANUFACTURING, LLC. 4020 S.W. 44e Street Horseshoe Beach, Florida 32648 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator• Locke Bowden, P.E., FL #49704 9450 Alysbury.Piace Montgomery, AL 36117 Contents: Evaluation Report Pages 1— 4 cc N $ F `� *„ STATE OF ZOR stab W733Aft Pam �s!'pNAL• .*�,,�� ,fit FL# 11651.12 R1 February 23, 2012 Force Engineering & Testing Inc. 19530 Ranablewood Drive Humble,TX 77338 Compliance Statement: The productas described in this report has demonstrated compliance with the Florida. Building Code 2010,. Sections 1504.3.2, 1518.9, 1523.6.5.2.4. Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened roof panel over 15/32" Plywood decking. Non -Structural Application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2010 Section 1507.4.3. Paint Coating: Valspar Fluropon Coating (Optional) Yield Strength: Min. 50.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2010, Section 1507.4.3 Panel Dimension(s): Panel Fastener: Substrate Description: Design Uplift Pressures: Thickness: 0.018" min. Width: 24" Coverage Rib Height: 3/8" major rib Panel Rollformer: Rollformer Corp. #9-15 x 1-1/2" WoodZac w/ Zac Head with sealing washing through panel rib. ".minimum penetration through plywood Corrosion Resistance: Per Florida Building Code 2010, Section 1506.6, 1507.4.4 Min. 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2010. Table "A" Maximum Total Uplift Design Pressure: 108.5 ps 156.5 psf Fastener Pattern: Panel Rib Panel Rib Fastener Spacing: 12" Q.0 6" O.C. *Design Pressure includes a Safety Factor = 2.0. ACE, F_ O C1�t43 AV I No.44ii� • .n • STATE OF : a FL# 11651.12 R1 February 23, 2012 G 1 . Force Engineering & Testing Inc. 19530 Ramblewood Drive Humble, TX 77338 Code. Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2010, Section 1504.3.2, 1518.9, 1523.6.5.2.4. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2010, as relates to Rule 9N-3. Performance Standards: The product described herein has demonstrated compliance with: ■ TAS 125-03 ■ UL 580-06 - Test for Uplift Resistance of Roof Assemblies ■ UL 1897-04 - Uplift Test for Roof Covering Systems ■ TAS 100-95 - Test Procedure for Wind and Wind Driven Rain Resistance of Discontinuous Roof Systems ■ TAS 110-00 - Accel. Weathering ASTM G 26 / Salt Spray ASTM B 117 Reference Data: 1. TAS 125-03: UL580-94/ 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 117-0065T-07A-C, Dated 01/26/2007 2. TAS 100-95 Farabaugh Engineering & Testing, Inc. (FBC Organization # TST-1654) Report No. T130-07, Dated 02/28/2007 Report No. T215-08, Dated 07/08/2008 3. TAS 110-00: Valspar Fluropon coated metal panel testing A) ASTM G 26 by PRI Asphalt Technologies dated 01/19/2004 B) ASTM B 117 by PRI Asphalt Technologies dated 01/19/2004 4. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 9N-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. FL# 11651.12 R1 tea• STATE OF :a► • GDA sass ,,', �roi1IS11%���� February 23, 2012 Force Engineering & Tes'ting Itic. 19530 Ramblewood Drive Humble,TX 77338 Minimum Slope Range: 2:12. Minimum Slope shall comply with Florida Building Code 2010, including Section 1515.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturer's recommended details and RAS 133. Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2010 Section 1518.2, 1518.3, 1518.4. Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. Fire classification is not part of this acceptance.' Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2010 for roof cladding Wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2010 Chapter 22 for steel, Chapter 23'for wood and Chapter 16 for structural loading. C E• F- syo �ii . f.. /� •en •� No. M9� r a • STATE OF : a �'0 W- FL O RI p �` •�k`� 1 A% FL# 11651.12 Rl February 23, 2012 a The Erning Corporation General Contractors - Professional Engineers CGC - 019771 PE - 022920 CA-8327 Chief Building Official March 13, 2014 St Lucie County Building Department 2300 Virginia Avenue Ft -Pierce, -FL 34982 - - - - - - - Reference: Peterman Residence 6395 Peterson Road Fort Pierce, FL 34947 Subject: Re -roof Certification In the 468 S.F. flat roof area, the contractor may install a Polyglass Elastoflex SAV self adhered base sheet and a Polyglass Elastoflex SAP cap sheet. The tested design pressure for this system is -90 psf, which will meet the worst case (zone 3) required pressure of -76.8 psf. Please refer to the attached Evaluation report P9290.02.08-R10 for FL1654-R12, System #45, page 11/31. In addition, he will install 3,207 S.F. of 26 ga. 5-V crimp metal roof panels using #9-15X1-1/2" woodzac w/zac head screws, spaced @ 12" o.c. The tested design pressure for this system is -108.5 psf per FLI1651.12-R, which will meet the worst case (zone 3) required pressure of -76.8 psf. These assemblies are structurally capable of withstanding the forces applied during a 132 mph asd `B" exposure wind event and meets the criteria of the 2010 Florida Building code at this specific site / application. If you have ny questions, please call me at your earliest convenience. Thank you. Dr. Ernest A. Kuonen, PE 022920 President, The Erning Corporation CA-8327 802A Muirfield Court Jupiter FL 33458 802A Muirfield Court Jupiter FL 33458 Florida+Building Code Online Florida [epaamentof Busines Professi rraI Regulation a BCIS Home i Log In f User Registration I Hot Topics ( Submit Surcharge i Stats & Facts I Publications ( FBC Staff ( BCIS Site Map ( Links Search a Product Approval ;USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL1654-R12 Application Type Revision Code Version 2010 Application Status Approved Comments Archived 0 Product Manufacturer POLYGLASS USA Address/Phone/Email 150 Lyon Drive Fernley, NV 89408 (570) 384-1230 Ext242 jakins@polyglass.com Authorized Signature James Akins jakins@polyglass.com Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive Fernley, NV 98408 (602) 363-7139 stevew@polyglass.com Quality Assurance Representative James Akins Address/Phone/Email 555 Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800) 894-4563 jakins@polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer C.I Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/08/2015 Validated By John W. Knezevich, PE Cl Validation Checklist - Hardcopy Received http: //www. floridabuilding. org/prlpr_app_dtl. aspx?param=wGEVXQwtD gvgqu2w%2bnFgUPv2pw6pKx... 2/7/2014 Florida,Building Code Online S 3 Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards - Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL1654 R12 COI Trinitv ERD CI - Nieminen - 2013.ndf Standard Year ASTM D6163 2000 ASTM D6164 2005 ASTM D6222 2002 ASTM D6509 2000 FM 4470 1992 FM 4474 2004 Method 1 Option D 08/21/2013 08/26/2013 09/08/2013 10/18/2013 Summary of Products FL # Model, Number or Name IlDescription 1654.1 Polyglass SBS and APP SBS and APP modified bitumen roof systems Modified Bitumen Roof Systems Limits of Use Installation Instructions I Approved for use in HVHZ: No FL1654 R12 II Al ER082113FINAL POLYGLASS MODBIT FL1654- R12.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this Evaluation Reports application relates to one particular assembly FL1654 R12 AE ER082113FINAL POLYGLASS MODBIT FL1654- R12.Ddf over concrete deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer Created by Independent Third Party: Yes to ER, Section 5 for other Limits of Use. Back Mext Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M eCti£iY, M http://www.floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKx... 2/7/2014 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 � ! 