Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDater W .. Fee Due: 0_�_ : Receipt# 54rmit # Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. Fort Pierce, FL 34982 (772)462-1553 SPECIALTY PERMIT APPLICATION ❑ Electrical E Plumhing ❑ HVAC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding Seepage 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: —? QC;-7 L`b)O- 7 4CY 2. Parcel ID Number: Office Use Only Section Township Range Map Page Zoning Land Use Initials 3. Complete Description of Project or Work: 4. Owners Information 5. Contractors Information Name: Ck� ,r (CA�v2 C FL Reg/Cert #: Address: County Cert#: City: U-Ke§tate: Business Name: -Ti (:2�c'� Zip: 3 (4 9 eco Phone: Ql-Igi -Lk39-(((ZPhone-.-) ?z--q l9 -) ax: --)1 Z— e%�5-1 _ ?.�7 q 6. Value of Construction: $ 2300 OWNERS AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction an zoning. aCA�©Y1 L&-)t tlir� the PRINT OWNER OR CONTRACTOR NAME l% S OF OWNER OR CONTRACTOR STATE OF FLORIDA, COUNTY OF C/LIC� ACKNOWLEDGED BEFORE ME THIS —DAY OF rd9i 120J t( , B r/l C�ti'1 Vl/ ! �y' ,✓_J{/ WHO IS PERSONALLY MOWN TO ME OR WHO HAS PRODUCEDFL L Ool tyw L( ENTIFICATIO Poe% JASON HENDRY COMMISSION # EE 058256 G ATURE OF NOTARY TYPE OR PRINT NAME OF OTARY s ; EXPIRES: February 23, 2015 Bonded Thru Budget Notary Services C �fISSIONNU1ViBER� S j0 NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 Revised 04/26/2010 Property Appraiser - St.Lucie County, FL Charlotte C Clark (TR) Record: I of 1 Property Identification Site Address: 7207 MARSH TERR Sec/Town/Range: 22 :36S :39E Map ID: 33/22N Zoning: PUD http://www.paslc.oror/pasle/prc.asp?prclid=332180500240000 PROPERTY RECORD CARD «Prey Next» Spec.Assmnt Taxes Exemptions Permits Home Print Ownership and Mailing Owner: Charlotte C Clark (TR) Address: 7207 Marsh Terr Port St Lucie FL 34986-3232 QUCIE p0G ParcellD: 3321-805-0024-000-0 z 2� Account #: 135101 Use Type: City/Cnty: SF R aint Lucie County Legal Description MARSH LANDING AT THE RESERVE -PHASE TWO- LOT 59 (OR 2260-1342: 3090-1181) Sales Information Assessment 2013 Date Price Code Deed Book/Page 2013 Final: 195600 4/29/2009 100 0130 DE 3090 / 1181 Assessed: 195600 5/11/2005 380000 00 WD 2260 / 1342 Ag.Credit: 0 6/10/2004 320000 00 WD 1992/2526 Exempt: 50000 10/31/2003 304500 00 WD 1835 / 0245 Taxable: 145600 10/31/2002 266700 00 SP 1619 / 2949 Taxes: 3130.18 10/25/2001 225000 02 WD 1452 / 2782 5/28/1996 200000 02 WD 1017 / 2455 BUILDING INFORMATION Exterior Features View: 3100 - Lakefront-SM RoofCover: ExtType: HB - HB YearBlt: Grade: B - B EflYrBlt: StoryHght: 0010 -1 Story No.Units: Interior Features BedRooms: 2 Electric: FullBath: 2 HeatType: 1/2Bath: 1 HeatFuel: %A/C: 0 %Heated: Special Features and Yard Items Type Y/S Qty. Units Qual. Cond. YrBlt. ENC2 - POOL ENC-AVG Y 1 1066 AV AV 2003 PA01 - POOL DK-AVG Y 1 769 AV AV 2003 PHTR - POOL HEATER Y 1 1 AV AV 2002 SWAV - RES POOL AVG Y 1 297 AV AV 2003 DWC - Driv-Concret Y 1 400 AV AV 2002 Total Land and Building Land Value: 49200 Acres: 0.27 Building Value: 146400 Finished Area: 2010 SgFt CS - Conc Shingle RoofStruct: 2002 Frame: 2002 PrimeWall: 1 SecWall: HP - Hip BS - CB Stucco MX - MAXIMUM PrmintWall: DW - Drywall FHA- FrcdHotAir AvgHt/Fl: ELEC - Electric Prm.Flors: CU - Carpet 100 %Sprinkled: 0 Land Information No. Use Type Type Measure Depth 1 0100-SF Res GFI -Front Ft 91.84 134.08 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. 