HomeMy WebLinkAboutSUBMITTED PAPERS[-DATE: _,) I k , -sl I SEES DUE: (
RECEIPT #:
I Permit #: (' -A )c-,4, —tJ
Planning & Development Services Department
Building & Code Division 8C
Virginia,1�
0
Ft. Pierce, FL 34982-5652 �t
Tel.772-462-1553 �
APPLICATION. FORSNSTRUCTIONS ROOF PERMIT cbun fy.
De SEE REVERSEME FOR
1. Location/Site Address: a%j2_
2. Parcel ID Number:
Office Use
Only
Section
Township
Ran a
Map Page
Zoning
Land Use
I '
3. Description of Project or Work Activity:
4. Total Roof Area (square feet):
6. Type of Roof:
] Fiberglass Shingle [ ] Coi
[ ] Tar & Gravel
] Ma_�___
[ ] Product Approval required for all types of Roofing Material (2 Sets)
] All Commercial Roofmg requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required
7. Owner Inform; tionW.� 8.
Name: i
Address:
City: �,4 &2 C A State'
•
Zip: Phone:
9. Value of Construction: $
Contractor Information
FL Reg/Cert #: I-r-r j,IU -7-7 9 ( o
County Cert #: .2
Business Name:; < �IPDA r . z r
Cell Phone:
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be
done in compIianceAith all applicable laws regulating construction and zoning.
r
P T QUALI TE RS NAME SIGNAT OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY OF -
ACKNOWLEDGED ACKNOWLEDGED BEFORE ME THIS DAY OF ��
20 L , BY Ns icy A.— .f_ Q)
C1J
WHO E ONALLY O ✓ TO ME OR HAS PRODUCED QS.IDENTIFICATION
�-ju�s � cum �► � _ } .p.G ..
-4ftNATU-Ry-01'FN-0TARL1V YPE O PRINT NAME O NOTARY �n
c
COMMISSION NUMBER '1 Cofl111NS W-4 961&
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT.,..,MAX
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
[era
Revised 4/26/2010
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY
FILE # 3924970 OR BOOK 3; PAGE 2797, Recorded 02/13/2014 at ,.0 PM
NOTICE OF COMMENCEMENT
Permit No. Tax Folio No.
State of Florida County of St. Lude
The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,
the following Information is provided In this Notice of Commencement.
..PC 3)
s-4j m,
Owner infopnation or Lessee Inferpution If the Lessee contracted for the Improvement:
Name / d.wf 1 + (-NAO I A c hA,.nl. . J4e
Address SW -3 I&M kin 124-Ach Fi �t/9
Interest in property:_,dK"
Name and address of fee simple titleholder (if different from Owner listed above):
Contractor's
Phone Number:
Surety (if applicable, a copy of the payment bond Is attached): Amount of bond: $
Name and address: Phone number.
Lender Name: Phone Number.
Lenders address:
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section
713,13(1) (a)7., Florida Statutes:
Name: Phone Number:
Address:
In addition to himself or herself, Owner designates of
Uenor's Notice as provided In Section 713.1 1) (b), Florida Statutes.
Phone number of person or entity designated by owner.
to receive a copy of the
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 year from the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SiTE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under pe Ity of perjury, I declare th ve read the foregoing notice of commencement and that the facts stated therein are true to the best of
m`y/kno�anbe�
T
(Signature of Owner or Lessee, nets r Lessee's Authorized Officer/Director/Partner/Manager
ai p v
(Sf tory'sTitle/Office)
The foregoing instrument was acknowledged before me this44day of.JrZb— , 20d
By of Person as T �l'� Q Y fore' rn far cAti �r �/�
Ty of �4f}i rustee Party on behalfof wh Instrument as executed
Aystftw
�� SW d Raldl ersonaliy known_ or produced Ident�cation�
(SW
S ure of otary Publk -State of Florida) # EE9516
(Print, Type, or Stamp Commissioned Name of Nota Pu b M2014 T e of Identification produced
STATE Of FLORIDA
ST. LUCIE COUNTY
THIS IS TO CERTIFYTHATTHIS IS A
TR 1E'""D CORRECT COPY V-T14E
Ohl GI W24 I
,
By
Qt
PAUL WELCH INC.
