Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE: FEES DU... RECEIPT #: Permit #: 423, Planning & Development Services Department Building & Code Regulation Division 7�02300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel. 772-462-1553 S C%JVE APPLICATION FORROOF PERMITSEE REVERSE SIDE FOR SNSTRUCTIONS S t ! uc/ CG, , 1. Location/Site Address: d (ALL C DE LA G OS r7�s, 2. Parcel ID Number: 130/" /// - 000/- voo -S Office Use Only Section Township Range Map Page Zoning Land Use i Initials 3. Description of Project or Work Activity: gcoe) C S1 //IYGL.F 4CV r - _27L)Sr4te_ J6 G'A METAL da)rF 4. Total Roof Area (square feet): 90,1 5. Roof Pitch: c:,9 A / �12 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel [ ] Modified Bitumen V] Other /-/t A L [ x] Product Approval required for all types of Roofing Material (2 Sets) ] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product Approval attached Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information 8. Contractor Information Name: PA 7"T(/ SLJC E`F Address: 98 (ALCC- DCZ Z4GCS City: ql P/ Cie C E State: FL FL Reg/Cert #: (IOW County Cert #: 95P 9 Business Name: B/G t 4 KE 9cb4r_M1G _� eFPAIRZ Zip: 3`iSS J Phone: 97a -f 7- 0.3Cell Phone: e 63- (,3Y- )/2 y D G 9. Value of Construction: S 'y�% 50 — "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWIN ER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance xi r all applicable laws regulating construction and zoning. JO S6-o14 f/- BAXE2 04$2-. PRINT QUALIFIERS/OWNERS NAME SIGNATURIf OF QUALIFIER/ONVINEIZ STATE OF FLORIDA, COUNTY OF 5T. LUCW / ACKNOWLEDGED BEFORE ME THIS 7 DAY OF J/)/✓0A/1(,20_2(/� BY �osri� �- 1341�12�11e - WHO IS PERSONALLY KNOW7,,4�_TO ME OR HAS PRODUCED AS IDENTIFICATION IVIIn 9r0 VIKKI LYNN AARON SIGNATURrOk XOTARY TYPE OR PRINT NA2%IE OF NOTARY (seal) d f MY COMMISSION #FF007113 COMMISSIONNUMBER"�•','F'csti°PPt EXPIRES July 1, 2017 (w) 398-cm FlorldallotaryService.com NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF CONIMENCENIENT NIAY RESULT IN YOUR PAYING TWICE FOR INIPROVENIENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING -YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 Property Appraiser - St.Lucie County, FL http://www.paslc.org/paslc/prc.asp?prclid=130111100010005 r Wynne Building Corp Record: I of 5 Property Identification Site Address: 14 LA VILLA WAY B Secfrown/Range: 01 :34S :39E Map ID: 13/01 N Zoning: PUD PROPERTY RECORD CARD <<Prev Next» Spec.Assrmt Taxes Parcel ID: 1301-111-0001-000-5 Account#: 317 Use Type: PRKGIMOBILE City/Cnty: Saint Lucie County Exemptions Permits Horne Print r I Ownership and Mailing Legal Description Owner. Wynne Building Corp 134 39 E 1/2-LESS AS IN ORS 2639-2,263: 2652-2429: 2664-2695: Address: 12804 SW 122nd Ave 2678-378,381: 2688-516: 2701-276: 302 Miami FL 33186-6203 More... Sales Information Assessment 2013 Total Land and Building Date Price Code Deed Book/Page 2013 Final: 27730500 Land Value: 9330000 Acres: 314.94 1/1/1980 950000 00 CV 0324 / 2491 Assessed: 27730500 Building Value: 18400500 11/1/1978 390000 00 CV 0307 / 1544 Ag.Credit: 0 Finished Area: 20125 SgFt Exempt: Taxable: Taxes: 561606.39 BUILDING INFORMATION Exterior Features View: - RoofCover: - RoofStruct: - ExtType: MHPK - MH Parks YearBit: 1982 Frame: - Grade: C - C EfIYrBft: 1982 PrimeWall: - StoryHght: 0010 - 1 Story No.Units: 1244 SecWall: - Interior Features BedRooms: 1 Electric: - PrmintWall: - FullBath: 0 HeatType: - AvgHt/Fl: 