Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE US ONLY ) Date: a LD- ee Due: Receipt# Permit # Q r 1 PLANNING & DEVELOPMENT SERVICES �s Otlz BUILDING& CODE REGULATION DIVISION SC,l VI 2300 Virginia Avenue �N"� — ";{ Ft. Pierce, FL 34982-5652 8t 772-462-1553 C/o C, ounty. APPLICATION FOR ALUMINUM STRUCTURES PERMIT ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED PROJECT INFORMATION I . LOCATION/SITE ADDRESS:-?- o1 ,--Zpp -- --con l icp� Q ��- `Q ✓', ; �� Ij(AR75\ 2. PROJECT NAME&r-1-e,\ �C SITE PLAN NAME: 3. PROPERTY TAX ID #: ����{ `.a 8G1�"Z QU' •(-.p 4. LEGAL DESCRIPTION (attach extra sheets if necessary):�/S�'/� `O. ✓� jry�p��wQpp� 5. PLAT BK_1 2� PAGE --� !S71— BLOCK LOT L�S 6. PARCEL SIZE: ACRES/SQ F J LOT DIMENSIONS - U r x 7. SETBACKS (ACTUAL) FRONT: -lQ BACK: �3.� RIGHT SIDE: ��1,� LEFT SIDE: 8. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N = New A = Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION i SCREEN ROOM NEW ❑ EXISTING X ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ CAT 1, 2 OR 3 SUNROOM ❑ NEW ❑ EXISTING X ❑ ALUMINUM COMP. SHED ❑ NEW ❑ EXISTING X ❑ POOL ENCLOSURE ❑ NEW ❑ EXISTING X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X OTHER:Ak NEW EXISTING (X ❑ ALUM POOL FENCE "6 Li ear feet TOTAL SQUARE FOOTAGE OF CONSTRUCTION 9. VALUE OF CONSTRUCTION: $ --) O . The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev.04/26/2010 OWNER INFORMATION ^1 -�Ielk Ci.,�YI � O- NAME: C) Q ADDR Z ��• 1 CITY: ''C PAC STATE: r Z_ ZIP �c1 q �!;— 1 PHONE (DAYTIME): () EMAIL: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: c ST. LUCIE COUNTY CERT #: ce BUSINESS NAME: QUALIFIER'S NAME: C 01n ✓� ADD SS-: \ 'r• ` , CITY: STATE: �C_ ZIP s 'C, S 1 PHONE (DAYTIME): (17 5•(a7772. FAX NO. Zemail: pTC'�'1 ARCHITECT/ENGINEER: k� ADDRESS: CITY: Cl e arvo STATE: r L ZIP-S1S-?CQCD PHONE (DAYTIME): NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) OFFICE USE ONLY SECTION TOWNSHIP RANGE MAP NO. Additional ZONING LAND USE LOT CVG % Permits Required REPORT L�3lf BIMS FEE $ MISC FEES $ TOTAL FEES $ CODE I BUILDING & ZONING REVIEW FRONT PLANS VALUE OF CONSTRUCTION REVIEW COUNTER ZONING SUPERVISOR EXAMINER VEGETATION USING ICC TABLE DATE COMPLETE a i3 rq 0. lye INITIALS 0200" J ` II CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not exceed the footprint of the structure that was in existence prior to removal by the storms. (!�O A '.'�IA-- O E O CONTRACTOR SIGNATURE CON CTOR SIGNATURE S ATE OF FL A / \ a 1� o ATE OF FL q \ i COUNTY OF r L� '� _ UNTY OF q- llJl� : l! c The foregoing instrum nt was acknowledged before me %;•,,'�`' . a foregoing instrument was acknowledged before me E �a me this day of , 205 e this --_7 day of 0 , Y ` _ Crr r y. y. I who is personally known �o me, or who has T y a o is personally known ✓ to me, or who has T G to C T , N produced m :N .T oduced CD r w hi= O= (O r G N as i tification. Im identification. �eal) a ignature of No ignature ofN IMPORTANT NOTICES: • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNERBUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/BLDR AFFIDAVIT. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3924402 OR BO< )503 PAGE 1381, Recorded 02/12/2014 , °'1:37 AM J NOTICE OF COMMENCEMENT To be completed when construction value exceeds $2,500,00 �p PERMIT#: / yC,� -i�/ TAXFOLIO# 1 `-�� L�Q �OOZ •VW.\O STATE OF FLORIDA COUNTY OF The undersigned hereby gives notice that Improvement Will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following Information is provided in this Notice of Commencement GAI, DES RIPTION QF PROPERTY (AND 57REET ADDRESS, IF AVAILAB YI'�a�=� a�.�v� C�n,� GENERAL DESCRIPTION OF IMPROVEMENT: QC4% CONTRACTOR'S NAME: THE PORCH FACTORY LLC Phone No.:772465-6772 Address: 7356 Commercial Cirde Unit 40 Ft Pierce FL 34951 SURETY COMPANY (If applicable, a copy of the payment bond is attached): Name and Address: Phone No.: Bond amount LENDER'S NAME: Phone Persons within the State of Florida designated by owner upon whom notices or other documents may be served as provided by Section 713.13 (1) (a) 7, Florida Statutes: Phone In addition to himself or herself, ownerdesignales of to receive a copy of the Lienors Notice as provided in Section 713.13 (1) (b), Florida Stautes. Phone number of person or entity designated by Owner. Expiration date of Notice of Commencement (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date Is specked): I declare that I hate- ad the foregoing and that the facts In it are true to the best of my knowledge and belief. Signatory's TttlelOfffce The foregoing instrument was acknowledged before me this I day ofr� 20 m lK1kY1(�a0, 1 -- Name of Person n Type of authority (e.g. officer, truslee) Party on (Print, Type, or Stamp Commissioned Name of Notary) T:19LDOIdg_FomislNew ApplicationsWormskNotice of CommencementDocx Of whom instrument was executed. Personally known ❑ or produced Identifi Ion 3--� Type of idenfiration produced F:,:•:':`° dERALYf1NE A SELt Notuy Public • Still Florida ' � C"",19111" JW tt, totE 'w, CWah1tob I FF OSjM STATE aF FLORIDA ST. LUCIE COUNTY THIS IS TO CERTIFY THATTHiSISATe,f5ttr�f.f TRUE AND CORRECT COPY Of THE ,-_t� ` ORIGINAL. h //= UCIR Dr e: v,TCD - 2 99.67 O„ 6 - oA �b 99.70 C� Z 5 I'D PCP 99.97� 9.9a3613Op LB#2391 OR�� 100.01 E Vv 6 /v$y2yQ 100.17 / 0 / PROJECT BENCHMARK _3 9 Q 0Q Q� p 99.83 �t ELEVATION = 100.0 o I ASSUMED 99.99 IRC. ; R _ LB �� 6 V ,�j + 2 %k�� ATER METERS 100.13 L=81.01'P _i,9.85 D 9� y�9 10JPUE 100.10 L=65.50 1 4x4 CM — ID /5 IRC _ LS #2391 L8 14286 w 4 6' 0.12'N 0.3'S o B LIMITS OF PLAT 101.39 x EAST LINE 19.3' 0.7' ;o 2.0' r M MIN, SETBACK REQ, - '00 _ ..�„ N 5 LOT 44 FRONT °° °JAY x VACANT SIDES % 43'',�� as x 101.65 0 CNR 54�e,�A�A1 w co a o E7 cv ;n REAR O PROPOSED p :n 1 STY RESIDENCE ci7 ZNG. �LLp OccD:) F.F. = 102.0 TECH. Z x 101.61 r1610YA "J '�' PORCH M 100.99 0 18.3' I'D #5 IRC ID g5 IRC 100.52 LOT 45 LB #4286 LB #4286 "? ID 5 IRC 7.06'S,0.03'W 0.02'S,0.01'E LB #4286 0.02'S,0.01'E 10' PUdcDE — — 99.68 —� 65.00'P °•H'U. O.H.U. / 99.96 75.00'P i N89'09'18"W 65.00P 99.95 FD FD (5 IRC i IRCJ ' LB /2391 LB 02391 0.02'N,5.06'E 0.04'N,9.96'W NOT PLATTED SIDSS��a CNR. SID RR i ZONINGI TECH. y Search Results for Map Page 1 of 1 Hoene About This Site Lat/Long Finder Related