Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE FILED. PLAN REVIEW FEE: RECEIPT NO.: PERMIT NUMBER: 140 D I 54 CONCURRENCY FEE: RECEIPT NO.: CERT. CAP. NO.: ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION , L 2300 Virginia Avenue O 4 - O I T Ft. Pierce, FL 34982-5652l�� C (� 1 {� 772-462-1553 APPLICATION for BUILDING PERMIT CERTIFICATE of CAPACITY/ZONING COMPLIANCE PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: ze-6-rW A / 2. PROJECT NAME: &JA x SITE PLAN NAME: 3. PROPERTY TAX ID #: 2 y 3 3^ (o O l- 0 0 8?- D 0 40 4. LEGAL DESCRIPTION (attach extra sheets if necessary): 5 (;.tom' 1E J W dQ i S 12 5. PLAT BOOK 6. PAGE NO. 7. BLOCK NO. 8. LOT NO. 9. PARCEL SIZE (ACRES/SQ FT.): Z- Al, - LOT DIMENSIONS: 10, COMPLETE DESCRIPTION OF CONSTRUCTION PROJECT OR WORK ACTIVITY: -DO C,K— (8-A L14) non bo of 1 14f 11. SETBACKS (ACTUAL) FRONT:l J BACK: fJ?q RIGHT SIDE: N A LEFT SIDE: 1A 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) [ ] NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ ] INTERIOR RENOVATION [ ] RESIDENTIAL [ ] .COMMERCIAL [ ] INDUSTRIAL OTHER (SPECIFY) A %' F P z c- 1- r-a tdi l t Xy 13. DESCRIPTION OF PROPOSED USE: R cs i t>;Et'37 t A L 14. SO. FT OF CONSTRUCTION: �� `O 15. SF. FT 1 st FLOOR: 16. VALUE OF CONSTRUCTION: $ % 01 0 0 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. if the valuc is $2500 or more, a RECORDED Notice ofCommcneement must be submitted with this application. SLCCDV Form No.: 001-02 SCANh%,E.D) BY' St. Lucie County; UPDMED 6/25/09 OWNER INFORMATION -7 96, 303 q37V-.2 dea #X,2e_. NAME: 'B i ADDRESS: U- j a I -r CITY: I)q 1 STATE: zip: 3 313 PHONE (DAYTIME): S-700 Email: (,-JAx<P XAJP-KC0tA,C00 IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: PHONE (DAYTIME): (__) CONTRACTOR INFORMATION ST. of FL REG.CERT #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): C_) STATE: 0 W w4uVI.— / 13 Q � t--mrz'--z' STATE: FAX NO. ST. LUCIE COUNTY CERT #: Email: ZIP: 0 ARCI-HT/ENGINEER- ?AQ t4 ADDRESS: -A I k4 CITY: STATE: ZIP: PHONE (DAYTIME) BONDING COMPANY: ADDRESS: CITY: MORTGAGE LENDER. ADDRESS: CITY: STATE: STATE: ZIP: ZIP: IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days after notification it will be voided and returned to you by mail. CERTIFICATION: This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, FENCES, ETC., not otherwise included with this building permit application. St. Lucie County makes no representation that its granting of a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Homeowner Association rules, bylaws or any covenants that may restrict or prohibit such structure. Please consult with your Homeowner's Association and review your deed for any restrictions which may apply. The following building permit applications are exempt from undergoing a full concurrency review. room additions, accessory structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: YOUR FAILURE TO RECORD A,NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOBSITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT: AS A CONDITION OF ISSUANCE OF THIS PERMIT, YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. r- OWNE R C CTOR SIGNATURE STATE OF FLORIDA COUNTY OF iT L-•U C. I The foregoing instrument was acknowledged before me this T day of i' 20 by who i`s_personally known ' * �o/r1has produced L4 W ZOO goVJ 5�Q �'�i' "(U as identification. Signature of Notary CONTRACTOR SIGNATURE STATE OF FLORIDA COUNTY OF The foregoing instrument was acknowledged before me this day of by 20 , who is personally known or has produced Signature of Notary as identification. ...........,""....". 'w P(blic - State of Flonaa — '� My Comm. Expires Jul 29.2014 '-� Commission # DID 996746 . •'.; E ,;• •' Bonded Through National Notary Assn. NOTE: TWO (2) SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION. OWNER BUILDER AFFIDAVIT WILL BE REQUIRED FOR ALL OWNERBUILDER APPLICANTS. ' For specific inptructions see appropriate permit 5' hecklist 4 OFFICE USE ONLY - 'V: SECTION TOWNSHIP RANGE MAP NO. ZONING LAND USE LOT CVG % TAZ NO. FLOOD ZONE FIRM MAP # 1"�" FLR ELV MAX HGT CONST TYPE OCCUP TYPE MAX OCCUP # OF FLRS WATER SEWER SPRINKLERS STORMWATER LOT OF REC Before 1/1990 LOT OF REC After 1/1990 LOT SPLIT REQUIRED LOT SPLIT APPROVED REPORT HABITABLE RADON PERMIT CODE AREA FEE FEE (RADON) LIBRARY PUBLIC BLD PUBIC BLD PARKS .IMPACT IMPACT FEE IMPACT IMPACT :FEE CORRECTION FEE FEE GENERAL :SCHOOL ROAD CREDIT Y N LAW ENF IMPACT IMPACT IMPACT FEE FEE FEE FIRE/EMS DRIVEWAY Y N DRIVEWAY ADMINISTRATIVE IMPACT REQUIRED FEE VARIANCE FEE FEE SPECIFY MECHANIC ROOF NON -CONFORMING MISCELLANEOUS SUBS ELECTRIC GAS LOT OF RECORD FEES REQUIRED PLUMBING FEES DATE SENT TO ADDRESSING: REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW kTE ?CEIV-ED ATE ---- --/---- IiAPT T7W-n # i I 1 4 1 i I i I i i ti y j i I I 1 Planning & Development Services Department Building & Code Regulations. 2300 Virginia Avenue Fort Pierce, Florida 34982 (772) 462-1553 . OWNER/BUILDER AFFIDAVIT DISCLOSURE STATEMENT F.S. 489.103 (7) EXEMPTIONS State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You may build or improve farm outbuildings, a one -family or two-family residence or a commercial building at a cost of under $75,000.00. The building or residence must be for your own occupancy. It may not be built or substantially improved for sale or lease. If you sell or lease a building you have built or substantially improved your self within one year after the construction is complete, the law will presume that you built or substantially improved it for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building; it is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who is not licensed must work under your direct supervision and must be employed by .you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all appli le laws, ordinances, building codes, and zoning regulations. Initial I understand that the building official and inspectors are not there to design or give advice on ho3N7o meet the minimum code. Initial I understand that as an owner -builder that any contract disputes with sub -contractors and I must be handled in a civil court with the advice of an attorney. This department will not mitigate any contract disputes. Initial �q_ I understand that if I compensate any person or company for work performed they are required to be licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and liaW for the cost of the license. Initial I understand that if any person that is unlicensed and uninsured gets injured on my construction roject- they may be entitled to workmen's compensation. I could be held liable for. all doctor, lawyer and relate edical cost, which could include loss of wages during recovery from their injury. Initial To qualify for this exemption under this subsection, an owner must personally appear and sign a building permit application and initial the above. I hereby acknowledge that I have read and understand the above disclosure statement and that I finther understand that any violation of the terms of the owner/builder exemption shall be reported by the Building and Zoning Department to the Florida State Department of Professional Regulation. Signed and acknowledged on this /S dayof SAN1j9Q.yof20tLf . Owne W.1der 1 ature —STATE-OF FL-ORIDA - - COUNTY OF St I�U, ILI L I The foregoing instrument acknowledged before me this 14 day oAJ 20 J L by kQ1tJ1QwQ who is personally known to , or who has produced 2 0® 9 2 5' S 4 `i O as identification. Signature of Notary Type or Print Name of Notary (Seal) Title: Notary Public Commission Number - SLCPDSD Revised 07/22/2010 •`�a•"y ��., IRVIE E SAUNDERS s'aP��`4� Notary Public - State of Florida My Comm. Expires Jul 29, 2014 Commfaelon # DD 998746 "` Bonded Through National Notary Assn. OFFICE USE ONLY: DATE FILED: i 1 REVISION FEE: 1. LOCATION/SITE ADDRESS: PERMIT # RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982,5652 (772) 462-1553 FAX (772) 462-1578 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION t- i t G rac,ti L 3�fR81 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: 3. MOVE Dock CONTRACTOR INFORMATION. STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: ST. LUCIE COUNTY CERT. #: CITY: STATE: PHONE (DAYTIME): FAX: 4. OWNER/BUILDER INFORMATION: NAME: W FS ADDRESS: CITY: PHONE:�- STATE: �F e` FAX: ---5.