1/2Bath: 0 HeatFuel: - Prm.Flors: - %AIC: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Use Type Type Measure Depth CNC2 - CONCRETE LOW Y 1 7200 AV AV 1982 1 2800-PRKG/MOBILE 176 -Site 1236 CNC2 - CONCRETE LOW Y 1 5952 AV AV 1982 FEW - CHAINLINK 10 Y 1 200 AV AV 1982 FEN4 - CHAINLINK4' Y 1 160 AV AV 1982 FEN6 - CHAINLINK 6' Y 1 665 AV AV 1982 ASP1 - ASP1 HIGH Y 1 199380 AV AV 1982 CSAV - COM POOL AVG Y 1 2720 AV AV 1982 PA01 - POOL DK-AVG Y 1 6304 AV AV 1982 CURB - CEMENT CURB Y 1 695 AV AV 1982 ASP1 - ASP1 HIGH Y 1 360000 AV AV 1982 1 of 2 1/19/2014 10:03 AM JOSEPH E. SMITH, IRK OF THE CIRCUIT COURT — SAI LUCIE COUNTY FILE # 3918490 C4:-OOK 3598 PAGE 987, Recorded 24/2014 at 03:36 1 Permit No. NOTICE OF COMMENCEMENT Tax Folio No. 1301-111-0001-000-5 State of Florida County of St. Lucie The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. Legal Description of Property: (and street address if available): 98 Calle del Lagos 1-34-39 General description of improvement: Re —roof Owner Information c r Lessee information if the Lessee contracted for the improvement: Name Patty Sweet Address _98 Calle del Lagos Fort Pierce, FL 34951 Interest in property:_ owner Name and address of Fee simple titleholder (if different from Owner listed above): Wynne Building Corp. 12804 SW 122nd Avenue Miami. FL 33186-6203 Contractor's Name: Big Lake Roofing & Repairs Contractor Address: 2699 NW 16th R1vd. Phone Number. 861-763-7663 Okeechobee, FL34972 Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ Name and address: not applicable Phone number: Lander Nams: not apnl t cahl a Phone Number: Lenders address: Parsons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by section 7313(1) (s)7., Florida statutes: Name: Address: Phone Number: In addition to himself or herself, Owner designates Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. -. .� (Signature of 0 ner or Lessee, or Owner's or Lessee's Authorized Officer/Director/Partner/Manager l, VIKKI LYNN AARON Patty Sweet, owner :f1 (Signatory's Title/Office) i MY COMMISSION MFPo071t3 'e;FM1d� EXPIRES July 1, 2017 The foregoing instrument was acknowledged before me this 17 thday of Jan 2014, ao ascots 1 FlorldeNotanrSarvleo.com By Patty Sweet as owner for Patty Sweet Na a ofl,erson Type of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed (Signature of N tary ublic - State of Florida) (Print, Type, or Stamp Commissioned Name of Notary Public) Vikki Lynn Aaron Personally known X or produced Identification` Type of Identification produced STATE OF FLOR DA ST. LUG CQNTY THIS I {C CERTIFY THATTHI IS TRUE A CORRE ` COON OF TI ORIGINA C R' Gu• �, U Dete• J c1.'2014 r . ti � II I _ 1 �1 it QQW;1D 'd Z,o J:4 09 .2`6 -r � 1 �11r. All 4 l + ` r ✓ _ � ! � _ {�� � = � —_ � �_ � =� � _ �_ _ — � � fit. a n. s ou" Wt • I • dip • _ • dop r 4b • • • • • • • • . nr N Florida Building Code Online FloNda Npafi ent Businesc(w) Professional Regulation :.� FI BCIS Home 1, Log In User Registration 1 Hot Topics ( Submit Surcharge j Stats & Facts I Publications ( FBC Staff ( BCIS Site Map ( Links I Search �.t . ,Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail "?r - FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) THESE PLANS AND ALL PROPOSED WORK FLRi ARE SUBJECT TO ANY CORRECTIONS 2010 Revvisionision REQUIRED BY FIELD INSPECTORS THAT Approved MAY BE NECESSARY IN ORDER TO Approved COMPLY WITH ALL APPLICABLE CODES. ICI Gulf Coast Supply & Manufacturing, LLC. 4020 S. W. 449th