HomeMy WebLinkAboutSUBMITTED PAPERS\1
-�
OFFICE USE ONLY _ l:3 q ;
DATE FILED 2) 2—
PLAN REVIEW FEE: RECEIPT NO.: PERMIT NUMBER J
C.ONCURRENCY FEE: ' `" RECEIPT NO.: CERT. CAP. NO.:
ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED
PLANNING & DEVELOPMENT SERVICES DEPARTMENT
BUILDING & CODE REGULATIONS DIVI N
SCANNED 2300VirginiaAvenue
B 1 t. Pierce,. FL.34982-5652
772462-1553
St. Lucie County
APPLICATION for BUILDING PERMIT
CERTIFICATE of CAPACITY/ZONING COMPLIANCE
PROJECT INFORMATION
1. LOCATION/SI.TE ADDRESS: 4Z g,—rrzFJS &_vp. ✓L�JS
2. PROJECT NAME:Ma 4L A. -'A I A)6 L(f?'- SITE PLAN NAME: ,
3. PROPERTY TAXID#: 456 Z - Sb l - D zzy `000 -5
4. LEGALDESCRIPTION (attach extra sheets if necessary): /VET--ra< is i /,'-/L ea- IJDO
SEA oA) _ff PAV-Ce,1(-- Z
5. PLAT BOOK ! Z 6. PAGE NO. Z�?cS 7. BLOCK NO. 8. LOT NO.
9. PARCEL SIZE (ACRES/SQ FT.): % Arty LOT DRVENSIONS:
10. COMPLETE DESCRIPTION OF CONSTRUCTION PROJECTOR WORK ACTIVITY: l N'S�GL
/-iJ :544�L- At-D N G S &A-h MA_
U. SETBACKS (ACTUAL) FRONT: BACK: RIGHT SIDE: LEFT SIDE:
12. TYPE OF CONSTRUCTION (Check all appropriate boxes)
] NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ ] INTERIORRENOVATION
{4--RESIDENTIAL -1 [ ] COMMERCIAL [) INDUSTRIAL
[I OTHER (SPECIFY)
13. DESCRIPTION OF PROPOSED USE:
14. SQ. FT OF CONSTRUCTION: 15. SF. FT 1st FLOOR:....
16: VALUE OF CONSTRUCTION:
The value of construction is used to determine the.amount of permit fees to be assessed St. Lucie County reserves the right to question and/or modify the indicated
value o lion if ilia demgnstrated,thet the submitted figures are not consistent with similar types of eonstruction activities.. If the value is $2500 or more, a
RECORDED
Notice of Commencement must be submitted with this application
SLCCDV Form No.: 001-02
UPDATED 6/25109
OWNER INFORMATION
NAME: � �%! � Q iti(D � 1m1> �� n.1 f: d ! O L _S-A' 10'(2 oy—
ADDRESS: tfigggRo
CITY: 40ift (OA2CHA Qb Gi�i Q6 V) STATE: 24 1 Cy ZIP: 90@W! 3Zy
PHONE (DAYTIME): eW 7,sq - C3 92— Email: 'DAkfM09_M® ,F /a/Cl-4 • CZM
IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE
FILL IN NAME AND ADDRESS BELOW.
FEE SIMPLE TITLEHOLDER
ADDRESS:
CITY:
PHONE (DAYTIME): U
STATE:
Wr
CONTRACTOR INFORMATION ` �
ST. of FL REG.CERT # ST. LUCIE COUNTY CERT #: � V G
BUSINESS NAME: .'� VR-� �oR Sr 'i3�-6L c C
QUALIFIERS, NAME: CWQ e ( C Q.
ADDRESS: 1 ZOD 4E Gd 'r o rA 2Jr44) - U
CITY: '5tI/LiRi— STATE: * 1L ZIP: q R f
PHONE (DAYTRVIE): l l l'yl 201-q'771 FAX NO. ZZ ( —1(vI1 Email: NarJyUAkNb e-
V
ARCHIT/ENGINEML 4 eE _J�DAr" 1.1 45r
ADDRESS:
CITY:
PHONE (DAYTIME): (_) _
BONDING COMPANY: '
ADDRESS:
CITY:
MORTGAGE LENDER
ADDRESS:
STATE:
STA
rtJ
ZIP:
CITY: STATE: ZIP:
IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days after notification
it will be voided and returned to you by mail.
CERTIFICATION:
This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity,
if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all
work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits
may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS,
AND AIR CONDITIONERS, FENCES, ETC., not otherwise included with this building permit application.
St. Lucie County makes no representation that its granting of a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Homeowner Association rules, bylaws or any covenants that may restrict or prohibit such
structure. Please consult with your Homeowner's Association and review your deed for any restrictions which may apply.
The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory
structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non-
residential use.
NOTICE TO OWNER_ : YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IlVIPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOBSITE BEFORE THE
FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
NOTICE TO APPLICANT: W IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO
ATTACHMENT: AS A CONDITION OF ISSUANCE OF THIS PERMIT; YOU PROMISE IN
GOOD FAITH TO DELIVER A COPY OF THE. CONSTRUCTION LIEN LAW NOTICE TO
THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT.
STATE OF FLORID, , \ A t STATE OF FLORIDA
COUNTY OF `" COUNTY OF
The foregoing nstrument was acknowledged before
me this � day of DO_QQ-ill JLQ 20 ,
by . ✓c 0 N, I t t
who is ppyersonally _ r has produced
r D n as dentir on.
Signature 6Not
The foregoing m4rument.was acknowledged before
me this � day of �Q, UAL`Q,(2�1
by b L� (. C C �\ 1 �X, L
who is personally kn or has produced
U / r-\ . , as idenMention
Commission No. �ry Publ of Florida Commission N Notary Pubaic($8W Florida
Qly
Lucy JuNnno ' My CemWaiw FF 031228
Mmy co m1YJ lw F 081228 � w� E� 066 0001201?
NOTE: TWO �(2) D. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR
TIES BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN
THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION.
OWNER BUILDER AFFIDAVIT WILL BE REQUIRED FOR ALL OWNER/BUII.DER APPLICANTS.
For specific instructions see appropriate permit checklist.
I
BP #: 1 00 ` V
a
OFFICE USE O 1—
SECTION
TOWNSHIP
RANGE
MAP NO.
ZONING
LAND USE
-LOT CVG %
TAZ NO.
-
_
-FWOD ZONE-
- ----: -.
-FIRM-MAP #-
-, ---
---
-1ST FLR EI y
-- ---- ---
=1ViAX-HGT- -- —
_ - --
-
-. E-
CONST
- - -
OCCUP TYPE_...
