Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: FEES DUE: RECEIPT Permit Planning & Development Services Department Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel. 772-462-1553 APPLICATION FOR ROOF PERMIT SEE REVERSE SIDE FOR INSTRUCTIONS 1. Location/Site Address: 866 Nettles By 2. Parcel ID Number: 4502-501-1052-000-7 sc St. � UCie county Office Use Section Township Range Map Page I Zoni La d Use Ini Only 3. Description of Project or Work Activity: Re -roof 12 squares of asphalt shingles QTt5-uZ-i EE= ) 4. Total Roof Area (square feet): `aCL 5. Roof Pitch: 3/12 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [X] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other [ ] Product Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Informatiion 8. Contractor Informatiion Name: Renaud and Monique Paris FL Reg/Cert #: CCC058327 Address: 866 Nettles By County Cert #: City: Jensen Beach State: FL Zip: 34957 Phone: (772) 229 - 8967 9. Value of Construction: $ 5464.00 Business Name: The Home Depot At Home Services Cell Phone: "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all e infotmation contained in this aprtiektion is correct and that all work will be done in compli nce with ail applicable !K�a g ons ruction and zoning. Quinn Roberts PRINT QUALIFIERS/OWNERS NAME SIGNATURE // U FI STATE OF FLORIDA, COUNTY OF IR. l� ACKNOWLEDGED BEFORE ME THIS 13 DAY OF 201 , BY Quinn Roberts _ WHO IS PE S Y TO ME OR HAS PRODUCED AS IDENTIFICATION it,,�(� _ D AMBER FLENKER iii U(�� F-Len �r S" NOTARY PUBLIC SIGNA NOTAR TYPE OR PRINT NAME OF NOTARY (seal) g� STATE OF FLORIDA a]-rj(�R� Comm#EE215692 COMMISSION NUMBER Expires 7/11/2016 NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # I� Quinn Roberts licensed as a( Contractor Engineer/Architect (Please print name & circle license type) *FS468 ui ing Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about , I did personally inspect the roof deck naili (Date) work at: 866 Nettles Av. Jensen Beach, FL 34957 (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) CCC058327 License # STATE OF FLORIDA DA COUNTY OF !�ke- Sworn to and subscriibnbed-- befor � me this day of 20 by (,tt`/I^ I-4D-. Who is personally known to me or who has produced as identificat' n. Notary Public, State of Flo Signature of Notary: Commission Number: V (Seal) En 01/19/2011 AMBER FLENKER NOTARY PUBLIC s -STATE OF FLORIDA 'W-7.Comm# EB295692 Expires7/11/2016 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 3927047 OR BC, ,�1605 PAGE 2332, Recorded 02/20/2014,' ,01:29 PM AFI'Elt RECORDING - RETURN TO: PERMIT NUMBER: _-, 7 3 -3/ ci2 NOTICE OF COMMENCEMENT The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. I. DESCRIPTION O`FPROPERTY (Legal description of the property & street address, if available) TAX FOLIO NO.: NSo1.-Sot-to52_Goo-�( SUBDIVISION I1��5.LN �$�dnd, ni-�1 fT 0 BLOCK TRACT LOT SLDG UNIT' &&i AJeA�41,, Wyfit. jen5e r. &a&. 51. _3 W16-7 2. GENERAL llESCRIPf10N OF IF rC'('oo� J. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: a. Name and address: Z "dtLA RQ-J'}-��(O�' Ne-�fIYSV� 3�5e,. 5, 3 �/ �/ b. Intetestun property' — c Name and address of fee simple titleholder (if different from Owner listed above): 4. a. CONTRACTOR'S NAME: I I• -0 6r^e— Cnnhacior's address: i%4 ee(lPt i. SURETV lit applicable. a copy critic payment bund its anuchedl. x Namc mat address b. Phone number C. Amount of bond: b. Phone number f-q c3, - - L,[. 6. it. LENDER'S NAME: Lender's address b. Phone number 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1) (a) 7., Florida Statutes: a Name and address b I'homse numbers of designated persons: 8. a. In addition to himself, or.herself, Owner designates °f to receive a copy ofthe Lienor's Notice as provided in Section 713.13 (1) (b), Florida Statutes. b. 1'I1onc number of person or entity designated by Owner. 