HomeMy WebLinkAboutSUBMITTED PAPERSj .DATE:
RECEIPT #:
Permit #:
'1
�I �0 ,
Planning & Development Services Department
Q Building & Code Regulation Division
0 0 2300 Virginia Avenue �Q/q
Ft. Pierce, FL 34982-5652 �1FU
Tel. 772-462-1553
APPLICATION FOR ROOF PERMIT C
SEE REVERSE SIDE FOR INSTRUCTIONS O��111,
1. Location/Site Address: /o />�I IV_
2. Parcel ID Number: 13ol- /-oov --
Office Use
Only
n
TownshipRange
Ma Page
ZoningLand
Use
Ini ' s
Ir
3. Description of Project or Work Activity: RE-N6vE- .sN/Na4 Qcsy� - ��s%�9� e z� �,g ge5D,=
4. Total Roof Area (square feet): /, SO Y S- F, 5. Roof Pitch:
6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle
[ ] Tar & Gravel [ ] Modified Bitumen [x ] Other METRIC -
[,I Product Approval required for all types of Roofing Material (2 Sets)
] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information 8. Contractor Information
Name: Jd l-1tV ALzcr/
Address: io Z41vz q<
FL Reg/Cent #: C'Ceoy� 93 9
CountyCert #: �58�
City: -`T 01 EP-GE State: -'(- Business Name: 3/C', "r67 je&O c/Af -), g 67,PA/DeS
y
Zip: 349S/ Phone: 7,/a - 6 -/335? Cell Phone: &, 3- /IZ
9. Value of Construction: $ (,// Z 60
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be
done in compliance all applicabl nvs regulating construction and zoning.
JOS'EPN J-/. 13'9IkEt?' -/P-•
PRINT QUALIFIERS/OWNERS NAIME SIGIVATURLYOF QUALIFIER/OWNER.
STATE OF FLORIDA, COUNTY OF ST LOCOIC
ACKNOWLEDGED BEFORE ME THIS 7 DAY OF JANOACc( 20 BY J05EPU )4. BAKE) 49-
WHO I ERSONALLY IINOUN )4 TO ME OR HAS PRODUCED AS IDENTIFICATION
os►""ati�.: VIKKI LYNN AARON
SIGNATU F OTARY TYPE OR P NAIVE OF NOTARY ( a1=
"€ MY COMMISSION #FF007113
COMIIISSION NUMBER 66667//, "!soFM o? EXPIRES July 1, 2017
398.Ot53 Florldallotary3ervice.com
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT TVIAY
FOR INIPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COINIMENCEMENT.
Revised 4/26/2010
JOSEPH E. SMITH. RK OF THE CIRCUIT COURT - S LUCIE COUNTY
FILE # 3918491 OK 3598 PAGE 988, Recorde 24/2014 at 03:36 1
Permit No.
State of Florida County of St. Lucie
NOTICE OF COMMENCEMENT
Tax Folio No. 1301-111-0001-000-5
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,
the following information is provided in this Notice of Commencement,
Legal Description of Property: (and street address if available): 10 Danzar
1 34 39 Spanish Lakes Country Club Village
General dascription of Improvement: Re —roof
Ownsr information or lessee Information H the Lessee contracted for the improvement:
Name John T. Allen
Address 10 Danzar Fort Pierce, FL 34951
Interest in property: owner
Name and address of fee simple titleholder (if different from Owner listed above):
Wynne Building Corp. 12804 SW 122nd Avenue Miami, FL 33186-6203
Contractor's Name: Rig Lake
Contractor Address: 9 NW 16th Blvd Phone Number: 8 3-7 3-7663
Okeechobee, FL 3 972
Surety (if applicable, a copy of the payment bond is attached): Amount of bond: S
Nameandaddress: Not applicable Phone number:
Lender Name: Not applicable Phone Number:
Lender's address:
Persons within the State of Florida designated by owner upon whom notices or other documents may be served as provided by Section
713.13(1) (e)7., Florida Statutes[
Name: Phone Number:
Address:
In addition to himself or herself, Owner designates
Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes.
