HomeMy WebLinkAboutSUBMITTED PAPERSi
2013-12-04 20:0�3 ''.a tayly ` roofing 772 468 8397 7724621735 P 4/7
DATE: EES DUE: RECEIPT #: Permit #:
�., Planning & Development Services Department
4 Building & Codc Regulation Division SQA/V/VE4)
o r 23OU Virginia Avcnac g Y
Ft.'Pierce, FL 34982.56SZ St � UC
'Tel. 772-4624553 �� �pU�fy
APPLICATION FOR ROOF PERMIT
SEE EVER6E BIDE FO INSiR QiIQNS
1. Location %Site Address: '
2. Parcel ID Number: I
I
3. Description of Project or Work Activity: �p,rY qlp yG��
4. Total Roof Area (square feet): r 5. Roof Pifftch: Z2 -Y^ ;
6. Type of Roof: [ Fiberallass Shingle [ J Concrete Roof Tile [ ] Wood Shake / Shingle
( J Tarim& Gravel [ ] Modified Bitumen Other
[� I
[ v�roduct Approval required for all types of Roofing Material (2 Sets) Mfg_ Al 1Weis
5
[ J All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553. 4 VY1 be required.
7. Owner information �� Ch ' Contractor Information
8.
Name: I n 4 A43 k P 11—ri 1 Ce FL Reg/Cert #:
Address:. q1 I tl fe� tl Avg-, County Cert#:
City: - State: ic, Business Name:; . '
Zi I PvY Iid&
p• Phone: Phone:
I
9. Value of Construction: SZ, J
6*Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval,
CONTRACTORIOWNER'S AFFIDAVIT: I certify tha All o the information contained in this application is correct and that all work will be
done in co ' phi cc With all applicable luws regulating construction and zoning.
PRINT Q IALIPERS/OWNERS NAME SIG ATURE OF QUALIFIEWOWNER
STATE OF FLORIDA. COUNTY OF
I ,
ACKNOWLEDGED BEFORE ME THIS DAY OF
�$;IGNATU
P ONA L gpowN TO ME OR HAS PRODUCED
AS IDENTIFICATION
NOTARY PUIILIC-S7 NI'g OF FLORIDA
I E F' NOTARY TYPE OR PRINT NAME OR NOTARY "�j��jf",• Karen S. Nielsen
(sea[) `Commisslon#01000358
COMMISSION NUMBER '•, ,, Expires; JUNE 12, 2014
DONDEDTiuIU ATLWrICDONDUiOCC vggt
NOTICE To OWNER; FAILURE To RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY,,, IF YOU INTEND TO OBTAIN FINANCING. CONSULT YOUR LENDER OR -
ATTORNEY, BEFORE itECOR1)ING YOUR NOTICE OF COMMENCEMENT.
I
RcvbW 4612010
I
i
I
I
I
I
2013-12-04 20:03 j.a.tay'; roofing 772 468 8397 5 7724621735 P 5/7
- 've-oky ^NMraroor-1Wr,r.uwro WWW114y, 1-4` 11Qpk1Iwww.I w§1U jJC51tJ111matip rprQ1IQ= I,U 1013U'I'I'I000U
PROPERTY RECORD CARD
IC1•nncth I, \lr)lultcul Rrrnrd:I ut.I h-iraryrunnk I'rrnul� 111am 1-ruU
111nllotl hil-nulu•u11u
Site Addruss:
5915 Deleon Ave
SelYl'um tinge;
12134S :398
Map ID:
13/12N
Zoning: I
RS-4
l
11w11crship :Ind : 11101n"-
Parccl lU: 1301-613.0111.000.0
Mow 4: 3221
ylClE�
Usc'I'ypc; SF Ro
6 :•
Cily/Cnty: Saint Luck County
OwniT; Kenneth L McMuIlcn Mildred F McMulicn
. Addrow 591S Deleon Ave
FortPico c FL 34951
Impl Ue.enpliarl
LAKSW00D PARK -UNIT I I- BLK 142 LOT 4 (MAP 13112N) (OR 3562-
2430)
tinlr:. IIII In11111 ir-11
ksusi menI ;hl,i
Dato
Pries
Code
Deed
Book/Pusc
2013 Final:
38900
9/17/2013
1 58500
0001
WD
3562 / 2430
Assessed:
38900
7/611992
39S00
00
WD
0798 / 2285
AS.Cmdit.
0
Z124/1992
100
01
PR
0779 / 0092
lixampt:
10/10/1991
100
01
PR
076611440
Taxable:
I
Texts:
787.81
W111.17I.NG
INI-1.1101ATION
'Intel Land and Ruildinai
Lund Value; $400 A4aet: 0.24
Building Valuc: 33500
Finisbcd Arch: 1032 SgFt
I:�ler•u�r 1•r:uu14-, 1
Vices: -
RoolCover:
TO - Tar & Gravel
Rou4Strnet;
GA - Cubic
tatt'rypc; HD - HD
Y0131t;
1972
Framo:
Grado: D - D
Ellyrult:
1977
PrimcWnll;
DS - CB Stuao
Sturyl•1ght; i 0010. 1 Story
No,Unila;
1
scCW1111.
1111r-1',br 1.4-1111111`"
mR<wms; 3
Meade:
MX - MAXIMUM
PrmintWall:
PF - PF
PuIlBlnh; 1
Hc;lt'I'ypc;
PHA -MdHotAir
&SRUPI:
STD
1/213tith: 1
AixltFucl:
9L8C - Electric
Prm'Flors;
CU - Curpct
%A/C: 100
%Heat&
100
%Sprinktud:
0
Special brawre%ant1 VAId Ilan%
1,9111110ormatims
Typo I Y/S (Ay,
Unils Quul, Cund,
W131t, No. userypo
.11ype
Mom= Dupilr
SUSF . SITE DEV S-F Y 1
1 AV AV
2001 1 0100SF Res
91-Front Ft
100 105
THIS INFORMATION IS BELIEVED TO 6E CORRECT AT THIS TIME BUT 1T 15 SUBJECT TO CHANGE AND IS
NOT WARRANTED,
I
i
I
Page 1 of 1
L
DATE: FEES DUE: RECEIPT #: Permit #:
�s Planning & Development Services Department
.�.; Building & Code Regulation Division
2300 Virginia Avenue
Ft. Pierce, FL 34982-5652
Tel. 772-462-1553
APPLICATION FOR ROOF PERMIT
i SEE EVERSE SIDE FOR INSTRUCTIONS
1. Location/Site Address: �.17 LZe � nl 11 UE
2. Parcel ID Number: f , 10 /�. (1 1 f • (160.
Office Use
Only
ownship
Range
Map Page
Zift fl
LAiW Use
I I ' ' 1
3. Description; of Project or Work Activity:
4. Total Roof Area (square feet): ,G � f6 5. Roof Pitch:
6. Type of Roof: [vfFiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle
[ ] Tar & Gravel [ ] Modified Bitumen [V� Other I
[ �ro'duct Approval required for all types of Roofing Material (2 Sets) metlal� e S
z•�;
[ ] All 'Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: 1&nP j&,Cd FL Reg/Cert #: 0j CC 13 , 5 $qTj
Address: AVC County Cert #:
City:I?,,& VC E State: Business Name: � '
i
Zip: Phone: �, % /o �J��% 1 Phone: qta&1110!, Q
9. Value of Construction: $a.°O
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify th all o the information contained in this application is correct and that all work will be
done in co' pli ce with all applicable laws regulating construction and zoning.
� r •.
r W
PRINT Q ALIFIERS/OWNERS NAME ` SI ATURE OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY OF lE
ACKNOWLEDGED BEFORE ME THIS DAY OF 20� , BY
i
WHO IS P 7NA L OWN TO ME OR HAS PRODUCED AS IDENTIFICATION
NOTARY PUBLIC -STATE OF FLORIDA
SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY (seal) Karen S. Nielsen
- , =Commission#DD1000358
COMMISSION NUMBER 4 )� 1 OO� ��X Expires: JITNE 12, 2014
t BONDED TIIRU ATLANTIC BONDING CO., INC.
