Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: FEES DUE: RECEIPT #: - I Permit #: ,?�J a_04 Planning & Development Services Department �COUNTY Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 CAN/V�D Tel. 772-462-1553 1 C UC 13 CO U APPLICATION FOR ROOF PERMIT SE EVERSE SIDE FOR INSTRUCTIONS n}✓ 1. Location/Site Address: co�c.s� 0?_ 2. Parcel ID Number: 3LI/9- fi3C)- WL16 - Coo_ d Office Use Only I Section I Townshi Ran a Ma Pa a -Zonin -Land-Use— -Widals 3. Description of Project or Work Activity: 4. Total Roof Area (square feet): .1( 5. Roof Pitch: r '� 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel A Modified Bitumen [ ] Other [ ] Product Approval required for all types of Roofmg Material (2 Sets) ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached Roof Mitigation per F.S. 553.844 will be required 7. Owner Informat__ion 8. Name:l'�''X'e� itin -Z Address: City: ']_ State: Zip: :3,L4 'F — Phone: 9. Value of Construction: $i Contractor Information FL Reg/Cert #: _ :k �2gQR %&% County Cert #: 1 q q C16 Business Name: '-T1et��<r_ eecaA41n CellPhone: o.eE•�s c�QECo cfsTG�.0 CO .�'05w 7" /, ✓ET "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the inflon3lation contained in this application is correct and that all work will be /�� done in compliwithyalppl'�bela regulating construction and zoning. PRIKT QUALIFIERS/OWNERS NAME S ATURE QU O R v STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS 2 DAY OF O `J 20 3 , BY WHO I ER N 4,Y KNO / TOME OR HAS DUCED AS IDENTIFI S 9*,, ...,. ROBERT J. BERQUIST MY COMMISSION I DD 975578 GNATURE 014 OP N Y TYPE OR PRINT NAME OF NOTARY (Seal) 41 0.01 �, EXPIRES: March aIY mIc • r9�Bonded Thm Budget Notary Services COAUMSSION NUMBER NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 JOSEPH E. SMITH, CLERK '— ?HE CIRCUIT COURT — SAINT LUCIE COUNmx'_ FILE # 3897926 OR BOON 19 PAGE 8, Recorded 11/14/2013 at 1,,� PM NOTICE OF COMMENCEMENT Permit No. Tax Folio No. 3411-5` 0-oo4S-000-0l State of Florida County of St. Lucle The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided In this Notice of Commencement. legal Description o(Property: (and street address If available): L"1l rJ•t F'Rt�f Ct s� DiL P % L/n� pLoTC1 al oCK 131 .SECT100 3 General description of Improvement: 1l kllO Owner Information or Lessoe Information If the Lessee contracted for the Improvement: — - -Name , __ r— r R 1 A, Address 1-7 e— SPe, ,-2f Sf.L.;c,� Interest in property: bl.:, LX. Name and address of fee simple titleholder (if different from Owner listed above): contractor's Name: 'TfLe✓ZSv2� C1�.4�'��rA� Z—`�' Contractor Address: ,,'S(IG {W kSL,f=C.. Phone Number: 77a-3�� 4y� 3rrWy Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ Name and address: Phone number: Lender Name: Phone Number: Lender's address: Persons within the State of Florida designated by Owner upon whom notices or other documents may he served as provided by Section 713.13(1) (a)7., Florida Statutes: Name: Phone Number: In addition to himself or herself, Owner designates - of Uenor's Notice as provided in Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SiTE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WiTH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare t have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowled d belief. 4-1 gnature Ownei or ess s or Lessee's Authorized Officer/Director/Partner/Manager (Signatory's Title/Office) The foregoing Instrument was acknowledged before me this-� day ofh=LQ , 20_! ByA as for ( e of erso pe of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed Personally know4or produced Identification_. (Signature of Notary Public State of Florid (Print, Type, or Stamp Co missioned Na of NotaTy,Nbeic) Type of Identification produced a° .•., ROBERTJ.BERWIST * i MY COMMISSION f DO 97557E AEXPIRES: Match 28, 2014 'rar r.