_
MAX_OCCUP
# OF FIRS -
-WATER-------
- - -- -
=SEWI✓Ii - =
- -----
- - -
SPF.I�IKI EIi�
STOR1vIWATER
----=- - -
LOT OF REC
LOT OF REC
LOT SPLIT
LOT SPLIT
`Before 111990
After 111990
REQUIRED
APPROVED
REPORT
HABITABLE
RADON
PERMIT
CODE
AREA
FEE
FEE
LIBRARY
PUBLIC BID
PUBIC BID
S
IMPACT'
IMPACT FEE
MACT
IMPACT
FEE
CORRECTION
FEE
FEE
SCHOOL
ROAD
CREDIT
Y
N
LAW ENF
IMPACT
IMPACT
IMPACT
FEE
-
FEE -
FIRE/EMS
DRIVEWAY
Y
N
DRIVEWAY
ADMINISTRATIVE
-IldPACT '
REQUIRED
FEE
VARIANCE FEE
--FEE
SPECIFY
MECHANIC ROOF
NON -CONFORMING
MISCELLANEOUS
SUBS
ELECTRIC GAS
LOT OF RECORD
FEES
REQUIRED
PLUMBING
FEES
DATE SENT TO ADDRESSING: I /
REVIEWS
FRONT
CO"UNTSR .
ZONING
REVIEW
SUPERVISOR
REVIEW
PLANS
REVIEW
VEGETATION
REVIEW- -
SEA TURTLE
REVIEW
MANGROVE
REVIEW.
=DATE ,.
RECEIVED
(
1I
i(�;-y
1 L�RV -
DATE
2
OFFICE USE O , _'1p # O 2
, .�" .7
SECTION.
TOWNSHIP
RANGE
MAP NO.
ZONING,
�-
LAND USE
LOT CVG %
TAZ NO.
... .
FLOOD Z ONE.:.
IsT FIR-ELV __
_ _. _ . __-:
-MiAXHGT ..
CONST TYPE
OCCUP. TYPE .
MAX OCCUP .
_
# OF FLRS
-TER-
WA
WATER
LOT OF REC'
LOT OF RECSTORM
LOT SPLIT
LOT SPLIT
Before 111990
After 111990
REQUIRED
APPROVED
REPORT
HABITABLE
RADON
PERMIT
FEE
CODE
AREA
FEE
LIBRARY
PUBLIC BLD
PUBIC BID
ARKS
BRACT'
IMPACT FEE
IMPACT
IMPACT
FEE
CORRECTION
FEE
FEE
SCHOOL,
ROAD
CREDIT
Y
N
LAW ENF
IMPACT
IMPACT
IMPACT
.FEE.
FEE
FEE.
FIRE/EMS
--
DRIVEWAY
Y
N
DRIVEWAY
ADMINISTRATIVE
IMPACT
REQUIRED
FEE
VARIANCE FEE
:FEE
SPECIFY
MECHANIC ROOF
NON -CONFORMING
MISCELLANEOUS
SUBS
ELECTRIC GAS
LOT OF RECORD
FEES
REQUIRED
PLUMBING
FEES
DATE SENT TO ADDRESSING: 1 /
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
COUNTER.
REVMW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW.
DATE
RECEIVED
�i0�
DATE
/ 1
OMPLETEID
INITIALS
9-0
Nettles Island Inc.,: a condominium
9801 South Ocean DriVe, Jensen Beach, FL 34967
(772) 22M936
FAX (772) 2294901
November 25, 2613
Mr. David Moellering
42 Nettles Blvd
Jensen Beach, Fl 34957
RE: Dock @ Lot 42 Nettles Blvd.
Nettles Island Inc. has no objection to. the dock plans as submitted for lot 42, per the
attached, except that the dock cannot extend more than ten feet six inches (1 Oft 6in) fiom
sea wall cap. Any subsequent revisions or changes must be submitted to Nettles Island
for approval. All Nettles Island Contractor Rules and Regulations must be followed.
Nettles Island must receive the adjacent owner notice prior to construction cominencing.
Resp ctfully,
William Harkins
Operations Manager
R
A
�`�►
is er
Architectural Chairperson
ORIGINAL
PROPOSED ELEVATOR LIFTCANAL
44'WIDE
. . . . . . . . . . . . . . . . . .
MOELLERING
—j
... ... jerner.&Associatp, hic.Dater: If
42 NETTLES BLVD Endmunental Comulffig
2537.SFAVotisb Ave. PortSt. Luck, FL34952
JENSEN BEACH -}:- �_PIL(M)j83-200
]ERNEMBELLSOM.NFT
PLa---
Nettles Island Inc., a condominium
9801 South Ocean Drive, Jensen Beach, FL 34957
(772) 229-2930
FAX (772) 229-9901
November 25, 2013
Mr. David Moellering
42 Nettles Blvd
Jensen Beach, Fl 34957
RE: Dock cz Lot 42 Nettles Blvd
Nettles Island Inc. has no objection to the dock plans as submitted for lot 42, per the
attached, except that the dock cannot extend more than ten feet six inches (1 Oft bin) fiom
sea wall cap. Any subsequent revisions or changes must be submitted to Nettles Island
for approval. All Nettles Island Contractor Rules and Regulations must be followed.
Nettles Island must receive the adjacent owner notice prior to construction commencing.
PA'P4p,26
lly
,, " C 4 0 /- n
eelw
William Harkins J
Operations Manager
A
IS er
Architectural Chairperson
ORIGINAL
PROPOSED ELEVATOR LIFT CANAL
44'WIDE
. . . .
MOELLERING . . . . . .
jerner&Associatcs, Inc. Date. 11
C
42 NETTLES BLVD Emb-onmental onsulting
"I' 2537SFAyonso Am PortSt. Lck, FL34952
JENSEN BEACH Pli. M)283-2950
]ERNEMBELLSOUTUNET
afjv�
io X/ff 'ULU
Jan 17 2014 7:34AM
ISSUE DATE
PERMIT #
PLANNING & DEVELOPMENT SERVICES
Building & Code Compliance Division
BUILDING PERIIIIT
SUB -CONTRACTOR AGREEMENT
St. Lucie County Contractor Certification Number.
State of Florida Certification Number (If applicable):
Z-142� 2-
fj have agreed to be the
(Company Name/Individual Name)
Sub -contractor for 71—Q__.� k
(Type of Trade) (Primary Contractor)
For the proj ect located at RJ '/ & % p . enr ,S e.� sae. 3 y ?Jr
.(Project Street Address or property Tax ID #)
It is understood that, if there is any change of status regarding our participation with the above mentioned
project, I will immediately advise the Building and Zoning Department of St. Lucie County by filing a
Change of Sub -contractor notice. (Form: SLCCDV (No, 004-00)
BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License)
NOTARIZED SIGNATURES ARE REQUIRED
Business Name: t-- —C - k
Address: t,
City/Statelzip:
Phone:email:
SIGNATURE PRINT NAME
STATE OF FLORIDA, COUNTY OF
THE FOREGOING INSTRUMENT WAS SIGNED BEFORE ME THIS DAY OF LA -A, 1 .20 14-
BY }+�`� WHO IS PERSONALLY KNOWN OR HAS
RODUCED AS IDENTIFICATION.
