Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSME PERNIIT PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUMI)ING & CODE REGULATIONS DIVISION. 2300 M.Minia Avenue S Fort Pierce, FL 34982 SC (772) 462-1553 St. e ), 'D APPLICATION FOR REPLACEMENT OF C Uc/0 CoU� ., WINDOWS, SKYLIGHTS, SWING DOORS, SLIDING GLASS DOORS 11' & OVERHEAD GARAGE DOORS 1. LOCATION/SITE ADDRESS: 2. PARCEL ID NUN BER: 3. DESCRIPTION OF PROJE T OR WORK ACTWITY: k)a �- 4. TYPE OF S C;W SFR MOBILE HOME OTHER 5. OWNERS INFORMATION 6. Name:J�! _ Address: z q v � _ J° tate: zip; j f G� `L, ,Phone: ` Email: CONTRACTOR'S INFORMATION FL Reg/Cert #: c� c--j G J !Hl b — County Cert #• qz�2 BusinessName:tV,-'v-2 am tm Phone Number: (33 33 tA: Email: 1(� n coves to the product being used. Attach 2 copies of the Product. Approval with details VALUE OF CONSTRUCTION: $ ` �� - as FEES DUE: OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zonin . F'A�� SIGNATURE OF OWNER ONTRACTOR/QIIALIFFIER P OWNER ORCONTRACTOWQV NAME STATE OF FLORIDA, COUNTY OF - ACK—NOWLEDGED BEFORE ME THIS �—DAY OF rG 4 2.* PERSONAI.L KNOWN O ME OR WHO HAS PRODUCED AS IDENTIFICATION. �,,�r �v �Zd 05 LS r° :.•..��, PEDRO M. ALON80 ATURE OF OTARY TYPE OR PRINT NAME OF NOTARY SOMMISSION # EE 061240 *'g* EXPIRES:. February 23, 2015 TIME: NOT Y PUBLIC COMMISSION NUMBER, �O! Bonded Thru Budget Notary Services NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TRICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF Commm MBNT. .. 4 ST. LUCIE COUNTY Vinyl Siding INSTRUCTIONS Please complete all information in the space provided All information must be Printed (use black or blue ink only) or Typed. This application for replacement of Windows, Skylights, and Doors is to be used only for those activities that are not otherwise included under a primmy building permit. This application for Permit may not be used for any activity that includes any type or kind of structural alteration. Building activities involving structural alteration, in addition'to the replacement of Windows, Skylights, Doors & Overhead Garage Doors, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. LOCATION/SITE ADDRESS: .............................................. Indicate the street address, or general location, of the property on which the building activity is taking place. 2. PARCEL ID NUMBER........................................................ Indicate the Property Tax Identification Number for the property on which the building activity is taking place. 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY........ Briefly describe the building activity under permit application. 4. OWNERS INFORMATION: ................................................. indicate the name and address of the owner of the property on which — the product is to be installed. 5. CONTRACTORS INFORMATION ...................................... Indicate the State of Florida (if applicable) and St, Lucie County contractor's registration numbers, and the name of the business doing the work. 6. VALUE OF CONSTRUCTION: .........::.-............................. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the buildmg/constmation activity. The value of construction is used to determine the amount of permitting fees to be assessed St Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of constriction. All applications for Permits are to be submitted to the St Lucie County Building and Zoning Department;- St Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for Permits must be completed and filed with the Department no later than 4:30 P.M each business day. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please contact the St Lucie County Building and Zoning Department, at (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Following the issuance of this Windows, Skylights, Doors & Overhead doors replacement Permit, the scheduling of all required inspections may be made by calling (772) 462-1261. SLCCDV FORM NO: 006-05 Revised 4/10/2012 PDSD JC r�r���ri�ril� Product Approval Menu > Product or Application Search > Application List > Application Detail ';—Ib jD 40VY FL # FL16173 Application Type New Code Version 2010 Application Status Approved *Approved by DBPR. Approvals by DBPR shall t)e reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Trulite Window & Door Solutions, LLC Address/Phone/Email 8130 NW 74th Ave Medley, FL 33166 (305) 887-2646 rperez@awpllc.com Authorized Signature Javad Ahmad alfarooq@afceng.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency Miami -Dade BCCO - CER Validated By Miami -Dade BCCO - VAL Referenced Standard and Year (of Standard) Standard Year TAS 202-94 1994 Equivalence of Product Standards Certified By http://www.floridabuilding.org/pr/pr app_Oti.aspx?param=wGEVXQwtbgvyf4ngAXh10wRS5e%2fnK784D... ?/10/2014 Florida Building Code Online Product Approval Method Method 1 Option A Page 2 of 2 Date Submitted Date Validated Date Pending FBC Approval Date Approved 01/22/2013 02/08/2013 02/ 12/2013 Summary of Products FL # IlModell, Number or Name Description 16173.1 __] Series "580" Aluminum Single Non Impact Resistant Single Hung Window with Hung Window IMonolithic Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL16173 RO C CAC 580 Single Hung Wdw LMI (12- 0906.06).odf Approved for use outside HVHZ: Yes Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +60/-210 11/14/2017 Other: See attached Limitations Of Use for installation Installation Instructions instructions FL16173 RO II 580 Single Hung Wdw LMI (12- 0906.06).odf FL16173 RO II Limitations Of Use.Ddf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® 99 M C[ £CICt970E http://www.floridabuilding.org/pr/pr app_Oti.aspx?param=wSEVXQwtDgvyf4ngAXhlOwRS5e%2fnK7840... 2/10/2014 M IAM I•DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv Trulite Window & Door Solutions, LLC 8130 NW 74n' Avenue Medley, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Pmduct Corns:;:,': Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series 11580" Aluminum Single Hung Window — N.I. APPROVAL DOCUMENT: Drawing No. W96-38, titled "Series 580 Alum Single Hung Window (N.I.)" Sheets 1 through 5 of 5, dated 10/10/96 with revision H dated 12/23/11, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahrnad,.P.E., bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: None. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, .