Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: DUE: RECEIPT #: Permit #: Os Planning & Development Services Department Building & Code Regulation Division �cqN 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 'J �UY Tel. 772-462-1553 Co U APPLICATION FOR ROOF PERMIT my SEE REVERSE SIDE FOR INSTRUCTIONS 1. Location/Site Address: 3401 S. Eiva r Dr • FcoI. Pirrce_ . `L 311982 2. Parcel ID Number: 2 H,16 - S0a -o0o6- oao - "j Ki 4. Descr Total Roof Area (square feet): Cp Cn 5. Roof Pitch: 6. Type of Roof. [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake /�-jShingle [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other $,fit , + Gt [ ] Product Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information ,L�o�/q�p�f�l*'�4ST 8. Contractor Information Name: keonarN peaau a¢r4 Address: 3 Nb 1 S. :T.,d:a' R i e r fir. FL Reg/Cert #: CCC 137Q08q County Cert #:g� City: Form Pi`I'cc._ State: Fl- Business Name: Miclttl J&vir, WJrL Rv4j,7"G Zip: 3 N98a Phone: (`17 a Cell Phone: (71�791--OgGG 9. Value of Construction: $ Moo WAZS41g0d'=/N 08E115 NEf "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of t information contained in this application is correct and that all work will be done in complia ith all ap r ble 1 ws regulating eonstruction and zoning. ArlIad a Ah PRINT QUALIFIERS/OWNERS NAME SIG&AT4fft OF UALIFIER/OWNER STATE OF FLORIDA, COUNTY OF, + L xA& P ACKNOWLEDGED BEFORE ME THIS 10-114n- DAY OF 20 VL_, BY 1�IC �aA \/��s► 1 WHO!RSE AqYOWN(*_TO ME OR HAS PRODUCED AS IDENTIFICATION W �Ia-I,+rYs�i ti�p1 p MATTHEW SAFFIOTI SIGAft E ARY TYPE OR PRINT NAME OF NOTARY MY COMMISSION # EE 84M COMMISSION NU BER GC SoOOD y'., o EXPIRES: October 22, 2016 RFgQ� Bonded Thru Notary Public Underwriters NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 JOSEPH E. SMITH, CLERK -r THE CIRCUIT COURT - SAINT LUCIE COU-T-1 FILE # 3923381 OR BOO 02 PAGE 1731, Recorded 02/10/20i4 '0:04 AM NOTICE OF COMMENCEMENT Permit No. Tax FoW No. ;?gJ6-5d2 -QOd6 - oao e'j State of Florida County of St. Lucie The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes. the following information is provided in this Notice of Commencement. Legal Description Property: (and street address if available►: Ef�Sl1'S * lei 4•Iest s. 81.7r ._ 7y0i 5. , Qiutr nAr, firs. fieas- r K MIZ GaNral desalpllon d improvement: r#04W . w r i I'! r�. rt 4'/ J eF - - - Owner Msformation or lessc a information H the Lessee contracted for the improvement: N fi� Aamress-Taet e.,L )_MI Interestlnproperty: rss.nr - Name and address of fee simple titleholder (if different from Owner listed above): Contractor's Name: ContractarAddrms: 141E SE sue ,;!1SI .P-1 SEE!, tit .9 JV91JPhone Number: f1W0 Surety (if applicable, a copy of the payment bond is attached): Amount of bond: S Name and address: Phone number, taodar Name: Phone Number: Lender's address: Persons within the State d Florkta designated by Owner upon whom notices or other documents may be served as pr, ldcd by Section i39,3i(11(allf. Morida Statutes Name: Phone Number: In addition to himself or herself, Owner designates d to receive a copy of the Uenoes Notice as provided in Section 7],),IN1) (b), Florida Statutes. Phone number of person or entity designated by owner: Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMi MENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART], SECTION 723.13, FLORIDA STATUTES, AND CAN RESULT I YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF CDMRENCB*NT MUST BE RECORDED AND POSTED THE JOG STTE IIE WRi THE RRST INSPEOM. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFOR COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury. I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowle and belief. 15igsttur er or Lessee, or Owne essee's Authorit c Director/P er/Manager KI �L C (Signatory's Title/Officel The foregoing instrument was acknowledged before me this's d day of20J yLeonafor iB� r Name of Person A Type of authority (e.g. officer, trustee) Party an behalf of whyd instrument was executed (Signalure o Notary Public - State of FI ' a) (Print, Type, or Stamp Commiss onedIldme of Nc h KATHRYNAUNOSEY n +.' Ca►miaslon # EE 171125 Expires May 17, 2016 t+avxa nr, rmr rw ii.v.n s ooslarote Personally ken ary Public) Type of Identrfi produced Identification_ STATE OF FI-ORIDA ST. LUCIE COIATY TW1SIS Tu (I[-R T IFY THAT THIS ESA 11'.41 E JtY�rtMld t. 0,' E C �� �"! + P'4 E. J ey. °e 'Gt�`�' 2014 Date � ■ Q3 4- "'7$7, 7F fI' s 1� 40..41 x: lob s ,s ,. 40 '&a • y .• 40 .. •.s o 5 so °a sk P a ° r n� a ?� gj��' ... •. ktp y� x Y K PW N If TO , u � Pt. ^k y, ��f q+��r�� �"�� � a""'jC' �'. s� h✓ ; - � 'Iye� wl. �, ti �'. '!iF `'.�d� :�y'm`1d. "Y w i EI•TOIL pL � I K IV A. {. S� ! �#� X` "aY � .�� ,.Fie W i`Y.. r•.'�€ �` y,Y ,� cK a ek Y � 6 y Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # IWOa -0103 I, h 6a -A 0AS6 , licensed as a(n)Contractor*/Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *General, Building, Residential o Roofing Contracto or any individual certified under 468 F.S. to make such an inspection. On or about . 