Street Horseshoe Beach, FL 32648 (352)498-7852 ray@gulfcoastsupply.com Ray Bowen ray@gulfcoastsupply.com U - L ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANC REVIEWED BY Roofing DATE 4 Metal Roofing PLANS A D PER IT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE Evaluation Report from a n a egistered Architect or a Licensed Florida Professional Engineer ® Evaluation Report - Hardcopy Received Terrence E. Wolfe CONO D FASTENERS ORATTACH PE-44923 ARC THE {RUPPO0I8II ITV OF THE Keystone Certifications, Inc. C�NI(V'IVJQR OF t�VY� 04/12/2014 I Locke Bowden [«`1 Validation Checklist - Hardcopy Received FL11651 R1 COI Letter of Certif.odf FL11651 R1 COI Letter of Name change.pdf Standard Year http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5... 1 /30/2014 Flgrida Building Code Online M FM 4471 1995 FM 4471 2010 TAS 100 1995 TAS 125 2003 UL1897 2004 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code 11"LE COPY Product Approval Method Method 1 Option D Date Submitted 02/15/2012 Date Validated 02/23/2012 Date Pending FBC Approval 02/29/2012 Date Approved 04/03/2012 Summary of Products Go to Page 0 0 Page 2/ 2 0 0 FL.# jModel, Number or Name Description 11651.21 26 Ga. Tuff Rib 26 Ga. Tuff Rib 36" Wide over 1 x 4 Wood Pulins over 1115/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 Rl II 26 Ga. Rib overlx4 purlins NONHVHZ details.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +N/A/-164.2PSF Created by Independent Third Party: Yes Other:-109.25 psf @ 24" o.c. fasterner spacing. - Evaluation Reports 164.25" psf @ 12" o.c. fastener spacing. Install per FL11651 R1 AE 26 Ga. Rib Panel over 1x4 NON HVHZ Roof 2010 format.pdf manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes 1165}i. 26iGa. TiuffRib 26 Ga. Tiuff Rib 36" W,ide over 15/32" Plywood -- Limits of t)se - Installation Instructions Approved for use in HVHZ: No FL11651 R1 II 26 oa. Rib over .5 plywood NONHVHZ details.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +N/A/-159.2PSF Created by Independent Third Party: Yes Other: -69.25 psf @ 24" o.c. fastener spacing.-159.25 Evaluation Reports psf @ 12" o.c. fastener spacing. Install per FL11651 R1 AE 26 Ga. Rib Panel over .5 Plywood NON HVHZ Roof 2010 format.pdf manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes 11651.23 1126 Ga. Tuff Rib 26 Ga. Tuff Rib Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R1 II 26 Aa Rib over .5 plvwood HVHZ Details.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +N/A/-159.2PSF Created by Independent Third Party: Yes 4 Other: -71.75 psf @ 24" o.c. fastener spacing.-159.25 Evaluation Reports psf @ 12" o.c. fastener spacing. Install per FL11651 R1 AE 26 Ga. Rib Panel over .5 Plvwood HVHZ Roof 2010 format.pdf manufacturers details. For use in HVHZ Zones. Created by Independent Third Party: Yes 11651.24 26 Ga. Tuff Rib 26 Ga. Tuff Rib Roof Panel over 1x4 Wood Purlins over http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frZeCSHgw99R5... 1 /30/2014 Florida Building Code Online II 1115/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R1 II 26 Ga. Tuff Rib over 1x4 and plywood details.pdf. Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +N/A/-164.2PSF Created by Independent Third Party: Yes Other:-106.75 psf @ 24" o.c. fastener spacing.