I
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNT'V
FILE 1) 3903921 OR BOOK 4 PAGE 2032, Recorded 12/05/2013 al :14 AM
NOTICE OF COMMENCEMENT M
TO RE COMPLETED WHEN CONSTRUCTION VALUE EXCEEDS S2,SW.00 3
OR WHEN HEATING OR AIR CONDITIONING REPAIR OR REPLACEMENT EXCEEDS 47,500.00 {i
PERMIT ii: TAX FOLIO is t 3D I 'CPI 3 (3111
Sloto of Florida, County of slptj(A um the undersigned hereby gives notice that Improvement will be made to certain f real property, and In accordance with chapter 713, Florida statutes, the following Information I$ provided In this notice of �Commencement. I
1. LEGAL DESCRIPTION OF PROPERTY (AND STREET ADDRESS IF AVAILABLE): 5q I5 bF-LE0i i �lE.
1 �4x wooer PH-,?-K 0 n I + I I tIbIK IL!'- L.ot y
2. GENERAL DESCRIPTION OF IMPROVEMENT:
3. QOWNER INFORMATION or [--]LESSEE INFORMATION (H Lessee contracted for the Improvement)
a. Name: K>=-N me mU u li
Address: 591 1��>`�oN �a1E.I Re NA rI�RCE, 'j�951
b. Interest in proper y: Owner
I c. Name and address o fee simple title holder (if other than owner):
4. CONTRACTOR:
a. Name: J. A. TAYLOR ROOFING, INC.
Address: 302 MELTON DRIVE, FORT PIERCE, FL 34982
b. Phone number: 772-466-4040
5, SURETY COMPANY (IF Applicable, a copy of the payment bond Is attached):
a. Name & Address:_N/A
b. Phone number: Bond amount:
6. LENDER/MORTGAGE COMPANY:
a. Name & Address: N/A
b. Phone number:
7. PERSONS WITHIN THE STATE OF FLORIDA DESIGNATED BY OWNER UPON WHOM NOTICES OR OTHER DOCUMENTS MAY BE
SERVED AS PROVIDED BY SECTION 713.13 (1) (a) 7., FLORIDA STATUTES:
a. Narne & Address: _N/A
b. Phone number: tax number:
8. IN ADDITION TO HIMSELF OR HERSELF,
a. Owner designates _N//l of to
receive a copy of the Ilenor's notice as provided In section 713.13(1)(b), Florida statues.
b. Phone number:
9. EXPIRATION DATE OF NOTICE OF COMMENCEMENT:
(THE EXPIRATION DATE IS ONE 11) YEAR FROM THE DATE OF RECORDING UNLESS A DIFFERENT DATE IS SPECIFIED).
WARNING IQ OWNER,
ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION Of THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPIM PAYMENTS UNDER CHAPTER 713,
PART I, SECTION 713.13, FLORIDA STATUTES AND CAN RESULT W YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
'MUST BE RECORDED AND POSTED ON ME JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULTwrin YOUR LENDER OR AN
ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
UNDER PENALTIES OF PERJURY. I DECLARE THAT I HAVE READ THE FOREGOING AND THAT THE FACTS IN IT ARE TRUE TO THE BEST OF MY
KNO EDGE AND BELIEF TION 92.525. FLORIDA STATUTES
II , NATURE OF OWNER or LESSEE of OWNER'S AUTHORIZED OFFICER/DIRECTOR/PARTNER/MANAGER - SIGNAOR 'S TITLE / OFFICE
THE FOOR,EGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS �-DAY OF_AQ, 20�, BY:
- .. J
AS[CjP}� FOR
NAME OF PERSON TYPE OF AUTHORITY NAME OF PARTY ON BEHALF Of WHOM INSTRUMENT WAS EXECUTED
❑i ERSONALLY KNOWN OR ❑PRODUCED I NTIFICATION TYPE OF IDENTIFICATION PRODUCED
Tt��SIGNA�RE
/NOTARY PRINTED NAME /NOTARY SEAL
NOTARY PUBLIC -STATE OF FLORIDA
Karen S. Nielsen
`.Coili #DD1000358
•`Expires; JUNE 12, 2014
BONDED TILRU ATLANTIC DONDINo Co, INC,
STATE OF FLORIDA
ST. LUCIE COUNTY
THIS IS TO CERTIFY THATTHIS IS A
TRUE AND CORRECT COPY OF THE
ORIGiIM.
JCS PH E. SMITH, GLERK
By:
M
Property Appraiser - St.Lucie County, FL
Kenneth L McMullen
Record: I of I
Property Identificalion
Site Address:
5915 Deleon Ave
Sec/Town/Range:
12 :34S :39E
Map ID:
13/12N
Zoning:
RS4
I
Ownership and ;Mailing
http://www.pasic.o�� -`;Islc/prc.asp?prclid=130161301110000
i
PROPERTY RECORD CARD
<<Prcv Next>> Spec.Assmnt Taxes T;xcmphons Permits Home Print
CO
PatcellD:
1301-613-0111-000-0
Account #:
3221
Use Type:
City/Cnty:
SF Res
Saint Lucie County
�•�' „_: ,..
..
Owner: Kenneth L McMullen Mildred F McMullen
Address: 5915 Deleon Ave
Fort Pierce FL 34951
Sales Infornuttion
Date
Price'
Code
9/17/2013
58500
0001
7/6/1992
3.9500
00
2/24/1992
100
01
10/10/1991
100
01
Legal Descriplion
LAKEWOOD PARK -UNIT I I- BLK 142 LOT 4 (MAP 13/12N) (OR 3562-
2430)
Assessment 2013
Deed
Book/Page
2013 Final:
38900
WD
3562 / 2430
Assessed:
38900
WD
0798 / 2285
Ag.Credit:
0
PR
0779 / 0092
Exempt:
PR
0766 / 1440
Taxable:
'faxes:
787.81
BUILDING
Total Land and Building
Land Value: 5400 Acres: 0.24
Building Value: 33500
Finished Area: 1032 SgFt
Exterior features
View:
-
RoolCover:
TG - Tar & Gravel
RoolStruct:
GA - Gable
ExtType:
HD - HD
YearBlt:
1972
Frame:
-
Grade:
D - D
E11YrBlt:
1977
Primewall:
BS - CB Stucco
StoryHght:
0010 - 1 Story
No. Units:
1
SecWall:
-
Interior Fealures
BedRooms:
3
Electric:
MX - MAXIMUM
PrmIntWell:
PF - PF
FullBath:
1
HeatType:
FHA - FrcdHotAir
AvgHt/Fl:
STD
1/213ath:
1
lieatf uel:
ELEC - Electric
Prm.Flors:
CU - Carpet
100
%Heated:
100
%Sprinkled:
0
Special Features and Yard
Items
Land Information
Type i
Y/S Qty.
Units Qual. Cond.
YIBlt. No. Use Type
Type
Measure Depth
SDSF — SITE DEV S-F i
Y 1
1 AV AV
2001 1 0100-SF Res
BI -Front Ft
100 105
THIS INFORMAI ION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
Page 1 of 1
2013-12-18 13:34 j.a.taylw' �)ofing 772 468 8347 >> 7724626443 P 1/1
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-2165 or 772-462-2172
Fax: 772-462-6443
ROOF INSPECTION AFFIDAVIT
I
Re: Permit # •
name & circle license type)
licensed as a ntractor" ngineer/Architect
*5 ul ingInspector
'Gene'ral, BuUding, Resldentlal or Roofing Contractor or any Individual certified under 468 F.S. to make such an Inspection.
On or about I did personally inspect the roof deck nailiUg
(Date)
work at; '� q L5It�an��i�k. 1 _ J. �
(job site address)
Based upon that examination I have determined the installation was done according to the Hurricane
Miti ration Retrofit Manual (Based on 553.844 F.S.)
