HomeMy WebLinkAboutSUBMITTED PAPERSDATE:
FEES
RECEIPT #:
Permit #:
a
Planning & Development Services Department
Building & Code Regulation Division
2300 Virginia Avenue
Ft. Pierce, FL 34982-5652
Tel. 772-462-1553
APPLICATION FOR ROOF PERMIT
SEE REVERSE SIDE FOR INSTRUCTIONS
C1.
. ' V/
Cc
J�
1. Location/Site Address: 33 A Z t) L
2. Parcel ID Number: l3 o / - l / l - o 0 0 / - 00 0 -S
Office Use
Section
Township
Range
Map Page
Zoning
Land Use
I Ini ' is
`
Only
I,
3. Description of Projector Work Activity: fiEMovC sW ING LE ecz)F - INSTAL, 26 C4. MEr,4L /2c)OF-
4. Total Roof Area (square feet): %l 50 () S.f. 5. Roof Pitch: ;�31g
6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle
[ ] Tar & Gravel [ ] Modified Bitumen [X] Other 14ETA L
[x] Product Approval required for all types of Roofing Material (2 Sets)
] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: AAVL nl_ SA a L ES
Address: 33 ,A Z U L
City: FT Plenec State: rl-
Zip: ,M.5 / Phone: 77,7-2zlZ-6067o2
9. Value of Construction: $ 6,,Z Cm
FL Reg/Cert#: 0006-1G 93 9
County Cert #: �59a !2
Business Name: B/6'�F�,q�IZ�
Cell Phone: R63 -( 3c/- J/Z 4/
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTORIOWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be
done in compliance with all applicable laws regulating construction and zoning.
JOSS-aN /. 13EIXEe -Je -
PRINT QUALIFIERS/OWNERS; NAME SIGNATURE OF QUALI ER/OWNER
STATE OF FLORIDA, COUNTY OF ST
ACKNOWLEDGED BEFORE ALE THIS /% DAY OF ti QNU � 20 , BY JoS EPH
WHIO IS RSONALLY KNOWN TO ALE OR HAS PRODUCED AS IDENTIFICATION
VjT-k/� 4g rnVYKKI LYNN AARON
SIGNA : O OTARY TYPE OR NAME OF NOTARY s z°AA'
`�'
'• MY COMMISSION #FF007113
CODINIISSION NUMBER EFO07 �3 :} EXPIRES July 1, 2017
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMEENCEMENT MAY i m
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26/2010
JOSEPH E. SMITH, 'RK OF THE CIRCUIT COURT - SAI
FILE ## 3918492 O,__ OOK 3598 PAGE 989, Recorded
LUCIE COUNTY
24/2014 at 03:37 1
i
Permit No.
State of Florida County of St. Lucie
NOTICE OF COMMENCEMENT
Tax Folio No. 1301-111-0001-000-5
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,
the following information is provided in this Notice of Commencement.
Legal Description of Property: (and street address if available): 33 Azul
General description of Improvement: Re —roof
Owner Information or Lessee information if the Lessee contracted for the Improvement:
Name Paul N. Sayles
Address 33 Azul Fort _Pierce. FL 34951
Interest in property: owner
Name and address of fee simple titleholder (if different from Owner listed above):
Winne Building Corp. 12804 SW 122nd Avenue Miami, FL 33186-6203
Contractor's Name: Big Lake Roofing & Repairs
Contractor Address: 2699 NW 16th Blvd. Phone Number:863-763-7663
—OFeec o ee, L34
Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ _
Nameandaddress: not applicable Phone number:
Lander Name:_ not applicable Phone Number:
Lender's address:
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section
713.13(1) (a)7., Florida Stetutesi
Name: Phone Number:
Address;
In addition to himself or herself, Owner designates of
Lienoes Notice as provided in Section 713.1311) (b), Florida Statutes.
