Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS-- I I DATE: I FEES DUE: I RECEIPT #: I Permit #: ." t) 1 l d Planning & Development Services Department Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel. 772-462-1553 APPLICATION FOR ROOF PERMIT SEE REVERSE SIDE FOR INSTRUCTIONS 1. Location/Site Address: 6904 Sebastian Road 2. Parcel ID Number: 1301-613-0311-000-2 St. `UC/O C0%nty Office Use Only ownship Range Map Page Zoning Land Use Initials 3. Description of Project or Work Activity: Re -Roof Remove old felt & shingles, renail decking, reinstall new 30# felt & OC Shingles 4. Total Roof Area (square feet): 2800 5. Roof Pitch: 5/12 6. Type of Roof: K4Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other [Product Approval required for all types of Roofing Material (2 Sets) ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Info><mation 8. Contractor Information Name: Carleton H. Sheets JR) Vasil Mihaylov Address: 6773, SE N Marina Way City: Stuart State: FL Zip: 34996 Phone: 834-1904 9. Value of Construction: $ 7650.00 FL Reg/Cert #: CCC1330234 County Cert #: '�Q ?507 Business Name: RBZ Roofing J(Phone: 407-330-7663 * "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. �� Debra A. Dean i�l14— a PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF eY1n ACKNOWLEDGED BEFORE ME THIS 10t'-DAY OF t�OZ 20 14 , BY 0(,19(L yeah_- - - - - - - RACHEL HELM IS PERSO A LY KNOWN TO ME OR HAS PRODUCED Fi, p� VV AS IpF N I ;ONotary Public • State of Florida �� i : . . •: My Comm. Expires Dec 27, 2017 S NATURE O NOTARY TYPE OR PRINT NAME OF NOTARY (seal) �F Commission N FF 072188 d`' @e0tlsd 1kao National Notary Assn. COMMISSION NUMBER ® 12-1 NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 r - i Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # I, Debra A. Dean , licensed as a(n)Contractor*/.Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about I did personally inspect the roof deck nailing (date) work at: 6904 Sebastian Rd. (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) iz&LQ n Signature and Seal STATE OF FLO IDA COUNTY OF CCC 1330234 License # Sworn to and subscribed before me this NJ'- day of T t'i% LUM 2014 by DPiprcL peAm Who is personally known to me or who has produced jti hL as identification. Notary Public, State of Florid j,� Signature of Notary: Commission Number: (Seal) RACHEL HELM •�a'a� °�A�4 :�• I s Notary Public - State of Florida En 01/19/2011 e • : : • My Comm. Expires Dec 27, 2017 i'�„as ••�� = Commission r FF 072188 •�• BMW 71tratrdtNational Notary Mn. TRINITY, ER® EVALUATION REPORT C,tXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 -a-553 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Owens Corning Evaluation Report 037940.02.12-112 One Owens Corning Parkway FL10674-RS Toledo, OH 43659 Date of Issuance: 02/06/2012 Revision 2: 12/19/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 12/19/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named dient CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products It evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. TRINITY I ER® ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 3. REFERENCES: ti Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12 02/14/2008 Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12 12/16/2009 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03 06/16/2011 Miami -Dade (CER1592) FBC HVHZ Compliance 12-0309.01 07/19/2012 UL LLC (QUA9625) Quality Control Service Confirmation R2453 Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic® and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Duration°, TruDefinition® Duration®, Duration° Premium Cool, TruDefinition° Duration° Designer