(STAMP)
SIGNATURE OF NOTARY PUBLIC PRINT NAME OF NOTARY PUBLIC
SLCPDS:12f1612013
DATE
.� Notary Public State of Florida
Audra Kindet
j' My Cammisskm Er; 866382
prn0` Ewi=01121=17
JOSEPH E. SMITH, CLERK, THE CIRCUIT COURT - SAINT LUCIE COUNmv
FILE # 3917275 OR BOO=----_.D97 PAGE 601, Recorded 01/22/2014 a Z:00 PM
,l 5
Permit No. 2 L
State of Florida County of St. Lurie
NOTICE OF COMMENCEMENT
Tax Folio No.-'507- -501-OZ29- 000-5
The undersigned hereby gives notice that improvement will be made to certain real property, and In accordance with Chapter 713, Florida Statutes,
the following Information Is provided In this Notice of Commencement
Legal Description of Property: (and street address If avallab
W-frL&4 ISIAWO1106 A, cpn/Ja 56&n owJle): & . A*14!r P,WO
General description of Improvement:_ 8 D4 i `f
Owner Information or lase information If the lessee contracted for the improvement:
Name 0,W4b hMor-- W-Frjv &
Adder _ ' -" 6f 09 LVRcNAft LK
Interest in property: LVW Wb4, '-- M I CN (f� a' Name and address of fee simple titleholder (H different from Owner listed above):
ContrectoesName: Pest /Ak.
Contactor Address: 0 _ .5771,0 T K Phone Number 7e - zo I - 97 J2
Surety (if applicable, a copy of the payment band is attached): Amount of bond: S
Name and address: Phone number:
Lander Name: Phone Numb
lender's address:
Persons within the States of Florida designated by Owns u notices or other documents may be served as provided by Section
jU,y I) (a)7., Florida Statutes:
Name: Phone Number.
Address:
In addition to himself or hersNf, Owner d ates of to receive a ropy of the
Uenoes Notice as provided In Section (11(b), Florida Statutes.
Phone number of person or entity designated by owner:
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 year from the date of recording unless a different date Is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTERTHE EXPIRATION OF THE NOTICE OF COMMENCEMENTARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SHE KFCK THE FBLST
INSPECTION. IFYOU INTENDTOOBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of paqury, I declare that I have read the foregoing notice of commencement and that the facts stated therein ant true to the best of
my knowle4lie and belief.
(Signature of Owner or e, or Owners or Lessee's Man Authotactor Partner er
/ / of
0 W".1p,
(Signatory'sTI ce)
The foregoing Instrument was ac nowiedge4 before me this 1 day of 1 2(l1
By "1(.Y 1 Y �l�ts. l: �' U� for
e of Person utlarlry (e.s. officer, trustee) PartY on of hwtnemerht was ww.+»M
(Signature of N ary 1 - t Personally known produced Identification_
(Print,Type, or p one eAV 0 Type of Identificationdddddprproduced
Lucy Juliar*
yh CamilsM FF 03122e
Eypy�s py3pR017 �
STATE F FLORIDA
C-T 111Q E COUNTY
TH1
TF?�
GR
By
MIN, SETBACK REQ,
FRONT
SIDES
CNR SI
TE
CANAL
PROPOSED ELEVATOR LIFT 44,WIDE
lit_
MOELLERING }. ; �r,i�l �rAssociaccs Inc.-..� _.�_.. Date.11
42 NETTLES BLVD Ern*onmentnl Consulting
t 25375FAI onw A r. PonSt. Luck, FL34952
JENSEN BEACH PILCM)283.2950
]ERNER@BELLS0UYHA1ET
Ili
THESE PLANS AND ALL PROPOSED WORK
'ARE SUBJECT TO ANY CORRECTIONS
.REQUIRED BY FIELD INSPECTORS THAT..
:. MAY BE NECESSARY IN ORDER TO...
C®�1pLY WISH ALG�$•RPLIC�i®LE CO�E�;
Nettles Island Inc., ca condominium
9801 South Ocean Drive, Jensen Beach, FL 34957
(772) 229-2930
FAX (772) 229-9901
November 25, 2013
Mr. David Moellering
42 Nettles Blvd
Jensen Beach, Fl 34957
RE: Dock @ Lot 42 Nettles Blvd
Nettles Island Inc. has no objection to the dock plans as submitted for lot 42, per the
attached, except that the dock cannot extend more than ten feet six inches (1 Oft 6in) from
sea wall cap. Any subsequent revisions or changes must be submitted to Nettles Island
for approval. All Nettles Island Contractor Rules and Regulations must be followed.
Nettles Island must receive the adjacent owner notice prior to construction commencing.
R,esp ctfully, / o V
/��Gdiul G�22'%y��Gh• ��Jl / G c1/�
William Harkins J
Operations Manager
� is er
Architectural Chairperson
ORIGINAL
` HURRICANE BOAT LIFTS
11►� 'il
10
Uft
2 Cradles
per lift
2 Tracks
per IHl
Bunk
Cable
�^'^^�
Track
Gut
E.B.D.
not Pit.
H.S.
U.H.S.X2
Cop.
I -Beam
Size
I -Beam
Size
Boards
Size
Spread
Poet
Height
Gear
Molar H.P.
Gear
Motor H.P.
Gear
Motor H.P.
Cear
Motor H.P.
3,000/
8, 1"^1y�0�
4•N
22258/.19
ong
4N
3/4HP
3/4HP
3/4 H.P.
1 H.P.
Wr Fr.
Wf Fr.
2'x8'xl2'
0
5,D00/
N OW
.3123
B- Lo
a
8H DIN
z.33//23
x .
2-5/16'
3/4HP
3/4HP
3/4 H.P.
1 H.P.
6.1617
WAIN FT.
O a.181/
WrILIN Fr.x30'
Pressure
Treated
S.S.
60'
4,125
x.41%.25
7,000/
6'-4' LL7.02
y/9
7.023
W
Ir 25' 3/
1.
Carpeted
2 Part
3/4HP
3/4HP
3/4 H.P.
1 H.P.
IUN
Wr UN
2-3/8•
cc
viix
x.44 37
x
x.14 27
10,000#
6'-4 Long
O B.360�
x 2 '
O 8.36
x30' S.S.
3/4HP
3/4HP
3/4 H.P.
1 H.P.
WT0/
UN
WT UN FFfT
2 Part
x
X.
w.41 25
x.41 /.23
3 z10 x14
12,000/
long
w 2Y.2
Pr sour*
Treated
2-3/B'
1HP
114P
1HP
1/2 H.P
Wr UNS
ear 11N }T.
Carpeted
x45S.S.
12
120'
15.0001
w
long
x
„�52D
1 1/2 H.P
010.266
Dig -zee
3'xlo'x16'
3 Port
Pressure
N A
/
1HP
1HP
4 29
47�. D
17,000/
101/Lon
011.672
x 25�
011.672/
Treated
Duly
1 1/2 H.P
WT UN
WT UN FT
Carpetod
o,
20000{'
x . 7W
00' Lagrq
21b, W
x 25'
2-3/8•
x60' S.S.