353 Christian Street ".4 TRINITY I ER® Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P9290.02.08-1110 150 Lyon Drive __ -- - FL1654-R1-2 Fernley, NV 89408 Date of Issuance: 02/11/2008 Revision 10: 08/21/2013 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated'Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 31-page Appendix. Prepared by: i = The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 08 21 2013 This does not serve as an electronically signed Robert J.M. Nieminen P.E. r'•,�S": — "^�` document. Signed, sealed hardcopies have been ii`, �•`•'' transmitted to the Product Approval Administrator and Florida Registration No. 59166, Florida DCA ANE1983 to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. `, iT INIT Y i ER® ROOFING SYSTEMS EVALUATION: 1. ' SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Complianceis subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2004 1504.7 Impact FM 4470 1992 1507.11.2 Physical Properties ASTM D6163 2000 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2002 1507.11.2 Physical Properties ASTM D6509 2000 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties P10490.10.08-2 10/30/2008 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 ERD (TST6049) FM 4470/4474 P30550.12.09 12/02/2009 ERD (TST6049) Physical Properties P33960.12.10 12/30/2010 ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011 ERD (TST6049) Physical Properties P37590.03.13-3A 03/06/2013 ERD (TST6049) FM 4470/4474 P39680.03.13 03/04/2013 ERD (TST6049) Physical Properties P37590.03.13-1-R1 06/26/2013 ERD (TST6049) Physical Properties P37590.03.13-2-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-2 07/01/2013 ERD (TST6049) Physical Properties P37590.03.13-5-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-1 07/02/2013 ERD (TST6049) FM 4470/4474 P41630.08.13 08/06/2013 FM Approvals (TST1867) FM 4470 2W7A7.AM 08/04/1994 ' FM Approvals (TST1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3006646 01/04/2000 FM Approvals (TST1867) FM 4470 3001334 01/25/2000 FM Approvals (TST1867) FM 4470 3001334 02/15/2000 FM Approvals (TST1867) FM 4470 3000857 01/12/2000 FM Approvals (TST1867) FM 4470 3004091 01/12/2000 FM Approvals (TST1867) FM 4470 3006115 05/02/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3007170 01/13/2004 FM.Approvals(TST1867) FM 4470 3019317 06/30/2004 FM Approvals (TST1867) FM 4470 3020703 .07/30/2004 FM Approvals (TST1867) FM 4470/4474 3018332 01/31/2006 FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals (TST1867) FM 4470/4474 3024594 05/23/2006 FM Approvals (TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals (TST1867) FM 4470/4474 3030668 09/12/2007 FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009 PRI (TST5878) Physical Properties PUSA-062-02-01 12/04/2007 Exterior Research and Design, LLC. Evaluation Report 139290.02.08-1110 Certificate of Authorization #9503 FL1654-1112 Revision 10: 08/21/2013 Page 2 of 5 TRINITY ER® 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. 5. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions, ➢ HA (HA): Full coverage at 25-30 Ibs/square. ➢ Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. Note: TITESET may be used where CR-20 is referenced. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. - ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'Increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL) ➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0,5-inch thick ACFoam II) ➢ 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 7. Bonded po lyisocya nu rate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A, qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AH], as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124. 12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. Exterior Research and Design, LLC. d/b/a TrinitylERD "' ��, Evaluation Report P9290.02.08-R10 for FL1654-1112 Certificate of Authorization #9503 Revision 10: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 °i' Appendix 1, Page 2 of 31 �,ATRINITYIERD 13. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. TABLE 1: POLYGLASs ROOF COVERS Reference Layer Material Application BP -AA Base Polyglass G2 Base, FBC Approved ASTM D4601, Type II HA at 20-40 Ibs/square (Base and Ply sheets, Asphalt -Applied) Ply FBC Approved ASTM D2178, Type IV or VI or ASTM D4601, Type II SBS-AA Base or Ply Elastobase, Elastobase Poly, Elastoflex V, Elastoflex S6 HA 20-40 Ibs/square (SBS, Asphak-Applied) Cap Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko MOP, Polyfresko MOP FR at Base or Ply Elastoflex V, Elastoflex S6 SBS-TA (SBS, Torch -Applied) Cap Elastoflex V, Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko MOP, Polyfresko MOP FR Torch -Applied SBS-SA (SBS, Self -Adhering) Base Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR Self -Adhering Cap Elastoflex SA P, Elastoflex SA P FR, Polyfresko SBS SAP, Polyfresko SBS SAP FR APP-TA Base or Ply Polyglass APP Base, Polyflex, Polybond Torch (APP, Torch -Applied) Cap Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko Torch, Polyfresko Torch FR -Applied APP-SA (APP, Self -Adhering) Cap Polyflex SA P, Polyflex SA P FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Polykool, Polybianko Self -Adhering 14. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating; ➢ PG300 Fibered Roof Coating or Mule -Hide 102 Fibrated Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating; ➢ PG700 White Reflective Roof Coating; ➢ PG800 Non-Fibered Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Fibrated; ➢ PG850 Fibered Asphalt Emulsion Roof Coating or Mule -Hide 301 Emulsion Fibrated; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating; ➢ Polybrite 70 White Elastomeric Roof Coating. 15. The following represent priming requirements for gypsum -based coverboards: ➢ DensDeck and DensDeck Prime shall be field -primed with PG100 prior to self -adhering or torch -applied membrane application. No priming is required for hot -asphalt membrane applications. ➢ SECUROCK Gypsum -Fiber Roof Board or DensDeck DuraGuard do not require field priming for any membrane application. 16. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind loads. Exterior Research and Design, I.I.C. d/b/a TrinitylERD Evaluation Report P9290.02.08-1110 for FL1654-1112 Certificate of Authorization #9503 Revision 10: 08/21/2013 _ Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 3 of 31 Q(TDPuN1TY1ERD TABLE 1E: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER SyNoem Base Sheet Roof Cover MDP Deck (See Note i) Base Fasten Attach Ply Cap (psf) Min. 19/32-inch plywood 32 ga., 1-5/8-inch diameter tin 6-inch o.c. in 4-inch lap and 6- (Optional) One or more BP-AASBS- SBS-AA, W-40 at max. 24-inch spans attached 6-inch o.c. with Elastobase or Elastobase Poly caps with 11 ga. annular ring inch o.c, in four, equally , SBS-TA or APP- SBS-TA, -112.5 shank nails spaced, staggered center rows TA, APP-TA #8 screws Min. 19/32-inch plywood 32 ga., 1-5/8-inch diameter tin (Optional) One or more SBS-SA (no SBS-SA, W-41 at max. 24-inch spans Elastobase or Elastobase Poly with caps with 11 ga, annular ring shank nails. Note: Tin caps are 6-inch o.c. in 4h lap and 6- inch o.c. in four, equally Elastoflex SA V Base APP-SA -112.5 attached 6-inch o.c. with poly top surface to be primed with PG100 or spaced, staggered center rows or Elastoflex SA V FR SBS-TA or #8 screws ASTM D41 primer. Base), SBS-TA or APP-TA APP-TA Min. 15/32-inch thick OMG #12 Standard Roofgrip or OMG #14 Heavy Duty (min. 1- 6-inch o.c. at 4-inch lap and 6- W-42 exterior grade plywood Polyglass APP Base 5/8-inch long) with OMG 3" inch o.c. in five, equally (Optional) APP-TA APP-TA -120.0 attached per Code to meet Round Metal Plates or OMG Flat spaced, staggered center rows pressure requirements. Bottom Metal Plates OMG #12 Standard Roofgrip or Min. 15/32-inch thick OMG #14 Heavy Duty (min. 1- 6-inch o.c. at 4-inch lap and 6- (Optional) BP -AA, SBS-AA, W-43 exterior grade plywood Elastobase (with sand top surface) 5/8-inch long) with OMG 3" inch o.c. in five, equally SBS-AA, SBS-TA or SBS-TA or -120.0 attached per Code to meet Round Metal Plates or OMG Flat spaced, staggered center rows APP-TAT APP-TA pressure requirements. Bottom Metal Plates Min. 15/32-inch thick exterior grade plywood Trufast #12 