HomeMy WebLinkAboutSUBMITTED PAPERSi DATE:. / i FEES Dut: '-- RECEIPT #: S Permit#.
Planning & Development Services Department
® Building.& Code Regulation Division SC
e 2300 Virginia Avenue 'y�%v��
Ft. Pierce, FL 34982-5652 Te1.772-062-1553 t' LU
APPLICATION FOR ROOF PERMIT c/� COUnfy
_ SEE REVERSE SDE FOR INSTRUCTIONS
1. Locatii n/Site Address: cye57��,
2. Parcel ® Number: Ow;,
Office Use
Only
Section
Township
Range
Map Page
Zoning
Land Use
Initials
;
3. Description of Project or Work Activity: 4 - <—'
4. Total oof Area (square feet): '�.1!"7 5. Roof Pitch: &)a—
S to [ ] Wood Shake / Shingle
6. Type o Roof: [ erglass Shing e [ ] oncrete Roof Tile
[ ] Tar & Gravel [ Ified Bitumen ( ] Other
roduct Approval required for all types of Roofing Material (2 Sets)
[ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
* * Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: )2d
City: ' -.C/1Q State: n
Zip: ei Phone:
9. Value of Construction: $ 03,%�J
FL Reg/Cert #: .1 -5�? f� `,
County Cert #:�)
Business Name:' `d<:-� S
Cell Phone: %_Pt-" l 3 !; -
**Note Dry�in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be
done in corn liance wiffiall applicable laws regulating construction and zoning.
PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY O
ACKNOWLEDGED BEFORE ME THIS DAY OF 2066 BY
NH PERSgNALLY KNOWN TO ME OR HAS PRODUCED - / AS IDENTIFICATION
S GNATURE O ARY E OR RINT NAME Q NOTARY (seal)
COMMISSIO NUMBER
NOTICE TO (OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY (BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26M
10
AUDREY B. HUMPHREY
MY COMMISSION 0 EE 061159
EXPIRES: March 6, 2015
Bonded Thru Notary Public Underwriters
Re: P lermit # M9;?- Q
M
Planning & Development Services
Building & Code Regulation. Division
2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-216S or 772-462-2172
'Fax: 772-462-6443
OF INSPECTION AFFIDAVIT
print name & circle license type)
licensed as a(n).Contractor*/Engineer/Architect
*FS468 Building Inspector
Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an Inspection.
On or about If 17cJI did personally inspect the roof deck nailing
( te) f
work at: (� �' ' /�-
(Job site address)
Based) upon that examination I have determined the installation was done according to the Hurricane
Retrofit Manual (Based on 553.844 F.S.)
Signature and Seal
i -�)2- 6 31
License #
STATE OF FLORIDA
COUNTY OF (L
Sw-Qq too and subscribed before me this / day of ti ' 20��
y ' �� - Who is personally known to me or who has produced
as identification. �� •��� 6
Lotary iPublic, State of Florida
Signatu,e of Notary:
Commission Number:. (Seal)
En
AUDREY B. HUMPHREY
?xr !A MY COMMISSION # EE 061159
w EXPIRES: Bonded hra Notary Public Underwriters nderwriters
W"
Mc.0L
(M > 0
0O;m`71m
q � 2 (0
z 1,3 c
G)c J0rn
..A� MCA
o-Dot7�
ov;0-.i
0G) am
M
oW X
Q4 O
�I M
�o n
n
C
0
0
G
X
-I
NOTICE OF COMMENCEMENT
TO BE COMPLETED WHEN CONSTRUCTION VALUE EXCEEDS $2,500.00
OR WHEN HEATING OR AIR CONDITIONING REPAIR OR REPLACEMENT EXCEEDS $7,500.00
I
PERMIT #: TAX FOLIO #: 1312-500-0088-000-6
State of Florida, County of St. Lucie, the undersigned hereby gives notice that improvement will be made to certain real
property, and in accordance with chapter 713, Florida statutes, the following information is provided in this notice of
Commencement.
1. LEGAL DESCRIPTION OF PROPERTY (AND STREET ADDRESS IF AVAILABLE):
HOLIDAY PINES S/D-PHASE I -LOT 87 (MAP 13/12S) (OR 322-1234)
2. I GENERAL DESCRIPTION OF IMPROVEMENT:
3.
❑ OWNER INFORMATION OR o LESSEE INFORMATION (If Lessee contracted for the improvement)
a. Name: Robert F and Frances H Bangert
Address: 5608 Eaale Drive. Fort Pierce. FL 34951
b. Interest in property:
c. Name and address of fee simple title holder (if other than owner):
4. CONTRACTOR:
a. Name: Lucas Roofing, Inc.