Signature and Seal License #
STATE OF FLORID
COUNTY OF =- j,LL(-
Swor to nd subscribed before me thisA
� da� of - 20�
by Wers�pfially known to me or who has produced
as Identification,
Notary Public, State of Flo da ,
Signature of Nof� v -�
Commission Number: (Seal)
NOTARY PUBLIC.STM OF FLORIDA
En 01/L9/2011 •"""". Karen S. Nielsen
Gi�mrrission �`ll.D1000358
ExpLres: ,TUNE 12, 2014
aoNIAW Tuao 479.ANTIc HONDlNc c0.,>NQ
RECEIVED DEC, 18 2013
T reasure
Harvey E. Km'�
C oast
Professional Li 6rri2er #32831
B uilding
Architect #AR0009471
E ngineers,
Certified General Contractor #CGCO24776
Inc.
7205 Elyse Circle
P S L Florida 34952-821'
PHONE(772) 466-5509
FAX(772)489-3035
E-MAIL:hkoehnpn@tcbeweb.com
I
Contractor TA.-ILOe Owner M c, M U LL5-14 Date 17-A 1
Job Address Sal D���>r� N ,.Vg
METAL ROOFING X >eTArc. _ s Sy
NEW ROOF RE -ROOF_ REPAIR AREA 2101
METAL ROOF PLAN
SEEM
■
■ME
M
ME
�
■
MINE
■■■■■■■■■■■■■■■■■■�n■■n
�
...
gym■■■■■■■■■■■
■■■■■MEMM
n■■■■■■m�
■
■■■■■IEEE
■■■■■■■■■■■■e����Bm
■ni
ASCE 7-10 & FBC 2610 ENCLOSED BLDG X SEMI ENCLOSED BLDG OPEN '.
i
PART 2 LOW RISE C&C SIMPLIFIED
RISK CAT 2/V EXPOSURE_t?:, X = 1,0 Kzt =1.0/h 1 b / _1 /12 PITCH
ROOF SYSTEM V V w-� r-i- 14&4s,2.
ZONE 1 P @ @ h=30 = X = PSF x 0.6 = —2?!0 itit '
ZONE 2 P @ _ @ h=30 = X PSF x 0.6 = --4e- 4" a = `_
ZONE 3 P @ @ h=30 = X = PSF x 0.6
MAX DESIGN PRESSURE PER NOA " '7epq @ 15",;. �•
DECK TYPE pL IWOo' THICKNESS LV32"?AtM,
BASE SHEET W 1F ?.-5 NO. OF PLIES I FAST :TY E PAeffic-- SoL.Is flF1 Eptaa-• ��^ 4-1�S"
PLY SHEET NO. OF PLIES - FASTENER TYPE - SPACING
TOP PLY �� NO. OF PLIES FASTENER TYPE SPACING -'
INSULATION BASE LAYER TYPE SIZE
TYPE OF FASTENERS: SPACING FIELD PERIMETER CORNERS
INSULATION TOP LAYER TYPE SIZE
TYPE OF FASTENERS/ 10^ l4 w000yt.(tOmw 5 04a- JA vo ►.SHOT-S
DRIP EDGE SIZE sX S�. DRIP MATERIAL06,4A4•G FLASHING MATERIAL 24d.P,4.1• -
FASTENER SPACING FOR METAL ROOF PANELS: FIELD 15` PERIMETER 1 y " CORNER 0 5.. A?
0
i
T reasure Harvey E. Koehnen
toast Professional Engineer #32831
B uilding Architect #AR0009471
E ngineers, Certified General Contractor #CGCO24776
Inc.
These tables Are For Roof Coverings
Roof coverings Installed on Buildings with a
Mean Roof Height of 30' or Less Located in Exposures B, C or D
Table R301.2 [2]_9 F►c�uP-�-T
3�ns5-( A5cIE 7- iv
COMPONENTS AND CLADDING WORST CASE
DESIGN PRESSURE [PSFJ
i
160 Exp B 160 Exp C
160 Exp C 160 Exp D 160 Exp D
(One story
(Two story*) (One story") (Two story
Roof > 0 to 7 degrees Zone 1 -27.6 -33.4
-38.7 -40.6 -45.9
7degrees = 11/2 /12 pitch Zone 2 -46.4 -56.2
-65.0 -68.3 -77.1
Zone 3 -69.8 -84.5
-97.7 -102.7 -115.9
Roof > 7 to 27 degrees
'Zone 1
-25.3
27 degrees = 6/12 pitch
Zone 2
-44.1
Zone 3
-65.1
i
Roof > 27 to 45 degrees
Zone 1
- 27.8
45 degrees = 12/12 pitch
Zone 2
- 32.4
I
Zone 3
- 32.4
150 Exp B
Roof > 0 to 7 degrees Zone 1 -24.3
7degrees = 11/2 /12 pitch Zone 2 -40.8
Zone 3 -61.4
Roof > 7 to 27 degrees Zone 1 -22.2
27 degrees = 6/12 pitch Zone 2 -38.7
I Zone 3 . -57,3
- 30.7
- 35.5
-37.2
- 42
- 63.4
- 61.8
-64.9
- 73.3
-78.8
- 91.2
- 95.7
- 108-:.1
-33.7
-40.0
-40.1
-46:2
-39.3
-45.4
-47.7
-53.8
-39.3
-45.4
- 47.7
-53.8
it
150 Exp C 150 Exp C 150 Exp D 150 Exp D
(one story*) (two story*) (one story*) ( two story)
-29.6 -34.1 -35.8 -40.4
-49A -57.2 -60.0 -67.8 C1-
-74.3 -86.0 -90.3 -102.0 I
- 26.9 - 31.1 -32.7 - 36.9
- 46.9 - 54.2 -56.9 - 84.3 1�I
- 69.44 - 80.3 -84.3 - 95.2
Roof > 27 to 45 degrees Zone 1 - 24.8 -29.5 -34.1 -85.8 -40.4
45 degrees = 12/12 pitch Zone 2 - 28.4 -34.4 -39.8 -41.8 -47.2
Zone 3 - 28.4 -34.4 -39.8 -41.8 -47.2
I
One story* = one story building with a maximum mean roof height of 15 feet
Two story* = two story building with a maximum mean roof height of 30 feet
I
If allowed by the Miami Dade N.O.A or Florida Product Approval ., any system.that does. not meet the
minimum components and cladding pressures for the area that the building is located per this form
may require a Florida licensed engineer to revise the fastener spacing
i
T C B E, Inc. 7205 Elyse Circle PHONE (772) 466-5509
Port Saint Lucie FAX (772) 489-3035
Florida 34952-8212 E-MAIL hkoehnen@tcbeweb.com
WEB SITE htto://www.tcbeweb.com
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
`26 GA. 5V-CRIMP PANEL'
FLORIDA PRODUCT APPROVAL
FL 14645.2-11I
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3"d Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4290
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (918) 493-3568 �11�
I
1
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
Report No. C1800-27 OF ttu�
Date: 12.9.11 �� STATE •; UI,.
♦ Q . 00 Ft
��;• �2♦
\2 t-��
Manufacturer:
Product Name:
Panel Description:
Materials:
Deck Description:
Deck Attachment:
Underlayment:
I
Slope:
FL 14645.2-R1
C 1800-27
12.9.11
Page 2 of 3
Metal Sales Manufacturing Corporation
✓5V-Crimp
24" wide coverage with (5) 1/2" high ribs
Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
✓Min. 15/32" thick plywood for new and existing constructions.
Designed and installed as per FBC 2010.
8d x 2.5" long ring shank nails or 48 x 2" long wood screws @ 6" o.c.
in the plywood field and edges
Minimum underlayment as per FBC 2010 Section 1507.4.5
✓1/2:12 or greater in accordance with FBC 2010 Section 1507.4.2
Design Uplift Pressure: 58.5 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2) �%16.7 psf @ fastener spacing of 15" o.c.