-1orida, a d followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA# 12-0118.16 and consists of this page 1 and evidence pages 'E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 12-0906.06 Expiration Date: November 14, 2017 Approval Date: December 06, 2012 Page 1 I Trulite Window & Door Solutions, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. W96-38, titled "Series 580 Alum Single Hung Window (N.I.)" Sheets i through 5 of 5, dated 10/10/96 with revision H dated 12/23/10, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per ASTM 588, TAS 202-94 along with marked -up drawings and installation diagram of a series 580 eyebrow top aluminum single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-5343, dated 10/09/07, signed and sealed by Carlos S. Rionda, P.E. (Submitted under NOA#09-0316.10) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per ASTM 588, TAS 202-94 along with marked -up drawings and installation diagram of a series 580 radius top aluminum single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-4443, dated 01/26/05, signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA #09-0316. 10) 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per AAMA 1302.paragraph 5 3.1.1 to 3.1.5 along with marked -up drawings and installation diagram of a series 580 aluminum single hung window, glazed w/ 3/16" temp. glass, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-3879, dated 08/28/03, signed and sealed by Joseph Chan, P.E. (Submitted under NOA #02-0507.06) 4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Water Resistance Test, per FBC, TAS 202-94 along with marked -up drawings and installation diagram of a Series 580 Aluminum Single Hung Window, glazed with 1 /8" ann. glass, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-3861, dated 08/07/03, signed and sealed by Joseph Chan, P.E. (Submitted under NOA #02-0507.06) Manuel Per , Product Control Ex toner NOA No. 12-0906.6C, Expiration Date: November 14, 2017 Approval Date: December 06, 2012 E-1 Trulite Window & Door Solutions, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-2007 and FBC-2010, dated 02/24/09 and updated on 01/04/12, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under previous NOA #12-0118.16) 2. Glazing complies with ASTM E1300-04 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of conformance, complying with the FBC-2010, and of no financial interest, dated January 4, 2012, signed and sealed by Javad Ahmad, P.E. (Submitted underprevious'NOA #12-0118.16) G. OTHERS 1. Notice of Acceptance No. 12-0118.16, issued to Trulite Window & Door Solutions, LLC, for their Series "580" Aluminum Single Hung Window — N.I., approved on 03/15/12 and expiring on 11/14/12. I jae6Q) Manuel Per .E. Product Control xam' er NOA No. 12- 6.06 Expiration Date: November 14, 2017 Approval Date: December 06, 2012 E-2 SERIES 580 ALUMINUM SINGLE BUNG WINDO DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHART SHOWN ON SHEET 2. APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF S.H./S.H. OR S.H. WITH OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING MIAMI—DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOW OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. REQUIREMENTS H HE OF THE FLORIDA BUILDING CODE INCLUDINGLHIGVH VELOCITY HURRICANE ZONE (HVHZ). WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS, ANCHORS EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO, ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL. A LOAD DURATION INCREAs' IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY.; MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF. THE FLORIDA BLDG. CODE SECTION 2003.8.4. 