Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDA FEES DUir,: St. Lucie County Building & Zoning ® 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 SC B Tel.772-462-1553 V EFJ �- - - APPLICATION FOR ROOF PERMIT sr• Lucie n SEE EVERSE SIDE FOR INSTRUCTIONS COUnty 1. Location/Site Address: (�70 `!' l Q/l/rc,�,, O 2. Parcel ID Number: 13n l- (D l I -=LIJ - cod - Q- Office Use Section Township Range Ma Pa a ZoningLand Use Initials Only 3. Description of Project or Work4ctivi 4. Total Roof Area (square feet): 6. Type of Roof: [ t,]1'iberglass Shingle 5. Roof"Pitch: [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [✓]Modified Bitumen [ ] Other [ v] N.O.A. or Florida - Product Approval required for all types of Roofing Material (2 Sets) [ ] All. Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.944 will be required. 7. Owner Information 8. Contractor Information Name: c� Address: 1 `70 q P-Q-Lsnsa - o City: �C- - PLLJ-Q.e State: f:F-- Zip: 94`lam Phone: `n a - y 00. 13(0L/ 9. Value of Construction: $ 3.4 ( D . Note Dry -in and Final Inspection Required m Additional inspection may be required per Product Approval FL Reg/Cert #: • CSC ( 3 0 (Q, t -71 County Cert #: Business Name: 4LA Fees Due: Receipt #: CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that -all work will be done incompliance wigplicable laws regal ' g c stru and zoning. i PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIERIOWNER STATE OF FLORIDA, COUNTY OF cS L L ACKNOWLEDGED BEFORE ME THIS �_ DAY OF 20iSA� BY _ ` ,L """ J—) WHO IS PERSONALLY KNOWN TOME OR HAS PRODUCED AS IDE NMI AWJOP�F— SHARON KAUFMAN SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY MY C SSION #FF052943 COMMISSION NUMBER {407)398.0153 EXPIRES September 10. 2011 NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. 3SE?H E. SMITH.::LERK 0, THE C1:-7 .sSl'>, A!NT L� C E 0UN T Y _4U' :E OF COMMENCEMENT The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. ejjal Descriptions f Property: (and street address if available): aak-0f tYfir /' �1-lL,���-,BI,�/!/ /,o��/s- (�709 %,.z.nASq=141A-P— FRI Az4-c ,�(, 3.ewf,57- General description of improvement: &-AVI -2 .L[/� Owner information or Lessee information if the Lessee contracted for the improvement: Name 9- -Qc-, z Aweat Interest in property: 'JWhGZ Name and address of fee simple titleholder (if different from Owner listed above): Contractor's Name: Contractor Address: Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ Name and address: Lender Name: _ Lender's address: one Number: Phone Number: one number: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1) (a)7., Florida Statutes: Name: Phone Number: Address: In addition to himself or herself, Owner designates of Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the.facts stated therein are true to the best of rn"nowledee and belief. of Owner or Lessee, or Owner's or Lessee's Authorized Officer/Director/Partner/Manager (Signatory's Title/Office) 'Pp. SHARON KAUFMAN c MY COMMISSION #FF052943 •',�EOFFoe.;' EXPIRES September 10. 2017 The foregoing instrument was acknowledged before me this19 day of115LZA- , 20/ Cf (407) 398.0153 FloridallotaryService.com By la/l0� �L.Y1�CJ( as for Name of Person Type of authority e.g. officer, trustee) Party on behalf of whom instrument was executed c-Z (-lrlti Personally known_ or produced Identification (Signature of Notary Public - State of Florida) (Print, Type, or Stamp Commissioned Name of Notary Public) Type of Identification produced I�L 0212712014 11 :0 1 All Area Roofing r . _+FAk)772 464 6600 P.0011001 Planning & Development Services Building & Code RegWation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax. 77Z-462-6443 R00F'1NSPgCTJ0N AFFIDAVIT Re: Permit #. �(!