Phone number of person or entity designated by owner:
to receive a copy of the
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 year from the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of r1ury, declare that read the foregoing notice of commencement and that the facts stated therein are true to the best of
my knowledge d bell
(Signat a of Owner or Lessee, gr Ow r•s or Lessee's Authorized Officer/Director/Partner/Manager A 0.4!� VIKKI LYNN AARON
f
Paul N. Sayles. owner MY COMMISSION NFF007113
(Signatory's Title/office) do EXPIRES July 1, 2017
at1 7Ga-0113 PaddeNalary3orvlce.com
The foregoing instrument was acknowledged before me this 17 thday of Jan , ZD 14
By Paul N. Sayles as owner for Paul N. Sayles
Na of Person Type of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed
(Signature of N to ublic - State of Florida)
(Print, Type, or Stamp Commissioned Name of Notary Public)
Vikki Lynn Aaron
Personally known X or produced Identification_
Type of Identification produced
STATE OF FLORIDA
ST.�.UCJE000NTY
T IS'IS TO CERTI
TRU �7 ND CORK
ORId1N` AL .� ;r
Deputy Clerk
Date' JAN,
�a..Z014
IS
Property Appraiser - St.Lucie County, FL
http://WWW.Daslc.org/paslc/Prc.asp?prclid=130111100010005
Wynne Building Corp
Record:1 of 5
Property Identification
Site Address:
14 LA VILLA WAY B
Sec/Town/Range:
01 :34S :39E
Map ID:
13/01 N
Zoning:
PUD
PROPERTY RECORD CARD
«Prev Next» Spec.Assrmt Taxes
Parcel ID: 1301-111-0001-000-5
Account #: 317
Use Type: PRKG/MOBILE
City/Cnty: Saint Lucie County
Exemptions Permits Home Print
fF t1CIE00 i
Ownership and Mailing Legal Description
Owner: Wynne Building Corp 134 39 E 1/2-LESS AS IN ORS 2639-2,263: 2652-2429: 2664-2695:
Address: 12804 SW 122nd Ave 2678-378,381: 2688-516: 2701-276: 302
Miami FL 33186-6203 More...
Sales Information
Assessment 2013
Total Land and Building
Date Price Code
Deed Book/Page 2013 Final:
27730500
Land Value: 9330000 Acres: 314.94
1/1/1980 950000 00
CV 0324 / 2491 Assessed:
27730500
Building Value: 18400500
11/1/1978 390000 00
CV 0307 / 1544 Ag.Credit:
0
Finished Area: 20125 SgFt
Exempt:
Taxable:
Taxes:
561606.39
BUILDING INFORMATION
Exterior Features
View:
-
RoofCover:
-
RoofStruct: -
ExtType:
MHPK
- MH Parks YearBlt:
1982
Frame: -
Grade:
C - C
EffYrBR:
1982
PrimeWall: -
StoryHght:
0010 -1
Story
No.Units:
1244
SecWall: -
Interior Features
BedRooms:
1
Electric:
-
PrmintWall:
FullBath:
0
HeatType:
-
AvgHt/FI:
1/213ath:
0
HeatFuel:
-
Prm.Flors: -
%A/C:
0
%Heated:
0
%Sprinkled: 0
Special Features and Yard
Items
Land Information
Type
Y/S Qty.
Units Qual. Cond.
YrBlt.
No. Use Type
Type Measure Depth
CNC2 - CONCRETE LOW
Y 1
7200 AV
AV
1982
1 2800-PRKG/MOBILE 176 -Site 1236
CNC2 - CONCRETE LOW
Y 1
5952 AV
AV
1982
FEW - CHAINLINK 10
Y 1
200 AV
AV
1982
FEN4 - CHAINLINK 4'
Y 1
160 AV
AV
1982
FEN6 - CHAINLINK V
Y 1
665 AV
AV
1982
ASP1 - ASP1 HIGH
Y 1
199380 AV
AV
1982
CSAV - COM POOL AVG
Y 1
2720 AV
AV
1982
PA01 - POOL DK-AVG
Y 1
6304 AV
AV
1982
CURB - CEMENT CURB
Y 1
695 AV
AV
1982
ASP1 - ASP1 HIGH
Y 1
360000 AV
AV
1982
1 of 2
1/19/2014 10:03 AM
Florida Building Code Online
0
x . -
�� •
Floilda Pepaamentd BCIS Home Log In i User Registration ( Hot Topics ( Submit Surcharge i Stats & Facts Publications FBC Staff BCIS Site Map Links Search
Busines
�f��eSS0 ;Product Approval
I USER: Public User
Regulation
�imr�lrfer!�rtnim� Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL11651-R1 THESE PLATS AND ALL PROPOSED WORK
MIN Application Type Revision ARE SUBJECT TO ANY CORRECTIONS
Code Version 2010 REQUIRED By FIELD INSPECTORS THAT
Application Status Approved MAYBE NECESSARY IN ORDER TO
Comments COMPLY WITH ALL APPLIOASLE CODES.