Fne C anical Electrical Civil Engineering
..1984 S. W. Biltmore St. Suite# 114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Fax (772) 785-9933
February 12, 2014
Re: Dougherty Roof
5503 Deleon Ave
Fort Pierce, FL 34951
SCOPE OF WORK-.
Remove existing roofing and install new 5-V Crimp Metal Roof (Sunlast Metals FL # 10490.6)
at above referenced residence address over new underlayment and existing plywood sheathing.
DESIGN CRITERIA:
FBC 2010
ASCE7-10
PROJECT DATA:
BUILDING HIEGHT = 8'-0"
A= 3.5'
MEAN ROOF HIEGHT = <15'
ROOF ANGLE = 3:12
SHAPE = PITCHED GABLE
ADJUSTMENT FACTOR =1.00
RVIPROTANCE FACTOR =1.00
WIND VELOCITY V ult =160 MPH
WIND VELOCITY V asd =124 MPH
EXPOSURE = B
ENCLOSURE CLASS = ENCLOSED BUILDING
INTERNAL PRESSURE COEFFICIENT = -0.18
APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (Dsf):
ZONE 1 (Field) = -25.3
ZONE 2 (Perimeter/ Ridge) = -42.7
ZONE 3 (Comers) = -62.8
5503 Deleon Ave Fort Pierce, FL 34951
1 of 3
ATTACHMENT REQUIREMENTS:
Metal roofing to be attached with Hex -Head wood screws with Weather Seal Washers (WSW)
#10 x 3/16" minimum penetration through deck spacing as follows:
ZONE 1 (Field): ROW SPACING =16" O.C., FASTENER SPACING =12" O.C.
ZONE 2 (Perimeter/ Ridge): ROW SPACING =16" O.C., FASTENER SPACING = 12" O.C.
ZONE 3 (Corners): ROW SPACING = 8" O.C., FASTENER SPACING =12" O.C.
Method # 1 ACCEPTABLE FOR ZONES # 1 & #2
Method #2 ACCEPTABLE FOR ZONES #3
Method #1 Design uplift Pressure: -50.5 psf
Method #2 Design uplift Pressure: - 106.75 psf
DECK INSTALLATION:
Re -nail all plywood sheathing (19/32" thick minimum) with 8D ring -shank nails at 4" O.C.
perimeter and 6" O.C. field for all zones.
All work to be in compliance with product approval (FL # 10490.6), manufacturer's
specifications, and the Florida Building Code 2010.
Submitted by:
PAUL LCH INC.
Paul elch, P.E.
Reg. No 29945
PW:pj
5503 Deleon Ave Fort Pierce, FL 34951 2 of 3
Ur
I
ROOF ZONE PLAN
A=3'
Q,Q,03 = ZONE DESIGNAHON (TYPICAL)
5503 Deleon Ave Fort Pierce, FL 34951
m
Paul Welch Inc.
Paul Welch P.E. Reg. No. 29945
February 12, 2014
3 of 3
Flonda Building Code Online
Page 1 of 3
fllolrlda 0.cpYeetf
BCIS Home i Log In User Registration I Flot Topics j Submit Surcharge Stats & Fact Publications 4 FBC Staff t BCIS Site Map Unks ; Search
Busines (,
Appraval
Professi nal*Product
USER: Public User
Regulation
Product Aohxoval Menu > Product or Acoliration
Search > Application List > Application Detail
FL #
FL10490-R3
Application Type
Revision
Code Version
2010
Application Status
Approved
Comments
Archived
Product Manufacturer Sunlast Metal
Address/Phone/Email 2120 SW Poma Drive
Palm City, FL 34990
(772)223-4055
flvalidation@yahoo.com
Authorized Signature James L. Buckner P.E.@CBUCK Engineering
jimmy@cbuckinc.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the James L. Buckner, P.E. @ C-Buck, Inc.