53 1/8' 53 WINDOW/8. WIDTH WINDOW WIDTH ji!ll m I 50 1/8" 50 1/8" TOP CORNERS OF D.L. OPG. (FIXED)D.L OPO. (RXEO ARCH TOP WDWS. TO ECURED 13 5 8' ) BBYSSCREWS 13 5/8" OR SPOT WELDINGFALSE PPLIE) MAX. �•OsURFMAY BEP SED 8 MAX. A8" MAX. HEADCORNERS HEno CORNERS 0 �7 r II li 11 II 0 d Q Q I� (n u u II III � = v oo II II M — n N, _-----II—--j--_—__ M J II II X N z co �p n 48 1 /2' 48 1/2- U.L. OPG. D.L.OPO. U y 50 11/18° 50 11/16" m W VENT WIDTH VENT WIDTH DD M O TYPICAL ELEVATION TESTED UNITS )RODUCPRENEM o M a 6.plylnaerkhthe Fb*6618: R Ralding Code -0 0 ) / C 4aepteace No a�2S EnPirellon Mte Dr = Mia ePrBddd. ' MONOLITHIC GLASS _ NON IMPACT o Engr, JA AD AHMAD d Q c CML, ,P•RODUCFRBVISBD 5J FLAP. —2 ea complyingwlehehaFlodda . P. 836. 13tti1diugCade u�•, Accept9nceNo a 3 INSTALLATION .Of YAS PRODUCT IN THE HVHZ AREA REQUIRES THE Br ifetionl)ffio .D12 M USE OF APPROVED ,NUTTERS OR EXTERNAL PROTECTION DEVICES - By drawing no. COMPLYING WITH 1{WTZ REQUIREMENTS, 2012 U y n0I2 INSTALLATION OF *S SYSTEM OUTSIDE THE HVHZ AREA SHALL MEET °� 1 F W96-38 THE APPLICABLE RrQUI.REMENTS FOR WIND BORNE DEBRIS PROTECTION. DESIGN LOAD CAPACITY - PSF WINDOW DIMS. 1/8" ANN. GLASS 3/LB" ANN. GLASS 3/16' TEMP. GLAS ANCHORS METHOD 'A' ANCHORS METHOD '6' ANCHORS METHOD 'A' ANCHORS METHOD 'B' ANCHORS METHOD '8' WIDTH HEIGHT 1NT.(-) EXL(+) 1M.(-) EXT.(+) 1NT.(-) EXT.(+) 1NL(-) EXT.(+) 1NT.(-) 19-1/8" 26-1/2" 37" 42' 48' 53-1/B' 26" (3) 80.0 60.0 80.0 60.0 121.6 6G.O 125.0 60.0 - 210.0 80.0 60.0 80.0 60.0 87.4 60.0 126.0 60.0 179.7 P48.6 54.0 60.0 80.0 54.0 54.9 60.0 112.9 60.0 112.9 48.8 60.079.3 46.8 46.6 60.0 95.9 60.0 95.0 39.5 52.7 52.7 39.5 39.5 60.0 81.3 60.0 81.3 34,9 38.6 38.6 34.9 34.9 60.0 71.9 60.0 71.9 19-1/8' 28-1/2' 37" 42' 48" 53-1/8^ 38-3/8' (4) 60.0 80.0 60.0 80.0 00-0 109.9 00.0 125.0 60.0 210.0 00.0 79.3 60.0 80.0 00.0 79.3 60.0 125.0 60.0 163.1 88.6 56.8 60.0 75.6 58.8 56.B 60.0 116.8 - 6O.D 116.8 50.0 50.0 56.3 56.3 SO 50.0 60.0 102.9 60.0 102.9 37.0 37.0 37.0 37.0 43.8 43.8 00.0 90.1 60.0 90.1 - - -To -a - J9.5 39.6 60.0 '81.4 6D.0 81.4 19-1/6" 26-1/2" 37' 42" 1. 50-5/9" (4) 80.0 60.0 80.0 60.0 03.3 60.0 125.0 60.0 171.3 80.1 80.1 B0.0 SO.D BOX 80.1 60.0 123.7 60.0 123.7 43.1 43.1 60.0 64.6 43.1 43.1 60.0 88.6 60.0 80.6 - - - 37.9 37.9 60.0 78.0 60.0 78.0 - - - 33.2 33.2 80.0 65.3 80.0 68.3 30.0 J0.0 80.0 ;81.7 50.0 61.7 19-1/8" 26-1/2" 37' 42" 4W 53-1/8' 59 (5) 110.0 80.0 60.0 11 8D.0 60.0 89.3 60.0 125.0 60.0 183.8 60.0 64,8 8% 80.0 60,0 84.5 50.0 125.0 60.0 132.8 48.2 48.2 47.9 47.9 46.2 46.2 60.0 95.0 60.0 95.0 - - - - 40.7 40.7 60.0 93.7 80.0 83.7 - - - - 35.8 35.6 60.0 1 73.2 60.0 1 73.2 - - - - 32.2 32.2 00.0 64.0 60.0 66.2 19-1/6' 26-1/2" 37' 42° 48" 63" (e) 60.0 80.0 6090 80.0 60.0 100.4 60.0 126.0 60.0 208.6 60.0 72.5 60.0 78.7 80.0 72.5 60.0 125.0 60.0 149.0 47.0 47.0 47.0 47.0 51.9 51.9 60.0 97.5 60.0 106.7 - - - - 45.7 45.7 60.0 85.1 60.0 93.1 60.0 71.9 60.0 75.8 1 60.0 827 1 60.0 65.4 19-1/8" ZB-1/2" 37" 42" 46" 53-1/8' 74-1/4' (0) 60.0 74.6 60.0 74.6 60.0 85.2 60.0 125.0 80.0 175.2 60.0 61.5 60.0 64.1 60.0 61.5 60.0 113.4 60.0 1 126.5 - - - - 44.0 44.0 60.0 92.0 60.0 1 90.8 - - - - 39.8 33.8 00.0 74.8 60.0 79.8 - -' - - 33.9 33.9 80.0 85.5 80.0 1 69.8 - - - - 30.7 30.7 58.0 