Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSf_ I DATE: L,/ : `"�� 1 '-) I FEES DUE: I " I RECEIPT #r/ /i '-'Y 1 / I Permit #:1 n % r. Planning & Development Services Department COUNTY Building & Code Regulation Division 2300 Virginia Avenue SCANNED Ft. Pierce, FL 34982-5652 BY Tel. 772-462-1553 APPLICATION FOR ROOF PERMIT St. Lucie County SEE REVERSE SIDE FOR INSTRUCTIONS 1. Location/Site Address: 1 U'1 15 Sou+k Ocean 12 Ye - DER 109 Teasen Bearh FL 34q S'1 2. Parcel ID Ni mber: _14511 - Sol - 0330 - 0oo - 1 Office Use Only Section Township Range Map Page Zoning Land Use Initials I F-RK v r-u� ccna 3. Description f Project or Work Activity: e -� o o �.K 0 Q U4'2 n s l o r Al 'Ski nq l 2S 4. Total Roof Area (square feet): q 0 O SF 5. Roof Pitch: 31 / a- 6. Type of Roof: N Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other 1>1 Product Approval required for all types of Roofing Material (2 Sets) i [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roofi Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: James 4 Ta-tri c. I q 16e R+ FL Reg/Cert #: L 0 0 0 3 to q q Q Address: a0.26 L- tlor, Streei- City: Eas+ 64en d State: Okio I Zip: 4 3g a0 Phone: 330.38 3 • 1 65q County Cert #: ga $ y Business Name: _ H P_a. oh R o ofi n4 -Ihc Cell Phone: 11`1 a - 4 S la • 3 01 a 9. Value of Construction: $ a , 4 00. 0 0 "Note Dry -in and,Final Inspection Required. Additional inspection may be required per Product Approval. CO O OWNER'S AFFIDAVIT: I certify that all of th ' formation contained in this application is correct and that all work will be done in compli th pplic ble regulating construction and zoning. r r.TATE QU IES/ W NA SI ATURE O QUALIFIER(OWNER OF FLORIDA, COUNTY OF 'ai r\ ACKNOWLEDGED BEI ORE ME THIS 444 DAY OF DQ c e m e r 2013 BY 1)6- Ll £,) �. F-i Uxfon WHO IS PERSONALLY KNOWN X TOME OR HAS PRODUCED AS IDENTIFICATION tic hta Ai.ahnp iYI'kuiun VIGhein -Dinr vw tY (Ah,en ?o�P".Y:�'��� VICTORIADIANNEMCIMIEN SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY (seal) *Al"."'Oev MY C011M ISSION # EE 2140 EXPIRES; July 21,2016 COMMISSION NUMBER E E a� y io Io a Bonded Tku Budget Notary $aunas NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 OJT Property Appraiser - St.Lu: ^ Coulnty, FL Page 1 of 1 James C Gilbert Record: 1 of 1 Property Identification Site Address: 10725 S OCEAN DR 109 Sec/Town/Range: 11 :37S :41 E Map ID: 45/11G Zoning: HIRD PROPERTY RECORD CARD «Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print ParcellD: 4511-501-0330-000-1 Account #: 123483 Use Type: Mob Homes City/Cnty: Saint Lucie County Ownership and Mailing Owner: James C Gilbert Patricia A Gilbert Address: 2026 Lisbon St East Liverpool OH 43920 Sales Information Date Price Code Deed 10/9/2009 100 0130 WD 9/4/2009 100 0119 PR 8/21/2009 100 0130 WD 7/24/2009 100 0130 WD 7/10/2009 100 0130 WD 3/1/1976 8000 01 CV Legal Description HOLIDAY OUT AT ST LUCIE BLK K LOT 33 AND EQUAL PRO-RATA INTEREST IN COMMON ELEMENTS (OR 250-2166; 31 More.. Assessment 2013 Book/Page 2013 Final: 62700 3138/1061 Assessed: 62700 3130 / 2151 Ag.Credit: 0 3130 / 2156 Exempt: 3130 / 2155 Taxable: 3130 / 2153 Taxes: 1269.82 0250 / 2166 BUILDING INFORMATION Total Land and Building Land Value: 40300 Acres: 0.05 Building Value: 22400 Finished Area: 713 SgFt Exterior Features View: RoofCover: - RoofStruct: - ExtType: MHH - MHH YearBlt: 1989 Frame: - Grade: PKMA - PKMA EffYrBlt: 1989 PrimeWall: - StoryHght: 0010 -1 Story No.Units: 1 SecWafl: - Interior Features BedRooms: 0 Electric: - PrmintWall: - FullBath: 0 HeatType: FHA - FrcdHotAir AvgHtlFI: 1/26ath: 0 HeatFuel: ELEC - Electric Prm.Flors: - %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Use Type Type Measure Depth 1 0200-Mob Homes BI -Site 1 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/paslc/prc.asp?prclid=451150103300001 12/3/2013 Florida Building Cod, 'iline Page 1 of 3 S �a f c s r ,. ....,'� R�� ,.�u{ 4,..wKY,�,{y�,�.b�,'t.t"a,P`�,s���a��..�,{*J7,A14 �'�.,a ,�-s�o�•,a.