-- -- ARCHITECT -/ENGINEER INFORM-ATION: — NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME): Revised 07/22/2014 l • tt i Y FAX: ZIP: ZIP: s q 9 $ ( ZIP: C 1 FLORIDA DEPARTMENT OF RICK SCOOT' GOVERNOR ENVIRONMENTAL PROTECTION CARLOS LOPEZ-CANTERA SOUTHEAST DISTRICT BRANCH OFFICE LT. GOVERNOR 337 N US HIGHWAY 1, SUITE 307 FORT PIERCE, FL 34950-4255 HERSCHEL T. VINYARD JR. (772) 467-5500 SECRETARY - /B�I,D/ING DIVISION July 3, 2014 ST. L COUNTY IEVIEWED FOR CO LYANCE William. Wax REVIEWED BY _ 2280 Sweetwater Drive . DATE ST gE Is�IPT 01 JOB Fort Pierce, FL 34981 pLANS AND'PEItlatiT WII. L .BE MADE. No ViSPECTION Sent via:e-mail: B:wax@waxcom.com OR Re:' File No.: 56-0327039-001 File Name: Wax, William KM "'OPY: Dear Mr. Wax: - On June 6, 2014, we received your application for an exemption to extend an. existing 168 sq.ft. marginal dock by adding an irregular :shaped 5�4 sq.ft. marginal dock addition for a total dock square footage of 702 sq.ft: The project is located in the North Fork of the St. Lucie River, Class III Waters, adjacent to 2280 Sweetwater Drive, Fort Pierce (Section 33, Township 35 South, Range 40 East), in St.. Lucie County (Latitude: N 2723' 33.29", Longitude W 80020' 51.69"). Your request has been reviewed to determine whether it meets the requirements for any of three kinds of authorization that may be necessary for work in wetlands or waters of the United States. The kinds of authorization are (1) regulatory authorization, (2) proprietary authorization .(related to state-owned submerged lands), and (3) federal authorization. The authority for review and the outcomes of the reviews are listed below. Please read each section carefully. Your project may not have qualified. for all three forms of authorization. If your project did not qualify for one or more of the authorizations, refer to the specific section dealing with that authorization_ for advice on how to obtain it. 1. Regulatory Review - VERIFIED Based on the information submitted, the Department has verified that the activities as proposed are exempt, under Chapter 62-330.05l (5)(b),-Florida Administrative Code, from the need to obtain a regulatory permit under part IV of Chapter 373 of the Florida Statutes. - This exemption verification is -based -on -the -information -you -provided -the -Department and -the - statutes and rules in effect when the information was submitted. This verification will expire after one year, and will not be valid at any other time. if site con'nditions materially change, the project design is modified, or the statutes. or rules governing .the exempt activity ,are amended. However, the activity may still be conducted without further notification to or verification from the Department after the one-year expiration of this verification, provided: 1) the project design does not change; 2) site conditions do not materially change; and 3) there are no changes to the statutes or rules governing the exempt activity. In the event you need to re -verify the exempt status for the www.dep.state flits File No.: 56-0327039-001 File Name: Wax, Wiliam Page 2 of 4 activity after the one-year expiration of this verification, a new application and verification fee will be required. Any substantial modifications to the project design should be submitted to the Department for review, as changes may result in a permit being required. Conditions of compliance with the. regulatory exemption are contained in Attachment A. 2..: Proprietary Review. — GRANTED The Department acts as staff to the Board 'of Trustees of the Internal Improvement Trust:Fund (Board of Trustees) and issues certain authorizations for the use of sovereign submerged lands. The Department has the authority to review activities on sovereign submerged lands under chapters 253 and 258 of the Florida Statutes, and chapters 18-20 and :18-21 of the Florida Administrative Code. The activity may be located on sovereign submerged lands owned by the Board of Trustees.. The activity is not exempt from the need to obtain the applicable proprietary authorization. As staff: to the Board of Trustees, the Department has reviewed the activity described above, and has determined that the activity qualifies for an automatic consent of use by rule under rule 18- 21.005(1)(b) and section 253.77 of the Florida Statutes to construct and use the activity on the specified sovereign submerged lands, as long as the work performed is located within the boundaries as described herein and is consistent with the terms and conditions herein. No. further application is required for this consent of use. General Conditions for State -Owned Submerged Land Authorizations: (a) -Authorizations are valid only for the specified activity or use. Any unauthorized deviation from the specified activity or use and the conditions for undertaking that activity or use shall constitute a violation. Violation of the authorization shall result in suspension or revocation of the grantee's use of the sovereignty submerged land unless, cured to the satisfaction of the Board. (b) Authorizations convey no title to sovereignty submerged land or water column, nor do they constitute recognition or acknowledgrnent of any other person's title to such land or water. (c) Authorizations may be modified, suspended or revoked in accordance with their terms_ or the remedies provided in Sections 253.04 and 258.46, F.S., or Chapter 18-14, F.A.-C. (d)-Structures or activities shall be constructed and used to avoid or minimize adverse impacts to sovereignty submerged lands and resources. (e)-Construction,-use,-or-operation-of_the structure or_activity shall not adversely affect any species which is endangered; threatened or of special concern, as listed in Rules 68A-27.003, 68A-27.004, and 68A-27.005, F.A.C. . (f) Structures. or activities shall not unreasonably interfere with riparian rights. When a court of competent jurisdiction determines that. riparian rights have been unlawfully affected, the structure or activity shall be: modified in accordance with the court's :decision. (g):Structures or activities shall not create a navigational hazard.: t File No.: 56-0327039-001 File Name: Wax,, Wiliam Page 3 of 4 (h) Structures .shall be maintained. in a functional condition and shall be repaired or removed if they become dilapidated to such an extent that they are no longer functional. This shall not :be construed to prohibit the repair or replacement subject to the provisions of Rule 1 &21.005, F.A.C., within one year, of a structure damaged in a discrete event such as a storm, flood; accident, or