Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSe Date: Fee Due: Planning & Development Services Building & Code Regulations Division scC 2300 Virginia Ave. NEB Fort Pierce, FL 34982 St 4 (772)462-1553 itC/e county SPECIALTY PERMIT APPLICATION ❑ Electrical ❑ Plumbing ® HVAC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding Seepage 2 for instructions and ditio alp nvork uired for specialty permits 1. Location/Site Address: I� 2. Parcel ID Number: Office Use Section Township Range Map Page Zoning Land Use Initials Only 3. Complete Description of Project or Work: LIKE FOR LIKE CHANGE OUT 4. Owne jnnformaIt ' / Name: /� (0flo. i Address: City: Zip: 6. Value of Construction: 5. Contractors Information FL Reg/Cert #: CAD.01 6 4 4 6 County Cert#: 8283 State: Business Name: SEA COAST A/C Phone: Phone: 4 6 6— 2 4 0 0 Fa s— OWNER'S AFFIDAVIT: I certify that all of the information contained in this compliance with all applicable laws regulating con: JOHN V LANGEL < 466-3053 that all work will be done in PRINT OWNER OR CONTRACTOR NAME SIGNAT F OWNER CONTRACTOR STATE OF FLORIDA, COUNTY OF ST . LUCIE A CKNOWLEDGED�KNOW E THIS DAY OF 20 BY JOHN V LANGEL ERS�'P ONALLE X OR WHO HAS PRODUCED ALw_i 1FICA SIGNAT E OF OTA COMMISSI MBE TYPE OR PRINT NAME OF NOTARY IVUTARY PUBLIC iSTATF� OF FLOROpA Comm; M921924 Expires 8/30/2014 NOTICE TO OWNER: FAILURE' TO RECORD A� NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS YOUR PROPERTY.- YOUPROPERTY.- IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE:RECORDING:YOUR.NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH: CONTRACT"UNDER.S7500.00 Revised 04/26/2010 ®, This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. 54- ?_ NX ` lrfoo�i =rct-wo 41= I AHRI Certified Reference Number: 5924359 Date: 1/22/2014 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: GSX160601F* Indoor Unit Model Number: AVPTC60D14A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONIN Series name: Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): EER Rating (Cooling): SEER Rating, (Cooling): IEER Rating (Cooling): 54000 13.00 16.00 * Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate DISCLAIMER ' AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents ofthis Certificate may not, iniwhole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, "ImpAir-Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on ENE ILI and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2013 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130348922370271795 ND • r -+ wrightsoft, Project Summary Entire House QUICKI CALLS, INC. 317 ST LUCIE LN., FT. PIERCE, FL34946 Phone:772-466-6799 Fax 772466-6796 Email: QUICKC4LCS@AOL.COM For. IRENE HALFORD 8I912 FIRST TREE RD., PORT ST. LUCIE,. FL Notes: Desiqn Information Weather. Fort Pierce, FL, US Job: Date: Jan 22, I By( t� Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 6F Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21667 Btuh Structure 29436 Btuh Ducts 9609 Btuh Ducts 12217 Btuh Central vent (60 cfm) 1852 Btuh Central vent ,(60 cfm) 992 Btuh Humidification 0 Btuh Blower 0 Btuh Piping, 0 Btuh Equipment load 33128 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 40514 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality, Average Fireplaces 0 Structure 2917 Btuh Ducts 4009 Btuh Heating Coolingg Central vent (60.cfm) 2514 Btuh Area (ft2) 1 2215 2215 Equipment latent load 9441 Btuh Volume (ft') 19008 19008 Air changes/hour 0.32 0.16 Equipment total load 49955 Stuh E:quiv; AVF (cfm) 101 51 Req. total capacity at 0.70 SHR 4.8 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg. Trade Trade Model Cond GSX16060. AHRI ref Coil AVPTC60D14 AHRI ref 5924359 Efficiency 100 EFF Efficiency 12.5 EER, 16 SEER Heating input 9.2 kW Sensible cooling 37800 Btuh Heating output 31259 Btuh Latent cooling 16200 Btuh Temperature rise 15 °F Total cooling 54000 Btuh Actual airflow 1867 cfm Actual airflow 1867 cfm Air flow factor 0.060 cfm/Btuh Airflow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual, J 8th Ed. t wrightsoft, ,RightSulte® Universal 201313.0.01 RSUG8101 2014-Jan-22 16:24:24 Page 1 .odM ...eskDocumentslWrlghtsoft WAQHAL�ORD, IRENE.rup Calo= MJ6 Front Door facets N 01/22/2014 14:43 772466:� �s SEACOAST AC PAGE 62 Date: Jr 0 1 2Jt+'ee D lj�'t-,:;ki�;:,•�..�;. .;^ i C] Electrical ❑ PI'u 13 Shed I:1 Det See pager 2 for ins 1. I,00tion/Site Akdd Tess: 2. Parcel ID Nurnberg , Recei Permit # Planning & D6velopment Semices Bitilding & Code Regulations :Division 2300 Virginia Ave, Fort Fierce, FL 34482 (772)462-1553 SPECIALTY PERMIT APPLI<CATIOiri Ilbing M HVAC ❑ Fence olition ❑ Gas ❑ Siding ustiuras and dit u al pa nvork rr'red for specialty .pern its Township Range Map P)Ige Toning Land Use Office Ilse Section Only 3. Complete Description of Prgje It or Works LIRE FOR LIKE CHANGE OUT r— — — It i_ it �v 4. Ownep nforMA ' n Name: 1 A,driress: 11 City: zip'. 6. Value of Construction: $ 5. Contractors In.forniation P U Iteg/Cert #: CA001 6 4 4 6 County Cert#: 8283 State: Business Name: SEA COAST A/C Phone: P11one:466--2400 Fax: 456-3053 �-- 11 VwNER'S nr'1 T.nAVTT: I certify that all Of the infOrmaticm contained in this compliance With all applicable laws rcguiating con: ►LAN PRINT OWNER OR CONTRACTOR INAME-I SICNATIJ'Rl STATE. Of FLORIDtN. COUNTY OF Srp LUCIE AC: NOWI.MSAED : METT-Ifs DAY Q(- ' 20 kR50Nai,1.Y KN li O2i EM.QRQR WHO HAS PRODUCED is c freciald that all work will be dpno- OWNPRpJIR CONTRACTOR By JOHN V LANGEL 5 ]) NTIFIGn 1 I.0 nee t /it�l" PU661C a sTgT �oa,r, 51GNnrT- E r�r OTA TYPT pR l'RLNT �IA,yL OFNq'('ARY �tQ29t3�q} res 8f3p�4 COMMISSI ,MT3ER NOTICE TO OWNER: FAfi,L'RE TO RECOR,I) A- NOTICE OF COMMENCEMENT AIAY 119SULT IN YOUR PAYING TWICE FOR IMPROVEARUNTS TO YOUR: PROPERTY.. It' YOU INTEND TO OBTAIN FTNANCTNG, CONSULT WITM YOUR LENDER. OR AN ATTORNEY BEFORE. RECORDIN(;-YO[JR NOTICE Oi� COMMENCrjWENT- EXEMPT; A/C-TlEATREPLACEMENT WITI'TCON•TRAcr UNDRR-57500.0f) Reviled IM26/21110