Color Collection, TruDefinition° Oakridge®, Oakridge° and WeatherGuard° HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard° HP Hip & Ridge Shingles and ProEdge Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R2 CertiFcate of Authorization #9503 FL10674-RS Revision 2: 12/19/2012 Page 2 of 6 TRINITY j ERD 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.2 All Owens Coming hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (Vuit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire° shingles require minimum five (5) nails per shingle. ➢ WeatherGuardO HP shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing — Classic@ & Supreme: NormMansard or Aron pars Wind TransAHigh Wind desvanes y Area pare vientos nortmafes Areas vientos tuarres t' IA► t' rt. a Ie rz. t. 5•Exposure ExposicfSn Exterior Research and Design, LLC. Certificate of Authorization #9503 Normal Mansard or Area porn Wind Areas =Wind doavartas y Ana pars viontos normal�a Araoa viontos /uartes tat tat 1 5 51W Exposure Expasicidn Evaluation Report 037940.02.12-112 FL10674-118 Revision 2: 12/19/2012 Page 3 of 6 6.2.6 Minimum Nailing - Berkshire@: TRINITY I ERD sealant Strip La rha de sdra&r r 8 Yf 8 Yf 8 Yf 8 Yf P 1 1 Z" Asphakroofngt Cer "fo da tnhode aslaho 6.2.7 Minimum Nailing - Duration@, TruDefinition@ Duration, Duration@ Premium Cool & TruDefinition° Duration° Designer Color Collection: 4tt—.W Slt.p Skp 6Nal rtntendtood tare. Pattern �fII areaabdwmstou. a/na Gbnanib amiled" dt 6davos a�ixifrpda to a d • • • 1naSweHaNTbiane —1 fQaetu,rtdraak. SM1310 \ S..%( osttrirorol1 tntmo7 atnalln ` anan�ae Araade 1' su IU7a 1t ` • 12" su.-WIP SV Expowre Nam 5V Exposure 5ssptdg. de apos(cdin Cfaws 51.11 pufg. do eipesidtin 6.2.8 Minimum Nailing - TruDefinition° Oakridge@, Oakridge@: 4 Nail Pattam Espema con 4 davos r r I<— tz• 65/8"EnPosure� 55f8"Exposure Erposfddnde56/Spufg. Claw Exposfckn de 6GIG ptdg. Exterior Research and Design, LLC. Certificate of Authorization #9503 6 Nail Mom Espema eon 6 davos r t• tr --)H 551T Exposure Cllaaws 5 518' Exposure fgposiddn de 66/8 ptdg. Expasf=n de 56/8 ping Evaluation Report 037940.02.12-112 FL10674-R8 Revision 2: 12/19/2012 Page 4of6 6.2.9 Minimum Nailing — WeatherGuard@ HP: wafts e 6.3 Hip & Ridge Shingles: TRINITY ! ER® 6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard° HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire@ Hip & Ridge and High Ridge: Fig.1 4 t-- PrevalingWnd Direction A A Nags 4 / I I A I I A I I JQ I I I I I I i i i r �s� posipe 6.3.4 Minimum Nailing — Hip & Ridge with Sealant: em Fig. 2 - High Wind Fastening Pattem K Nails) rnn Shingle and Discard 2" 2" Excess 1" 1" Sealant —� Strip 12" 'Fastening 55/E' 5"Exposure Distance 12" Exterior Research and Design, LLC. Certificate of Authorization #9503 Fig. 2 Top View SideMm Nags ( Nails r Top Laminated 2' 1 4' Pie[ I I ml I �I 1 �I I I I I I Evaluation Report 037940.02.12-R2 FL10674-118 Revision 2: 12/19/2012 Page 5 of 6 6.3.5 Minimum Nailing — WeatherGuard® HP Hip and Ridge: Fig. A q q Prevailing Wind �— Direction A A Halls q q A p I I q I I 1 I I I A I I I A I I I I I I I I Erposuro +` TRINITY i ERD Fig. C Hip & Ridge Shingle Fastening TopVbei Naps NaIL T' 7' 2" 1° 1' G. Exposure 'I 12' ry 6.3.6 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Wind Direction Sealant Strip A---'- 6' Exposure J 7. LABELING: Fasten 7'h' Cover Exposed Fasteners with Roof cement Standard Fastening Pattern 1244,Sealant 7- 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625 ; (414) 248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12-112 Certificate of Authorization #9503 FL10674-RS Revision 2: 12/19/2012 Page 6 of 6 JOSEPH E. SMITH, CLERK OF,T__HE CIRCUIT COURT — SAINT LUCIE COUNT` _ FILE # 3926880 OR BOOK PAGE 1962, Recorded 02/20/2014 at 18 AM THIS INSTRUMENT PREPARED BY: Name: RBZ Roofing, Inc. Address NOTICE OF COMMENCEMENT Permit Number. Parcel ID Number. 