Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: RECEIPT #: Permit #: FEES DUE_ Planning & Development Services Department Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 St Tel. 772462-1553 APPLICATION FOR ROOF PERMIT i n SEE REVERSE SIDS FOR INSTRUCTIONS � , A _ 1. Location/Site Address: 2. ' 1 r • • 1 i ••• r SCANNED BY Lucie Couny Office Use Only Section Townshi Range Map Page Zoning Land Use Initials 3. Description of Projector Work Activity: �Awoe ' -'O� '00�/7� Izl'Alzo evt'8 4. Total Roof Area (square feet): �'�� 5. Roof Pitch: __31`0Z _ 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen X1 Other �yf �j / �/C�//v►F [pJ Product Approval required for all types of Roofing Material (2 Sets) [p� All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner In -formation - � Name: , /%%jr/s , ,'O Address: JZ& Z�-_2J/a j-"f City: I�. Z'Zfj,`Ze' State: 8. Contractor Information FL Reg/Cert #: County Cert #: Business Name: Zip• Phone: -'%2- Cell Phone: 9. Value of Construction: $ "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in complian with all applicable laws regulating construction and zoning. lmav kLA.F PRINT QUALIFIERS/ nI RS NAME SIGNATURE OF QUALIFIER/O NER STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS 1— DAY OF NALLY OVI TO ME OR HAS.I; ZA 0OF —1 TAR TYPE C COMMISSION NUMBER BY I Notary Public - State of Florida ;My Comm. Expires Mar 22, 2017 Commission # EE 877571 Bonded Through National Notary Assn. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite# 114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Fax (772) 785-9933 March 5, 2014 Re: Huff Re -Roof 5192 Amy Ln. Fort Pierce, FL 34946 SCOPE OF WORK: Remove existing roofing at existing residence roof and install new 5-V Crimp Metal Roof (JA Taylor Roofing Inc. FL # 14520.1) at above referenced residence address over new underlayment and existing plywood sheathing. This report does not include flat deck roofs at front and rear of residence. DESIGN CRITERIA: FBC 2010 ASCE7-10 PROJECT DATA: BUILDING HIEGHT = 8' -0" A= 3.0' MEAN ROOF HIEGHT = <10' ROOF ANGLE = 3:12 SHAPE = PITCHED GABLE ADJUSTMENT FACTOR = 1.00 IMPROTANCE FACTOR = 1.00 WIND VELOCITY V ult = 160 MPH WIND VELOCITY V asd = 124 MPH 0 EXPOSURE = C ENCLOSURE CLASS = ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = -0.18 APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (psfl: ZONE 1 (Field) = -35.4 ZONE 2 (Perimeter/ Ridge) = -59.8 ZONE 3 (Corners) = -87.9 5192 Amy Ln. Fort Pierce, FL 34946 1 of 3 ATTACHIVIENT REQUIREMENTS: Metal roofing to be attached with #9-15 corrosion resistant fasteners with sealing washers designed for metal to wood connections of sufficient length to penetrate 5/16" through the sheathing. Fasteners shall be installed along every crown of the rib in the center of the panel and along the lap. Spacing as follows: Zone 1 (Field): FASTENER SPACING = 16" O.C. Zone 2 (Perimeter/ Ridge): FASTENER SPACING = 16" O.C. Zone 3 (Corners): FASTENER SPACING = 8" O.C. Panel Ends (Eaves): 6" O.C. ACROSS PANEL WIDTH. Design uplift Pressure Zone 1 & Zone 2: -69.25 PSF 69.25 > 59.8 > 35.4 Therefore O.K. Design uplift Pressure Zone 1 & Zone 2: -69.25 PSF 129.25 > 87.9 Therefore O.K. DECK INSTALLATION: Re -nail all plywood sheathing (15/32" thick minimum) with 8D ring -shank nails. Spacing as follows: Zone 1 & Zone 2: 6" O.C. perimeter and 6" O.C. field. Zone 3: 4" O.C. perimeter and 4" O.C. field. All work to be in compliance with product approval (FL # 14520.1), manufacturer's specifications, and the Florida Building Code 2010. Submitted by: PAUL WELCH INC. Paul elch, P.E. Reg. No 29945 PW:PJ 5192 Amy Ln. Fort Pierce, FL 34946 2 of 3 .Ad JA.M ROOF ZONE PLAN A=3' ZONE DESIGNAHON (TYPICAL) Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 March 5, 2014 5192 Amy Ln. Fort Pierce, FL 34946 3 of 3 .Florida Building Code Online Page 1 of 2 Regulation BCIS Homa : Log In User Registration � Hot Topics Submrt Surcharge Stats & Facts Publicatons FBC Staff BCIS Site Map Links Search Busines Professi jai Product Approval l USER: PubluNic User Regulation Product Approval Menu > Product or Application Search > A;)pkaUon List > Application Detail FL # FL14520-R1 Application Type Revision Code Version 2010 Application Status Approved Comments Archived Product Manufacturer J A TAYLOR ROOFING Address/Phone/Email 302 Melton Drive FT PIERCE, FL 34982 (772) 466-4040 flvalidation@yahoo.com Authorized Signature Kyle Taylor flvalidation@yahoo.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Charles L THOMAS the Evaluation Report Florida License PE-29439 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/11/2021 Validated By Locke Bowden ;t Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted FL14520 R1 COI Certificate of Independence FPA.pdf Standard TAS 125 Method 1 Option D 11/07/2011 Year 2003 http://www.floridabuilding.org/Dr/pr ano dtl.asnx?paratn=wGEVXOwtDouxTVBiriRcYsC... 3/5/2014 Florida Building Code Online Page 2 of 2 Date Validated 11/07/2011 Date Pending FBC Approval 11/10/2011 Date Approved 12/06/2011 Summary of Products FL # Model, Number or Name Description 14520.1 5 V CRIMP 26GA METAL ROOFING PANEL Limits of Use Installation Instructions Approved for use in HVHZ: No FL14520 R1 II 5V Crimp Evaluation Approved for use outside HVHZ: Yes Report Details Rev.pdf Impact Resistant: N/A Verified By: PRI Construction Materials Technologies, LLC Design Pressure: +N/A/-129.25 Created by Independent Third Party: Yes Other: The required design wind loads shall be determined Evaluation Reports for each project per the Florida Building Code. The maximum FL14520 R1 AE 5V Crimp Evaluation Report Rev.pdf Created by Independent Third Party: Yes fastener/clip spacing listed herein shall not be exceeded. This product is not evaluated for use in the High Velocity Hurricane Zone. Back Next Contact Us :: 1940 North Wnroe Street, Tallahassee FL. 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coovnaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Satement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your email address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick hem . ProductApprovalAcoepts: lI L� Credit Card SAFE httn•//www flnridshrli1dinor nru/nr/nr nnn (it] nenY9naram=ixdTPITYnxxrtT)nttv'T TPiriRrVc(` 11/S/1)ntd J.A. Taylor Roofing Inc. Evaluation Report for 26 ga. 5V Crimp Metal Roof Assembly FL# 14520-R1 Evaluation Report Report for: J.A. Taylor Roofing Inc. Date: November 3, 2011 302 Melton Drive Fort Pierce, FL 34982 Building Code:2010 Florida Building Code Compliance Method: Rule 9N-3.005(1)(d) Section(s): 1504.3.2 Category: Roofing Project No.: FAE-001-01-01 Sub -Category: Metal Roofing Scope: Product Category: Roofing Sub -Category. Metal Roofing Compliance: The 26 ga. 5V Crimp Metal Roof Assembly described herein has demonstrated compliance with Section 1504.3.2 of the 2010 Florida Building Code. References: Test Application Standard (TAS) 125-03 Standard Requirements for Metal Roofing Systems, Section 8 testing pursuant to Hurricane Test Laboratory, LLC (FBC Organization ID No. TST1527) report no. 0224-0601-06, dated October 31, 2006. Report addendum for report no. 0224-0501-06 (Specimen #1, 2, &4) issued by Hurricane Test Laboratory, LLC (FBC Organization ID No. TST1527), dated September 28, 2011 Drawings # '26" 5V 24" Coverage' issued by Hurricane Test Laboratory, LLC (FBC Organization ID No. TST1527), dated September 