Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: I3144 FEES DUE: dd RECEIPT #: Permit #: Planning & Development Services Department 0 Building & Code Regulation Division SC,9� n/ 2300 Virginia Avenue j� - — Ft. Pierce, FL 34982-5652 Tel. 772-462-1553 4jC7@ C APPLICATION FOR ROOF PERMIT °4''/y SEE REVERSE SIDE FOR INSTRUCTIONS , 1. Location/Site Address: y3a 59 5E t�i4 0/2'14-. Pori S, _lade F 3Y9F� 2. Parcel ID Number: 3�((9-5-ye-Ol96--GV0-y Office Use ownship Range Map Page Zoning Land Use Initials Only 3. Description of Projector Work Activity: Re/uove t Re plolce 5&va% >mf otiku 4. Total Roof Area (square feet): YL90 5. Roof Pitch: T 6. Type of Roof: [ Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle / [ ] Tar & Gravel [ ] Modified Bitumen [ ] Other J✓ Product Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: NPA4 Pa rker Address: Y5`9 �� 6aVJ11 04ye_ City: N4 3^1.1&6e State: FL Zip: 31egF3 Phone: 77V-3Y3-3767 9. Value of Construction: $ g6 FL Reg/Cert #: tree 13a7r9 t County Cert #: ,LQu 4$50C14 S .=itX. Business Name: D JQJ } Fxeelgior Coif boo u, Cell Phone: -77a-5a8-/637 "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. fkeyi/U a. PRINT QUALIFIERS/OWNERSkSAME SIGNATUREfW QUAL IER/OWNER STATE OF FLORIDA, COUNTY OF 54. Lle C/e b �f ACKNOWLEDGED BEFORE ME THIS _ �3 DAY OF { \ 20 � , BY 11� Vy 1/� VY�q rTy ' �7 d1 SZi WHO IS PERSONALLY KNOWN E OR HAS PRODUCE M3 a " S 1b' IDENT ' =1?A t`�? Notary Public -State of Florida SIGNATURE OF NOTAItY TYPE OR PRINT NAME OF NGTARY ,. . iyY Comm. Expires Dec 16, 2016 a Commission # EE 858761 COMMISSION NUMBER �S11 G 1 Bonded Through National Notary Assn. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink only) or typed. This roof permit application is to be used only for those activities that are not otherwise included under a primary building permit. This application may not be used for any activity that includes structural alteration. Building activities involving structural alteration, in addition to the roof work, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. Location/Site Address 2. Parcel ID Number 3. Description of Project or Work Activity 4. Total Roof Area 5. Type of Roof 6. Owner Information 7. Contractor Information 8. Value of Construction Indicate the street address or general location of the property where the building activity is taking place. Indicate the tax identification number of the property where the building activity is taking place. Completely describe the building activity to take place. Please indicate if tear -off or shingle over shingle etc. Indicate total roof area to be affected by this permit. Also indicate the pitch of the roof, expressed as a standard ratio of run rise. Indicate the type of roof being repaired or resurfaced. Indicate the name and address of the owner of the property on which building activity is taking place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. Construction value is used to determine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. No applications will be accepted for processing'after 4:30 P.M. For assistance in completing this application, please call (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261. St. Lucie County Roof Permit Application rev. 3/1/2009 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # M 64- O `lj-i I, Keyl'N Q, MQiv ICaSZe/C licensed as a(n Contractor* ngineer/Architect (Please print name & circle license type) *FS468 Bui ing nspector *General, Building, Residential MRoofing Contractor any individual certified under 468 F.S. to make such an inspection. On or about -Q 1 1, I did personally inspect the roof deck nailing ( Date work at: TV 5E -12avdZa Qr e , Pori 51 (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) "6 aZ ccci-3a71g l Signat r and Seal License # STATE OF FLORIDA COUNTY OF J�, LGGGle Sworn to and subscribed before me this «+h day of rr� 20A by �e�'%a'%f% tvk'% ciry ' ►S2� 1.� , who is personally known to me or who has produced Q as identification. Notary Public, State o Florida Signature of Notary: Commission Number: G t��� -:� (Seal) En 01/19/2011 DEANNA GIVENS Notary Public - State of Florida = My Comm. Expires Dec 16, 2016 Commission # EE 858761 Bowed Through National Notary Assn Florida Building Code Online i Page 1 of 2 FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance. Method Testing Lab Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method FL2346-R4 Revision 2010 Approved Warrior Roofing Manufacturing 3050 Warrior Road Tuscaloosa, AL 35404 (205) 553-1734 ' Ext 115 Steven@WarriorRooflng.net Steven Crew Steven@WarriorRoofing.net Steven Crew 3050 Warrior Road Tuscaloosa, AL 35404 (205) 553-1734 Ext1024 Steven@WarriorRooflng.net Steven Crew 3050 Warrior Road Tuscaloosa, AL 35404 (205) 553-1734 Ext1024 Steven @ WarriorRoofing. net Roofing Underlayments Test Report PRI Construction Materials Technologies, LLC Keystone Certifications, Inc. 10/05/2019 Jesus Gonzalez, P.E. FZi Validation Checklist - Hardcopy Received FL2346 R4 COI PRI CMT Cert of Independence.odf Standard ASTM D226 ASTM D4869 Method 1 Option B Year 2006 2005 https://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtOc8bnSknRp... 