•�� l�idmi'I?",r� 3 ( rfl( BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Busines Professil *N.Product Approval USER: Public User Regulation IUMMiRMISROM Product Approval Menu > Product or Application Search > Application List > Application Detali FL # FL7006-R4 Application Type Revision Code Version 2010 Application Status Approved *Approved by DCA. Approvals by DCA shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Archived I Product Manufacturer IKO Industries, Ltd j Address/Phone/Email 40 Hansen Road So Brampton, NON-U 6 H (708)496-2800 Ext20 rmetz001@tampabay -130 Authorized Signature Robert Metz rmetz001@tampabay.rr.c Technical Representative Bob Metz z Address/Phone/Email REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 (727) 776-5261 rmetz001@tampabay.rr.com Quality Assurance Representative Andy Lodge Address/Phone/Email IKO Industries LTD 40 Hansen Road S. Brampton, FL 33703 (727)525-0342 rmetz001@tampabay.rr.com Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency FM Approvals - CER Validated By Zachary R. Priest, P.E. Validation Checklist - Hardcopy Received i Referenced Standard and Year (of Standard) Standard Year ASTM D3161 modified to 110 mph 2006 ASTM 93462 2007 ASTMIE108 2007 Equivalence of Product Standards Certified By f http://www.floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgse7mYBd2b3 K... 4/24/2012 Florida Building Co(; )nline Page 2 of 3 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option A 03/06/2012 04/17/2012 04/23/2012 Summary of Products FL # Model, Number or Name Description 7006.1 Cambridge AR and CRC Biltmore Laminated architectural fiberglass asphalt shingle AR manufactured at IKO's Kankakee, IL, Hawkesbury, Ont., Wilmington, DE and Toronto, Ont. plants Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL7006 R4 C CAC 797-07219-267 - FBC ASTM certification letter - 3-1-2 12 , df Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7006 R4 C CAC Shingle letter ASTM Compliance - 4-1 -2012 . f Design Pressure: N/A Other: Quality Assurance Contract Expiration Date 12/31/2018 Installation Instructions FL7006 R4 II 67TEFS-2012-01 8 5 x it Aoolication Instructions 3-2012. df Verified By: FM Approvals - CER Created by Independent Third Party: Evaluation Reports 11 Created by Independent Third Party: 7006.2 Hip and Ridge 12 Cap fiberglass This Is a 12" x 12" fiberglass asphalt shingle used to shingles cover the hip and/or ridge of an asphalt shingle roof system manufactured in Toronto, Ont. and Brampton, Ontario Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL7006 R4 C CAC 797-07219-267 - FBC ASTM certification letter - (3-1-2012).pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7006 R4 C CAC Shingle letter ASTM Compliance - 4-16-2012 . df Design Pressure: N/A Other: Quality Assurance Contract Expiration Date 12/31/2018 Installation Instructions FL7006 R4 II Hip and Ridge Cap Shingle Installation Ins ruc ons. f Verified By: FM Approvals - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 7006.3 Leading Edge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter Starter Strip strip at the bottom of a roof system manufactured In Brampton, Ontario plant Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL7006 R4 C CAC 797-07219-267 - FBC ASTM certification letter - 3-1-2012 . df Approved for use outside HVHZ: Yes Impact Resistant: N/A FL7006 R4 C CAC Shingle letter ASTM Compliance - (4-16-2012).pdf Design Pressure: N/A Other: Quality Assurance Contract Expiration Date 12/31/2018 Installation Instructions FL7006 R4 II Leading Edge Plus Installation Instructions. df Verified By. FM Approvals - CER Created by Independent Third Party: Evaluation Reports = Created by Independent Third Party: 7006.4 Marathon 25 AR, CRC Superglass 3 tab fiberglass asphalt shingle manufactured at IKO's M25AR Brampton, Ontario, Hawkesbury Ont., Toronto and Kanakakee, IL plants Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL7006 R4 C CAC 797-07219-267 - FBC ASTM certification letter - 3-1-2012 , df Approved for use outside HVHZ: Yes i http://wvyw.