Archived El
Product Manufacturer Gulf Coast Supply & Manufacturing, LLC.
Address/Phone/Email 4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352)498-7852
ray@gulfcoastsupply.com
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Ray Bowen
ray@gulfcoastsupply.com
e V
LDATE.
LUCIE COUNTY
LDING DIVISION
REVIEWED
R COMPLIA
Y
Roofing NS A PER IT
E KEPT ON JOB OR
Metal Roofing CTION WILL BE MADE
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Terrence E. Wolfe CONCEALED FASTENERS ORATTACHAI'S
ARE THE RESPONSIBILITY OF THE
Keystone Certifications, Inc. 23 CONTRACTOR OF RECORD
Keysto
04/12/2014
Locke Bowden
L Validation Checklist - Hardcopy Received
FL11651 R1 COI Letter of Certif.pdf.
FL11651 R1 COI Letter of Name chanoe.pdf
Standard
Year
http://www.floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeCSHgw99R5... 1/30/2014
Florida Building Code Online
El
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FM 4471
1995
FM 4471
2010
TAS 100
1995
TAS 125
2003
UL1897
2004
UL 580
2006
vFILIPM, COP
L��
Method 1 Option D
02/15/20,12
02/23/2012
02/29/2012
04/03/2012
Summary of Products
Go to Page i0 Page2/20 0
FL #
jModel, Number or Name
Description
11651.21
26 Ga. Tuff Rib
26 Ga. Tuff Rib 36" Wide over 1 x 4 Wood Pulins over
15/32" Plywood .
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R1 II 26 Ga. Rib overix4 Durlins NONHVHZ
details.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-164.2PSF
Created by Independent Third Party: Yes
Other:-109.25 psf @ 24" o.c. fasterner spacing. -
Evaluation Reports
164.25" psf @ 12" o.c. fastener spacing. Install per
FL11651 R1 AE 26 Ga. Rib Panel over 1x4 NON HVHZ
Roof 2010 format.Ddf
manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
1165ti1.22 26 Ga. Tuff Rib
26 Ga. Tuff Rib 36" Wide over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R1 II 26 ga. Rib over .5 Dlywood NONHVHZ
details.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-159.2PSF
Created by Independent Third Party: Yes
Other: -69.25 psf @ 24" o.c. fastener spacing.-159.25
Evaluation Reports
psf @ 12" o.c. fastener spacing. Install per
FL11651 R1 AE 26 Ga. Rib Panel over .5 Plywood NON
HVHZ Roof 2010 format.Ddf
manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.23 1126 Ga. Tuff Rib IF26
Ga. Tuff Rib Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R1 II 26 ga Rib over .5 plywood HVHZ
Details.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-159.2PSF
Created by Independent Third Party: Yes
Other: -71.75 psf @ 24" o.c. fastener spacing.-159.25
Evaluation Reports
psf @ 12" o.c. fastener spacing. Install per
FL11651 R1 AE 26 Ga. Rib Panel over .5 Plywood
HVHZ Roof 2010 format.Ddf
manufacturers details. For use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.24
26 Ga. Tuff Rib
26 Ga. Tuff Rib Roof Panel over 1x4 Wood Purlins over
http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5... 1 /30/2014
Florida Building Code Online 4
n
II 1115/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R1 II 26 Ga. Tuff Rib over 1x4 and plywood
details.Pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-164.2PSF
Created by Independent Third Party: Yes
Other:-106.75 psf @ 24" o.c. fastener spacing.-164.25
Evaluation Reports
psf @ 12" D.C. fastener spacing. Install per
FL11651 Rl AE 26 Ga. Rib Panel over 1x4 HVHZ Roof
2010 format.Pdf
manufacturers details. For use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.25
29 Ga. Tuff Rib
29 Ga. Tuff Rib 36" Roof Panel Wide over 1 x 4 Wood
Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R1 II 29 GA. Rib over 1x4 Purlins NonHVHZ
Details.Pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-123.5PSF
Created by Independent Third Party: Yes
Other: -76.75 psf @ 24" D.C. fastener spacing. -123.5
Evaluation Reports
psf @ 24" o.c. fastener spacing. Install per
FL11651 R1 AE 29 Ga. Rib Panel over 1x4 NON HVHZf
2010 .Pdf
i manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.26 1129 Ga. Tuff Rib
29 Ga. Tuff Rib 36" Wide over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 Rl II 29 Ga. Rib Panel over.5 Plywood NON
HVHZ details.Pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-146.OPSF
Created by Independent Third Party: Yes
i Other: -71.75 psf @ 24 o.c. fastener spacing. -146.0
Evaluation Reports
psf @ 12" o.c. fastener spacing. Install per
FL11651 RI AE 29 Ga. Rib Panel over .5 Plywood NON
HVHZ Roof 2010 .Pdf
manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.27 1129 Ga. Tuff Rib Jr29
Ga. Tuff Rib Roof Panel over 1x4 Wood Purlins
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R1 II 29 Ga. Tuff Rib over 1x4 over shingles
Details.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-101.OPSF
Created by Independent Third Party: Yes
Other: -101.0 psf @ 24" o.c. fastener spacing. Install
Evaluation Reports
per manufacturers details. Not for use in HVHZ Zones.
FL11651 R1 AE 29 Ga. Rib Panel over 1x4 NON HVHZ
Roof. Ddf
Created by Independent Third Party: Yes
11651.28 29 Ga. Tuff Rib IF29
Ga. Tuff Rib Roof Panel over 7/16" OSB Decking
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R1 II 29 Ga. Tuff Rib over OSB details.Ddf
Verified By: Terrence E. Wolfe, P.E. 44923
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-116.OPSF
Evaluation Reports
Other: -22,66 psf @ 24" o.c, fastener spacing. -116.0
FL11651 RI AE 29 Ga. Rib Panel over OSB NON HVHZ
Roof 2010 format.Pdf
psf @ 6" o.c. fastener spacing. Install per manufacturers
details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
Go to Page 0(d Page 2/ 2 0 0
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not
send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.
*Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frZeCSHgw99R5... 1 /30/2014
i � ^
rt:
rForcegineering & Vesting Inc.
19530 Ramblcwood Dnvc
Humble,TX 77338
Product Evaluation Report
GULF COAST SUPPLY & MANUFACTURING, LLC
26 Go. Tuff Rib Roof Panel over 15/.32" Plywood
Florida Product Approval # 11651.22 R1
Florida Building Code 2010
Per Rule 9N-3
Method: 1—D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 9N-3.005(1)(d)
NON HVHZ
Product Manufacturer:
GULF COAST SUPPLY & MANUFACTURING, I.I.C.
4020 S.W. 4Wh Street
Horseshoe Beach, Florida 32648
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID:1920
Validator•
Locke Bowden, P.E., FL #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1— 4
♦,�♦ � � C E� F, iy ��i�
O
w • �
a • STATE OF : ec
mum N AL
FL# 11651.22 R1
February 22, 2012
k
'
d
Force Engineering & Testing Inc.
19530 Rambletvood Drive
Htimble,TX 77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2010, Sections 1504.3.2.
Product Description: Tuff Rib, YV Rib Roof Panel, Min. 26 Ga. Steel, 36" Wide, through fastened roof
panel over 15/32" Plywood decking. Non -Structural Application.
Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2010 Section 1507.4.3. Paint finish optional
Yield Strength: Min. 80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2010, Section 1507.4.3.