2/ 12/2014 Florida Building Code Orl;ne Page 2 of 2;* Date Submitted Date Validated Date Pending FBC Approval Date Approved . Cummary of Drnriurfc 11/30/2011 12/05/2011 12/13/2011 01/31/2012 FL At Model, Number or Name Description 2346.1 #15 and #30 roofing felt ASTM D 226 Tested Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL2346 R4 II InstallationInstructions.odf Approved for use outside HVHZ: Yes Verified By: PRI Construction Materials Technologies, LLC Impact Resistant: N/A Test Reports Design Pressure: N/A FL2346 R4 TR 15A Test Reoort.odf Other: Primary roof covering should be installed FL2346 R4 TR 30A Test Reoort.Ddf immediately after felt. Roofing felt is not intended to be an unprotected weathering surface. 2346.2 15w and 30w roofing felt • ASTM D 4869 Tested Limits of Use Installation Instructions Approved for use in HVHZ: No FL2346 R4 II InstallationInstructions.odf Approved for use outside HVHZ: Yes Verified By: PRI Construction Materials Technologies, LLC Impact Resistant: N/A Test Reports Design Pressure: N/A FL2346 R4 TR 15w Test Reoort.odf Other: Primary roof covering should be installed FL2346 R4 TR 30w Test Reoort.DBf immediately after felt. Roofing felt is not intended to be an unprotected weathering surface. Back Next Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts:' , "cG`lac`"i M ' CfedilgxvEi https://www.floridabuilding.org/pr/pr 'app_dtl.aspx?param=wGEVXQwtDgtOcgbnSknRp... 2/12/2014 „ A. WARRIOR® ROOFING MANUFACTURING P.O. BOX40185 + TUSCALOOSA, AL 35404 *PHONE (205) 553-1734*FAX (205) 553.1755 . / .t. 193 LEROY ANDERSON ROAD + MONROE. GA 30655 * PHONE (770) 207-0695 + FAX (770) 207-0775 . 323 DEVELOPMENT AVENUE • CHAMBERSBURG, PA 17201 + PHONE (717) 709-0323 + FAX (717) 709-=7 Roofing Felt Installation Recommendations Be aware that roofing felt should not be walked upon prior to fastening into position. Proper safety equipment is recommended for all installations. Also, the roof decking should be clear of debris and moisture prior to installation of the roofing felt. Roofing felt should be installed from the bottom of the roof in horizontal layers to increase the water shedding ability of the felt. The initial layer of felt should be installed to cover the bottom edge of the decking, from edge to edge. Overhang is not required. Anchor the top corner of the felt after it has been properly positioned and roll.the felt out across the roof. Pay careful attention to roll the felt out smoothly, avoiding wrinkles as you move across the roof. The top edge of the felt should be fastened no less than every eight inches. 'The middle and bottom edge should also be fastened no less than every eight inches. Fasteners should be applied no less than every eight inches along the eaves. The next -course of felt should also .be aligned with the roof edge and should overlap the previous course two inches (sometimes referred to as head -lap). In the event you get to the end of a roll prior to getting to the opposite edge of the roof, begin a new roll with a four inch overlap over the end of the prior roll (sometimes referred to as end lap). The same fastening pattern used on the middle and bottom of the initial course should be used for each subsequent course. For the top of each subsequent course, fasten intermittently to hold the top edge in place until the next course is applied. The fasteners in the bottom of the next course will hold the top of the previous course securely. Continue up the roof in this manner. Be sure to firmly fasten the top of the final course if it terminates at the top edge of the roof. Otherwise, overlap the felt over the ridge and secure then begin at the bottom of the other side of the ridge and repeat the process. In valleys, lay a vertical section of roofing felt the length of the valley prior to the installation of the horizontal runs of roofing felt. If you use more than one section of roofing felt in a valley, be certain to start at the length a minimum of two inches as you move u] shedding. Wk; , , In the event some wrinkles are created while fastening down a course of felt, slice the wrinkles and fasten them flat to the deck. Then seal the cuts with waterproofing cement. Installation of the primary roof covering (ex. Shingles) is recommended immediately