Phone number of person or entity designated by owner:
to receive a copy of the
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 year from the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of
my know dge and belief. /
�v
(Si ure of Owner or Lessee, or Owner's or Lessee's Authorized Officer/Director/Partner/Manager
/':'°•� VIKKI LYNN AARON
(Signatory's Title/office)
The foregoing instrument was acknowledged before me this 17 day of Jan 2014
MY COMMISSION 8FF007113
EXPIRES July 1, 2017
By John T. Allen as owner for Jahn T. Allen
Na e,oI Person Type of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed
(Signature of ota Public -State of Florida)
(Print, Type, or Stamp Commissioned Name of Notary Public)
Vikki Lynn Aaron
Personally known orproducecildentification_.
Type of Identification produced
STATE 0
ST. LU(
THIS I,�
TRUE A!
ORIGIN,
By: I '
Deputy Clerk
Date- 2014
IS A
THE a'
Property Appraiser - St.Lucie County, FL
http://www.paslc.org/paslc/prc.asp?prclid=130111100010005
Wynne Building Corp
Record: I of 5
Property Identification
Site Address:
14 LA VILLA WAY B
Sec/Town/Range:
01 :34S :39E
Map ID:
13/01 N
Zoning:
PUD
Ownership and Mailing
Owner: Wynne Building Corp
Address: 12804 SW 122nd Ave
Miami FL 33186-6203
PROPERTY RECORD CARD
<<Prev Next» SpecAssrnnt Taxes
ParcellD: 1301-111-0001-000-5
Account #: 317
Use Type: PRKG/MOBILE
City/Cnty: Saint Lucie County
Exemptions Permits Home Print
,�;CIEp�G2-:J
Legal Description
134 39 E 1/2-LESS AS IN ORS 2639-2,263: 2652-2429: 2664-2695:
2678-378,381: 2688-516: 2701-276: 302
More...
Sales Information
Assessment 2013
Total Land and Building
Date Price Code
Deed Book/Page 2013 Final:
27730500
Land Value: 9330000 Acres: 314.94
1/1/1980 950000 00
CV 0324 / 2491 Assessed:
27730500
Building Value: 18400500
11/1/1978 390000 00
CV 0307 / 1544 Ag.Credit:
0
Finished Area: 20125 SgFt
Exem pt:
Taxable:
Taxes:
561606.39
BUILDING INFORMATION
Exterior Features
View:
-
RoofCover:
-
RoofStruct: -
ExtType:
MHPK - MH Parks YearBit:
1982
Frame: -
Grade:
C - C
EffYrBlt:
1982
PrimeWall: -
StoryHght:
0010 -1 Story
No.Unfts:
1244
SecWall: -
Interior Features
BedRooms:
1
Electric:
-
PrmintWall: -
FuilBath:
0
HeatType:
-
AvgHt/Fl:
1/213ath:
0
HeatFuel:
-
Prm.Flors: -
%A/C:
0
%Heated:
0
%Sprinkled: 0
Special Features and Yard Items
Land Information
Type
Y/S Qty.
Units Qual. Cond.
YrBit.
No. Use Type
Type Measure Depth
CNC2 - CONCRETE LOW
Y 1
7200 AV
AV
1982
1 2800-PRKG/MOBILE
176 -Site 1236
CNC2 - CONCRETE LOW
Y 1
5952 AV
AV
1982
FEN1 - CHAINLINK 10
Y 1
200 AV
AV
1982
FEN4 - CHAINLINK4'
Y 1
160 AV
AV
1982
FEN6 - CHAINLINK 6'
Y 1
665 AV
AV
1982
ASP1 - ASP1 HIGH
Y 1
199380 AV
AV
1982
CSAV - COM POOL AVG
Y 1
2720 AV
AV
1982
PA01 - POOL DK-AVG
Y 1
6304 AV
AV
1982
CURB - CEMENT CURB
Y 1
695 AV
AV
1982
ASP1 - ASP1 HIGH
Y 1
360000 AV
AV
1982
1 of 2
1/19/2014 10:03 AM
Florida Building Code Online
2
Ucenteefgdentlyc llegulatefairly.