fire. (i) Structures or activities shall_ be constructed, operated, and maintained solely for :water dependent purposes, or for non -water dependent activities authorized under paragraph 18- 21.004(1)(f), F:A.C., or any other applicable law.. 3. SPGP Review _ APPROVED Authority for review - an :agreement with the USACOE entitled: "Coordination Agreement Between the U. S. Army Corps of Eiigineers (Jacksonville District) and the Florida Department. of Environmental Protection, or Duly Authorized Designee, State: Programmatic General Permit", Section 10 of the Rivers and Harbor Act of 1899, and Section 404 of the Clean Water Act. Your proposed activity as outlined on your application and attached drawings qualifies for Federal authorization pursuant to the State Programmatic General Permit IV-R1, and a SEPARATE permit or authorization: will notbe required from the Corps. Please .note that the, Federal authorization expires on July 25, 2016.. You, as permittee,, are required to adhere to all General Conditions and Special: conditions that may apply to .your project." A copy of the SPGP IV=R1 with all terms and conditions -.and the General Conditions may be found at htty:%/wWw.sai.usd6e.aimv.mil/Divisions/Reaulatbrv/soiirc6book.htm. Additional Information This letter does not relieve you from the responsibility of obtaining other federal, state, or local authorizations that maybe required for the. activity. Please retain this letter. The activities may be inspected by authorized state personnel in the future to insure compliance with appropriate statutes and administrative codes. If the activities are not in compliance, you may be subject to penalties under Chapter 373, F.S., and Chapter 18-14, F.A.C. If you have any questions, please contact. Mary Zavash at (772) 467-5566 or by email at Mary.Zavash@dgp.state.fl.us: When referring to your:project; please use.the FDEP file name and number listed above. --Executed in -Palm- Beach -County, -Florida. — -- File No.: 56-0327039-001 File Name: Wax, Wiliam Page 4 of 4 STATE OF FLORIDA DEPARTMENT OF. ENVIRONMENTAL PROTECTION Benny Luedike Environmental -Manager_ Submerged Lands and Environmental Resource Program . Enclosures: Notice of Rights Attachment A- Specific Exemption Rule Attachment B- Newspaper Publication Special Conditions for use of the SPGP Conditions Project Drawings, 3 pages Copies furnished'to- USACOE- Palm Beach=Gardens, FDEP-SP@usace.al.M.mil Bruce Jerner, Jerner & Associates, Inc., jerner@bellsouth.net FILING AND ACKNOWLEDGMENT FILED, on this date, pursuant to 120.52(9), Florida Statutes, with the designated Department Clerk, receipt of which is hereby acknowledged. Clerk Date NOTICE OF RIGHTS This action is final and effective on the date filed with the Clerk of the Department unless a petition for an administrative hearing is timely filed under Sections 120.569 and 120.57, F.S., before the deadline for filing a petition. On the filing of a timely and sufficient petition, this action will not be final and effective until further order of the Department. Because the administrative hearing process is designed to formulate final agency action, the filing of a petition means that the Department's final action may be different from the position taken by it in this notice. Petition -for Administrative Hearing-. A person whose substantial interests are affected by the Department's action may petition for. an administrative proceeding (hearing) under Sections 120.569 and 120.57, F.S. Pursuant to Rule 28- 106.201, F.A.C., a petition for an administrative hearing must contain the following information: (a) The name and address of each agency affected and each agency's file or identification number, if known; (b) The name, address, any email address, any facsimile: number, and telephone number of the. petitioner; the name; address, and telephone number. of the :petitioner's representative, if any, which shall be the address for service purposes during the course:of the proceeding; and an explanation of how the petitioner's substantial interests are or will be affected by the agency determination; (c) A statement of when and how the petitioner received notice of the agency decision; (d) A statement of all disputed issues of material fact. If there are none; the petition must so indicate; (e) A concise statement of the ultimate facts alleged, including the specific facts that the petitioner contends marrant reversal or modification of the agency's proposed action; (f) A statement of the specific rules or statutes that the petitioner contends require reversal or modification of the agency's proposed action, including an explanation of how the alleged facts relate to the specific rules or statutes; and (g) A statement of the relief sought by thepetitioner, stating precisely the action that the petitioner wishes the agency to take with respect to the agency's proposed action. The petition must be filed (received by the Clerk) in the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000. Also, a copy of the petition shall be mailed to the applicant at the address indicated above at the time of filing Time Period for Filing a Petition In accordance with Rule 62-110.106(3), F.A.C., petitions for an administrative hearing by the - - applicant -must -be -filed -within 21-days--of-receipt-of this -written -notice. -Petitions-filed-by-any-- - persons other than, the applicant, and other than, those entitled to written notice under Section 120.60(3), F.S. must be filed within 21 days of publication of the notice or within 21 days of receipt of the written notice, whichever occurs first. Under Section 120.60(3), F.S., however; any person Who has asked the Department for notice of agency action may file a petition within 21 days of receipt of such notice, regardless of the: date of publication. The failure to file a petition within the appropriate time period shall_ constitute a waiver of that person's right to request an administrative determination (hearing) under Sections 120.569 and 120.57, F.S.; or to intervene in this proceeding and participate as a party to it. Any subsequent intervention (in a proceeding initiated by another party) will be only at the discretion of the presiding officer upon the filing. of a motion in compliance with Rule 28-106.205, F.A.C. Extension of Time Under Rule 62-110.106(4), F.A.C., a'person whose substantial interests are affected by the Department's action may also request an extension of time to file a petition for an administrative hearing. The Department may, for good cause shown, grant the request for an extension of time. Requests for extension of time must be filed with the Office of General.Counsel of the Department at 3900 Commonwealth Boulevard,. Mail Station 35, Tallahassee, Florida 32399-3000, before the applicable deadline for filing a petition for an administrative hearing. A timely request for extension of time shall toll the running of the time period for filing a petition until the request is acted upon. Mediation Mediation is not available in this proceeding. FLAWAC Review The applicant, or any party within the meaning of Section 373.114(1)(a) or 373.4275, F.S., may also seek appellate review of this order before the Land and Water Adjudicatory Commission under Section 373.1.14(1) or 373.4275, F.S. Requests for review before the Land and Water AdjudicatoryCommission must be filed with the Secretary of the Commission and served on the Department within 20 days from the date