031 z, /I'1 , I did personally inspect the roof deck nailing (Date) work at:3g0) T13g91,2 (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) Sign ture and Seal STATE OF FLORIDA COUNTY OF S+. Ltxcie ccc 133 oo8� License # Sworn to and subscri ed before me this 25' day of Marc% 20�, by rhee �a�s�_. who is personally known to me or who has produced as ident ca ion. Notary Public, State of Florida Signature of Notary: Commission Number:EEgLi! En 01/19/2011 MATTHEW �SAFFIOTI MY COMMISSION # EE 845800 a•, o,: EXPIRES: October 22, 2016 Bonded Thru Notary Public Underwriters RECEIVED MAR 2 6- 2014 Florida Building Code Online y Uteme efficiently. Regulate fairly. BCIS Home [ Log In ( User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email FL1654-R12 Revision 2010 Approved a POLYGLASS USA I 150 Lyon Drive Fernley, NV 89408 (570)384-1230 Ext242 jakins@polyglass.com �'W�� Ob7 LUCIE COUNTY BUILDING DIVISI9M FOR DATE • / PLAidS A ERMIT MUST. BE ICE ON JOB OR NO INSPECTION WILL BE MADE Authorized Signature James Akins jakins@polyglass.com THESE PLANS PU0 ALL PROPOSED WORK Technical Representative Steve Wadding ARE SUBJECT TO ANY CORRECTIONS Address/Phone/Email 150 Lyon Drive REQUIRED BY FIELD INSPECTORS THAT Fernley, NV 98408 MAY RE NECESSARY IN ORDER TO (602) 363-7139 stevew@polyglass.com COMPLY WITH ALL APPLICABLE CODES. Quality Assurance Representative James Akins Address/Phone/Email 555 Oakridge Road coNcMLED FASTENERS ORATTAOHMM Humboldt Industrial Pkwy Hazleton, PA 18201 THE RESPONSIB11M OF THE (800) 894-4563 yt n L eC nn jakins@polyglass.com tONTRACTOROFRECOM Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer [ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/08/2015 Validated By John W. Knezevich, PE "j Validation Checklist - Hardcopy Received http://www. floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKx... 3/19/2014 Florida Building Code Online Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved 3 �. 1LE 4\aT. et FL1654 R12 COI Trinity ERD CI - Nieminen - 2013.Ddf Standard Year ASTM D6163 2000 ASTM D6164 2005 ASTM D6222 2002 ASTM D6509 2000 FM 4470 1992 FM 4474 2004 1101t Co. fi � gs®,fq�� Method 1 Option D 08/21/2013 08/26/2013 09/08/2013 10/18/2013 Summary of Products FL # Model, Number or Name Description 1654.1 Polyglass SBS and APP SBS and APP modified _bitumen roof systems Modified Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL1654 R12 II Al ER082113FINAL POLYGLASS MODBIT FL1654- R12.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this Evaluation Reports application relates to one particular assembly FL1654 R12 AE ER082113FINAL POLYGLASS MODBIT FL1654- R12.Ddf over concrete deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer Created by Independent Third Party: Yes to ER, Section 5 for other Limits of Use. Back Plext Contact Us :: 1940 North Monroe Street Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012,.licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public, record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: go M EGlaxck http://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKx... 3/19/2014 °Q A ENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866) 784-8550 xwww.floridaenginceringandtesting.com 250 S.W.13t" Avenue ILE OPY Pompano Beach, FL 33069 DATE: 3/14/14 JOB ORDER #: 14-878 CLIENT."Michael Kevin Walsh Roofing ADDRESS: 3520 S.W. Armellini Avenue - C1 Palm City, Florida 34990 PROJECT: Berg Residence Flat Wood Roof Deck ADDRESS: 3401 Indian River Drive Fort Pierce, Florida FEC 2010/ASCE 7-10 DESIGN PRESSURE CALCULATIONS Proiect Information: Height = 15' Exposure: D Basic/Ultimate Wind Speed: VuIt=165 mph Length = 46' Category: 11 Nominal Wind Speed: Vasd=VWt*�0.6 Width = 12' Slope: < 7° (asd = allowable strength design) Parapet Wall: < 3' Residential KZ = 1.03, Kzt = 1.0, Kd = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*KZKZtKdV2 Velocity Pressure (utl): q=0.00256(1.03)(1.0)(0.85)(165)2] = 61.02 psf Velocity Pressure (asd): q=0.00256(1.03)(1.0)(0.85)(165*g0.6)2] = 36.61 psf Width of Pressure Coefficient: 0.1(16') = 1.6' 0.4(15') = 6.0' ) use: 3'0" Effective Wind Area: <1Oft2 For parapet height three feet (3) or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure Coefficient: 1) GCP; _ 0.18 r `\ 1 f 7 +�, U« Qualilr,/ �, � ✓l trance Page 2, 3/14/14, Job Ordr,_14-878 F 0 Michael Kevin Walsh Roofing - Berg Residen tU fi ' Ld 1 ` Flat Residential Wood Roof Deck 3401 Indian River Drive; Fort Pierce, FL: F1 t° y Design Pressures Based on Vasd: 1) Field P 1 = 36.61 * [(-1.0) — (0.18)] = -43.2 psf 2) Perimeter P2 = 36.61 * [(-1.8) — (0.18)] = -72.5 psf 3) Corners P3 = 36.61*[(-2.8) — (0.18)] = -109.1 psf Attachment Requirements Per RAS-117: Based on the requirements of Florida Product Approval # FL1654-R12, Appendix 1, pg 10 of 31, System #W-33, with a maximum design pressure of-60.0psf; the following are our recommended fastening patterns to attach the proposed Elastobase or Elastobase P base sheet to the wood deck utilizing approved OMG Flat Bottom Plates (square) with Roofgrip # 12 fasteners: Field: 12" o.c. @ 4" laps and 2 staggered rows 12" o.c. Perimeter: 12" o.c. @ 4" laps and 3 staggered rows 12" o.c. Corners: 12" o.c. @ 4" laps and 5 staggered rows 12" o.c. Notes: Corners and perimeter area dimension shall not be less than a = 3'0" LIAR 19 2014 Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2010 Edition. Wind load calculations based on ASCE 7-10, FBC 2010 and information provided by client. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely, Mark A. Mesiano, P.E. Florida Engineering & Testing, Inc. Florida Reg. No. 48202 Certificate of Authorization No. 6923 Q(T_�P`xINI7Y I E R D APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4-5 IA-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 7 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 7 1D Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 8 1E Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 9-11 1F Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover it 2A Steel or Conc. New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12 2B Steel or Conc. New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 13 2C Steel or Conc. New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14 3A-1 Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 15-18 3A-2 Concrete New or Reroof (Tear -Off) A-1 Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover 18-19 3B Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 19 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 20-21 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 21 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 22-24 5A CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 25 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 26 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 27 5D CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 27 SE CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 27 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 28 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 28-29 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 29 6D . Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 29 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 30-31 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 31 The following notes amily to the systems outlined herein: 1. Roof decks shall be in -accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocya n u rate, polystyrene, wood fiberboard, perlite, DensDeck, DensDeck Prime, DensDeck DuraGuard, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the QA requirements of F.A.C. Rule 9N-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. Exterior Research and Design, LLC. d/b/a TrinitylERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report P9290.02.08-R10 for FL1654-R12 Revision 10: 08/21/2013 pen 1, ge 1 of 31 QiTRINITYIERD Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ HA (HA): Full coverage at 25-30 Ibs/square. ➢ Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: 01y8ond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ 3M CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. Note: TITESET may be used where CR-20 is referenced. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanu rate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA) ➢ OMG OlyBond 500 (OB500): ➢ OMG OlyBond 500 (OB500): ➢ OMG OlyBond 500 (OB500): ➢ OMG OlyBond 500 (OB500): ➢ 3M CR-20: MDP -157.5 psf (Min. 0.5-inch thick) MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL) MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) MDP -487.5 psf (Min. 0.5-inch thick ACFoam II) MDP -117.5 psf (Min. 1.0-inch thick) 7. Bonded polyisocya nu rate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124. 12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. Exterior Research and Design, LLC. d/b/a TrinitylERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report P9290.02.08-R10 for FL1654-R12 Revision 10: 08/21/2013 Appendix 1, Page 2 of 31 L'E!� 0 PY TTpINI"('YIERD 13. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. TABLE 1: POLYGLASs ROOF COVERS Reference Layer Material Application BP -AA Base Polyglass G2 Base, FBC Approved ASTM D4601, Type II HA at 20-40 Ibs/square (Base and Ply sheets, Asphalt -Applied) Ply FBC Approved ASTM D2178, Type IV or VI or ASTM D4601, Type II SBS-AA Base or Ply Elastobase, Elastobase Poly, Elastoflex V, Elastoflex S6 HA 20-40 Ibs/square (SBS, Asphalt -Applied) Cap Elastoflex S6, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko MOP, Polyfresko MOP FR at Base or Ply Elastoflex V, Elastoflex S6 SBS-TA Elastoflex V, Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko MOP, Torch -Applied (SBS, Torch -Applied) Ca P Polyfresko MOP FR SBS-SA Base Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR Self (SBS, Self -Adhering) Cap Elastoflex SA P, Elastoflex SA P FR, Polyfresko SBS SAP, Polyfresko SBS SAP FR -Adhering APP-TA Base or Ply Polyglass APP Base, Polyflex, Polybond Torch -Applied (APP, Torch -Applied) Cap Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko Torch, Polyfresko Torch FR APP-SA Cap Polyflex SA P, Polyflex SA P FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Polykool, Polybianko Self -Adhering (APP, Self -Adhering) 14. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating; ➢ PG300 Fibered Roof Coating or Mule -Hide 102 Fibrated Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating; ➢ PG700 White Reflective Roof Coating; ➢ PG800 Non-Fibered Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Fibrated; ➢ PG850 Fibered Asphalt Emulsion Roof Coating or Mule -Hide 301 Emulsion Fibrated; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating; ➢ Polybrite 70 White Elastomeric Roof Coating. 15. The following represent priming requirements for gypsum -based coverboards: ➢ DensDeck and DensDeck Prime shall be field -primed with PG100 prior to self -adhering or torch -applied membrane application. No priming is required for hot -asphalt membrane applications. ➢ SECUROCK Gypsum -Fiber Roof Board or DensDeck DuraGuard do not require field priming for any membrane application. 16. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a Trinity]ERD _ Evaluation Report P9290.02.08-R10 for FL1654-R12 Certificate of Authorization #9503 "i i= .v Revision 10: 08/21/2013 Appendix 1, Page 3 of 31 Prepared by: Robert Nieminen, PE-59166 0 TABLE 1E: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck (See Note 1) Base Sheet Roof Cover MDP Base Fasten Attach Ply Cap No. (psf) Min. 19/32-inch plywood at max. 24-inch spans Elastobase or Elastobase Poly with 32 ga., 1-5/8-inch diameter tin 8-inch o.c. in 4-inch lap and 8- (Optional) One or SBS-SA,, APP-SA W-31 attached 4-inch o.c. with poly top surface caps with it ga, annular ring inch o.c. in three, equally more SBS-SA, SBS- SBS-TA or -60.0 8d common nails or 6-inch shank nails spaced, staggered center rows TA or APP-TA o.c. with #8 screws APP-TA Min. 19/32-inch plywood (Optional) One or at max. 24-inch spans OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap and more BP -AA, SBS-AA, W-32 attached 4-inch o.c. with Elastobase or Elastobase Poly with Roofgrip #12 12-inch o.c. in two, equally AASBS-TA orr AP APP- SBS-TA, -60.0 8d common nails or 6-inch spaced, staggered center rows TA APP-TA o.c. with #8 screws Min. 19/32-inch plywood a 0 1 W-33 at max. 24-inch spans attached 4-inch with Elastobase or Elastobase Poly with OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap and 12-inch o.c. in two, equally One or more SBS- SA, SBS-TA or APP- SBS-SA, APP-SA, -60.0 8d common nails or 6-inch or Poly top surface with Roofgrip #12 spaced, staggered center rows TA SBS-TA or o.c. with #8 screws APP-TA Min. 15/32-inch thick exterior grade plywood 6-inch o.c. at 2-inch lap and 6- (Optional) BP -AA, SBS-AA, W-34 attached per Code to meet Elastobase Simplex MAXX Cap inch o.c. in two, equally SBS-AA, SBS-TA or SBS-TA or -90.0 pressure requirements. spaced, staggered center rows APP-TA APP-TA Min. 15/32-inch thick OMG #12 Standard Roofgrip or exterior grade plywood OMG #14 Heavy Duty (min. 1- 6-inch o.c. at 4-inch lap and 6- W-35 attached per Code to meet Polyglass APP Base 5/8-inch long) with OMG 3" inch o.c. in three, equally (Optional) APP-TA APP-TA -90.0 pressure requirements. Round Metal Plates or OMG Flat spaced, staggered center rows Bottom Metal Plates Min. 15/32-inch thick OMG #12 Standard Roofgrip or exterior grade plywood OMG #14 Heavy Duty (min. 1- 6-inch o.c. at 4-inch lap and 6- (Optional) BP -AA, SBS-AA, W-36 attached per Code to meet Elastobase (with sand top surface) 5/8-inch long) with OMG 3" inch o.c. in three, equally SBS-AA, SBS-TA or SBS-TA or -90.0 pressure requirements. Round Metal Plates or OMG Flat spaced, staggered center rows APP-TA APP-TA Bottom Metal Plates Min. inch thick exteriorfor grade plywood Trufast #12 DP orTrufast #14 6-inch o.c. at 4-inch lap and 6- (Optional) BP -AA or W-37 attached per Code to meet Elastobase (with sand top surface) HD (min. 1-5/8-inch long) with inch o.c. in three, equally SBS-AA SBS-AA -90.0 pressure requirements. Trufast 3" Metal Insulation Plates spaced, staggered center rows Min. 19/32-inch plywood at max. 24-inch spans Elastobase or Elastobase Poly with 32 ga., 1-5/8-inch diameter tin 4-inch o.c. in 4-inch lap and 4- (Optional) One or SBS-SA, APP-SA, W-38 attached 6-inch o.c. with poly top surface caps with 11 ga, annular ring inch o.c. in four, equally more SBS-SA, SBS- SBS-TA or -97.5 #8 screws shank nails. spaced, staggered center rows TA or APP-TA APP-TA Min. inch thick exteriorfor grade plywood 6-inch o.c. at 2-inch lap and 6- (Optional) BP -AA, SBS-AA, W-39 attached per Code to meet Elastobase Simplex MAXX Cap inch o.c. in three, equally SBS-AA, SBS-TA or SBS-TA or -105.0 pressure requirements. I I Ispaced, staggered center rows APP-TA APP-TA Exterior Research and Design, LLC. d/b/a Trinity]ERD '�� CCPY Evaluation Report P9290.02.08-R10 for FL1654-R12 Certificate of Authorization #9503 Revision 10: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 10 of 31 �I I 'r �! ri -.'