DP orTrufast #14 6-inch o.c. at 4-inch lap and 6- (Optional) BP -AA or W-44 attached per Code to meet Elastobase (with sand top surface) HD (min. 1-5/8-inch long) with inch o.c. in five, equally SBS-AA SBS-AA -120.0 Trufast 3" Metal Insulation Plates spaced, staggered center rows pressure requirements. TABLE 1F: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER Roof Cover MDP System No. Deck (See Note 1) Primer (Psf) Joint Treatment Base Ply Cap Min. 19/32-inch plywood at W-45 max. 24-inch spans attached o.c. with 8d ring shank (Optional) PG100 None SBS-SA . (Optional) SBS-SA, SBS-TA or APP-TA SBS-SA, APP-SA, SBS-TA or APP-TA go nails Min. 15/32-inch plywood at Plywood joints are covered with 4-inch wide strips Elastoflex SA V (Optional) SBS-SA, SBS-SA, APP-SA, W-46 max. 24-inch spans attached (Optional) PG100 of Elastoflex SA V Plus, rolled into place to create Base or Elastoflex SBS-TA or APP-TA SBS-TA or APP-TA -97.5 6-inch o.c. with #12 screws continuous bond. SA V FR Base Min. 15/32-inch plywood at Plywood joints are covered with 4-inch wide strips Elastoflex SA V Plus (Optional) SBS-SA, SBS-SA, APP-SA, W-47 max. 24-inch spans attached (Optional) PG100 of Elastoflex SA V Plus, rolled into place to create or Elastoflex SA V SBS-TA or APP-TA SBS-TA or APP-TA -135.0 6-inch o.c. with #12 screws continuous bond. I Plus FR Exterior Research and Design, LLC. d/b/a TrinityJERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report P9290.02.08-R10 for FL1654-R12 Revision 10: 08/21/2013 Appendix 1, Page 11 of 31 Florida Building Code Online BCIS Home I Log In I User Registration I Hot Topics i Submit Surcharge i Stats & Facts i Publications I FBC Staff , BCIS Site Map I Links Search Product Approval 'USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL11602-R2 Application Type Revision Code Version 2010 Application Status Approved Comments Archived Product Manufacturer InterWrap, Inc. Address/Phone/Email 32923 Mission Way Mission, NON -US 00000 (778) 945-2891 elozano@interwrap.com Authorized Signature Eduardo Lozano elozano@interwrap.com Technical Representative Eduardo Lozano Address/Phone/Email 32923 Mission Way Mission, NON -US 00000 (778) 945-2891 elozano@interwrap.com Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence CONCgLEO FASTENERS OR AiACMMEI�S ARC THE 130 PORUJUTY OF THE CORTR.vOR OF RECORD THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT Roofing MAY BE NECESSARY IN ORDER TO Underlayments COMPLY WITH ALL APPLICABLE CODES, Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer O Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 Intertek Testing Services NA Inc.- ETL/Warnock Hersey 09/06/2014 John W. Knezevich, PE M Validation Checklist - Hardcopy Received FL11602 R2 COI Trinity ERD CI - Nieminen.odf http://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeHYB7UCe5... 3/17/2014 Florida Building Code Online 2 Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1507.2.3 1507.2.4 1507.2.9.2 1507.3.3 1507.5.3 1507.7.3 1507.8.3 • 1507.9.3 1507.9.5 1523.6.5.2.1 Product Approval Method Method 2 Option B Date Submitted 02/17/2012 Date Validated 04/18/2012 Date Pending FBC Approval 02/27/2012 Date Approved 04/23/2012 Summary of Products FL # Model, Number or Name Description 11602.1 IlTitanium Roof Underlayments ISynthetic sheet -type roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL11602 R2 II er021712FINAL INTERWRAP FL11602- R2.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-45 Created by Independent Third Party: Yes Other: 1.) The design pressure noted herein pertains to Evaluation Reports use of a specific underlayment system beneath foam -on FL11602 R2 AE er021712FINAL INTERWRAP FL11602- R2.pdf tile sytsems. Refer to ER Section 5.5.3 for details. 2.) Refer to ER Sections 5 and 6 for other Limits of Use. Created by Independent Third Party: Yes Back Next Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To_determine-if-you-are-a-licensee-under-Chapter-455,-F.S.,-please- click -he re . — ProductApprovalAccepts: W ® EGhEck M accuritvair'1'�xa�,;s http://www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsQFc5K%2f I'rZeHYB7UCe5... 