when the order is filed with the Clerk of the:Department. Judicial Review Any party to this action has the right to seek judicial review pursuant to Section 120.68, F.S., by filing a Notice of Appeal pursuant to Rules 9.110 and 9.190, Florida Rules of Appellate Procedure, with the Clerk of the Department in the Office of General Counsel, 3900 Commonwealth Boulevard, M.S. 35, Tallahassee, Florida 32399-3000; and by filing a copy of the Notice of Appeal accompanied by the applicable filing fees :with the appropriate District Court of Appeal. The Notice of Appeal must be filed within 30 days from the date this action is filed with the Clerk of the Department. i Attachment A Chapter 62-330.051 ExemptActivities. The activities meeting the limitations and restrictions below are exempt from permitting. However, if located in, on, or over state-owned submerged lands, 'they are subject to -a separate authorization under Chapters 253 and 258, F.S., and Chapters 18-18, 18-20, and 18-21, F.A.C., as applicable. (5): Dock, Pier, Boat Ramp and Other Boating-related.Work — . (b) Installation of private docks,,:piers, and, recreational docking facilities, and installation of local governmental piers and recreational docking facilities, in accordance with Section 403..813(1)(b), F.S. .This includes associated structures such as boat shelters, boat lifts, and roofs, provided: 1. The cumulative square footage: of all structures located over wetlands and -other surface waters.'' does not exceed the limitations in Section 403.813(1)(b); F.S.; 2. No structure is enclosed on more than three sides with walls and doors; 3. Structures. are not used for residential habitation or commercial purposes, or storage of materials other than those: associated with water dependent recreational use; and 4. Any dock and associated structure shall be the sole dock as measured along the shoreline for a .minimum. distance of 65 feet, unless.the parcel of land or individual lot as platted is less than 65 feet in length along the shoreline; in which case there may be one exempt dock allowed per parcel or lot. Attachment B STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION NOTICE OF DETERMINATION OF EXEMPTION File No.: 56-0327039-001. The Department of Environmental Protection gives notice that the project to extend an existing 168 sq.ft. marginal dock by adding an irregular shaped 534 sq.ft. marginal dock addition for a total dock square footage of 702 sq.ft. has been determined to be exempt from requirements to obtain an Environmental Resource Permit. The project is located in the North Fork of the St. Lucie River, :Class III Waters, adjacent to 2280 Sweetwater Drive, Fort Pierce (Section 33, Township 35 South, Range 40 East), in St. Lucie County (Latitude N 27° 23',33.29", Longitude W 80- 20' 51.69"). . A person whose substantial interests'are affected by the Department's action may petition for an administrative proceeding :(hearing) under sections 120.569 and 120.57 of the Florida Statutes. The petition must contain the information set forth below and -must be filed (received by the clerk) in the Office of General -Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000. Mediation is not. available. If a timely. and sufficient petition for an administrative hearing is filed, other persons whose substantial interests will be affected by the outcome of the administrative process have the right to petition to intervene in the proceeding. Intervention will be permitted only at the discretion of the presiding officer upon the filing of a motion incompliance with rule 28-106.205 of the Florida Administrative Code. In accordance with rule 62-110.106(3), F.A.C., petitions for an administrative hearing must be filed within 21 days'of publication of the notice or receipt of written notice, whichever occurs first. Under rule 62-110.106(4) of the Florida Administrative Code, a person whose substantial interests are affected by the Department's action may also request an extension of time to file a petition for an administrative hearing. The Department may, for good cause shown, grant the request for an extension of time. Requests for extension of time must be filed with the Office of General Counsel of the Department at.3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000 prior to the applicable deadline. A timely request for extension of time shall toll the running of the time period for filing a petition until the request is acted upon. Upon motion by the requesting parry showing that the failure to file a request for an extension of time before the deadline was the result of excusable neglect, the Department may also grant the requested extension of time. The petitioner shall mail a copy of the petition to the applicant at the address indicated above at the time of filing. The failure of any person to file a petition for an administrative hearing within the appropriate time period shall constitute a waiver of that right. A petition that disputes the material facts on which the Department's action is based must contain the following information: (a) The name and address of each agency affected and each agency's file or identification number, if known; (b) The name,'address, and telephone number of the petitioner; the name, address, and telephone number of the petitioner's representative; if any, which shall be the address for service purposes during the course of the.proceeding; and an explanation of how the petitioner's substantial interests are or will be affected by the agency determination; (c) A statement of when and how the petitioner received notice of the agency decision; (d) A statement of all disputed issues of material fact. If there are none, the petition must so indicate; (e) A concise statement of the ultimate facts alleged, including the specific facts the petitioner contends warrant reversal or modification of the agency's proposed action; (f) A statement of the specific rules or statutes that the petitioner contends require reversal or modification of the agency's proposed action; and (g)- A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wishes the agency to take with respect to the agency's proposed action. _ — A petition that does not dispute the material -facts -on -which -the -Department's action -is based -shall -state_ -that no -such -facts -are — - in, dispute and otherwise shall contain the same information as set forth above, as required by rule 28-:106.301. - Under sections 1.20.569(2)(c) and (d) of the Florida Statutes, a petition for administrative hearing shall be dismissed by the agency if the petition. does not substantially comply with the above requirements or is untimely filed. Complete copies of all documents relating to this determination of exemption are available for public inspection during normal business hours, 8:00 a.m. to 5:00 p.m., Monday through Friday, at the Southeast District office, 400 North Congress Avenue, 31 Floor, West Palm Beach, Florida 33401. SPECIAL CONDITIONS FOR USE OF THE SPGP IV-Rl 1.. The District Engineer reserves the right to require that any request for authorization under this general permit be evaluated as an Individual Permit. Conformance with the terms and conditions of the SPGP IV- Rl does. not automatically guarantee authorization. 2. No activity is authorized under the SPGP IV-Rl which may impact a federally listed threatened or endangered, species or a species proposed for such designation, or its designated critical habitat. 