. Joe Cido From: Joe Cicio Sent: Tuesday, March 04, 201411:03 AM To: 'walshroof ing@bellsouth.net' Cc: 'leonardberg@comcast.net'; Joe Cicio Subject: Review comments for Permit Number 1402-0103 Attachments: Report_FL_Review_Comments_Noncompliantjrf[1].pdf Dear St. Lucie County Permit Applicant, Please see the attached plan review comments which have been generated for your permit. As soon as we receive the modified plans and any additional required documentation back from the design professional , contractor or owner we will perform the additional reviews as necessary in order to complete the plan review process. Once the plans have been signed, by all applicable plan reviewers, we will move the permit forward either to the Fire Department or back to permitting for permit issuance. Thank you, Joseyk. )K. e4Cio Plates Examiler11 Standard Building Inspector Building Plans Examiner One and Two FamtlyDwelling lnspector One and Two Family Plans Examiner St. Lucie County Platvting and Development Services 772-462-1553 Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and / or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue, Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 3401 Indian River Dr City / State / Zip: Fort Pierce, FI 34982 Parcel #: 2426-502-0006-000/7 Zoning: RE-2 APPLICATION INFORMATION Permit Number: 1402-0103 Permit Type: ROOF PERMIT - OTHER CONTRACTOR INFORMATION Contractor Name: Michael K Walsh Business Name: Michael Kevin Walsh Roofing Inc Business Addr: 1926 Se Doverbrook St City / State / Zip: Port St Lucie, FI 34983 REVIEWS AND COMMENTS REVIEW COMMENTS 1 Owner(s): Leonard Berg / Peggy W Berg Jurisdiction: ST LUCIE COUNTY Lot#: 4 Block: Stories: Automatic Sprinkler System? No Fax Number: 772-781-0901 Email: Walshroofing@Bellsouth.Ne t Review Type Status Reviewed By Date Started Date Completed Date Released FRONT COUNTER REVIEW COMPLETE Angela Huff 2110/2014 2/10/2014 2110/2014 Comment: PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 3/4/2014 Comment: NEED IDENTIFICATION OF THE 3 PRESSURE ZONES W/ DUPLICATE ROOF SCHEMATICS' INCLUDE ALL 3/4/2014 DIMENSIONS AND FASTENER ENHANCEMENTS AS REQUIRED 3/4/2014 Comment: THIS IS IN A 165 M.P.H. ZONE EXPOSURE "D" 3/4/2014 Comment: ROOF DECKING MUST BE SCREWED TO 19/32" PLYWOOD DECK PER DESCRIPTION 3/4/2014 Comment: PLS ADDRESS THE ROOF EQUIPMENT ON THE FRONT FLAT AREA 3/4/2014 Comment: COMMENTS MAILED AND E-MAILED AS OF THIS DATE 0 0 Joe Cicio From: Sent: To: Cc: Subject: Good afternoon, Joe Cicio Tuesday, March 18, 2014 2:45 PM walshroofing@bellsouth.net Joe Cicio Permit Number 1402-0103 Please submit the original, signed, dated and sealed engineering in duplicate for this project Thank You Jaseyk. )t. Cicio Plans Examiner II Standard Building Inspector Building Plans Examiner One and Two Family Dwelling Inspector One and Two Family Plans Examiner St Lucie County Planning and Development Services 772-462-1553 Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records available to the public and media upon request. It is the policy of St. Lucie County that all County records shall be open for personal inspection, examination and or copying. Your e-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Planning & Development Services Building & Code Regulation Division. 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:( 721462.2172 Fax:(7721462.6443 fflegRTY INFORMATIQIt( Address: 3401 Indian River Dr City / State I Zip: Fort Pierce, FI 34982 Parcel#: 2426-502-0006-000/7 Zoning: RE-2 APPLICATION INFORMATION Permit Number, 1402-0103 Permit Type: ROOF PERMIT - OTHER CONTRACTOR INFORMATION Contractor Name- Michael K Walsh Business Name: Michael Kevin Walsh Roofing Inc Business Addr: 1926 Se Doverbrook St City / State / Zip: Port St Lucie, FI 34983 REVIEW COMMENTS e1 Owned$): Leonard berg / Peggy W Berg. Jurisdiction: ST LUCIE COUNTY LOW- 4 Block: Stories: Automatic Sprinkler System? No Fax Number: 772-781-0901 Email: Walshroofing@Sellsouth.Ne t REVIEWS AND COMMENTS Review = Status Reviewed By DataStettttd Pate Completed Date R®leas®d FRONT COUNTER REVIEW COMPLETE Angela Huff 211012014 2/10/2014 2/1012014 Comment: PLANS EXAMINER REVIEW INCOMPLETE doe CICIa 3/4/2014 3/4/2014 Comment: NEED IDENTIFICATION OF THE 3 PRESSURE ZONES W/ DUPLICATE ROOF SCHEMATICS * INCLUDE ALL DIMENSIONS AND FASTENER ENHANCEMENTS AS REQUIRED 3/4/2014 Comment: THIS IS IN A 165 M.P.H. ZONE EXPOSURE "D" 3/4/2014 Comment: ROOF DECKING MUST BE SCREWED TO 19182" PLYWOOD DECK PER DESCRIPTION 3/4/2014 Comment: PLS ADDRESS THE ROOF EQUIPMENT ON THE FRONT FLAT AREA 3/4/2014 Comment: COMMENTS MAILED AND E-MAILED AS OF THIS DATE �41L41 ST LUCIE