9. Expiration date of notice of commencement (the expiration date may not be before the completion of construction and final payment to the contractor, but will be I year from the date of recording unless a different date is specified): 20 Under pen f perjury, I declare at I have read the foregoing notice of commencement and that the facts stated therein are true to the bes nowledge d b ' n v� �2/1 akd Yar►s (Signature of Owner or Lessee, or Owner's or Lessee's (Print Name and Provide Signatory's Title/Office) Authorized Officer/Director/Partner/Manager) State of_V2�/v N I' County of '/" , )'tic furegoing instrument was acknowledged before me this day of r. / 20 �trtn as t— �a by (type of authority,...e.g. officer, trustee, attorney in fact) �r Tr OF � �-C�� QA for ���eofperson) �: L UCp E- 0004TY (name of party on behalf of whom instrument was executed) TNI810ToGINTIFYT�.',�'�"'1413+18)' 1lyKnown or Produced ldeutiflcation ZTypeofldentificalionProduced'4 �`o�r�ktL'�r�trP.✓Y4-1_eF/�Sf TR Ut AP41 �D f'OPY H !� I I i OF THE STEPHEN C. BLEHL p-�i,. i MY COMMtSs10N/l20lll6fi (gig atureofNotaryPublle) � N P' ..r.a,. -' j�. 6i EnYtRFB:rtwe24,101{ (Print, Type, or Stamp Commissioned Name of Notary Public) Date Appt: Job # 7336992 Sales Contact: Paris 866 Nettles Blvd Length Diagram Field Inspector: 7 7 Jensen Beach, FL 34957-3368 N S Note: This diagram contains segment lengths (rounded to the nearest whole numbers) over 5 feet. In some cases, segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9) ROOFING SPECIFICATION SHEET DESCRIPTION OF WORK (Cqp)? orPSG) Customer Name: Renuaud &monique Paris Branch Name: Miami Sales Consultant: Stephen Blehl Hurricane Mitigation = No APS Timberline Ultra HD Lifetime Barkwood Number of Squares (excluding Low Slope) = 11.5 Number of Flat Roof Squares = 0 Misc Rigid Ridge Vent = Yes Linear Ft Ridge Vent to be Installed = 40 Rigid Ridge Vent - Color = Black Off Ridge Vent = No Replace Fascia = No Hurricane Mitigation Inspection = No Section 1 S1 Type = Gable S1 Length - Linear Feet =12 S1 Width - Linear Feet = 6 S1 Pitch = 3/12 S1 Number of Valleys = 0 S1 - Removal - Number of Layers = 1 S1 - Removal Type - Layer 1 = Asphalt S1 Additional Stories = No Section 3 S3 Type = Hip S3 Length - Linear Feet = 10 S3 Width - Linear Feet = 2 Date: 2/5/2014 Job #: Material Removal: See Sections for Material Removal Roof Material = Composition Shingles Number of Sections = 3 Flashing Linear Ft of Drip Edge to be Installed = 147 Color of Drip Edge to be Installed = White Section 2 S2 Type = Gable S2 Length - Linear Feet = 38 S2 Width - Linear Feet = 25 S2 Pitch = 3/12 S2 Number of Valleys = 0 S2 - Removal - Number of Layers = 1 S2 - Removal Type - Layer 1 = Asphalt S2 Additional Stories = No Consultant: Stephen Bfeht Page 1 of 4 Job A: Florida Building Code Online- - ` -� Page 1,of 2 riwildia Clkpartme d BCIS Home I Log In ( user Registration Hot Topics j Submit Surcharge ( Stats & Facts I Publications FBC Staff ! BCIS Site Map Links Search 3usines Professi nal =, } � Product Approval ;' „' , USER: Public User Regulation ENO Product Approval Menu > Product or Application Search > Application List > Application Detail ® FL # FL10124-R10 Application Type Revision Code Version 2010 Application Status Approved Comments Archived ( 1 Product Manufacturer GAF Address/Phone/Email 1361 Alps Road Wayne, NJ 07470 (973) 872-4421 Iindareith@trinityerd.com Authorized Signature Beth McSorley Iindareith@trinityerd.com Technical Representative Beth McSorley Address/Phone/Email 1361 Alps Road - Bldg 11-1 Wayne, NJ 07470 (973) 872-4421 BMcSorley@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer [6 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Robert Nieminen PE-59166 UL LLC 05/03/2014 John W. Knezevich, PE L Validation Checklist - Hardcopy Received FL10124 R10 COI Trinity ERD CI - Nieminen - 2013.odf Standard Year ASTM D3161 (Class F) 2006 ASTM D3462 2007 ASTM D7158 (Class H) 2007 TAS 107 1995 http://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZ... 8/23/2013 Florida Building Code Online Page 2 of 2 Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method i Option D 06/21/2013 06/24/2013 07/01/2013 08/23/2013 ......... ..... _................................... --................................. _............... _.... _... ................... _._......... ------..................... .... ,..... _.._...... _............................... _...... __._..... _....................... Summary of Products Model, Number or Name Description L10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated, 5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10124 R10 II er062113FINAL GAF Asphalt Shingles FL10124-R10.