Resources Sponsors About ATC Contact Search Results Latitude: 27.4806 Longitude:-80.4253 ASCE 7-10 Wind Speeds (3-sec peak gust MPH*): Risk Category I: 144 Risk Category II: 156 Risk Category III -IV: 167 MRI** 10 Year: 87 MRI** 25 Year: 105 MRI** 50 Year: 118 MRI** 100 Year: 129 ASCE 7-05: 135 ASCE 7-93: 99 •MPH(Miles per hour) ••MRI Mean Recurrence Interval (years) Users should consult with local building officials to determine if there are community -specific wind speed requirements that govern. Download a PDF of your results Print your results WIND SPEED WEB SITE DISCLAIMER: While the information presented on this web site is believed to be correct, ATC assumes no responsibility or liability for its accuracy. The material presented in the wind speed report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the wind speed report provided by this web site. Users of the information from this web site assume all liability arising from such use. Use of the output of this web site does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site(s) described by latitude/longitude location in the wind speed report. Sponsored by the ATC Endowment Fund • Applied Technology Council - 201 Redwood Shores Parkway, Suite 240 • Redwood City, Califomia 94065 • (650) 595-1542 http://www. atcouncil.org/windspeed/index.php?option=com_content&view=article&id=10... 2/3/2014 #w1-7 .'.in.. .J + -•� l r t• 1 tic Y a .. �y ��. a"� ,�r �' '"s• �t a �"'` `#` 1�' S* '� i F �Z h � r � z `s b .,� y,5.. � , � � .:z d f-..: � f "dun.}`•ar day ' � d .� �` y.'w'R{ ".k� /� } fi'� Y ..,wf�N"k•q'. ''�`� t.. F z��� ���HY� � 'M'*a� y^ '. M x t# ��: I 1W. �Ct w.S'^•, ° rp, ''* 4 b$ sib i eft 2692 Co%lfebi�f er� , kFL 374 1 r rpot s ;� z k 44 ti• sA ° �w. .'%*."`!,. >�'La.,y� r^, S ;xMx. .}. �.` ,.a�'.. *+,.`+tl.:`0�'"�-�`v��' 'z r. � ' ;s� �''°� r ".^.iz ;;`'y � �i. !';. •, y�,..�,w,t„�,,;�,�::, �,,`r .�;r .�` c � n.,'. F ,4.� . f$�. pR,:t �.d, t..., �R 5 " `a•,. �. ,y�. � �' - � �o a CONTRACTOR: THE PORCH _ . 'CTORY DESIGN CRITERIA: Applicable Codes, Regulations, and Standards 1. The 2010 Florida Building Code. specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2005 Edition 3. ASCE 7-1 O. Wind Loads 1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category 1. 2. Basic Wind Speed, Table 1609C, State of Florida Debris Region & Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: VuLT =150 MPH, VASD =116 MPH 3. Exposure Category, Paragraph 1609.4.3: Exposure B 4. Building Category for Aluminum Structures, Paragraph 2002.6: Building Category 1- Screen Room : Non -Habitable, Unconditioned Foundation Design Existing concrete slab. No additional concrete footing or slab is required to resist the loads imposed upon the existing slab by the proposed construction if the existing slab is a minimum of 4" thick and in sound condition, free from structural cracking, spalling, or other deterioration. Roof Type 1. Roof Type: EXISTING 2. Roof Material: EXISTING Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the Florida Building Code, 2010 Edition, and any other applicable local codes and regulations. 