Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
DATE: /, Ik' -/ J/, I FEES DUE: IN —1 1 RECEIPT #: ` I Permit #: f, %: _ 1 / I r- Planning & Development Services Department ® Building & Code Regulation Division �� o s 2300 Virginia Avenue )// , Ft. Pierce, FL 34982-5652 Tel. 772-462-1553 �!' Cie C APPLICATION FOR ROOF PERMIT °Uri SEE REVERSE SIDE FOR INSTRUCTIONS 1. Location/Site Address: 4703 Eagle br. Fowt Piev-ce- FL 3495i - 23(.9 ci 2. Parcel ID Number: 1312 - 430 i - 00 4o - 000 - 2- Ofrice Use Only Section Township Range Map Page Zoning Land Use Initials 9 3. Description of Project or Work Activity: Re - rO aF ftea-r ovip 22 4. Total Roof Area (square feet): 3.5 -7 L 5. Roof Pitch: 5 I 6. Type of Roof: A Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other [)(] Product.Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: Gerald e$'"Ali o Address: 3703 Eaq Le; 'Dr. CJ City: FrL?,"c.e State: FL Zip: 3g951 Phone: 772 359 -7437 9. Value of Construction: $ 10 c 000 - o0 "Note Dry -in and Final Inspection Required. Additional CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all FL Reg/Cert #: C Q C 13 3 0 0 0 S County Cert #: Z7 4 / Business Name: Sor©ka Rccs!',,r .I_1_C Cell Phone:( 77 ) 559 - S R 4 y may )ie required per Product Approval. contained in this application is correct and that all work will be able laws regulating construction and zoning. Damn-1 c7oc014a IT!a PRINT QUALIFIERS/OWNERS NAME t SIGNAaVRE OF UA IFIER/OWNER STATE OF FLORIDA, COUNTY O - s ACKNOWLEDGED BEFORE ME THIS DAY OF 20 �� S PERSONALLY WN TO ME OR HAS UCED .,•��Pny PLs�•,, DAWN MILONE - ,,� * • My Comm. Expires Mar 22, 2017 SIGIZXTURE OF NOTARY TYPE OR PRINT NAME OF NOT 'P;�•„jjj1,•P°r 0a � fission # EE 877571 FOF F�� Son ed rough National Notary Assn. COMMISSION NUMBER IZU- NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 JOSEPH E. SMITH, CLERK G' '"HE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3926194 OR BOOK, 5 PAGE 262, Recorded 02/18/2014 at 48 PM NOTICE OF COMMENCEMENT TO BE COMPLETED WHEN CONSTRUCTION VALUE EXCEEDS $2,500.00 OR WHEN HEATING OR AIR CONDITIONING REPAIR OR REPLACEMENT EXCEEDS $7,800.00 PERMIT TAX FOLIO #:1312-SOT-004o-Ooo-2. State of Florida, County of Indian River, the undersigned hereby dives notice that Improvement will be made to certain real property, and In accordance with chapter 713, Florida statutes, the following information is provided in this notice of Commencement. 1. LEGAL DESCRIPTION OF PROPERTY (AND STREET ADDRESS IF AVAILABLE): 47o3 15a*1c Dr. HoC�la.. P,'-e r 5 / D - Pius - rl - R - f_ot 237�Mn� ► 3/i;Ni oll 69 5 - 269 2� rar} P; � a4ar,a 2i�-e 2. GENERAL DESCRIPTION OF IMPROVEMENT: ��T T-� 3. 2OWNER INFORMATION or ❑LESSEE INFORMATION (If Lessee contracted for the Improvement) a. Name: _ &PraIA DenTulie Address: N7m F aale M. Fl;xl• Akue Fr_ 34951- 2 3re9 b. Interest in property: c. Name and address of fee simple title holder lit other than owner): 4. CONTRACTOR: a. Name: So,nka 9cagr,a f t_L Address: !Rn. ?� qx &Sooji: Vera �aCl� Ft 32965 b. Phone number. (77m) 251- 1933 S. SURETY COMPANY (IF Applicable, a copy of the payment bond Is attached): a. Name & Address: b. Phone number. Bond amount: 6. LENDER/MORTGAGE COMPANY: a. Name & Address: b. Phone number. 7. PERSONS WITHIN THE STATE OF FLORIDA DESIGNATED BY OWNER UPON WHOM NOTICES OR OTHER DOCUMENTS MAY BE SERVED AS PROVIDED BY SECTION 713.13 (1) (a) 7., FLORIDA STATUTES: a. Name & Address: b. Phone number fax number. 