8CI5 Home I Log In I User Registration I Hot Topics j Submit Surcharge 1 Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search
,Product Approval
'USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL11651-R1 THESE PLANS AND ALL PROPOSED WORK
Revision ARE SUBJECT TO ANY CORRECTIONS
2010 REQUIRED BY FIELD INSPECTORS THAT
Approved MAY BE NECESSARY IN ORDER TO
0 COMPLY WITH ALL APPLICABLE CODES.
Gulf Coast Supply & Manufacturing, LLC.
4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352) 498-7852
ray@gulfcoastsupply.com
Ray Bowen
ray@gulfcoastsupply.com
/ ST, LUCIE COUNTY
BUILDING DIVISION
REVIEW
FOR COM
REVIEWED BY
Roofing DATE- -
PLANS AND ER IT
Metal Roofing MUST BE KEP ON JOB OR
NO INSPECTION WILL BE MADE
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Ed Evaluation Report - Hardcopy Received
Terrence E. Wolfe
PE-44923 CONOls ED FASTENERS pO�R�ATTACgHMM
Keystone Certifications, Inc. ARE THE nMr01WI0IV I I OF HE
04/12/2014 eoffm= OF WHO
Locke Bowden
r Validation Checklist - Hardcopy Received
FL11651 R1 COI Letter of Certif.odf
FL11651 R1 COI Letter of Name chanoe.odf
Standard
Year
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5... 1 /3 0/2014
4
Florida Building Code Online
Py5 t
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FM 4471
1995
FM 4471
2010
TAS 100
1995
TAS 125
2003
UL1897
2004
UL580
2006
Method 1 Option D
02/15/2012
02/23/2012
02/29/2012
04/03/2012
Summary of Products
Go to Page ........ 0 0 Page 2/ 2 0 0
FL #
IlModel, Number or Name
Description
11651.21
26 Ga. Tuff Rib
26 Ga. Tuff Rib 36" Wide over 1 x 4 Wood Pulins over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 Rl II 26 Ga. Rib overlx4 purlins NONHVHZ
details.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-164.2PSF
Created by Independent Third Party: Yes
Other:-109.25 psf @ 24" o.c. fasterner spacing. -
Evaluation Reports
164.25" psf @ 12" o.c. fastener spacing. Install per
FL11651 R1 AE 26 Ga. Rib Panel over 1x4 NON HVHZ
Roof 2010 format.pdf
manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
1.1,6541.2-2 26 Ga. Tuff Rib
26�Ga' ifiuff Rib 36" WRIe over 15/t32" P.I,ywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R1 II 26ga. Rib over .5 plywood NONHVHZ
details.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-159.2PSF
Created by Independent Third Party: Yes
Other: -69.25 psf @ 24" o.c. fastener spacing.-159.25
Evaluation Reports
psf @ 12" o.c. fastener spacing. Install per
FL11651 RI AE 26 Ga. Rib Panel over .5 Plywood NON
HVHZ Roof 2010 format.pdf
manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.23 JF26 Ga. Tuff Rib IF26
Ga. Tuff Rib Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 Rl II 26 ga Rib over .5 plywood HVHZ
Details.ndf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-159.2PSF
Created by Independent Third Party: Yes
Other: -71.75 psf @ 24" o.c. fastener spacing.-159.25
Evaluation Reports
psf @ 12" o.c. fastener spacing. Install per
FL11651 R1 AE 26 Ga. Rib Panel over .5 Plywood
HVHZ Roof 2010 format.ndf
manufacturers details. For use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.24
26 Ga. Tuff Rib
26 Ga. Tuff Rib Roof Panel over 1x4 Wood Purlins over
http://www.floridabuilding. org/prlpr_app_dtl. aspx?param--wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5... 1 /3 0/2014
Florida Building Code Online 4
Py
11
1115/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R1 II 26 Ga. Tuff Rib over 1x4 and plywood
details.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-164.2PSF
Created by Independent Third Party: Yes
Other:-106.75 psf @ 24" D.C. fastener spacing.-164.25
Evaluation Reports
psf @ 12" o.c. fastener spacing. Install per
FL11651 RI AE 26 Ga. Rib Panel over 1x4 HVHZ Roof
2010 format.odf
manufacturers details. For use in HVHZ Zones.