1 of 1 2/18/2014 12:13 PM I/ I INSTALLATION Placement of Heater -Indoor Installation - Indoor installations can be problematic, and for that reason are discouraged. However, if no viable alternative exists, indoor installations may be successfully accomplished provided very exacting cri- teria is addressed. Every indoor installation is unique;, therefore, there are no specific guidelines for this type of installation. If considering an indoor installation, you are strongly urged to contact the AquaCal Engineering department (727) 823-5642 for assistance prior to proceeding. -Outdoor Installation - Service and Operational Clearances: • To operate correctly, heat pumps require large volumes of air moving over the heat collector. allowadequate clearance between the heat pump and walls, fences, shrubs, or other objects. Refer to required clearance drawings below. m Allow five (5) feet of vertical clearance between the top of the heat pump and any roof overhang or other obstruction. This clearance prevents cold discharge air from recirculating back into the heat pump (recirculation will reduce the overall performance of the heat pump). * The access panel requires removal during installation and service. Do not place plumbing, or other items, closer than 30" from the front of the heater. Code. Required Clearances: In addition to the previously stated clearance requirements, follow all applicable local, state, and national requirements relative to spacing from other objects or equipment. Required Installation Clearances .--- -- - - SQ Mom -Ls, 12-INCHES; ALL OTHER, 6-INCHES OVERHANGWITH i it (REAR) GL rr_R I RAIN RLN-OFT MusT s"e DIRECTED AWAY FROM 12- HEAQER- s C'.­e, 1. 5Q Mow-t5, 12-Ir,c-es 1 A-L ONE*, 30" M.`i:N94 'f CL--Afwic?, Flm- ► (REAR) SIDE VIEW (No SCALE) FRONT -REAR -OVERHEAD 30—I 1 f Top VIEW (No SCALE) FR.................. ........... ®�li'-SI®ES-REAR 39 INSTALLATION - PLACEMENT OF HEATER (continued) Irrigation, Rainwater Runoff, and Landscape Features © Place the heat pump away from direct rain runoff from roofs. If roof slope directs runoff into the heater, a gutter or rain shield will be required on the roof edge above the heat pump. ® Relocate or adjust irrigation to avoid water spray onto the heat pump. • Do not locate the heat pump directly adjacent to plants, shrubs, or bushes. Doing so. will prevent proper air circulation into the unit, and may inhibit access to the heater when service is needed. e Consult drawings on previous page (Required Installation Clearances) for proper spacing to other objects. Equipment Mounting Pad Requirements ® The equipment pad shall be constructed of concrete, pressure treated wood, or other code - approved materials. a The equipment pad shall meet all requirements of authorities having code -related jurisdiction. The pad shall be elevated and placed to provide adequate drainage and support to the base of the heat pump. The pad should be essentially level with just enough pitch to drain condensate and any other water away from the heater. A The pad shall extend —in all directions —(at least) 3" beyond the base of the heat pump. o Under no circumstances shall the heater be installed directly onto the earth. Anchoring Heater to Pad Follow all relevant local, state, or national requirements regarding wind load anchoring. When anchoring is required, use AquaCal optional Hurricane Anchoring Kits. -AquaCal anchoring kits satisfy, completely, the very stringent Florida Building Code Section 301.13: Wind Anchoring Requirements. -ContactAquaCal Parts Group (727-823-5642) to obtain the correct anchoring kit for the heater being installed. - Please have the heater model number ready when contacting AquaCal Parts Group. e As necessary, contact the AquaCal Technical Support Group (727-823-5642) for assistance in determining best method of compliance. Failure to heed the following may result in permanent injury or death. Installation made by unqualified persons can result in hazards to the installer and others. The information contained throughout the "Installation" section is intended for use by qualified heat pump installation technicians, familiar with the swimming pool/spa service industry safety standards and methods. Installation to be performed by qualified individuals only. 40 INSTALLATION Electrical Requirements Failure to heed the following may result in permanent injury or death. Installation made by unqualified persons can result.in hazards to the installer and others. The