Panel Dimension(s): Thickness: 0.0185" min.
Width: 36"
Rib Height: %" major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener:
Substrate Description:
Design Uplift Pressures:
FL# 11651.22 R1
#9-15 x 1-1/2" HWH Woodgrip with sealing washing or approved equal
%" minimum penetration through plywood
Corrosion Resistance: Per Florida Building Code 2010, Section 1506.6, 1507.4.4
Min. 15/32" thick, APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside'the scope of this
evaluation. Must be designed in accordance w/ Florida Building Code 2010.
T KA«
Maximum Total Uplift Design Pressure:
6 . 5 p
? 159.25 psf
Fastener Pattern:
. �,
6.5"-2.5"-6.5"-2.5"-
'
6.5"-2.5"-6.5"
Fastener Spacing:
�" CS..
12" O.C.
"Design Pressure includes a Safety Factor = 2.0.
�,��t</Illfffll��I
O
C t4 S �.t► �i
a • STATE OF : ar
.0,0 FL O RI ID
sso.arr�e.
a�AsnAa i�r, IJ'1111161100
�,,�
February 22, 2012
I
a
Force Engineering & Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2010, Section 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2010, as relates to Rule 9N-3.
Performance Standards: The product described herein has demonstrated compliance with:
® UL 580-06 - Test for Uplift Resistance of Roof Assemblies
■ UL 1897-04 - Uplift Test for Roof Covering Systems
Reference Data: 1. UL 580-94 / 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 117-0062T-07A, B, Dated 02/19/2007
2. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc.
(FBC Organization # ANE ID: 1920)
Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 9N-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2010, including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per manufacturer's recommended details.
Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2010 Section
1507.4.5.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
,��� dt•C E,
O
C 2 N S;
No. 444�
��•� STATE OF : a:
0 ID
auis1 ' • .... `
fill
FL# 11651.22 R1
February 22, 2012
ILCOpy
.'E
Force Engineering &'Testing Inc.
D'
19530YtItm CWood W.—
Humble,TX 77338
Design Procedure: Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2010 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2010
Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
FU 11651.22 RI
►►►�tits��i�rr�ri
D
No. 4:9
Jai
•a' STATE OF ; a
OWM
February 22, 2012
J ,
I
Asmussen Engineering
Engineering & Environmental Services
P.O. Box 1998, Okeechobee, FL. 34973-1998 Office: (863) 763-8546 Fax: (863) 467-8560
Memorandum
Date: January 22, 2014
To: St. Lucie County Building Department
Joe Cicio — Building Official
2300 Virginia Avenue
Ft. Pierce, FL. 34982-5652
From: Loris C. Asmussen, P.E.
Subject: Paul N. Sayles
33 Azul
Fort Pierce, FL. 34951
1984 Twin Manor (24' x 60') Vehicle ID No. T26316278 A/B
This memorandum is being provided to address re -roofing of an existing 1984 mobile home located
at the address mentioned above (St. Lucie County). Proposed is Tuff Rib Roof Paneling (26GA
metal — FL 11651.22R1) as a replacement to the originally manufactured roof, with Tamko
Underlayments (FL 12328-R2). Attached are product approvals for this product and underlayment
(including attachment methodology for the rib panels, as well as, underlayment). The roof product
is manufactured by Gulf Coast Supply & Manufacturing, Inc. The product approval for the metal
roof (#I 1651.22R1) is attached for your review and approval (Engineer Evaluator Terrence E.
Wolfe, P.E. and Validated by Locke Bowden, P.E.).
Based on my review of this proposed project, including product approvals and loads for which the
above -referenced structure will be exposed to at this location in St. Lucie County (160 mph 3-
second gust and exposure. "C"), the project is found to be in substantial compliance with the 2010
Florida Building Code.
Please contact my office at (863) 763-8546 with any additional comments or questions regarding
this structure. Thanks for your attention to this matter.
Sincerely,
Loris C. Asmussen, P.E.