/ - 0� 5- I, icy licensed as a(n)Contractor*/Engineer/Architect (Please print name ci cle license type)F5468 Building Inspector *General, 9uilding, Residential or Roofing Contractor or any Individual certified under468 F.S. to make such an inspection. On or about 02 ate I did personally inspect the roof deck nailine work at: Pc-.2.lCp7l ob site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553,844 F.S,) r Signature and Seal license N STATE OF FLORID COUNTYOF Sworn to and subscribed before me this day of 20 by t-I -{ Who is personally known to me or who has produced ka-el c.5 as Identification. Notary Public, State of FI rich Signature of Notary:r& � c Commission Number: ----...-_-_-_- En 01/19/2011 53 SHARON KAUFMAN My COMMISSION ##5F052943 EXPIRES September 10, 2017 ENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fat: (866) 78 4-8550 wwii floridaenginecringancltesting.com 250 S.W. 131h Avenue Pompano Beach, FL 33069 DATE: 2/13/14 JOB ORDER #: 14-562 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 Fort Pierce, Florida 34982 PROJECT: Regina Byrd Residence Flat Wood Non -Insulated Roof Deck ADDRESS: 6709 Penny Lane Fort Pierce, Florida FBC 2010/ASCE 7-10 DESIGN PRESSURE CALCULATIONS Project Information: Height = 8' Exposure: C Basic/Ultimate Wind Speed: Vi1t=170 mph Length = 24' Category: II Nominal Wind Speed: Vasa=Vult*0.6 Width = 15' Slope: < 7° (asd = allowable strength design) Parapet Wall: N/A Residential KZ = 0.85, Kzt = 1.0, Kd = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*KZK tKdV2 Velocity Pressure (ult): q=0.00256(0.85)(1.0)(0.85)(170)2] = 53.45 psf Velocity Pressure (asd): q=0.00256(0.85)(1.0)(0.85)(170*0.6)2] = 32.07 psf Width of Pressure Coefficient: 0.l(15') = 1.5' 0.4(8') = 3.2' } use: 3'0" Effective Wind Area: <10ft2 For parapet height three feet (3') or larger, zone three (3) shall b as zone two (2). External Pressure Coefficient: Internal Pres"s Efficient: 1) GCP1 = -1.0 1) GCP; _ 2) GCP2 = -1.8 3) GCP3 = -2.8 0- Quamyt A 4,s assurance ��3 `e� Page 2, 2/13/14, Job Orde",_ _4-562 , All Area Rooting - Regina Byrd Residence Flat Wood Non -Insulated Roof Deck 6709 Penny Lane; Fort Pierce, FL: Design Pressures Based on Vasd: 1) Field P1 = 32.07*[(-1.0) — (0.18)] = -37.8 psf 2) Perimeter P2 = 32.07*[(-1.8) — (0.18)] = -63.5 psf 3) Corners P3 = 32.07*[(-2.8) — (0.18)] = -95.6 psf Attachment Requirements Per RAS-117: Based on the requirements of N.O.A. #13-0204.03, System Type E(3), pg 28 of 32, with a maximum design pressure of-52.5psf; the following are our recommended fastening patterns to attach the proposed base sheet to the wood (non -insulated) deck utilizing approved 11 ga. annular ring shank nails and approved tin caps: Field: 8" o.c. @ 4" laps and 3 staggered rows 8" o.c. Perimeter: 8" o.c. @ 4" laps and 4 staggered rows 8" o.c. Corners: 6" o.c. @ 4" laps and 5 staggered rows 6" o.c. Notes: Corners and perimeter area dimension shall not be less than a = TO" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2010 Edition. Wind load calculations based on ASCE 7-10, FBC 2010 and information provided by client. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely, ` Reza 7avid�n, P.E. Florida Engineering & Testing, Inc. Florida Reg. No. 60223 Certificate of Authorization No. 6923 moo,wy.- ;;`s" DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA CertainTeed Corporation 1400 Union Meeting Road, P.O. Box 1100 Blue Bell, PA 19422-0761 M[AMI-DADE CO LINTY PRODUCT CONTROL SECTION I1805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidade.eov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials_ The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product, Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-pade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miam ade County, Florida, and followed by the expiration date may be displayed in advertising literat t> I. I ny portion of the NOA 'is displayed, then it shall be done to its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by t aannuf cturer or its distributors and shall be available for inspection at the job site at the request o �ti ng Official. This NOA renews and revises NOA No. 08-0410.09 and consists of pages 1 throu h 32. The submitted documentation was reviewed by Jorge L. Acebo. a� MIAMI•DADE COUNTY �11111= Expii Apl ROOFING SYSTEM APPROVAL