-164.25 Evaluation Reports psf @ 12" D.C. fastener spacing. Install per FL11651 R1 AE 26 Ga. Rib Panel over 1x4 HVHZ Roof 2010 format.odf manufacturers details. For use in HVHZ Zones. Created by Independent Third Party: Yes 11651.25 29 Ga. Tuff Rib 29 Ga. Tuff Rib 36" Roof Panel Wide over 1 x 4 Wood �Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R1 II 29 GA. Rib over 1x4 purlins NonHVHZ Details.i3df Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +N/A/-123.5PSF Created by Independent Third Party: Yes Other: -76.75 psf @ 24" o.c. fastener spacing. -123.5 Evaluation Reports psf @ 24" D.C. fastener spacing. Install per FL11651 R1 AE 29 Ga. Rib Panel over 1x4 NON HVHZf 2010 .odf manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes 11651.26 29 Ga. Tuff Rib 29 Ga. Tuff Rib 36" Wide over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Installation Instructions FL11651 R1 II 29 Ga. Rib Panel over.5 Plywood NON HVHZ details.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Design Pressure: +N/A/-146.OPSF Created by Independent Third Party: Yes Other: -71.75 psf @ 24 D.C. fastener spacing. -146.0 Evaluation Reports psf @ 12" o.c. fastener spacing. Install per FL11651 R1 AE 29 Ga. Rib Panel over .5 Plywood NON HVHZ Roof 2010 .pdf manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes 11651.27 1129 Ga. Tuff Rib 29 Ga. Tuff Rib Roof Panel over 1x4 Wood Purlins Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R1 II 29 Ga. Tuff Rib over 1x4 over shingles Details.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 CDesign Pressure: +N/A/-101.OPSF Created by Independent Third Party: Yes Other: -101.0 psf @ 24" o.c. fastener spacing. Install Evaluation Reports per manufacturers details. Not for use in HVHZ Zones. FL11651 RI AE 29 Ga. Rib Panel over 1x4 NON HVHZ Roof. pdf Created by Independent Third Party: Yes 11651.28 1129 Ga. Tuff Rib 29 Ga. Tuff Rib Roof Panel over 7/16" OSB Decking Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R1 II 29 Ga. Tuff Rib over OSB details.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-116.OPSF Evaluation Reports Other: -22.66 psf @ 24" D.C. fastener spacing. -116.0 FL11651 R1 AE 29 Ga. Rib Panel over OSB NON HVHZ Roof 2010 format.odf psf @ 6" D.C. fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes Go to Page ? , .... Page 2 / 2 91 — ____7 099 Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f rrZeCSHgw99R5... 1 /3 0/2014 Florida Building Code Online record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: MR NN N M r+e . A'F`�E http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5... 1 /3 0/2014 FL# 11651.22 R1 Force Engineering & Testing Inc. 195301tamblewood Drive Humble,TX 77338 Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. 16 Ga. Tuff Rib Roof Panel over 15132" Plywood Florida Product Approval # 11651.22 111 Florida Building Code 2010 Per Rule 9N-3 Method: 1—D Category: Roofing Subcategory: Metal Roofing Compliance Method: 9N-3.005(1)(d) NON HVHZ Product Manufacturer: GULF COAST SUPPLY & MANUFACTURING, I.I.C. 4020 S.W. 449`h Street Horseshoe Beach, Florida 32648 Enaineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID:1920 Validator: Locke Bowden, P.E., FL #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1— 4 ,`�ti►Isllltrr��i *1101, CEMs<,p�i STATE ofIL : aC ,'�� �1�I Iti11►0�� February 22, 2012 FILE COPY Force Engineering &Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2010, Sections 1504.3.2. Product Description: Tuff Rib,'/" Rib Roof Panel, Min. 26 Ga. Steel, 36" Wide, through fastened roof panel over 15/32" Plywood decking. Non -Structural Application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2010 Section 1507.4.3. Paint finish optional Yield Strength: Min. 