�'° Baged TMu Budget Ndq StMm 6TATE Of FLORMA ST. Lii'(;IE CONTY THIS ISTOCERTIFYTI;ATTHiSISA TALIE AMID CORRECT T COPY OF THE GAIOIRAL. j Ua y1C1erk T� Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # L C� 3 a -C6 9 o* licensed as �•n)Contractor / ginger/Architect (Please print name & circle license type), *FS 8-Buildin ector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about .:), / J/ 10 1 q . I did personally inspect the roof deck nailing (Date) work at: `� ,2, •� C� S .' (Job site address) Based upon that examination I have determined the installation was done according to the current edition of the Florida Existing Building Code Section 611 or the product approval submitted (whichever is most stri ent). Sig tUre,a�d Se_a License # STATE OF FLO IDA� L--�-k- SwSoCOUNTYOF �� acd subscrib d befor me this day of byC is onally to enti 'cation. Notary Public, State f orida Signature of Notary. :j2jzect. Commission Number: En 01/19/2011 20L4 or who has produced ANGEIA M HUFF MY co'%VE 101V Bonded Thr uES; Apr1112 083530 aNPu6tic � 0ndenvrf;ere ,Florida Building Code Online Florida F)p rfm&jtd BCIS Home I Log In [ User Registration I Hot Topics ( Submit Surcharge ji Stats & Facts 1 Publications I FBC Staff I BCIS Site Map I Links I Search Busi.nes Product Approval ^fes' I USER: Public User Regulation __11111 n . Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence FL10497-R2 Revision 2010 Approved Mule -Hide Products Co., Inc. 1195 Prince Hall Dr Beloit, WI 53511-5481 (608) 365-3111 Ext 809 lindareith@trinityerd.com Timothy McFarland lindareith@trinityerd.com ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLI REVIEWED BY DATE 02 -®/_�� MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE CONED FASTENERS OR ATTACHMENTS ARE THE RMPOISIBILf OF THE Tim McFarland N'MUOFWOPD 1195 Prince Hall Dr Suite A Beloit, WI 535115481 (608) 365-3111 tim.mcfarland@mulehide.com THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS WHAT MAY BE NECESSARY IN ORDER TO Roofing COMPLY WITH ALL APPLICABLE CODES. Modified Bitumen Roof System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Q Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 U L LLC 08/28/2017 John W. Knezevich, PE r Validation Checklist - Hardcopy Received FL10497 R2 COI Trinity ERD CI - Nieminen - 2013.odf http://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGEVXQwtDqudsDrIH6I48wbSKANpxwHR... 2/6/2014 ,Florida Building Code Online r 2 Referenced Standard and Year (of Standard) Standard Year ASTM D6163 2000 ASTM D6164 2005 ASTM D6222 2002 FM 4470 1992 FM 4474 2004 Equivalence of Product Standards Certified By Sections from the Code x `' Product Approval Method Method 1 Option D Date Submitted 08/21/2013 Date Validated 08/28/2013 Date Pending FBC Approval 09/08/2013 Date Approved 10/18/2013 Summary of Products FL # IlModel, Number or Name Description 10497.1 Mule -Hide SBS and APP Modified i Self -adhering modified bitumen roof systems Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL10497 R2 II Al ER082113FINAL MULE - Approved for use outside HVHZ: Yes HIDE MODBIT FL10497-R2.odf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-480 Created by Independent Third Party: Yes Other: 1.) The design pressure in this application Evaluation Reports relates to one particular assembly over concrete deck. FL10497 R2 AE ER0826131FINAL MULE - Refer to the ER Appendix for other systems and deck HIDE MODBIT FL10497-R2.Ddf types. 2.) Refer to ER, Section 5 for other Limits of Use. Created by Independent Third Party: Yes Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here.. Product Approval Accepts: EL'Imck 0 sectlrit ats:'�'rLt+~�-. http://www.floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDqudsDrIH6148wb SKANpxwHR... 