Panel Attachment:
Type: #9-16 or 410-14 hex head wood screws with sealed washer. Fastener
shall be of su fcient length to penetrate through the deck a minimum
of 3/8".
At panel ends ✓ @ 6" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with UL580-94 (Rev 98) `Uplift
Resistance of Roof Assemblies' and TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2010 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2010 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. The design uplift pressure for reduced support spacing may
be computed using rational analysis prepared by a Florida Professional
Engineer. This evaluation report is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2010 Section 1505 and current
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
PANEL OVERLAP
5V-CRIMP FASTENER AT PANEL FLAT
SEE DETAIL 3 SEE DETAIL _REQUIRED FOR PANEL
—--- ENDS ONLY.
PLYWOOD J
15/32" THICK (MIN.)
8d x 2.5" LONG RING SHANK NAIL
OR #8 x 2" LONG WOOD SCREWS
SPACED ® 6" O.C. IN THE FIELD &
AT PLYWOOD EDGES
UNDERLAYME14T SHALL BE INSTALLED MIN. 2X- WOOD RAFTER/JOIST/
AS PER MANUFACTURER'S INSTALLATION TRUSS AT MAX. 24" O.C.
GUIDELINES TYPICAL PANEL INSTALLATION X-SECTION
WITH OR SEALING WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 24" O.C.
DETAIL 1
#9-16 OR #10-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 24" O.C.
"�" "" D ETAI L 2
5V-CRIMP
MIN 26 GA.
-YWOOD
15/32" THICK (MIN.)
5V-CRIMP
AIN 26 GA.
YWOOD
15/32" THICK (MIN.)
PANEL OVERLAP
PANEL FASTENER PER ALLOWABLE
PRESSURE TABLE ON THIS SHEET.
3" FROM PANEL ENDS.
ALLOWABLE UPLIFT PRESSURE
FASTENER PRESSURE
SPACING (PSF)
(IN)
24 58.5
15 76.7
GENERAL NOTES*
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.017"). EFFECTIVE COVERING
WIDTH OF PANEL = 24".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4 REQUIREPANEL SYSTEMMAYWINDLOADS
BEEIINSTALLEDBWHEN THEI"ED FOR EACH REQU RED DESIGN WECT. THIS
ND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE. -THE CODE SHALL CONTROL.
6 S AS
REQUIREDOREACH
RAFTERS/JOISTS/TRUSSES
AND ARE THE RESPONSIBILITY THSTAND "
PONSBIILITYOF OTHERS.
n:
z t:N
7
V)0 0
U � �
ya in Y I
� owe
)
N
N
00
Ln
uS
A
w a
_
ou
IL x
o
a
W
o:
a
�
.
i
xn
g
1 OF 1
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
�—� 353 CHRISTIAN STREET, UNIT #13
TRINITY I ERD OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
Carlisle Coatings & Waterproofing Evaluation Report C39180.12.11-112
900 Hensley Lane FL6785-R5
Wylie, TX 75098 Date of Issuance: 12/09/2011
Revision 2: 10/12/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed, by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: CCW Roof Underlayments
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUiED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes; the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to; the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be (done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request Hof the Building Official. `V
This Evaluation Report consists of pages 1 through 4. 1�
Prepared by:
v?
The facsimile seal appearing was authorized
E_;� •�, r`' by Robert Nleminen, P.E. on 10/12/2012
This does not serve as an electronically signed
Robert J.M. Nieminen, P.E. %Fs ; document. signed, sealed handcopApproval A have been
�, •_,����� .±���°;.•``� transmitted to the Product Approval Administrator and
Florida Registration No. 59166, Florida DCA ANE1983 to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
I
i
fRINITYERD
ROOFING !COMPONENT EVALUATION:
1. SCOPE:
Product Category:
Roofing
Sub -Category: Underlayment
Compliance Statement: CCW Roof Underlayments, as produced by Carlisle Coatings & Waterproofing,
have demonstrated compliance
with the following
sections of the Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions
of Use set forth herein.
2. STANDARDS:
Section
Property
Standard Year
2001
1567.2.4, 1507.2.9.2,
Physical Properties
ASTM D1970
1507.5.3
3. REFERENCES:
Entity
ERD (TST6049)
Examination
Physical Properties
Reference Date
C41280.10.12 10/05/2012/2011
MTI (TST2508)
Physical Properties
PX02MOA O1/101/17/2011
MTI (TST2508)
Physical Properties
PXI6MOA
PX13MOB 01/18/2011
MTI (TST2508)
M-D (CER1592)
Physical Properties
HVHZ Compliance
09-0630.13 08/12/2009
ICC-ES (EVL2396)
2009 IBC Compliance
ESR-1556 03/01/2012
03/01/2012
ICC-ES (EVL2396)
2006 IBC Compliance
ESR-2206
UL, LLC. (QUA9625)
Quality Control
TGDY.R18678 Listing 10/18/2010
Uli LLC. (QUA9625)
Quality Control
Inspection Report, R18678 02/20/2012
4. PRODUCT DESCRIPTION:
14.11 CCW WIP 100 is a self -adhering, fiberglass reinforced, granule surfaced, rubberized asphalt
roof underlayment.
4.12 CCW WIP 250 is a self -adhering, fiberglass reinforced, film surfaced, rubberized asphalt roof
n er rayment.
4.3 CCW WIP 300HT is a self -adhering, coated- polyolefin-composite film surfaced, rubberized
asphalt roof underlayment.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
512 Fire Classification is not part of this report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.3 CCW Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to
the AHJ for approval based on this evaluation combined with supporting data for the prepared
roof covering.
Exterior Research and Design, LLC. Evaluation Report C39180.12.11-R2
FL6785-R5
Certificate of Authorization #9503
Revision 2: 10/12/2012
Page 2 of 4
i
5.41
I
5.5
1
5.5.1
TRINITY ERD
Allowable roof covers applied atop the underlayments are follows:
Table 1: Roof Cover Options
Underlayment
Asphalt
Shingles
Nail -On Tile
Foam -On
Tile
Metal
Wood
Shakes &
Shingles
Slate &
Synthetic
Slate/Shake
CCW WIP 100
Yes
No
No
No
No
No
CCW WIP 250
Yes
No
No
Yes
No
No
CCW WIP 300HT
Yes
No
No
Yes
No
Yes
Allowable substrates are noted below:
Direct -Bond to Deck:
Self -adhering membranes applied to:
New untreated plywood;
Primed new untreated plywood;
Existing plywood;
Primed existing plywood;
Note: While not required, CCW-702 or CAV-GRIP primer may be
appropriate or when temperatures are below 40°F.
used when deemed
5.5.2 Bond to Mechanically Attached Base Laver:
Self -adhering membranes applied to:
I
ASTM D226, Type I or II felt;
For installations under mechanically attached prepared roof coverings, base layer shall be
attached per minimum codified requirements.
5.6 Exposure Limitations:
5.6.1 CCW WIP 100, CCW WIP 250 and CCW WIP 300HT shall not be left exposed for longer than
30-days after installation.
6. INSTALLATION:
61.1 CCW Roof Underlayments shall be installed in accordance with Carlisle Coatings &
Waterproofing published installation requirements subject to the Limitations set forth in
Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the
substrate thoroughly to remove any dust and debris prior to application. Prime the substrate
(if applicable) with CCW-702 or CAV-GRIP Primer.
6.3 CCW WIP 100 CCW WIP 250 and CCW WIP 300HT:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC
Sections 1507 for the type of prepared roof covering to be installed.
6.3.2 While not required, CCW-702 or CAV-GRIP primer may be used when deemed appropriate.
Priming is required when temperatures are below 40°F.
6.3.3 Cut WIP roofing underlayment into 10 to 15 ft lengths. Remove 2 to 3 ft of release film and
align the edge of the membrane, sticky -side down, so it overhangs the drip edge by 3/8-inch.