0. IN ADDITION TO HIMSELF OR HERSELF, a. Owner designates of to receive a copy of the lienor's notice as provided in section 713.1311)(b), Florida statues. b. Phone number., 9. EXPIRATION DATE OF NOTICE OF COMMENCEMENT: (THE EXPIRATION DATE IS ONE (1) YEAR FROM THE DATE OF RECORDING UNLESS A DIFFERENT DATE IS SPECIFIED). WAIIHINGTO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHATTER 713, PART L SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. UNDER PENALTIES OF PERJURY, I DECLARE THAT I HAVE READ THE FOREGOING AND THAT THE FACTS IN IT ARE TRUE TO THE BEST OF MY KNOWLEDG D BELIEF (SECTION 92.525, FLORIDA STATUTES 6. S AT WER or SF,E or R AUTHO ED OFFICER/DIRECTOR/PARTNER/MANAGER Owner SIGNATORY'S TITLE/OFFICE fuo THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS *2 DAY OF rlua 20j BY: Gerald DeCLILAIin NAME OF PE N PE OF AUTHORITY NAME OF PARTY ON BEHALF OF WHOM INSTRUMENT WAS EXECUTED PERSONALLY OW! OR CIPRODUCED IDENTIFICATION TYPE OF IDENTIFICATION PRODUCED SIGNATUR n 0. DANIEL SOROKANOTARY NOTARY PRINTED NAME. N Noury PBWk • SUte of FbrMsMy Comm. Expires May 19.2014Commission 0,81N."o I DD M720 STATE If FLORIDA ST. LUCiE COUNTY THIS iS TO CERTIFY THATTHIS IS TFWE AxlW CORRECT COPS' 0,F T14E or.16 . J0 CL By:. q Y Date a Wier" '014 02/26/2014 20:00 FAX Planning & Development Services Building & Code Regulation Division 2300'Virginia Avenue Fort Pierce, FL 34982 772-462-2155 or 772-462-2172 Fax;772-462-6443 ROQF.INSP CT]ON AFFIDAVIT Re: permit# SK IHOZ-02140 1, . DlkI 5'kCa a . licensed as a(n ontractor* Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual cerCU1Gd under 468 F,S. to make such an inspection. on or about _ 2_-_1$ -14 -- , I did personally inspect the Mgf g%R 011i (Date) work at: 4 703 &a le ID c. R F i-rc-e FL b site address) Based upon that examinap6n I hav determined the Installation was done according to the Hurricane Mitigation Retrofit Vanu I (Bas on 553,844 F.S.) re an :-cCC1330Q05 License # STATE OF FLORID COUNTY OF I ..r Sworn to sn subscribed be re me this - day of 2 by Who Is personally known to me q who has produced 1 JAL _ '5e0 _ / -7a62-0 as identification. Notary Public, State of Florid Signature of Notary: ill(.. Commission Number: (Seal) En 01/19/2011 KflOt,f fffi vewM Pak • f "of Hold, • fly emm. how Jrl 0, 2017 Ca19MMi✓ " * FF 096130 ON400 1WW 11100 AM RECEIVED FFB 2 7 2014 Planning & Development Services Building & Code Regulation Division 2360 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # SLC I° HOZ a 021 Ga I, Daniel Sod: a ka , licensed as a(n ontractor* Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual certified•under 468 F.S. to make such an inspection. On or about 2 " I `d _ I , I did personally inspect the roof deck nailing (Date) work at: 4 703 Eagle 'Or. RRt ce , f Z 3 q9 S 1 (J b site address) Based upon that examina ' n I hav determined the installation was done according to the Hurricane Mitigation- Retrofit Manu I (Bas on 553.844 F.S.) re an -CCC 1330005 License # STATE OF FLORID COUNTY OF !C 9 17 Sworn to an subscribed before me this day of 20� by t Who is personally known to me o who has produced 1. 20 as identification. Notary Public, State of Florid Signature of Notary: ?^L'- Commission Number: (Seal) En 01/15/2011 l`; �.,y KNELI SPENCER Notary Public - State of Florida • •= My Comm. Expires Jul S, 2017 Commission I FF 026136 �'•�%°f� t. londsd Through N Notary As$n. MIAMNDIADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) wwwaniamidade.eoWbuildlnel Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43659 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Oakridge® Shingle LABELING: Each unit shall bear a permanent label with the manufacturet's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other- purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal- of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provideAn b the manufacturer or its distributors and shall be available for inspection at the job site at the request B ' g Official. This revises NOA# 10-1015.01 and consists of pages I through 4. The submitted documentation was reviewed by Alex Tigera. aPeFovEo N o.:11-0411.03 i te:02/03/16 App : 06/16li l el of 4 --z ROOFING ASSEMBLY APPROVAL Cate Roofing Sub -Category: Asphalt Shingles Materials Laminate Deck Tyve: Wood SCOPE This approves a roofing system using Owens Corning Oakridgeg asphalt shingles manufactured by Owens Corning as described in Section 2 of his Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Descriution