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2010, Section 1507.4.3. Panel Dimension(s): Thickness: 0.0185" min. Width: 36" Rib Height: %" major rib at 9" O.C. Panel Rollformer: MRS Metal Rollforming Systems Panel Fastener: Substrate Description: Design Uplift Pressures: FL# 11651.22 R1 #9-15 x 1-1/2" HWH Woodgrip with sealing washing or approved equal %" minimum penetration through plywood Corrosion Resistance: Per Florida Building Code 2010, Section 1506.6, 1507.4.4 Min. 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2010. Table "A" Maximum Total Uplift Design Pressure: f p 159.25 psf Fastener Pattern: 9" 6.5"-2.5"-6.5" Fastener Spacing: 1iP.c. / 12"O.C. *Design Pressure includes a Safety Factor = 2.0. C E N S F l A% .0 6 . �. .fit tJo.4i4� J(2 ✓ 'a • STATE OF ; OF-1 1) 10 1.911, NA February 22, 2012 Force Engineering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2010, Section 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2010, as relates to Rule 9N-3. Performance Standards: The product described herein has demonstrated compliance with: ■ UL 580-06 -Test for Uplift Resistance of Roof Assemblies ■ UL 1897-04 - Uplift Test for Roof Covering Systems Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No.117-0062T-07A, B, Dated 02/19/2007 2. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 9N-3.00S (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2010, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturer's recommended details. Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2010 Section 1507.4.5. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. FL# 11651.22 R1 % +,'111111rff1!!!I NBC E, Z. WD ii� C E k41 No. 47 -a • STATE OF :or Z. � ? mum February 22, 2012 rFor7ceEn7�g�ineefi�ngTesting Inc. 19530 Ramblewood Drive Hurnble,TX 77338 Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2010 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener FL# 11651.22 RI attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2010 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. CEHSFl�,�i No. h{R�? STATE OF ; a aim ��j s% ' ' ... • EN� i�I'F0 AL 1,1to 0 February 22, 2012 K# Asmussen Engineering LLC. Engineering & Environmental Services P.O. Box 1998, Okeechobee, FL. 34973-1998 Office: (863) 763-8546 Fax: (863) 467-8560 Memorandum Date: January 22, 2014 To: St. Lucie County Building Department Joe Cicio — Building Official 2300 Virginia Avenue Ft. Pierce, FL. 34982-5652 From: Loris C. Asmussen, P.E. Subject: Patty Sweet 98 Calle Del Lagos Fort Pierce, FL. 34951 W. ti I6a ii 1984 Twin Manor (24' x 37') Vehicle ID No. T23917518 A/B This memorandum is being provided to address re -roofing of an existing 1984 mobile home located at the address mentioned above (St. Lucie County). Proposed is Tuff Rib Roof Paneling (26GA metal — FL 11651.22R1) as a replacement to the originally manufactured roof, with Tamko Underlayments (FL 12328-R2). Attached are product approvals for this product and underlayment (including attachment methodology for the rib panels, as well as, underlayment). The roof product is manufactured by Gulf Coast Supply & Manufacturing, Inc. The product approval for the metal roof (#I 1651.22R1) is attached for your review and approval (Engineer Evaluator Terrence E. Wolfe, P.E. and Validated by Locke Bowden, P.E.). Based on my review of this proposed project, including product