Continue to remove release film and press as you move across the roof. Use a hand roller
and/or hand pressure to press into place.
Exterior Research and Design, LLC. Evaluation Report C39180.12.11-R2
Certificate of Authorization #9503 FL6785-R5
Revision 2: 10/12/2012
Page 3 of 4
TRINITY ERD
6.3.4 Horizontal seams should be minimum 3.5-inches, configured to shed water. Vertical seams
should be 6-inches and staggered not less than 2-ft from vertical seams in the course below.
6.3.5 Consult Carlisle Coatings & Waterproofing for steep slope & back nailing requirements.
6.3.6 For Valleys and Ridges: Cut WIP roofing underlayment into manageable lengths. Align over
the center of the valley, hip or ridge. Remove release film. Press the middle of the
membrane first before working toward the edges. For open valleys, cover roofing
underlayment with metal valley liners.
7. LABELING:
Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for plants covered under Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL, LLC— QUA9625; (847) 664-3281
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report C39180.12.11-1112
Certificate of Authorization #9503 FL6785-R5
Revision 2: 10/12/2012
Page 4of4
Plorida Building Code Online Page 1 of 2
�:.
mp
Cri id C.r
„Pp' BCIS Home Log In User Registration Hot Topics ; Submit Surcharge { Stats & Facts ; Publications i FBC Staff i BCiS Site Map Links :Search i
Busines
Professi nai USER: uc t Approval
c User
Regulation
Product Aooroval Menu > Product or ApoLion arch > Ap iication List > Applitatlon Detail
6c p
FL # FL10674-R8 E
I Application Type Revision
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
2010
Approved
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenSCorning.com
Greg Keeler
greg.keeler@owenscorriing.com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
mel.sancrant@owensco,rnig.com
Category
Roofing
Subcategory Asphalt Shingl s
ej
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
2 Evaluation Report Hardcopy Received
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Robert J.M. Nieminen .
PE-59166
UL LLC
09/26/2014
John W. Knezevich, PE;
2 Validation Checklist - Hardcopy Received
FL10674 R8 COI Trinity ERD Cl - Nieminen.odf
Standard
Year
ASTM D3161, Class F
2006
ASTM D3462
2007
ASTM D7158, Class H .
2007
http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2boQT... 6/ 19/2013
Florida Building Code Online }
Page 2 of 2
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
12/19/2012
12/20/2012
12/25/2012
02/04/2013
Summary of Products
i FL #
Model, Number or Name
Description
10674.1
Owens Corning Asphalt Roofing
aminated, starter, and hip & ridge
Shinnies and Starters
Limits of Use
Approved for use in HVHZ: No
ation Instructions
74 R8 II er121912FINAL OC Asphalt
Approved for use outside HVHZ: Yes
s FL10674-R8.pdf
7h,ird
Impact Resistant: N/A
d By: Robert 1. M. Nieminen PE - 59166
Design Pressure: N/A
d by Independent Third Party: Yes
Other: Refer to ER, Section 5.
tion Reports
74 R8 AE er121912FINAL OC Asphalt
s FL10674-RS.Pdf
d by Independent Third Party: Yes
Back Next
Con s :: 1940 North Monroe Street Tallahassee Fl. 32399 Phone' 850-487.1824
The State of Florida is an AA/EEO employer, Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.
-Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public
record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
t ® ___ M
Cre tt��r
http://floridabuilding.org/pr/pr_app_dtl.aspx?param=WGEVXQwtDgtBNbEY5 VD/o2boQT... 6/19/2013
I
TRINITY I ERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
EXTERIOR RESEARCH & DESIGN, Ll-C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report 037940.02.12-R2
FL10674-RS
Date of Issuance: 02/06/2012
Revision 2: 12/19/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING:I Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance, Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance; documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTIOIN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of, the Building Official.
This Evaluation Report consists of pages 1 through 6.
I
Prepared by:
The facsimile seal appearing was authorized
by Robert Nleminen, P.E. on 12/19/2012
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
Robert J.M. Nieminen, P.E. ""'`
:. jiJ�.��kt%,;.•� transmitted to the Product Approval Administrator and
Florida Registration No. 59166, Florida DCA ANE1983 to the named client
CERTIFICATIONIOF INDEPENDENCE:
1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity[ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the
product.
I
i
TRINITY j ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demlonstrated compliance with the following sections of the Florida Building Code and Florida Building
Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Sectign Property Standard
Year
15071.2.5, R905.2.4 Physical Properties ASTM D3462
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F
2007
2006
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H
I
2O07
3. REFERENCES:
912fiiX Examination Reference
gate
UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3
UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453
02/15/2007
05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263
11CA34308
04/18/2006
02/18/2012
UL LLC (TST9628) Wind Resistance
Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12
02/14/2008
Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12
12/16/2009
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09
10/27/2010
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07
10/27/2010
06/16/2011
Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03
07/19/2012
Miami -Dade (CER1592) FBC HVHZ Compliance 12-0309.01
UL LLC (QUA9625) Quality Control Service Confirmation R2453
Exp. 09/26/2014
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.11 Classic® and Supreme` are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 Duration', TruDefinition° Duration°, Duration`s Premium Cool, TruDefinition� Duration
Designer Color Collection, TruDefinition® Oakridge°, Oakridge� and
WeatherGuard° HP are
fiberglass reinforced, laminated asphalt roof shingles.
4.2. Berkshires Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant,
WeatherGuard@ HP Hip
& Ridge Shingles and ProEdge Hip & Ridge Shingles are fiberglass reinforced,
hip and ridge
asphalt roof shingles.
4.31 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 , This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-112
Certi>,cate of Authorization #9503 FL10674-RS
Revision 2: 12/19/2012
Page 2 of 6
6.
I
TRINITY l ERD
5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating
the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,,,t = 194 mph).
Refer to Section 6 for installation requirements to meet this wind rating.
5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in
accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,,,t = 194 mph). Refer
to Section 6 for installation requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.3.;4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
INSTALLATION:
i
6.1 Underlayment:
6.1. 1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4
or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
or R905.2, with the following exceptions:
Berkshire° shingles require minimum five (5) nails per shingle.
> WeatherGuardO HP shingles require minimum six (6) nails per shingle.
> Starter Strip Plus requires minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing - Classic® & Supreme:
Moroni Rurnaw or Arw pare
yyiod Anaa High Wind davanaa Y
Arse pan viarrns nsmralaa Anaa vhutw hrsrtaa
it Espowra
Eapoaietdn
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Moroni Man$" or At" pai
Wind Anaa Nigh WMd dawanH Y
Arse pas visMw noarwiaa Anna vhnrw !vanes
n• {irJ r r r is r +.
6wi8 EW.-
EapoWcMn
Evaluation Report 037940.02.12-112
FL10674-RS
Revision 2: 12/19/2012
Page 3 of 6
Minimum Nailing - Berkshire@:
Saba Strip
G th de sdhdor
8 W
1' t�
TRINITY ERD
saatatiauip
La firs do sdtsdor
1
a
r As*k roof09 t
cars»:& ds tss&ds adstro
Minimum Nailing - Duration& TruDefinition@ Duration, Duration@ Premium Cool &
TruDefinition' Duration3 Designer Color Collection:
4 Nall Mom
Esquoma d• 4 davos
sum1Ur,tnwnN awn wWth
Awdtdaws SuwNar
1' t
�. 17
WeExpoww Naps ��6�u•
�fpul9.dssxposiWn ciswS 64pul9.dSW0S"n
6 Nap
Paftern
Esw
'N.namexmeNn
Wpnpt..nxunM,
'"000DI.t1d.
d6da a
ws wYi±w�
• • •
l�raarrama
it5`J.
\
GAMhpp
ttq�'.
!'aMSA
fun it'
I`3E
tr 1T,
fiv Eposme
Naps ss"
Expowe
5i4PWa•defilpo.*i6n
Caws 54
paig• do evasiddn
Minimum Nailing - TruDefinition° Oakridge@, Oakridge®:
4 Nail Fattarn
Espatw can 4 davos
t, t.