information contained in this Electrical Installation section is intended for use by qualified electrical installation technicians, familiar with electrical service industry safety standards and methods. Electrical installation to be performed by qualified individuals only. General Requirements • Locate the equipment disconnect means within 3-feet of the heater's electrical enclosure, or as close to the heater as possible. Always satisfy applicable codes and standards. • AquaCal heat pumps are designed for copper conductors, only. Never mount disconnect directly to heat pump. • In sizing power wiring, be especially aware of up -sizing requirements necessary due to wiring distances. Always satisfy applicable codes and standards. • Multiple heaters installed at same site generally require special sequencing controls (an "ASC" controller will be required). If yours is a multi -heater installation, contact AquaCal Technical Support Group (727-823-5642) for application assistance. . Electrical installation should be by licensed electrician only. Code -Specific Requirements e The electrical installation must conform to the most current version of the National Electrical Code, NFPA No.70, and all applicable local and state codes. e National Electrical Code, Article 680, Swimming Pools Fountains and Similar Installations, shall apply- o National Electrical Code, Article 440Air-Conditioning and Refrigeration Equipment, shall apply. Connecting External Controllers See document entitled: "Connecting External Controllers to AquaCal Heat Pumps"; this document is shipped with every AquaCal heater. For extra copies, contact AquaCal Customer Support (727-823-5642); request literature piece: "LTP0050." ® For Call -Flex option, reference instructions received with the Call -Flex kit. ® Please contact the AquaCal Technical Support Group (727-823-5642) concerning the application of any external controller, Call -Flex, sequencing control, etc. 44 INSTALLATION Electrical Requirements (continued): Sizing the Electrical Service... Reference the Equipment Data Plate ® All AquaCal heat pumps have two. (2) identical data plates affixed: one can be found outside the unit, on right front corner; the second data plate is located behind the front access panel, on the electrical enclosure cover. 0 Refer to either equipment data plate for unit -specific electrical power supply requirements. © Based on data plate information, size wiring, wiring devices, and over -current protection per applicable codes and standards. • Refer to drawing below for data plate items specific to electrical installation requirements. On the installed heater data plate, the areas depicted below, numbered 1-11, will contain the information required to size the electrical service and over -current protection. ELECTRICAL PORTION of DATA PLATE MINIMUM CIRCUIT AMPACITY: #1 ELEC. SERVICE: VOLTS 1 #2 SUITABLE FOR OUTSIDE USE IPX4 m MAXIMUM TIME DELAY FUSE OR HACR BREAKER: COMPRESSOR.- VOLTd #6 RLA #7 FAN MOTOR: VOLTS 1 #9 HP 1 #10 REFRIGERANT: Factory charged =ONLY oz/Kg Tested to High side / Q Low side MADE IN THE U.S.A. A Word Concerning Ground -Fault Protection o The National Electrical Code (NEC) contains no standards requiring Ground -Fault Interruption protection (via GFl Circuit Breaker or otherwise) of "Fixed" or "Stationary" equipment, under ' article 680: Swimming Pools. Fountain, & Similar Installations, or Article 440: Air -Conditioning & Refrigeration Equipment. © The preceding standards govern the installation of AquaCal (and other manufacturers') heat pumps. AquaCal heat pumps are, designed, and safety tested by a certified laboratory, to be installed under applicable standards detailed within the NEC. AquaCal does not recommend the use of ground fault protective devices in conjunction with heat pumps. Service calls, found to be due to " nuisance" tripping of ground fault devices, are not covered under the AquaCal factory warranty. 45