2/6/2014 T reasure Harvey E. Koennen C oast Professional Engineer #32831 B uilding Architect#AR0009471 E ngineers, Certified General Contractor #CGCO24776 Inc. ` . goon-1N� V INS 7205 Elyse Circle P 5 L Florida 34952-8212 PHONE(772) 466-5509 FAX(772) 489-3035 E-MAIL:hkoehnen@tcbeweb.com Contractor T.R E 65uRa -Go*k5 c zno-F%Py . ��-qj¢ Owner A NB Date lob Address 01 flxjlji�L-5S OZ. BUILT UP N1oD 61T SYSTr., iNLIP MVI-0 9LI90 '� NEW ROOF RE -ROOF_ RECOVERING REPAIR AREA 165�• f,_ - --- ---- - — --- ----- — —BUILT U-P_ROOF PLAN fps:, *.OPY NEWS . 2m�Nu MEN ASCE 7-10 & FBC 2010 ENCLOSED BLDG X SEMI ENCLOSED BLDG OPEN _ PART 2 LOW RISE C&C SIMPLIFIED RISK CAT 2/V=LCJOEXPOSU RE__Af A =1,4 Kzt =1.0/h =jjt> 1�12 PITCH/MEAN PARAPET ht= ROOF SYSTEM A I& ZONE 1 B @ h=30 = X = PSF x 0.6 = —11.40 ZONE 2 B @ h=30 = X = PSF x 0.6 = _ a = ZONE 3 B @ h=30 = X = PSF x 0.6 = a = MAX DESIGN PRESSURE PER NOA — 40 a DECK TYPE pL`WooOD THICKNESS 1,14b2.`ZAL&F- BASE SHEET 5 $S'5Q NO. OF PLIES I FnSTG IC4�&tBONDING 5¢�l' p•��-bd+P.�►.�G FASTENER SPACING FOR ANCHOR/BASE SHEET ATTACHMENT: Field I "oc @Lap, # Rows — @—"oc Perimeter- 11oc @Lap, # Rows = @='bc Corner: _ "oc@Lap, # Rows—@ oc INSULATION BASE LAYER TYPE SIZE -- Aj TYPE OF FASTENERS/OR BONDING MATERIAL J60AM FARES OR ATTACHUJIlTS INSULATION TOP LAYER TYPE SIZE ARE THE KNE91LffYY OF THE TYPE OF FASTENERS/OR BONDING MATERIAL Av,�1rOF� R0 NUMBER OF FASTENERS PER INSULATION BOARD: Field — Perimeter Corner— ��l ��1IVV�1ll f_(1WHlN! PLY SHEET NO. OF PLIES — TOP PLY SGSS-- SA NO. OF PLIES I SURFACING MI L)04LhL- DRIP EDGE SIZE 3X 3 TYPE OF FASTENERS/BONDING TYPE OF',-,&TPIE S/BONDING50L f:*APVi04NCn MATERIAL % & " &. L. T reasure C oast B uilding E ngineers, Inc. Harvey E. Koehnelr' Professional Engineer #32831 Architect #AR0009471 Certified General Contractor #CGCO24776 These tables Are For Roof eoverinas Roof coverings Installed on Buildings with a Mean Roof Height of 30' or Less Located in Exposures B, C or D Table R301.2 [2]--oF> jr( <,u;�z.3?1-5445ca 7- 1-::D COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE [PSF]. 160 Exp B 160 Exp C 160 Exp C 160 Exp D 160 Exp D (One story (Two story*) (One story") (Two story*) Roof > 0 to 7 degrees Zone 1 -27.6 -33.4 -38.7 -40.6 -45.9 7degrees = 11/2 /12 pitch Zone 2 -46.4 -56.2 -65.0 -68.3 -77.1 Zone 3 -69.8 -84.5 -97.7 -102.7 -115.9 Roof > 7 to 27 degrees -Zone 1 -25.3 - 30,7 - 35.5 -37.2 - 42 27 degrees = 6/12 pitch Zone 2 -44,1 - 63.4 - 61.8 -64.9 - 73.3 Zone 3 -65.1 -78.8 - 91.2 - 95.7 - 108:.1 Roof > 27 to 45 degrees Zone 1 - 27.8 -33.7 -40.0 -40.1 -462 45 d.egrees = 12112 pitch Zone 2 - 32.4 -39.3 -45.4 -47.7 -53.8 Zone 3 - 32.4 -39.3 -45A - 47,7 -53.8 160 Exp B 150 Exp C 150 Exp C 150 Exp D 150 Ezp D (one story*) ( two story*) (one story*) ( two story") Roof > 0 to 7 degrees Zone 1 -24.3 -29.6 -34.1 -35.8 -40.4 7degrees = 11/2 /12 pitch Zone 2 -40.8 -49A -57.2 -60.0 -67.8 Zone 3 -61.4 -74.3 -86.0 -90.3 -102,0 Roof > 7 to 27 degrees Zone 1 -22,2 - 26,9 - 31.1 -32,7 - 36.9 27 degrees = 6/12 pitch Zone 2 -38.7 - 46.9 - 542 -56.9 - 64.3 Zone 3 -57,3 - 69.4 - 80.3 -84.3 - 95.2 Roof > 27 to 45 degrees Zone 1 - 24.3 -29.5 -34.1 -35.8 -40.4 45 degrees = 12/12 pitch Zone 2 - 28.4 -34.4 -39.8 -41.8 -47.2 Zone 3 - 28.4 -34.4 -39.8 -41.8 -47.2 One story" = one story building with a maximum mean roof height of 15 feet Two story* = two story building with a maximum mean roof height of 30 feet if allowed by the Miami Dade N.O.A or Florida Product Approval ., any system -that does not meet the minimum components and cladding pressures for the area that the building is located per this form may require a Florida licensed engineer to revise the fastener spacing it T C B E, Inc. 7205 Elyse Circle PHONE (772) 466-5509 Port Saint Lucie FAX (772) 489-3035 Florida 34952-8212 E-MAIL hkoehnen@tcbeweb.com WEB SITE htto://www.tcbeweb.corr APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table 1A-1 Deck Wood Application New or Reroof (Tear -Off) 1A-2 1B Wood Wood New, Reroof (Tear -Off) or Recover