N/A
1HP
-
TIUN FT
0/4.292/
WTN Fi
4 Part
PILING MOUNT
BRACKET DETAIL
Mount Bracket To Piling,
Uee (2) 3/4- Stoinleae Steel
Wedge Anchors
Through Bracket Into Concrete
Bracket
SEAWALL MOUNT
Mount Bracket to Dock DOCK MOUNT
Use (2) 3/4' Stainless Steel
Thru. Bolts
MOUNT BRACKET DETAIL
THE WORK SPECIFIED HEREIN HAS BEEN DESIGNED & ALL WORK SHALL BE IN ACCORDANCE WITH STRUCTURAL PROVISIONS OF THE 2010 FLORIDA BUILDING, CODE.
NOTE
THIS UFTING STRUCTURE HAS BEEN DESIGNED TO WITHSTAND WIND LOADS ASSOCIATED WITH WIND SPEEDS OF V,A - 180 MPH, V= - 139 MPH (3 SEC. GUST) EXPOSURE 'D'
WITHOUT A BOAT ON THE LIFT PER ASCE 7-10 USING ABOVE GROUND SIGN/WALL METHOD, THE LIFTING STRUCTURE INCLUDING BOAT WAS BEEN DESIGNED TO WITHSTAND WIND
SPEEDS OF V,A -90 MPH IN EXPOSURE 'C' OR 80 MPH IN EXPOSURE V.
OWNER RESPONSIBLE TO REMOVE BOAT FROM UFT DURING WINDSTORM EVENT IN EXCESS Vood AS CALATED BELOW, PER FBC 3105.5.3 STRUCTURES DESIGNED TO BE READILY
REMOVED OR REPOSITIONED DURNING PERIODS OF HIGH WIND VELOCITY SHALL BE POSTED WITH A LEGIBLE AND READILY VISIBLE DECAL. OR PAINTED INSTRUCTIONS TO BE THE
OWNER OR TENANT TO REMOVE OR REPOSITION THE STRUCTURE OR PART THEREOF DURNING SUCH PERIODS OF TIME AS ARE DESIGNATED BY THE U.S. WEATHER BUREAU AS
BEING A HURRICANE WARNING OR ALERT. THE LIFT OWNER SHALL BE NOTIFIED OF THESE CONDITIONS BY THE PERMIT HOLDER. NO WARRANTY, EXPRESSED OR IMPLIED, IS
CONTAINED HEREIN. Vaed MAY BE CALCULATED BY THE FOLLOWING FORMULA: Vaed - J 0.6 • Vult. DESIGN OF BOAT WIND LOADING HAS BEEN PERFORMED WITH THE FOLLOWING
RATIOS AS CONFIRMED BY OTHERS: B/s-3, s/h - 0.75, FOR A Of of 1.6 MAXIMUM WHERE H IS THE HEIGHT TO TOP OF BOAT, B IS HORIZONTAL DIMENSION, AND S IS VERTICAL
DIMENSION. '
CERTIFICATION OF BOAT LIFT TO EXISTING STRUCTURE AND ALL ELECTRICAL OR MECHANICAL CERTIFICATIONS ARE BY OTHERS; ENGINEER SEAL CERTIFIES ASSEMBLY OF LIFT
ONLY.
THIS DETAIL IS PREPARED AS A GENERAL NON -SITE SPECIFIC MASTER PLAN SHEET DETAIL TYPICAL FIELD CONDITIONS ARE ASSUMED IN THE DESIGN. WOOD PILES SHALL BE
SEASONED WOOD WITH G-0.55 OR BETTER. SHOULD ANY SPECIFIC LOCATION DIFFER FROM THAT SPECIFIED HEREIN, OR STANDARD FIELD CONDITIONS, ADDITIONAL SPECIFIC
ENGINEERING MAY BE REQUIRED AS DETERMINED BY THE BUILDING INSPECTOR AND PERMITTING CONTRACTOR. CARE SHALL BE TAKEN BY CONTRACTOR IN ALL APPLICATIONS OF
THIS DETAIL AS THIS 15 NOT A SITE SPECIFIC DRAWING, IT IS THE RESPONSIBILITY OF OTHERS TO ENSURE THE INTEGRITY OF INSTALLATION TO THE HOST STRUCTURE.
ALUMINUM
MATERIAL' 6061 T6 ALUMINUM
ALL WELDS ARE MIN. 1/4' FULL FILLET WELD USING 5556 FILLER ALLOY. ALL WELDING MUST CONFORM TO AISC STEEL CONSTRUCTION MANUAL 13TH ED AS INSPECTED AND
VERIFIED BY OTHERS.THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALUMINUM MEMBERS FROM DISSIMILAR METALS TO PREVENT ELECTROLYSIS.
FASTENERS
ALL ANCHORS TO BE HILTI BRAND OR MFR EQUIVALENT. ALL BOLTS SHALL BE HOT DIPPED GALVANIZED, OR STAINLESS STEEL & MEET THE REQUIREMENTS OF ASTM A304 WITH
HARDENED WASHERS AND HEX NUTS. WASHERS SHALL BE USED BETWEEN WOOD & BOLT HEAD & BETWEEN WOOD & NUr. WHERE GENERIC FASTENERS ARE LABELED IN DETAILS,
CAPACITIES SHALL BE EQUAL TO OR GREATER THAN HILTI KWIK BOLT II OR RED HEAD 7HRU BOLTS. EMBEDMENT DEPTHS SPECIFIED HEREIN ARE DEPTHS INTO SOLID SUBSTRATE
AND DO NOT INCLUDE THICKNESS OF STUCCO OR OTHER FINISHES.
ALUMINUM MEMBERS IN CONTACT WITH CONCRETE AND WOOD SHALL BE PROTECTED BY "KOPPERS BITUMINOUS PAINT' OR POLYETHYLENE TAPE UHMW (ULTRA HIGH MOLECULAR
WEIGHT) 11.7 mile (0.30 mm) MIN. TOTAL THICKNESS IN ACCORDANCE WITH CURRENT FLORIDA BUILDING CODE. ALL WELDS PER FLORIDA BUILDING CODE.
B&B CONSULTING ENGINEERS,INC. HAS NOT VISITED THIS JOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIED DATA AND MEASUREMENTS. B&B
CONSULTING ENGINEERS,INC. SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. WORK SHALL BE VERIFIED
PRIOR TO CONSTRUCTION.
B&B CONSULTING ENGINEERS,INC. SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO
MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS.