20, 2011. Engineering Analysis by PRI Construction Materials Technologies (FBC Organization No.TST5878), dated April 19, 2011. Product Description: 5V Crimp panel, minimum 26 ga. corrosion resistant steel (Grade 80), 26" panel (24" maximum coverage), %" ribs; material shall comply with 2010 Florida Building Code, Section 1507.4.3. Minimum #9-15 HWH corrosion resistant fasteners with sealing washers designed for metal to wood connections of sufficient length to penetrate 5/16" through the sheathing. Material shall comply with 2010 Florida Building Code, Section 1507.4.4. Limitations: Limitations and Conditions of Use include the following. • This evaluation does not include use of the product within the High -Velocity Hurricane Zone (HVHZ). • Fire Classification is not within scope of this Evaluation Report; refer to a current Approved Roofing Materials Directory for fire ratings of this product. Page 1 of 3 J.A. Taylor Roofing Inc. Evaluation Report for 26 ga. 5V Crimp Metal Roof Assembly FL# 14520-R1 • The product shall be installed in accordance with the Manufacturer's instructions and the Roof Assemblies section herein. • Modifications of the products as evaluated herein are beyond the scope of this evaluation. • All products listed herein shall have a quality assurance audit in accordance with F.A.C. Rule 98-72. Roof Assemblies: Assembly No. 1 Max Design Pressure: -69.25 Slope: 2:12 or greater Deck: Minimum 15132" plywood or wood plank Deck Attachment. In accordance with the applicable Code. In no case less than minimum 8d x 2" annular ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (minimum 15/32") the above attachment method must be in addition to existing attachment. Deck attachment to be designed by others. Underlayment. Minimum ASTM D 226, Type II (No. 30) in accordance with Section 1507.2.8 of the 2010 Florida Building Code or any Approved underlayment having current Florida Statewide or Local Product Approval. 5V Crimp Panels: Installed in accordance with Manufacturer's installation instructions. Minimum #9-15 corrosion resistant fasteners with sealing washers designed for metal to wood connections of sufficient length to penetrate 5/16" through the sheathing installed 16" o.c. along the crown of the rib in the center of panel and along the lap (See Drawings). Assembly No. 2 Max Design Pressure:-129.25 Slope: 2:12 or greater Deck: Minimum 15/32" plywood or wood plank Deck Attachment: In accordance with the applicable Code. In no case less than minimum 8d x 2" annular ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (minimum 15/32") the above attachment method must be in addition to existing attachment. Deck attachment to be designed by others. Underlayment: Minimum ASTM D 226, Type II (No. 30) in accordance with Section 1507.2.8 of the 2010 Florida Building Code or any Approved underlayment having current Florida Page 2 of 3 J.A. Taylor Roofing Inc. Evaluation Report for 26 ga. 5V Crimp Metal Roof Assembly FL# 14520-R1 Statewide or Local Product Approval. 5V Crimp Panels: Installed in accordance with Manufacturer's installation instructions. Minimum #9-15 corrosion resistant fasteners with sealing washers designed for metal to wood connections of sufficient length to penetrate 5/16" through the sheathing installed 8" o.c. along the crown of the rib in the center of panel and along the lap (See Drawings). Drawings: 5-V PANEL PROFILE 24" Coverage 5—V FASTENER DETA':i._ Quality Assurance: Keystone Certifications. (FBC Organization No. QUA1824) Evaluator::G�!.' Charles L. Thomas, P.E: L. Florida Registered Profes'sru1 Enjpneer. ; PE No.: 29439 l FBC Organization No.: AMeW08 q 14609 Dixie Hwy, Hudson, FL 3/4697 vfc Date. 1/ /3 Page 3 of 3