Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSi DATE:. / i FEES Dut: '-- RECEIPT #: S Permit#. Planning & Development Services Department ® Building.& Code Regulation Division SC e 2300 Virginia Avenue 'y�%v�� Ft. Pierce, FL 34982-5652 Te1.772-062-1553 t' LU APPLICATION FOR ROOF PERMIT c/� COUnfy _ SEE REVERSE SDE FOR INSTRUCTIONS 1. Locatii n/Site Address: cye57��, 2. Parcel ® Number: Ow;, Office Use Only Section Township Range Map Page Zoning Land Use Initials ; 3. Description of Project or Work Activity: 4 - <—' 4. Total oof Area (square feet): '�.1!"7 5. Roof Pitch: &)a— S to [ ] Wood Shake / Shingle 6. Type o Roof: [ erglass Shing e [ ] oncrete Roof Tile [ ] Tar & Gravel [ Ified Bitumen ( ] Other roduct Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached * * Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: )2d City: ' -.C/1Q State: n Zip: ei Phone: 9. Value of Construction: $ 03,%�J FL Reg/Cert #: .1 -5�? f� `, County Cert #:�) Business Name:' `d<:-� S Cell Phone: %_Pt-" l 3 !; - **Note Dry�in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in corn liance wiffiall applicable laws regulating construction and zoning. PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY O ACKNOWLEDGED BEFORE ME THIS DAY OF 2066 BY NH PERSgNALLY KNOWN TO ME OR HAS PRODUCED - / AS IDENTIFICATION S GNATURE O ARY E OR RINT NAME Q NOTARY (seal) COMMISSIO NUMBER NOTICE TO (OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY (BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26M 10 AUDREY B. HUMPHREY MY COMMISSION 0 EE 061159 EXPIRES: March 6, 2015 Bonded Thru Notary Public Underwriters Re: P lermit # M9;?- Q M Planning & Development Services Building & Code Regulation. Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-216S or 772-462-2172 'Fax: 772-462-6443 OF INSPECTION AFFIDAVIT print name & circle license type) licensed as a(n).Contractor*/Engineer/Architect *FS468 Building Inspector Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an Inspection. On or about If 17cJI did personally inspect the roof deck nailing ( te) f work at: (� �' ' /�- (Job site address) Based) upon that examination I have determined the installation was done according to the Hurricane Retrofit Manual (Based on 553.844 F.S.) Signature and Seal i -�)2- 6 31 License # STATE OF FLORIDA COUNTY OF (L Sw-Qq too and subscribed before me this / day of ti ' 20�� y ' �� - Who is personally known to me or who has produced as identification. �� •��� 6 Lotary iPublic, State of Florida Signatu,e of Notary: Commission Number:. (Seal) En AUDREY B. HUMPHREY ?xr !A MY COMMISSION # EE 061159 w EXPIRES: Bonded hra Notary Public Underwriters nderwriters W" Mc.0L (M > 0 0O;m`71m q � 2 (0 z 1,3 c G)c J0rn ..A� MCA o-Dot7� ov;0-.i 0G) am M oW X Q4 O �I M �o n n C 0 0 G X -I NOTICE OF COMMENCEMENT TO BE COMPLETED WHEN CONSTRUCTION VALUE EXCEEDS $2,500.00 OR WHEN HEATING OR AIR CONDITIONING REPAIR OR REPLACEMENT EXCEEDS $7,500.00 I PERMIT #: TAX FOLIO #: 1312-500-0088-000-6 State of Florida, County of St. Lucie, the undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with chapter 713, Florida statutes, the following information is provided in this notice of Commencement. 1. LEGAL DESCRIPTION OF PROPERTY (AND STREET ADDRESS IF AVAILABLE): HOLIDAY PINES S/D-PHASE I -LOT 87 (MAP 13/12S) (OR 322-1234) 2. I GENERAL DESCRIPTION OF IMPROVEMENT: 3. ❑ OWNER INFORMATION OR o LESSEE INFORMATION (If Lessee contracted for the improvement) a. Name: Robert F and Frances H Bangert Address: 5608 Eaale Drive. Fort Pierce. FL 34951 b. Interest in property: c. Name and address of fee simple title holder (if other than owner): 4. CONTRACTOR: a. Name: Lucas Roofing, Inc. Address: 455 3` Lane SW, Vero Beach, FL 32962 b. Phone number: 772-567-0625 5. SURETY COMPANY (If Applicable, a copy of the payment bond is attached): a. Name & Address: b. Phone number: Bond amount: 6. LENDERIMORTGAGE