Created by Independent Third Party: Yes
51.25
P
29 Ga. Tuff Rib
29 Ga. Tuff Rib 36" Roof Panel Wide over 1 x 4 Wood
Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R1 II 29 GA. Rib over 1x4 ourlins NonHVHZ
Details.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-123.5PSF
Created by Independent Third Party: Yes
Other: -76.75 psf @ 24" o.c. fastener spacing. -123.5
Evaluation Reports
psf @ 24" o.c. fastener spacing. Install per
FL11651 R1 AE 29 Ga. Rib Panel over 1x4 NON HVHZf
2010 .odf
manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.26 29 Ga. Tuff Rib
29 Ga. Tuff Rib 36" Wide over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R1 II 29 Ga. Rib Panel over.5 Plywood NON
HVHZ details.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-146.OPSF
Created by Independent Third Party: Yes
Other: -71.75 psf @ 24 o.c. fastener spacing. -146.0
Evaluation Reports
psf @ 12" o.c. fastener spacing. Install per
FL11651 R1 AE 29 Ga. Rib Panel over .5 Plywood NON
HVHZ Roof 2010 .odf
manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.27 1129 Ga. Tuff Rib
29 Ga. Tuff Rib Roof Panel over 1x4 Wood Purlins
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R1 II 29 Ga. Tuff Rib over 1x4 over shingles
Details.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-101.OPSF
Created by Independent Third Party: Yes
Other: -101.0 psf @ 24" o.c. fastener spacing. Install
Evaluation Reports
per manufacturers details. Not for use in HVHZ Zones.
FL11651 R1 AE 29 Ga. Rib Panel over 1x4 NON HVHZ
Roof. odf
Created by Independent Third Party: Yes
11651.28 29 Ga. Tuff Rib
29 Ga. Tuff Rib Roof Panel over 7/16" OSB Decking
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R1 II 29 Ga. Tuff Rib over OSB details.odf
Verified By: Terrence E. Wolfe, P.E. 44923
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-116.OPSF
Evaluation Reports
Other: -22.66 psf @ 24" o.c. fastener spacing. -116.0
FL11651 R1 AE 29 Ga. Rib Panel over OSB NON HVHZ
Roof 2010 format.odf
psf @ 6" o.c. fastener spacing. Install per manufacturers
details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
Go to Page E._. 0 10 Page 2 / 2
Back Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.
*Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f]FrZeCSHgw99R5... 1 /30/2014
Asmussen Engineering Lam;
Engineering & Environmental Services
P.O. Box 1998, Okeechobee, FL. 34973-1998 Office: (863) 763-8546 Fax: (863) 467-8560
Memorandum
M, s.
Date: January 22, 2014
FILFt7
..5s' * �L• .
To: St. Lucie County Building Department
Joe Cicio — Building Official
2300 Virginia Avenue
Ft. Pierce, FL. 34982-5652
From: Loris C. Asmussen, P.E.
Subject: John Allen
10 Danzar
Fort Pierce, FL. 34951
1984 Twin Manor (24' x 61'-6") Vehicle ID No. T26315790 A/B
This memorandum is being provided to address re-roofmg of an existing 1984 mobile home located
at the address mentioned above (St. Lucie County). Proposed is Tuff Rib Roof Paneling (26GA
metal — FL 11651.22R1) as a replacement to the originally manufactured roof, with Tamko
Underlayments (FL 12328-R2). Attached are product approvals for this product and underlayment
(including attachment methodology for the rib panels, as well as, underlayment). The roof product
is manufactured by Gulf Coast Supply & Manufacturing, Inc. The product approval for the metal
roof (#I 1651.22R1) is attached for your review and approval (Engineer Evaluator Terrence E.
Wolfe, P.E. and Validated by Locke Bowden, P.E.).
