HomeMy WebLinkAboutSUBMITTED PAPERSDATE: a,X 1J I J q I FEES DUE: j • . C) n RECEIPT #: Permit #: 1 i O'A..Q a 00
SA Planning & Development Services Department
COU
NTYBuilding & Code Regulation Division SCgN
2300 Virginia Avenue NEB
Ft. Pierce, FL 34982-5652 SY
APPLICATION FOR ROOF PERMIT St Lucrc CoUnfy
SEE REVERSE SIDE FOR INSTRUCTIONS
1. Location/Site Address: 109 a 5 Olean -Drive Tencern Sea r.h, FIE-
2. Parcel ID Number: N 511- 5 01- o rl ol- 000 - 5 Uv h d reel our- 8U I - "T 1 b
Office Use
Only
Section
Township
Range
Map Page
Zoning
Land Use
Initials
3. Description of Projector Work Activity: Te. cxr off and Re- ROOF moles
4. Total Roof Area (square feet): 4F 5l) Q S F 5. Roof Pitch:
6. Type of Roof: M Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle
[ ] Tar & Gravel [ ] Modified Bitumen [ ] Other
[>C] Product Approval required for all types of Roofing Material (2 Sets)
[ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: 4- 1n g r I'd Tom
Address: 101al S S Ocean -Dr►v e - 1`1 y
City: S ericen 'bea eH State: Fl-
Zip: 3 4 q b'1 Phone: A 2 q- a a 1 a,
9. Value of Construction: $ a, N 6 A. 00
FL Reg/Cert #: C G C 0 3 b 1 9 0
County Cert #: PS a 8 4
Business Name: J4 eoL o n "R o a fi na
Cell Phone: g n a• as 7- D l I b
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of t jhfo tion contained in this application is correct and that all work will be
done in compli ysijh app laws regulating construction and zoning.
_Danti_1 £ 1 i EaAv>1 < ,v .
PRINT QUALIFIERS/OWNERS NAME SIGN E QUALIFIER
STATE OF FLORIDA, COUNTY OF Qt1 I11 tit
ACKNOWLEDGED BEFORE METIHS l y�h DAY OF Ff 6ru&r u 20. 1L, BY 'banl %:_ l Rf_0_+0n
WHO IS PERSONALLY KNOWN ME OR HAS PRODUCED AS IDENTIFICATION
yP
+("V*" ..�Aa ra M�kahch �11C-NIAIA �IwnqP Wkuhrn ."�`P��VICTORIADIANNEMCKUHEN
ATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY (seal)
* * MY COMMISSION # EE 214666
COMMISSION NUMBER E�_* al 4 L b 8 EXPIRES; Jury 21, 2016
�r4�OF F`O�\Ot Bonded Thru Budget Na" Services
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
Property Appraiser - St.Lucie Cou-,,,T FL Page 1 of 1
PROPERTY RECORD CARD
Ernest R Joy Sr (TR) Record: 1 of 1
«Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print
Property Identification
--�`�,QCIE00 ,
Site Address: 10725 S OCEAN DR 174
ParcellD: 4511-501-0279-000-5
SectTown/Range: l l :37S Al E
Account #: 123434 y�
Map ID: 45/11G
Use Type: Mob Homes
Zoning: HIRD
City/Cnty: Saint Lucie County
Ownership and Mailing
Legal Description
Owner: Ernest R Joy Sr (TR) Ingrid Joy (TR) HOLIDAY OUT AT ST LUCIE BLK I LOT 16 AND EQUAL PRO-RATA
Address: 10725 S Ocean Dr # 174
INTEREST IN COMMON ELEMENTS (OR 1394-890 ; 1
Jensen Beach FL 34957
More...
Sales Information
Assessment 2013 Total Land and Building
Date Price Code Deed
Book/Page 2013 Final: 63400 Land Value: 40300 Acres: 0.04
4/7/2004 100 01 QC
1938 / 1636 Assessed: 63400 Building Value: 23100
5/4/2001 60000 00 WD
1394 / 0890 Ag.Credit: 0 Finished Area: 730 SgFt
2/1/1979 0 01 CV
0303 / 1400 Exempt: 63400
3/l/1976 7500 00 CV
0249 / 1798 Taxable: 0
Taxes: 377.38
f1�1I�71�[�lhl��7:7�4L•��N7.1
Exterior Features
View:
-
RoofCover:
-
RoofStruct: -
ExtType:
MHH - MHH
YearBlt:
1989
Frame: -
Grade:
PKMA - PKMA
EffYrBlt:
1989
PrimeWall: -
StoryHght:
0010 -1 Story
No.Units:
1
SecWall: -
Interior Features
BedRooms:
0
Electric:
-
PrmintWall: -
FullBath:
0
HeatType:
FHA - FrcdHotAir
AvgHt/FI:
1/26ath:
0
HeatFuel:
ELEC - Electric
Prm.Flors: -
%A/C:
100
%Heated:
100
%Sprinkled: 0
Special Features and Yard Items
Land Information
Type Y/S
Qty. Units Qual.