ENGINEERING SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, eL al. INDEMNIFIES & SAVES
HARMLESS THIS ENGINEER FOR ALL COSTS & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION. SYSTEM ERECTION & CONSTRUCTION
PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FORM DEVIATIONS OF THIS PLAN, EXCEPT IS EXPRESSLY PROVIDED IN HEREIN, NO
CERTIFICATION OR AFFIRMATIONS ARE INTENDED. Oscar M. Bermud z PE. DATE:
HURRICANE BOAT LIFTS
Reg. Florida No. 8141
3301 S.E. Slater Street
Stuart; Florida 34997 B&B Engineers,
(772)-781-2556 706 S. 7th STREET
Fax ar
(71-4854
erwFT. PIERCE, FLORIDA 3495
s: n/11/13 n/15 W s?o:sr,alore u.'r ro axara[ a ,ee tsc -
0
- - MOELLERING
42 NETTLES BLVD
JENSEN BEACH
Jerner & Associates, Inc. -
_. Environmental Consulting
2537 SE Alfonso Ave. Port St. Ludy FL 34952
I— --1
Ph(772)283-2950
JERNEWBELLSOUTH.NET
Sheet 1
Date: 11114113 1 - -
Gi
M
0
24'
WILL NOT BE CONNECTED
TO SEAWALL CAP
SEE LIFT SPECIFICATIONS
FOR WINDLOAD AND
STRUCTURAL DETAILS
i
of
i
50' SHORELINE
...... ...... ...... _.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._..�
1 16'
Q\��S
00
10 _
CANAL
PROPOSED ELEVATOR LIFT---""I
IFT 44' WIDE
MOELLERING
42 NETTLES BLVD
JENSEN BEACH
Jeraer & Associates, Inc.
Environmental Consulting
i
2537 SE Alfonso Ave. Port St. Lucie; FL 34952
C— — — Ph(772)283-2950
JERNER@BELLSOLITH.NET
1 " = 10'
Sheet 2
Date: 11114113
r
Florida Department of Environmental Protection
Bob Martinez Center
2600 Blair Stone Road
Tallahassee, Florida 32399-2400
SELF CERTIFI� 5TION FOR THE ADDITION OF A BOAT LIFT TO
PRIVATE, RESIDENTIAL SINGLE-FAMILY DOCK
Self Certification File No.: 0322501001EE
File Name: 42 Nettles Blvd Jensen Beach, FL 34957
- Self Certification Boat Lift (Aquatic Preserves)
Rick Scott
Governor
Herschel T. Vinyard Jr.
Secretary
Dear BRUCE JERNER: On, 11/14/2013, you used the Department's electronic Self Certification Process to
certify compliance with the terms and conditions necessary for the addition of a Boat Lift to a private,
residential single-family dock at a detached, single-family residence located at:
LAT - Degrees: 27 Minutes: 17 Seconds: 7.6751
LONG - Degrees: -80 Minutes: 13 Seconds: 37.7728
SITE ADDRESS: 42 Nettles Blvd Jensen Beach, FL 34957
COUNTY: St. Lucie
For:
DAVID MOELLERING
42 NETTLES BLVD
Jensen Beach, FL 34957
You have certified that the Boat Lift you propose to construct at the above location meets all the conditions
of the Self Certification Process. A Boat Lift that is built in conformance to those conditions (attached for
reference) will:
1. Qualify for a regulatory exemption under Chapter 18-20.004(5)(b)8 of the Florida Statutes. As such, it is
exempt from the need to obtain a DEP Environmental Resource Permit.
Your Self Certification is based solely on the information you provided under this process, and applies only
to the statutes and rules in effect when your certification was completed. The certification is effective only
for the specific Boat Lift proposed, and only if the Boat Lift is constructed, operated, and maintained in
conformance with all the terms, conditions, and limitations stated in the Self Certification Process. In
addition, any substantial modifications in your plans should be submitted to the Department for review, as
changes may result in a permit being required.
You have acknowledged that this Self Certification will automatically expire if
1. Construction of the Boat Lift is not completed within one year from the self certification date;
2. site conditions materially change;
3. the terms, conditions, and limitations of the Self Certification are not followed; or
4. the governing statutes or rules are amended before construction of the project.
Completion of the Self Certification constitutes your authorization for Department personnel to enter the
property for purposes of inspecting for compliance.
Receipt of this Self Certification constitutes letter of consent required by rule 18-21.004(7) F.A.C.
ADDITIONAL INFORMATION
This Self Certification Process does not relieve you from the responsibility of obtaining other permits or
authorizations from other agencies (federal, state, Water Management District, or local) that may be required
for the project. Construction of the Boat Lift may require federal authorization. The Corps has been furnished
a copy of your Self Certification letter. They will contact you with further information about their process. If
you do not hear from them, please contact them directly. Jacksonville District contact information can be
found at; http://www.saj.usace.army.mil/Missions/Regulatory.aspx. Failure to obtain all applicable
authorizations prior to construction of the Boat Lift may result in enforcement.
If you have any questions, please contact your local Department District Office. Contact information can be
found at`. http://www.dep.state.R.us/water/wetlands/docs/sler_contacts.pdf. When referring to your project,
please use the Self Certification file number listed above.
Sincerely,
Florida Department of Environmental Protection
Enclosures:
Single Family Dock Criteria
General Conditions for Soverignty/State-Owned Submerged Lands Authorization
Manatee ' Conditions
Boat lifts are subject to all of the following conditions:
1. Is to be installed in an existing slip or, at or adjacent to the waterward end of the dock;
2. With other mooring will not result in the mooring of more than two vessels (including jet skis);
3. Will be built without adding new surface area to the dock such as walkways, gangplanks, or catwalks;
4. Will not be located in areas prohibited for mooring by a previously issued permit or other form of
authorization issued by a local government;
5. Will not substantially impede the flow of water, cause water pollution, or create a navigational hazard;
6. Is used ONLY for recreational, noncommercial activities associated with the mooring or storage of
boats and boat paraphernalia;
7. Cannot be placed in waters that are deeper than -4 ft MLW;
8. Will accommodate the proposed boat use in order to ensure that a minimum of one foot clearance is
provided between the deepest draft of a vessel and the top of any submerged resources at mean or
ordinary low water;
I
9. The dock, together with the boat lift, cannot extend waterward more than 500 feet or more than 20% of
the width of waterbody (or 25% in Boca Ciega Bay or Pinellas County Aquatic Preserves), whichever
is,less; and
10. Mooring areas cannot be enclosed in whole or in part with walls, doors, screens or any other materials.
General Conditions for Soverignty/State-Owned Submerged Lands Authorization
Any use of, sovereignty/state-owned submerged lands is subject to the following general conditions that are
binding upon the applicant and are enforceable under Chapters 253 or 258, F.S.:
1. Sovereignty/state-owned submerged lands may be used only for the specified activity or use. Any
unauthorized deviation from the specified activity or use and the conditions for undertaking that
activity or use will constitute a violation. Violation of the authorization will result in suspension or
revocation of the applicant's use of the sovereignty/state-owned submerged lands unless cured to the
satisfaction of the Board of Trustees of the Internal Improvement Trust Fund (Board).
2. Authorization under Rule 18-21.005, F.A.C., conveys no title to sovereignty/state-owned submerged
lands or water column, nor does it constitute recognition or acknowledgment of any other person's title
to such land or water.