New, Reroof (Tear -Off) or Recover 1C Wood New, Reroof (Tear -Off) or Recover 1D Wood New or Reroof (Tear -Off) 3E Wood New or Reroof (Tear -Off) 2A Steel or Conc. New, Reroof (Tear -Off) or Recover 2B Steel or Conc. New, Reroof (Tear -Off) or Recover 3A-1 Concrete New or Reroof (Tear -Off) 3A-2 Concrete New or Reroof (Tear -Off) 3B Concrete New or Reroof (Tear -Off) 4A LWIC New or Reroof I 4B 4C LWIC LWIC New or Reroof I New or Reroof i 5A CWF New or Reroof I 5B CWF New, Reroof (Ti 6A Gypsum New or Reroof 7A Various Recover or Recover A_2 A-2 C D E F C D A-1 A-1 F A-1 A-2 E A-1 A-2 A-1 A-1 Description Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Mech. Attached Insulation, Bonded Roof Cover Prelim. Attached Insulation, Mech. Attached Base Sheet, E Non -Insulated, Mech. Attached Base Sheet, bonded Roof i Non -Insulated, Bonded Roof Cover Mech. Attached Insulation, Bonded Roof Cover Prelim. Attached Insulation, Mech. Attached Base Sheet, E Bonded Insulation, Bonded Roof Cover Bonded Temporary Roof, Bonded Insulation, Bonded Roof Non -Insulated, Bonded Roof Cover Bonded Insulation, Bonded Roof Cover Cover TRINITY'ERD - 4 - of Cover 5 5 ded Roof Cover 6 rer 6-7 7 8 ded Roof Cover 8 9-10 ver 11 11 12 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 13 Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Coder Bonded Insulation, Bonded Roof Cover 14 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover Bonded Bonded Bonded Roof Cover Rnnded Rnnf rnuar The following notes apply to the systems outlined herein: 1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, De DuraGuard, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the QA requirements of F.A.C. Rule FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type I bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. or greater configuration to the steel and concrete deck listings. 5. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the rib the manufacturer's published instructions. ➢ HA (HA): Full coverage at 25-30 Ibs/square. ➢ Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. P. Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 1F O fi iocumented through proper codified isDeck, DensDeck Prime, DensD c ,N-3 and is documented as meetinT­,; (mechanically attached base shee 'he structural deck shall be of equal ons/beads shall expand as noted in M10000.03.08-R2 for FL10497-R2 Revision 2: 08/21/2013 Appendix 1, Page 1 of 16 TRINITY ERD - ➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. - ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ 3M CR-20: Continuous 2.5-3.5-Inch wide ribbons, 12-inch o.c. Note: 777ESET may be used where CR-20 is referenced. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one- half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to `increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed .below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-Inch thick ISO 95+ GL) ➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) 777' OPafg. ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II, Poly ISO 2) L =I' n h.➢ 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick)= 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis Is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AH], as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124. 