1301-613-0311-000-2 The undersigned hereby gives notice dud Improvement will be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the following Information is provided in this Notice of Commencement. �ddr I. DESCRIPTION rk PROPERTY: (LegeO Ld otnT2 (MA �/�1 ( � tz92� If available) Lakewood Park -Unit 11 - BL 1 b 6904 Sebastian Road :L GENERAL DESCRIPTION OF IMPROVEMENT: RE -ROOF 3 OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address; Carleton H Shhets (TR) Vasil Mihaylov r((Xa%lifii property: _6773 SE N Madan Way, Stuart FL 34996 Fee Simple Title Holder (if other than owner listed above) Name: Address 4. CONTRACTOR: Name: RBZ Roofing, INC Plane Number.. 407-MO-7663 Address: 1210 Central Park Dr. Sanford FL. 32771 S. SURETY (If applicable, a copy of the payment bond Is attached): Name: AddreSs: Amount of Bond: & LENDER: Name: Phone Number. Address: 7. Parsons wNhln the State of Florida Designated by Owner upon wham notice or other documents may be served as provided by Swoon 713.13(1Na)7., Florida Stahrtas. Name: Phone Number. L In addition, Owner designates of to receive a copy of the Uenors Notice as provided in Section 713.13(1)(b), FWda Statutes. Phone member. 9. Erpketion Date of Notice of Commencement (The eaprroaon is 1 year horn date of recording unless a dinerenl date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 710, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORKOR RECORDINGYOUR NOTICE OF COMMENCEMENT. Urmettles ]fPedu I declare that I have read a foregoing and that the facts stated In it are true to the bast of my knowledge and t/�wu-aasaonanunworeru�M i ti V�Nf�'° L� oaui State of —^F 24 County of S/. ZC; e The fo/h•r��it�W�1•ng Instrum en t was a c knowledge �d /before .,ft�hI O- day of _- b r VA./` �e by l.6CI��d Al tCPiS {' (/a�i�//` tom/— Who is personalty known to me, M"OR wen. of gaffer raceme ruw�ra / who has produced Identification 17 type of IdemHi^�eation produced: f� //el ✓PO'S �C. eC A,.ce CAT;HYLUEDKEMY COMN NFF009165 (407139a-0153 FloridaSamlce.com STATE OF FLORIDA ST, LUCIE CONTY 'rmi6 ( 'I') AND CERTIFY THATTRig t.6 A IR.UE AI�AlflREC (,COr" f O THE 0fl,I2P�IA JOcrcPf E. 8MITH, QLlRK RBZ Roofing "Where Quality Coates First" Licensed & Insured State Certified # CCC1330234 1210 Central Park Dr. Sanford, Ff. 32771 Ph: 407-330-7663 Fax: 407 330-7661 FAX COVER SHEET February 17, 2014 St. Lucie County Building Department 772-462-6443 Attached please find our applieation for a re -roof permit for 6904 Sebastian Road. The recorded NOC will be delivered to you when we come to 13U the permit. � • � Please lot the kaow the amount due for the permit so that I can write the check. �� �� Thank You, L-bR Debra A. bean Q dOG / � ¢y�r�itd2 //C//,z 0/ 41 /--O'?11.5 DATE: I FEES ISM I 1ItiEd - T #: T Permit #: Planning & Development Services Department Building & Code Regulation Division • 2300 Virginia Avenue Ft Piettc, FL 34982-5652 Tel. 772-462-1553 APPLICATION FOR ROOF PERMIT SEE RE ESE SIDE FOR INSTRUCTIONS 1. Location/Sete Address: 6904 SeK!*gliaaJRaad 2. Parcel ID Number: 1301-613-0311-000-2 Office Use Only Section Township Range I Map Page .Zon-1—a Land Use I Initials 3. Description of Project or Work Activity: Re -Roof Remove old felt & shingles, renail decking, rainatall new 30kfelt and 00 ahinglos. 