APPLICATION FOR ROOF PERMIT
i n SEE REVERSE SIDS FOR INSTRUCTIONS � , A _
1. Location/Site Address:
2. ' 1 r • • 1 i ••• r
SCANNED
BY
Lucie Couny
Office Use
Only
Section
Townshi
Range
Map Page
Zoning
Land Use
Initials
3. Description of Projector Work Activity: �Awoe ' -'O� '00�/7� Izl'Alzo evt'8
4. Total Roof Area (square feet): �'�� 5. Roof Pitch: __31`0Z _
6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle
[ ] Tar & Gravel [ ] Modified Bitumen X1 Other �yf �j / �/C�//v►F
[pJ Product Approval required for all types of Roofing Material (2 Sets)
[p� All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner In -formation
- �
Name: , /%%jr/s , ,'O
Address: JZ& Z�-_2J/a j-"f
City: I�. Z'Zfj,`Ze' State:
8. Contractor Information
FL Reg/Cert #:
County Cert #:
Business Name:
Zip• Phone: -'%2- Cell Phone:
9. Value of Construction: $
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be
done in complian with all applicable laws regulating construction and zoning.
lmav kLA.F
PRINT QUALIFIERS/ nI RS NAME SIGNATURE OF QUALIFIER/O NER
STATE OF FLORIDA, COUNTY OF
ACKNOWLEDGED BEFORE ME THIS 1— DAY OF
NALLY OVI TO ME OR HAS.I;
ZA 0OF
—1
TAR TYPE C
COMMISSION NUMBER
BY I
Notary Public - State of Florida
;My Comm. Expires Mar 22, 2017
Commission # EE 877571
Bonded Through National Notary Assn.
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
PAUL WELCH INC.
Mechanical Electrical Civil Engineering
1984 S.W. Biltmore St. Suite# 114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Fax (772) 785-9933
March 5, 2014
Re: Huff Re -Roof
5192 Amy Ln.
Fort Pierce, FL 34946
SCOPE OF WORK:
Remove existing roofing at existing residence roof and install new 5-V Crimp Metal Roof (JA
Taylor Roofing Inc. FL # 14520.1) at above referenced residence address over new
underlayment and existing plywood sheathing.
This report does not include flat deck roofs at front and rear of residence.
DESIGN CRITERIA:
FBC 2010
ASCE7-10
PROJECT DATA:
BUILDING HIEGHT = 8' -0"
A= 3.0'
MEAN ROOF HIEGHT = <10'
ROOF ANGLE = 3:12
SHAPE = PITCHED GABLE
ADJUSTMENT FACTOR = 1.00
IMPROTANCE FACTOR = 1.00
WIND VELOCITY V ult = 160 MPH
WIND VELOCITY V asd = 124 MPH
0
EXPOSURE = C
ENCLOSURE CLASS = ENCLOSED BUILDING
INTERNAL PRESSURE COEFFICIENT = -0.18
APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (psfl:
ZONE 1 (Field) = -35.4
ZONE 2 (Perimeter/ Ridge) = -59.8
ZONE 3 (Corners) = -87.9
5192 Amy Ln. Fort Pierce, FL 34946 1 of 3
ATTACHIVIENT REQUIREMENTS:
Metal roofing to be attached with #9-15 corrosion resistant fasteners with sealing washers
designed for metal to wood connections of sufficient length to penetrate 5/16" through the
sheathing. Fasteners shall be installed along every crown of the rib in the center of the panel and
along the lap. Spacing as follows:
Zone 1 (Field): FASTENER SPACING = 16" O.C.
Zone 2 (Perimeter/ Ridge): FASTENER SPACING = 16" O.C.
Zone 3 (Corners): FASTENER SPACING = 8" O.C.
Panel Ends (Eaves): 6" O.C. ACROSS PANEL WIDTH.
Design uplift Pressure Zone 1 & Zone 2: -69.25 PSF 69.25 > 59.8 > 35.4 Therefore O.K.
Design uplift Pressure Zone 1 & Zone 2: -69.25 PSF 129.25 > 87.9 Therefore O.K.
DECK INSTALLATION:
Re -nail all plywood sheathing (15/32" thick minimum) with 8D ring -shank nails. Spacing as
follows:
Zone 1 & Zone 2: 6" O.C. perimeter and 6" O.C. field.