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgse7mYBd2b3K... 4/24/2012 Florida Building Co, Wine Page 3 of 3 Impact Resistant: N/A Design Pressure: N/A Other: duality Assurance Contract Expiration Date 12/31/2018 nstallation Instructions Verified By: FM Approvals - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Cooyrloht 2007-2010 State of Florida.:: Privac4 Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronlc mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions regarding DBPR's ADA web accessibility, please contact our Web Master at webnrastertmdbor.state.fl.us. Product Approval Accepts: ® eCtreck NOrttxl sccurit �ausures SECURED p.—,,d by yarlSign I I , ' I, I http://www.florldabuilding.org/pr/pr_app_dtl.aspx . param—wGEVXQwtDgse7mYBd2b3K... 4/24/2012 NOVEMBER 2004 No. R-50 REV. — JUNE 2012 FLORIDA STATE APPROVALS IKO has achieved additional Product Approval for its line of shingles, including accessory products in the. State of Florida. See the chart below which summarizes the latest information, along with some key !installation data. The shingles listed meet all current Code requirements. IKO SHINGLE Exposure Offset Shg/sq M-D # (expiration) Cambridge AR * 5-7/8" 4 —10" 60 11.0517.09 (5/5/16) Marathon, 25 AR * 5-5/8" Min. 4" 65 11.1121.02 (5/5/16) Hip & Ridge 12 * 5-1/8" - - 11.1121.01(5/19/16) Leading Edge Plus * 6-5/8" - 11.0318.02 (5/12/16) ArmourShake ** 5" Min. 4" 70 - Crowne Slate ** 10" 4-1/2- 40 Grandeur," 5-7/8" 4-10" 60 - MarathonlUltra AR ** 5-5/8" Min. 4" 60 - Royal Estate ** 5-5/8" Min. 4" 64 - *Florida Approval FL7006-134, ** Florida Approval FL15550-RI, ASTM E 108 Class A, ASTM D 3161 Class F, and ASTM D 7158 Class H Visit www.iko.com for complete technical data, application instructions, and limited warranty information. i The subject shingles conform to the requirements of ASTM's D 3462 product standard for glass fiber reinforced asphalt shingles, as well as ASTM's D 3161 test method for wind resistance, modified tot, 110 mph. Miami -Dade approved product bears the Miami -Dade logo on the product wrappers and shingle release film. Visit http://www.miamidade.gov/building/pc-search app.asp for specific details. I For additional information on any of IKO's products or application requirements, visit us on the web at,www.iko.com, or contact us in Canada at 1-888-766-2468, or the United States at 1-888-456-7663. Ko Setting the Standard I MIAMt•=WE Im _ - I BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE I Iko Industries Ltd. 40 Hansen Rd. S. Brampton, Ontario CANADA L6W3H4 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33I75-2474 T (786) 315-2590 F (786) 315-2599 www.roiRmidade.eov/bu ildino/ This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section1to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section'(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to havethis product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined' by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Cambridge AR I LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been fled and there has been no change to the applicable building code negatively affecting the performance of this product. I TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the requept of the Building Official. This revises NOA# 10-0913.02 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 11-0517.09 MIAMMADE COUNTY Expiration Date: 05/05/16 • • Approval Date: 07/07/11 i Page I of 4 ROOFi ING ASSEMBLY APPROVAL Cateeory Roofing Sub-Cateeory: Asphalt Shingles Materials Laminate Deck Tune• Wood i SCOPE This approves a roofing system using Cambridge AR asphalt shingles manufactured by IKO Industries Ltd. as described in Section 2 of his Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Descrintion Specifications Cambridge AR 13 3/4" x 40 7/s" TAS 110 A heavy weight, fiberglass reinforced laminate asphalt shingle. MANUFACTURING LOCATION 1. Kankakee, IL EV]DENCE SUBMITTED Test Aaencv i Test Identifier Test Name/Repo rt Date PRI Coistruction Materials Inc: IKO-050-02-01 TAS 100 12/21/09 FM Appi ovals 3041689 ASTM D 3462 02/23/11 FM Approvals 3036971 ASTM D 3161 -(TAS-107) 01/04/09 FM Approvals 1 3042673 ASTM E 108 04/12/11 LEM ATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. INSTALLATION l . Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Plashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail W, attached. 