COUNTY BUILDING Pre•Revieived Not in Compiianco Revioved By: G Date, o_%?. ot/. MIGi--A• L- }/.EVIN WALSf- 1z00FINC-1 INC. 3520 SW Armellini Ave. #C1 Palm City, FL 34990 (877) 597-ROOF (772) 781-0900 PHONE (772) 781-0901 FAX Email: WALSHROOFING aCBELLSOUTH.NET FAX 77�-A N,S M I TTA L- 7=0 aM TO: FROM: Walsh Roofing NAME: DATE SENT: 0311812014 PHONE: NUMBER OF PAGES: 4 FAX: FAX: (772) 781-0901 Subject: Permit Application Additional Information Message: Following is the requested information for permit application 1402-0103. "WATERTIGHT EVERY NIGHT" %L ENGINEERING &TESTING, INC. Phone: (866) 781-6889 *Fax: (866) 784-8550 ww`v.tloridaengineeringandtesting.com 250 S.W.13`h Avenue Pompano Beach, FL 33069 DATE: 3/14/14 JOB ORDER ##: 14-878 CLIENT: Michael Kevin Walsh Roofine ,ADDRESS: 3520 S.W. Armellinx ,Avenue - C1 Palm City, Florida 34990 PROJECT: Berg Residence Flat Wood Roof Deck ADDRESS: 3401 Indian River Drive _ Fort Pierce, Florida FDC 2010/ASCE 7-10 DESIGN PRESSURE CALCULATIONS Project Information: Height = 15' Exposure: D Length ^ 46' Category: If Width = 12' Slope: < 7° Parapet Wall: < 3' Residential Design Calculations: Basic/Ultimate Wind Speed; Vurt=165 mph Nominal Wind Speed: Vasd=Vuit*0.6 (asd = allowable strength design) Kz = 1.03, Kzt =1.0, Kd = 0.85 Velocity Pressure: q = 0.00256*KZKZtK.dV2 Velocity Pressure (uti): q=0.00256(1.03)(1.0)(0.85)(165)21 = 61.02 psf Velocity Pressure (.d): q=0.00256(1.03)(1.0)(0.85)(165*0.6)2) = 36.61 psf Width of Pressure Coefficient: 0.l(16') = 1.6' 0.4(15') = 6.0' ) use: 3'0" Effective Wind Area: <lW For parapet height three feet (3') or larger, zone three (3) shall be treated as zone two (2). External Pressure Coeffick-At: 1) GCP1 = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure, Coefficient: 1) GCP; = 0.18 Qtcalzty ,l�t� �� ./�8srararece Page 2, 3/14/14, Job 091041,4-878 Mchael Kevin Walsh Roofing - Berg Residence Flat Residential Wood Roof Deck 3401. Xndian River )Drive; Fort Pierce, FL-- Desian Pressures Based on Vasa: 1) Field P1 = 36.61*[(-1.0) — (0.18)] = -43.2 psf 2) Perimeter P2 = 36.61*[(-1.8) -- (0.18)] -72.5 psf 3) Comers P3 = 36.61*[(-2.8) — (0.18)] _ -109.1 psf Attachment Requirements Per RAS-I17: Based on the requirements of Florida Product Approval # FL1654-R12, Appendix 1, pg 10 of 31, System #W-33, with a maximum design pressure of-60.Opsf; the following are our recommended fastening patterns to attach the proposed Elastobase or Elastobase P base sheet to the wood deck utilizing approved OMG Flat Bottom Plates (square) with Roofgrip # 12 fasteners: Field: 12" ox. @ 4" laps and 2 staggered rows 12" o.c. Perimeter: 12" o.c. @ 4" laps and 3 staggered rows 12" o.c. Corners: 12" o.c. @ 4" laps and 5 staggered rows 12" o.c. Notes: Corners and perimeter area dimension shall not be less than a = TO" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2010 Edition. Wind load calculations based on ASCE 7-10, FBC 2010 and information provided by client. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sinmiely, " Mark A. Mesiano, P.E. Florida Engineering & Vesting, Inc. Florida Reg. No. 48202 Certificate of Authorization No. 6923 i DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DMSION NOTICE OF ACCEPTANCE (NOA Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy ST. LUCK COUN"BUILDING D ION Pre -Reviewed Not SCOPE:+�i4iaps�.a This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Self -Adhered Roof System over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 12-0818.07 and consists of pages 1 through 26. The submitted documentation was reviewed by Alex Tigera. NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 1 of 26 ROOFING ASSEMBLY APPROVAL Category Roofing Sub -Category: Modified Bitumen Materials SBS/APP/TPO Deck Type: Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Elastobase 65' 2" x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Type I base sheet. Elastobase P 5' 2" x 3' 3-3/8" ASTM D 6164, SBS modified asphalt coated polyester reinforced base Type I sheet. Elastoflex SA V FR 32' 6" x 3' 3-3/8" ASTM D 6163, Self -adhered, fiberglass reinforced, SBS modified (1.5-mm) Type I bitumen membrane with a self -adhering back face and a smooth top surface. Elastoflex SA V 32' 6" x 3' 3-3/8" ASTM D 6163, Self -adhered, fiberglass reinforced, SBS modified PLUS FR Type I bitumen membrane with a self -adhering back face and a smooth top surface. Elastoflex SA V (1.5- 32' 6" x 3' 33/8" ASTM D 6163, Self -adhered, fiberglass reinforced, SBS modified mm) Type I bitumen membrane with a self -adhering back face and a smooth top surface. Elastoflex SA V 32' 6" x 3' 33/$" ASTM D 6163, Self -adhered, fiberglass reinforced, SBS modified PLUS Type I bitumen membrane with a self -adhering back face and a smooth top surface. Elastoflex SA P FR 32' 6" x 3' 3-3/8" ASTM D 6164, Self -adhered, polyester reinforced, SBS modified Type I bitumen membrane with a self -adhering back face and a granule top surface. Elastoflex SA P 32' 