3/ 17/2014 D I0 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 \-- i TRINITT. ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Interwrap, Inc. Evaluation Report I11980.11.08-112 32923 Mission Way - FL11602-R2 Mission, BC V2V-6E4 Date of Issuance: 11/03/2008 Canada Revision 2: 02/17/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted 'has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: TitaniumT" Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires- a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/17/2012 This does not serve as an electronically signed document. Signed, sealed ha*rdcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityJERD does not have, nor does It Intend toacquireor will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2 TrinitylERD-is-not-owned; operated -or -controlled -by -any -company -manufacturing -or -distributing protlucts-it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being Issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the product. I `,.l TRINITY I•ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: TitaniumTm Roof Underlayments, as produced by Interwrap,. Inc , have demonstrated compliance with,the intent of the following sections of the Florida Building Code through -testing in accordance with applicable sections the following Standards. Compliance is subject. to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3, 1507.3.3, 1507.5.3, ' Unrolling, Breaking Strength, ASTM D226 2006 1507.7.3, T1507.8, 1507.8.3, Pliability, Loss on.Heating 1507.9.3, 1507.9.5 1507.2.4, 1507.2.9.2, 1507.5.3 Thickness, Load -Strain, Adhesion, ASTM D1970 .. 2001 Thermal Stability, Flexibility, Tear, Permeance 1507.3.3 Installation Practice FRSA/TRI 07320 2005 1523.6.5.2.1 Dimensional Stability, Tear, Load- TAS 103 1995 Strain, Water Absorption, Low Temp Flex, Cyclic Elongation, Puncture, Crack Cycling, Peel Adhesion, WVT, Tile Slippage TAS 110 Accelerated Weathering TAS 110 2000 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties I15010.04.09 04/29/2069 ERD (TST6049) Physical Properties I15010.05.10 05/14/2010 ERD (TST6049); Physical Properties I35520.06.11 06/15/2011 ERD (TST6049) Wind Uplift I35520.08.11-1 08/12/2011 ITS (TST1509) Physical Properties 3146738COQ-003A 03/28/2008 ITS (TST1509) Physical Properties 3146738COQ-003B 03/28/2008 ITS (TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS (QUA1673) Quality Control ITS Listings. Current -ITS (QUA1673) Quality Control Inspection Report 12/13/2011 4. PRODUCT DESCRIPTION: 4.1 Self -Adhering Underlayments: 4.1.1 TitaniumTm PSU-30 is an unreinforced polymer modified bitumen material adhered to the underside of a polymer -coated, synthetic woven sheet. The underside is backed with a release film. Unit weight 24 Ibs/square. 4.2 Mechanically Fastened Underlayments: 4.2.1 TitaniumTM UDL-25 PLUS is a synthetic sheet -type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.9 Ibs/square. 4.2.2 TitaniumTm UDL-30 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating.. Unit weight 4.0 Ibs/square. 4.2.3 Titanium"4 UDL-50 is a synthetic sheet -type underlayment comprised of a woven core coated . on both sides with a polymer coating. Unit, weight 4.7 Ibs/square. Exterior Research and,Design, LLC. Evaluation Report I11980.11.08-R2 Certificate of Authorization #9503 FL11602-1112 Revision 2: 02/17/2012 Page 2 of 6 t `\_ ,¢ TRII0 IW I ERD 4 4.2.4 TitaniumTm UDL-TT is a synthetic sheet -type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.9 Ibs/square 4.2.5 TitaniumTm UDL-TF is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 2.9 Ibs/square. 4.2.6 UDL-TTMC300 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 3.2 Ibs/square. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of- this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Titaniumlm Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop TitaniumT" Roof Underlayments are follows: Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes & Shingles Slate PSU-30 Yes Yes Yes (See 5.4.1) Yes Yes Yes UDL-25 PLUS Yes Yes No Yes Yes Yes UDL-30 Yes Yes No Yes Yes Yes UDL-50 Yes Yes No Yes Yes Yes UDL-TT Yes Yes No Yes Yes Yes UDL-TF Yes Yes No Yes Yes Yes 'UDL-TTMC300 Yes Yes No Yes Yes Yes wivate Laoeieo 5.4.1 "Foam -On Tile" is limited to use of Polyfoam PolyPro AH160.or Dow Tile Bond applications unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. 5.5 Allowable substrates for PSU-30 are noted below: 5.5.1 Direct -Bond to Deck: ➢ New untreated plywood; ➢ Existing untreated plywood, primed as needed with D41 primer to achieve bond. 5.5.2 Bond to Mechanically Attached Base Underlayment: ➢ ASTM D226, Type I or II felt. ➢ Titanium UDL-25 PLUS, UDL-30 (primed with D41 primer) or UDL-30 (inverted). 5.5.3 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following -wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load-resistance-based-oTi-allowabie-wind-loads—Refer to FBI--f609-.1.5 for a ermination of design wind pressures. Exterior Research and Design, LL �. luation Report I11980.11.08-R2 Certificate of Authorization #9503 FL11602-112 Revision 2: 02/17/2012 Page 3 of 6 i I 1Q TRINITY ERt 5.5.3.1 Maximum Design Pressure = -45 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Underlayment: Titanium PSU' 30, self -adhered 5.5.3.2 Maximum Design Pressure = -45 gsf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Titanium UDL-25 PLUS or UDL-30 (inverted), mechanically attached with FBC HVHZ ring shank nails and 1-5/8" diameter tin caps spaced 6-inch o.c. at 4- inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: Titanium PSU 30, self -adhered 5.5.3.3 Maximum Design Pressure = -45 psf. Deck: Min.' 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Layer: Titanium UDL-30 (printed side up), mechanically attached with FBC HVHZ ring shank nails and 1-5/8" diameter tin caps spaced 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30.­- -Underlayment: Titanium PSU 30, self -adhered 5.6 Exposure Limitations: 5.6.1 UDL-25 PLUS, UDL-30, UDL-50, UDL-TT or UDL-TF shall not be left exposed for longer than 30-days. 5.6.2 PSU-30 shall not be left exposed for longer than 90-days. 5.6.3 UDL-TTMC300 not be left exposed for longer than 180-days. 5.7 For tile roof. installations .governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Table 2: Tile System Options per FRSA/TRI 07320/8-05 System Underlay Option • Section Reference' ' Roof Undedayment(s) 4 3.02D Two Ply No. 30 Double -layer, UDL 25, UDL 30, UDL 50, UDL TT, UDL Svstem One: TF or UDL-TTMC300 Mechanically Self -Adhered Fastened Tile, 5 3.02E Underlayment PSU 30 Unsealed or Sealed Underlayment No. 30 / Self -Adhered Base Layer: ASTM 226, Type II felt, UDL 25 PLUS, UDL System 6 3.02F Underlayment 30 (primed with D41 primer) or UDL 30 (Inverted) Top Layer: PSU 30 System Two: 4 3.02D Self -Adhered pSU 30 Mechanically Underlayment Fastened Tile, Sealed No. 30 / Self -Adhered Base Layer: ASTM 226, Type II felt, UDL 25 PLUS, UDL Underlayment 5 3.02E Underlayment 30 (primed with D41 primer) or UDL 30 (Inverted) System Top Layer: PSU 30 System Four "A":' 4 3.02D Self -Adhered ?SU 30 Adhesive -Set Tile, Underlayment Unsealed or Sealed Underlayment No. 30 / Self -Adhered Base Layer: ASTM 226, Type II felt, UDL 25 PLUS, UDL System 5 3.02E Underlayment 30 (primed with D41 primer) or UDL 30 (inverted) Top Layer: PSU 30.. System Four "B": 3 3.02C Self -Adhered. PSU 30 Adhesive -Set Tile, Underlayment Sealed Underlayment No. 30 / Self -Adhered Base Layer: ASTM 226, Type II felt, UDL 25 PLUS, UDL System 4 3.02D Underlayment 30 (primed with D41 primer) or UDL 30 (Inverted) Top Layer: PSU 30 Exterior Research and Design, LLC. Evaluation Report I11980.11.08-112 Certificate ofAuthorb-ation #9503 FL31602-R2 Revision 2: 02/17/2012 Page 4 of 6 TRINITY I ERD 6. INSTALLATION: 6.1 Titanium Roof Underlayments shall be.. installed in accordance with Interwrap published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly -to remove any_ dust and_ debris prior_ to_ application,_ and prime. the substrate_(if applicable). 