1 12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 13. Unless otherwise noted, refer to the following references for bonded base, ply V cap sheet applications. Table 1: Mule -Hide Roof Covers i Reference Layer Materi 1 j Application SBS-SA (SBS, Self -Adhering) Base SA-SBS Base Sheet, SA-SBS Base Sheet (FR), SA Base Sheet 6163, SA Base Sheet 6163 (FR) Self -Adhering' �/ Cap � SA-SBS Cap Sheet, SA-SBS Cap Sheet (FR), SA-SBS KoolCapT , SA-SBS KooiCapT (FR) APP-SA (APP, Self -Adhering) Cap SA-APP Cap Sheet, SA-APP Cap Sheet (FR), SA-APP KoolCap—, SA-APP KoolCap'" (FR), SA-APP PF30 KoolCapT" Self -Adhering Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report M10000.03.08-R2 for FL10497-R2 Certificate of Authorizatlon #9503 Revision 2: 08121/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 16 i TRINITY' ERD - TABLE 1D: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (See Note 1) Base Sheet Roof Cover MDP (Psf) Base Fasteners Attach Ply Cap W-15 Min. 19/32-inch plywood at max. 24-inch spans attached 6-inch o.c. with #8 screws Nail Base 32 ga., 1-5/8-Inch diameter tin caps with 11 ga. annular ring shank nails. Note: Tin caps are to be primed with Mule -Hide 121 Asphalt Primer, 121 Asphalt Spray Primer orASTM D41 primer. 6-inch o.c. in 4-inch lap and 6-Inch o.c. In four, equally spaced, staggered center rows (Optional) or Base 6163 Base 6163 One more SA Sheet or SA Sheet (FR) SBS-SA or APP-SA _112.5 TABLE 1E: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System No. Deck (See Note 1) 41 Primer Roof Cover Cap MDP (Psf) joint Treatment Base Ply W-16 Min. 19/32-inch plywood at max. 24-inch spans attached 6-Inch o.c. with 8d ring shank nails (Optional) Mule -Hide 121 Asphalt Primer or 121 Asphalt Spray Primer None SBS-SA (Optional) One more SBS-SA or SBS-SA or APP-SA -90.0 V 7 Min. 15/32-inch plywood at max. t241nch s -inch o.c. 2 screws (O le -Hide 121 sphalt Primer 121 Asphalt Spray Prim is are covered with 4-inch wide strips o Base Sheet 6163 ed Into place to creat ontinuou nd. a Sheet or 5A Ba Sheet (FR) onai) Onl moreSBS-SA32-inch -orAPP-5-97.5 SBS-SA or A�A-135.0 ax. s a 6-inch o.c, p:d� with #12 screws (Optional) Mule -Hid 121 halt Primer o 21 Asp S rimer Plywood joints are cov with 4-lnch trl s of a Shee 63, rolled Into place to create continuous bon SA B heet or SA Base Sheet 6163 (FR) more SBS-SA Exterior Research and Design, LLC. d/b/a TrinityJERD Ar Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 I I Evaluation leport M10000.03.08-R2 for FL10497-112 Revision 2: 08/21/2013 Appendix 1, Page 7 of 16 TABLE ID: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF System Deck (See Note i) Base Sheet No. Ba Fasteners Attach 32 ga., 8-inch diam er tin caps with Min. 19 -' c plywood at max. 11 ga. annu ng nk nails. Note: Tin 6-Inch c. in 4-inch lap and 6-' h W-1S 24-1 spa attached 6-inch o. Nail Base caps are to be p with Mule -Hide o.c. in fou , qually spaced #8 screws sphait Pri , 121 As 'mer staggered cente or 41 primer. TABLE IE: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) . SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System No. Deck (See Note i) Primer Roof Cover Joint Treatment B se / Min. 19/32-inch plywood at max. ( al M ide 121 W-16 T 24-Inch spans attached 6-inch o.c. Asphalt 121 None" SBS-SA with 8d ring shank nails As Spray Primer Min. 1S/32-inch pl ood at ma (Optional) Mule- Plywood joi ered with 4-inch SA Base W- 24-inch spans ached 6-inch o.c. sphalt Pri r or 121 wide s of SA Base eet 6163, rolled or ase with #12 ews A halt P i J, TRINITY ERD Roof Cover P Ply Cap (Psf) (Optional) One or more SA ase Sheet 5- or _112.5 6 or SA AP A Base t 616?(FR) Ply Cap ne orTS137S-SA or APP-SA ac_cA ray r mer place to create cont in s bond. eat (FR) i /32-inch plywood at max. i al�Je-Hld Plyw oints are covered wit 4-i SA Base Sheet W-18 4-i spans attached 6-inch Asphalt wide strips o Iled 6163 or SA (Optional) On with #12 sc Asphalt Sinto place to create continuous bond. ee 163 (FR) more SBS-SA Exterior Research and Design, LLC. d/b/a Trinity]ERD Certificate of Authorization #9S03 Prepared by: Robert Nieminen, PE-59166 or APP-SA MOP (psf) -90.0 .5 I Evaluation Report M10000.03.08-R2 for FL10497-R2 Revision 2: 08/21/2013 Appendix 1, Page 7 of 16 Page 1 of 1 Se-,rt Go.,y- BUILDING & CODE SYSTEM You are logged in cocls\humphreya as: Version 21.13A t Property I Valuation t Property Alert I Edit Permit I Search Permit 1 Review