COMPANY: a. Name & Address: b. Phone number: 7. PERSONS WITHIN THE STATE OF FLORIDA DESIGNATED BY OWNER UPON WHOM NOTICES OR OTHER DOCUMENTS MAY BE SERVED AS PROVIDED BY SECTION 713.13 (1) (a) 7., FLORIDA STUTES: a. Name & Address: b. Phone number: Fax number: 8. IN ADDITION TO HIMSELF OR HERSELF, a. Owner designates of to receive a copy of the lienor's notice as provided in section 713.13(1) (b), Florida statutes. b. Phone number: 9. j EXPIRATION DATE OF NOTICE OF COMMENCEMENT: i(THE EXPIRATION DATE IS ONE (1) YEAR FROM THE DATE OF RECORDING UNLESS A DIFFERENT DATE IS SPECIFIED). WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAdLLTER 713, PART I, SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF C(7MMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. UNDER PENALTIES OF PERJURY, I DECLARE THAT I HAVE READ THE FOREGOING AND THAT THE FACTS IN IT ARE TRUE TO THE BEST OF WLEDGE AND BELIEF (SECTIO , FLORIDA STATUTES) X [ � URE OF OW or LESSEE orOWN&WS AUTHORIZED OFFICER/DIRECTOR/PARTNER/MANAGER SIGNATORY'S TILE/OFFICE THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS Y O h _ ' 20 I BY: AS FOR NAME OF PERSON TYPE OF AUTHORITY NAME OF PARTY ON BEHALF OF WHOM INSTRUMENT WAS EXECUTED SRS0 A Y OWN ORPitUDUCED IDENTIFICATION TYPE OF IDENTIFICATION PRODUCED NOTARY SIGNATURE NOTARY PRINTED NAME NOTARY. EILEEN_LANKFOAD' _:. . Noldry Public 4,tateof Floritfa N" My Comm..Eicglres Ma9 12,;2015. �d°� 'Commission-N Et.9363.1 vMW ��I,. t+11�lt+Rl�� DEPARTMENT OF PERMITTING, ENVIRONiMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION i NOTICE OF ACCEPTANC CertainTeed Corporation 1400 Union Meeting Road �, .,, MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33I75-2474 T (786) 315-2590 F (786) 315-2599 W ww. m i a mi d a de, eoV/pc ra Blue Bell, PA 19422 Allk PM IV rLJ Y SCOPE: I L E '5 60" This NTOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by. Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/,or the AHJ (in areas other than Miami Dade County) reserve the right to . .have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane'Zone of the Florida Building Code. DESCRIPTION: Landmark, Landmark Plus, Landmark Premium, Landmark Special and Landmark Solaris LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of -the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal. of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 09-0623.06 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. MIAMI-DADE C OUNTYM NOA No.: 12-0201.05 • eAo Expiration Date: 02/28/17 Approval Date: 03/08/12 Page l of 5. IMOOFING ASSEMBLY APPROVAL Category Roofilg Sub -Category: Asphalt Shingles Materials Dimes sional. Lck Type: Wood 1.SCOPJr, ...(, This renews Certa rx eed. LLan imark,, Landmark. Plus, Landmark Premium, Landmark Special and Landmark Solans Shingles as manufactured by CertainTeed Corporation described in Section 2 of this Notice of Acceptance. 2. PRODUCT DESCRIPTION Product Dimensions Test Product Description Snecifications Certainteed Landmark 13'/4" x 38 3/4" TAS 1.10 A heavy weight, 247lb/sq, dimensional asphalt shingle. Certainteed Landmark Plus 13?/4" x 38 3/4" TAS 110 A. heavy weight, 264lb/sq, dimensional asphalt shingle. Certainteed Landmark 13'l4" x 38 3/" TAS 110 A heavy weight, 2961b/sq, dimensional Premium asphalt shingle. Certainteed Landmark Special 1394 x 38 3/4" TAS 110 A heavy weight, 2641b/sq, dimensional asphalt shingle. Certainteed Landmark Solaris 13'�,4" x 38 3/4" TAS 1.10 A heavy weight, 2961b/sq, dimensional ( asphalt. shingle. Accessory Shingles various proprietary Accessory shingles for hip, ridge and starter strip applications.. 