Evaluation Report
Florida License PE-31242
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2016
Validated By Steven M. Urich, PE
Z, Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
FL10490 R3 COI CertOflndeo.odf
Standard
Year
TAS 125
2003
UL 1897-98
2004
UL 580 with 1998 Revisions
2006
Florida Licensed Professional Engineer or Architect
FL10490 R3 Eouiv Test Standard Eouiv odf
Method 1 Option D
ht n://www.floridabuilding.org/i)r-/t r,,--wp dtl.aspx?param=wGEVXQwtDqudsDrIH6I48z... 2/12/2014
Florida Building Code Online
Page 2 of 3
Date Submitted
04/19/2012
Date Validated
04/21/2012
Date Pending FBC Approval
05/01/2012
Date Approved
06/11/2012
Summary of Products
FL #
IModel, Number or Name
Description
10490.1
1 - "PBR"
Roof Panel - 26 Gauge Steel, 36" Width, Attached to Plywood Deck
w/Optional Rigid Insulation
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10490 R3 II 1 PBR WoodDeck EVALREPORT.pdf
Approved for use outside HVHZ: Yes
Verified By: James L. Buckner, P.E P.E. #31242
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/-76.75
Evaluation Reports
Other: Refer to Evaluation Report for Limitations
FL10490 R3 AE 1 PBR WoodDeck EVALREPORT.pdf
and Conditions of Use. Refer to manufacturer's
Created by Independent Third Party: Yes
installation instructions as a supplemental guide
for attachment.
10490.2
2 - "1 in. Nailstrip"
Roof Panel - 24 Gauge Steel, 16" Width, Attached to Plywood Deck
w/Optional Rigid Insulation
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10490 R3 II 2 Nailstrip WoodDeck EVALREPORT.pdf
Verified By: James L. Buckner, RE P.E. *31242
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/-106.25
Evaluation Reports
Other: Refer to Evaluation Report for Limitations
FL10490 R3 AE 2 Nailstrip WoodDeck EVALREPORT.pdf
Created by Independent Third Party: Yes
and Conditions of Use. Refer to manufacturer's
installation instructions as a supplemental guide
for attachment.
10490.3
3 - "1-3/4 in.
Roof Panel - 24 Gauge Steel, 18" Width, Attached to Plywood Deck
SnapLock" (Steel)
w/Optional Rigid Insulation
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FLIG490 R3 II 3 1.75SnapLock WoodDeck EVALREPORT.pdf
Verified By: James L. Buckner, P.E P.E. #31242
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/-156.75
Evaluation Reports
Other: Refer to Evaluation Report for Limitations
FL10490 R3 AE 3 1.75SnaoLock WoodDeck EVALREPORT.Ddf
Created by Independent Third Party: Yes
and Conditions of Use. Refer to manufacturer's
installation Instructions as a supplemental guide
for attachment.
10490.4
4 - "1-3/4 in.
Roof Panel - 0.032 Aluminum, 14" Width, Attached to Plywood Deck
SnapLock" (Aluminum)
w/Optional Rigid Insulation
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10490 R3 II 4 1.75SnapLock Alum WoodDeck EVALREPORT.Ddf
Verified By: James L. Buckner, P.E P.E. #31242
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/-114.25
Evaluation Reports
Other: Refer to Evaluation Report for Limitations
FLID490 R3 AE 4 1.75SnapLock Alum WoodDeck EVALREPORT.Ddf
Created by Independent Third Party: Yes
and Conditions of Use. Refer to manufacturer's
installation instructions as a supplemental guide
for attachment.
10490.5
5 - "copper clad stainless"
Roof Panel - 0.016" Copper -Clad Stainless Steel, 16" Width, Attached
to Plywood Deck w/Optional Rigid Insulation
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10490 R3 II 5 CopoerCladStainiess WoodDeck EVALREPORT.Ddf
Verified By: James L. Buckner, P.E P.E. #31242
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/-76.75
Evaluation Reports
Other: Refer to Evaluation Report for Limitations
FL10490 R3 AE 5 CopperCladStainiess WoodDeck EVALREPORT.pdf
Created by Independent Third Party: Yes
and Conditions of Use. Refer to manufacturer's
installation instructions as a supplemental guide
ment.