68.0 80.0 80.0 - "U. IN rMLNn1G515 INUIUAIE NO. OF ANCHORS PER JAMB. 1 4' DIA. ANCHORS AT THIS LOCATIDN JAMBS FOR UPPER & LOWER HALF OF JAMBS JAMBS ANCHORS METHOD 'A' ANCHORS METHOD 'B' 7A�LE pg NDOW WID WINDOW WID WINDOW WIO WINDOW WIDTH APPROVED CONFIGURATIONS SHAPES SHOWN ABOVE OR SIMILAR 1/6" ANN. GLASS OR CLASS GLASS )NE CS 1000 .)ILODUCTRENEWED as c6mplytng with the Florid:. GLAZING OPTIONS 981dhig code - Accepteere .14-0 to Fic im0oo Dote By NOTE: Miami ePr6daet Coley GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-04 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-�219 Fn0rp JAV P AHMAD -1PROUILIMItEVISIM CIVIL FLA. PE pp 705g2 r9 COTIVIy1og with the FWd6 C.A.N.I'J536 Inthdip8 Code _.. _ or -owing no. W96-38 TYPICAL ANCHORS 1/4" TAPCONS SEE 0". FOR SPACING Ge CeJ. .d' d. a. •a,. O a w I u O 1 I N 14'OOD PUCK., ;a d I OPTIONAL TO BOTTOM LATCH 14 d NO AR:t'IORS;REQa: A1-SRL• SPACING TYPICAL ANCHORS #10 SMS SEE ELEV. FOR SPACING COUNTY APPROVED MULLION ANCHORS TE NOA TYPICAL ANCHORS 1/4" TAPCONS SEE ELEV, FOR SPACING WOOD BUCKS AND METAL STRUCTURE -NOT BY TRULITE MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS: SEE Emv. FOR SPACING 3/16" OR 1/4" TAPCONS (SEE SHEET 2 FOR USE OF 3/16" TAPCONS) INTO 2BY WOOD BUCKS OR WOOD STRUCTURE 1-3/8" MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO GONG. OR MASONRY 1-1/4" MIN. EMBED INTO CONC. OR MASONRY DIRECTLY INTO CONC. OR MASONRY 1-1/4" MIN. EMBED INTO CONC. OR MASONRY #12 SMS OR SELF DRILLING SCREWS (GRADE 5 CR$1 INTO METAL STRUCTURES STEEL : 12 GA. MIN. (Fy = 36 KSI MIN.) ALUMINUM : 1/8" THK. MIN. (6063—T5 MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) 910 SMS OR SELF DRILLING SCREW'; INTO MIAMI—DADE COUNTY APPROVED MULLIONS (NO SHIM SPACE) ANCHOR EDGE DISTANCES INTO CONCRETE AND MASONRY = 1-1/4" MIN. INTO WOOD STRUCTURE = 3/4" MIN. INTO METAL STRUCTURE = 1/2" MIN. SEALANT: ALL LOWER FRAME AND VENT CORNERS, AND HEADS OF INSTALLATION SCREWS AT SILL TO BE SEALED WITH ALUMINUM COLORED SEALANT, SCHNEE MOREHEAD 5504 OR EQUIV. PADS: ONE 1/4" X 3/4" ADHESIVE CLOSED CELL FOAM PAD AT EACH END OF FIXED MTG. RAIL. TNEEPHOLES: W1 = 3/4" WEEP NOTCH AT EACH END iRODUCT ae cumplytns theIR01 quid ingcode . Am is No G a s ox Inlion Dare qd c BY �awaux Mfn P El- dATD AWD PP.ODUCI•R6VISED d OMpL aswmplyingwithFLAOteFhA1� C.AN 'J538S92 Didldfng ludo a AcceprenGo No ,p fix Imt[On DnIO /2 .y £ r--� Miam1 c{ drawing no. `JAN' 2012 W96-38 MANF./BUPPLIBR/RBMARXS 1 YE-169 1 FRAME HEAD 8083-T8 - 2 YE-167 1 FRAME SILL 8063-T6 - 3 YE-102 2 FRAME JAMB 8063-TB - 4 YE-162 1 FIXED RAIL 8083-T6 - 6 YE-151 1 VENT TOP RAIL 8063-Te - 8 YE-188 1 VENT BOTTOM RAIL 6083-TB - 7 YE-92D 2 VENT JAMB 8083-T5 - 8 - AS READ. GLAZING BEAD ALUMINUM ROLL FORMED 10 - 2/ VENT BLOCK &TACKLE BALANCE - - 11 YH-511 AS READ. BULB VINYL PVC SINGLE 12 YH-810 AS REOD. BULB VINYL PVC SINGLE 13 YH-S09F AS READ, PILE-SCHLEOEL .107 X 2G0 - FIN SEAL (DOUBLE) 14 YH-504 2/ VENT VENT LATCHES NYLON/CELCON AT 8" FROM ENDS 14A YH-919 2/ VENT CAM LOCKS ZAMAK AT 8" FROM ENDS 15 �10 X 3/4" 8 FRAME ASSEMBLY SCREWS CRS PLATED, PH SMS 18 BB X 1" 2 FIXED RAIL SCREWS CRS CAD PLATED, PH SMS 17 jJ8 X 1-1/4" 4/ VENT VENT ASSEMBLY SCREWS CRS CAD PLATED, PH SMS m m 3 Z W Zd w LL a O 0. �8 G n o , a QQ TYPICAL ANCHORS Q 6 MIAMI-DADE COUNTY (i10 SMS 0 "� CO C APPROVED MULLION SEE ELEV. FOR SPACING yq 3 u a SEE SEPARATE NOA j �i N a� O v z � o .. _.. _.._..