4. Total Roof Area (square feet): 2800 6. Type of Roof•. [Fiberglass Shingle [ ] Tar & Gravel 5. Roof Pitch: 5/12 [ I Concrete Roof Tile [ I Wood Shake / Shingle [ } Modified )Bitumen [ } Other NO roduct Approval required for all types of Roofing Material (2 Sets) [ } All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. $53.844 well be required. 7. Owner Information 8. Contractor Information Name: Carleton M. Sheets. (IR) V@ail Mihaylov Address: 6773 CF M 44arina War City: Stuart - State: EL Zip: 349913 Phone: 834--1904 Ft Reg/Cert #: CC.CJM02M County Cert #: Business Name: RAZ Roofing I Plb01IC- 407-43ftJ6&-: 9. 'Value of Construction: S 7660.00 "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CON 1'RACTOid/OWNER'S A,F)FIDA"T: I certify that all ofthe information contained in this application is Correa and that off work will be done in compliance with all applicable laws regulating construction and zoning. Dehra A Des ►►,&DJuo- .d "" -I'l, PRIN 1' QUALTP' AS/O`(vNERS NAME SIGNATURE OF QUALIFIER/OW NER STATE OF FI OR WA, COUNTY OF ACKNOWLEDGED BEW99 ME IBIS DAY OF 20 . BY VMO IS PERSONALLY KNOWN __" ME OR AAS PRODUCER _ _ _ _ _ -- AS IDEN7V ICAT1ON SIGNATURE OF NOTARY _ 'I"MP E OR PRCNT NAME OF NOTARY (staff) COMMISSION NUMBER ... NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY REsuLT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR JPROPERTY. IF YOU INTENT) TO OBTAIN FINANCING, CONSULT YOUR LENDER Olt ATTORNEY BEFORE RECORDING YOTJR NOTICE OF COMMENCEMENT. Revised 4/26/2010 { - EXTERIOR RESEARCH & DESIGN, LLC. Certifltato ofAuthorizdtion #9503 TRINITY ' ERD CT 353 CFIRISTIA OXFORD, 0678 478 PHONE: (203) 262-9245 FAX:(203) 262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940,02.12-R2 One Owens Corning Parkway FL10674-R8 Toledo, OH 43659 Date of Issuance: 02/06/2012 Revision 2: 12/19/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials In the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P-E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LARPLING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED CoMPIf_tANce: This Evaluation Report Is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product Change, Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERl7 requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPEcrrom: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M_ Nieminen, P.E. ;1%��;��a,,�,;.• Florida Registration No. 59.166, Florida DCA ANE1983 The fatstmlle seat appearing was authorind by Robert Nleminen, PA M 1.211917012 This does itot genre as an eleEMMICally signed docudknt• signed, sealed hardcoples have been rraDsmitmo W the PtWUa Approval Admloisorator and to d,a named client CCRiYFWATYON OF INDEPENDENCF: i. TrinitylERD does not have, nor does it Intend to acquire or will It acquire, a financial interest in any company manufacturing or distributing produdtS it evaluates. 2. TrinitylERD Is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products Ibr which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a IYnanclal interest In any other entity involved In the approval process of the product. :M1 TRINITY; ERD ROOT-ING WSTEms EvAujATiom 1. SCOPE; Product Category: Roofing guh-Category: Asphalt Shingles Corpliance Statement., Owens Coming Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. $TANDARDS: -5��—SMP�4 xgJU 1507.2..R905.24 Physical Properties AST 3662 2007 1507.2.7,1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2006 2O07 3. REFERENCES: I Examiinatioli R1fftE9 ce —M UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/1!i/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 Ut.LLC (TST9628) Physical Properties 0SCA20263 XICA34308 04/18/2006 02/18/2012 UL LLC (T-ST9628) Wind Resistance Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116,12 02/14/2000 Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915-12 