3. Authorizations under Rule 18-21.005, F.A.C., may be modified, suspended or revoked in accordance
with its terms or the remedies provided in Sections 253.04, F.S. or Chapter 18-14, F.A.C.
4. Structures or activities will be constructed and used to avoid or minimize adverse impacts to resources.
5. Construction, use, or operation of the structure or activity will not adversely affect any species which is
endangered, threatened or of special concern, as listed in Rules 68A-27.003, 68A-27.004, and
68A,27.005, F.A.C.
6. Structures or activities will not unreasonably interfere with riparian rights. When a court of competent
jurisdiction determines that riparian rights have been unlawfully affected, the structure or activity will
be modified in accordance with the court's decision.
7. Structures or activities will not create a navigational hazard.
8. Structures will be maintained in a functional condition and will be repaired or removed if they become
dilapidated to such an extent that they are no longer functional.
9. Structures or activities will be constructed, operated, and maintained solely for water dependent
purposes.
10. The applicant agrees to indemnify, defend and hold harmless the Board and the State of Florida from
all claims, actions, lawsuits and demands in any form arising out of the authorization to use
sovereignty/state-owned submerged lands or the applicant's use and construction of structures on
sovereignty/state-owned submerged lands. This duty to indemnify and hold harmless will include any
and all liabilities that are associated with the structure or activity including special assessments or taxes
that are now or in the future assessed against the structure or activity during the period of the
authorization.
11. Failure by the Board to enforce any violation of the authorization or waiver by the Board of any
provision of the authorization will not invalidate the provision not enforced or waived, nor will the
failure or waiver prevent the Board from enforcing the waived or unenforced provision in the event of
a future violation of that provision.
12. Applicant binds itself and its successors and assigns to abide by the provisions and conditions set forth
in! the authorization. If the applicant or its successors or assigns fails or refuses to comply with the
provisions and conditions of the authorization, the authorization may be terminated by the Board after
written notice to the applicant or its successors or assigns. Upon receipt of such notice, the applicant or
its successors or assigns will have thirty (30) days in which to correct the violations. Failure to correct
the violations within this period will result in the automatic revocation of this authorization.
13. All costs incurred by the Board in enforcing the terms and conditions of the authorization will be paid
by the applicant. Any notice required by law will be made by certified mail at the address shown on
pages one of the authorization. The applicant will notify the Board in writing of any change of address
at least ten days before the change becomes effective.
14. This authorization does not allow any activity prohibited in a conservation easement or restrictive
covenant of record that prohibits the activity.
Manatee Conditions
The following conditions are intended to protect manatees from direct project effects; THESE CONDITIONS
APPLY ONLY IN WATERS THAT ARE ACCESSIBLE TO MANATEES:
1. All personnel associated with the project will be instructed about the presence of manatees and
manatee speed zones, and the need to avoid collisions with and injury to manatees. The permittee will
advise all construction personnel that there are civil and criminal penalties for harming, harassing, or
killing manatees which are protected under the Marine Mammal Protection Act, the Endangered
Species Act, and the Florida Manatee Sanctuary Act.
2. All vessels associated with the construction project will operate at "Idle Speed/No Wake" at all times
while in the immediate area and while in water where the draft of the vessel provides less than a
four -'foot clearance from the bottom. All vessels will follow routes of deep water whenever possible.
3. Siltation or turbidity barriers will be made of material in which manatees cannot become entangled,
will be properly secured, and will be regularly monitored to avoid manatee entanglement or
entrapment. Barriers must not impede manatee movement.
4. All on -site project personnel are responsible for observing water -related activities for the presence of
manatee(s). All in -water operations, including vessels, must be shutdown if a manatee(s) comes within
50 feet of the operation. Activities will not resume until the manatee(s) has moved beyond the 50-foot
radius of the project operation, or until 30 minutes elapses if the manatee(s) has not reappeared within
50 feet of the operation. Animals must not be herded away or harassed into leaving.
5. Any collision with or injury to a manatee will be reported immediately to the FWC Hotline at
1-888-404-FWCC. Collision and/or injury should also be reported to the U.S. Fish and Wildlife
Service in Jacksonville (1-904-731-3336) for north Florida or Vero Beach (1-772-562-3909) for south
Florida.
6. Temporary signs concerning manatees will be posted prior to and during all in -water project activities.
All signs are to be removed by the permittee upon completion of the project. Awareness signs that have
already been approved for this use by the Florida Fish and Wildlife Conservation Commission (FWC)
must be used (see MyFWC.com). One sign which reads Caution: Boaters must be posted. A second
sign measuring at least 8 1/2" by 11" explaining the requirements for "Idle Speed/No Wake" and the
shut down of in -water operations must be posted in a location prominently visible to all personnel
engaged in water -related activities.
�gECttO!!
�-R
Florida Department of Environmental Protection
Bob Martinez Center
2600 Blair Stone Road
Tallahassee, Florida 32399-2400
FEDERAL SPGP SELF CERTIFICATION FOR
A PROJECT AT A PRIVATE, SINGLE-FAMILY RESIDENCE
Self Certification File No.: 0322501001EE
File Name:, 42 Nettles Blvd Jensen Beach, FL 34957
- Self Certification Boat Lift (Aquatic Preserves)
Rick Scott
Governor
Herschet T. Vinyard Jr.
Secretary
Dear BRUCE JERNER: On, 11/14/2013, you used the Florida Department of Environmental Protection's
electronic Self Certification Process to certify compliance with the terms and conditions of the Federal State
Programmatic General Permit (SPGP) Self Certification Process for a project at private, single-family
residence located at:
LAT - Degrees: 27 Minutes: 17 Seconds: 7.6751
LONG - Degrees: -80 Minutes: 13 Seconds: 37.7728
SITE ADDRESS: 42 Nettles Blvd Jensen Beach, FL 34957
COUNTY: St. Lucie
For:
DAVID MOELLERING
42 NETTLES BLVD Jensen Beach, FL 34957
You have certified that the project you propose to construct at the above location meets all the conditions of
the SPGP Self Certification Process and will be built in conformance to those conditions (attached for
reference). Your proposed activity as certified is in compliance with the SPGP program. U.S. Army Corps of
Engineers (Corps) Specific conditions apply to your project, attached. No further permitting for this
activity is required by the Corps. In the event of the transfer of ownership of the property by sale or by any
other means, when the structures or work authorized by this SPGP Self Certification are still in existence at
the time ,the property is transferred, the terms and conditions of this SPGP Self Certification will continue to
be binding on the new owner(s)of the property. Although the construction period for works authorized by
Department of the Army permits is finite, the permit itself, with its limitations, does not expire. To
validate the transfer of this SPGP Self Certification and the associated responsibilities associated with
compliance with its terms and conditions, the attached transfer of SPGP Self Certification request must be
completed and submitted to the Department at the time of transfer of ownership. The address is given below
on the attached transfer form.