3. MANUFACTURING LOCATIONS}: ndmjGA EPeachtrejeCity, Landmark Pins Landmark Premium Landmark Special Landmark Soiaris Peachtree Cit GA Peachtree City, GA Peachtree City. GA Peachtree City, GA Ennis,. TX ML4Mt•DL1DE COUNTY '• r NOA No.: 12-0201.05 Expiration Date: 02/28/17 Approval Date: 03/08/12 Page 1 of 5 4. EVIDENCE SUBMITTED: Test A ency Test Identifier Test Name/Report Underwriters Laboratories, Inc. _ Date R684 PRI Asphalt Technologies, UL 796 04/02/01 Inc. PCTC-01-02-01 CTC-006-02-01 TAS 100 01/12,101 Underwriters Laboratories, Inc. 11/12/02 941vK9632 Wind uplift resistance TAS 107 11/30100 02NK42448 09CA28$73 11/08/02 Letter 07/23/ 9 5. LIMITATIONS 5.1 Fire classification is I not part of this acceptance; refer to a current Approved Roofine Materials Directory for fire ratings of this product. 5.2 . Shall not be installed on roof mean heights in excess of 33 ft. 6. INSTALLATION 6.1 Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 6.2 Flashing shall be in accordance with Roofing Application Standard RAS 115 6.3 The manufacturer shall provide clearly written application instructions. 6.4 Exposure and course layout shall be in compliance with Detail W, attached. 6.5 Nailing shall be in compliance with Detail V, attached. E 7. LABELING 7.1 Shingles shall be labeled with the Miami -Dade Product Control approved seal as seen below or the wording "Miami -Dade County Product Control Approved". 8• BUILDING .PERMIT REQUIREMENTS 8.1 Application for building permit shall be accompanied by copies of the following: 8.1.1 This Notice of Acceptance. 8.1.2 Any other documents required by the Building Official or the applicable code in order to properly.`evaluate the installation of this system. E MIAF1t•DADE COUNTY NOA No.: 12-0201.05 Expiration Date: 02/28/17 Approval Date: 03/08/12 Page 3 of 5 Sorts MIAML•DADE C0UN NOA No.: 12-0201.05 ° ° Expiration Date: 02/28/17 Approval Date: 03/08/12 Page 4 of 5 WIDE f VA— NG®- l AREA MIAMII11 COUtdTY ...� a �� LaIIUIIId[K rIUs,.LanamaR Premium, landmark Special and Landmark Solari (Low, and Slandard Slope) 38 3/4" Pius, landmark Premium, Landmark Special and Landmark Solaris (Sleep Slope) NOA No.: 12,-0201.05 Expiration Date: 02/28/17 Approval Date: 03/08/.12 Page 5 of 5 AVW RINITYiERD I EVALUATION REPORT Polyglass USA, Inc. 15.0 Lyon Drive Fernley, NV 98408 SCOPE: This Evaluation Report is governing the use of const has been reviewed by Robe and Florida Building Code, I to comply with the 2007 Flo DESCRIPTION: POlyglaSS R LABELING: Each unit shall be Assurance Agency noted here CONTINUED COMPLIANCE: Thi changes, the referenced Qua relate to the product change. agreement to notify Robert. Assurance documentation cr Report relative to updated Co EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization ;#9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report P12060.02.09-115 FL5259-R10 Date of Issuance: 02/24/2009 Revision 5: 06/25/2010 sued under Rule 9B-72 and the applicable rules and regulations :tion materials in the State of Florida. The documentation submitted Nieminen, P.E. for use -of the product under the Florida Building Code 31dential Volume. The products described herein have been designed a Building Code sections noted herein. Underlayinents r labeling in accordance with the requirements the Accredited Quality Evaluation Report is valid until such time as the named product(s) ty Assurance documentation changes, or provisions of the Code that Acceptance of this Evaluation Report by the named client constitutes Nieminen, P.E. if the product changes or the referenced Quality inges. TrinityjERD requires a complete review of this Evaluation e requirements with each Code Cycle. ADVERTISEMENT: I tie. Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a !copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 06/25/2010 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client' CERTIFICATION OF INDEPENDENCE: . 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest In any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have; nor will acquire, a financial interest in any other entity involved in the approval process of the product. ,. _. M , l RINITY ; ERD ROOFING COMPONENT EVALUATION'. 