2• The minimum wall thickness of aluminum extrusions shall be in accordance with the Florida Building Code, 2010 Edition and the 2005 Edition of the Aluminum Association Manual, but not less than 0.040 inches. 3. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Suncoast Architecture & Engineering, LLC. 4. Screen Material: Design based on 18/14 or 20/20 Better View. Any other material must be approved 5. Fasteners are required to be SAE Grade 5 or better zinc plated. 6. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or #12 screws 6" from ends and 12" center to center. 7. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type 1,- ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining+/- 1% - ASTM C 260 iv. Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing,Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after batching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 8. The minimum nominal thickness of protector panels (kickplates) shall be an industry standard of 0.024 inches. 9. All flashing and weatherproofing shall be provided by the contractor. WIND SPEEi_v ,..'fD EXPOSURE HAVE BEEN DETERMINED USING THE ADVANCED TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. 1- 00 d- 00 00 x r �I T. LUCIE COUNTY BUILDING DIVISION REVIEWED BY—` � DATE ` PLANS AND PEANT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE EXISTING `,COVERED PATIO,. �i r �\� 8'-5" 19'-10" 24" INSULATE[ KICKPLATE(TYP Z- Z. 77 O Y UJ Cr- =� U F-•� 0 CO `✓ oen^�Ceev,ee nJP'1'cew �... THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY DE NECESSARY Ifs ODDER TO COMPLY WITH ALL APPLICABLE CODES. W w W Z LU C7 �- W to Z O W O �" z 52 w N Z LL W Q 0 ac H 9 a. N LL W b U � J U�� W Z= _ Q ~ po H LU z to W ^�8 Q Z O N = F V1 In Z w o� N Chi N N LU DC t7 0 Q W W ellu w z W Oa n d W NOLL DRAWN BY EB DATE DRAWN 02105/14 REVISION SHEET NO: A-1 ALUMINUM MEMBERS DIMENSIONS (1) 1/2" CAP SCREW w/ NYLOCK JAM NUT - IN LIEU OF NYLOCK r i HOLLOW SECTIONS 1/e x 2"x r EXTRUDED JAM NUT, JAM NUT w/ (� • . 2 x 2: 2" x 2" x 0.046" ANGLE5052H32ALLOYEA I I THREADLOCKER MAY BE USED TIGHTEN THESE PLANS AND ALL PROPOSED I ORIS 2 x 3: 2" x 3" x 0.050" SIDE TOCOMACT-Do 2 x 4: 2" x 4" x 0.050" NOT OVERTIGHTEN ARE SUBJECT TO ANY CORRECTIONS w ��`" f< C31 LL • ' 2 x 5: 2" x 5" x 0.050" I 3" RECEIVING CHANNEL -� p I� a P .: ( D s �7 REQUIRED REQUIRE® BY FIELD INSPECTORS '1 HAT (D O OPEN BACK SECTIONS Ix3: 1"x2"x0.045" MAY BE NECESSARY IN ORDER TO %� � � �= I x 3: 1" x 3" x 0.045" v 4 Lu L.I.M.^I.. eNT � � 1fiPLY1MITHALLAPPLICABLEC®®ESa Rom{ O U) /Q/� V, j SNAP SECTIONS " 2 x 2 Snap: 2" x 2" x 0.045" t1 ✓ �, 2 x 3 Snap: 2" x 3" x 0.050" SLAB / FOOTING r '• 2 x 4 Snap: 2" x 4" x 0.045" SEE PLAN n UPRIGHT PROFE L i. - ' L EA' . SIONAL SEAL SELF MATING (SMB) SIDE VIEW OPTION 2: 2 x 4 SMB: 2" x 4" X 0.044" X 0.100" I x 1 x x 1 vs' 2 x 5 SMB: 2" X 5" x 0.050" x 0.100" OPTION 1: RECEIVING N RECEIVING CHANNEL C 2" x 2" x 1/8" ANGLE W/ W/ (3) #10 x 3/4" INTO � LLI 2 x 6 SMB: 2" x 6" x 0.050" x 0.120" (4) #10 x 5/8" EACH SIDE GIRT EACH FACE & (3) LLI 2 x 7 SMB: 2" x T' x 0.05T' x 0.120" (2) 3/8" DIA CONCRETE UPRIGHT 010 x 314" INTO UPRIGHT Z W 2 x 8 SNM: 