It— r< —►I 14-- u—>I
66fg' Edpmun rkib 6 b/a" Expeww
EXPoddandSG&$ W9. cbms Expasiddndo6VSPal;
Exterior Research and Design, LLC.
certificate of Authorization #9503
I
6 Nail Pattam
Esgaatna cat 6 davos
t. r
Nava 6R'E
65/0'i&POSU5
66/BpW9. Cbvm EXSAr,!expn6rosaw66141 WiL
Evaluation Report 037940.02.12-R2
FL10674-R8
Revision 2: 12/19/2012
Page 4 of 6
i
6.2.9
6.3 1
6.3.1
6.3.2
6.3.3
6.3.4
i
TRINITY ERD
Minimum Nailing - WeatherGuard® HP:
aer vr.
Vb" MOW
Hip & Ridge Shingles:
Installation of Berkshire' Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant,
WeatherGuard°r HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with
the manufacturer's current published instructions, using four (4) nails per shingle. Refer to
Owens Corning published information on wind resistance and installation limitations, including
the use of hand -sealing for wind warranties.
Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
Minimum Nailing - Berkshire® Hip & Ridge and High Ridge:
Fig. 1 4
f— preratang lNnd
TMredlon (�� F'
A
Haas ---
I I
4
p I I j
Minimum Nailing - Hip & Ridge with Sealant:
om Fig. 2 - W795Wkw FastowNg Proem
4 Naiis
rim Shingle—
nd Discard 2,2•
Exc* ss
Sealgnit 12"
Step T •
' Fastening 4S"Exposure
Distance
12"
FIp. 2
TopMew sm"M
Naas-tj j He"s
T T 1 Top LaW90W
_ I Pima I
a
I
I
I
�I
I
I
e-; i
I �
V` II
� I
----tr
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-112
Certificate of Authorization #9503 FL10674-RS
Revision 2: 12/19/2012
Page 5 of 6
7.
B.
9.
10.
6.3.
I
Minimum Nailing - WeatherGuard@ HP Hip and Ridge:
Fig. A 9 q
vrowabgmne ✓'
4"— grodbn A
P
Nobs o q
� A
4 I 1
I I I 1
I 1
rTRINjERD
ITY
Fig. C Hip & Ridge Shingle Fastening
TopVW
N3II6 N91te
7'
Ir
Minimum Nailing - ProEdge Hip & Ridge Shingles:
F'nvaging
WindDi►eetion S"dmStrip `
FuWn7V
F.=
Roof PtnwM
I
LABELING:
Standard ��•_.
Fastening
Pattern �
r� I•I ~�I �--r
12- s.,w+t
7A Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
I detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
MANUFACTURING PLANTS:
ContI act the named QA entity for information on which plants produce products covered by Florida Rule
9N-3 QA requirements.
QUAILITY ASSURANCE ENTITY:
UL LILC- QUA9625 ; (414) 248-6409; karen buchmann@ul.com
I
- END OF EVALUATION REPORT -
I
ExteriorlResearch and Design, LLC. Evaluation Report 037940.02.12-112
certificate of Authorization #9503 FL12012
Page /
Revision 2: iP196 of 6
I
I
Florida Building Code Online
i
Page 1 of 2
ps^kb5 unfi '`. a [.a 3acr _ 1
Itsf,,.
�I r .
� ... � .. �'".i�k1Y•A.
\.7,01 .. t_,•,i, BCIS Home Log In User Registration Hot Topics Submit Surcharge i Stats & Fads Publications i FBC Staff BCIS Site Map Links Search
( Business"'�
nal � USERduccUser Approval
Profess io'
• rocuct Approval Menu > Produc, or Anolicption Seam > Applied. or• List > Application Detail
FL # FL6785-R5
Application Type Revision
Code Version "'����_:
Application Status proved
Comments
Archived
Product Manufacturer Carlisle Coatings & Waterproofing
Address/Phone/Email 900 Hensley Lane
Wylie, TX 75098
(717) 245-7000 Ext7456
wert@syntec.car[isle.com
Authorized Signature Chad Wert
wert@syntec.Carlisle.com
Technical Representative
Address/Phone/Email,
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments�
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
LJj Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
I Certificate of Independence
Referenced Standard and Year (of Standard)
I
Equivalence of Product Standards
Certified By
i
Sections from the Code
Robert Nieminen
PE-59166
UL LLC
11/08/2013
John W. Knezevich, PE
Z Validation Checklist - Hardcopy Received
FL6785 R5 COI Trinity ERD CI Nierttinell df
Standard Year
ASTM D1970 2001
http://floridabuiIdin or / r/ r_a dtl.as x? aram=wGEVX wtD vkd KnnfaL B2sB%... 7/17/2013
g• g P P PP_ P P Q q Y g
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted
10/12/2012
Date Validated
10/15/2012
Date Pending FBC Approval
10/22/2012
Date Approved
12/04/2012
JYIror � v
FL # Model, Number or Name
IDescription
6785.1 CCW Roof Underlayments
Self -Adhesive Roofing Underlayments
Limits of use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: 1.) Refer to ER Section 5 for
Limits of Use 2.) Refer to ER Section 6 for
Installation Instructions
Ft...6785 R5 11 er1012.12FINAL CARLISLE UNDERLAYHE..N15 FL.6785_
R5.Ddf
Verified By: Robert Nieminen 59166
Created by Independent Third Party: Yes
Evaluation Reports
FL6785 R5 AE er101212FINAL CARLISLE UNDERLAYMENTS FLf:;735
RS.Ddf
Created by Independent Third Party: Yes
Installation.
back Next.
Contact Us :: 1940 North Monroe Street Tallahassee FL 32399 Phone; 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2010 State of Florida :: Privacy Statement :: ACcesSibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.
'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public
record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
l]
security �i�.
I
http://floridabuilding.org/pr/pr app dtl. aspx?param=wG EV XQwtDgvkdyKrm faLgB2 sB %.
7/17/2013
..` TRINITY
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
ERD OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
Carlisle Coatings & Waterproofing
900 Hensley Lane
Wylie, TX 75098
Evaluation Report C39180.12.11-R2
FL6785-RS
Date of Issuance: 12/09/2011
Revision 2: 10/ 12/ 2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed 'by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: CCW Roof Underlayments
LABELING:; Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance; Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance; documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 4.
Prepared by:
- � The facsimile seal appearing was authorized
=�'. -, -epp• by Robert Nieminen, P.E. on 10/12/2012
'• =�•.
�': This does not serve as an electronically signed
•%,; r1
J-k Nieminen, P.E.
R "'' �'� =' document. Signed, sealed hardcopies have been
s�rC ;; `P transmitted to the Product Approval Administrator and
Robert
Florida Registration No. 59166, Florida DCA ANE1983
"""""" to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinityiERD does not have, nor does it intend to acquire
or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinityJERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
financial interest in any company manufacturing or distributing products for which
3. Robert Nieminen, P.E. does not have nor will acquire, a
the evaluation reports are being issued.
have, will acquire,
a financial interest in any other entity involved In the approval process of the
4, Robert Nieminen, P.E. does not nor
product.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
i
Product Category: Roofing
SubL Category: Underlayment
Compliance Statement: CCW Roof Underlayments, as produced by Carlisle Coatings & Waterproofing,
have demonstrated compliance with the following sections of the Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
i
2. STANDARDS:
Section Property Standard Year
1507.2.4, 1507.2.9.2, Physical Properties ASTM D1970 2001
1507I.5.3
3. REFERENCES:
Entity
Examination
ERD (TST6049)
Physical Properties
MTI (TST2508)
Physical Properties
MTI (TST2508)
Physical Properties
MTI {TST2508)
Physical Properties
M-D (CER1592)
HVHZ Compliance
ICC-ES (EVL2396)
2009 IBC Compliance
ICC-ES (EVL2396)
2006 IBC Compliance
UL, LLC. (QUA9625) Quality Control
UL, LC. (QUA9625) Quality Control
Reference
Date
C41280.10.12
10/05/2012
PX02MOA
01/17/2011
PXI6MOA
01/18/2011
PX13MOB
01/18/2011
09-0630.13
08/12/2009
ESR-1556
03/01/2012
ESR-2206
03/01/2012
TGDY.R18678 Listing
10/18/2010
Inspection Report, R18678
02/20/2012
I
4. PRODUCT DESCRIPTION:
4.1. CCW WIP 100 is aself-adhering, fiberglass reinforced, granule surfaced, rubberized asphalt
roof underlayment.
