Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSFEES DUE: RECEIPT 11. Location/Site Address: Pernut #: Planning & Development Services Departn Building & Code Regulation Division 2300 Virginia Avenue Ft Pierce, FL 34982-5652 Tel. 772462-1553 �,Jn hAPPLICATION FOR ,yROOF nPERMIT / , 4 ,!AVERSE _ UC 2. Parcel 11D Number: ent Office Use Only Section Township Range Ma Page Zoning Land Use Initials 0 3. Description of Project or Work Activity: Od g 4. Total Roof Area (square feet): 5. Roof Pitch: 6. Type of Roof [ 4/Fiberglass Shingle [ j Concrete Roof Tile 0i' [ j Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [ J Other [ 4/Product Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached * Roof Mitigation per F.S. 553.844 will be required. . 7. Owner Information /� Q 8. Contractor Information p 14 Name- �%%/ �4 CCCC f'CC� �/'I� FL Reg/Cent #: 1/7 Address: Off% of %lf ✓Z/i� County Cert #: City: Stater Business Name: C( ,ZD 127C Zip: "% Phone: o• 7" 9�0 Cell Phone: 72 �7� 7 c� 9. Value of Construction: $ Z Y00 , co _ "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTORIOWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. PIUNIT QUXLME T WNERSNANX , ' 7 S1G&ATUpjyOF QU LIFIER/OWNER STATE OF FLORIDA, COUNTY OFF �rPP ACKNOWLEDGED BEFORE ME DAY OF 20� BY WHO IS PERSONALLY KNOWN TO ME OR HAS PRODUCED AS IDENTIFICATION ers ilpA wry ^ Gov Pro���ij� SIGNAT OF NOT TYPE OR P NAME OF NOTAIIY : a? �' l l COMMISSION NUMIiE � C ''}''F' • - ��" EXPIRES April 20'i4 (407) 398-0163 FloridaNnt9rySerlia:.cor! NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3926092 OR BC 3604 PAGE 2956, Recorded 02/18/2014' 10:05 AM NOTICE OF COMMENCEMENT Tole completed wAen construction value exceeds $2,500.00 PERMIT /: TAX FOLIO a 1423-802-0002-230-9 STATE OF FLORIDA COUNTYOF The undersigned hereby gives notice that Improvement will be made tocertain �real property, and in accordance with Chapter 713, Florida Statutes, the following Information Is provided In this Notice of Commencement. LEGAL DESCRIPTION OF PROPERTY (AND STREET ADDRESS, IF AVAILABLE): 3405 N. AtA Fort Pierce Fl. 34957 SECTION: 23 TOWN: 34S RANGE 40 E GENERAL DESCRIPTION OF IMPROVEMENT: RE -ROOF OWNER INFORMATION OR LESSEE INFORMATION, IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name: JOHN & PAULA_HORNER Address: 3405 N. FORT PIERCE FL. Interest in property: RESIDENCE Name and address of fee simple title holder (If different from Owner listed above): CONTRACTOR'S NAME: GARY MAR20, INC. Phone No.: (772) 871-2489 Address: 861 A- SW LAKEHURST DRIVE .PORT SAINT LUCIE FL. 34983 SURETY COMPANY (if applicable, a copy of the payment bond Is attached): Name and address: Phone NO., Bond amount: LENDER'S NAME: Phone No.: Address:._ Parsons within the State of Florida designated by owner upon whom noUces or other documents may be served as provided by Stolen 713.13 (1) (a) 7, Florida statutes: Name: Phone No.: Address. In addition to himself or herself, owner designates of tr receive a copy of the Llenor's Notice as provided In Section 713.13(d)(b), Florida Statues. Phone number of person or entity designated by Owner: Expiration date of Notice of Commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date Is specHled): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I. SECTION 713,13. FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPRQVEMEN75 TO YOUR eQQPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST Under perialty of per ury,1 deda tre hat I have ad the foregoing and that the facts In It are true to the best of my knowledge and belief. �e, /JUl *� Owner or lessee, or Owners arlassee'e Authorized l>ffimr/Director/ParMer/Manager/AttOrney4n-fa0 Slimatory's Thle/Office ''yyrr The f9regoing Instrument was Acknowledged before me this I day of 20 I ✓ 1 By: I as l W 1 K� for �1 e f person n Type of authorhy (e.g. officer, trustee) Parry on behalf of whom Instrument was executed Personalty known 4orproduced Identification 13 Type of Identification produced (Prim, Type,-OrStamp Com?n9loned Name of Notary) T:1BID1Btdg FormsWewApplicationalFannsWaticeOfCammencement.Doez MARY SWEARINGEN •, N""'!o;Notary Public - State of Florida �v.9/ISIt I My Comm. Expires Jun 7, 2016 Z.