Principle
Enclosed Correspondence
C: Sayles File
k
5130113 _ Florida_Building-Code.Online
5CIS Mome Log In User Registration Hot Topics Submit Surcharge Stall&Fads Publications
Business" �� _
ProfeSSional ?4 USER: Pubs Approval
r.
Pmduct Aooraval Menu > Product or Aooliratian Search > Application List
Search Criteria
FBGStaff 8CI5 Site Map
-Links JSearch
y ^
L q-- � r
Refine Sea c
Code Version
2010
FL#
12328.10
Application Type
ALL
Product Manufacturer
ALL
Category
ALL
Subcategory
ALL
Application Status
ALL
Compliance Method
ALL
Quality Assurance Entity
ALL
Quality Assurance Entity Contract Expired
ALL
Product Model, Number or Narne
ALL
Product Description
ALL
Approved for use in HVHZ
ALL
Approved for use outside HVHZ
ALL
Impact -Resistant
ALL
Design Pressure
ALL
Other
ALL
Search Results - Applications
lF�
TtfDe
Manufacturer
Validated By
I Status
I FL12328-R2
Revision
TAMKO Building Products, Inc.
Robert J. M. Nieminen, PE .r
Appmv_ed
History
FL#: FL12328.10
(203) 262-9245
Model: No. 30 UL
Description: Asphalt saturated organic felt
i
I
Category: Roofing
I
jSubcategory:
Underlayments
FL12328-R3
Editorial Change
TAMKO Building Products, Inc.
FL#: FL1232810
Robert J. M. Nierrinen, PE
`' Pending FBC Approval
li-M
!(203)
odel: No. 30 UL!
I
- 262-9245
Description: Asphalt saturated organic felt
I'
Category: Roofing
k
Subcategory: Underlayments
pprova s r ond„ tic &—cncu dnu rduneu uy the rut. ana/or one Commission if necessary.
'Contact Us :: 1940 North Monroe Street Tallahassee FL 32399 Phone: 850-487-1824
The State of flodda.is, an.AA/E3.O.employer-COpyrtaht 2007-2g18 State of,Florida.::-Privacy Statement :: Amessib0ity Statement.: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to
Section 4S5.275(1), Florida Statutes, effective October 1, 2012. licensees licensed under Chapter455, F.S. must provide the Department Wth an email address if
they have one. The emails provided may be used for official communication tdth the licensee. However email addresses are public record. if you do not wish to
supply a personal address, please provide the Department with an email address Yhich can be made available to the public To determine if you are a licensee
under Chapter455, F.S., please dick here .
Product Approval Accepts:
a PPE M
wvm.floridabLdIcUrig.org/pripr_appjstaspx 111
1TAMK01
99116IDING PRODUCTS
UN®ERLAYMENT: An underlayment consisting of asphalt saturated felt must be
applied over the entire deck before the installation of TAMKO shingles. Apply the felt
when the deck is dry. On roof decks 4 in. per foot and greater apply the felt parallel to the
eaves lapping each course of the felt over the lower course at least 2 in. Where ends join,
lap the felt 4 in. If left exposed, the underlayment felt may be adversely affected by
moisture and weathering. Laying of the underlayment and the shingle application must be
done together.
CORPORATE HEADQUARTERS
220 W. FOURTH STREET P.O. BOX 1404 JOPLIN, MO 64802-1404 800-641-4691
tamko.com
. l�rarrtl-oaoE
ACCREDITED
ZONSTi UCTION
TECKNOLOGIES
Report for: Tamko Building:Products, Inc.
220 W. 4th Street
Joplin, MO 64802
Attention: - Kerri Eden
Date: January 8, 2009
Product Name:
No. 30 UL
Manufacturer: Tamko
Date Received:
December 31, 2008
Source: Tamko
PRI Report No.:
TAP-219-02-01
Metro -Dade Notification No.: PRIO8124
Subject The purpose of this project was to performance properties of Tamko Building products No.