Category Roofing Sub -Category: Modified Bitumen Material: APP/SBS Deck Type, Wood Maximum Design Pressure: -60 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description All Weather/Empire Base 36" x 65' 10"; ASTM D 4601 Asphalt coated, fiberglass Sheet Roll weight: 86 lbs. .Type II reinforced base sheet. (2 squares) UL Type 15 Flex-I-GlasTM Base Sheet 36" x 98'9'; Roll ASTM D 4601, Modified Bitumen coated weight: 90 lbs. Type II fiberglass base sheet. (3 squares) UL Type G2 Flex-I-GlasTM FR Base 39 3/8" x 50; Roll ASTM D 6163, Modified Bitumen coated Sheet weight: 90 tbs. Grade S, Type I fiberglass base sheet. (1.5 squares) Flintglas® Ply Sheet Type 36" x 164'7"; Roll ASTM D 2178 Fiberglass, asphalt impregnated ply IV or VI weight: 40/55 lbs. Type IV or VI sheet. (5 squares) UL Type G 1 Flintlastic STA 39 3/8" x 33; Roll ASTM D 6222, Smooth surfaced APP Modified STA Plus 5.0 weight: 90 lbs. Grade S, Type II Bitumen membrane with non - (I square) woven polyester mat reinforcement for torch application. Flintlastic GTA, GTA-FR 39 3/8" x 33' 3"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G, Type II Bitumen membrane with non - (I square,) woven polyester mat reinforcement for torch application. Flintlastic GMS, 39 3/8" x 34' 2"; Roll ASTM D 6164, Granule surfaced SBS Modified GMS Premium weight: 100/105 lbs. Grade G, Type II Bitumen membrane with non - (I square) woven polyester mat reinforcement for mop application. Flintlastic FR, 39 3/8" x 34' 2"; Roll ASTM D 6164, Fire resistant, granule surfaced FR-P Premium weight: 105 lbs. Grade G, Type I SBS Modified Bitumen Membrane (1 square) with non -woven polyester mat reinforcement for mop application. Flintlastic FR Cap Sheet 39 3/8" x 34' 2"; Roll ASTM D 6163, Fire resistant, granule surfaced weight: 90 lbs. Grade G, Type I SBS Modified Bitumen membrane (I square) with fiberglass mat reinforcement for mop applications. Flintlastic FR Cap T 39-3/8" x 34'2"; Roll ASTM D6163 Granule surfaced SBS Modified weight: 81 lbs. Bitumen membrane with fiberglass (1 square) mat reinforcement for torch application. NOA No.: 13-0204.03 MIAMI•DADECOUNTY ... 6 Expiration Date: 06/19/14 Approval Date: 05/30/13 Page 2 of 32 Test Product Product Dimensions' Specification Description Flintlastic FR Base T 3.9-3/8" x 33'; Roll ASTM D6163 Modified Bitumen, coated Weight: 81tbs. fiberglass base sheet for torch (LO squares) application. Flintlastic FR Cap CoolStar 39 3/g" x 34' 2"; Roll ASTM D 6163 Fire resistant, granule surfaced weight: 90 lbs. SBS Modified Bitumen membrane (1 square) with fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. Flintlastic FR Cap T 39 3/8" x 34' 2"; Roll ASTM D 6163 Fire resistant, granule surfaced CoolStar weight: 90 lbs. SBS Modified Bitumen membrane (1 square) with fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. Flintlastic GTA, GTA-FR 39 3/8" x 33' 3"; Roll ASTM D 6222 Granule surfaced APP Modified CoolStar weight: 1-05 lbs. Bitumen membrane with non - (I square) woven polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. Flintlastic GMS/GMS 39 3/g" x 34' 2"; Roll . ASTM D 6164 Granule surfaced SBS Modified Premium CoolStar weight: 100/105 lbs. Bitumen membrane with non - square) woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic FR-P/FR-P 39 3/8" x 34' 2"; Roll ASTM D 6164 Fire resistant, granule surfaced Premium CoolStar weight: 105 lbs., SBS Modified Bitumen Membrane (1 square) with non -woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Covered with reflective CoolStar Coating. Ultra Poly SMS 36" x 64'4" ASTM D 6164, Smooth surfaced SBS Modified (2 squares) Grade S, Type I Bitumen Membrane with non- woven polyester mat reinforcement for mop applications. GlasBaseTm Base Sheet 36" x 98'9"; Roll ASTM D 4601 Asphalt coated, fiberglass base weight: 69 lbs. UL Type G2 sheet. (3 squares) PolySMS Base Sheet 39 3/8" x 64' 4"; Roll ASTM D 4601, Modified Bitumen coated polyester weight: 90 lbs. Grade S, Type II base sheet. (2 squares) UL Type G2 Yosemite® Buffer Base 36" x 32' 