This SPGP Self Certification is based solely on the information you provided under this process, and applies
only to the statutes and rules in effect when your certification was completed. You have recognized that your
{ 1 )
certification is effective only for the specific project proposed, and provided the project is constructed,
operated, and maintained in conformance with all the terms, conditions, and limitations stated in the SPGP
Self Certification Process. This Self Certification will not apply if any substantial modifications are made to
the project. You agree to contact the Department for review of any plans to construct additional structures or
to modify the project, as changes may result in a permit being required.
You have acknowledged that this Self Certification will automatically expire if:
1. construction of the project is not completed by midnight, July 25, 2016, unless construction commenced
or a contract to construct was executed before July 25, 2016, in which case the time limit for completing the
work authorized by the SPGP ends at midnight, July 25, 2017. However, in no case can construction continue
for more than one year beyond the Self -Certification date;
2. site conditions materially change;
3. the terms, conditions, and limitations of the Self Certification are not followed; or
4. the governing statutes or rules are amended before construction of the project.
Completion of the Self Certification constitutes your authorization for Department or Corps personnel to
enter the property for purposes of inspecting for compliance.
This Self Certification Process does not relieve you from the responsibility of obtaining other permits or
authorizations from other agencies (federal, state, or local) that may be required for the project. Failure to
obtain all applicable authorizations prior to construction of the project may result in enforcement.
If you have any questions, please contact your local Department District Office. Contact information can be
found at: http://www.dep.state.R.us/water/wetlands/dots/sler_contacts.pdf. For further information, contact
the Corps directly at: http://www.saj.usace.army.mil/Missions/Regulatory.aspx. When referring to your
project, please use the SPGP Self Certification file number listed above.
Authority for review - an agreement with the U.S. Army Corps of Engineers entitled Coordination
Agreement, between the U. S. Army Corps of Engineers (Jacksonville District) and the Florida Department of
Environmental Protection State Programmatic General Permit, Section 10 of the Rivers and Harbor Act of
1899 and Section 404 of the Clean Water Act".
Enclosures:
General Conditions
Further Information
Manatee Conditions
Submerged Aquatic Vegetation Conditions
Marsh and Mangroves Conditions
Sea Turtle and Smalltooth Sawfish Construction Conditions
CONDITIONS FOR DEPARTMENT OF THE ARMY SELF CERTIFIED STATE
PROGRAMMATIC
GENERAL PERMIT FOR A PROJECT AT A PRIVATE, SINGLE-FAMILY RESIDENCE
General Conditions:
1. The time limit for completing the work authorized by the SPGP ends at midnight, July 25, 2016, unless
construction commenced or a contract to construct was executed before July 25, 2016, in which case
the time limit for completing the work authorized by the SPGP ends at midnight, July 25, 2017.
However, in no case can construction continue for more than one year beyond the Self -Certification
date.
2. I must maintain the activity authorized by this pennit in good condition and in conformance with the
terms and conditions of this permit. I am not relieved of this requirement if I abandon the permitted
activity, although I may make a good faith transfer to a third party in compliance with General
Condition 4 below. Should I wish to cease to maintain the authorized activity or should I desire to
abandon it without a good faith transfer, I must obtain a modification of this permit from this office,
which may require restoration of the area.
3. If I discover any previously unknown historic or archeological remains while accomplishing the
activity authorized by this permit, I must immediately notify this office of what I have found. We will
initiate the Federal and State coordination required to determine if the remains warrant a recovery
effort or if the site is eligible for listing in the National Register of Historic Places.
4. If I sell the property associated with this permit, I must obtain the signature and mailing address of the
new owner in the space provided in the permit and forward a copy of the permit to this office to
validate the transfer of this authorization.
5. If a conditioned water quality certification has been issued for my project, I must comply with the
conditions specified in the certification as special conditions to this permit.
6. I must allow representatives from this office to inspect the authorized activity at any time deemed
necessary to ensure that it is being or has been accomplished in accordance with the terms and
conditions of my permit.
7. The permittee understands and agrees that, if future operations by the United States require the
removal, relocation, or other alteration, of the structures or work herein authorized, or if, in the opinion
of the Secretary of the Army or his authorized representative, said structure or work will cause
unreasonable obstruction to the free navigation of the navigable waters, the permittee will be required,
upon due notice from the Corps of Engineers, to remove, relocate, or alter the structural work or
obstructions caused thereby, without expense to the United States. No claim will be made against the
United States on account of any such removal or alteration.
Further Information:
1. Limits of this authorization.
1. This permit does not obviate the need to obtain other Federal, State, or local authorizations
required by law.
2. This permit does not grant any property rights or exclusive privileges.
3. This permit does not authorize any injury to the property or rights of others.
4. This permit does not authorize interference with any existing or proposed Federal projects.
2. Limits of Federal Liability. In issuing this permit, the Federal Government does not assume any
liability for the following:
1.. Damages to the permitted project or uses thereof as a result of other permitted or unpermitted
activities or from natural causes.
2. Damages to the permitted project or uses thereof as a result of current or future activities
-undertaken -by -or-on -behalf -of fihe Umited -States, -in the publicinterest.
3. Damages to persons, property, or to other permitted or unpermitted activities or structures caused
by the activity authorized by this permit.
4: Design or construction deficiencies associated with the permitted work.
5. Damage claims associated with any future modification, suspension, or revocation of this permit.
3. Reliance on Applicant's Data: The determination of this office that issuance of this permit is not
contrary to the public interest was made in reliance on the information I provided.
4. Reevaluation of Permit Decision: This office may reevaluate its decision on this permit at any time the
circumstances warrant. Circumstances that could require a reevaluation include, but are not limited to,
the following:
1. I fail to comply with the terms and conditions of this permit.
2. The information provided by me in support of my permit application proves to have been false,
incomplete, or inaccurate (see 3 above).
I Significant new information surfaces which this office did not consider in reaching the original
public interest decision.
5. Such a reevaluation may result in a determination that it is appropriate to use the suspension,
modification, and revocation procedures contained in 33 CFR 325.7 or enforcement procedures such as
those contained in 33 CFR 326.4 and 326.5. The referenced enforcement procedures provide for the
issuance of an administrative order requiring I comply with the terms and conditions of my permit and
for the initiation of legal action where appropriate. I will be required to pay for any corrective measures
ordered -by this -off ee, -and if I fail ,to-.eomply •with such•directive-, this affice ,May .in -•certain- situations
(such as those specified in 33 CFR 209.170) accomplish the corrective measures by contract or
otherwise and bill me for the cost.
6. When the structures or work authorized by this permit are still in existence at the time the property is
transferred, the terms and conditions of this permit will continue to be binding on the new owner(s) of
the property. To validate the transfer of`this permit and the associated -liabilities associated with
compliance with its terms and conditions, have the transferee sign and date the transfer form attached
to the permit.