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10124 R10 AE er062113FINAL GAF Asphalt Shingles FL10124-R10.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 1940 North Monroe Street. Tallahassee Fl, 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coovriaht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, emall addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: L eG�eik M fiEr.`.til'{tYb6 f'rlt It„4' http://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZ... 8/23/2013 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 oTmNRY ERD 353 CHRISTIA OXFORD, CT UNIT 06478 PHONE. (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT GAF Evaluation Report 01506.01.08-R12 1361 Alps Road, Building 7-3 FL10124-R10 Wayne, NJ 07470 Date of Issuance: 01 /03/2008 Revision 12: 06/21 /2013 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityjERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. r Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 06/21/2013 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTI F [CATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. \.t TRINIT(IERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entity Examination Reference Date GAF (PDM 1915) Letter of Equivalency Seal -A -Ridge Impact Resistant IR 01/13/2012 PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 01NK06632 02/02/2001 UL(TST 1740) ASTM D3161, TAS 107 01NK9226 05/21/2001 UL(TST 1740) ASTM D3161 OINK37122 12/18/2001 UL(TST 1740) ASTM D3462 01NK37122 12/19/2001 UL(TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161, TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 UL(TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161, D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161, D3462 06CAlBO74 06/16/2006 UL(TST 1740) ASTM D3161, D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM 'D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161, D3462 07CA31742 11/08/2007 UL (TST 1740) ASTM D3161, D7158, D3462 OBCA06100 03/13/2008 UL(TST 1740) ASTM D3161, D3462 07CA55908 04/01/2008 UL(TST 1740) ASTM D3161, D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161, D3462 09CA06856 05/15/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09NK06647 08/01/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009 UL (TST 1740) ASTM D3161, D7158, D3462 10CA35554 03/05/2010 UL (TST 1740) ASTM D3161, D7158, D3462 10CA13686 05/15/2010 UL(TST 1740) ASTM D3462 10CA07264 05/27/2010 UL (TST 1740) ASTM D3462 10CA11953 10/29/2010 UL(TST 1740) ASTM D3161, D7158, D3462 1ONK11951 10/30/2010 UL(TST 1740) ASTM D3161, D7158, D3462 1ONK12070 11/04/2010 UL(TST 1740) ASTM D3161, D7158, D3462 OBCA06100 01/30/2010 UL(TST 1740) ASTM D3161, D7158, D3462 10CA53934 03/31/2011 UL(TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011 UL(TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011 UL (TST 1740) ASTM D3161, D7158, D3462 '11CA48408 12/08/2011 Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R12 Certificate of Authorization #9503 FL10124-R10 Revision 12: 06/21 /2013 Page 2 of 4 Entity UL (TST 1740) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (QUA 9625) 4. PRODUCT DESCRIPTION: Examination ASTM D3161, D7158, D3462 ASTM D3462 ASTM D3161, D7158, D3462 ASTM D3161 Quality Control _ Reference Date 11CA48725 12/09/2011 12CA34891 10/12/2012 12CA58151 02/15/2013 13CA32332 06/18/2013 Inspection Report, File No. R21 05/03/2013 4.1 Marquis WeatherMax, Royal Sovereign and Sentinel are a fiberglass reinforced, 3-tab asphalt roof shingles. 4.2 Camelot, Camelot II, Capstone, Country Mansion, Country Mansion II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Slate, Grand Slate II, Monaco, Sienna, Timberline American Harvest, Timberline ArmorShield II, Timberline Natural Shadow, Timberline Natural Shadow Arctic White, Timberline HD, Timberline Cool Series, Timberline Ultra HD and Woodland are fiberglass reinforced, laminated asphalt roof shingles. 