5. Nailing shall be in compliance with Detail 113 attached. NOA No.: 11-0517.09 rn�►Madeaue COUNTY Expiration Date: 05/05/16 Approval Date: 07/07/11 Page 2 of 4 LABELING - 1. Shingles shall be labeled with the Miami -Dade Seal as Been below, or the wording "Miami -Dade County Product Control Approved". I MIAM[QADE COUNTY ,�..O BUILDING PERMIT REQUIREMENTS l . Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly j evaluate the installation of this system. .�i Mwta1�ADECOUNrir I NOA No.: 11-0517.09 Expiration Date: 05/05/16 Approval Date: 07/07/11 Page 3 of 4 i I DETAIL A CAMBRIDGE AR COURSE LAYOUT I DOE OF ROOF --------------------- 30» Note: Roofing Cemant not shown In this layout This drawing isfor course Isyaut only. See wtaiiB ----- for nailing and cement plaoement details. THIRD COURSE I I I i------i------ SECOND COURSE I I NINE r//////A 0 0 0 0 a 0 I I I � I FIRST COURSEIN I I I DETAIL B CAMBRIDGE AR 40 7n B 13 4" C 111 I (J I END 4F THIS ACCEPTANCE 11 m 5 EXPOSURE --JI NOA No.: 11-0517.09 Expiration Date: 05/05/16 Approval Date: 07/07/11 Page 4 of 4 M FM AipprovaIr FM Approvals Member of the FM Global croV 1151 Boston -Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781762 4300 F: 781 762 9375 www.fmapprovals.com April 16,2012 Mr. Andy Lodge IKO Industries, Ltd. 40 Hansen Road South Brampton, Ontario L6W 3H4 Canada Subject: FM Approved Steep Slope Roofing Products listed in RoofNav Dear Andy: This letter is being written as a follow up to our telephone conversation of earlier today. Please be advised that the following shingles have been tested and Approved in accordance with FM Standard 4475 Approval Standard for Class 1 Steep Slope Roof Covers: IKO Industries Ltd.: Cambridge, Cambridge AR, Crowne Slate, Hip & Ridge 12, Marathon 25 AR, Marathon Ultra AR, Grandeur, and Leading Edge Plus Canroof Corp.: Biltmore, Biltmore AR, CRC Hip & Ridge 12, Superglass 25 AR, and Superglass Ultra AR These shingles are listed in RoofNav the on-line resource of FM Approvals as of April 16, 2012. RoofNav can be accessed at www.RoofNay.com If you have any questions please do not hesitate to contact me. Very truly yours, Dom, David L. Alves Senior Engineer - Materials Group FM Approvals T: 781 255 4856 F:, 781 762 9375 E:' david.alves(-,fmapprovals.com FM US VX APPROVED Phillip J. Smith, P.E., Asst. Vice President Technical Team Manager FM Approvals C E FM a, APPROVED FM Aipprovalse FM Approvals Member of Ae FM Gfoba! Gm1T 1151 Boston -Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781762 4300 F: 781762 9375 www.finapprovals.com March 1, 2012 Mr. Andy Lodge IKO Industries, Ltd. 40 Hansen Road South Brampton, Ontario L6W 3H4 Canada I Project ID: 3036971 Subject: Certification Letter for ASTM Testing of Various IKO Industries Ltd. and Canroof 1 Corporation, Inc. roof shingles Customer ID: 100000686 I I Dear Mr. Lodge: This letter is being written as a follow up to your request for documentation regarding testing performed thus far for the shingles. The table below includes the shingle name, manufacturing locations, most recent ASTM test procedures and the FM Approvals project Identification Number under which the tests were performed: i Shingle name: Leading Edge Hip & Ridge 12 Cambridge AR Marathon 25 AR Plus and CRC Superglass 25 AR Manufacturing IKO - Brampton, IKO - Brampton, Canroof - Toronto, IKO - Brampton, Locations: Canroof - Toronto IKO — Kankakee, Canroof - Toronto, IKO — Wilmington IKO - Hawkesbury I IKO-Hawkesbury, ASTM D 3161-06: Project: 3040947 Project: 3040947 Project: 3040947 Project: 3040947 ASTM D 3462-07: Project: 3041689 Project: 3041689 Project: 3041689 Project: 3041689 for Toronto, for Toronto, Kankakee and Kankakee and Wilmington Wilmington Project:3045254 Project:3045254 for Hawkesbury I for sbury ASTM E 108-07: 1 Project: 3010968 1 Project: 3010968 1 Project: 3010968 1 Project: 3010968 I . I FM FM � I ��( o C E APPROVEDAPPRoAPPROVEDPPROV . ., j A If you have any questions please do not hesitate to contact me. i Very truly yours, ."//Ll-r' David L. Alves Senior Engineer - Materials Group FM Approvals T: 781 255 4856 F: 781 762 9375 t: david.alvesafinaunrovals.com fMRpprouals- Member o/rhe FM Global Group Phillip J. Smith, P.E., Asst. Vice President Technical Team Manager FM Approvals