approvals and loads for which the above -referenced structure will be exposed to at this location in St. Lucie County (160 mph 3- second gust and exposure "C"), the project is found to be in substantial compliance with the 2010 Florida Building Code. Please contact my office at (863) 763-8546 with any additional comments or questions regarding this structure. Thanks for your attention to this matter. Sincerely, Loris C. Asmussen, P.E. Principle Enclosed Correspondence C: Sweet File 5J3Q/1 Rorida-Building .Code Online - - BCIS flame Log in user Registration Hot Topics Submit Surcharge Stats & Facts Publications Business,,, _ roval Professional iJti fi USER: Product bli PPer Product Approval hfenu -> Product or Application -Search > Application List Search Criteria F8C.Staff .BCIS Site. Map Links Search y. � ,., fr/ �•,, SjN 7 r Refine Search Code Version 2010 FL# 12328.10 Application Type ALL Product -Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Corrpriance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved For use outside HVHZ ALL Impact Resistant ALL -Design Pressure ALL Other ALL _Q w h 12=c Itc _ A. 1;­Fv,...,. FLr=t I TVpE Manufacturer I Validated fLV i Status FL12328-R2 Revision TAMKO Building Products, Inc. Robert J. M. Nieminen, PE I Approved History FL#:.FL12328.10 Model: No. 30 UL (203) 262-924S f ! Description: Asphalt saturated organic felt jl Category: Roofing Subcategory: Undedayments j !! FL12328-113 Editorial Change I TAMKO Building Products, Inc. Robert J. M. Nieminen, PE Pending FEC Approval FL#: FL12328.10 (203) 262-9245 j Model:.No. 30.UL Description: Asphalt saturated organic felt ,Category: Roofing _ Subcategory: Underlaynents f ;Approved by DBPR. Aoorovals by OBPR shall be revie d and —rirod K. me onr Contact Us :: 1940North Monme Street, Tallahassee FIL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Sopvripht 2007-2010 State of Florida :: Privacy Statement:: Accessibility Statement.::. Refund Statemen! Under Florida late, email addresses are public records. If you do not rant your e-mail address released In response to a publiL-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail_ If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455, F.S., please didc here . Product Approval Accepts: Acc a.1iAM E M sccuritv,Ti i,rn , www:floridabuilding.org/pr/pr app Istaspx 111 BUILDING PRODUCTS UNDERLAYMENT: An underlayment .consisting of asphalt saturated felt must be applied over the entire deck before the installation of TAMKO shingles. Apply the felt when the deck is dry. On roof decks 4 in. per foot and greater apply the felt parallel to the eaves lapping each course of the felt over the lower course at least 2 in. Where ends join, lap the felt 4 in. If left exposed, the underlayment felt may be adversely affected by moisture and weathering. Laying of the underlayment and the shingle application must be done together. CORPORATE HEADQUARTERS 220 W. FOURTH STREET P.O. BOX 1404 JOPLIN, MO 64802-1404 800-641-4691 tamko.com 1 ACCREDrTED ZONSTRUCTION TECWNOLOGIES U0, r L- efBORATQI IC TEST 4�E'E?ORT "-. Report for. Tamko Suilding:Products, Inc. 220 W. 4th Street Joplin, MO 64802 Attention: * Kern. Eden - Date: January 8, 2009 Product Name: No. 30 UL Manufacturer: Tamko Date Received: December 31, 2008 Source: Tamko PRI Report No.: TAP-219-02-01 Metro -Dade Notification No.: PR108124 Subject: The purpose -of this project was -to performance properties of Tamko Building products No. 3.0 UL (No. 30, Type 11) asphalt felt for compliance with Florida Building Code 2004 and 2007 (HVHZ) Testing Application Standard (TAS) 110 2000: TESTING REQUIREMENTS FOR PHYSICAL PROPERTIES OF ROOF MEMBRANES, INSULATION, COATINGS, AND OTHER ROOFING COMPONENTS, Section 2.2: Roofing Components within asphalt built-up and modified bitumen roof assemblies, and Florida Building Code 2004 and 2007; Sections -15072:3. 