4.3 Slateline is a fiberglass reinforced, 5-tab asphalt roof shingle. 4.4 Seal -A -Ridge, Seal -A -Ridge Armorshield, Seal -A -Ridge IR and Timbertex Hip and Ridge are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.5 Pro -Start Starter Strip Shingles and WeatherBlocker Starter Strip Shingles are a starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 All GAF shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vaed = 150 mph (V„ It = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.2 All GAF hip & ridge shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vaed = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R12 Certificate of Authorization #9503 , FL10124-R10 Revision 12: 06/21 /2013 Page 3 of 4 TRINITY ERD 6.2 Starter Shingles: 6.2.1 Installation of Pro -Start Starter Strip Shingles and WeatherBlocker Starter Strip Shingles shall comply with the manufacturer's current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Slate, Grand Slate II, Country Mansion II and Woodland require minimum five (5) nails per shingle. ➢ Slateline requires minimum six (6) nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.4 Hip & Ridge Shingles: 6.4.1 Installation of Seal -A -Ridge, Seal -A -Ridge Armorshield and Seal -A -Ridge IR asphalt shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails per shingle. 6.4.2 Installation of Timbertex Hip and Ridge asphalt shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails per shingle and beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. 6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC — QUA9625; (847) 664-3281 END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 01506.01.08-1112 Certificate of Authorization #9503 FL10124-R10 Revision 12: 06/21 /2013 Page 4 of 4 Florida Building Code Online.;'—', Page 1,of 2 Product Manufacturer GAF Address/Phone/Email 1361 Alps Road Wayne, NJ 07470 (973) 872-4421 lindareith@trinityerd.com Authorized Signature Beth McSorley lindareith@trinityerd.com Technical Representative Beth McSorley Address/Phone/Email 1361 Alps Road - Bldg 11-1 Wayne, NJ 07470 (973) 872-4421 BMcSorley@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer (« Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/01/2014 Validated By John W. Knezevich, PE (. Validation Checklist - Hardcopy Received Certificate of Independence FL6267 R6 COI Trinity ERD CI - Nieminen - 2013.pdf Referenced Standard and Year (of Standard) Standard Year ASTM G155 2005 TAS 100(A) 1995 TAS 110 2000 Equivalence of Product Standards Certified By http:Hfloridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqu02YBW7bM8MZA... 8/23/2013 Florida Building Code Online,, Page 2,of 2 'I Sections from the Code Product Approval Method Method 1 Option D Date Submitted 06/21/2013 Date Validated 06/24/2013 Date Pending FBC Approval 07/01/2013 Date Approved 08/23/2013 Summary of Products Model, Number or Name Description 6267.1 =GAF Ventilation Products Low profile roof ridge vents Limits of Use Installation Instructions Approved for use in HVHZ: No FL6267 R6 II er061913FINAL GAF Ventilation FL6267- R6.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use. Evaluation Reports FL6267 R6 AE er061913FINAL GAF Ventilation FL6267- R6.Ddf Created by Independent Third Party: Yes Back Next Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: rCredf bra EW http://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqu02YBW7bM8MZA... 8/23/2013 EVALUATION REPORT GAF 1361 Alps Road, Building 7-3 Wayne, NJ 07470 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 01506.02.06-R6 FL6267-R6 Date of Issuance: 02/28/2006 Revision 6: 06/19/2013 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections referenced herein. DESCRIPTION: GAF Roof Ventilation Products LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 06/19/2013 This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity IERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. QOMN-ITYJERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: GAF Roof Ventilation Products, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1523.6.5.2.13 Wind