Based on my review of this proposed project, including product approvals and loads for which the
above -referenced structure will be exposed to at this location in St. Lucie County (160 mph 3-
second gust and exposure "C"), the project is found to be in substantial compliance with the 2010
Florida Building Code.
Please contact my office at (863) 763-8546 with any additional comments or questions regarding
this structure. Thanks for your attention to this matter.
Sincerely,
btJlJ�� �v
Loris C. Asmussen, P.E.
Principle
Enclosed Correspondence
C: Allen File
R l A
CUP
rForcengineering & Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Product Evaluation Report
GULF COAST SUPPLY & MANUFACTURING, LLC.
26 Go. Tuff Rib Roof Panel over 15132" Plywood
Florida Product Approval # 11651.22 R1
Florida Building Code 2010
Per Rule 9N-3
Method: 1—D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 9N-3.005(1)(d)
NON HVHZ
Product Manufacturer:
GULF COAST SUPPLY & MANUFACTURING, I.I.C.
4020 S.W. 449`h Street
Horseshoe Beach, Florida 32648
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID:1920
Validator:
Locke Bowden, P.E., FL #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1-4
{{I IIIjr,
��I
0
c E N S
No. 4 94 '
ma's' STATE OF
FLORI�g' �4,
susorn� �� Fs • • 1 ��
Nv,��
FL# 11651.22 R1
February 22, 2012
COPY
(' V0 FILE
Force Engineering & Vesting Inc.
19530 Ramblewood Drive
Huinble,TX 77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2010, Sections 1504.3.2.
Product Description: Tuff Rib, %" Rib Roof Panel, Min. 26 Ga. Steel, 36" Wide, through fastened roof
panel over 15/32" Plywood decking. Non -Structural Application.
Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2010 Section 1507.4.3. Paint finish optional
Yield Strength: Min. 80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2010, Section 1507.4.3.
Panel Dimension(s): Thickness: 0.018S" min.
Width: 36"
Rib Height: V major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener:
Substrate Description:
Design Uplift Pressures:
FL# 11651.22 R1
#9-1S x 1-1/2" HWH Woodgrip with sealing washing or approved equal
" minimum penetration through plywood
Corrosion Resistance: Per Florida Building Code 2010, Section 1506.6, 1507.4.4
Min. 15/32" thick, APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside the scope of this
evaluation. Must be designed in accordance w/ Florida Building Code 2010.
Table "A"
Maximum Total Uplift Design Pressure:
Erg; ps
159.25 psf
Fastener Pattern:
6.5"-2.5"-6.S"-2.5"-
6.5"-2.5"-6.5"
Fastener Spacing:
24" Q.
12" O.C.
"Design Pressure includes a Safety Factor = 2.0.
*.'* { { 11111114F
0
No.44�9
STATE OF : ac
NAL
February 22, 2012
Force Engineering & Testing Inc.
19530 Ramblewood Drive
Hunible,TX 77338
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2010, Section 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2010, as relates to Rule 9N-3.
Performance Standards: The product described herein has demonstrated compliance with:
I-1 UL 580-06 - Test for Uplift Resistance of Roof Assemblies
Ll UL 1897-04 - Uplift Test for Roof Covering Systems
Reference Data: 1. UL 580-94 / 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 117-0062T-07A, B, Dated 02/19/2007
2. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc.
(FBC Organization # ANE ID: 1920)
Test Standard Equivalency:
1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard.
Quality Assurance Entity:
The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 9N-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range:
Minimum Slope shall comply with Florida Building Code 2010, including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
installation:
Install per manufacturer's recommended details.
Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2010 Section
1507.4.5.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
FL# 11651.22 R1
,,,`{{{{Irlfll��I
C E N S �. �.t► ,,i
• No. 449
a • STATE OF
t
February 22, 2012
COPY
Force Engineering & Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Design Procedure: Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2010 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2010
Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
FL# 11651.22 R1
I
J.