Cond. YrBlt.
No. Use Type
Type Measure Depth
1 0200-Mob Homes
BI -Site 1
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
http://www.paslc.org/paslc/prc.asp?prclid=451150102790005 2/6/2014
Florida Building Code Online
Page 1 of 3
COPY
r �, s e'Y r=•3�w� yss"�'2'� �s�r�� .�h�� r-.,r � ix ,��� wa<��t str �i *r s J�A �' -k�
-;'Cin „'P�kir;l t.fl[r BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts
Busines �?�
Professil OUSER: Product Approval
Public User
Regulation
n
==K��..' '
t� t"�YC1k9YY'�S+
Publications FBC Staff BCIS Site Map Links Search
ISMIRWIlafflOM Product Approval Menu > Product or Apollcatlon Search > Application List > Application Detail
FL #
FL7006-R4
Application Type
Revision
Code Version
2010
Application Status
Approved
*Approved by DCA. Approvals by DCA shall be reviewed and
ratified by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer IKO Industries, Ltd
Address/Phone/Email 40 Hansen Road South
Brampton, NON -US L6W 3H4
(708)496-2800 Ext200
rrnetzOOI@tampabay.rr.com
Authorized Signature Robert Metz
rmetzOO1@tampabay.rr.com
Technical Representative Bob Metz
Address/Phone/Email REMCO of Pinellas
456 Avila Circle NE
Saint Petersburg, FL 33703
(727)776-5261
rmetz001@tampabay.rr.com
Quality Assurance Representative Andy Lodge
Address/Phone/Email IKO Industries LTD
40 Hansen Road S.
Brampton, FL 33703
(727)525-0342
rmetz001@tampabay.rr.com
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Certification Mark or Listing
Certification Agency FM Approvals - CER
Validated By Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Referenced Standard and Year (of Standard) Standard Year
ASTM D3161 modified to 110 mph 2006
ASTM Q3462 2007
ASTM1E108 2007
Equivalence of Product Standards
Certified By
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgse7mYBd2b3K... 4/24/2012
Florida Building Code Online
Page 2 of 3
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option A
03/06/2012
04/17/2012
04/23/2012
Summary of Products
FL #
Model, Number or Name
Description
7006.1
Cambridge AR and CRC Biltmore
Laminated architectural fiberglass asphalt shingle
AR
manufactured at IKO's Kankakee, IL, Hawkesbury, Ont.,
Wilmington, DE and Toronto, Ont. plants
Limits of Use
Certification Agency Certificate
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
FL7006 R4 C CAC 797-07219-267 - FBC ASTM
certification letter - 3-1-2 12 df
FL7006 R4 C CAC Shingle letter ASTM Compliance -
4-1 -2 1 f
Other:
Quality Assurance Contract Expiration Date
12/31/2018
Installation Instructions
FL7006 R4 II 8TTEFS-2012-01 8 5 x 11 Application
Instructions 3-2012. df
Verified By: FM Approvals - CER
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
7006.2
Hip and Ridge 12 Cap fiberglass
shingles
This is a 12" x 12" fiberglass asphalt shingle used to
cover the hip and/or ridge of an asphalt shingle roof
system manufactured In Toronto, Ont. and Brampton,
Ontario
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL7006 R4 C CAC 797-07219-267 - FBC ASTM
certification letter - 3-1-2012 df
FL7006 R4 C CAC Shingle letter ASTM Compliance -
4-16-2012 df
Quality Assurance Contract Expiration Date
Design Pressure: N/A
Other:
12/31/2018
Installation Instructions
FL7006 R4 II Hit) and Ridge Cap Shingle Installation
n
Verified By: FM Approvals - CER
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
7006.3
Leading Edge Plus Asphalt Shingle
One piece fiberglass asphalt shingle used as a starter
Starter Strip
strip at the bottom of a roof system manufactured In
Brampton, Ontario plant
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL7006 R4 C CAC 797-07219-267 - FBC ASTM
certification letter - 3-1-2012 . df
FL7006 R4 C CAC Shingle letter ASTM Compliance -
4-16-2012 . df
Quality Assurance Contract Expiration Date
Design Pressure: N/A
Other:
12/31/2018
Installation Instructions
FL7006 R4 II Leading Edae Plus Installation
Instruc I n . f
Verifled By: FM Approvals - CER
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
7006.4
Marathon 25 AR, CRC Superglass
M25AR
3 tab fiberglass asphalt shingle manufactured at IKO's
Brampton, Ontario, Hawkesbury Ont., Toronto and
Kanakakee,IL plants
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL7006 R4 C CAC 797-07219-267 - FBC ASTM
certification letter - 3-1-2012 . df
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgse7mYBd2b3K... 4/24/2012
Florida Building Code Online Page 3 of 3
I -
Impact Resistant: N/A FL7006 R4 C CAC Shingle letter ASTM Comoliance -
Design Pressure: N/A 4-1 - 1 . f
Other: Quality Assurance Contract Expiration Date
12/31/2018
Installation Instructions
FL7006 R4 II Marathon 25 AR Installation
Instructions. df
Verified By: FM Approvals - CER
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
Back Next
Contact Us :: 1940 North Monroe Street. Tallahassee FL 32322 phone: 850-487-1824
The State of Florida is an AA/EEO employer. Soovrioht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not
send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions regarding DBPR's ADA web
accesslblilty, please contact our Web Master at webmasterOdbimstate.fl.us.