12/16/2009 Miami -Dade (CEP1592) FBC HVHZ Compliance 10-0817.09 10/27/2010 10/27/2010 Miami -Dade (CER1592.) FSC HVHZ Compliance 10-0817.10 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08 10/27/2010 Miami -Bade (CER1592) FBC HVHZ Compliance 10-0817.07 10/27/2010 06/16/2011 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03 Miami -Dade (CER1592) FBC HVHZ Compliance 12-0309.01 07/19/2012 UL LLC (QUA%25) Quality Control Service Confirmation R2453 Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 ClassiCO and Supreme® are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1-2 Berkshire% are fiberglass reinforced, 4-tab asphalt roof shingles- 4.1.3 Duration°, TruDefinitiong Duration°, DuratlonO premium Cool, TruDeRnition® Duration' Designer Color Collection, TruDefinition® OakridgeO, 0akridgeQ0 and WeatherGuard® HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshires Hip & Ridge Shingles; High Ridge, Hip & Ridge with Sealant, WeatherGuardo HP Hip & Ridge Shingles and ProEdge Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4,3 Starter Strip Plus and Starter Shingle Roll are starter Strips for asphalt roof shingles. 5. LIMUATIONS. 5.1 This Evaluation Report is not for use In the HVH7. 5.2 Fire Classification is not part of this Evaluation Report, refer to current Approved Roofing Materials Directory for fire ratings of this product, 5.3 Wind Classification: Exterior Research and Dooigxt, LLC. F-valuntion Report O37940.02.12-R2 ce"ceee ofAutharJshtlpn #9303 FL10674-RS Revision 2., 12/1912012 Page 2 of 6 i TRINITY i ERD i 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R9o5.2_fi_1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to V,:d = 150 mph (V„ir = 194 mph). Refer to section 6 for installation requirements to meet this wind rating. 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus Noted herein are Classified in accordance with F13C Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us In all wind zones up to Vasd = 150 mph (V„ it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published Information on wind resistance and Installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3_ 6. INSTALLATION: 6.1 Underlayment. 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire& shingles require minimum five (5) nails per shingle. > WeatherGuard® HP shingles require minimum six (6) nails per shingle. > Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Coming published Information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. contact the shingle manufacturer for details. 6.2.5 Minimum Nailing — Classic® & Supreme: lfon wt Mtwwwd or Ampm VI M Ansss H(a~. Mind d+ r Aira prn dante7 na/mafa* A . Vi..•rea SEYpay�n. Exterior Research and Design, LLC. Ce,► flcare of AvMoiftWon #9503 NUFMA M. tftd of Ar" pen VVI M Are! Hipp VMW d�s►wns r Ar p" vlanna PO—Mt—Awu viserea fwrt 1 W r � s• �. 6 QJ$• F,apowrss lnpa>ia7&. Evaluation Report 037940.02.12-R2 FL10674-RS Revlsion 2: 12/19/201:1 Page 3 of 6 6.2.6 Minimum Nailing - Berkshire@: Samar uriy L.ta+aa+mua TRINITY; ERD se+oaY;�4 t.rt+utrlJrra • • id r KSOa�Q aa�t ha.irtyd�lrhed.adaPY 6.2.7 Minimum Nailing - Duration®, TruDefinition@ Duration, Duration@ Premium Cool & TruDefinition® Duration® Designer Color Collection: 4 NSA Patt+m Cwaw do d duos &.