•, Commission # EE 183732 Bonded Through National NotaryAssn. STATE OF FLORIDA ST. LUCIE COUNTY THIS IS TO CERTIFYTHATTHIS IS A TRUE AND CORRECT COPY O THE ORIGINAL oica—P Ile U 'f FEBO v 2014 Date: FloridairBuildiag Code Online i r • r.r,ng.org/pr/p.rr • r r. .r � 3 ��• � T +� � �a,� � ., ,, r � s +� � `�' ,,;Y. ��rr..rgtt�c-, �Acau',r n��r� paPp u+�s , �{>31.:. "r •. -r. . 13CIS Home Log In User Registation Hot Topics, Submit Surcharge Stats & Facts Publications FBC Staff BCLS Site Map Unks Search 'us ne§ Product Approval Protssj Vkal 'eI1 Llccnsc egtfi`cimtly Regulate (a:dy, - a ?-Application Detail 6FGfLfN�1ri5 ✓ . Code Version0 1 •pApproved Comments ArchIved Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality, Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Testing Lab Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced. Standard and Year ) Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg. keel er@owenscornI ng.com Greg Keeler greg.keel6r@owenscornIng.com Roofing Underlayments Test Report PRI Construction Materials Technologies, LLC Underwriters Laboratories Inc. 03/08/2015 Robert]. M. Nieminen, PE Validation Checklist - Hardcopy Received FL9777 R2 COI PRI cert of indeoendence.odf Standard Year ASTM D 1970 2001 Equivalence of Product Standard Certified By I affirm that there are no changes In the new Florida Building Code whlch affect my product(s) and my product(s) are In Compliance with the new Florida Building Code. Documentation from approved Eva n or Validation Entity Yes No N/A 1 Of 2 9/23/2013 9:55 AM Floridz Building Code Online http://www.florida Hng.org/pr/pr_app_dtl.aspx?param=... Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option B 02/01/2012 02/01/2012 03/31/2012 .7ummarIF Vr rrU UY FL # Model, Number or.Name Description 9777.1 Weather Lock Metal Weatherproofing Underlayment Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: 1.) This Approval is not for use with] n-HVHZ. 2.) Shall be Installed In accordance published installation Installation. Instructions FL9777 R2 II Install weatherlockmetal.pdf . FL9777 R2 II Technical Bulletin - WeatherLock over the entire deck2.pdf Verified By: Robert Nieminen 59166 Test Reports FL9777 R2 TR PRI WeatherLock Metal ASTM D1970.pdf Instructions and FBC non-HVHZ requirements. 9777.2 Weatherlock G Weatherproofing Underlayment Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: 1.) This Approval is not for use within HVHZ. 2.) . Shall be installed in accordance published installation Installation Instructions FL9777 R2 II Install weatherlock G and MAT.ndf FL9777 R2 II Technical Bulletin - WeatherLock over the entire deck2.odf Verified By: Robert Nieminen 59166 Test Reports. FL9777 R2 TR PRI NEI0240201 ASTM D1970.pdf I nstructions and FBC non-HVHZ requirements. 9777.3 Weatherlock MAT Waterproofing Underlayment Limits 'of Use Approved.for use in HVHZ: No. Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: 1.) This Approval not for use in the HVHZ. 2.) Shall be Installed in accordance with published installation Instructions subject to FBC non-HVHZ requirements. 3.) Installation Instructions FL9777 R2 II Install weatherlock G and MAT.pdf FL9777 R2 II Technical Bulletin - WeatherLock over the entire deck2.1)df FL9777 R2 II weatherlock mat 4i n deck taoe2.pdf Verified By: Robert Nieminen 59166 Test Reports FL9777 R2 TR PRI WeatherLock MAT ASTM D1970.pdf Minimum slope 1:12. 