10490.6 j 16 - "5-V Crimp"
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-106.75
Roof Panel - 26 Gauge Steel, 24" Width, Attached to Plywood Deck
w/Optional Rigid Insulation
Installation Instructions
FL10490 R3 II 6 5V WoodDeck EVALREPORT.Ddf
Verified By: James L. Buckner, RE P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
http://www.floridabuildina.org/Dr/ter atop dti.asiDx?t)aram=wGEVXQwtDqudsDrIH6I48z... 2/12/2014
Florida Building Code Online
Page 3 of 3
Other: Refer to Evaluation Report for Limitations FL10490 R3 AE 6 5V WoodDeck EVALREPORT.odf
and Conditions of Use. Refer to manufacturer's Created by Independent Third Party: Yes
installation instructions as a supplemental guide
for attachment.
10490.7 7 - "Solar V" Roof Panel - 26 Gauge Steel, 17-1/2" Width, Attached to Plywood
Deck
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10490 R3 II 7 SolarV WoodDeck EVALREPORT.odf
Approved for use outside HVHZ: Yes Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/-106.50 Evaluation Reports
Other: Refer to Evaluation Report for Limitations FL10490 R3 AE 7 SolarV WoodDeck EVALREPORT.odf
and Conditions of Use. Refer to manufacturer's Created by Independent Third Party: Yes
installation instructions as a supplemental guide
for attachment.
® Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :. Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do riot want your e-mail address released in response to a public -records request, do not send
eledronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under
Chapter 455, F.S., please dick here.
Product Approval Accepts:
M
Credit Carg
I SAFE
http://www.floridabuilding.orglpr/pr app_dtl.aspx?param--vGEVXQwtDqudsDrIH6I48z... 2/12/2014
Sp@Cldl w r=tr1. C=ftxCN E X21f 1636"11Q
Evaluation Report
"5V Crimp"
Metal Roof Assembly
Manufacturer:
Sunlast Metal, Inc.
2120 SW Poma Drive
Palm City, FL 34990
(772) 223-4055
for
Florida Product Approval
# FL 10490.6 R3
:.J
CBUCK, Inc. Certificate of Authorization #8064
Florida Building Code 2010
Per Rule 9N-3
Method: 1- D
Category: Roofing
Sub - Category: Metal Roofing
Product:
"5V Crimp" Roof Panel
Material:
Steel
Panel Thickness:
26 gauge
Panel Width:
24"
Support:
Wood Deck
Prepared by:
James L. Buckner, P.E., S.E.C.B.
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Project Manager: Diana Galloway
Report No. 12-139-5V-S6W-ER
Date: 4 / 16 / 12
Contents:
Evaluation Report Pages 1— 7
CBUCK, Inc.
1399 N. Killian Drive, Suite 4, West Palm Beach, Florida 33403
Phone: (561)491-9927 Fax: (561)491-9928 Website: www.cbuddnc.net
ej
r �
a/esL. Buckner, P.E., SECS
Florida f.E. # 11242
4-1-11Z-
FL #: FL 10490.6-113
Date: 4 / 6 / 12
CBUCKering Report No.: 12-139-5V-S6W-ER
Page 2 of 7
SP6211=14:5WU Struah em a 101, CBUCK, Inc. Certificate of Authorization #8064
Manufacturer:
Product Name:
Product Category:
Sunlast Metal, Inc.
"5V Crimp"
Roofing
Product Sub -Category Metal Roofing
Compliance Method: State Product Approval Rule 9N-3.005 (1) (d)
Product/System "5V Crimp"
Description: 26 gauge Steel roof panel mechanically attached to Plywood Deck with screws.