Address: 455 3` Lane SW, Vero Beach, FL 32962
b. Phone number: 772-567-0625
5. SURETY COMPANY (If Applicable, a copy of the payment bond is attached):
a. Name & Address:
b. Phone number: Bond amount:
6. LENDERIMORTGAGE COMPANY:
a. Name & Address:
b. Phone number:
7. PERSONS WITHIN THE STATE OF FLORIDA DESIGNATED BY OWNER UPON WHOM NOTICES OR OTHER
DOCUMENTS MAY BE SERVED AS PROVIDED BY SECTION 713.13 (1) (a) 7., FLORIDA STUTES:
a. Name & Address:
b. Phone number: Fax number:
8. IN ADDITION TO HIMSELF OR HERSELF,
a. Owner designates of to receive
a copy of the lienor's notice as provided in section 713.13(1) (b), Florida statutes.
b. Phone number:
9. j EXPIRATION DATE OF NOTICE OF COMMENCEMENT:
i(THE EXPIRATION DATE IS ONE (1) YEAR FROM THE DATE OF RECORDING UNLESS A DIFFERENT DATE IS SPECIFIED).
WARNING TO OWNER:
ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER
CHAdLLTER 713, PART I, SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE
OF C(7MMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
UNDER PENALTIES OF PERJURY, I DECLARE THAT I HAVE READ THE FOREGOING AND THAT THE FACTS IN IT ARE TRUE TO THE
BEST OF WLEDGE AND BELIEF (SECTIO , FLORIDA STATUTES)
X
[ � URE OF OW or LESSEE orOWN&WS AUTHORIZED OFFICER/DIRECTOR/PARTNER/MANAGER
SIGNATORY'S TILE/OFFICE
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS Y O h _ ' 20 I BY:
AS FOR
NAME OF PERSON TYPE OF AUTHORITY NAME OF PARTY ON BEHALF OF WHOM INSTRUMENT WAS EXECUTED
SRS0 A Y OWN ORPitUDUCED IDENTIFICATION TYPE OF IDENTIFICATION PRODUCED
NOTARY SIGNATURE NOTARY PRINTED NAME NOTARY.
EILEEN_LANKFOAD'
_:. . Noldry Public 4,tateof Floritfa
N" My Comm..Eicglres Ma9 12,;2015.
�d°� 'Commission-N Et.9363.1
vMW
��I,.
t+11�lt+Rl��
DEPARTMENT OF PERMITTING, ENVIRONiMENT, AND REGULATORY AFFAIRS (PERA)
BOARD AND CODE ADMINISTRATION DIVISION
i
NOTICE OF ACCEPTANC
CertainTeed Corporation
1400 Union Meeting Road
�, .,,
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33I75-2474
T (786) 315-2590 F (786) 315-2599
W ww. m i a mi d a de, eoV/pc ra
Blue Bell, PA 19422 Allk PM IV
rLJ
Y
SCOPE:
I L E '5 60"
This NTOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by. Miami -Dade County PERA - Product Control Section
to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/,or the AHJ (in areas other than Miami Dade County) reserve the right to .
.have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the
right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this
product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane'Zone of the Florida Building Code.
DESCRIPTION: Landmark, Landmark Plus, Landmark Premium, Landmark Special and Landmark
Solaris
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of -the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any
section of this NOA shall be cause for termination and removal. of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA# 09-0623.06 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
MIAMI-DADE C
OUNTYM NOA No.: 12-0201.05
• eAo
Expiration Date: 02/28/17
Approval Date: 03/08/12
Page l of 5.
IMOOFING ASSEMBLY APPROVAL
Category Roofilg
Sub -Category: Asphalt Shingles
Materials Dimes sional.
Lck Type: Wood
1.SCOPJr,
...(,
This renews Certa rx eed. LLan imark,, Landmark. Plus, Landmark Premium, Landmark Special
and Landmark Solans Shingles as manufactured by CertainTeed Corporation described in Section 2
of this Notice of Acceptance.
2. PRODUCT DESCRIPTION
Product
Dimensions
Test
Product Description
Snecifications
Certainteed Landmark
13'/4" x 38 3/4"
TAS 1.10
A heavy weight, 247lb/sq, dimensional
asphalt shingle.
Certainteed Landmark Plus
13?/4" x 38 3/4"
TAS 110
A. heavy weight, 264lb/sq, dimensional
asphalt shingle.
Certainteed Landmark
13'l4" x 38 3/"
TAS 110
A heavy weight, 2961b/sq, dimensional
Premium
asphalt shingle.