Specifications Oakridge® 13 'A" x 39 3/s" TAS 110 A heavy weight, fiberglass reinforced laminate asphalt shingle with continuous Manufacturing bead of sealant. Locations #19 2, 3, 4 Oakridge® 13 '/o" x 39 3/e" TAS 110 A heavy weight, fiberglass reinforced laminate asphalt shingle with dashed bead of Manufacturing sealant. Location 01, 3, 4 MANUFACTURING LOCATION 1. Memphis, TN 2. Irving, TX 3. Savannah, GA 4. Jacksonville, FL EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/RepoDate PRI Construction Materials Technologies OCF-153-02-01 TAS 100 09/22/10 PRI Construction Materials Technologies OCF-152-02-01 TAS 100 09/21/10 PRI Construction Materials Technologies OCF- 15 8-02-01 TAS 100 11/10/10 PRI Construction Materials Technologies, OCF-151-02-01 TAS 100 09/27/10 PRI Construction Materials Technologies OCF-150-02-01 TAS 100 09/21/10 PRI Construction Materials Technologies OCT- 165-02-01 TAS 100 01/07/11 PRI Construction Materials Technologies OCF-170-02-01 TAS 100 06/06/11 Underwriters Laboratories 09NK14530 ASTM D 3462 12/31/09 Underwriters Laboratories R2453 ASTM D 3462 10/11/10 Underwriters Laboratories R2453 ASTM D 3462 11/03/10 Underwriters Laboratories R2453 ASTM D 3462 10/11/10 Underwriters Laboratories R2453 ASTM D 3462 10/11/10 Underwriters Laboratories R2453 ASTM E 108 01/13/11 Underwriters Laboratories R2453 ASTM E 108 10/11/10 Underwriters Laboratories R2453 ASTM E 108 11/03/10 NOA No.: 11-0411.03 M spa C 7Y Expiration Date: 02/03/16 • • • Approval Date: 06/16/11 Page 2 of 4 Underwriters Laboratories R2453 ASTM E 108 10/11/10 Underwriters Laboratories R2453 ASTM E 108 10/11/10 Underwriters Laboratories 09NK14530 TAS 107 (ASTM D 3161) 12/31/09 Underwriters Laboratories O 1 NK44201 TAS 107 (ASTM D 3161) 09/09/02 Underwriters Laboratories IONK13947 TAS 107 (ASTM D 3161) 11/12/10 Underwriters Laboratories R2453 TAS 107 (ASTM D 3161) 10/11/10 Underwriters Laboratories 03NK04954 TAS 107 (ASTM D 3161) 03/07/03 Underwriters Laboratories IONK13947 TAS 107 (ASTM D 3161) 01/28/11 Underwriters Laboratories l 1CA15662 TAS 107 (ASTM D-3161) 05/27/1 l LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. INSTALLATION l . Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 1 15 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail 13, attached. LABELING 1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved". CMILAM�WDAACMO BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 11-0411.03 MIA�IMDADEExpiration Date: 02/03/16 .. ,, Approval Date: 06/16/11 Page 3 of 4 13-1 /4" 1"---- t---11 DETAIL A DETAIL B OWENS CORNING OAKRIDGE WITH CONTINUOUS OR DASHED SEALANT 3/8" ,t --"'-t 2" t--11 END OF THIS ACCEPTANCE IE 5 518" EXPOSURE NOA No.: 11-0411.03 FWLDE coUM Y Expiration Date: 02/03/16 I, , , � Approval Date: 06/16/11 Page 4 of 4 EXTERIOR RESEARCH & DESIGN, LLC. CertiFcate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Allied.Building Products Corp / Evaluation Report A42960.10.12-111 TRI-BUILT Roofing Products FL16048-Rl 9050 Louisiana Street Date of Issuance: 10/25/2012 Merrillville, IN 46410 Revision 1: 08/27/2013 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle.. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by:'Z� - e-aca a: • :� _? Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 08/27/2013 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE. 1. TrinitylERD does not have, nor does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinityleRD Is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for which the evaluation reports are being Issued. 4, Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by Allied Building Products Corp., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, 1507.2.9.2, 1507.3.3, Physical Properties ASTM D1970 2001 1507.5.3 1504.6 Accelerated Weathering ASTM G155 2005 1504.3.1 Wind Uplift FM 4474 2004 1507.3.3 Installation Practice FRSAITRI 07320 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties P33360.06.10 07/01/2010 ERD (TST6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST6049) Physical Properties P33370.04.11 04/26/2011 ERD (TST6049) Physical Properties P369.09.11 09/01/2011 ERD (TST6049) Physical Properties P37300.10.11 10/19/2011 FM Approvals (TST1867) Wind Uplift 3004091 01/12/2000 PRI (TST5878) Physical Properties PUSA-083-02-01 07/01/2008 UL, LLC. (QUA9625) Quality Control Multiple -Listing Agreement 02/27/2012 UL, LLC. (QUA9625) Quality Control Multiple -Listing Agreement 04/12/2012 UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 10/24/2015 4. PRODUCT DESCRIPTION: 4.1 Self -Adhering Underlavmenty: 4.1.1 Tri-Built Granular-P Shingle Underlayment is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.1.2 Tri-Built Tile and Metal HT Underlayment is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.1.3 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand - surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheet width. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part- of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. Evaluation Report A42960.10.12-111 Certificate of Authorization #9S03 FL16048-Rl Revision 1: 08/27/2013 Page 2 of 6 TRINITY ER® 5.3 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AH] for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underlayments are as follows: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes & Slate Shingles Tri-Built Granular-P Shingle Yes No No No Yes Yes Underlayment Tri-Built Tile and Metal HT Yes Yes Yes Yes Yes Yes Underlayment See 5.4.1 Tri-Built Sand-R SA Shingle Yes No No No Yes Yes Underlayment 5.4.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ➢ Tri-Built Tile and Metal HT Underlayment with Polyfoam PolyPro AH160 ➢ Tri-Built Tile and Metal HT Underlayment with Dow TileBond 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: Tri-Built Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT Underlayment applied to: ➢ New untreated plywood; ➢ ASTM D41 primed new untreated plywood; ➢ Existing plywood; ➢ ASTM D41 primed existing plywood; ➢ ASTM D41 primed OSB; ➢ Southern Yellow Pine; ➢ ASTM D41 primed Southern Yellow Pine; ➢ ASTM D41 primed structural concrete; ➢ Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Allied Building Products Corp. does not require priming of new or existing plywood sheathing for use with Tri-Built Granular-P Shingle Underlayment or Tri=Built Tile and Metal HT Underlayment. New or existing plywood sheathing should be cleaned of all dirt and debris prior to application of these TRI-BUILT membranes. Tri-Built Sand-R SA Shingle Underlayment applied to: ➢ Plywood; ➢ ASTM D41 primed plywood. Note: While not required over plywood, Allied Building Products Corp. recommends priming the deck if the final roof cover is not slated for Installation within 24 hours. Note: Allied Building Products Corp. requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.5.2 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in PRSA/TRI 07320 and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. Exterior Research and Design, I.I.C. Certificate of Authorization #9503 Evaluation Report A42860.10.12-Ri FL16048-RI Revision 1: 08/27/2013 Page 3 of 6 TRINITY ERD 5.5.2.1 Maximum Design Pressure = -315 pssf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: ASTM D41 Underlayment: Tri-Built Tile and Metal HT Underlayment. 5.5.2.2 All other direct -deck, adhered TRI-BUILT underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.5.3 Bond -to -Insulation: ➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum -Fiber Roof Board. Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on file systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system In accordance with FM 4470, Appendix K or TAS 114, Appendix J. 5.5.4 Bond to Mechanically Attached Base Layer: ➢ ASTM D226, Type I or II felt. Note: For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on the systems, base layer shall be attached per minimum requirements of FRSA/TRI 0732018-05 or RAS 120. 