Product Assembly as Refer to Page 4 of this report for product assembly components/materials &
Evaluated: standards:
1. Roof Panel
2. Fasteners
3. Underlayment
Support: Type:
Wood Deck
(Design of support and its attachment to support framing is outside the scope of
this evaluation.)
Description:
• 15/32 (min.) or greater plywood,
• or Wood plank (min. specific gravity of 0.42)
Slope: Minimum slope shall be in accordance with manufacturer's recommendations, FBC
Section 1507.4.2 and applicable code sections.
Performance: Wind Uplift Resistance:
• Design Uplift Pressure: METHOD 1: - 50.5 PSF
(Refer to "Table A" attachment details herein) METHOD 2:-106.75 PSF
` I _
FL #: FL 10490.6-113
Date: 4 / 6 / 12
Report No.: 12-139-5V-S6W-ER
Page 3 of 7
spew-neaU St ictLwal ETigrievqing CBUCX Inc. Certificate of Authorization #8064
Performance Standards: The product described herein has demonstrated compliance with:
• UL580-06 — Test for Uplift Resistance of Roof Assemblies
• UL 1897-04 —Uplift testfor roof covering systems
• TAS 125-03 —Standard Requirements for Metal Roofing Systems
Standards Equivalency: The UL 580-94 & UL 1897-98 standard version used to test the evaluated product
assembly is equivalent with the prescribed standards in UL 580-06 & UL 1897-04
adopted by the Florida Building Code 2010.
Code Compliance: The product described herein has demonstrated compliance with Florida Building
Code 2010, Section 1504.3.2.
Evaluation Report This product evaluation is limited to compliance with the structural requirements
Scope: of the Florida Building Code, as related to the scope section to Florida Product
Approval Rule 9N-3.001.
Limitations and • Scope of "Limitations and Conditions of Use" for this evaluation:
Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance
with Rule 9N-3.005. Per Rule 9N-3.004, the Florida Building Commission is
the authority to approve products under "Optional Statewide Approval'.
• Option for application outside "Limitations and Conditions of Use"
Rule 9N-3.005(1)(e) allows engineering analysis for "project specific approval
by the local authorities having jurisdiction in accordance with the alternate
methods and materials authorized in the Code". Any modification of the
product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the
responsibility of others.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 9N-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 9N-3.0005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA
1824).
FL #: FL 10490.6-113
Date: 4 / 6 / 12
CBUCK E=Qineering Page Report No.: 4 12-139
7 SV S6W-ER
SPEilaffu St'fu=tL wed a lQI1"x2ennQ CBUCK, Inc. Certificate of Authorization #8064
Components/Materials
(by Manufacturer):
Roof Panel:
Material:
Thickness:
Panel Width:
Rib Height:
Yield Strength:
Corrosion Resistance:
Fastener:
Type:
Size :
Corrosion Resistance:
Standard:
"5V Crimp"
Steel
26 gauge (min.)
24" (max.) Coverage
1/2.,
40 ksi min.
In compliance with FBC Section 1507.4.3:
• ASTM A792 coated, or
• ASTM A653 G90 galvanized steel
Hex -Head Wood Screw with WSW
#10 x 1-1/2" "
Per FBC Section 1506.6 and 1507.4.4
Per ANSI/ASME B18.6.4
Underlayment:
Per roofing manufacturer's guidelines in compliance with FBC Section 1507.4.5
Insulation (Optional):
Type: Rigid Insulation Board
Thickness: 3" (max.)
Properties:
Density: 2.25 pcf (Ibs/ft3) min.
Or Compressive Strength: 20 psi min.
Insulation shall comply with FBC Section 1508. When insulation is incorporated,
fastener length shall conform to penetrate thru bottom of support a minimum of
3/16".
FL #: FL 10490.6-113
Date: 4 / 6 / 12
Report No.: 12-139-5V-56W-ER
Page 5 of 7
Ispecie f'y cs. i-ruchxdl eng ng CBUCK Inc. Certificate of Authorization #8064
Installation: Installation Method:
(Refer to drawings on Pages 6-7 of this report.)