Manatee Conditions:
1. All personnel associated with the project will be instructed about the presence of manatees and
manatee speed zones, and the need to avoid collisions with and injury to manatees. The permittee will
advise all construction personnel that there are civil and criminal penalties for harming, harassing, or
killing manatees which are protected under the Marine Mammal Protection Act, the Endangered
Species Act, and the Florida Manatee Sanctuary Act.
2. All vessels associated with the construction project will operate at "Idle Speed/No Wake" at all times
while in the immediate area and while in water where the draft of the vessel provides less than a
four -foot clearance from the bottom. All vessels will follow routes of deep water whenever possible.
3. -Sfhatian-art-urbidity barriers will be made -of rnater-ial in which m anatees- vannot become -entangled,
will be properly secured, and will be regularly monitored to avoid manatee entanglement or
entrapment. Barriers must not impede manatee movement.
4. All on -site project personnel are responsible for observing water -related activities for the presence of
manatee(s). All in -water operations, including vessels, must be shutdown if a manatee(s) comes within
50 feet of the operation. Activities will not resume until the manatee(g) has moved beyond the 50-foot
radius of the project operation, or until 30 minutes elapses if the manatee(s) has not reappeared within
50 feet of the operation. Animals must not be herded away or harassed into leaving.
5. Any collision with or injury to a manatee will be reported immediately to the FWC Hotline at
1-888-404-FWCC. Collision and/or injur,y should also be reported to the U.S. Fish and Wildlife
Service in Jacksonville (1-904-731-3336) for north Florida or Vero Beach (1-772-562-3909) for south
Florida.
6. Temporary signs concerning manatees will be posted prior to and during all in -water project activities.
All signs are to be removed by the permittee upon completion of the project. Awareness signs that have
ne c y.l en- pl owed fgr.this u se: by ft. Flarida fishgiRd V�i�tdl fe. C.o4w4t � Cam,�inim FWD)
must be used (see MyFWC.com). One sign which reads Caution: Boaters must be posted. A second
sign measuring at least 8 1/2" by 11" explaining the requirements for "Idle Speed/No Wake" and the
shut down of in -water operations must be posted in a location prominently visible to all personnel
engaged in water -related activities.
Submerged Aquatic Vegetation Conditions:
1. Avoidance. The piling -supported structure will be aligned so as to minimize the size of the footprint
over SAV beds.
2. The height of piling -supported structure will be a minimum of 5 feet above MHW/OHW as measured
from the top surface of the decking.
3. The width of the piling -supported structure is limited to a maximum of 4 feet. A turnaround area is
allowed for piling -supported structures greater than 200 feet in length. The turnaround is limited to a
section of the piling -supported structure no more than '10 feet in length and no more than 6 `feet in
width. The turnaround will be located at the midpoint of the piling -supported structure.
4. Over-SAV bed portions of the piling -supported structure will be oriented in a north -south orientation to
the maximum extent that is practicable.
5. Terminal Platforms:
1. If possible, terminal platforms will be placed in deep water, waterward of SAV beds or in an area
devoid of SAV beds.
2. If a terminal platform is placed over SAV areas and constructed of grated decking, the total size
-of -the platform -will be limited -to if 0-square feet. The grated -deck material will -eenfor-m to -the
specifications stipulated below. The configuration of the platform will be a maximum of 8 feet
by 20 feet. A minimum of 5 feet by 20 feet will conform to the 5-foot height requirement; a 3
feet by 20 feet section may be placed 3 feet above MHW to facilitate boat access. The long axis
of the platform should be aligned in a north -south direction to the maximum extent that is
practicable.
3. If the terminal platform is placed over SAV areas and constructed of planks, the total size of the
platform will be limited to 120 square feet. The configuration of the platform will be a maximum
of 6 feet by 20 feet of which a minimum 4-foot wide by 20-foot long section will conform to the
5-foot height requirement. A section may be placed 3 feet above MHW to facilitate boat access.
The 3 feet above MHW section will be cantilevered. The long axis of the platform should be
aligned in a north -south direction to the maximum extent that is practicable. If the 3 feet above
MHW section is constructed with grating material, it may be 3 feet wide.
6. Pilings will be installed in a manner which will not result in the formation of sedimentary deposits
("donuts" or "halos") around the newly installed pilings. Pile driving is the preferred method of
installation, but jetting with a low pressure pump may be used.
7. The spacing of pilings through SAV beds will be a minimum of 10 feet on center.
8. The gaps between deckboards will be a minimum of 1/2 inch.
Marsh and Mangroves Conditions:
Marsh:
1. The piling -supported structure will be aligned so as to have the smallest over -marsh footprint as
practicable.
2. The over -marsh portion of the piling -supported will be elevated to at least 4 feet above the marsh floor.
3. The width of the piling -supported is limited to a maximum of 4 feet. Any exceptions to the width must
be accompanied by an equal increase in height requirement.
Mangroves:
1. The width of the piling -supported structure is limited to a maximum of 4 feet.
2. Mangrove clearing is restricted to the width of the piling -supported structure.
3. The location .and .alignment .of .the. piling -supported structure. should he through .the. narrowest .area _of
the mangrove fringe.
Sea Turtle and Smalltooth Sawfish Construction Conditions
The permittee will comply with the following protected species construction conditions:
1. The permittee will instruct all personnel associated with the project of the potential presence of these
species and the need to avoid collisions with sea turtles and smalltooth sawfish. All construction
personnel are responsible for observing water -related activities for the presence of these species.
2. The permittee will advise all construction personnel that there are civil -and criminal penalties for
harming, harassing, 'or killing sea turtles or smalltooth sawfish, which are protected under the
Endangered Species Act of 1973.
3. Siltation barriers will be made of material in which a sea turtle or smalltooth sawfish cannot become
entangled, be properly secured, and be regularly monitored to avoid protected species entrapment.
Barriers may not block sea turtle or smalltooth sawfish entry to or exit from designated critical habitat
without prior agreement from the National Marine Fisheries Service's Protected Resources Division,
St. Petersburg, Florida.
4. All vessels associated with the construction project will operate at "no wake/idle" speeds at all times
while in the construction area and while in water depths where the draft of the vessel provides less than
a four -foot clearance from the bottom. All vessels will preferentially follow deep -water routes (e.g.,
marked channels) whenever possible.
5. If a sea turtle or smalltooth sawfish is seen within 100 yards of the active daily construction/dredging
operation or vessel movement, all appropriate precautions will be implemented to ensure its protection.
11 pag_.f mq ._ � z gfaa cpj..
sea turtle or smalltooth sawfish. Operation of any mechanical construction equipment will cease
immediately if a sea turtle or smalltooth sawfish is seen within a 50-ft radius of the equipment.
Activities may not resume until the protected species has departed the project area of its own volition.
6. Any collision with and/or injury to a sea turtle or smalltooth sawfish will be reported immediately to
National Marie Fisheries -Service's ProtcW Res� Dtvmon {727-824-531.2) and the local
authorized sea turtle stranding/rescue organization.
7. Any special construction conditions, required of your specific project, outside these general conditions,
if applicable, will be addressed in the primary consultation.