2" x 8" x 0.072" x 0.124" SCREW ANCHORS I I 1" x 3" ALUM RECEIVING 2" x 7' OR 2" x a' I I (j d 2 x 9 SMB: 2" x 9" x 0.072" x 0.124" (21/4" CONC. EMBED) CHANNEL ANCHORED TO CHAIR RAIL MEMBER Z Q 2 x 10 SNM: 2" x 10" x 0.092" x 0.398" PAVERS W/ 1/4" x 21/4" W (J o CONCRETE SCREW ANCHOR _ _ _ _ _ _ _ _ _ I I Q MINIMUM FASTENER EDGE DISTANCE: 1/2" 24" O.C. MAX ZO MINIMUM FASTENER SPACING: 3/4" _ _ _ — i — _ _ = z CONCRETE SCREW ANCHOR: 4 GI'ar.,�'';'y;a.a Vic"' ..z ax ,1, `,' K. * s'+: ° >: i:t k: `1r ss4 '_ ' "" '?:.• U Vf Z 3 W W SIMPSON TITEN HD OR EQUIVALENT R 4 »•-` �x� >r • r LL ¢ SHEET METAL SCREWS (SMS): `' r i O W cc ITW / BUILDEX OR EQUIVALENT 4 ; I "Y=t 1"x 3" RECEIVING CHANNEL tr I-- O W/#12x3/4"SMS@1rO.C. LL 3" COMPOSITE�� WALL PANEL FRONT VIEW W B -x 3" OR LARGER SECTION POST TO CONCRETE DETAIL C GIRT TO POST DETAIL A-2 SCALE: NTS SCALE NTS A-2 W U H J o L) H � WOOD: #10 x 3" WOOD SCREWS, 6"IA— e a W z� N LJJ I-u m p m Q Z pc LL mm FROM GIRT&@17'O.C. CONC: LE z^ O a rn�mm w V u 1 1zi /4" x 3" TAPCONS, 6" FROM GIRT & @ 24" O.C. CONC. HEADER: WOOD HEADER: Z z u1 3 N N Q W o oc C 1/4" x 3" CONCRETE (1) 3/8" x 3" LAG SCREW INTO HEADER Vi 1"x 3" SCREWANCHOR 24" O.C. NCRETE HEADER: WOOD HEADER: EXISTING /8" DIA. x 3" CONCRETE SCREW 2" x r OR r X 3" HOLLOW #10 x 3" WOOD SCREWS HEADER CHOR INTO HEADER SECTION GIRT W/ (4) #10 x 1 @ 17' O.C. I 1/2" INTO SCREW BOSS 6EXISTING • • I 1 I W zb. x 3" x 0.040" ALUM RECEIVING 0 HANNEL W/ #10 x 3/4" SMS @ 24" O.C. EACH SIDE OF PANEL 1"x 3" HOLLOW SECTION 1" x 3" HOLLOW Ll'3"W/ #10 x r SMS - 6" Q W W wV SECTION EACH SIDE OF POST Z 3" COMPOSITE WOOD: #10 AND 24" O.C. MAX W W O FL Lf) -+ • �- ?i WALL PANEL x 3" WOOD SCREWS 1r O.C. -1 U rn O W r„a ck` s @ CONE r x 2' x 0.125" ALUM ANGLE W/ N m O j 1" x 3" ALUM RECEIVING 1/4" DIA x 3" CONCRETE (4) #14 x 3/4" SMS INTO UPRIGHT d W CV LL LL CHANNEL W/ #10 x 314" SMS SCREW ANCHOR @ 24" O.C. "fl DRAWN BY _ @ 24" O.C. EACH SIDE OF r x uPRIGHT PANEL 1" x 3" HOLLOW _ EB SECTION EXISTING HOST DATE DRAWN 02/05/14 C-, 1X3 TO HOST STRUCTURE DETAIL B�- B-2 REVISION A-2 SCALE: NTS 1X3 TO HEADER DETAIL POST TO HEADER DETAIL - Q A-2 SCALE: NTS A-2 SCALE: NTS ® - SHEET NO: A-2 I i a . r�,. o LL: O cn f+Pr„r PROFESSIUAl:6EAL a OC W W Z LJ J z Q a W c W a 0 z oW o �Z W V) z J LLJ yI�ll V- � O C O = THESE PLANS ANO ALL PROPOSED WORK � N s � ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO Lu o COMPLY WITH ALL APPLICABLE CODES, � � w 1/8" x 2" x 2" EXTRUDED ANGLE 5052 H-32 ALLOY a. ..5 2114'MIN CONC " SLAB / FOOTING a :.a ANCNON EMBEOMENIT SEE PLAN s' as ' ' K SIDE VIEW (1) 3/8" DIA. CONCRETE SCREWANCHORS (21/4" CONC. EMBED) LLI U U S ry w 1#14x 3/4"SMS W OR _ TO DJ N W t� m Q-X Z t" N F- to 0 x 3" RECEIVING- 1ANNEL c4 O V 6 n n z 3 Z z y 1 3 ry ry W OdaC a F N 06 DOORJAMB 1"x 3" RECEIVING CHANNEL a ANCHORED TO CONC W/ 1/4" .• ? ';� CONCRETE SCREWANCHOR a + v b•+ (MIN.11/4"EMBED)•a' 6" MAX EACH SIDE OF POST A AND 24" O.C. MAX FRONT VIEW DJ UPRIGHT TO CONCRETE PRE -HUNG A-3 DOOR LOCATION DETAIL SCALE:NTS N N a W Ir OC W af lz Q p cc w Q W f W O CL Q W c%j G. WNOLL DRAWN BY EB DATE DRAWN 02/05/14 REVISION SHEET NO: A-3