Certainteed Landmark Special
1394 x 38 3/4"
TAS 110
A heavy weight, 2641b/sq, dimensional
asphalt shingle.
Certainteed Landmark Solaris
13'�,4" x 38 3/4"
TAS 1.10
A heavy weight, 2961b/sq, dimensional
(
asphalt. shingle.
Accessory Shingles
various
proprietary
Accessory shingles for hip, ridge and
starter strip applications..
3. MANUFACTURING LOCATIONS}:
ndmjGA
EPeachtrejeCity,
Landmark Pins
Landmark
Premium
Landmark Special
Landmark Soiaris
Peachtree Cit GA
Peachtree City, GA
Peachtree City. GA
Peachtree City, GA
Ennis,. TX
ML4Mt•DL1DE COUNTY
'• r
NOA No.: 12-0201.05
Expiration Date: 02/28/17
Approval Date: 03/08/12
Page 1 of 5
4. EVIDENCE SUBMITTED:
Test A ency Test Identifier Test Name/Report
Underwriters Laboratories, Inc. _ Date
R684
PRI Asphalt Technologies, UL 796 04/02/01
Inc. PCTC-01-02-01
CTC-006-02-01 TAS 100 01/12,101
Underwriters Laboratories, Inc. 11/12/02
941vK9632 Wind uplift resistance TAS 107 11/30100
02NK42448
09CA28$73 11/08/02
Letter 07/23/ 9
5. LIMITATIONS
5.1 Fire classification is I not part of this acceptance; refer to a current Approved Roofine
Materials Directory for fire ratings of this product.
5.2 . Shall not be installed on roof mean heights in excess of 33 ft.
6. INSTALLATION
6.1 Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
6.2 Flashing shall be in accordance with Roofing Application Standard RAS 115
6.3 The manufacturer shall provide clearly written application instructions.
6.4 Exposure and course layout shall be in compliance with Detail W, attached.
6.5 Nailing shall be in compliance with Detail V, attached.
E
7. LABELING
7.1 Shingles shall be labeled with the Miami -Dade Product Control approved seal as seen below
or the wording "Miami -Dade County Product Control Approved".
8• BUILDING .PERMIT REQUIREMENTS
8.1 Application for building permit shall be accompanied by copies of the following:
8.1.1 This Notice of Acceptance.
8.1.2 Any other documents required by the Building Official or the applicable code in
order to properly.`evaluate the installation of this system.
E
MIAF1t•DADE COUNTY NOA No.: 12-0201.05
Expiration Date: 02/28/17
Approval Date: 03/08/12
Page 3 of 5
Sorts
MIAML•DADE C0UN NOA No.: 12-0201.05
° ° Expiration Date: 02/28/17
Approval Date: 03/08/12
Page 4 of 5
WIDE f
VA— NG®- l
AREA
MIAMII11 COUtdTY
...� a ��
LaIIUIIId[K rIUs,.LanamaR Premium, landmark Special and Landmark Solari
(Low, and Slandard Slope)
38 3/4"
Pius, landmark Premium, Landmark Special and Landmark Solaris
(Sleep Slope)
NOA No.: 12,-0201.05
Expiration Date: 02/28/17
Approval Date: 03/08/.12
Page 5 of 5
AVW
RINITYiERD
I
EVALUATION REPORT
Polyglass USA, Inc.
15.0 Lyon Drive
Fernley, NV 98408
SCOPE:
This Evaluation Report is
governing the use of const
has been reviewed by Robe
and Florida Building Code, I
to comply with the 2007 Flo
DESCRIPTION: POlyglaSS R
LABELING: Each unit shall be
Assurance Agency noted here
CONTINUED COMPLIANCE: Thi
changes, the referenced Qua
relate to the product change.
agreement to notify Robert.
Assurance documentation cr
Report relative to updated Co
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization ;#9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report P12060.02.09-115
FL5259-R10
Date of Issuance: 02/24/2009
Revision 5: 06/25/2010
sued under Rule 9B-72 and the applicable rules and regulations
:tion materials in the State of Florida. The documentation submitted
Nieminen, P.E. for use -of the product under the Florida Building Code
31dential Volume. The products described herein have been designed
a Building Code sections noted herein.
Underlayinents
r labeling in accordance with the requirements the Accredited Quality
Evaluation Report is valid until such time as the named product(s)
ty Assurance documentation changes, or provisions of the Code that
Acceptance of this Evaluation Report by the named client constitutes
Nieminen, P.E. if the product changes or the referenced Quality
inges. TrinityjERD requires a complete review of this Evaluation
e requirements with each Code Cycle.