3. On a case -by -case basis the Corps may impose additional special conditions which are deemed necessary to minimize adverse environmental impacts. 4. Failure to.comply with all conditions of the Federal authorizations under the SPGP IV- Rl would constitute a violation of the Federal authorization. 5. The SPGP IV-R1 is not applicable .in the geographical boundaries of. Monroe County; the Timucuan Ecological and Historical Preserve :(Duval County); the St.:Mary's River, from its headwaters to its confluence with the Bells River; the Wekiva River from its confluence with the St. Johns River to Wekiwa Springs, Rock Springs Run from its headwaters at Rock Springs to the confluence with the Wekiwa Springs Run, Black Water Creek from the outflow from.Lake Norris to the confluence with the Wekiva River; canals at Garfield Point including Queens Cove (St. Lucie County); the Loxahatchee River from Riverbend Park downstream to Jonathan Dickinson State Park; the St. Lucie Impoundment (Martin County); all areas regulated under the Lake Okeechobee and Okeechobee Waterway Shoreline Management Plan, located between St. Lucie Lock (Martin County) and W.P: Franklin Lock (Lee. County); American Crocodile designated critical habitat (Miami -Dade and Monroe. Counties); Johnson's seagrass designated critical habitat (southeast Florida); piping plover designated critical habitat (throughout Florida); acroporid coral designated critical habitat (southeast Florida); Anastasia Island, Southeastern, Perdido Key, Choctawhatchee, or St. Andrews beach mice habitat (Florida east coast and panhandle coasts); the Biscayne Bay National Park Protection Zone -(Miami -Dade County); Harbor Isles (Pinellas County); the Faka Union. Canal (Collier County); the Florida panther consultation area (Southwest Florida), the Tampa Bypass Canal (Hillsborough County); canals in the Kings Bay/Crystal River/Homosassa/Salt River system (Citrus County); Lake Miccosukee (Jefferson County). 6. No structure or work shall adversely affect or disturb properties listed in the National Register of Historic Places or those eligible for inclusion in the National Register. Prior to the start of work, the Applicant/Permittee or other party on the Applicant's/Permittee's behalf shall conduct a search of known historical properties by contracting a professional archaeologist, contacting the Florida Master Site File at 850-245-6440 or SiteFile@dos.state.fl.us. The Applicant/Permittee can also research sites in the National Register Information System.(NRIS). Information can be found at http://www.cr.nps.gov/nr/research%. If, during the initial ground disturbing activities and construction work; there are archaeological/cultural materials unearthed (which shall include, but not be limited to: pottery, modified shell, flora, fauna, human remains, ceramics; stone tools or metal implements, dugout canoes or any other physical remains _ that could be associated with Native- American cultures or early colonial or American settlement), the permittee shall immediately stop all work in the vicinity and notify the Compliance and Review staff of the State Historic Preservation Office at 850-245-6333 -and the Corps Regulatory Project Manager to assess the significance of the.discovery and devise appropriate actions, including salvage operations. Based, on the circumstances of the discovery, equity to all parties, and considerations of the public interest; the Corps may modify, suspend or revoke the permit in accordance with 33 CFR Part 325.7. In the unlikely event that human remains are identified, they will. be treated in accordance with Section 812.05, Florida Statutes; all work in the vicinity shall immediately cease and the local law authority, the State Archaeologist (850-245-6444), and the Corps Regulatory Project: Manager shall immediately be notified. Such activity shall not resume unless -specifically authorized by the State Archaeologist and the Corps. 7. No work shall be authorized under the SPGP IV -RI which proposes the use of prefabricated modules for habitat creation, restoration, or enhancement. 8. No activity shall be authorized under the SPGP IV-Rl which by its size or location may adversely impact water quality, fish and wildlife habitat, wetlands, or emergent or submerged aquatic vegetation. Where aquatic vegetation is present adverse impacts to aquatic vegetation from construction of piling -supported structures may be avoided/minimized by adherence to, or employing alternative construction techniques that provide a higher level of protection than, the protective criteria in the, joint U.S. Army Corps of Engineers'/National Marine Fisheries Service's "Construction Guidelines in Florida for Minor Piling- Supported.Structures Constructed in or over Submerged Aquatic Vegetation (SAV), Marsh or Mangrove Habitat U.S. Army Corps of Engineers/National Marine Fisheries Service August 2001." (See http://www.sai.usace.army.niil/Divisions/Regulatory/sotircebook.htm) Unless otherwise specifically approved by the National Marine Fisheries Service, where aquatic vegetation is present, piling -supported structuresauthorized under the SPGP IV-R1 must comply with, or provide a higher level of protection than, .the criteria contained in the referenced construction guidelines. Additionally, because of concerns about adverse impacts to the endangered Johnson's seagrass (Halophila johnsonii), piling -supported . structures in the lagoon (as well as canal) systems on Florida's east coast from Sebastian Inlet (Brevard County) south to and including central Biscayne Bay (Miami -Dade County) must also comply with, or provide a higher level of protection than, the criteria contained in the construction guidelines titled "Key for Construction Conditions for Docks or Other Minor Structures Constructed in or Over Johnson's seagrass (Halophila johnsonii) National Marine Fisheries Service/U.S. Army Corps of Engineers - February 2002." (See http://vvww.sai.usace.army.mil/Divisions/Regulatorv/sourcebook.htm) Note: Both of the Construction Guidelines may be subject to revision at any time. It is our intention that the most recent version of this technical tool will be utilized during the evaluation of each Department of the Army permit application. 9. Prior to issuance of authorization, the dichotomous key titled "The Corps of Engineers, Jacksonville District, and the State of Florida Effect Determination Key for the Manatee in Florida," dated March 2011, will be used to determine potential manatee impacts. All projects determined to be "may affect" and certain multi -slip facilities determined to be "may affect, not likely to adversely affect" will be sent to the Corps for consultation with the U.S. Fish and Wildlife Service in accordance with the Endangered Species Act. Note: The manatee key may be subject to revision at any time. It is our intention that the most recent version of this technical tool will be utilized during the evaluation of each Department of the Army permit application. The current version can be found on the Jacksonville District Regulatory Home Page at: htti)://www.sai.usace.ar my.mil/Divisions/Regulatory/sourcebook.htm 10. For projects in waters accessible to sea turtles, Small tooth sawfish, Gulf sturgeon, or Shortnose sturgeon, the permittee will utilize the "Sea Turtle and Small tooth Sawfish Construction. Conditions" (see http://www.saj.usace.army.mil/Divisions/Regulatorv/sourcebook.htm) and any added requirements, as . appropriate for the proposed activity. Note: These conditions may be subject to revision at any time. It is our intention that the most recent version of these conditions will be utilized during the evaluation of the permit -application.