Zone 3: 4" O.C. perimeter and 4" O.C. field.
All work to be in compliance with product approval (FL # 14520.1), manufacturer's
specifications, and the Florida Building Code 2010.
Submitted by:
PAUL WELCH INC.
Paul elch, P.E.
Reg. No 29945
PW:PJ
5192 Amy Ln. Fort Pierce, FL 34946 2 of 3
.Ad
JA.M
ROOF ZONE PLAN
A=3'
ZONE DESIGNAHON (TYPICAL)
Paul Welch Inc.
Paul Welch P.E. Reg. No. 29945
March 5, 2014
5192 Amy Ln. Fort Pierce, FL 34946 3 of 3
.Florida Building Code Online
Page 1 of 2
Regulation
BCIS Homa : Log In User Registration � Hot Topics Submrt Surcharge Stats & Facts Publicatons FBC Staff BCIS Site Map Links Search
Busines
Professi jai Product Approval l
USER: PubluNic User
Regulation
Product Approval Menu > Product or Application Search > A;)pkaUon List > Application Detail
FL #
FL14520-R1
Application Type
Revision
Code Version
2010
Application Status
Approved
Comments
Archived
Product Manufacturer J A TAYLOR ROOFING
Address/Phone/Email 302 Melton Drive
FT PIERCE, FL 34982
(772) 466-4040
flvalidation@yahoo.com
Authorized Signature Kyle Taylor
flvalidation@yahoo.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Charles L THOMAS
the Evaluation Report
Florida License PE-29439
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/11/2021
Validated By Locke Bowden
;t Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
FL14520 R1 COI Certificate of Independence FPA.pdf
Standard
TAS 125
Method 1 Option D
11/07/2011
Year
2003
http://www.floridabuilding.org/Dr/pr ano dtl.asnx?paratn=wGEVXOwtDouxTVBiriRcYsC... 3/5/2014
Florida Building Code Online
Page 2 of 2
Date Validated 11/07/2011
Date Pending FBC Approval 11/10/2011
Date Approved 12/06/2011
Summary of Products
FL #
Model, Number or Name
Description
14520.1
5 V CRIMP
26GA METAL ROOFING PANEL
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14520 R1 II 5V Crimp Evaluation
Approved for use outside HVHZ: Yes
Report Details Rev.pdf
Impact Resistant: N/A
Verified By: PRI Construction Materials Technologies, LLC
Design Pressure: +N/A/-129.25
Created by Independent Third Party: Yes
Other: The required design wind loads shall be determined
Evaluation Reports
for each project per the Florida Building Code. The maximum
FL14520 R1 AE 5V Crimp Evaluation Report Rev.pdf
Created by Independent Third Party: Yes
fastener/clip spacing listed herein shall not be exceeded.
This product is not evaluated for use in the High Velocity
Hurricane Zone.
Back Next
Contact Us :: 1940 North Wnroe Street, Tallahassee FL. 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovnaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Satement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your email address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please dick hem .
ProductApprovalAcoepts:
lI
L�
Credit Card
SAFE
httn•//www flnridshrli1dinor nru/nr/nr nnn (it] nenY9naram=ixdTPITYnxxrtT)nttv'T TPiriRrVc(` 11/S/1)ntd
J.A. Taylor Roofing Inc.
Evaluation Report for
26 ga. 5V Crimp Metal Roof Assembly
FL# 14520-R1
Evaluation Report
Report for: J.A. Taylor Roofing Inc. Date: November 3, 2011
302 Melton Drive
Fort Pierce, FL 34982
Building Code:2010 Florida Building Code
Compliance Method:
Rule 9N-3.005(1)(d)
Section(s): 1504.3.2
Category:
Roofing
Project No.: FAE-001-01-01
Sub -Category:
Metal Roofing
Scope: Product Category: Roofing
Sub -Category. Metal Roofing
Compliance: The 26 ga. 5V Crimp Metal Roof Assembly described
herein has demonstrated compliance with Section
1504.3.2 of the 2010 Florida Building Code.
References: Test Application Standard (TAS) 125-03 Standard Requirements for Metal
Roofing Systems, Section 8 testing pursuant to Hurricane Test Laboratory, LLC
(FBC Organization ID No. TST1527) report no. 0224-0601-06, dated October 31,
2006.