after felt installation. NOTE: LOCAL BUILDING CODES MAY REQUIRE A DIFFERENT FASTENING PATTERN AND/OR SPECIFIC FASTENER TYPES THAN RECOMMENDED BY THESE INSTRUCTIONS. PLEASE CONTACT YOUR LOCAL BUILDING CODE ADMINISTRATOR FOR THE EXISTENCE OF REGIONALLY SPECIFIC FASTENING REQUIREMENTS. Florida Building Code Online Page 1 of 2 FILE COPY Product Manufacturer GAF Address/Phone/Email 1361 Alps Road Wayne, NJ 07470 (973) 872-4421( lindareith@trinityerd.com Authorized Signature Beth McSorley lindareith@trinityerd.com Technical Representative Beth MCSorley Address/Phone/Email 1361 Alps Road - Bldg 11-1 Wayne, NJ 07470 (973) 872-44210 BMcSorley@gaf:com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from'a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy'Received Florida Engineer or Architect Name who developed the Robert Nieminen , Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/03/2014 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10124 R11 CQI Trinity ERD CI - Nieminen - 2013.odf Referenced Standard and Year (of Standard) Standard Year ASTM D3161 (Class F) 2006 ASTM D3462 2007 ASTM D7158 (Class H) 2007 TAS 107• 1995 Equivalence of Product Standards Certified -By Sections from the Code http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdMQNZ... 10/21 /2013 Florida Building Code 7,�' ine Page 2 of 2 r Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 08/29/2013 08/29/2013 09/08/2013 10/18/2013 Summary of Products FL tF IlModel, Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated, 5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10124 R11 II er0B2913FINAL GAF ASOhalt Shingles FL10124- R11. df Approved for use outside HVHZ: Yes Irhpact Resistant: N/A Verified By: Robert Nleminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10124 R11 AE er082913FINAL GAF Asphalt Shingles FL10124- RII.rdf Created by Independent Third Party: Yes m 'Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida, :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, mmact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395v. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: I�yw� eCirei_ -. SiCUfttYascYuK's" y'tr e http://floridabuilding.org/pr/pr_app_dtl.aspx?param-WGEVXQwtDquracBeVCbdMQNZ... 10/21 /2013 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT GAF 1361 Alps Road, Building 7-3 Wayne, NJ 07470 Evaluation Report 01506.01.08-1113 FL10124-RII Date of Issuance: 01/03/2008 Revision 13: 08/29/2013 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State. of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to.the product change. Acceptance of this Evaluation Re_ port by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA'ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 08/29/2013 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial. interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, . have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards'. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section "Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 . 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entity Examination Reference Date GAF (PDM 1915) Letter of Equivalency Seal -A -Ridge Impact Resistant IR O1/13/2012 PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL (TST 1740) ASTM D3462 93NK6295 11/29/1993 UL (TST 1740) ASTM D3462 99NK43835 01/12/2000 UL (TST 1740) TAS 107 94NK9632 03/29/2000 UL (TST 1740) ASTM D3462 OINK06632 02/02/2001 UL (TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001 UL (TST 1740) ASTM D3161 OINK37122 12/18/2001 UL (TST 1740) ASTM D3462 01NK37122 12/19/2001 UL (TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL (TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL (TST 1740) ASTM D3161 03CA5367 03/11/2003 UL (TST 1740) ASTM D3462 '03NK26444 10/17/2003 UL (TST 1740) ASTM D3462 04NK13850 06/07/2004 UL (TST 1740) ASTM D3161 04NK13850 06/23/2004 UL (TST 1740) ASTM D3161' 04NK30546 03/10/2005 UL (TST 1740) ASTM D3462 04NK22009 05/06/2005 UL (TST 1740) AS7M D3161 04NK22009 05/09/2005 UL (TST 1740). ASTM D3462 05NK27924 02/10/2006 UL (TST 1740) ASTM D3161 05NK27924 02/11/2006 UL (TST 1740) ASTM D3161,133462 06CA18077 06/05/2006 UL (TST 1740) -ASTM D3161,D3462 06CA16074 06/16/2006 UL (TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL (TST 1740) ASTM D3462 .06CA31603 12/01/2006 UL (TST 1740) ASTM D31.61,D3462 06CA41095 12/27/2006 UL (TST 1740) ASTM D3161 07NK05228 03/13/2007 UL (TST 1740) ASTM D3161 06CA31611 04/04/2007 UL (TST 1740) ASTM D3161 06CA61148 04/09/2007 UL (TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/2008 UL (TST 1740) ASTM D3161,D3462 07CA55908• 04/01/2008 UL (TST 1740) ASTM D3161,D'3462 09CA10592 03/26/2009 UL (TST 1740)' ASTM