30 UL (No. 30, Type 11) asphalt felt for compliance with Florida Building Code 2004 and 2007
(HVHZ) Testing Application Standard (TAS) 110 2000: TESTING REQUIREMENTS FOR
PHYSICAL PROPERTIES OF .ROOF MEMBRANES, _INSULATION, COATINGS, AND
OTHER ROOFING COMPONENTS, Section 2.2: Roofing Components within asphalt built-up
and modified bitumen roof assemblies, and Florida Building Code 2004 and 2007, Sections
1507.2.3, 1607.3.3, 1507.5.3, and 1507.7.3: Underlayment using ASTK D 226-97a and
ASTM D 226-06: Standard) Specification forAsphalt-Saturated Organic Felt Used in Roofing
and -Waterproofing, Type II.
Tes_ t Methods: The test , methods -used included - those found in - FBC TAS 110 2000: TESTING
REQUIREMENTS FOR PHYSICAL PROPER7ES OF ROOF MEMBRANES, INSULATION,
COATINGS, AND OTHER ROOFING COMPONENTS and including: ASTM D 226: Standard
Spec cation forA. sphalt-Saturated Organic Felt Used in Roofing and Wafeiproofing,• ASTM D
146: Standard Test Methods forSampling and Testing Bitumen -Saturated Felts -and Woven
Fabrics for Roofing and Waterproofing; ASTM. D 727:. Test Method for Kerosine Number of
Roofing and Flooring Felt by the Vacuum Method.
Sample . The sample received from Tamko Building Materials on December 31, 2008 was a full factory
Description: - labded'roll of Wt.
TAP 219-02-01 - PRI Accredita Lions: [AS -ES TL-189• State of Florida TST5878• Metro -Dade o6-f 116.02- CRRC
The test results,opinions. or interpretations are based on the material supplied by thed1enL This repoitisfortheexclusiveuse ofstated
client. No reproduction orfacsimile in any form can be made without the clients permission. This reportshall nof be reproducedexcept in
full without the written.approvai of this laboratory. PRI construction Materials Technologies, LLC. assumes no responsibility normakes a
performance or warranty statement for this materiai"or products and processes containing this material in connection with this report.
PRICmMcbmLUmialsTer.WogimLLC 6408BadgerDrive Tampa.FL=10 Te.18136l-SM F=813b215840 air�1materialsl tinge icaa WehSi h0plAvsrspiitmttotn
Tamko Building Products
Laboratory Test Report for No. 30 UL Saturated'Felt
PRIO8124
Page 2 of 2
Results- of Testing:.
MethodProperty ASTM Test
5.-Ntaterials and Manufacture D 226
-.
6.1 Table
..
Result ASTM D 226 Tyll
Requirement
-Pass.¢r�=b%pttcletrei
MD
69
40-min
CMD
34
20 min
Pliability @ 77°F
D 146
Pass
No cracking
Loss on heating @ 221 -F, %
D 146
3.0
4 max
-Width of roll, in
D 146
36.2
36 t 0.7% or as agreed'
Area of roll, ft.2
D 146
217.5
216 or 432 min or as agreed'
Moisture at point of manufacture, %
D 146
3.2
4.1 max
Net mass of saturated felt, Ib/100 f?
D 146
26
26 min
Mass of saturant, lb/1-00 .fe
D 146
15.5
15 min
Mass of desaturated felt, Ib/100 fe
D 146
10.2
10 min
Ash, %
D 146
3.8
10.0 max
Saturation, %
D 146
152
150 min
6.2 Unroll @ 50 and 140'F
D 226
Pass
No cracking or sticking
6.3 Perforated felt
D 226
NA
Uniformly spaced perforations
7 Workmanship, Finish,
Appearance
D 226
Pass
Thoroughly, uniformly saturated, no
surfacing, free of visible defects
NO i s Or as agreed upon by purchaser and seller.