6" x 3' 3-3/8" ASTM D 6164, Self -adhered, fiberglass reinforced, SBS modified Type I bitumen membrane with a self -adhering back face and a granule top surface. Polyflex SA P 32' 6" x 3' 33/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified Type I bitumen membrane with a self -adhering back face and a granule top surface. Polyflex SA P FR 32' 6" x 3' 33/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified Type I bitumen membrane with a self -adhering back face and a granule top surface. Polyfresko SBS SAP 32' 6" x 3' 33/8" ASTM D 6164, Self -adhered, fiberglass reinforced, SBS modified Type I bitumen membrane with a. self -adhering back face and a granule top surface. NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 2 of 26 Polyfresko SBS SAP 32' 6" x 3' 33/8" ASTM D 6164, Self -adhered, fiberglass reinforced, SBS modified FR Type I bitumen membrane with a self -adhering back face and a granule top surface. Polyfresko APP SAP 32' 6" x 3' 33/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified Type I bitumen membrane with a self -adhering back face and a granule top surface. Polyfresko APP SAP 32' 6" x 3' 33/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified FR Type I bitumen membrane with a self -adhering back face and a granule top surface PolyKool 32' 10" x 3' 33/8" ASTM D6222 Self -adhered, polyester reinforced, APP modified Type I bitumen membrane with a self -adhering back face and a white film laminate on the top surface. PG325 Cold Process 1, 3, 5, 50, 55 gal. or ASTM D3019 Adhesive tube Type III PG100 Asphalt Primer 1, 3, 5, 50, 55 gal, ASTM D41 tube or 17 oz. spray can PG350 Mod Bit 1, 3, 5, 50, 55 gal. or ASTM D3019 Adhesive tube Type III PG400 Plastic Roof 1, 3, 5, 50, 55 gal. or ASTM D4586 Cement tube ASTM D3409 PG425 Wet/Dry Roof Cement PG450 Flashing Cement PG500 MB Flashing Cement Polyplus 35 Premium Mod Bit Adhesive Polyplus 45 Premium Flashing Cement Polyplus 50 Premium MB Flashing Cement Polyplus 55 Premium Modified Flashing Cement 1, 3, 5, 50, 55 gal. or ASTM D4586 tube ASTM D3409 1, 3, 5, 50, 55 gal. or ASTM D4586 tube A fibered cold process adhesive for use with roll or BUR roofing. A penetrating solution of solvent and a blend of selected asphalts used to promote adhesion. A fibered rubberized adhesive designed for use with modified bitumen membranes. A thick, fibered, rubberized flashing cement for use in dry or damp conditions. A thick, fibered, rubberized flashing cement for use in dry or damp conditions. A thick, fibered, rubberized flashing cement. 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement for use tube with modified bitumen membranes. 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with tube Type III modified bitumen membranes. 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement. tube 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement for use tube with modified bitumen membranes. 1, 3, 5, 50, 55 gal. or ASTM D4586 A mastic compound for use as a roof flashing tube adhesive. NOA No.: 13-0514.10 MIAMI•DADE COUNTY Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 3 of 26 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) Polytherm-H Polyisocyanurate foam insulation Polyglass USA, Inc. Polytherm Polyisocyanurate foam insulation Polyglass USA, Inc. Polytherm Composite Polyisocyanurate/perlite composite insulation. Polyglass USA, Inc. ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp High Density Wood Fiberboard Wood fiber insulation board Generic Perlite Insulation Perlite insulation board Generic Type X Gypsum Fire resistant rated gypsum. Generic DensDeck, DensDeck Prime Gypsum insulation board Georgia-Pacific H-Shield Polyisocyanurate foam insulation Hunter Panels, LLC H-Shield CG Polyisocyanurate/perlite composite insulation Hunter Panels, LLC ENRGY-3, JM ISO 3 Polyisocyanurate foam insulation Johns Manville Corp. Fesco Board Expanded mineral fiber Johns Manville Corp. Multi -Max FA-3 Polyisocyanurate foam insulation Rmax Operating, LLC. SECUROCK Gypsum -Fiber Roof Board Fiber reinforced coverboard United States Gypsum Corporation NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 4 of 26 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Dekfast Fasteners #12, #14 Insulation fastener for wood, SFS Intec, Inc. & #15 HS steel and concrete decks 2. Dekfast Galvalume Steel Galvalume hex stress plate. 2 7/8" x SFS Intec, Inc. Hex Plate 3 '/4" 3. Dekfast Dekflat Round Polypropylene locking 3" x 3 1/4" SFS Intec, Inc. Plastic Lock Plate plate. 4. #12 & #14 Roofgrip Insulation and membrane Various OMG, Inc. fastener 5. Flat Bottom Metal Plate A2-SS aluminized steel plate 3" square OMG, Inc. 6. Plastic Plate Polyethylene stress plate 3.2" round OMG, Inc. 7. Tru-Fast #14 HD Fastener Insulation fastener for steel and Altenloh, Brinck & Co. wood decks U.S., Inc. 8. Tru-Fast 3" Metal Insulation Round Galvalume AZ50 steel 3.23 round Altenloh, Brinck & Co. Plate plate 3" round U.S., Inc. 9. Polygrip Fasteners #12, #14 Insulation fastener for wood, Various Polyglass USA, Inc & #15 steel and concrete decks 10. Polygrip Hex Plates Galvalume hex stress plate. 