ADVERTISEMENT: I tie. Evaluation Report number preceded by the words "Trinity IERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a !copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P.E. on 06/25/2010
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client'
CERTIFICATION OF INDEPENDENCE: .
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest In any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have; nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
,. _. M ,
l
RINITY ; ERD
ROOFING COMPONENT EVALUATION'.
1. SCOPE'
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have
demonstrated compliance with the following sections of the Florida Building Code (non-HVHZ) through
testing in accordance with the following Standards. Compliance is subject to the Installation
Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
1507.2.4, 1507.2.9.2, 1507
1507.5.3, 1507.6.3
1507.2.3, 1507.3.3, 1507.5
1507.7.3, 1507.8.3, 1507.9
1507.9.4
1507,11.2
1507.11.2
1504.6
1504.6
1504.3.1
3. REFERENCES:
Property
.3, Physical Properties
Entity
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 58.78)
PRI (TST 5878)
PRI (TST 5878)
MTI (TST 2508)
MTI (TST 2508)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ICC-ES (EVL 2396)
ICC-ES (EVL 2396)
Miami -Dade (CER 1.592)
Polyglass USA
Polyglass USA
UL (QUA1743)
Exterior Research and Design, LLC.
Certificate of Authorization 09503
Standard
ASTM D1970
Year
2001
Physical Properties ASTM D226 1997
Properties ASTM D6164 2000
Physical Properties
ASTM D6222
2002
Accelerated Aging
ASTM G154
2000
Accelerated Aging
ASTM G155
2004
Wind Uplift
FM 4470
1992
Examination
Reference
Date
Physical Properties
PRIO1111
04/08/2002
Physical Properties
PUSA-005-02-01
01/31/2002
Physical Properties
PUSA-013-02-01
12/23/2002
Physical Properties
PUSA-013-02-02
12/23/2002
Physical Properties
PUSA-013-02-03
12/23/2002
Physical Properties
PUSA-018-02-01
07/14/2003
Physical Properties
PUSA-028-02-01
07/13/2005
Physical Properties
PUSA-033-02-01
01/12/2006
Physical Properties
PUSA-035-02-01
09/29/2006
Physical Properties
PUSA-055-02-02
12/10/2007
Physical Properties
PUSA-061-02-02
01/28/2008
Physical Properties
PUSA-076-02-01
02/22/2008
Physical Properties
PUSA-063-02-01
04/14/2008
Physical Properties
PUSA-088-02-01
07/29/2009
Physical Properties
JX20H7A
04/01/2008
Physical Properties
RX14E8A
01/29/2009
Physical Properties
11752.09.99-1
02/08/2000
Physical Properties
02200.07.03
07/14/2003
Physical Properties
P5110.04.07-1
04/11/2007
Physical Properties
P13450.08.09
08/13/2009
Physical Properties
P33360.06.10
06/25/2010
IBC Compliance
ESR-1697
01/01/2005
IBC Compliance
ESR-1160
03/01/2005
HVHZ Compliance
NOA
Current
Manufacturing Affidavit
Products Current
02/18/2009
P/L Affidavit
Mule -Hide Cross Ltg
03/01/2008
Quality Control
File No. R14571, Vol 1
Exp, 11/30/2012
Evaluation Report P12060.02.09-R5
FL5259-R10
Revision 5: 06/25/2010
Page 2of9
z 416- . " >
fT�)INITYIERD
4. PRODUCT DESCRIPTION
4.1 Mechanically Fastened Underlayments:
4.1:1 ELAsrosASE is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 ELASTOBASE P is a polyester -reinforced, SBS modified bitumen base sheet.
4.2 Self -Adhering Qi+iderlayments:
4.2.1 POLYSTICK MTS is a rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface.
4.2.2 POLYSTICK IR-Xe iSi a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
sand surface.
4.2.3 POLYSTICK TU is al rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
granular surface.
4.2.4 POLYSTICK TU Plus °is a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
high strength polyester fabric surface.
4.2.5 POLYSTICK TU P is a rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced,
with a granular surface.
4.2.6 POLYFLEX SAP, POLYFLEX SAP FR, MULE -HIDE SA-APP CAP SHEET AND MULE -HIDE SA-APP CAP SHEET (FR)
are a polyester reinforced, APP modified bitumen cap sheets.
4.2.7 DUAL PROTM is a dual -layer rubberized asphalt waterproofing membranes, fiberglass reinforced,
with a high strength polyester fabric surface.
4.2.8 TILE PRO" is a dual -layer rubberized asphalt waterproofing membranes, fiberglass reinforced,
with a high. strength polyester fabric surface.