Report addendum for report no. 0224-0501-06 (Specimen #1, 2, &4) issued by
Hurricane Test Laboratory, LLC (FBC Organization ID No. TST1527), dated
September 28, 2011
Drawings # '26" 5V 24" Coverage' issued by Hurricane Test Laboratory, LLC
(FBC Organization ID No. TST1527), dated September 20, 2011.
Engineering Analysis by PRI Construction Materials Technologies (FBC
Organization No.TST5878), dated April 19, 2011.
Product Description: 5V Crimp panel, minimum 26 ga. corrosion resistant steel (Grade 80), 26" panel
(24" maximum coverage), %" ribs; material shall comply with 2010 Florida
Building Code, Section 1507.4.3.
Minimum #9-15 HWH corrosion resistant fasteners with sealing washers
designed for metal to wood connections of sufficient length to penetrate 5/16"
through the sheathing. Material shall comply with 2010 Florida Building Code,
Section 1507.4.4.
Limitations: Limitations and Conditions of Use include the following.
• This evaluation does not include use of the product within the High -Velocity
Hurricane Zone (HVHZ).
• Fire Classification is not within scope of this Evaluation Report; refer to a
current Approved Roofing Materials Directory for fire ratings of this product.
Page 1 of 3
J.A. Taylor Roofing Inc.
Evaluation Report for
26 ga. 5V Crimp Metal Roof Assembly
FL# 14520-R1
• The product shall be installed in accordance with the Manufacturer's
instructions and the Roof Assemblies section herein.
• Modifications of the products as evaluated herein are beyond the scope of
this evaluation.
• All products listed herein shall have a quality assurance audit in accordance
with F.A.C. Rule 98-72.
Roof Assemblies: Assembly No. 1
Max Design Pressure: -69.25
Slope: 2:12 or greater
Deck: Minimum 15132" plywood or wood plank
Deck Attachment. In accordance with the applicable Code. In no case less
than minimum 8d x 2" annular ring shank nails spaced 6"
o.c. In reroofing, where the deck is less than 19/32" thick
(minimum 15/32") the above attachment method must be
in addition to existing attachment. Deck attachment to
be designed by others.
Underlayment. Minimum ASTM D 226, Type II (No. 30) in accordance
with Section 1507.2.8 of the 2010 Florida Building Code
or any Approved underlayment having current Florida
Statewide or Local Product Approval.
5V Crimp Panels: Installed in accordance with Manufacturer's installation
instructions. Minimum #9-15 corrosion resistant
fasteners with sealing washers designed for metal to
wood connections of sufficient length to penetrate 5/16"
through the sheathing installed 16" o.c. along the crown
of the rib in the center of panel and along the lap (See
Drawings).
Assembly No. 2
Max Design Pressure:-129.25
Slope: 2:12 or greater
Deck: Minimum 15/32" plywood or wood plank
Deck Attachment: In accordance with the applicable Code. In no case less
than minimum 8d x 2" annular ring shank nails spaced 6"
o.c. In reroofing, where the deck is less than 19/32" thick
(minimum 15/32") the above attachment method must be
in addition to existing attachment. Deck attachment to
be designed by others.
Underlayment: Minimum ASTM D 226, Type II (No. 30) in accordance
with Section 1507.2.8 of the 2010 Florida Building Code
or any Approved underlayment having current Florida
Page 2 of 3
J.A. Taylor Roofing Inc.
Evaluation Report for
26 ga. 5V Crimp Metal Roof Assembly
FL# 14520-R1
Statewide or Local Product Approval.
5V Crimp Panels: Installed in accordance with Manufacturer's installation
instructions. Minimum #9-15 corrosion resistant
fasteners with sealing washers designed for metal to
wood connections of sufficient length to penetrate 5/16"
through the sheathing installed 8" o.c. along the crown of
the rib in the center of panel and along the lap (See
Drawings).
Drawings:
5-V PANEL PROFILE
24" Coverage
5—V FASTENER DETA':i._
Quality Assurance: Keystone Certifications. (FBC Organization No. QUA1824)
Evaluator::G�!.'
Charles L. Thomas, P.E: L.
Florida Registered Profes'sru1 Enjpneer. ;
PE No.: 29439 l
FBC Organization No.: AMeW08 q
14609 Dixie Hwy, Hudson, FL 3/4697 vfc
Date. 1/ /3
Page 3 of 3