�. • ,
No. 44D
STATE OF ; ar
AL 0 R 1 OOWM
,4,1
1 1N 111:►15,,
February 22, 2012
- 5130/13 =
BCIS Home La -1
FloridaBuilding .Code Online -
g n user Registration Hot Topics Submit Surcharge Stats & Fads
Wsines
PrDfQJJjV�
4.0--
PmdurtrouuR:Publicsser I
A2RMt t 6irnu > Product or Aoolication Search > p PPt[catior list
Search Criteria
4P
'
Pobbmtions Fat staff aeis site flap
Links search
Refine Search
Code Version
2010 FL-1
Application Type
ALL Product Manufacturer
12328.10
Cate o nr
g
ALL Subcategory
ALL
Application Status
ALL Compliance Method
ALL
ALL
Quality Assurance EntityALL
ALL Quality Assurance Entity Contract Expired
Product Model, Nurnber or Name ALL Product Description
ALL
Approved for use in HVHZ
ALL Approved for use outside HVHZ
ALL
Impact Resistant
ALL Design Pressure
ALL
Other
ALL
ALL
Search Results - Applications
Tub:.
Manufartur=_r
ii r7liCir3i-t3{i
.�G'3YF35
FL12328-R2 I Revision
t
TAMKO Building Products, Inc. Robert ]. M. Niendnen, PE
f
Fiister� 3
! FL#: FL12328.10 1 (203) 262-9245
Approved
f
I Model: No. 30 UL,
(
!
! Description: Asphalt saturated organic felt
+
1 Category: Roofing
j Subcategory: Undedayments 1
FL12328-113 Editorial Change 1
i
TAMKO Building Products, Inc. Robert J. M. Nieminen, PE !Pending FBC Approval
1
FL :: 0 f (203) 262-9245
Model: No. 30
�
Description: Asphalt saturated organic felt
I
1
Category: Roofing ff
Subcategory: Underlayments
;Approved by DBPR- Approvals by DBPR
shall be reviewed and ratified by the POC and/ar the Commission tf necessary.
Contact Us :: �40 North Monroe Sheet Taliaha a Ff 32399 Phosre- 850-497-t024
The State of Florida is an AA/EEO employer. _Canvrioht 2007-�O1D State of Flodda Privacy 4tateme t --
.. AGcessibilhv Statement :: Refund'Statement
UnderFlodda law email addresses are public records. If you do not want youre-mall address released In response to a publirrewtds request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact cords request,
nots 'Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, FS. must provide the Department with an email address if
they have one. The emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee
under Chapter455, F S., please dick here .
Product APProval Accepts:
a WE.t� EJ
_ccuravr n .
M.
mAmu.iloiidaWIcOng.org/pr/pri-pppjsLaspx
1/1
991169ING PRODUCTS
UNDERLAYMENT: An underlayment consisting of asphalt saturated felt must be
applied over the entire deck before the installation of TA 4KO shingles. Apply the felt
when the deck is dry. On roof decks 4 in. per foot and greater apply the felt parallel to the
eaves lapping each course of the felt over the lower course at least 2 in. Where ends join,
lap the felt 4 in. If left exposed, the underlayment felt may be adversely affected by
moisture and weathering. Laying of the underlayment and the shingle application must be
done together.
CORPORATE HEADQUARTERS
220 W. FOURTH STREET P.O. BOX 1404 JOPLIN, MO 64802-1404 800-641-4691
tamko.com
reatin_nane _ .•C .
ON
ACCRBDITEaAMM
iTRUCTiON MAEra
TECHNOLOGIES�
■�
Report for; Tamko Building -Products, Inc. Date: January 8, 2009
220 W. 4th Street
Joplin, MO 64802
Attention: Kerri-Eden
Product Name: No. 30 UL Manufacturer: Tamko
Date Received: December 31, 2008 -Source: T mko
PRI Report No.: TAP-219-02-01 Metro -Dade Notiijlcation No.: PRiO8124
i
Subject- The purpose of this project was to performance properties of Ta ko Building Products No.