Product Approval Accepts:
® eLhxk
NO�Of1 securit au•:nucs
SECURED i
F—c-d by verlSign
hlttp://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgse7mYBd2b3K... 4/24/2012
NOVEMBER 2004 No. R-50
REV. — JUNE 2012
FLORIDA STATE APPROVALS
IKO has achieved additional Product Approval for its line of shingles, including accessory products
in the. State of Florida. See the chart below which summarizes the latest information, along with
some key installation data. The shingles listed meet all current Code requirements.
IKO SHINGLE
Exposure
Offset
Shg/sq
M-D # (expiration)
Cambridge AR *
5-7/8"
4 —10"
60
11.0517.09 (5/5/16)
Marathon 25 AR *
5-5/8"
Min. 4"
65
11.1121.02 (5/5/16)
Hip & Ridge 12 *
5-1/8"
-
-
11.1121.01(5/19/16)
Leading Edge Plus *
6-5/8"
-
11.0318.02 (5/12/16)
ArmourShake **
5"
Min. 4"
70
-
Crowne Slate **
10"
4 -1/2"
40
-
Grandeur **
5-7/8"
4-10"
60
-
Marathon Ultra AR **
5-5/8"
Min. 4"
60
Royal Estate * *
5-5/8"
Min. 4"
64
-
`Florida Approval FL7006-R4, ** Florida Approval FL15550-111, ASTM E 108 Class A, ASTM D 3161 Class F, and
ASTM D 7158 Class H
Visit www.iko.com for complete technical data, application instructions, and limited warranty information.
The subject shingles conform to the requirements of ASTM's D 3462 product standard for glass
fiber reinforced asphalt shingles, as well as ASTM's D 3161 test method for wind resistance,
modified to 110 mph. Miami -Dade approved product bears the Miami -Dade logo on the product
wrappers and shingle release film. Visit http://www.miamidade.gov/building/pc-search app.asp for
specific details.
For additional information on any of IKO's products or application requirements, visit us on
the web at www.iko.com, or contact us in Canada at 1-888-766-2468, or the United States at
1-888-456-7663.
rI No
• 1r�
Setting the Standard
MIAMIdD E
® MIAMI-DADS COUNTY
PRODUCT CONTROL SECTION
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33I75-2474
T (786) 315-2590 F (786) 315.2599
NOTICE OF ACCEPTANCE (NOA) www.mtamidade mylbuilding/
Iko Industries Ltd.
40 Hansen Rd. S.
Brampton, Ontario CANADA
L6W3I34
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the'expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Cambridge AR
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINAVON of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This revises NOA# 10-0913.02 and consists of pages l through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11-0517.09
Expiration Date: 05/05/16
Approval Date: 07/07/11
Page 1 of 4
ROOFING ASSEMBLY APPROVAL
Cate o :
Roofing
Sub -Category:
Asphalt Shingles
Materials
Laminate
Deck Type•
Wood
SCOPE
This approves a roofing system using Cambridge AR asphalt shingles manufactured by IKO Industries Ltd. as
described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test
Product Descrintion
Specifications
Cambridge AR 13 3/4" x 40 7/g" TAS 110
A heavy weight, fiberglass reinforced
laminate asphalt shingle.
MANUFACTURING LOCATION
1. Kankakee, IL
EVIDENCE SUBMITTED
Test Anencv Test Identifier
Test Name/Reaort Date
PRI Construction Materials Inc: IKO-050-02-01
TAS 100 12/21/09
FM Approvals 3041689
ASTM D 3462 02/23/11
FM Approvals 3036971
ASTM D 3161 -(TAS-107) 01/04/09
FM Approvals 3042673
ASTM E 108 04/12/11
LIMITATIONS
I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 913-72 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W, attached.