Driven Rain TAS 100(A) 1995 1523.6.5.2.13.1 Physical Properties TAS 110 2000 2612.2 Weatherometer ASTM G155 2005 3. REFERENCES: Entity Examination Reference Date ATI (TST 1558) Physical Properties 01-49035.01 03/02/2004 ATI (TST 1558) Wind Driven Rain 01-44964.01 01 /15/2004 ATI (TST 1558) Wind Driven Rain 60172.01-122-18 10/07/2005 ATI (TST 1558) Physical Properties 59665.02-106-31 09/16/2005 ATI (TST 1558) Wind Driven Rain 84608.01-106-18 11 /12/2008 ATI (TST 1558) Wind Driven Rain A5250.01-109-18 02/18/2011 PRI (TST 5878) Weatherometer HBP-007-02-01 06/24/2004 PRI (TST 5878) Physical Properties HBP-002-02-01 06/06/2001 PRI (TST 5878) Wind Driven Rain HBP-01-02-01 11/02/2000 PRI (TST 5878) Wind Driven Rain BRY-021-02-01 12/31/2003 PRI (TST 5878) Physical Properties BRY-025-02-01 09/17/2004 PRI (TST 5878) Physical Properties GAF-138-02-06 02/09/2007 PRI (TST 5878) Wind Driven Rain GAF-138-02-04 02/09/2007 PRI (TST 5878) Wind Driven Rain GAF-310=02-01 07/07/2011 ETC Labs (TST 2411) Physical Properties ETC-01-718-10379.0 01 /16/2000 ETC Labs (TST 2411) Physical Properties ETC-03-718-14602.0 01 /20/2004 ETC Labs (TST 2411) Physical Properties ETC-07-718-19959.0 09/27/2007 Miami -Dade (CER 1592) Various Various NOAs Current UL, LLC. (QUA 9625) Quality Control Inspection Report 05/01/2013 4. PRODUCT DESCRIPTION: 4.1 Cobra® Exhaust VentTM is a low -profile attic ridge vent of mesh -construction for use in shingle roof systems. The product measures 10'/2-inch wide supplied in 20 and 50 ft long rolls. 4.2 Cobra@ Rigid Vent 3TM is a plastic, low -profile attic ridge vent for use in shingle roof systems with 12-inch width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch long sections, and is supplied with 3-inch ring shank nails. 4.3 Cobra@ Rigid Vent 3TM - 9" is a plastic, low -profile attic ridge vent for use in shingle roof systems with 10-inch width ridge caps. The product measures 11'/2-inch wide supplied in 48- inch long sections, and is supplied with 3-inch ring shank nails. 4.4 Cobra@ Snow CountryTM is a plastic, low -profile attic ridge vent with filter for use in shingle roof systems. The product measures 13-13/16-inch wide supplied in 48-inch long sections Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate of Authorization #9503 FL6267-R6 Revision 6: 06/19/2013 Page 2 of 8 QOTRINITYIERD 4.5 Cobra@ Snow Country Advanced TM is a plastic, low -profile attic ridge vent with filter for use in shingle roof systems with 12-inch width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch long sections, and is supplied with 3-inch ring shank nails. 4.6 Cobra@ Snow Country Advanced TM - 9" is a plastic, low -profile attic ridge vent with filter for use in shingle roof systems with 10-inch width ridge caps. The product measures 11'h-inch wide supplied in 48-inch long sections, and is supplied with 3-inch ring shank nails. 4.7 Cobra® Ridge RunnerTM is a polypropylene plastic, low -profile attic ridge vent for use in shingle roof systems. The product measures 11'h-inch wide supplied in 20 ft long rolls. 4.8 TruSlateO Ridge Vent is a plastic, low -profile attic ridge vent for use in TruSlatea roof systems. The product measures 11.4-inch wide supplied in 48-inch long sections. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ 5.2 Minimum slopes are as follows: Product Minimum Slope Cobra® Exhaust Vent 2:12 Cobra® Rigid Vent 3TM 3:12 Cobra® Rigid Vent 3TM - 9" 3:12 Cobra@ Snow CountryTM 3:12 Cobra® Snow Country Advanced TM 3:12 Cobra® Snow Country Advanced TM - 9" 3:12 Cobra@ Ridge Runner TM 3:12 TruSlate® Ridge Vent 5:12 5.3 The maximum mean roof height for Cobra® Exhaust Vent, Cobra® Rigid Vent 3, Cobra® Rigid Vent 3 - 9", Cobra® Snow Country, Cobra® Snow Country Advanced, Cobra® Snow Country Advanced - 9", Cobra® Ridge Runner and TruSlate@ Ridge Vent shall be 33 ft. 5.4 Installation shall result in minimum net free ventilation area requirements set forth in FBC Sections 1203.2 and 2326.3.2, with not less than 50% of ventilation from soffit or cornice vents. When more than one level of roof ridge existing over a single attic space, use ridge vents only at the high ridge. 