4.2 CCW WIP 250 is a self -adhering, fiberglass reinforced, film surfaced, rubberized asphalt roof
underlayment.
4.3 CCW WIP 300HT is a self -adhering, coated- polyolefin-co m posite film surfaced, rubberized
I asphalt roof underlayment.
I
5. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.3 CCW Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to
i the AHJ for approval based on this evaluation combined with supporting data for the prepared
roof covering.
I
i
Exterior Research and Design, LLC. Evaluation Report C39180.12.11-R2
Certificate of Authorization #9503 FL6785-R5
Revision 2: 10/12/2012
Page 2 of 4
I
5.4
I
5.5
i
5.5.1
i
5.5.2
1
5.6 1
5.6.1
�,., _....� ;rr
`'�"J TRINITY ERD
Allowable roof covers applied atop the underlayments are follows:
Table 1: Roof Cover Options
Underlayment
Asphalt
Shingles
Nall -On Tile
Foam -On
Tile
Metal
Wood
Shakes &
Shingles
Slate &
synthetic
Slate/Shake
CCW WIP100
Yes
No
No
No
No
No
CCW WIP 250
Yes
No
No
Yes
No
No
CCW WIP 300HT
Yes
No
No
Yes
No
Yes
Allowable substrates are noted below:
Direct -Bond to Deck:
Self -adhering membranes applied to:
New untreated plywood;
Primed new untreated plywood;
Existing plywood;
Primed existing plywood;
Note: While not required, CCW-702 or CAV-GRIP primer may be used when deemed
appropriate or when temperatures are below 40°F.
Bond to Mechanically Attached Base Laver:
Self -adhering membranes applied to:
ASTM D226, Type I or II felt;
For installations under mechanically attached prepared roof coverings, base layer shall be
attached per minimum codified requirements.
Exposure Limitations:
CCW WIP 100, CCW WIP 250 and CCW WIP 300HT shall not be left exposed for longer than
30-days after installation.
6. INSTALLATION:
6.1 CCW Roof Underlayments shall be installed in accordance with Carlisle Coatings &
Waterproofing published installation requirements subject to the Limitations set forth in
Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the
substrate thoroughly to remove any dust and debris prior to application. Prime the substrate
(if applicable) with CCW-702 or CAV-GRIP Primer.
6.3 CCW WIP 100 CCW WIP 250 and CCW WIP 300HT:
1
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC
I Sections 1507 for the type of prepared roof covering to be installed.
6.12 While not required, CCW-702 or CAV-GRIP primer may be used when deemed appropriate.
Priming is required when temperatures are below 40°F.
6.3.i 3 Cut WIP roofing underlayment into 10 to 15 ft lengths. Remove 2 to 3 ft of release film and
align the edge of the membrane, sticky -side down, so it overhangs the drip edge by 3/8-inch.
Continue to remove release film and press as you move across the roof. Use a hand roller
and/or hand pressure to press into place.
Exterior, Research and Design, LLC. Evaluation Report C39180.12.11-R2
Certificate of Authorization #9503 FL6785-R5
Revision 2: 10/12/2012
Page 3 of 4
I
J` TRINITY ERD
6.3,.4 Horizontal seams should be minimum 3.5-inches, configured to shed water. Vertical seams
should be 6-inches and staggered not less than 2-ft from vertical seams in the course below.
6.3,.5 Consult Carlisle Coatings & Waterproofing for steep slope & back nailing requirements.
6.3.6 For Valleys and Ridges: Cut WIP roofing underlayment into manageable lengths. Align over
the center of the valley, hip or ridge. Remove release film. Press the middle of the
membrane first before working toward the edges. For open valleys, cover roofing
under►ayment with metal valley liners.
1
7. LABELING:
Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
I
S. BUILDING PERMIT REQUIREMENTS:
As irequired by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MA NUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for plants covered under Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL,j LLC- QUA9625; (847) 664-3281
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report C39180.12.11-R2
Certificate of Authorisation #9503 FL6785-1115
Revision 2: 10/12/2012
Page 4 of 4
� - J
OFFICE USE ONLY:
DATE FILED: �� 3
REVISION FEE: O
1
2.
3.
4.
5.
LOCATION/SITE
ADDRESS:
N C
t (UC/A C. PERMIT # 5
RECEIPT # CO J
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
tl
FORT PIERCE, FL 34982-5652 ;
(772) 462-1553 f UU)l l.j
APPLICATION FOR BUILDING PERMIT REVIS
PROJECT INFORMATION
Y `J
DETAILED DESCRIPTION OF PROJECT
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: ' -T. LUCIE COUNTY CERT. #: .L �'SC9 I zS
BUSINESS NAME: 0
QUALIFIERS NAME: ALL, Ir
ADDRESS: Y
CITY: i STATE: ZIP:
PHONE (DAYTIME): 4�����L�b FAX:Q-
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE:
ARCHITECT/ENGINEER INFORMATION:
I
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME): F; =mz; s
SLCCC: 9/23/09
Revised 04/26%2010v5
m, 1 .��
STATE:
FAX:
STATE:
N.
t 4 �
FAX:
ZIP:
ZIP:
DEPARTA
BOARD A
NOTI(
Johns M
71.717th
Denver,
ENT OF REGULATORY AND ECONOMIC
1D CODE ADMINISTRATION DIVISION
E OF ACCEPTANCE (NOA
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR CO f3
REVIEWED BY
DATE / r IMIA vti-DADS COUNTY
PLANS AND PER IT
MUST BE KEPT ON JOB OR �ODUCT CONTROL SECTION
NO INSPECTION WILL BE MADE 11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 31525-99
wwrv.miamidadc.yov/economv
C t4& P5.1
SCOPE:
This NO, is being issued under the applicable rules and regulations governing the use of construction
materialsi The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product ddontrol Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material, tested for quality assurance purposes. If this product
or material fails to perform in the accepted manner, the manufacturer will incur the expense of such
testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material
within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
He Corporation
:et
80202
This product is approved as described herein, and has been desilmed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Johns Manville A.PP Modified Bitumen Rooting Systems Over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
followinlg statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
I
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayid, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 12-0123.06 and consists of pages 1 through 15.
The submitted documentation was reviewed by Jorge L. Acebo.
i�71
r i �: �, � j r� 1 NOA No.: 13-0129.03
�• �l Expiration Date: 06/14/16
Ill , pproval Date: 06/06/13
Page 1 of 15
Ll LJ �J
I
ROOFIN G SYSTEM APPROVAL
Cate orv: Rooting i 1
g I �� ! P 1
Sub-Catesorv• Modified Bitumen
materials:
Wood J `'
Deck Type: e.-- ..
Maximum Design Pressure -52.5 psf
I
TRADE NAMES OF PRODUCTS MANUFACTURED OR .LABELED BY APPLICANT:
TABLE 1
Product
JM APP Base
I
APPeX� 4S
A APPeXI 4.5M
4.5M FR
Tricor
Tricor
f PermaPly 28
V
GlasBiase Plus
I
Test
Product
Dimensions
Specification
Description
39-3/8" x 48'
ASTM D 6509
APP modified asphalt, fiberglass
reinforced, smooth surfaced base sheet.
39-3/8" x 34'
ASTM D 6222
APP modified asphalt, polyester
Type I
reinforced, smooth surfaced membrane
Grade S
for use as a Base and/or Ply Sheet only.