=- -_- 11. With respect to bald eagles, the permittee .should refer to the U.S. Fish and Wildlife Service's "National Bald Eagle Management Guidelines," dated May 2007 (see http://www.fws.gov/northflorida/BaldEagles/bald- eagles.htm) for guidance and clearance. Note: The preceding should be considered an interim condition, after which, new rules may be promulgated. It is the Corps' intention that the most recently approved version of these conditions or ensuing rules will be utilized during the evaluation of permit applications under this general permit. 1 12. For projects authorized -under this SPGP IV-Rl in navigable waters of the U.S.; the permittee understands and agrees that, if future operations by the `United. States require the removal, relocation, or other alteration, of the structures or work herein authorized, or if, in the opinion of the Secretary of the Army or his authorized representative, said structure or work shall cause unreasonable obstruction to the free navigation of the navigable waters, the permittee will be required, upon due notice from the Corps of Engineers, to remove, relocate, or alter the structural work or obstructions caused thereby, without expense to the United States. No claim shall be:made against the United States on account of any such removal or alteration. 13. The SPGP IV-Rl will be valid for five years from the date of issuance unless suspended or revoked by issuance ofA public notice by the District Engineer. The Corps, in conjunction with the Federal resource agencies, will conduct periodic reviews to'ensure-that continuation of the pemmit during the five-year. authorization :period is not contrary to the public interest. If revocation occurs, all future _applications: for activities covered by the SPGP IV-R1 will be evaluated by the Corps. . 14. If the.SPGP IV-R1 expires or is revoked prior to completion of the authorized work, authorization of activities which have commenced or are under contract to commence in reliance upon the SPGP IV-Rl will remain in effect provided the activity is completed within 12 months of the date the SPGP IV-R1 expired -or was revoked. 15. The General conditions attached hereto are made a part of this permit and must be attached to all authorizations processed. under this permit. BY AUTHORITY OF THE SECRETARY OF THE ARMY: Alfred A. R . taro, Jr. . Colonel, U.S. Army District Engineer pigior ro'CIO Rtd — i ;N °Revefg Ln'-= Bev Smith;7a,+ota,� : _ `'`. ) -iI ._, �_ ,-�,-- Skylark.®rJ'� N II ar , t;Fid_ V z. — -- _ --SIP-eve _ M. vA Ten V eeksi. f'° Whi#e Cii IIa K' ','.E7 FaithBapti f drool, ,i_ , P b 80'$W@dwbter'Dr._O 0 1r i. } FartlF��ercetCentral - { f Wgf`School - n II. I {. =Serenity Clr N : -v � ' �i 1 > �� � 1—_ °, � _�, 4 1 �• ��' � fie• �y �- I � ' � I I , _ r—�--� r"Paf w i} = a , if <•?? i r: I li 1 L..l_� �,,• �,. .,® �_ � ---, _ nrtcblin-Kflri-- ! B1b1e.B®�ti'st..Cliurch. d - I r— 5 -- _; 1.:NMEgret l{ve— , !' b ei, Q -Heron'Aye._ a), =.Ibis Ave_, Bg9itilBPutUf,'e l i Jerner &Associates, Inc. SHEET 1 Environmental Consulting ". Date: 5129114 2280 SWEETWATER DRIVE ; 2537SFAIfonso Ave. Port St. Lurie, FL34952 Ph.(772)283-2950 FT PIERCE ,f JERNER@BELLSOUTHNET i NORTH FORK EXISTING DOCK = 168 SQ FT ST LUCIE RIVER PROPOSED: DOCK = 534 SQ FT 80' WIDE. TOTAL = 702 SQ FT EXISTING DOCK & FLOATING LIFT PROPOSED DOCK ADDITION •---•- - - -•-•-- STEP UP A 21' 8, F.._.._.._.._..•_.,_. z iMHW _ - 35" ail200+' SHORELINE aoj fit. LW: i C;r . 4; BARREN SHORELINE a' Date intit ;r•: M� ' LOAK/ CABBAGE PALM A �OQ CANOPY THROUGHOUT Q .. . 1� � � q G. o � � 924 n p ►i u+ tTi b z y: N o N b' r _.._.._. _... A . lA' 3 1"=30' WAX Jerner&Associates, Inca SHEET 2 j ( Environmental Consulting Date: 614114 2280 SWEETWA TER DRIVE ; 2537SEAlonso Ave. Port St. Lucie, FL34952 Ph.(M)283-2950 FT PIERCE rr JERNER@BELLSOLITH.NET - Pier Section Thru Pier Plan View Live Load 40 lbs. / Sq Ft Dead Load 5 lbs. / Sq Ft VARIES: SGL Bolts, Nut, Washers 5/8" H.D. —�� - - - - •, . Galy Or S.S. (304) w n i _ ---------- Nu - - - - i�%� t. Fully Threaded -----; - - - ' . VARIES 2" x 6" SYP, .40 ACQ Decking #1 Grade w fi %'plank spacing . Fastener . • • w #10 3" SS (304) `o Screws, 2 per Stringer � m 2" x 8" P. T. SYP, .40 k 4 4 V% ACQ treated stringers to . _.._.._.._.._.._.. _.._MH_bV_. bebuttjointed, butt n N' Hill joints to be. staggered.. 2" x 8" P. T. SYP, .40 Si. Lls:, f r'Z7, ACQ treated DBL bents Dcie Irttl''t((_ �' l G DE X0. N li Stringers 24" ri .C. Max.. CCA �treated oil ! Center Stringer(s) toe Nailed w (2) #16 SS g (304), Ring Shank Nails @ Each Bent, - Outside Stringers Face Nailed w #16 SS (304) Ring - �, 'Shank Nails (See Nail Pattern Below) Pilings jetted to a minimum depth of 6' and as o M„� kn necessary.to provide. adequate bearing and stabili y W '� Q1 .j+2.. Z I .. .r a Zo y + • • • A x .Zo ice' 7 O i y. WAX Np Jerner&Associates, Inc. SHEET 3 --. Environmental Consulting Date: 614114 2280 SWEETWATER DRIVE FT PIERCE I 2537SEA1fonso Ave. Port St. Lucie, FL34952 Pk(772)283-2950 ,. E JERNER@BELLSOUTH.NET 04/17/2014 9:51 AM FAX 7722042180 SPANISH-LAKES-ONE 0001/0001 camarX ­862 _ f yu D iwi: M py ­1 .6b;."i ywikPI Custgrnor Job Number Qrder Code Data; Cualomor.Cvd% :.-...qLIstqrn . er-NAMB!�!-, I rs L • 1 =<3T M }w r .q .,%A n ujv t Ticket Dato: C. y f, Do'! P R M-11, Tickoi N-rtber. Y M Ay US R,E.-'���Y*�r..."Ib�,,L;,Pi..'O,I?e��i.L."Ow:,�"'A�4 ..6Y. V. �n, R1�11� ��,ylg Ilk, 5 a; M 0TIV river No..... End Use: -�K.Nurntlqr qr Number D Tr� Due b; TnNY.-. rNTONUCC-1- P. T"!Q E.,,' 4�580 k CUMULATIVE SCRIPTION 00M UNI'( PFUCF AMOV ROER90 rION LoAD - 0 MATM41� CODE PFtor)ix QUANTITY 1, QUANTITY: QUANTITY :A 3 �. - I , . vp,-­ .,, U �kf. I- q tit. qP V NMEN I -4 . .. ..... .. -.4 VV All R, 4 !7l.", Cash' ecelQedo- TotaT,QC?D qrderAmoPn0o Curb Ch.- eik IN Chock:; Comments: • GA� k-ADDED:_i� -YARQSINA)RU WATE.. TVVHF-N ADDED.: SIGNA:i APR" 17. CUR-Bi-LINE CROSSED AT OWNERVAGEN.TS RF(IIJPST: PE�Ml St. Lucle'' 0 LOAD WAS.TESTED;..;BY:' Notice: Our drivers, will make ovary effort to placu materials Where the customer designates, bOt thq SPECIALTERMS;I Any watar'sddaa f!;;at cdsiomoi;s own MY. ltwatoris atltledon job, conom", WARNING: Product muly cause sidn andfor o a iffitatlon. CAUTIQF�.!- Company a3uumqT..no roponsiblIlly for dampgos inside curt) o� property ling. Customer agrees to ilia Is no longoT.Quarantued, backside of this ficket r.- d6Q' 10 terms or wia and' delivery and accepts onlicrate as Is. Duc to Important factors which aro out of'.out. 