1. SCOPE' Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code (non-HVHZ) through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section 1507.2.4, 1507.2.9.2, 1507 1507.5.3, 1507.6.3 1507.2.3, 1507.3.3, 1507.5 1507.7.3, 1507.8.3, 1507.9 1507.9.4 1507,11.2 1507.11.2 1504.6 1504.6 1504.3.1 3. REFERENCES: Property .3, Physical Properties Entity PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 58.78) PRI (TST 5878) PRI (TST 5878) MTI (TST 2508) MTI (TST 2508) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ICC-ES (EVL 2396) ICC-ES (EVL 2396) Miami -Dade (CER 1.592) Polyglass USA Polyglass USA UL (QUA1743) Exterior Research and Design, LLC. Certificate of Authorization 09503 Standard ASTM D1970 Year 2001 Physical Properties ASTM D226 1997 Properties ASTM D6164 2000 Physical Properties ASTM D6222 2002 Accelerated Aging ASTM G154 2000 Accelerated Aging ASTM G155 2004 Wind Uplift FM 4470 1992 Examination Reference Date Physical Properties PRIO1111 04/08/2002 Physical Properties PUSA-005-02-01 01/31/2002 Physical Properties PUSA-013-02-01 12/23/2002 Physical Properties PUSA-013-02-02 12/23/2002 Physical Properties PUSA-013-02-03 12/23/2002 Physical Properties PUSA-018-02-01 07/14/2003 Physical Properties PUSA-028-02-01 07/13/2005 Physical Properties PUSA-033-02-01 01/12/2006 Physical Properties PUSA-035-02-01 09/29/2006 Physical Properties PUSA-055-02-02 12/10/2007 Physical Properties PUSA-061-02-02 01/28/2008 Physical Properties PUSA-076-02-01 02/22/2008 Physical Properties PUSA-063-02-01 04/14/2008 Physical Properties PUSA-088-02-01 07/29/2009 Physical Properties JX20H7A 04/01/2008 Physical Properties RX14E8A 01/29/2009 Physical Properties 11752.09.99-1 02/08/2000 Physical Properties 02200.07.03 07/14/2003 Physical Properties P5110.04.07-1 04/11/2007 Physical Properties P13450.08.09 08/13/2009 Physical Properties P33360.06.10 06/25/2010 IBC Compliance ESR-1697 01/01/2005 IBC Compliance ESR-1160 03/01/2005 HVHZ Compliance NOA Current Manufacturing Affidavit Products Current 02/18/2009 P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Quality Control File No. R14571, Vol 1 Exp, 11/30/2012 Evaluation Report P12060.02.09-R5 FL5259-R10 Revision 5: 06/25/2010 Page 2of9 z 416- . " > fT�)INITYIERD 4. PRODUCT DESCRIPTION 4.1 Mechanically Fastened Underlayments: 4.1:1 ELAsrosASE is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 ELASTOBASE P is a polyester -reinforced, SBS modified bitumen base sheet. 4.2 Self -Adhering Qi+iderlayments: 4.2.1 POLYSTICK MTS is a rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface. 4.2.2 POLYSTICK IR-Xe iSi a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a sand surface. 4.2.3 POLYSTICK TU is al rubberized asphalt waterproofing membrane, glass fiber reinforced, with a granular surface. 4.2.4 POLYSTICK TU Plus °is a rubberized asphalt waterproofing membrane, glass fiber reinforced, with a high strength polyester fabric surface. 4.2.5 POLYSTICK TU P is a rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface. 4.2.6 POLYFLEX SAP, POLYFLEX SAP FR, MULE -HIDE SA-APP CAP SHEET AND MULE -HIDE SA-APP CAP SHEET (FR) are a polyester reinforced, APP modified bitumen cap sheets. 4.2.7 DUAL PROTM is a dual -layer rubberized asphalt waterproofing membranes, fiberglass reinforced, with a high strength polyester fabric surface. 4.2.8 TILE PRO" is a dual -layer rubberized asphalt waterproofing membranes, fiberglass reinforced, with a high. strength polyester fabric surface. 4.3 Mechanically Fa"stened and/or Bonded Underlayments: 4.3..1 ELASTOFLEX S6G AND ELASTOFLEX S6G FR are polyester reinforced, SBS modified bitumen cap sheets. 4.3.2 POLYFLEx G AND POtYFLEx G FR are polyester reinforced, APP modified bitumen cap sheets. 