3.0 UL (No_ 30, Type Il) asphalt feitfor compliance with Florida Building Code 2004 and 2007
(HVH2) Testing Application Standard (TAB) 110 2000: TESTING REQUIREMENTS FOR
PHYSICAL PROPERTIES OF ROOF MEMBRANES, INSULATION, COATINGS, AND
OTHER ROOFING COMPONENTS, Section 2.2: Roofing Components within asphalt built-up
and modified bitumen roof assemblies, and Florida Building Code 2004 and 2007, Sections
1507.2.3, 1607.3.3, 1507.5.3, and 1507.7.3: Underlayment using ASTM- D 226 97a and
ASTM D 226-06: Standard) Specification forAsphalt-Saturated Organic Felt Used in Roofing
and Waterproofing, Type 11.
Test Methods: The test - methods used included - those found in • FBC TAB 110-2000: TESTING
REQUIREMENTS FORPHYSICAL-PROPER77ESOFROOFMEMBRANES, INSULATION,
COATINGS, AND OTHER ROOFING COMPONENTSand including: ASTM D 226: Standard
Specification for .Asphalt -Saturated Organic Felt Used in Roofing and Waterproofing,• ASTM D
146: Standard Test Methods for Sampling and Testing Bitumen -Saturated Felts and Woven
Fabrics for Roofng and Waterproofing; ASTM. D 727.. Test Method for Kerosine Number of
Roofing and Flooring Felt by the Vacuum Method.
Sample The sample received from.Tamko Building Materials on December 31, 2008 was a full factory
Description: labded, roll of felt.
rAt-279.02-01 - PRI AccreditaHons:lAS-ESTL-189: state ofFlormaTST5878-mehn-Uade.0641:18. CRRC
The test results, opinions, or interpretations are based on the matertatsupplied by the client This report is;for the exclusive use of stated
client. No reproduction or facsimile in any farm can be made without the client's permission. This report shall not be reproduced.except in
full wwithoutthewMen-approvatofthislaboratory. PRI Construction Materials Technologies,LLC_assumesnorespons�il�ynormakesa
performance orwarranty statement for this matedaror products and processes containing this material in' connection with this report.
PRICMMXSMMat ftTwhW-ogkS,LLC. s4 BackE D&e TwWa FLMsin TW613_6ztsm F=81 6z1,Wq e.ma7maWdse rng cean webs nnRrlw"0piticOrt►
Tamko Building Products
Laboratory Test Report for No. 30 UL Satuiated-Felt -
PRI08124
Page 2 of 2
ILE -C(Opy
MD
69
40.min
CMD
34
20 min
Pliability @ 77-F
D 146
Pass
No cracking
Loss on heating @ 221 OF, %
D 146
3.0
4 max
Width of roll, in
D 146
36.2
36 t 0.7% or as agreed'
Area of roll, ft 2
D 146
217.5
216or 432 minor as agreed'
Moisture at point of manufacture, %
D 146
3.2
4.1 max
Net mass of saturated felt, Ib/100 ftz
D 146
26
26 min
Mass of saturant, Ib1100 ft D
146
15.5
15 min
Mass of desaturated felt, Ib/100 ff
D 146
10.2
10 min
Ash, %
D 146
3.8
10.0 max
Saturation, %
D 146
152
150 min
6.2 Unroll @ 50 andE140-FE
*Perforated
D 226
Pass
No cracking or sticking
6.3 felt
D 226
NA
Uniformly spaced perforations
7 Workmanship, Finish,
A
Appearance
D 226
Pas,
Thoroughly, uniformly saturated, no
Nntp 11• ()r ne a reed b
surfacing, free of visible defects
g upon y purchaser and seller.
Statement of Compliance:
This product complies with all of the requirements of Florida Building Code 2004 and 2007 (HVHZ) Testing
Application Standard (TAS) 110 2000: TESTING REQUIREMENTS FOR PHYSICAL PROPERTIES OF
ROOF MEMBRANES, INSULATION, COATINGS, AND OTHER ROOFING COMPONENTS, Section 2.2:
Roofing Components -within -asphalt built-up and modified bitume roof assemblies, and Florida Building Code
2004 and 2t307; Sections 1507.2.3,1507.3:3,1507.5.3,. and 150717.3: Underlayment using ASTM D 226-97a
Standard Specification lbrAsphalt-Saturated Organic Felt Used in Roofing and Waterproofing, Type 11. The
product also complies with all of the requirements of ASTM D 226-06: Standard Specification forAsphaft-
Saturated Organic Felt Used in Roofing and Waterproofing, Type 11. Limitations: None.