'My. be OE6H? YOurlialft and -fffaase refut to the bed conlebi alter delivery; th!r, Co�npany)Nll� not accept any responsibility for the finIshod results. Nocredit f6r' safe' '**0.1 . mistlo . n, §Ad`�O h 't asloty, data sbasis for additional information. safety Om* ARat returned wnrrole. stsysra exceptions and cloirria shall be doamod waived unless mado to u!; in Writing' AUTHORIZED R I/V 'within ono business dq'after4ba rbcolpi of -materials, �t Florida Department 6-1 Environmental Protection Port St. Lucie Branch Office 1801 SE Hillmoor Drive, Suite C-204 Port St. Lucie, FL 34952 (772)398-2806 Fax #(772)398-2815 DEC 19 2007 ST. LL1C1F COUNl1' BUILDING DMSION William Wax REVIEWED FO 350 Lincoln Road, Suite S REVIEWED BY TTRt-2:7 Miami Beach, FL 33139 DATE — PL.Al\S Ari'D P;' IT MUST BE KEPT OIV JOB Re: File No.: 56-0284VYAM ViSPECTION WILL BE MADE. File Name: Wax, William Dear Mr. Wax: L/ ocG� 1, MIN. SETBACK REQ. I FRONT SIDES C N R SIDE REAR ZNG. - 2 TECH - Charlie Crist Governor Jeff Kottkamp Lt. Governor Michael W. Sole Secretary �� I I 1� NLI On November 30, 2007, we received your application for an exemption to perform the following activity: construct a 15' by 30' marginal dock with an associated single pole boatlift in the North Fork of the St. Lucie River, Class III Waters of the State, adjacent to 2260 Sweetwater Drive (Section 33, Township 35 South, Range 40 East), in Fort Pierce, St. Lucie County (Latitude 270 23' 31.74"N, Longitude 80° 20' 50.92" W). Your application has been reviewed to determine whether it qualifies for any of three kinds of authorization that may be necessary for work in wetlands or waters of the United States. The kinds of authorization are (1) regulatory authorization, (2) proprietary authorization (related to state-owned submerged lands), and (3) federal authorization. The authority for review and the outcomes of the reviews are listed below. Please read each section carefully. Your project may not have qualified for all three forms of authorization. If your project did not qualify for one or more of the authorizations, refer to the specific section dealing with that authorization for advice on how to obtain it. Regulatory Review. —EXEMPTION VERIFIED The Department has the authority to review your project under Part IV of Chapter 373, Florida Statutes (F.S.), Title 62, Florida Administrative Code (F.A.C.), and in accordance with operating agreements executed between the Department and the water management districts, as referenced in Chapter 62-113, F.A.C. Based on the information you submitted, we have determined that your project is exempt from the need to obtain a DEP Environmental Resource Permit under Rule 40E4.051(3)(b), F.A.G. Proprietary Review (related to state-owned lands). — GRANTED The Department acts as staff to the Board of Trustees of the Internal Improvement Trust Fund (Board of Trustees) and issues certain authorizations for the use of sovereign submerged lands. The Department has the authority to review your project under Chapters 253 and 258, F.S., Chapters 10-20 and 18-21, F.A.C., and Section 62-343.075, F.A.C. Your project will occur on sovereign submerged land and will require authorization from the Board of Trustees to use public property. As staff to the Board of Trustees, we have reviewed the proposed project and have determined that, as long as it is located within the described boundaries and is consistent with the attached general consent conditions, the project qualifies for a consent by rule to use sovereign submerged lands. Therefore, pursuant to Chapter 253.77, Florida Statutes, you may consider this letter as authorization from the Board of Trustees to perform the project. Federal Review (State Programmatic General Permit). — GRANTED Federal authorization for the proposed project is reviewed by DEP pursuant to an agreement between the Department and the U.S. Army Corps of Engineers (Corps). The agreement is outlined in a document titled More Protection, Less Process" inni, dcp.state. ll. m File Name: Wax, William FDEP File No.: 56-0284466-001 Page 2 Coordination Agreement Between the US. Army Corps of Engineers and the Florida Department of Environmental Protection State Programmatic General Permit, Section 10 of the Rivers and Harbor Act of 1899 and Section 404 of the Clean Water Act. Your project has been reviewed for compliance with a State Programmatic General Permit (SPGP). As shown on the attached drawings, the proposed project is consistent with the SPGP program. The attached Corps general conditions apply to your project. No further permitting for this activity is required by the Corps. The determinations in this letter are based solely on the information provided to the Department and on the statutes and rules in effect when the application was submitted. The determinations are effective only for the specific activity proposed. These determinations shall automatically expire if site conditions materially change or if the governing statutes or rules are amended. In addition, any substantial modifications in your plans should,be submitted to the Department for review, as changes may result in a permit being required. In any event, this determination shall expire after one year. This letter does not relieve you from the responsibility of obtaining other permits (federal, state, or local) that may be required for the project. NOTICE OF RIGHTS OF SUBSTANTIALLY AFFECTED PERSONS This letter acknowledges that the proposed activity is exempt from ERP permitting requirements under Rule 40E- 4.051(3)(b), F.A.C. This determination is final and effective on the date filed with the Clerk of the Department unless a sufficient petition for an administrative hearing is timely filed under sections 120.569 and 120.57 of the Florida Statutes as provided below. If a sufficient petition for an administrative hearing is timely filed, this determination automatically becomes only proposed agency action subject to the result ofthe administrative review process. Therefore, on the filing of a timely and sufficient petition, this action will not be final and effective until Anther order of the Department. The procedures for petitioning for a hearing are set forth in the attached notice. This determination is based on the information you provided the Department and the statutes and rules in effect when the application was submitted and is effective only for the specific activity proposed. This determination shall automatically expire if site conditions materially change or the governing statutes or rules are amended. In addition, any substantial modifications in your plans should be submitted to the Department for review, as changes may result in a permit being required. In any event, this determination shall expire after one year. Be advised that your neighbors and other parties who may be substantially affected by the proposed activity allowed under this determination of exemption have a right to request an administrative hearing on the Department's decision that the proposed activity qualifies for this exemption. Because the administrative hearing process is designed to redetermine final agency action on the application, the filing of a petition for an administrative hearing may result in a final determination that the proposed'activity is not authorized under the exemption established under Rule 40E4.051(3)(b), F.A.C. The Department will not publish notice of this determination. Publication of this notice by you is optional and is not required for you to proceed. However, in the event that an administrative hearing is held and the Department's determination is reversed, proceeding with the proposed activity before the time period for requesting an administrative hearing has expired would mean that the activity was conducted without the required permit. If you wish to limit the time within which all substantially affected persons may request an administrative hearing, you may elect to publish, at your own expense, the enclosed notice (Attachment A) in the Iegal advertisement section of a newspaper of general circulation in the county where the activity is to take place. A single publication will