4.3 Mechanically Fa"stened and/or Bonded Underlayments:
4.3..1 ELASTOFLEX S6G AND ELASTOFLEX S6G FR are polyester reinforced, SBS modified bitumen cap
sheets.
4.3.2 POLYFLEx G AND POtYFLEx G FR are polyester reinforced, APP modified bitumen cap sheets.
5. LIMITATIONS:
5.1 This Evaluation_ Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the productis.
specifically referenced within FBC approval documents. If not listed, a request may be made
to the AHJ for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.4 Allowable roof Covers applied atop the underlayments are as follows:
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report P12060.02.09-I15
FL5259-RiO
Revision 5: 06/25/2010
Page 3 of 9
Table 1: Roof Cover Options
Underlayment
Asphalt
; Shingles
1 I
{fail -On Tile
Foam -On
Tile
Metal
Wood
Shakes &
Shingles
Slate
Elastobase
Yes
Yes
No
Yes
Yes
Yes
Elastobase P
Yes
Yes
No
Yes
Yes
Yes
Polystick MTS
Yes
(gattensonly)
No
Yes
Yes
Yes
j Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick TU
Yes
Yes
Yes
No
Yes
Yes
Polystick TU P
Yes
Yes
Yes
No
Yes
Yes
Polystick TU Plus
Yes
Yes
Yes
Yes
Yes
Yes
Dual Pro
Yes
Yes
No
Yes
Yes
Yes
Tile Pro
Yes
Yes
No
Yes
Yes
Yes
Elastoflex S6G or S6G FR
__.._.._.__._..._..---..__..__........_._...._..._._--
Yes
Yes
Yes
No
Yes
Yes
... .........
Polyflex G or G FR
Yes
Yes
Yes
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
or SA-APP Cap Sheet (FR)
Yes
Yes
Yes
No
Yes
Yes
5.4.1 "Foam -On Tile is limited to use of the following Approved tile adhesives unless tensile
adhesion / long term aging data from an accredited testing laboratory is provided.
Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Elastoflex S6G,
Elastoflex SSG FR, Polyflex G, Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide
SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR).
Dow TileBond: Polystick TU P or Polyflex SAP
5.4.1.1 The maximum design pressure for direct -bond Polystick self -adhering applications to plywood
or primed plywood is -135 psf. This is pertinent for foam -on tile systems only, where the
bonded underlayment forms part of the load -path.
5.4.2 For nail -on the systems over Polystick MTS, battens are required for both loading / staging of
the tile and tile`'. installation; direct-to-deck'naii-on tile applications are not permissible with
Polystick MTS. '
5.4.3 For mechanically attached metal and nail -on tile, an underlayment system consisting of
Polystick MTS followed by Polystick MTS, TU, TU P or TU Plus or Polystick SAP is permissible.
5.5 Allowable substrates are noted below:
5.5.1 Direct -Bond to Deck:
➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
self -adhered to: ASTM D41 primed structural concrete; OSB; Southern Yellow Pine; New
untreated plywood; existing plywood primed as needed with ASTM D41 primer; or Huber
Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for
project).
➢ Dual Pro or Tile Pro self -adhered to: New untreated plywood; or existing plywood primed
as needed with ASTM D41 primer.
➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D41 primed structural concrete.
➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete.
Exterior Research and Design; LLC. Evaluation Report P12060.02.09-R5
Certificate of Authorization #9503 FL5259-R10
Revision 5: 06/25/2010
Page 4 of 9
Q�f �11NJTY
I ERD
5.5.1.1 The maximum design pressure for direct -bond Polystick self -adhering applications to plywood
or primed plywood is -135 psf. This is pertinent for foam -on tilesystems only, where the
bonded underlayment forms part of the load -path. For other substrates, consult Polyglass
USA, Inc.
5.5.2 Bond-to-Insu
Y Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
self -adhered to: ASTM C1289, Type II, Class 1 polyisocyanurate or Type V
polyisocyanu rate -composite insulation; DensDeck DuraGuard; DensDeck Prime-, or
SECUROCK Gypsum -Fiber Roof Board.
➢ Elastoflex SdG or S6G FR in hot asphalt to: DensDeck Prime or SECUROCK Gypsum -Fiber
Roof Board.
➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck
Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation; under mechanically attached prepared roof coverings, insulation shall be
attached per minimum requirements of the prepared roof covering manufacturer's Product
Approval. For ;installations under foam -on tile systems, insulation shall be designed by a
qualified design': professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4470, Appendix K or TAS 114, Appendix J.
5.5.3 Bond to Mechanically Attached Base Layer:
➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase
P or Mule -Hide Nail Base.
Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase;
Elastobase P or Mule -Hide Nail Base.
➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base.
For installations; under mechanically attached prepared roof coverings, base layer shall be
attached per minimum codified requirements. For installations under foam -on the systems,
base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120.
5.6 Exposure Limitations:
5.6.1 Elastobase, Elastobase P, Dual Pro or Tile Pro shall not .be left exposed for longer than 30-
days. after installation.
5.6.2 Polystick IR-Xe shall not be left exposed for longer than. 90-days after installation.
5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be Left exposed for longer than 180-days after
installation.
5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not
have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in
which case the maximum exposure is 30 days.
5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, .unless
the prepared roof covering is to be adhesive=set tile, in which case the maximum exposure is
180 days.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
E
F
E
Evaluation Report P12060.02.09-1115
FL5259-R10
Revision 5: 06/25/2010
Page 5 of 9
`,J TRINITY ERD
5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth
Edition, use is limited to the following:
Table 2: Tile System Options for Roof Underlayments per FRSA/TRI 07320/8-05
System
Underlay
Option
Section
Reference
Product (s)
1
3.02A
Modified Cap Sheet
Elastoflex S6G or 56G FR; Polyflex G or G FR
2
3.026
No. 30 / Modified Cap
Elastobase; Elastobase P / Elastoflex S6G or S6G FR or
Sheet
Polyflex G or G FR
System One:
Mechanically
3
3.02C
No. 30 / Modified Cap
Sheet
Elastobase; Elastobase P / Elastoflex S6G or S6G FR
Fastened Tile,
4
3.02D
No. 30
Elastobase; Elastobase P
Unsealed or Sealed
self -Adhered
Polystick MTS (batten only); TO; TU P; TU Plus; Polyflex
Underlayment
5
3.02E
Underlayment
SAP or SAP FR; Mule -Hide SA-APP Cap Sheet or SA-APP
System
Cap Sheet (FR); Dual Pro; Tile Pro
Elastobase; Elastobase. P; Mule -Hide Nail Base / Polystick
6
3.02E
No. 30 / Self -Adhered
MTS (batten only); TO; TU P; TU Plus; Polyflex SAP or
Underlayment
SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap
Sheet (FR); Dual Pro; Tile Pro
1 i
3.02A
Modified Cap Sheet
Elastoflex S6G or S6G FR; Polyflex G or G FR
2
3.028
No. 30 / Modified Cap
Elastobase; Elastobase P / Elastoflex SGG or S6G FR or
Sheet
Polyflex G or G FR
System Two:
Mechanically
3
3.02C
No. 30 / Modified Cap
Sheet
Elastobase; Elastobase P /Elastoflex S6G or S6G FR
Fastened Tile,
Sealed
Self -Adhered
Polystick TO; TU P; TU Plus; Polyflex SAP or SAP FR;
Underlayment
4
3.02D
Underlayment
Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR);
System
Dual Pro; Tile Pro
Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick
5
3.02E
No. 30 / Self -Adhered
TO; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA-
Underlayment
APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro; Tile
Pro
1
3.02A
Modified Cap Sheet
Elastoflex S6G or S6G FR; Polyflex G or G FR
System Four "A":
2
g 02B-
No. 30 i Modified Cap
Elastobase; Elastobase P / Elastoflex S6G or S6G FR or
Adhesive -Set Tile,
Sheet
Polyflex G or G FR.
Unsealed or Sealed
4
3.02D
Self -Adhered
Polystick TO; TO P; TU Plus; Polyflex SAP or SAP FR;
Underlayment
Underlayment
Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
System
No. 30 / Self -Adhered
Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick
5
3.02E
Underlayment
TO, TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA-
APP Cap Sheet or SA-APP Cap Sheet (FR)
1.
3.02A
No. 30 / Modified Cap
Elastobase; Elastobase P / Elastoflex S6G or S6G FR or
SysteFour "B";
m
Sheet
Polyflex G or G FR
Adhesive -Set Tile,
3
3.D2C
Self -Adhered
Polystick TO; TU P; TU Plus; Polyflex SAP or SAP FR;
Sealed
Underlayment
Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)
Underlayment
System
No. / Self -Adhered
Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick
4
3.02D
Underrll Underlayment
TO; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA-
APP Cap Sheet or SA-APP Cap Sheet (FR)
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published
installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the
substrate thoroughly to remove any dust and debris prior to application, and prime the
substrate (if applicable).
Exterior Research and Design,,LLC.
Certificate of Authorization #9503€
Evaluation Report P12060.02.09-RS
FL5259-R10
Revision 5: 06/25/2010
Page 6of9
PTRRINITYIERD
6.3 Elastobase. Elastobase P or Mule -Hide Nail Base: j
6.3.1 Shall be installed in compliance. with the requirements for ASTM D226, Type II underlayment
in FBC Sections'1507 for the type of prepared roof covering to be installed.