6.3 TitaniumT"' PSU-30: 6.3.1 PSU-30 shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed: 6.3.2 Cut to 10- to 15-foot manageable sections and re -roll with the release film side out. 6.3.3 Membrane Application: ➢ Peel back release film approximately 1 to 2 feet and align with the lower edge of the roof and set in place, printed side up. ➢ Apply the balance of the membrane to the substrate by removing the film and firmly pressing the membrane into place. ➢ Apply subsequent courses parallel to the eave in a shingle -type, water -shedding manner. ➢ End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 3-inches. ➢ If the membrane becomes misaligned, cut the roll and re -start. ➢ Upon completion, inspect the membrane and repair any defects or fish -mouths. 6.3.4 For use in tile applications: 6.3.4.1 Reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Section 5.7 herein, using the instructions noted above as a guideline 6.3.4.2 Wait a minimum of 24 hours prior to loading roof tiles. 6.3.4.3 Tiles shall be staged so as to avoid slippage and/or damage to the roof underlayment. 6.4 Titanium"" UDL-25 PLUS, UDL-30, UDL-50, UDL-TT, UDL-TF and (Private Labeled) UDL-TTMC300: 6.4.1 Install in compliance with manufacturer's published installation instructions and the requirements for ASTM D226, Type I and II underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 Fasteners: 6.4.2.1 Mechanical attachment of UDL-25 PLUS and UDL-30 is limited to ring shank roofing nails with minimum 1-inch diameter plastic caps. 6.4.2.2 Mechanical attachment of UDL-50, UDL-TT, UDL-TF and (Private Labeled) UDL-TTMC300 is limited to ring shank roofing nails with minimum 3/8-inch diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and plates; or plastic cap staples. 6.4.3 Slopes of 4:12 or greater: 6.4.3.1 End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4- inches. Exterior Research and Design, LLC. . Evaluation Report I11980.11.08-R2 Certificate of Authorization #9503 1py FL11602-R2 € Revision 2: 02/17/2012 FILL Page 5 of 6 ` TRIIe11TY I ERD ` 6.4.3.2 Minimum attachment shall be 12-inches o.c. vertically and 24-inches o.c. horizontally in accordance with the surface markings on the, exposed face of the underlayment.. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.4.4 Slopes of 2:12 to less than 4:12: 6.4.4.1 Double layer application; begin by fastening a 25-inch .wide strip along the eaves. Place a full - width sheet over the. starter;, completely overlapping. the starter course. Continue as noted in 6.4.3, but maintaining minimum 25-inch side (horizontal) laps, resulting in a double -layer application. 6.4.5 For use. in the applications: 6.4.5.1 Reference is.made to FRSA/TRI 07320/8-05. Installation, Manual, Fourth.Edition, and Section 5.7 herein. 6.4.5.2 Titanium'1 UDL underlayments are 48-inches wide; wider than the typical, codified 36-inch wide ASTM D226, Type I and II underlayment. The placement and attachment requirements set forth_ in Sections 6.4.3.. (single layer with..PSU-30 overtop) and 6.4.4 (double -layer) are suitable to maintain the intent of FRSA/TRI 07320/8-05 Installation • Manual, Fourth Edition, Systems 1 and 2. 6.4.5.3 Tiles shall be staged so as to avoid slippage and/or damage to the roof underlayment. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA agency for information on production locations covered by F.A.C. Rule 9N-3 QA requirements. 10 QUALITY ASSURANCE ENTITY: Intertek Testing -Services NA Inc:-ETL/Warnock Hersey - QUA1673; -(604) 520-3321 . - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report I11980.11.68-112 'CertiFcate of Authorization #9503 FL11602-112 Revision 2: 02/17/2012 Page 6 of 6 C r