5. LIMITATIONS: 5.1 This Evaluation_ Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the productis. specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof Covers applied atop the underlayments are as follows: Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report P12060.02.09-I15 FL5259-RiO Revision 5: 06/25/2010 Page 3 of 9 Table 1: Roof Cover Options Underlayment Asphalt ; Shingles 1 I {fail -On Tile Foam -On Tile Metal Wood Shakes & Shingles Slate Elastobase Yes Yes No Yes Yes Yes Elastobase P Yes Yes No Yes Yes Yes Polystick MTS Yes (gattensonly) No Yes Yes Yes j Polystick IR-Xe Yes No No No Yes Yes Polystick TU Yes Yes Yes No Yes Yes Polystick TU P Yes Yes Yes No Yes Yes Polystick TU Plus Yes Yes Yes Yes Yes Yes Dual Pro Yes Yes No Yes Yes Yes Tile Pro Yes Yes No Yes Yes Yes Elastoflex S6G or S6G FR __.._.._.__._..._..---..__..__........_._...._..._._-- Yes Yes Yes No Yes Yes ... ......... Polyflex G or G FR Yes Yes Yes No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes No Yes Yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Yes Yes Yes No Yes Yes 5.4.1 "Foam -On Tile is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. Polyfoam PolyPro AH160: Polystick TU, Polystick TU P, Polystick TU Plus, Elastoflex S6G, Elastoflex SSG FR, Polyflex G, Polyflex G FR, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR). Dow TileBond: Polystick TU P or Polyflex SAP 5.4.1.1 The maximum design pressure for direct -bond Polystick self -adhering applications to plywood or primed plywood is -135 psf. This is pertinent for foam -on tile systems only, where the bonded underlayment forms part of the load -path. 5.4.2 For nail -on the systems over Polystick MTS, battens are required for both loading / staging of the tile and tile`'. installation; direct-to-deck'naii-on tile applications are not permissible with Polystick MTS. ' 5.4.3 For mechanically attached metal and nail -on tile, an underlayment system consisting of Polystick MTS followed by Polystick MTS, TU, TU P or TU Plus or Polystick SAP is permissible. 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ASTM D41 primed structural concrete; OSB; Southern Yellow Pine; New untreated plywood; existing plywood primed as needed with ASTM D41 primer; or Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). ➢ Dual Pro or Tile Pro self -adhered to: New untreated plywood; or existing plywood primed as needed with ASTM D41 primer. ➢ Elastoflex S6G or S6G FR in hot asphalt to: ASTM D41 primed structural concrete. ➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete. Exterior Research and Design; LLC. Evaluation Report P12060.02.09-R5 Certificate of Authorization #9503 FL5259-R10 Revision 5: 06/25/2010 Page 4 of 9 Q�f �11NJTY I ERD 5.5.1.1 The maximum design pressure for direct -bond Polystick self -adhering applications to plywood or primed plywood is -135 psf. This is pertinent for foam -on tilesystems only, where the bonded underlayment forms part of the load -path. For other substrates, consult Polyglass USA, Inc. 5.5.2 Bond-to-Insu Y Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanu rate -composite insulation; DensDeck DuraGuard; DensDeck Prime-, or SECUROCK Gypsum -Fiber Roof Board. ➢ Elastoflex SdG or S6G FR in hot asphalt to: DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. ➢ Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete; DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation; under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For ;installations under foam -on tile systems, insulation shall be designed by a qualified design': professional and installed based on testing of the insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114, Appendix J. 5.5.3 Bond to Mechanically Attached Base Layer: ➢ Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex S6G or S6G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. ➢ Polyflex G or G FR torch -applied to: Elastobase; Elastobase P or Mule -Hide Nail Base. For installations; under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on the systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. 