6. INSTALLATION: 6.1 GAF Roof Ventilation Products shall be installed in accordance with GAF published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate of Authorization #9503 FL6267-R6 Revision 6: 06/19/2013 Page 3 of 8 j C�Q TRIM- Y I ERD 6.2 COBRA@ EXHAUST VENT: 6.2.1 Chalk a cut -line 1-inch off each side of the ridge and cut a slot along the apex of the roof measuring 2-inch (for truss construction) or 3Y2-inch (for ridge pole construction). The slot should terminate 6-inches from each end and 12-inches from hip intersections or chimneys. Cut only the sheathing; do not cut trusses. Figure A. 6.2.2 Unroll the vent along the entire length of the ridge, covering uncut 6-inch sheathing area on both ends. Shorter lengths can be joined by caulking and butting the ends. Figure B. 6.2.3 Apply a bead of polyurethane roof sealant to the underside of the entire perimeter of the vent and nail with min. 2'h-inch galvanized roofing nails at each corner and 10-inch o.c. Do not use excessive roof cement, as it may result in shingle blistering. 6.2.4 Apply a bead of polyurethane roof sealant in the shape of a "C" to the underside of the entire perimeter of the cap shingles, and install cap shingles directly over the vent using Smart Nails"' or 13/4-inch coil nails (supplied with the vent). Figure C. Do not use excessive roof cement, as it may result in shingle blistering. 6.2.5 Cobra® Exhaust Vent (hand nail version) and Cobra® Exhaust Vent (nail gun version) have a 3/4-inch or 5/8-inch nominal thickness, respectively, to facilitate ventilation. Care shall be taken not to crush or compact the product during installation. Figure D. Hand -Nail Version Exterior Research and Design, LLC. Certificate of Authorization #9503 Nail Gun Version Evaluation Report 01506.02.06-R6 FL6267-R6 Revision 6: 06/19/2013 Page 4 of 8 6.3 6.3.1 6.3.2 6.3.3 \I TRINITY I ERD COBRA® RIGID VENT 3Tm, RIGID VENT 3Tm - 9"r SNOW COUNTRYTm. SNOW COUNTRY ADVANCED TM AND SNOW COUNTRY ADVANCEDTm - 9": Mark -off and cut the slot opening as follows, ensuring that the ends of the opening stop at least 6-inch from any end walls and at least 12-inch from hip and ridge intersections or chimneys. ➢ No Ridge Board: Cut a 7/8-inch opening on each side of the ridge (Figure A). ➢ With Ridge Board: Cut a 1-5/8-inch opening on each side of the ridge (Figure B). 13/4' No Ridge Board 191 1 %11 31/4 With .RWOe Board Sealant: Apply a bead of silicone caulking or roof cement to the underside of the outer baffle along both edges and at exposed ends, ensuring the outside edges where the vent meets the shingles are sealed with the caulk or flashing cement. Vent Placement: Starting at one end of the slot, place, center and conform the Cobra® rigid vent over the slot with the vent firmly against the roof surface, ensuring the vent extends past the slot opening by at least 6-inch. 6.3.4 Fasteners: For Cobra® Rigid Vent 3T11, Cobra® Rigid Vent 3Tm - 9", Cobra® Snow Country AdvancedTm and Cobra® Snow Country Advanced TM - 9" only, use the E-Z NailTm system. Grasp attached nails by the head and peel back. Rotate nail to vertical position for easy removal. For Cobra® Snow CountryTM, use nails at least 13/4-inch or longer. Nails must always penetrate through plywood decks or at least 3/4-inch into wood planks. NOTE: GAF recommends 3-inch ring shank nails for increased uplift resistance. 6.3.5 Spacing: Attach the vent section through the pre -molded nailing holes located at 3, 12, 24, 36 and 45-inch from the start of each 48-inch vent piece. 6.3.6 Joints: Apply the subsequent Cobra® rigid vent sections over the length of the ridge using the overlap/underlap tabs. 6.3.7 Ridge Shingles: Install ridge shingles in accordance with shingle manufacturer's published installation instructions, using nails detailed in 6.3.4. A nail line is inscribed on top of the Cobra@ rigid vent to serve as a guide. Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate of Authorization #9503 FL6267-R6 Revision 6: 06/19/2013 Page 5 of 8 i C)o TRIM-r j ERD 6.4 COBRA® RIDGE RUNNERTM 6.4.1 Cut slot per 6.3.1. 