6.3.2 For use in non -tile applications:
6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA
recommendations for installing shingle underlayments and flashings
6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick,
Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or
Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch
applied. f
6.3.3 For use in tile applications, reference Is made to Polyglass published installation instructions in
conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2
herein.
6.4 POlvstick MTS. IR-Xe. TU. TU P or TU Plus. Polvflex SAP or SAP FR_ Mulp-MidP S®-
6.4.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC
Sections 1507 for the type of prepared roof covering to be installed.
6.4.2 For non -tile appi;ications:
6.4.2.1 All self -adhering` materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR
and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage
edge seam as per Pol.ygiass / Mule -Hide Back Nailing Guide. Nails shall be corrosion resistant,
11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal
cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed using the
above noted fasteners and spacing, in area marked `nail area, area para clavar" on the face of
membrane. The' head lap membrane is to cover the area being back -nailed
6.4.2.2 All seal lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to
ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to
the end of the glue pattern (the sheet will overlap the fabric).
View of Ovelap Seam of Dual Pro and Tile Pro
Exterior Research and Design,;LLC.
Certificate of Authorization #95031
Evaluation Report P12060.02.09-115
FL5259-R10
Revision 5: 06/25/2010
Page 7of9
QTRINIITYIERD
6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing
Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing
Cement, Mule -Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule -Hide 421
Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap.
6.4.2.4 Polystick TU Plu`:s, Dual Pro and Tile Pro may not be used in any exposed application such as
crickets, exposed valleys, or exposed roof to wall details
6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55
Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG506 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement,
Mule -Hide 251 ;Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit
Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a minimum 6
x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the
repair area. Patch laps, if needed, shall be installed in a water shedding manner,
6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates.
Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff
broom with approximately 40-lbs of load applied for the field membrane, Hand rollers are
acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not
accessible to a large roller or broom.
6.4.3 For tile applications (not allowed for Polystick IR-Xe):
6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as
a guideline.
6.4.3.2 For nail -on the systems over Polystick MTS, battens are required for both loading / staging of
the the and tile! installation; direct -to -deck nail -on the applications are not permissible with
Polystick MTS.
i
6.5 Elastoflex S6G for S6G FR:
6.5.1 Elastoflex S6G. or S6G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications, reference is madeFRSA/TRI 07320/8-
05 Installation Manual, Fourth Edition, and Table 2 herein.
6.5.2 Elastoflex S6G or. S6G FR shall be fully asphalt -applied to the substrates noted in Section 5.5.
Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete
mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge..
6.6 Polyflex G or GFFR:
6.6.1 Polyflex. G or G F.R shall be installed in compliance with current Polyglass published installation
requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein.
6.6.2 Polyflex G or G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side
laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps
minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and
inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
Exterior Research and Design,;LLC. Evaluation Report 1212060.02.09-115
Certificate of Authorization #9503 iFL5259-R10
Revision 5: 06/25/2010
Page 8 of 9
6.7
6.7.1
6.7.2
6.7.3
6.7.4
�Jw
TRINITYI%ERD
Tile Staging:
A maximum of 6 tiles per stack are allowed when loading tile directly onto the underlayments.
Refer to the Polyglass Tile Loading Guidelines.
Battens and/or Counter:battens, as required by the tile manufacturer and FRSA/TRI 07320/8-
05 must be used on all roof slopes of 7:12 or greater. For roof slopes in excess of 61/4:12,
precautions should be taken, such as the use of battens to prevent tile sliding during the
loading process.`
For nail -on the systems over Polystick MTS, battens are required for both loading / staging of
the the and tile; installation; direct -to -deck nail' on the applications are not permissible with
Polystick MTS. E
The minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is fo)ty-eight (48) hours.
7. LABELING:
Each unit shall bear a
Accredited Quality Ass
BUILDING PERMIT REAL
As required by the Build
installation of this produc
9. MANUFACTURING
10.
Contact the noted QA
requirements
QUALITY ASSURANCE EN
Underwriters Laboratories
(847) 664-3281
nent label with the manufacturer's name, logo, city, state and logo of the
Agency noted herein.
Official or Authority Having Jurisdiction in order to properly evaluate the
ncy for information on product locations covered for F.A.C. Rule 9B-72 QA
Exterior Research and Design„LLC.
Certificate of Authorization #9503
Evaluation Report P12060.02.09-115
FL5259-R10
Revision 5: 06/25/2010
Page 9 of 9
Jeffrey D. McGee, P.E.