5.6 Exposure Limitations: 5.6.1 Elastobase, Elastobase P, Dual Pro or Tile Pro shall not .be left exposed for longer than 30- days. after installation. 5.6.2 Polystick IR-Xe shall not be left exposed for longer than. 90-days after installation. 5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be Left exposed for longer than 180-days after installation. 5.6.4 Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. 5.6.5 Elastoflex S6G or S6G FR or Polyflex G or G FR does not have an exposure limitation, .unless the prepared roof covering is to be adhesive=set tile, in which case the maximum exposure is 180 days. Exterior Research and Design, LLC. Certificate of Authorization #9503 E F E Evaluation Report P12060.02.09-1115 FL5259-R10 Revision 5: 06/25/2010 Page 5 of 9 `,J TRINITY ERD 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following: Table 2: Tile System Options for Roof Underlayments per FRSA/TRI 07320/8-05 System Underlay Option Section Reference Product (s) 1 3.02A Modified Cap Sheet Elastoflex S6G or 56G FR; Polyflex G or G FR 2 3.026 No. 30 / Modified Cap Elastobase; Elastobase P / Elastoflex S6G or S6G FR or Sheet Polyflex G or G FR System One: Mechanically 3 3.02C No. 30 / Modified Cap Sheet Elastobase; Elastobase P / Elastoflex S6G or S6G FR Fastened Tile, 4 3.02D No. 30 Elastobase; Elastobase P Unsealed or Sealed self -Adhered Polystick MTS (batten only); TO; TU P; TU Plus; Polyflex Underlayment 5 3.02E Underlayment SAP or SAP FR; Mule -Hide SA-APP Cap Sheet or SA-APP System Cap Sheet (FR); Dual Pro; Tile Pro Elastobase; Elastobase. P; Mule -Hide Nail Base / Polystick 6 3.02E No. 30 / Self -Adhered MTS (batten only); TO; TU P; TU Plus; Polyflex SAP or Underlayment SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); Dual Pro; Tile Pro 1 i 3.02A Modified Cap Sheet Elastoflex S6G or S6G FR; Polyflex G or G FR 2 3.028 No. 30 / Modified Cap Elastobase; Elastobase P / Elastoflex SGG or S6G FR or Sheet Polyflex G or G FR System Two: Mechanically 3 3.02C No. 30 / Modified Cap Sheet Elastobase; Elastobase P /Elastoflex S6G or S6G FR Fastened Tile, Sealed Self -Adhered Polystick TO; TU P; TU Plus; Polyflex SAP or SAP FR; Underlayment 4 3.02D Underlayment Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR); System Dual Pro; Tile Pro Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick 5 3.02E No. 30 / Self -Adhered TO; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA- Underlayment APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro; Tile Pro 1 3.02A Modified Cap Sheet Elastoflex S6G or S6G FR; Polyflex G or G FR System Four "A": 2 g 02B- No. 30 i Modified Cap Elastobase; Elastobase P / Elastoflex S6G or S6G FR or Adhesive -Set Tile, Sheet Polyflex G or G FR. Unsealed or Sealed 4 3.02D Self -Adhered Polystick TO; TO P; TU Plus; Polyflex SAP or SAP FR; Underlayment Underlayment Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) System No. 30 / Self -Adhered Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick 5 3.02E Underlayment TO, TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA- APP Cap Sheet or SA-APP Cap Sheet (FR) 1. 3.02A No. 30 / Modified Cap Elastobase; Elastobase P / Elastoflex S6G or S6G FR or SysteFour "B"; m Sheet Polyflex G or G FR Adhesive -Set Tile, 3 3.D2C Self -Adhered Polystick TO; TU P; TU Plus; Polyflex SAP or SAP FR; Sealed Underlayment Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Underlayment System No. / Self -Adhered Elastobase; Elastobase P; Mule -Hide Nail Base / Polystick 4 3.02D Underrll Underlayment TO; TU P; TU Plus; Polyflex SAP or SAP FR, Mule -Hide SA- APP Cap Sheet or SA-APP Cap Sheet (FR) 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). Exterior Research and Design,,LLC. Certificate of Authorization #9503€ Evaluation Report P12060.02.09-RS FL5259-R10 Revision 5: 06/25/2010 Page 6of9 PTRRINITYIERD 6.3 Elastobase. Elastobase P or Mule -Hide Nail Base: j 6.3.1 Shall be installed in compliance. with the requirements for ASTM D226, Type II underlayment in FBC Sections'1507 for the type of prepared roof covering to be installed. 