I Inspection I Permit Fee/Payment I Misc Fee I Contractor I Reports I Maint I Fiscal I Post Date I Permit Status was changed to 'Issued' since Permi/2oninRenew fee has been paid AND all Reviews have been completed f Submit Query Print REVIEWS Print Review Comments Form - All com Permit # Print Review Comments Form - Non cor Enter Permit* (Press ENTER) 1312-0023 1312-0023 Email Info For Reviewer Comments PERMIT INFORMATION Permit,#: i1312;0023) Job Address: 171 PRINCESS DR Parcel #: 3419-520-0045-000/9 Master Permit it: r Permit Type: IROOF - MODIFIED BITUMEN Permit Status: jPendlng Job _ 'FT EAR_OF_AND_RE_ROOF-WITH_MODIFIED_BITt1MEN_1200-SQ-FT-2/-12-ROOF-PITCH. -- TDescription: I Date Issued: Issued By: 0 Date Finaled: 0 Finaled By: 0 REVIEWS Add Review 1 Please Select A Review to Add or View Reviewer Comments -- ............ - - - i Review Type Status i Reviewer Date Sent 'Date Started Date Comple Sent Comment Retumed Coml Date last Cha last Char _.�..-.._._..._._—.__ ............................... _........ .._._......--.....-:--._.............._.........,._.........._........__.._.:....._...__.._....._...__:..................._............._;-....._..__......__.._.._._..................................I_............._..........._._...r..._........................_......-- ..._.._._ Select To i FRONT DEANNA Edit Add Or View i Delete COUNTER ! COMPLETE GIVENSs 12/3/2013 12/3/2013 12/3/2013 I Comments REVIEW .......... ....... _.......... ........................i......_._............ ..........._................. ......... ........... ................................... _.... ........................:............. .............._!._.............................. .............._.. ........ _ ......................... ........................... ........ ' Select To ;PLANS Edit Add Or View Delete EXAMINER INCOMPLETE JOE ciao 12/3/2013 12/19/2013 12/19/2013 ( 4 12/19/2013 ddoj Comments REVIEW ' _.._...... ...................... ____.__...._...._...._.-_.._..._..._._.__...__......._._._.—._...___.._._......._._...._......_..._............._.__—__.._._.._._...... —..-.._....._................._.___.____.._..__......... _....._..........._-------- ...... _.__... _... _............ _._.._______. REVIEWER COMMENTS Add Reviewer Comments Edit first 10 Comments/Compliance Dates I Comment �mpl ante Gate Date Entered Entered Bj Date Last Changed last Changed By _ -..... _ -- -. ::: - --- There are no Review Comments listed for Wis Review. Select Review and click 'Add Reviewer Comment. http:Hcode/(Slu2oxgsscz4mdgObg5sukwm))/Add EditReview.aspx 2/4/2014 Joe Cicio From: Joe Cicio Sent: Thursday, December 19, 2013 3:33 PM To: treasurecoastllc@bellsouth.net Cc: Joe Cicio Subject: Review comments for permit # 1312-0023 Attachments: Report_FL_Review_Comments_Noncompliantjrf[l].pdf --Dear-St—Lucie-County-Permit-Applicant; --- Please see the attached plan review comments which have been generated for your permit. As soon as we receive the modified plans and any additional required documentation back from the design professional , contractor or owner we will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to permitting for permit issuance. Thank you, Josepk hc. GiCio Plans Examiner II Standard Building Inspector Building Plans Examiner One and Two TamilyDwelling Inspector One and Two TamilyPlans Examiner St. Lucie County Planning and Development Services 772-462--1553 Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. 1 6 Planning S Development. Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone4-(772)462-2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 171 Princess Dr City / Sfate /-Zip: Port-St-Lucie,—Fl- --34952-- Parcel #: 3419-520-0045-000/9 Zoning: RS-4 APPLICATION INFORMATION Permit Number: 1312-0023 Permit Type: ROOF - MODIFIED BITUMEN CONTRACTOR INFORMATION Contractor Name: Brian J Maloney Business Name: Treasure Coast Roofing Llc Business Addr: 1816 Sw Biltmore St City / State / Zip: Port St. Lucie, FI 34984 REVIEW COMMENTS Page 1 Owner(s): Amber Vinz Jurisdiction: SAINT LUCIE COUNTY Lot#: 7 Block: 137 Stories: Automatic Sprinkler System? No Fax Number: 772-343-3458 Email: Sunnyfla99@AOI.Com REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released FRONT COUNTER REVIEW COMPLETE Deanna Givens 12/3/2013 12/3/2013 12/3/2013 Comment: PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 12/19/2013 Comment: FL # 10497-R2 PRODUCT APPROVAL ONLY SUBMITTED FOR REVIEW * CONTRACTOR TO IDENTIFY WHICH SYSTEM NUMBER IS PROPOSED ' SEE NOTE #9 FOR FULLY BONDED ASSEMBLIES WHICH STATES " THE 12/19/2013 MAXIMUM DESIGN PRESSURE FOR THE SELECTED ASSEMBLY SHALL MEET OR EXCEED CRITICAL DESIGN PRESSURE IN ACCORDANCE WITH FBC CHAPTER 16 WITH NO RATIONAL ANALYSIS ALLOWED SUBMIT THE CALCULATIONS FROM FBC CHAPTER 16 WITH THE WIND SPEED AND EXPOSURE DETERMINED IN THE REPORT 12/19/2013 Comment: COMMENTS MAILED AND E-MAILED AS OF THIS DATE APPENDD( 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type St LUCIE WON BUIDINGD 1P, RAWed Not 1ka�ffip1nan� m Reviewednym �' '`�`� \` TRINITY I ER® DIeo_�.�.i4•�3 Description Page 1A-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 IA-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 1B Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 5 SC Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 6 1D Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 6-7 =1E _Wood- " _- ,� r~New-or-Reroof- Tear-0 -( ff) . F Non=Insulated; Bonded_Roof. Cover _ � 7 2A Steel or Conc. New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 8 2B Steel or Conc. New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 8 3A-1 Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 9-10 3A-2 Concrete New or Reroof (Tear -Off) A-1 Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover 11 3B Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 11 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 12 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 13 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 13 5A CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 14 56 CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 14 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 15 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 16 The following notes apply to the systems outlined herein: 1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocya nu rate, polystyrene, wood fiberboard, perlite, DensDeck, DensDeck Prime, DensDeck DuraGuard, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the QA requirements of F.A.C. Rule 9N-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System TypelD (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck.) The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. 5. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ HA (HA): Full coverage at 25-30 ibs/square. ➢ Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, SZ-inch o.c. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report M30000.03.08-R2 for FL10497-R2 Certificate of Authorization #9503 Revision 2: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of 16 I `�4 �f RI6�lIT1� I ER® D OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Notel OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. Note: 71TESET may be used where CR-20 Is referenced. D Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one- half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'Increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system In the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL) ➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II, Poly ISO 2) ➢ 3M CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance.1 A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AH], as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124. 