HomeMy WebLinkAboutSUBMITTED PAPERSa
Fee Due:
Q - . ?ermit #
13 Electrical
❑ Shed
Ptamtng & Development Services
Building & Code Regulations Dhdsion SC ,
230- Virginia Ave. gNN�G
Fort FL5982 St RUgC� C/o
SPECIALTY PERMIT APPLICATION
❑ Plumbing 10 JEVAC ❑ Pence
❑ Demolition ❑ Gas ❑ Siding
Seepage 2 for uzs uer' oms and udd dmal paperwork required for specialty permits
t. Location/Site Address: 3S c>
2. Parcel ID Number:
OJftce Use
only
Towasiup Rage
Section
MapP-ge
Zoairlg Laud Use
Initials
3. Complete Description of Project or Work Q (Ze R 1pe-ja- � ��-�,. C-'r
its t4 ` i` -t'" S (4L-
z LA
4. Owners Information 5. Cmatraetors Infarmataote
Name: �SL1,�j =�-%?, b'" ,rVJ,4QM
Address: 95 CkZ17C �) GIUD -KaLX5A
City: State: FL
Zip: Pho� LdjA f'
b. Value of Construction:? .
EL Rcg/Cert #: CAC` J;m (. (a) 9
County Cert#: QLDtoacn
Besiness Nalue:
Phone 1 -•,7A. 5 Fax:
OwNER,s AFFIDAVIT: I certify that all of the fi &ormation cmtained R this aWlicatmn is correct and chat all work will be done m
compliance with all applicable laws regulating zoning.
PRINTOWNEgPRCONTRACTORNAME SIGNATURE OF OWNER OR CONTRACTOR
STATE OF FLORIDA, COUNTY OF UC E� II
ACKNOWLEDGED_ b . BEFORE ME THIS DAY OF 2 �BY
WHO IS PERSONALLY KNOWN TOME OR WW HAS PRODUCED
IDEN NICATION
V► � �� REi
tate of Florida
SIG ATUREOF OTARY ORPRII+if NAMEOFNOTARY sselln EE038992
�COMMISSIONNUMBER 2014
NOTICE TO OWNER FAILURE TO RECORD A NOTICE OF COMWCEMEiM MAY RESULT IN YOUR PAYING TWICE FOR
IM1p80VEMWTS TO YOUR PROPERTY IF YOU INTEND TO OBTAIN FINANCM, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT. A/C -HEAT REPLACE16dEEVI' WrM C1iVMCT UNDER S750A
Revised 04/26/2010
This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
between Feb 17, 2009 and Dec 31, 2013.
Certificate of Product Ratings
AHRI Certified Reference Number: 5550388 Date: 12/4/2013
Product: SplitSystem: Air -Cooled Condensing Unit, Coil with Blower
Outdoor Unit Model Number: 14AJM25
Indoor Unit. Model Number: RHLL-HM2417+RCSL-H*2417
Manufacture ir; RHEEM SALES COMPANY, INC.
Trade/Brand name: RHEEM, RUUD, WEATHERKING Fit ie p
ir
Manufacturer responsible for the rating of this system combination is RHEEM SALES COMPANY, INC.
Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air -Conditioning and Air -Source
Heat Pump' Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
I
Cooling Capacity (Btuh): 24200
EER Rating (Cooling); 13.00
SEER Rating (Cooling): ' 16.00
IEER Rating (Cooling):
i.
* Ratings followed by an asterisk (*) Indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate
DISCLAIMER ,'
AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibllityfor,
the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the produd(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridiredoryRorg.
TERMS AND CONDITIONS
This Certificate and Its contents are proprietary products of AHRL This Certificate shall only be used for individual, personal and confidential reference purposes.
The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any
form or manner or by any means, except for the user's individual, personal and confidential reference.
CERTIFICATE VERIFICATION
The Information for the model cited on this certificate can be verified at www.ahridirectorycorg, A VIM' Air -Conditioning, Heating,
dick on "Verify Certificate" link and enter the AHRI Ceifified Reference Number and the date on 00 `' and Refrigeration Institute
which the certifi i to was Issued, which is listed above, and the Certificate No., which Is listed below.
02016 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130306814071936224
y� Project Summary- Job: 8520
Wf I ghtsoff Date: December 05 2013
Cooler By DesignEntire Ho use : I L E COPY By: Russell
Project Information
For. Snyfer Partners, Amtek Air Cond
3505Avenue F, S. Lucie County, FL
Phone: 954-658-8154
Notes: Email: 2shawnrussell@bellsouth.net
--Desiqn Information
Weather Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 43 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 27 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 15158 Btuh Structure 15121 Btuh
Ducts 2444 Btuh Ducts 5221 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 17602 Btuh Use manufacturer's data n
Rate/swing. multiplier 0_95
Infiltration Equipment sensible load 19325 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 1513 Btuh
Ducts 1068 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (W) 1050 1050 Equipment latent load 2582 Btuh
Volume (ft3) 9450 9450
Air changes/hour 0.45 0.23 Equipment total load 21907 Btuh
Equiv. AVF (cfm) 71 36 Req. total capacity at 0.70 SHR 2.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make n/a Make Rheem
Trade n/a Trade RHEEM 14AJM SERIES
Model n/a Cond 14AJ M25
AHRI ref n/a Coil RHLL-HM2417++RCSL-H*2417
AHRI ref 5550388
Efficiency, n/a Efficiency 13.0 EER, 16 SEER
Heating input 0 Btuh Sensible cooling 16940 Btuh
Heating output 0 Btuh Latent cooling 7260 Btuh
Temperature rise 0 OF Total cooling 24200 Btuh
Actual air flow 807 cfm Actual air flow 807 cfm
Air flow factor 0.046 cfm/Btuh Air flow factor 0.040 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.89
Bold/italic values have been manually ovenidden
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
t Wrl htSOft" 2013-Deo-0512:21:22
9 RightSuite® Universal 2013 13.0.08 RSU09070 Page 1
AMIk CAUsers\Shawn\Documents\AC LOADS\1050 SQ FT.rup Calc = MJ8 Front Door faces: NE