1607.3.3, 1507.5.3, and 1507.7.3: Underlayment using ASTU D 226-97a and ASTM D 226-06: Standard Specification forAsphalt Saturated Organic Felt Used in Roofing and Waterp oo-ling, Type II. Test Methods: The test methods. -used included - those found in - FBC TAS 110 2060: TESTING REQUIREMENTS -FOR PHYSICAL PROPERTIES OF ROOF MEMBRANES, INSULATION, COATINGS, AND OTHER ROOFING COMPONENTS and including: ASTM D 226: Standard Specification forA. sphalt-Saturated Organic Felt Used in Roofing and Waterproofing; ASTM D 146: Standard Test Methods for Sampling and Testing Bitumen -Saturated Felts -and Woven Fabrics for Roofing and Waterproofing; ASTM. D 727:. Test Method for Kerosine Number of Roofing and Flooring Feltby-the -Vacuum Method Sample . The sample received from Tamko Building Materials on December 31, 2008 was a full factory Description: - labeled'roll of felt. TAP 219-02-01 - PRI Accreditetions: IAS-ES TL-189• State of FlondaTST5878• Metro-Dade.Q6-1.116.02; CRRC Thetest results, opinions, or interpretations are based on the materialsupplied by the client. This report is for the exclusive use of stated client No reproduction or mile in any form can be made without the clients permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies, LLC. assumes no responsibility normakes a performance orwarranty statement for this material'or products and processes containing this material in connection with this report_ PRI ConsMaM M*Aab Technologies, LLa GM Badger (love Tampa. FL =18 Tel: 8*6214TU Fax 813b215840 a nw7 matetiaist�tln9�priu cmn 1M1IetS htlpJNrxs pdeml com Tamko Building Products Laboratory Test Report for No. 30 UL Saturated'Felt PR108124 Page 2 of 2 Results -of Testing:. Property .- 11 MethodResult Requirement 5. Materials and Manufacture D 226 Pass.: nrs4Physicial o o%paiitc)e�rdte�gf; i�equiirements 6.1 Table �::,=.:`:-::_�=_:_:=• .:.::-<:.�=--�'.::_ ... - MD 69 40 min - CMD 34 20 min Pliability @ 77°F D 146 Pass No cracking Loss on heating @ 221 OF, % 6A"t�bie 2- D 146 3.0 4 max Width of roll, in D 146 36.2 35 t 0.7% or as agreed' Area of roll, ft.Z D 146 217.5 216 or 432 min or as agreed' Moisture at point of manufacture, % D 146 3.2 4.1 max Net mass of saturated felt, Ib/100 f? D 146 26 26 min Mass of saturant, IbI100 if D 146 15.5 15 min Mass of desaturated felt, Ib/100 ft2 D 146 10.2 10 min Ash, % D 146 3.8 10.0 max Saturation, % D 146 152 150 min 6.2 Unroll @ 50 and 140'F D 226 Pass No -cracking. or sticking 6.3 Perforated felt D 226 NA Uniformly spaced perforations 7 Workmanship, Finish, D 226 PASS Thoroughly, uniformly saturated, no Appearance surfacing, free of visible defects Ivoie l . yr as agreea upon oy purcnaser and seller. Statement of Compliance: This product complies vAth all of the requirements of Florida Building Code 2004 and 2007 (HVHZ) Testing Application Standard (TAS) 110 2000: TESTING REQUIREMENTS FOR PHYSICAL PROPERTIES OF ROOF MEMBRANES, INSULATION, COATINGS, AND OTHER ROOFING COMPONENTS, Section 2.2: Roofing Components -within asphalt built-up and modified bitume roof.assemblies.