suffice. File Name: Wax, William FDEP File No.: 56-0284466-001 Page 3 If you wish to limit the time within which any specific persons) may request an administrative hearing, you may provide such person(s), by certified mail, a copy of this determination, including Attachment A. For the purposes of publication, a newspaper of general circulation means a newspaper meeting the requirements of sections 50.011 and 50.03I of the Florida Statutes. In the event you do publish this notice, within seven days of publication, you must provide to the following address proof of publication issued by the newspaper as provided in section 50.051 of the Florida Statutes. If you provide direct written notice to any person as noted above, you must provide to the following address a copy of the direct written notice. Florida Department of Environmental Protection Southeast District Branch Office 1801 SE Hilhnoor Drive, Suite C-204 Port St. Lucie F134952 If you have any questions, please contact Jerilyn Krug at"(772) 398-2806 x140 or at Jerilyn.Krug@dep.state.fl.us. When referring to your project, please use the FDEP file name and number listed above. Since , 12 �� 6r7 Eric M. Shea Date Environmental Supervisor Florida Department of Environmental Protection Southeast District Branch Office EMS/jak Enclosures: Federal Manatee Conditions, Federal General Conditions for SPGP IV and Transfer Request Attachment A- Notice of Determination of Qualification for Exemption General Conditions for Authorization cc: USACOE — Palm Beach Gardens, Eric.G.Reusch@saj02.usace.army.mil [without enclosures] Dana Rankin, Jerner and Associates, Inc., danarankin@belisouth.net [without enclosures] (Agent) IJA J. J RDIP- "OLD RON _� _ 7V., - 1 1, 4 CL_- L !-L L 4L 'L 4�:',LL N AL 7. tL J k DAD E RD SRO J tv eL k.. YVM DR MAR PL 1. LNqq nib !t DICKSONDR �'PRO 9 DR tL OftAW ur awwr- j A% 49. -_6 4,L4 A.4 q6 4L- > k4 pj -4- & AU J, jLl- 44 - - m-7 I, sL f 4- _PMERD MMAD 181SAVE ,4 Lk 5- Lou �---WWEAIHERBIFRD-� 4 tLA .-n P.M CD Af + �Lt- ellk m Z< o tmo 2MB m Edo zoom is-1 CD Z;Z� William M Wax Design &'Drowing by, DR C, -- shed I of 4 JeMer & Associates, Inc. Date: 2260 Sweetwater Drive Environmental Consulting F. 11/0 510 J7 Ft. Pierce, FL 34981 110 SWP Street, ft8rt FL 34994 Ph.(772)283-2950IFax (772)283-2760 O�n "CI PLAN VIEW PROPOSED Ten Mile; Creek Waterbody Width= 70'+/. 1 I I N 07, 1-0130,00 40, William Wax 2260 Sweetwater Drive Ft. Pierce, FL 34981 Proposed pile for side mount lift Proposed 15' X 30' Dock / I / 12341- 100 i i f I I � PLi i 157' +1- C.) �• w Design & Drawing by. DR Scale: 1" = 30' ro o c Jemer & Associates, Inc. 1' i77 Environmental Consulting Date: 11/07/07 a' i 1 110 SW. 61, street Stuart, FL 34994 Sheet 2 of d Ph.(7721283-29501Fax (772)283-2760 William Wax 2260 Sweetwater Drive Ft. Pierce, FL 34981 CROSS SECTION Proposed upland Stairs Proposed I5' X 30' Dock +—"-15) used Side ount Lift -------------- AWL Design & Drawing by. DR Scale: NTS Jemer & Associates, Inc. Environmental Consulting Date., 11/27/07 1 110 Sw. 5m Street Stuart, FL 34994 Sheet 3 of 4 Ph.(772)283-2950/Fax (772)283-2760 M M > > , c� Access Pilings jetted to a necessary to provide William Wax 2260 Sweetwater Ft. Pierce, FL 34 Terminal Thru 20X 6', ACQ, #1 Grada top I/- & 2'x4'mld handrags along access where no mooring occM depth of Wand as bearing and stability All Soft S H.D. Gala Or S.S. 2"x r SYR .60ACQ Decking#1 Grade wA- i4"plank spacing, 2" x 8" SYP, RS, .60 lCQ treated stringers, tap spliced 2"-x it SYP, RS, .60 ACQ treated bents -Min, 8" Dia. 2.5 - CCA heated piles *Access is 4' wide, Termini is 9' Design & Drawing by. OR - i demer & Associates, Inc. Environmental Consulting -..1 110 Sw. Sh street Stuart, FL 34994 Ph. (772)283-29501 Fax W2)283-2760 Access and Terminal Plan View "Varies e •_._•w•_._•_.i1. w•_.w•w,_•_._.,,,, it r5! i5! i i� i41 piles 10'to 12' O.C. Center Stdngsr(s) tole Nailed w SS 2(u:QMr Count Ring Shank Nair Outside <4' Wide Two Stringers Few Nailed 4'- 6' Wide Three v 8' Wide four o� 4 m o M �o O Z M Scale., 1 A = 4' Date: 11106107 Sheet 4 of 4 � 1 1 ENGINEERING SUBMITTALS MARCH 21, 2013 WIND LOAD CERTIFICATION: CODE: FBC 2010/FRC 2010/ASCE 7-10 WIND SPEED: 170 mph, 3 SEC. GUST EXPOSURE:"D" IMPORTANCE FACTOR: 1.0 INTERNAL PRESSURE COEFF.: 0.00 JOB: WILLIAM WAX 2260 SWEETWATER DRIVE FORT PIERCE, FLORIDA PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite #114 Port Saint Lucie, FL 34984 Phone E—Mail (772) 785-9888 pwelchinc®aol.com Paul Welch, P.E. Fla Reg No. 29945 y NIO INGBIRDWE" FLAMINGOA E 4a t I _"F r: q m MANOR DR . x EDWARDS RD N - OLD ED"WARDS RDA ! S&SY V m > k "`� KANNER QR° m ' a °� ,Ixr r il,.STONE ER •k`"' m = i 'z 7 _ WA DA VE o Eg ACE'-4= m:: m a o ', ID ay � Sy,�r _ � � .• L�•� c � I m al, r�lr . BHA ILOhI ER vzi. iQUTHLAND DR $ YIARK DR of RALS Rd r il` -0ADE RD �'` t I DIXIELAND DR fe x y RUSSEL `LNRA MAR PL ; n a m s = [a[j N£RR r z kARf E S MARKET RD DICK60N DRY ; ' y`i i .._;SELL AVE- x'',. o PRflSPE TY. DR, m { QEM BREL l 1 >`�� 11z7 z3.sae+' t� - ilr s 916a'� 20 94Y •i 4 ,r , -. ,;'° l 1t co St RKETAVE o 2, HCREEKL l !� I WOOD, LO L u L rn 'I` (V t S�NrtY QQ N - ,� 4, Z r omi Z �f - >Y' il PAIM' IAKES A4 k 't 4 1< m. y . $ > z (� W M(r} .: (`r f •. ...k 4't J WEGRETAVE� 1 ZJ1--3W f SERNITYCIRS' �p 4� m m >�LL� il il ;F ¢ �1 ¢` il< HERON AVE z 1' a .'Yn lJJ W g 1 .>ilr.Is AVE = .. ..:.. a W LoubEVINE RD 'DEWIE RD ;: .� ;2 $ �;.: t w r o o f il 1nIWEATHERBEER6 o. il z z J v, : _ dtP Gi�}�--- J W J H- e 0 f il 1• JJ RCIVAL ST t ..� ,: - .- :, � z a"e...i � •' rile J Data use subject to license. 0 1000 2000 0) 2004 DeLorme. Topo USA@ 5.0. 11 www.delorme.com MN (5.9' M Data Zoom 13-1 William Wax f__ _. _.___.j Design &Drawing by: DR Sheet 1 Jerner&Associates Inc. Date: 11/05/07 F—`- 1 r 2260 Sweetwater Drive f- i- -1 Lnvironmental Consulting Ft. Pierce FL 34981 —~ 1I0SW5u'Street Stuart FL34994 j Ph.(772)283-295WFax (772)283.2760 PLAN VIEW PROPOSED C. Ten Mile Creek I Waterbody Width= 70'+/- Proposed pile for side mount lift Proposed 15'X 30' Dock / / / / / 123'+/- 100, / PLi i F 157' +/- i Design & Drawing by DR William Wax r--;- —� Jerner & Associates, Inc. 2260 Sweetwater Drive -- - — Environmental Consulting Ff. Pierce, FL 34989 r-= -'—'-' 110SW.5'hStreet ��? Stuart FL 34994 Ph.(772)283-29501 Fax (772)283.2760 01AR 21 2013 Scale: 1 " = 30' Date: 11/07/07 PAUL WELCH 4NO. MECH-ELECT-CIVIL ENG 1984 BILTMORE ST. #114 Sheet 2 PORT ST. LUCIE, FL 34984 PAUL WELCH, P.E. FLA REG NO 29945 Access and Terminal Access and Terminal Section Thru Plan View 36 AL 6.0' Pilings jetted to a necessary to provide 2"X 6", ACQ, #1 Grade top & 2" x 4" mid handrails along access where no mooring occurs depth of 6' and as bearing and stability All Bolts 518" H.D. Galy. Or S.S. 2" x 6" SYP, . 60 Ai Decking #1 Grade %" plank spacing 2" x 8" SYP, RS, .6 ICQ treated stringe lap spliced 2" x 8" SYP, RS, .6 ACQ treated bentz _ Min. 8" Dia. 2.5 CCA treated piles William Wax (-- _ Design &Drawingby: DR 2260 Sweetwater D " f - I Jerner&Associates, Inc. rwe Environmental Consulting Ft. Pierce i-- - W.5t Street , FL 34981 { - - j-- 1I05 StuoM FL 34994 Ph.(772)283-29501 Fax(772)283-2760 *Varies Stringer Count <4' Wide Two 4' — 6' Wide Three 8' Wide Four __...�r Stringer(s) toe Nailed w SS Ring Shank Nails, Outside Stringers Face Nailed OAR 21 2013 Scale: 1" = 4' PAUL WELCH INC. Date: 11106107 MECH-ELECT-CIVIL ENG 1984 BILTMORE ST. #114 PORT ST. LUCIE, FL 34984 Sheet 3 PAUL WELCH, P.E. FLA REG NO 29945