■ Row spacing: Refer to Table "A"
(along the length of the panel)
■ Fastener spacing: Nominal pattern of 12" o.c.
(along the row, across the panel profile & at the top of corrugation peaks)
■ Rib Interlock: Lapped
■ Minimum fastener penetration thru bottom of support, 3/16".
■ For panel construction at the end of panels, refer to manufacturer's
instructions and any site specific design.
TABLE "A"
METHOD 1:
METHOD 2:
Design Pressure:
- 50.5 PSF
-106.75 PSF
Row Spacing:
16"
8"
Fastener Spacing:
12"
12"
Install the "5V Crimp" roof panel assembly in compliance with the installation
method listed in this report and applicable code sections of FBC 2010. The
installation method described herein is in accordance with the scope of this
evaluation report. Refer to manufacturer's installation instructions as a
supplemental guide for attachment.
Referenced Data: 1.
TAS 125-03 Uplift Test
Hurricane Test Laboratory, LLC (FBC Organization #TST ID: 1527)
Report #: 0412-1017-05, Report Date: 02/22/06
2.
Quality Assurance
By Keystone Certifications, Inc. (QUA ID: 1824)
Sunlast Metal & Solar, Inc. Licensee # 385
3.
Engineering Analysis
By CBUCK Engineering
4.
Equivalency of Test Standard Certification
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
5.
Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
FL #: FL 10490.6-R3
Date: 4 / 6 / 12
CBUCK Engineering Page Report No.: 162-139-5V-56W-ER
SpEaalafty cr. t-n-x--a' &rQr*a%=.arQ CBUCK, Inc. Certificate of Authorization #8064
Installation Method
Sunlast Metal, Inc.
"5V Crimp" (26 Gauge) Roof Panel Attached to Wood Deck
Profile Drawings
24" Maximum. Net Coverage
c
N
"5V Crimp" Panel
Typical Panel Profile View
Nominal 12" o.c. I Nominal 12" o.c.
Fastener Spacing
Across Panel Width
#10 Hex -Head Screw with WSW
Spaced 12" across the Panel
Assembly Profile View
Typical Fastening Pattern Across Row
• 1
FL #: FL 10490.6-R3
Date: 4/6/12
®BUCK L—Qia ri g Page Report 12-139
-1 7-SV-S6W-ER
�N
spCiia•U Stn-m=rL wcsi e to wq--inQ CBUCX Inc. Certificate of Authorization #8064
Installation Method
Sunlast Metal, Inc.
"5V Crimp" (24 Gauge) Roof Panel Attached to Wood Deck
Panel Fasteners -
#10 Hex Head
15W or greater Plywood, or Insulation x maximum
- Wood plank
Typical Assembly Isometric View
TABLE "A"
METHOD 1:
METHOD 2:
Design Pressure:
- 50.5 PSF
-106.75 PSF
Row Spacing:
16"
s"
Fastener Spacing:
12"
12"
Planning & Development services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-2165 or 772-462-2172
Fax: 772-462-6443
ROOF INSPECTION AFFIDAVIT
Re: Permit # III da ),
P I
AL ��� [01 , licensed as a( �ontraqte/Engineer/Architect
(Please print name & circle license type) *FS468pector
*General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection.
On or about % I did personally inspect the roof deck nailing
(Date)
work at: Jr�r� (��,1 &7�Y +O..-
(Job site address)
Based upon that examination I have determined the installation was done according to the Hurricane
Mitigation Retrofit Manual (Based on 553.844 F.S.)
sip
i ature and Seal
STATE OF FLORIDA
COUNTY OF cjh L—e—
License #
Swot to and subs d ed before me this t 3 day of �C `J 20A
by c C'yji,( . f Lo Who is pertly known to me or who has produced
as identification.
Notary Public, State of F d
Signature of Notary: 7114-
Commission Number: (Sea)
En 01/19/2011
:v;<-ampton
State of Florida
My Commission # EE 961
EVires d*'10, 2014