-and.Florida.Building Code 2004 and 2007; Sections 1507.2.3,1507-3.3,1507-5.3, and 1507 7.3: Underlayment using ASTM D 226-97a: Standard Specification forAsphalt-Saturated Organic Felt Used in Roofing and Waterproofing, Type II. The product also complies with all of the requirements'of ASTM D 226-06: Standard Specification for Asphalt - Saturated Organic Felt Used in Roofing and Waterproofing, Type 11. Limitations: None. Signed: - Donald C. Portfolio President Signed: Duc T. Ng Florida Registered Pro Tonal Engineer P. E. Number. 65034 Date: //9Date: TAP-219-02-01 PRI Accreditations: IAS-ESTL-189• State of Florida TST587.8• Metro -Dade 06-1116.02• CRRC The test results, opinions. or interpretations are based an the material supplied by the client. This report is forthe exclusive use of stated client. No reproduction orfacsimile in any form can be made without the clients permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction.Materials Technologies, I.L.C. assumes no responsiblitynormakes a performance or warranty statement for this material or products and processes containing this material in connection with this report PRI ConsiWon MaMlais 7echnWogles, LLC. 6908 Badger Drive Tampa, FL 33610 Tel: 813-621-FM Fax 813421.58d0 e•m20 M terraistes0ng A( pricmtmm WebSlte: h8pJAvww.pri a= TAK0@ N0s30 UL PRODUCT DATA _Asphalt saturated Organic Felt � Manufactured in Joplin, MO, Frederick, MD, and Green Cove Springs, FL TAMKOO NO.30 UL SATURATED FELT features a tough TAMKO organic felt that is saturated with asphalt. Accepted for use as an underlayment felt to be applied over the roof deck prior to the installation of TAMKO f asphalt shingles.F11 N.!F fxz�2i [�il n-. U.L. Built -Up Type 30 Label ASTM D 226, Type II Roll Dimensions 72' X 36" Coverage per roll 2 Squares Laying Lines 2", 4", 17" 'All values stated as nominal THIS PRODUCT IS SOLD "AS IS" WITHOUT WARRANTIES, EXPRESSED OR .IMPLIED, INCLUDING THE .IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Visit our Web Site at tamko.com CAUTION: Ttds prod. d ups wood dust Vlbod dust has been classtied as a `bloom" human cuc hogar by the Intarational Agency for Rsseardr on Canoe QAW and the National Todcotogy Rogram. Tim pmduct also oantays ox tod mphalt Oczlpaborat expo to owd¢ed asphall and As anissamdua"vrgroofrighavebe3cdassfied bytARCasa'probadehuman cvraagac".OncWdasphzftalso oorrtaisPott cydchornat cHydrocar6ons same of0ilcrhavebeen classified byIA.RCasknavnorprobablehrn ncmanogens.Ttephyscalnahaeofttspudurctmayttdpriotanyutto.Boor damalhaz2rdduring app5oationadlarramoval.Hoxsv�phyacdfarssrrhassawsg.grndngordffMdunfngdernoitian+orkandheat gorbuartirg maycxzaasetheinharatlat ordemal expm irehazard offt produaTakep acartio s to p evettbreattM and crrrtdct vAtr slit_ ' AmayaaDDl", Central District 220 West4th St. Joplin, MO 64801 800-641-4691 Northeast District 4500 Tamko Dr. Frederick, MD 21701 800-368-2055 BUILDING PRODUCTS Southeast District 2300 35th St. Tuscaloosa, AL 35401 800-228-2656 Southwest District 7910 S. Central Exp. _Dallas, TX .752-16 .800-443-1834 TAMKO Logo, Roofer Logo and TAMKO' Western District 5300 East 43rd Ave. Denver, CO 80216 800-530-8868 are registered trademarks of TAMK01 Building Products, Inc. Information included in this product data sheet %vas current at time of printing. To obtain a copy of the most current version of this product data sheet, visit us online at tamko.com or call us at 800-641-4691. Rev. 0512012