-.._.._.. .. _.. _.. _..-.._.._.. U' ro _ M TYPICAL ANCHORS WINDOW WIDTH WINDOW WIDTH SEE ELEV. FOR SPACING r n SEE SHEET 2 FOR CAPACITY 3 1BY Z ,n WOOD BUCKS TYPICAL ANCHORS o 3/1B" MAX, O 1/4' SHIM SEE ELEV. FOR SPACING M SHIM MAX.SEE SHEET 2 FOR CAPACITY pD VENT WIDTH 13 7 D.L. 'OPG. 10 ., 1/4' SHIM METAL MAX, yCK STRUCTUREURE p�*�.�1. 9aidingCods.4tteptantt Na Q �rE i.anoo Date I/ B EXTERIOR Y+ 's Miami ade:PhWd m 3!• TYPICAL ANCHORS o D.L. OPG. E4EV. FOR SPACING o0 SEE S EET 2 FOR CAPACITY VINDDW, WIDTH Engr. JACML� 'ro PRODUCT REVISED FLA. PE yy ZO0 92' OComplyingwithlheFlorlda d CAgI. 3518 Building Cod* ' r �. A *e No SEE ELEV. NFOR SPACING *p ion Date /Q SEE SHEET 2 FOR CAPACITY BY —hewn /d* la ell drawing no. IV 12012 W96-38 sheet 4of 5 ITEM ® PART RRQD. DESCRIPTION MATERIAL �— 2.220 .BBt 9 •055 1.327 .827 .860 �»- FRAME HEAD 812 -�1 .052 .88i 1 1.437 i—I—t.os2 FIXED RAIL .988 1.1 055 II1.625 .812 f� VENT TOP RAIL VENT BOTTOM FRAME SILL 1.125 1.07 ..055 .812 .087 VENT SIDE RAIL .93o I-- F1.055� 2 2.104 4 .812 1.179�•i 1,817 FRAME JAMB 3/4' WEEP AT EACH SCREEN REFAINI 17 U� Z f� o � o m� 09 a— g ti vCfRR Oaao 00,°2q: 17 � z 35 a s ¢ rC M g oo M S.H. VENT CORNER DETAIL 3 MDtcrRMWW® a+cunpylegwhrt6eltoffiy = 9�Wiea Code m - i,. t1,ue 17 y ° - D m.gwLLo= y O • Mla i Eeae JAVAD AHMAD .PRODUCT REVISED 'A • BwdeFLA. PE87Ctl CAN. iodPg d , Aimpime No etc' IImDeto 12C. ` t DyC tvy I Fm drawing no. 1112Qi2 W96-38 sheet 5of 5 R Property Appraiser - St.Lucie County, FL Page 1 of 1 Sherry L Johnson -Eason Record: 1 of 1 Property Identification Site Address: 2809 JEFFERSON PKWY Sec/Town/Range: 29:34S :40E Map ID: 14/29S Zoning: IL Ownership and Mailing Owner: Sherry L Johnson -Eason Address: 1414 NW 41st St Miami FL 33142 Sales Information Date Price Code 1/28/2014 35900 0112 7/9/2013 0 0112 4/27/2001 58000 00 12/29/1993 42500 00 9/28/1993 100 01 10/22/1992 100 01 5/1 /1987 0 01 5/1 /1987 51700 01 Deed SP CT WD WD QC QC CV CV PROPERTY RECORD CARD <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print 00 ParcelID: 1428-702-1323-000-9 �����CIE- Account#: 9996 tiTtr._.. Use Type: M-F < 10U City/Cnty: Saint Lucie County Legal Description SAN LUCIE PLAZA S/D-UNIT ONE- BLK 59 N 40 FT OF E 1/2 OF LOT 3AND N 40 FT OF LOTS 4 AND 5 AND S 40 F More... Assessment 2013 Total Land and Building Book/Page 2013 Final: 32600 Land Value: 3800 Acres: 0.24 3602 / 0383 Assessed: 32600 Building Value: 28800 3537 / 1015 Ag.Credit: 0 Finished Area: 2400 SgFt 1389 / 2609 Exempt: 0878 / 1450 Taxable: 0864 / 2664 Taxes: 660.21 0812/1722 0554/2011 0543 / 0712 BUILDING INFORMATION Exterior Features View: - RoofCover: ExtType: MFH - M.F. LOW RIS YearBlt: Grade: D - D EffYrBlt: StoryHght: 0010 -1 Story No.Units: Interior Features SA - Asph Shingle RoofStruct: GA - Gable 1977 Frame: - 1965 PrimeWall: BP - Conc Block 2 SecWall: - BedRooms: 1 Electric: AV - AVERAGE PrmintWall: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHt/Fl: STD 1 /2Bath: 0 HeatFuel: ELEC - Electric Prm.Flors: CA - A TUCON %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Use Type Type Measure Depth 1 0800-M-F < 10U 225 -Front Ft 80 132 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED http://www.paslc.org/paslc/prc.asp?prelid=142870213230009 2/11/2014