12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 13. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. Table 1: Mule -Hide Roof Covers Reference Layer Material Application SBS-SA (SBS, Self -Adhering) Base SA-SBS Base Sheet, SA-SBS Base Sheet (FR), SA Base Sheet 6163, SA Base Sheet 6163 (FR) Self -Adhering Cap SA-SBS Cap Sheet, SA-SBS Cap Sheet (FR), SA-SBS KoolCapTM', SA-SBS KoolCapTM (FR) APP-SA (APP, Self -Adhering) Cap SA-APP Cap Sheet, SA-APP Cap Sheet (FR), SA-APP KoolCapTM', SA-APP KoolCap" (FR), SA-APP PF30 KoolCapTM' Self -Adhering Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report M10000.03.08-R2 for FL30497-112 Certificate of Authorization #9503 Revision 2: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 16 , TRINITY ! ER® 14. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Materials Directory for fire ratings associated with coating usage. ➢ Mule -Hide 102 Fibrated Roof Coating; > Mule -Hide 111 Non-Fibrated Roof Coating; > Mule -Hide 301 Emulsion Fibrated; > Mule -Hide 311 Emulsion Non-Fibrated; I > Mule -Hide 401 Premium Fibrated Aluminum Roof Coating; > Mule -Hide 406 Standard Fibrated Aluminum Roof Coating; > Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating; > Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating. Refer to current Roofing 15. The following represent priming requirements for gypsum -based coverboards: I > DensDeck and DensDeck Prime shall be field -primed with Mule -Hide 121 Asphalt Primer or 121 Asphalt Spray Primer prior to self -adhering membrane application. ➢ SECUROCK Gypsum -Fiber Roof Board or DensDeck DuraGuard do not require field priming. 16. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind loads. I Exterior Research and Design, LLC. d/b/a Trinity IERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report M10000.03.08-112 for FL10497-R2 Revision 2: 08/21/2013 Appendix 1, Page 3 of 16 TRINITY ER® TABLE 1D: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck (See Note 1) Base Sheet j Roof Cover MDP Base Fasteners Attach i Ply Cap No. (Psi 32 ga., 1-5/8-inch diameter tin caps with (Optional) One or more SA Min. 19/32-inch plywood at max. 11 ga. annular ring shank nails. Note: Tin 6-inch o.c. in 4-inch lap and 6-inch Base Sheet SBS-SA or W-15 24-inch spans attached 6-Inch o.c. Nail Base caps are to be primed with Mule -Hide 121 o.c. in four, equally spaced, 6163 or SA APP-SA -112.5 with #8 screws Asphalt Primer, 121 Asphalt Spray Primer staggered center rows Base Sheet6163 or ASTM D41 primer. (FR) TABLE 1E: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Deck (See Note 1) Primer Roof Cover MDP ]oint Treatment Base Ply Cap No. (Psf) Min. 19/32-inch plywood at max. (Optional) Mule -Hide 121 (Optional) One or W-16 24-inch spans attached 6-inch o.c. Asphalt Primer or 121 None SBS-SA SBS-SA or APP-SA -90.0 with 8d ring shank nails Asphalt Spray Primer more SBS-SA Min. 15/32-inch plywood at max. (Optional) Mule -Hide 121 Plywood joints are covered with 4-inch SA Base Sheet (Optional) One or W-17 24-inch spans attached 6-inch o.c. Asphalt Primer or 121 wide strips of SA Base Sheet 6163, rolled or SA Base more SBS-SA SBS-SA or APP-SA -97.5 with #12 screws Asphalt Spray Primer into place to create continuous bond. Sheet (FR) Min. 15/32-inch plywood at max. (Optional) Mule -Hide 121 Plywood joints are covered with 4-inch SA Base Sheet (Optional) One or W-18 24-inch spans attached 6-inch o.c. Asphalt Primer or 121 I wide strips of SA Base Sheet 6163, rolled 6163 or SA Base more SBS-SA SBS-SA or APP-SA -135.0 with #12 screws Asphalt Spray Primer into place to create continuous bond. Sheet 6163 (FR) Exterior Research and Design, LLC. d/b/a TrinityJERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report M10000.03.08-R2 for FL10497-R2 Revision 2: 08/21/2013 Appendix 1, Page 7 of 16