2 '/8" x Polyglass USA, Inc 3 I/4" 11. Dekfast Galvalume Steel 3 3" round galvalume AZ50 steel 3" round SFS Intec, Inc. in. Round plate 12. Millennium One -Step TM Insulation Adhesive Various Adco Products Foamable Adhesive NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 5 of 26 APPROVED SURFACING: TABLE 4 Product Product Name Description PG200 Non-Fibered Roof Coating A non fibered asphaltic coating used to add life and rejuvenate existing BUR roofing substrates. PG300 Fibered Roof Coating An asphalt cutback fibered roof coating. May be applied by brush or spray equipment to rejuvenate aged BUR PG600 Non-Fibered Aluminum Non-fibered aluminum roof coating. Roof Coating PG650 Fibered Aluminum Roof Fibered aluminum roof coating. Coating PG700 White Elastomeric Roof A premium white elastomeric acrylic Coating based roof coating (water -based). A polyester fabric may be used for reinforcement with this coating. PG800 Non-Fibered Asphalt An asphalt base, un-fibered clay Emulsion Roof Coating emulsion PG850 Fibered Asphalt Emulsion An asphalt base, fibered clay Roof Coating emulsion Polyplus 65 Premium Fibered Fibered aluminum roof coating. Aluminum Roof Coating Polyplus 60 Premium Non- Non-fibered aluminum roof coating. Fibered Aluminum Roof Coating Polybrite 70 White Elastomeric A premium white elastomeric acrylic Roof Coating based roof coating (water -based). A polyester fabric may be used for reinforcement with this coating. Gravel To be installed in a flood coat of approved asphalt at 60 lbs/sq Slag To be installed in a flood coat of approved asphalt at 60 lbs/sq Application Rate 1'/2-2 gal/sq Specification Manufactur er TAS 140 Polyglass USA, Inc. 11/2-2 gal/sq ASTM D4479 1/Z-1 gal/sq ASTM D2824 Type I 1'/2-2 gaUsq ASTM D2824 Type III 1-1'/z gal/sq ASTM D6083 3 gaUsq in ASTM D1227 two coats 3 gaUsq in ASTM D1227 two coats 11/2-2 gal/sq ASTM D2824 Type III '/2-1 gal/sq ASTM D2824 Type I 1-11/z gal/sq ASTM D6083 400lbs/sq N/A 300lbs/sq N/A Polyglass USA, Inc. Polyglass USA, Inc. Polyglass USA, Inc. Polyglass USA, Inc. Polyglass USA, Inc. Polyglass USA, Inc. Polyglass USA, Inc. Polyglass USA, Inc. Polyglass USA, Inc. Generic Generic NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 6 of 26 EVIDENCE SUBMITTED: Test Agency Test Name/Report Report No. Date Factory Mutual Research 4470 J.I. 2W7A7.AM 08.04.94 Corporation 4450 2D5A9.AM 06.22.99 4470 J.1. 3001334 02.15.00 4470 J.1. 3000857 01.12.00 4470 J.1. 3004091 01.12.00 4470 3012321 07.29.07 4450 3014751 08.27.03 4450 3019317 06.30.04 4470 3014692 08.05.03 Trinity ERD TAS 114 11752.09.99-1 02.08.00 TAS 114 02764.09.05 09.09.05 TAS 114 020843.02.05-1 02.10.05 TAS 114 02762.03.05 03.30.05 TAS 117(B)-ASTM D903 020841.06.04 06.02.04 TAS 114 P1734.07.06-R1 02.27.07 TAS 114 02843.07.07 07.23.07 TAS 114 P1738.02.07 02.05.07 TAS 114 P1739.01.07 01.23.07 TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07 ASTM D6164 / ASTM D6222 P10490.08.08 08.13.08 ASTM D6164 / ASTM D6222 P10490.10.08-R1 10.03.08 ASTM D6222 P7400.03.08-R2 10/09/08 TAS 114(D) — ASTM D1876 P10070.10.08 10/09/08 ASTM D6222 P10490.10.08-2 10/30/08 FM 4470 & TAS 114 P33970.03.11 03/15/11 ASTM D6163 / ASTM D 4601 P33960.03.11 03/15/11 ASTM D6164 P37590.07.13-1 07/02/13 ASTM D6164 P37590.03.13-3A 03/06/13 ASTM D6163 P37590.03.13-2-R1 02/05/13 ASTM D6222 P37590.09.13 0912/13 PRI Asphalt Technologies ASTM D6222 PUSA-061-02-02 01/28/08 ASTM D6222 PUSA-062-02-02 12/04/08 ASTM D6163 PUSA-064-02-02 02/27/08 NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 7 of 26 Membrane Type: SBS/APP Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24" o.c. and to blocking members spaced 48" o.c. with TruFast TP #IOx2-7/8" screws spaced'6" o.c. System Type E(4): Base sheet is mechanically attached to roof deck. All General and System Limitations apply. Base Sheet: One ply of 91astobase or Elastobase P fastened to the deck as described below: Fastening: Attach base sheet using 12 ga. ring shank nails and tin caps spaced 4" o.c. in a 4" lap and 4" o.c. in four equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies oClastoflex SA� Elastoflex SA V PLUS, Elastoflex SA V FR, or Elastoflex SA V PLUS FR self -adhered. Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FRj �lastof'exv§A�P�, Elastoflex SA P FR self adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -97.5 psf, (See General limitation #7.) NOA No.: 13-0514.10 MIAMMADECOUNTY Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 23 of 26 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 2751bf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 2751bf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) END OF THIS ACCEPTANCE NOA No.: 13-0514.10 MIAMI•DADECOUNTY Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 26 of 26 7, 41. -4. JA— *2013 Google Gooste earth tz