Structural Engineer, FL PE #45944
1102 SE Sabina Lane
CI6.1
APR 0 4 2014
Phone: 772-971-6435
email engmcgee@gmail com
PortSt. Lucie, FL 34983 PERIVIMING
uOunty, FL
April 1, 2014 plv?'__; L_ l..v C—`C"'
City of Fort Pierce; Building Department
RE: Tear Off, Re -Roof, Flat Roof, Bangert Residence
Project Location: 5608 Eagle Drive.
Fort Pierce, FL 34951
Roofing System: Polyglass USA, Inc.
Polyglass SBS and APP Modified Bitumen Roof Systems
Florida Product Approval, FL1654-R12
System No. W25: Recover System Type E, Non -Insulated, Mechanically Attached
Base Sheet, Bonded Roof Cover.
FL Uplift Allowable: -52.5 psf, Extrapolation Allowed
Design Parameters: ASCE 7-10, Risk Category II, Wind Speed: Vult = 160 mph (3 sec.),
Vasd = 124 mph, Exp. Cat.: B, Directionality Factor Kd=0.85
Design Roof Height: 14 feet, Kh=0.70, Zone Width = 4.0 feet
P 1=-27.6 psf, P2=46.4 psf, P3=-69.8 psf
Base Layer shall be GAFGLAS #75 Base Sheet, Fastened with Dekfast #14 (or other listed fastener),
with Hex Plate or 3" round insulation plate, length shall be sized to penetrate
existing wood deck by 3/4" minimum:
SIDE ROWS
CENTER ROWS
Zone 1 (Interior)
12" c/c, in 4" Lap
12" c/c 2 rows Staggered
Zone 2 Edge
12" c/c, in 4" Lap
12" c/c 2 rows Staggered
Zone 3 (Corner)
9"_ c/c, in 4" Lap.
9" c/c 2 rows Staggered'
Enhanced Perimeter Zone Width = 4'-0",
Ply sheet Elastoflex SA V, and Cap Sheet Elastoflex SA P shall be in compliance with the referenced FL
Product Approval. System installed in accordance with above meets or exceeds the required uplift
pressures as calculated above.
Sincerely*
01
Jeffrey D. McGee, PE
FL PE'948944
SAFETY 9 QUALITY • SERVICE
Moan ilk
Jeffrey D. McGee, P.E.
RE-CEIVE'o , °
Structural Engineer, FL PE #45944
1102 SE Sabina Lane APR 0 4 2014 Phone: 772-971-6435
email: engmcgee@gmail.com
Port St. Lucie, FL 34983 PERMITTING
unty, FL
April 1, 2014
City of Fort Pierce; Building Department
RE: Tear Off, Re -Roof, Flat Roof, Bangert Residence
Project Location: 5608 Eagle Drive.
Fort Pierce, FL 34951
Roofing System: Polyglass USA, Inc.
Polyglass SBS and APP Modified Bitumen
Florida Product Approval, FL1654-R12
System No. W25: Recover System Type E,
Base Sheet, Bonded Roof Cover.
FL Uplift Allowable: -52.5 psf, Extrapolation Allowed
Roof Systems
Non -Insulated, Mechanically Attached
Design Parameters: ASCE 7-10, Risk Category II, Wind Speed: Vult = 160 mph (3 sec.),
Vasd = 124 mph, Exp. Cat.: B, Directionality Factor Kd=0.85
Design Roof Height: 14 feet, Kh=0.70, Zone Width = 4.0 feet
P1=-27.6 psf, P2=46.4 psf, P3=-69.8 psf
Base Layer shall be GAFGLAS #75 Base Sheet, Fastened with Dekfast #14 (or other listed fastener),
with Hex Plate or 3" round insulation plate, length shall be sized to penetrate
existing wood deck by 3/4" minimum:
SIDE ROWS
CENTER ROWS
Zone 1 (Interior)
12" c/c, in 4" Lap
12" c/c 2 rows Staggered
Zone 2 Edge
12" c/c, in 4" Lap
12" c/c 2 rows Staggered
Zone 3 (Corner)
9" c/c, in 4" Lap
9" c/c 2 rows Staggered
Enhanced Perimeter Zone Width = 4'-0 ,
Ply sheet Elastoflex SA V, and Cap Sheet Elastoflex SA P shall be in compliance with the referenced FL
Product Approval. System installed in accordance with above meets or exceeds the required uplift
pressures as calculated above.
Siifncerely:'
Jeffrey.D..McGee, PE
.FL PE'##45944 .
SAFETY 9 QUALITY • SERVICE