10"; Roll ASTM D 3909 Mineral Surfaced fiberglass Sheet weight: 90 lbs. ASTM D 4897 reinforced buffer sheet. (1 square) UL Type 30 Black DiamondTM Base 36" x 687'; Roll ASTM D 1970 Self -adhering fiberglass reinforced Sheet weight: 78 lbs. modified bitumen base sheet (2 squares) NOA No.: 13-0204.03 MIAMMADECOUNTY Expiration Date: 06/1.9/14 Approval Date: 05/30/t3 Page 3 of 32 APPROVED INSULATIONS: Product Name FlintBoard ISO ACFoam -[I High Density Wood Fiberboard Perlite Insulation DensDeck, DensDeck Prime H-Shield ENRGY 3, ENRGY 3 25 PSI Multi -Max FA-3 TABLE2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Wood fiber insulation board Perlite insulation board Water resistant gypsum board Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Manufacturer (With Current NOA) CertainTeed Corporation Atlas Roofing Corporation Generic Generic Georgia Pacific Gypsum LLC Hunter Panels LLC Johns Manville Corp. RMax Operating, LLC APPROVED FASTENERS: TABLE3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Dekfast 12 & 14 Insulation fastener SFS [ntec, Inc. Fastener 2. Dekfast Galvalume Galvalume AZ50 steel plate 2 7/8" x 3 -A" SFS Intec, Inc. Steel Hex Plate 3. OMG #12 & #14 Insulation fastener OMG, Inc. Roofgrip Fasteners 4. OMG 3 in. Round 3" round galvalume AZ50 3" round OMG, Inc. Metal Plates steel plate 5. Trufast #12 DP Insulation fastener for wood Altenloh, Brinck & Co. Fastener and steel decks U.S., Inc. 6. Trufast 3" Metal Galvalume steel plate 3" round Altenloh, Brinck & Co. Insulation Plate U.S., Inc. 7. Trufast 3" TL Galvalume steel plate 3" round Altenloh, Brinck & Co. Insulation Plate U.S., Inc. 8. Dekfast 15 HS Coated, carbon steel Various SFS Intec, Inc. fastener 9. Trufast #15 EHD Coated, carbon steel screw various Altenloh, Brinck & Co. Fastener U.S., Inc. 10. Trufast # 14 HD Coated, carbon steel screw various Altenloh, Brinck & Co. Fastener U.S., Inc. . 11. Trufast 2" Metal Seam Galvalume steel stress plate 2" round Altenloh, Brinck & Co. Plates U.S., Inc. MIAMI•DAD=COUNTY= NOA No.: 13-0204.03 Expiration Date: 06/19/14 Approval Date: 05/30/13 Page 4 of32 EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date Factory Mutual Research Corp. FMRC 4470 J.1. 3Y8A LAM 03/23/96 Underwriters Laboratories, Inc. UL 790 R11656 01/11/13 United States Testing Company ASTM D 5147 97457-4 06/03/88 ASTM D 5147 97-457-2R 12/02/87 Momentum Technologies, Inc. ASTM D 4601 AX31G81) 09/05/08 ASTM D6164 AX3lG8F 06/05/09 ASTM D6222 AX31G8G 06/OS/09 ASTM D 3909/ D 4897 AX31G8C 09/OS/08 TrinityjERD TAS 114(J) 93507.08.99-1 04/18/01 TAS 114(J) 93514.02LAB 11/11/02 TAS 117 (B) 3503.10.06 10/10/06 TAS 117 (B) 06490.04.07-R1 06/27/07 TAS 114 (H) Letter 04/05/06 TAS 114 3533.01.06 01/06/06 TAS 114 3521.07.04 07/29/04 TAS 117 (B)/ ASTM D 6862 C8500SC.11.07 11/30/07 TAS 114 C8370.08.08 08/19/08 ASTM Physical Properties C10080.09.08-R4 03/25/10 ASTM 136164/134798 C31410.01.11-2 01/10/l 1 ASTM D4601 C40050.09.12-1 09/28/12 ASTM D1970 C40050.09.12-2 09/28/12 ASTM D5147/134798 C31410.10.10-R1 11/01/12 ASTM D5147/D4798 C31410.01.11-1-R1 11/01/12 PRI Construction Materials ASTM D6163 CTC-032-02-01 01/22/08 Technologies LLC ASTM D6163 CTC-066-02-01 08/09/11 ASTM D6164 CTC-068-02-01 08/09/11 ASTM D6222 CTC-070-02-01 08/09/11 ASTM 136164/134798 CTC-093-02-01 08/09/11 ASTM D2178 CTC-122-02-01 03/13/12 ASTM D2178 CTC-123-02-01 03/13/12 ASTM D4601 CTC-127-02-01 03/13/12 ASTM D6163 CTC-128-02-01 06/11/12 ASTM D6163 CTC-129-02-01 06/11/12 ASTM D6164 CTC-132-02-01 06/11/12 NOA No.: 13-0204.03 MIAMI•DADECOUNTY Expiration Date: 06/19/14 Approval Date: 05/30/13 Page 5 of 32 Membrane Type: APP MODIFIED Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System Type E(3): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet, Glas Base or Flintglas Premium Ply Sheet (Type VI) mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: (Optional ) One ply of All Weather/Empire Base Sheet, Ultra Poly SMS, Glas Base, Flex -I Glas Base, Flex-] Glas FR Base or Poly SMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet self -adhered or Flintlastic STA torch adhered. Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or GTA-FR CoolStar torch adhered to base/ply sheet. Surfacing: (Optional) Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install one of the following: 1. 400-lb./sq. gravel or 300-lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Karnak (#97 AF) Fibrated Aluminum Roof Coating, FlintCoat A-150, APOC #212 Fibrated Aluminum Roof Coating at an application rate of 1 '/2 gal. /sq. Maximum Design Pressure: -52.5 psf (See General Limitation 97) NOA No.: 13-0204.03 Expiration Date: 06/19/14 Approval Date: 05/30/13 Page 28 of 32 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved, Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. [f no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 tbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psE 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. [f the fastener value, as field-tested, are below 275 IbE insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMMADE COUNTY NOA No.: 13-0204.03 Expiration Date: 06/19/14 Approval Date: 05/30/13 Page 32 of 32 1 MIAMI-DiADE ® MIAMI-DADE COUNTY PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 r (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miainidRde.gov/building/ Tamko Building Products, Inc. 220 West Fourth Street Joplin, MO 64802 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade Cdunty) reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TAMKO Roof Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade C lorida, and followed by the expiration date may be displayed in advertising literature. If any portion of t e A - displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manu r its distributors and shall be available for inspection at the job site at the request of the Building Offici This revises NOA # 10-0831.05 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA 223.11 Expiration ate: /01/15 Approval 2/11 f4 ROOFING ASSEMBLY APPROVAL Catezory Roofing Sub-Cateeory: Asphalt Shingles Materials Laminate Deck Type: Wood SCOPE This approves Tamko Heritage 30, Heritage, Heritage 50, Heritage Premium, Heritage XL, and Heritage Woodgate Asphalt Shingles, manufactured by Tamko Building Products, Inc, as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Specifications Heritage 30 and Heritage 13 %4 " x 39 3/s" TAS 110 Heritage XL and Heritage 13 '/4 " x 39 3/g" TAS 110 Woodgate Heritage 50 and Heritage 13 '/a " x 39 3/9" TAS 110 Premium MANUFACTURING LOCATION 1. Dallas, TX 2. Tuscaloosa, AL EVIDENCE SUBMITTED Product Description A heavy weight, dimensional asphalt shingle. A heavy weight dimensional asphalt shingle. A heavy weight, dimensional asphalt shingle. Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories, Inc TAS 107 04CA44252 02/25/05 ASTM D3462 02NK33813 09/23/02 ASTM D3462 03CA14536 01/15/04 PRI Asphalt Technologies, Inc. TAS 100 TAP-129-02-01 05/23/05 TAS 100 TAP-130-02-01 05/23/05 TAS 100 TAP-131-02-01 05/23/05 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. NOA No.: 11-0223.11 Mu4taanaae COUNT r Expiration Date: 12/01/15 Approval Date: 05/12/11 Page 2 of 4 INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail'B', attached. LABELING 1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved". BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 11-0223.11 Expiration Date: 12/01/15 Approval Date: 05/12/11 Page 3 of 4 DETAIL A HERITAGE 30, HERITAGE, HERITAGE XL, HERITAGE WOODGATE, HERITAGE56, AND HERITAGE PREMIUM All dimensions are in inches. 5TH COURSE 4TH COURSE 04' 3RD COURSE 2ND COURSE 23 1ST COURSE 29 Full DETAIL B HERITAGE 30, HERITAGE, HERITAGE XL, HERITAGE WOODGATE, HERITAGE50, AND HERITAGE PREMIUM 13-1/4" X 39-3/8" LAMINATED SHINGLE All dimensions are in inches I0 39-3/8" `I ----------------j-------------------------.-------------------------------------- 6-1/8" END OF THIS ACCEPTANCE MIAM!-DADE COUNTY 13-1/4" 5-5/8" Exposure NOA No.: 11-0223.11 Expiration Date: 12/01/15 Approval Date: 05/12/11 Page 4 of 4