Signed:- -OZ
Donald C. Po olio
President
Signed:
Duc T. Ng
Florida Registered P Tonal Engineer
P. E. Number. 65034
Date: L% 619 Date:
TAP 219-02-01
PRI Accreditadons: [AS -ES TL-189• State of Florida TST587.8• Metro -!Jade 06-1116.0 . CRRC
The test results, opinions. or interpretations are based on the material supplied by the client This report is for the exclusive use of stated
client. No reproduction orfacsimile in any form can be made without the crieffs permission. This report shall not be reproduced except in
full without the written approval of this laboratory. PRI Construction Materials Technologies, LLC. assumes no responsbilitynor makes a
performance or warranty statement for this material or products and processes containing this material in connection with this report
Prd ConsinxUon 6larefats Techndogles, tLC 6408 badger Drive Tanya. FLM510 Tel: 813821S7n Fax 8138Z1.5m e4ffi9 rraterizktes6t g&rkmLmm- WebML-httjW-A w.K=ntWM
trig,
TA KOO sW 9� -` COPRODUCT DATA
Asphalt Saturated Organic Felt
Manufactured in Joplin, MO, Frederick, MD,
and Green Cove Springs, FL
i
TAMKO9 NO. 30 UL SATURATED FELT
features a tough TAMKO organic felt that is
saturated with asphalt.
Hccepteo for use as an underlayment felt to be applied
over the roof deck prior to the installation of TAMKO j
asphalt shingles.
U.L. Built -Up Type 30 Label
ASTM D 226, Type If
Roll Dimensions 72' X 36"
Coverage per roll 2 Squares _
Laying Lines 2", 4", 17"
'All values stated as nominal -..
THIS PRODUCT IS SOLD "AS IS" WITHOUT WARRANTIES, EXPRESSED OR
.IMPLIED, .INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
Visit our Web Site at tamko.com
i
CAUTION: 7hs product oanf is oval dusL Mod dust his ►a m as a -kr=vn" tartar CafakVen %1 tf$ Interr t Agauy for Res r
cn Canoe j1ARQ aid the Nairn TagcobgyAugam.1T- Pro kid also caf0m =&ad isphal Occto mcd¢ed aojaja, ad 7s
arisatscka�9raa`+rgtmebemdamed yARCesa`prabableFranaic O):�dasOaftalsow[W.PalvcrcAromatbHydvcebons
xrneof%Mtchhweb5End byIAOCastm,.norprobabarnr'tranarcvwgmmThepVecalria.Lmoftffsproductrnalhdpfin3arryir]mbkna
i�lhz�dduzngapp-�4onard/arxnaaLHatieue4f3ry�fac�sudiassatcaS.grJdrgor T
naYhae eff>°i1Nr hgonord3nrdopmmharadarft roductTak^aera,to d �d `6cnuCkz7df=arng[rbtyni7g
pevert(3e
aflt"ga rdmrdac tv.9hsKh
AINUCentral
District 220 West 4th St.
Joplin, MO 1 64801
800-641-4691
BUILDING ]PRODUCTS
Northeast District 4500 Tamko Dr.
Southeast District 2300 35th St.
Frederick, MD 21701
Tuscaloosa, AL 35401
800-368-2055
Southwest District 7910 S. Central Exp.
Dallas, TX 75216
800-228-2656
800-443-1834
TAMKO Logo, Roofer Logo and TAMK05
Western District 5300 East 43rd Ave.
Denver, CO 80216
800-530-8868
are registered trademarks of
TAMKO' Building Products, In~
Information included in this product data sheet %vas current
at time of printing. To obtain a copy of
the
most current version of this product data sheet, visit us onrne at tamko.com or ca0 us at 800-641-469t.
Rev. 05l2012