5.6 Exposure Limitations: 5.6.1 Tri-Built Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT Underlayment shall not be left exposed for longer than 90-days after installation. 5.6.2 Tri-Built Sand-R SA Shingle Underlayment shall not be left exposed for longer than 30-days after installation 5.7 For the roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of 02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems. TABLE 2: TILE SYSTEM OPTIONS PER FRSA/TRI 07320/8-05 System Underlay Option Section Reference Product(s) System One: 5 3.02E Self -Adhered Underlayment Tri-Built Tile and Metal HT Underlayment No. 30 / Self -Adhered Base Layer: ASTM D226, Type II Mechanically Fastened Tile, Unsealed or Sealed 6 3.02E Underiayment Top Layer: Tri-Built Tile and Metal HT Underlayment System Underlayment System Two: 4 3.021) 1 Self -Adhered Underlayment Tri-Built Tile and Metal HT Underlayment No. 30 / Self -Adhered Base Layer: ASTM D226, Type II Mechanically Fastened Tile, Sealed Underlayment 5 3.02E Underlayment Top Layer: Tri-Built Tile and Metal HT System Underlayment System Four "A": 4 3.02D Self -Adhered Underlayment Tri-Built Tile and Metal HT Underlayment No. 30 / Self -Adhered Base Layer: ASTM D226, Type II Adhesive -Set Tile, Unsealed or Sealed Underlayment 5 3.02E Underlayment Top Layer: Tri-Built Tile and Metal HT System Underlayment 3 3.02C Self -Adhered Underlayment Tri-Bullt Tile and Metal HT Underlayment System Four "B": No. 30 / Self -Adhered Base Layer: ASTM D226, Type II Adhesive -Set Tile, Sealed Underlayment System 4 3.020 Underlayment Top Layer: Tri-Built Tile and Metal HT Underlayment Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report A42960.10.12-Ri FL16048-R1 Revision 1: 08/27/2013 Page 4 of 6 TRINITY ER® 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with Allied Building Products Corp. / TRI-BUILT published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Tri-Ruilt Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT Underlayment: 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For non -tile applications: 6.3.2.1 Back -nail selvage edge seams in accordance with the Allied Building Products Corp. / TRI- BUILT Back -Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. The head lap membrane is to cover the area being back -nailed. 6.3.2.2 All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Tri-Built Tile and Metal HT Underlayment, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). Seam: Tri-Built Underlayment 6.3.2.3 Install to ensure full contact with approved substrates. Allied Building Products Corp. / TRI- BUILT require a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.3.3 For tile applications (Tri-Built Tile and Metal HT Underlayment only): 6.3.3.1 Reference is made to Section 6.3.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.4 Tri-Built Sand -lit SA Shingle Underlayment: 6.4.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non -tile applications: 6.4.2.1 While priming is optional, Allied Building Products Corp. recommends priming the deck if the final roof cover is not slated for installation within 24 hours. 6.4.2.2 Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report A42960.10.12-Ri FL16048-RI Revision 1: 08/27/2013 Page 5of6 TRINITY ERD 6.4.2.3 Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. 6.4.2.4 Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. 6.4.2.5 Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps. shall be sealed using either heat -welding or hot air welding techniques. 6.4.2.6 When installing at slopes above 8:12, Allied Building Products Corp recommends back -nailing in the overlap area at the top of the sheet at 12-inch o.c. 6.4.2.7 For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL, LLC - QUA9625; (314) 578-3406; k.chancellor@us.ul.com Exterior Research and Design, LLC. Certificate of Authorization #9503 - END OF EVALUATION REPORT - Evaluation Report A42960.10.12-111 FL16048-RI Revision 1: 08/27/2013 Page 6 of 6