4.) Shall not be installed over existing roofing materials. 5.) Substrate shall be clean,. smooth and dry. Back N.- Contact Us :: 1940 R^rt" ""onroe Street Tallahassee Fl. 32399 Phone: 850-487-1824 . The State of Florida Is an AA/EEO employer. Copyright 2007-2010 State of Florkia ;:Privacy Statement:: Accessibility Statement ::Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic mail to this entity. Irstead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department wittran email address if they have one. The emalis provided maybe used for official communication with the licensee. However email addresses are public record. If you do. not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under - Chapter455, FS., please click here . Product Approval Accepts: ® aCNI'ItYM L:rx:C :s ' z.of 2 9/2.3/2013 9:55 AM MIAMI-acne ® MIAMI-DADE COUNTY • PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miRmidade.gov/building/ Iko Industries Ltd. 40 Hansen Rd. S. Brampton, Ontario CANADA L6W3H4 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Cambridge AR LABELING: Each unit shall bear a permanent following statement: "Miami -Dade County Pr6d RENEWAL of this NOA shall be considered change in the applicable building code negath TERMINATION of this NOA will occur after t: materials, use, and/or manufacture of the product product, for sales, advertising or any other purpo: with any section of this NOA shall be cause for tE ADVERTISEMENT: The NOA number precede the expiration date may be displayed in advertising with the manufacturer's name or logo, city, state and pntrol Approved", unless otherwise noted herein. ,al application has been fled and there has been no the performance of this product, ttion date or if there has been a revision or change in the Iss. Misuse of this NOA as an endorsement of any automatically terminate this NOA. Failure to comply ih and removal of NOA. )rds Miami -Dade County, Florida, and followed by If any portion of the NOA is displayed, then it shall be done to its entirety. INSPECTION: A copy of this entire NOA shall be provid o the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 10-0913.02 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 11-0517.09 Expiration Date: 05/05/16 Approval Date: 07/07/11 Page 1 of 4 i ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Cateaorv: Asphalt Shingles Materials Laminate Deck Type:, Wood SCOPE This approves a roofing system using Cambridge AR asphalt shingles manufactured by IKO Industries Ltd. as described in Section 2 of his Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Specifications Cambridge AR 13 3/4" x 40 7/8" TAS 110 MANUFACTURING LOCATION l . Kankakee, IL EVIDENCE SUBMITTED Test Anency PRI Construction Materials Inc. FM Approvals FM Approvals FM Approvals Product Description A heavy weight, fiberglass reinforced laminate asphalt shingle. Test Identifier Test Name/Reyort Date IKO-050-02-01 TAS 100 12/21 /09 3041689 ASTM D 3462 02/23/11 3036971 ASTM D 3161 -(TAS-107) 01/04/09 3042673 ASTM E 108 04/12/1 l LIMITATIONS I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail'B', attached. NOA No.: 11-0517.09 Expiration Date: 05/05/16 Mie a�an; COUNTYExpiration Date: 07/07/11 Page 2 of 4 LABELING 1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved". BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 11-0517.09 Expiration Date: 05/05/16 Approval Date: 07/07/11 Page 3 of 4 DETAIL A CAMBRIDGE AR COURSE LAYOUT OF ROOF 30" Note: Roofing Cement not shown in this layout. This drawing is for course layout only. See Detail B _ __ _ _ _ _ _ _ _ _ _ for nailing and cement placement details. 20 THIRD COURSE FIRSTCOURS 003/3 DETAIL B CAMBRIDGE AR 40 7" -71 13 4" 6 8'l 5 e" EXPOSURE END OF THis ACCEPTANCE NOA No.: 11-0517.09 MMI-DADECOUNTYM Expiration Date: 05/05/16 Approval Date: 07/07/11 Page 4 of 4