5. Nailing shall be in compliance with Detail'B', attached.
NOA No.:11-0517.09
Expiration Date: 05/05/16
Approval Date: 07/07/11
Page 2 of 4
LABELING
1. Shingles shall be labeled with the Miami -Dade Seal as Been below, or the wording "Miami -Dade County
Product Control Approved".
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
L APPROVED J
NOA No.: 11-0517.09
Expiration Date: 05/05/16
Approval Date: 07/07/11
Page 3 of 4
DETAIL A
CAMBRIDGE AR COURSE LAYOUT
DGEOF ROOF
---------------
Note: Rooting Cement not shown In this IayouL
This drawing Is for course layout only. See Deld B
rr------,- - for naliing and cement plaosment detells.
f't ---- THIRD COURSE
I
I I
SECOND COURSE
I I
FIRST COURSE
DETAIL B
CAMBRIDGE AR
END OF THIS ACCEPTANCE
5' EXPOSURE
-�f
NOA No.: 11-0517.09
Expiration Date: 05/05/16
Approval Date: 07/07/11
Page 4 of 4
<:FMApprovals�
FM Approvals Member of dw N clobai crcwp
1151 Boston -Providence Turnpike
P.O. Box 9102 Norwood, MA 02062 USA
T: 781762 4300 F: 781762 9375 www.finapprovals.com
April 16,2012
Mr. Andy Lodge
IKO Industries, Ltd.
40 Hansen Road South
Brampton, Ontario L6W 3H4
Canada
Subject: FM Approved Steep Slope Roofing Products listed in RoofNav
Dear Andy:
This letter is being written as a follow up to our telephone conversation of earlier today. Please be
advised that the following shingles have been tested and Approved in accordance with FM
Standard 4475 Approval Standard for Class 1 Steep Slope Roof Covers:
IKO Industries Ltd.: Cambridge, Cambridge AR, Crowne Slate, Hip & Ridge 12, Marathon 25
Al?, Marathon Ultra AR, Grandeur, and Leading Edge Plus
Canroof Corp.: Biltmore, Biltmore AR, CRC Hip & Ridge 12, Superglass 25 AR, and Superglass
Ultra AR
These shingles are listed in RoofNav the on-line resource of FM Approvals as of April 16, 2012.
RoofNav can be accessed at www.RoofNay.com
If you have any questions please do not hesitate to contact me.
Very truly yours,
�"/ /
David L. Alves Phillip J. Smith, P.E., Asst. Vice President
Senior Engineer - Materials Group Technical Team Manager
FM Approvals FM Approvals
T: 781 255 4856
F: 781 762 9375
E: david.alvesafmMprovals.com
O G. FM FM
a' C E APPROVED
APPROVED
t % I
FM Approvalse
FM Approvals Member of the FM Global Group
1151 Boston -Providence Turnpike
P.O. Box 9102 Norwood, MA 02062 USA
T: 781762 4300 F: 781762 9375 www.fmapprovals.com
March 1, 2012
Mr. Andy Lodge
IKO Industries, Ltd.
40 Hansen Road South
Brampton, Ontario L6W 3H4
Canada
Project ID: 3036971
Subject: Certification Letter for ASTM Testing of Various IKO Industries Ltd. and Canroof
Corporation, Inc. roof shingles
Customer ID: 100000686
Dear Mr. Lodge:
This letter is being written as a follow up to your request for documentation regarding testing performed
thus far for the shingles. The table below includes the shingle name, manufacturing locations, most recent
ASTM test procedures and the FM Approvals project Identification Number under which the tests were
performed:
Shingle name:
Leading Edge
Hip & Ridge 12
Cambridge AR
Marathon 25 AR
Plus
and
CRC Superglass
25 AR
Manufacturing
IKO - Brampton,
IKO - Brampton,
Canroof - Toronto,
IKO - Brampton,
Locations:
Canroof - Toronto
IKO — Kankakee,
Camoof - Toronto,
IKO — Wilmington
IKO - Hawkesbury
IKO-Hawkesbury,
ASTM D 3161-06:
Project: 3040947
Project: 3040947
Project: 3040947
Project: 3040947
ASTM D 3462-07:
Project: 3041689
Project: 3041689
Project: 3041689
Project: 3041689
for Toronto,
for Toronto,
Kankakee and
Kankakee and
Wilmington
Wilmington
Project:3045254
Project:3045254
for Hawkesbury
for Hawkesbury
ASTM E 108-07:
1 Project: 3010968
1 Project: 3010968
Project: 3010968
Project: 3010968
FM US �X
APPROVED
s
r T
_< FMApprouals-
Member of the FM Global Group
If you have any questions please do not hesitate to contact me.
Very truly yours,
David L. Alves
Senior Engineer - Materials Group
FM Approvals
T: 781 255 4856
F: 781 762 9375
E: david.alves(@finanorovals.com
Phillip J. Smith, P.E., Asst. Vice President
Technical Team Manager
FM Approvals