D3161,D3462 09CA06856 05/15/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09NK06647 08/01/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009 UL (TST 1740) ASTM D3161, D7158, D3462 1OCA35554 03/05/2010 UL (TST 1740) ASTM D3161, D7158, D3462 1OCA13686 05/15/2010 UL (TST 1740) ASTM D3462 IOCA07264 05/27/2010 UL (TST 1740) ASTM D3462 1OCA11953 10/29/2010 UL (TST 1740) ASTM D3161, D7158, D3462 IONK11951 10/30/2010 UL (TST 1740) ASTM D3161, D7158, 63462 1ONK12070 11/04/2010 UL (TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL (TST 1740) ASTM D3161, D7158, D3462 1OCA53934 03/33./2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011 UL (TST 1740) ASTM D3161, D7158, D3462 .11CA47919 12/03/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48408 12/08/2011 Exterior Research and Design, LLC. Evaluation Report'01506.01.08-R13 Certificate of Authorization #9503 FL10124-R11 Revision 13: 08/29/2013 Page 2 of 5 0 a. Entity Examination Reference Date UL(TST 1740) ASTM D3161, D7158, D3462 11CA48725 12/09/2011 UL'LLC. (TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,LLC. (TST 9628) ASTM D3161, D7158,. D3462 12CA58151 02/15/2013 UL,LLC. (TST 9628) ASTM D3161 12CA38083 02/26/2013 UL,LLC. (TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,LLC. (TST 9628). ASTM D3161 13CA37934 08/02/2013 UL, LLC. (QUA 9625) Quality Control Inspection Report, File No. R21 05/03/2013 4. PRODUCT DESCRIPTION: 4.1 Marquis WeatherMax, Royal Sovereign and Sentinel. are a fiberglass reinforced, 3-tab asphalt roof shingles. 4.2 Camelot, Camelot.II, Capstone, Country Mansion, Country Mansion II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Slate, Grand Slate II, Monaco, Sienna, Timberline American Harvest, Timberline ArmorShield II, Timberline Natural Shadow, Timberline Natural Shadow Arctic White, Timberline HD, Timberline Cool Series, Timberline Ultra HD and Woodland are fiberglass reinforced, laminated asphalt roof shingles. 4.3 Slateline is a fiberglass reinforced, 5-tab asphalt roof shingle. 4.4 Seal -A- Ridge, Seal -A -Ridge Armorshield, Seal -A -Ridge IR and Timbertex Hip and Ridge are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.5 Pro -Start. Starter Strip Shingles and WeatherBlocker Starter. Strip Shingles are a starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of.this Evaluation Repdrt; refer to current Approved Roofing Materials Directory for fire ratings.of this product. 5.3 Wind Class ificati o rr: 5.3.1 All GAF shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating: 5.3.2 All GAF hip & ridge shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM b3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasa = 150 mph (V„lt = 194 mph). * Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B Qr C and a -building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.01.08-R13 FL10124-R11 Revision 13: 08/29/2013 Page 3 of 5 .d �\J Ti INITY I ER® 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Starter Shingles: 6.2.1 Installation of Pro -Start Starter Strip Shingles and WeatherBlocker Starter Strip Shingles shall comply with the manufacturer's current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Camelot, Camelot -II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Slate, Grand Slate II and Woodland require minimum five (5) nails per shingle. ➢ Slateline requires minimum six (6) nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units .vertical in 12 units horizontal, special methods of fastening 'are required. Contact the shingle manufacturer for details: .6.4 Hip & Ridge Shingles: 6.4.1 Installation of Sea! -A -Ridge, Seal -A -Ridge Armorshield and Seal -A -Ridge IR asphalt shingles shall,comply with the manufacturer's current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel "Loctite PL S30 Roof & Flashing Sealant". �- a1-5' Saa%v�k I,: (M2 is ql 1, % IlArcte { 5 MM) {2Lm' FnduittMV4hdil6 Mall ctavo Ml Malj {9D5 anon} Exterior Research and Design, LLC. Evaluation Report 01S06.01.08-1113 Certificate of Authorization #9503 FL10124-RII Revision 13: 08/29/2013 Page 4 of S w i l�RINI t Y ( ER® 6.4.2 Installation of Timbertex Hip and Ridge asphalt shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails,' minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. VLSI t C'�-� rnrn) t' �allanla . P? rnm} S25m nduftdYtanaht iti t NWI t Hoer {� 9' (222 Mn t2 6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt •shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC - QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Certificate of/luthorization #9503 Evaluation Report 01506.01.08-1113 . FL10124-R11 Revision 13: 08/29/2013 Page 5 of 5 line- -ID15-7 459 SE Sandia Dr.,.Port St. Lucie Courtesy of Property Appraiser w