6.4.2 Tear a 1-foot section to be used as a template for laying the vent out (Figure E-G) and center the template/ locator over the ridge cap shingles at the beginning of the vent slot. Note the location of the baffle (Figure H). Make sure to do this at both ends of the installation. 6.4.3 Measure the distance from the edge of the roof slot to the exterior baffle (D). Establish a chalk line along one side of the ridge (Figure 1). Unroll the vent and use the included 1-3/4- inch pneumatic roofing nails to attach the first side of the ridge vent with the exterior of the baffle aligned with the chalk line (Figure J). Proceed with using the V interval EasyTearTM system to custom size the vent to the appropriate length. If the EasyTearTM system can not be utilized, use a utility knife to size the vent. Nail gun targets are embossed on the part as a guide for property attaching vent to the roof. The vent should be fastened on 6-inch centers (Figure K). Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate of Authorization #9503 FL6267-R6 Revision 6: 06/19/2013 Page 6 of 8 C)o TRINITY I ERD 6.4.4 NOTE: When fastening the vent and cap shingles, be sure that the included 1 3/4-inch coil nails completely penetrate plywood or provide at least 3/4-inch penetration into wood planks. In the case they do not, you must use alternate nails that provide the required penetration. Proceed with attaching the other side of the vent. When beginning to nail down the second side, do NOT begin at the end; begin between the first and second one -foot sections and then return to fasten the first one -foot section. This will allow for proper fit. 6.4.5 Install ridge shingles in accordance with shingle manufacturer's published installation instructions, using the nail -lines on top of the ridge vent for proper lapping. 6.5 TRUSLATEO RIDGE VENT: 6.5.1 DO NOT use on hips. 6.5.2 Intall TruSlate@ Ridge Vent before installing the field slates. 6.5.3 After determining the total length of TruSlate@ Ridge Vent required (for proper ventilation), determine the necessary slot opening. Mark -off and cut the slot opening, ensuring the ends of the opening stop at least 6-inch from any end walls and at least 12-inch from hip and ridge intersections or chimneys. 6.5.3.1 Roofs without a ridge board: Cut a 7/8-inch opening along the ridge on each side (Figure A). 6.5.3.2 Roofs with a ridge board: Cut a 1-5/8-inch opening along the ridge on each side (Figure B). I (22 mm)lle I/a (22 mm) 13/4".(44:mm) No Ridge Board Fig'. B 141 m,.)1 �s" 18'a (41 MM 3Yf (62mm) With Ridge Board 6.5.4 Install an 18-inch wide section of ASTM D1970 self -adhering leak barrier (holding Florida Statewide Product Approval or Approved on a Local Basis) from the edge of the ridge slot extending down towards the roof deck on both side of the slot. 6.5.5 Place the TruSlate@ Ridge Vent over the ridge slot, "peaked" and centered over the ridge slot, and attach using minimum 3-inch long ring -shank nails through the pre -molded nail holes on the vent, located 3-inch from the ends and 9-inch o.c. Fasteners shall penetrate through plywood decks or embed minimum 3/4-inch into wood plank decks. 6.5.6 Continue over the length of the ridge, utilizing the male/female connectors to connect units. Ensure the finished ends include the pre -molded end caps. Cover all exposed nail heads on the vent with silicone caulk. Intall a bead of exterior grade silicone sealant at the downslope leading edges of the ridge vent, at the junction of the leading edge and the leak -barrier below. 6.5.7 Install the top course of TruSlate@ field slates, UnderBlockTM UV & Moisture Barrier and TruSlate@ trim slates in accordance with GAF published installation instructions. Intall TruSlate® .trim slates with 10-inch exposure using minimum 1-5/8-inch long deck screws through pre -drilled holes, through the ridge vent to engage the wood deck. Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate of Authorization #9503 FL6267-R6 Revision 6: 06/19/2013 Page 7 of 8 i (`n RaM Dock Pr010GOW fas�,� YVeatherkYatdi�or . SformGuartl� Lriak 9arrwr ME 7. LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate of Authorization #9503 FL6267-R6 Revision 6: 06/19/2013 Page 8 of 8