39-3/8" x 34'
ASTM D 6222
APP modified asphalt, polyester
Type I
reinforced, mineral surfaced membrane.
Grade G
39-3/8" x 34'
ASTM D 6222
APP modified asphalt, polyester
Type I
reinforced, fire -retardant, mineral surfaced
Grade G
membrane.
39-3/8" x 34'
ASTM D 6223
APP modified asphalt, polyester / glass
reinforced, granule surfaced membrane.
39-3/8" x 34'
ASTM D 6223
APP modified asphalt, polyester / glass
reinforced, smooth surfaced membrane
for use as a Base and/or Ply Sheet only.
36" x 106';
ASTM D 4601
Type lI asphalt impregnated and coated
72 lb. roll
glass fiber base sheet
36" x 36'
ASTM D 4897
Heavy duty fiber glass base sheet
Type II
impregnated and coated on both sides with
asphalt with or without fine mineral
stabilizer.
36" x 106'
ASTM D 4601
Type II SBS and asphalt blend
impregnated and coated glass fiber base
sheet with fine mineral stabilizer.
{
NOA No.: 13-0129.03
Expiration Date: 06/14/16
Approval Date: 06/06/13
Page 2 of 15
APPROVED INSULATIONS:
Product Name
I
ENRGY 3, ENRGY 3 25 PSI
Fesco Fi am, DuraFoam
Retro-Fit Board, DuraBoard
Fesco Board
I
StructodekHigh Density Fiber
Board Roof Insulation
Numb,
2.
3.
4.
5.
6.
7.
8.
TABLE 2
Product Description
Isocyanurate Insulation.
Isocyanurate Insulation with perlite facer.
High -density perlite roof insulation.
Rigid perlite roof insulation board.
High Density Fiber Board.
Manufacturer
(With Current NOA)
Johns Manville
Johns Manville
Johns Manville
Johns Manville
Blue Ridge Fiber Board,
Inc.
1 'Y
ED FASTENERS: 73COP
TABLE 3 {
Product Product Manufacturer
Name Description Dimensions (With Current NOA)
UltraFast Fasteners insulation fastener for wood Various Johns Manville
and steel.
U1traFast ASAP Pre -assembled Insulation Various
fastener and plate
UltraFast 3" Round Metal Galvalume AZ55 steel plate 3" round &
Plate or Square Recessed 3" square
Metal Plate
#12 Standard Roofgrip
ASAP Roofgrip
3" Round Metal Plate or
Flat Bottom Metal Plate
Tru-Fast HD Fastener
(# 14)
Tru-Fast 3" Metal
Insulation Plate
Insulation fastener Various
Pre -assembled Insulation
Various
fastener and plate
Galvalume AZ50 steel plate
3" round
& 3" square
Insulation fastener for steel
Various
and wood decks
Galvalume AZ55 steel plate 3" round
Johns Manville
Johns Manville
OMG
OMG
OMG
Altenloh, Brinck &
Co. U.S., Inc.
Altenloh, Brinck &
Co. U.S., Inc.
NOA No.: 13-0129.03
Expiration Date: 06l14/16
Approval Date: 06/06/13
` Page 3 of 15
EVIDENCE SUBMITTED:
Test Aaencv Test Identifier Description Date
Factory Mutual Research Corp. J.I. OXOA9.AM 4470 03/25/94
J.I.OW6A2.AM 4470 02/05/93
J.1.OX7A4.AM 4470 08/26/93
J.1. 3001482 4470 08/ 11 /98
J.1. 3002823 4470 04/01/99
J.1. 3003468 4450 02/02/00
J.1. 3007148 4470 04/19/00
3009499 4470 04/04/01
3011248 4450 11 /01 /02
3012974 4470 06/03/02
Underwriters Laboratories, Inc. R10167 UL 790 05/27/13
Exterior Research & Design, LLC #4361-2.04.97-1 TAS 114(J) 04/15/97
10390A.12.97-1 TAS 114(J) 12/15/97
10390A.10.97-1 TAS 114(J) IOi15/97
10391.01.03 TAS 114(J) 01 /29/03
PRI Construction Materials, LLC JMC-053-02-01 ASTM D5147/D6222 05/01/13
JMC-054-02-01 ASTM D5147/D6223 06/04/12
JMC-055-02-01 ASTM D 6509 05,129/12
JMC-070-02-01 ASTM D 2178 TYPE IV 04/17/12
JMC-071-02-01 ASTM D 2178 TYPE VI 04/17/12
JMC-072-02-02 ASTM D 4601 06/04/12
JMC-074-02-01 ASTM D 4897 04/17/12
JMC-093-02-01 ASTM D 4601 08/02/12
'Y 1t�it1�
I
j
j NOA No.: 13-0129.03
CMLAM1i1D.AQECOUNTY Expiration Date: 06/14/16
Approval Date: 06/06/13
Page 4 of 15
I
I
-
I
Membrane Type:
APP
Deck Type 11:
Wood, Non -Insulated / I
Deck Description:
'y62" or greater plywood or woad plank -
System Type E:
Base sheet mechanically fastened.
All General and System
limitations apply.
Base Sheet:
(Option #1) One ply of JM APP Base, PermaPly 28, Glasbase Plus or
Ventsulation mechanically fastened to the deck with JM U1traFast, OMG Roofgrip
or Tru-Fast metal plates and fasteners at a 4" side lap 12" o.c. and two rows
staggered in the center of the sheet 18" o.c.
(Maximum Design Pressure —45 psf, See General Limitation #9.)
(Option #2) Minimum two plies of JM PermaPly 28 or Ventsulation
simultaneously fastened to the deck lapped 4" and fastened with approved roofing
nails and tin caps 9" o.c. at the lap and two rows staggered in the center of the
sheet 12" o.c.
(Maximum Design Pressure —52.5 psf, See General Limitation #7.)
(Option #3) Minimum two plies of JM PermaPly 28 or Ventsulation
simultaneously fastened to the deck with JM Ultrafast fasteners and Metal Plates
spaced 9" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the
sheet.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Ply Sheet:
(Optional) One or more plies of JM APP Base or APPeX 4S heat welded to base
sheet while maintaining 4" side laps and 6" end laps.
Membrane:
One or more plies of APPeX 4.5M or APPeX 4.5M FR heat welded while
maintaining 4" side laps and 6" end laps.
Surfacing:
(Optional) Install one of the following for all systems that do not achieve
acceptable fire ratings through the use of FR membrane sheets. Any coating, listed
below, used as a surfacing, must be listed within a current NOA.
1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at
a rate of 60 lb./sq.
2. Karnak 97, Karnak 97 AF, Monsey Premium Long Life Aluminum Roof Coating
Asbestos Free or Monsey Prograde Aluminum, Grundy AL MB aluminum coating
at a rate of 1-1/2 gal/sq. Monsey Aquabrite, Gardner asphalt emulsion, APOC
Sunbright 400 or Henry 229 Aluminum Emulsion at 2'/ gal/sq. or APOC 212
Aluminum Roof Coating at 3 gal/sq.
3. Grundy 20 F asphalt emulsion, Endure Asphalt Emulsion, APOC 302 or 302 AF
applied at 2'/2 gal/sq. with optional 60 lbs./sq. of roofing granules embedded in wet
coating.
Maximum Design
Pressure:
See Fastening Options
NOA No.: 13-0129.03
Expiration Date: 06/14/16
MIAMI-DADE COUNTY Approval Date: 06/06/13
Page 14 of 15
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with Ply 4 and Ply 6. when used as a ,m ch�ani ally fastened-b' aseI or anchor
sheet.
GENERAL LIMITATIONS:
1. Fire', classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All 'standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 121bs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered
Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Rooting Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS I I 1 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 9N-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 13-0129.03
MIAM�•DADEeouNTY Expiration Date: 06/14/16
Approval Date: 06/06/13