Statement of Compliance:
This product complies with all of -the requirements of Florida Building Code 2004 and 2007 (HVHZ) Testing
Application Standard (TAS) 110 2000: TESTING REQUIREMENTS FOR PHYSICAL PROPERTIES OF
ROOF MEMBRANES, INSULATION, COATINGS, AND OTHER ROOFING COMPONENTS, Section 2.2:
Roofing Components -within asphalt built-up and modified bitumeli roof assemblies, and Florida Building Code
2004 and-2007; Sections 1507.2.3,1507.3.3,1507:5.3,. and 1507]7.3: Underlayment using ASTM D 226-97a:
Standard Specification forAsphalt-Saturated Organic Felt Used in Roofing and Waterproofing, Type II. The
product also complies with all of the requirements of ASTM D 226-06: Standard Specification for Asphalt -
Saturated Organic Felt Used in Roofing and Waterproofing, Type 11. Limitations: None. -
Signed: -
__�_Ca '�i�
Donald C. Po olio
President
Signed:
I T. Ng
Florida Registered Pro Tonal Engineer
P. E. Number. 65034
Date:Date:
TAP-219-02-01 PRI Accreditations:lAS-ES.TL-189;State ofFlorida TST587.8 Metro-bade06-1116.02 CRRC
The test results, opinions, or interpretations are based on the material supplied by the client- This report is for the exclusive use of stated
client. No reproduction orfacsimile in any form can be made without the client's permission. This report shall not be reproduced except in
full without the written approval of this laboratory. PRI Construction Materials Technologies, LLC. assumes no responsibility nor makes a
performanceorwarranty statement for this material or products and processes containing this material in connection with this report
PRI umsmimm Materials Tectmowes, LLc. 5m Badger Drive Tampa, FLMID Tel: 813.621 SM 17= 813621-5W e-mail rmteri ttesmgWic Lmm WebRw hllpjhvww.pricmtcam
TANK®® M0930 UL PRODUCT DATA
Asphalt Saturated Organic Feltr"U
s
Manufactured in Joplin, MO, Frederick, MD,
and Green Cove Springs, FL
TAMKOO NO. 30 UL SATURATED FELT
features a tough TAMKO organic felt that is
saturated With asphalt.
' Accepted for use as an underlayment felt to be applied
over the roof deck prior to the installation of TAMKO
asphalt shingles.
a �
U.L. Built -Up Type 30 Label
ASTM D 226, Type II'
I
Roll Dimensions 72' X 36"
Coverage per roll 2 Squares =
Laying Lines 2" 4" 17" `
'All values stated as nominal
THIS PRODUCT IS SOLD "AS IS" WITHOUT WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS .FOR A.PARTICULAR PURPOSE.
l
ITAINK01
MEMO PRODUCTS
TAMKO Logo, Roofer Logo and TAMKOs
are registered trademarks of
TAMK01 Building Products, Inc.
Visit our Web Site at tamko.com
>1 f10N: Th's product canters wood dust. Mod dust has been dasgfwd as a `=wf taxman piarogen by tte: international Agency for Research
31CanoerP 1ardth&Na;znatTbxcdogyyRmgrmn. hspr«tudafsocortaasnudiZedasphait.0=ga5amspogsestooxidizedaSple,Ratxiits
�rrtssorsdruau�rodaigttirrabe�dassia;ibylARCasa"prohablstaanancamngm".O asplvJtalsvwntr'ssPoycycrcMomat1cHydrocabors
sameof%fthham been damifiedbyIARCasimovnorpmbabahmen 7hephyspJnature ofthspoductmayhdp ant any inhalation or
iartrath=ddtuisrga3p5ca@ma&ort nmvalH=vejar,oV=alfaumsichassm%Tg,9mdmgordM-gdnlgdarn5tmworkandheabVcrbL=M
nay ordsmrafe:ypmmhazadofftprodxI.Talc pecautiastoprewastbredhiigar-dartactw9hstdn.
Central District
220 West 4th St.
Joplin, MO
64801
800-641-4691
Northeast District
4500 Tamko Dr.
Frederick, MD
21701
800-368-2055
Southeast District
2300 35th St.
Tuscaloosa, AL
35401
800-228-2656
Southwest District
7910 S. Central Exp.
Dallas, TX
75216
800-443-1834
Western District
5300 East 43rd Ave.
Denver, CO
80216
800-530-8868
Information included in this product data sheet vras current at time of printing. To obtain a copy of the
most current version of this product data sheet, visit us online at tamko.com or call us at 800-641-4691.
Rev. 05/2012