6.3.2 For use in non -tile applications: 6.3.2.1 Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings 6.3.2.2 Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex S6G or S6G FR in hot asphalt or Polyflex G or G FR, torch applied. f 6.3.3 For use in tile applications, reference Is made to Polyglass published installation instructions in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.4 POlvstick MTS. IR-Xe. TU. TU P or TU Plus. Polvflex SAP or SAP FR_ Mulp-MidP S®- 6.4.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non -tile appi;ications: 6.4.2.1 All self -adhering` materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam as per Pol.ygiass / Mule -Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed using the above noted fasteners and spacing, in area marked `nail area, area para clavar" on the face of membrane. The' head lap membrane is to cover the area being back -nailed 6.4.2.2 All seal lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Ovelap Seam of Dual Pro and Tile Pro Exterior Research and Design,;LLC. Certificate of Authorization #95031 Evaluation Report P12060.02.09-115 FL5259-R10 Revision 5: 06/25/2010 Page 7of9 QTRINIITYIERD 6.4.2.3 All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. 6.4.2.4 Polystick TU Plu`:s, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details 6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG506 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 ;Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner, 6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane, Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 For tile applications (not allowed for Polystick IR-Xe): 6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4.3.2 For nail -on the systems over Polystick MTS, battens are required for both loading / staging of the the and tile! installation; direct -to -deck nail -on the applications are not permissible with Polystick MTS. i 6.5 Elastoflex S6G for S6G FR: 6.5.1 Elastoflex S6G. or S6G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is madeFRSA/TRI 07320/8- 05 Installation Manual, Fourth Edition, and Table 2 herein. 6.5.2 Elastoflex S6G or. S6G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge.. 6.6 Polyflex G or GFFR: 6.6.1 Polyflex. G or G F.R shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications, reference is made FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.6.2 Polyflex G or G FR shall be fully asphalt -applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, and off set end -laps minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. Exterior Research and Design,;LLC. Evaluation Report 1212060.02.09-115 Certificate of Authorization #9503 iFL5259-R10 Revision 5: 06/25/2010 Page 8 of 9 6.7 6.7.1 6.7.2 6.7.3 6.7.4 �Jw TRINITYI%ERD Tile Staging: A maximum of 6 tiles per stack are allowed when loading tile directly onto the underlayments. Refer to the Polyglass Tile Loading Guidelines. Battens and/or Counter:battens, as required by the tile manufacturer and FRSA/TRI 07320/8- 05 must be used on all roof slopes of 7:12 or greater. For roof slopes in excess of 61/4:12, precautions should be taken, such as the use of battens to prevent tile sliding during the loading process.` For nail -on the systems over Polystick MTS, battens are required for both loading / staging of the the and tile; installation; direct -to -deck nail' on the applications are not permissible with Polystick MTS. E The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is fo)ty-eight (48) hours. 