#O afjS%d &W WWk A�tyy�g d� dam7tmwNY4� r r g tr ��`f7�o411e i�.b w e"Um 6Yi� •ai. �pVLYJ6tl �YOS VAprtqda da 6 NO n:" e°aia�e«nt rtluiiS PHt+re snY74mroavnoa, tyCY,p.aaehN LI+ dYVds � aawdler°fupu. a�.r.m7e funY�A 1 8uagla Haan ion T • 656 Ex{.bmru Nhle 5%rxpwn 5%Pd6.d+6w*" C{Xr.7-pu4d/+XPOWdI* 6.2.8 Minimum Nailing - TruDefinition® Oakridge% OakridgeS: 4 Nall Paton e,9+ftw714daw, 66k^Erpaarue URN& b618 EYpe+ur. Erpatrd�d.G6�8W4 Cams E>yodaandrbb/BpNg Rxtarlor Research and Design, LLC. Certificate orAdthorIZWOH 00503 6 Nall Pawn EMUfiMa oat blows r bbl8"ErpoeUl• Rtb 6619' ie 6motUt6nNsr✓apag C4Vac E>�66/8pnla irvalUati*n Report 037940.02.12-R2 FL10674-R8 Revision 2: 12/19/2012 Page 4 of 6 TRINITY ERa 6.2,9 Minimum Nailing — WeatherGuard(D HP: 6.3 Hip A Ridge Shingles- 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard0 HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Refer to Owens Corning published Information on wind resistance and installation limitations, Including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — BerkshlreO Hip & Ridge and High Ridge: Flfl. 7 v � marnrgwta 1111eChn A Nalls��.. P 4 1 I A I I 1 F I I I I I I I I A i � I VI ti 6goure 6.3.4 Minimum Nailing — Hip & Ridge with Sealant: em - 4 Nails} met them im Shingle12' nd l0kw*rd2�• 1„ rip -12" Felstening SS"IFstl►asYte Distanr�e 12" Exterior Research and Design, LLC. CeWftratle ofAuthoNsatlon #9503 Fig. 2 Top%fi v SMOVIM HaNt NAM T Ynp Lamhrffiad �^ Gtece I i I I �I I I I I I I I Evaluation Report 037940.02.12-R7. EL10674-R8 Revision 2. 12/19/2012 Page 5of6 ... . .. . ...... ..... ,.\. 'l TRINITY' ERD 6.3.5 Minimum Nailing — WeatherGuard@ HP Hip and Ridge_ Fig. C Hip & Ridge Shingle Faalening ToPVkW malls Ilr lffi Illr 2" S' 1' r CROP A 6.3.6 Minimum Nailing - ProEdge Hip & Ridge Shingles: r1nmain" Wind Direction Sai rt W; 4" W &Pftm Facet! .M R@d G#wd Standard •----11•� Fefftening pattwa 12' Bod�nl 7'h IV 7. LABELING. 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in F13C Table IS07.2.7,1 / P-905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. �. MANUFACTURING PLANTS; Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. :LQ. QUALITY ASSURANCE ENTmr: UL LLC— QUA9625 ; (414) 248-6409; kare .buchmann a�ul_com - END OF EVALUATION REPORT - lrxtarlor Research and Design, LLC. Evaluation Report 037440.02.12-R2 Crr6fitate ofAuWrorhWftn 09B03 FL10674-RO Revision 2: 12/19/2012 Page 6 of 6 t:!rlriun A( SbCQ1s Propr:s?Z' ld:zz!ifica!ioi Site Address_ 6904 Sebastian Rood Scoff ownlR=gc 12 :3dS :39E Magi ID: Bh2N Zoning: RS4 0h'V4RT.J-xp:rrrl Ai:uiin=; Owner. Address: ';ales In!al'miEiau Date 12/3012013 7/1112012 3/1612007 212111990 111/1987 3/1/1984 Cririeton H Sheets (TR) Vaiil MihayloV 6773 SE N rbiarrua Way Stuart FL 34996 Print Code 72600 D001 100 Dill 105000 00 No 01 7000 00 MAO 00 .. <ravvj I' 3 pt1rU f�r.S Vim: ExtT ype: Grade: stosyFlght: #u3erigr ,Mro rri B LdRaomS: FullBstlt: 112Barh: %A1C: Special trat"21.,.;110 Tn", lreszl� Type SDSF - SUE DEV 5-F PROPERTY RECORD CARD O 4— / (94 hl'.S1i SjpL't..15SfE;Eit ?:IvL5 is OI11pliauti 1�r9':1l14S {lain L` Ninl ParodID: 1301-613-0311-000-2 Acommi fi'- 3396 Use Type: SF Res Cityfcnty: Saint Lucio County i.r.�;r€ I;r�ccip{iErrr LAKEWOOD PARK -UNIT I1- BLK I.SD LOT 12 (MAP 13112Nj (OR 3591-2929) NbS s511wni 2013 Deed BoolrlPage 2013 Fival: 470W 1VD 3591 / 2929 ASsC�--M'. 47000 Sip 3409/1394 Ag.Crvdit: 0 WD 2788/2494 Exempt: QC 06791 D684 T axabke CV 0529 / 2.722 Taxes: 951.87 +rV 0427 1 0870 8L7I.13il41, EN_N(rRI;.\,jWN - RoalCover. ED - HD Y=1311: D - 0 EtfYrB lt: 0010 - l Story No.Units: 3 Lledric: l HealType: 0 HeatFuol: 100 "%nHeat+ed: YIS Qty. Units Qual. Cor)d. Y 1 i AV AV SA - Aspb Shingle 1989 1989 1 MX - MA)aMWi 1 FHA - ProdHotAir ELEC - Electric 100 l a nrl I n fir rani d ol; YrBlt. No. USeType 2001 1 0100-SF Res Tj)t:% 5--ori. and 1;5rarlil!r Laud Value: 5400 Acres-. I)X Building Values 41600 Finished Area: 15M SgFt RooiStruct: GA- Gable Frame. - Pritn6vall• FS -Frm Stoem SeeWalt: Ptml)1tWall: DW -Drywall AvgHVFI: STD Pmt.Flors. RC - Raised Canc %Sprinkted: 0 Type meamn BI -Front Ft 90 Depth 131