7. LABELING: Each unit shall bear a Accredited Quality Ass BUILDING PERMIT REAL As required by the Build installation of this produc 9. MANUFACTURING 10. Contact the noted QA requirements QUALITY ASSURANCE EN Underwriters Laboratories (847) 664-3281 nent label with the manufacturer's name, logo, city, state and logo of the Agency noted herein. Official or Authority Having Jurisdiction in order to properly evaluate the ncy for information on product locations covered for F.A.C. Rule 9B-72 QA Exterior Research and Design„LLC. Certificate of Authorization #9503 Evaluation Report P12060.02.09-115 FL5259-R10 Revision 5: 06/25/2010 Page 9 of 9 Jeffrey D. McGee, P.E. Structural Engineer, FL PE #45944 1102 SE Sabina Lane CI6.1 APR 0 4 2014 Phone: 772-971-6435 email engmcgee@gmail com PortSt. Lucie, FL 34983 PERIVIMING uOunty, FL April 1, 2014 plv?'__; L_ l..v C—`C"' City of Fort Pierce; Building Department RE: Tear Off, Re -Roof, Flat Roof, Bangert Residence Project Location: 5608 Eagle Drive. Fort Pierce, FL 34951 Roofing System: Polyglass USA, Inc. Polyglass SBS and APP Modified Bitumen Roof Systems Florida Product Approval, FL1654-R12 System No. W25: Recover System Type E, Non -Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover. FL Uplift Allowable: -52.5 psf, Extrapolation Allowed Design Parameters: ASCE 7-10, Risk Category II, Wind Speed: Vult = 160 mph (3 sec.), Vasd = 124 mph, Exp. Cat.: B, Directionality Factor Kd=0.85 Design Roof Height: 14 feet, Kh=0.70, Zone Width = 4.0 feet P 1=-27.6 psf, P2=46.4 psf, P3=-69.8 psf Base Layer shall be GAFGLAS #75 Base Sheet, Fastened with Dekfast #14 (or other listed fastener), with Hex Plate or 3" round insulation plate, length shall be sized to penetrate existing wood deck by 3/4" minimum: SIDE ROWS CENTER ROWS Zone 1 (Interior) 12" c/c, in 4" Lap 12" c/c 2 rows Staggered Zone 2 Edge 12" c/c, in 4" Lap 12" c/c 2 rows Staggered Zone 3 (Corner) 9"_ c/c, in 4" Lap. 9" c/c 2 rows Staggered' Enhanced Perimeter Zone Width = 4'-0", Ply sheet Elastoflex SA V, and Cap Sheet Elastoflex SA P shall be in compliance with the referenced FL Product Approval. System installed in accordance with above meets or exceeds the required uplift pressures as calculated above. Sincerely* 01 Jeffrey D. McGee, PE FL PE'948944 SAFETY 9 QUALITY • SERVICE Moan ilk Jeffrey D. McGee, P.E. RE-CEIVE'o , ° Structural Engineer, FL PE #45944 1102 SE Sabina Lane APR 0 4 2014 Phone: 772-971-6435 email: engmcgee@gmail.com Port St. Lucie, FL 34983 PERMITTING unty, FL April 1, 2014 City of Fort Pierce; Building Department RE: Tear Off, Re -Roof, Flat Roof, Bangert Residence Project Location: 5608 Eagle Drive. Fort Pierce, FL 34951 Roofing System: Polyglass USA, Inc. Polyglass SBS and APP Modified Bitumen Florida Product Approval, FL1654-R12 System No. W25: Recover System Type E, Base Sheet, Bonded Roof Cover. FL Uplift Allowable: -52.5 psf, Extrapolation Allowed Roof Systems Non -Insulated, Mechanically Attached Design Parameters: ASCE 7-10, Risk Category II, Wind Speed: Vult = 160 mph (3 sec.), Vasd = 124 mph, Exp. Cat.: B, Directionality Factor Kd=0.85 Design Roof Height: 14 feet, Kh=0.70, Zone Width = 4.0 feet P1=-27.6 psf, P2=46.4 psf, P3=-69.8 psf Base Layer shall be GAFGLAS #75 Base Sheet, Fastened with Dekfast #14 (or other listed fastener), with Hex Plate or 3" round insulation plate, length shall be sized to penetrate existing wood deck by 3/4" minimum: SIDE ROWS CENTER ROWS Zone 1 (Interior) 12" c/c, in 4" Lap 12" c/c 2 rows Staggered Zone 2 Edge 12" c/c, in 4" Lap 12" c/c 2 rows Staggered Zone 3 (Corner) 9" c/c, in 4" Lap 9" c/c 2 rows Staggered Enhanced Perimeter Zone Width = 4'-0 , Ply sheet Elastoflex SA V, and Cap Sheet Elastoflex SA P shall be in compliance with the referenced FL Product Approval. System installed in accordance with above meets or exceeds the required uplift pressures as calculated above. Siifncerely:' Jeffrey.D..McGee, PE .FL PE'##45944 . SAFETY 9 QUALITY • SERVICE