Loading...
HomeMy WebLinkAboutREVISIONSOFFICE USE ONLY: DATE FILED: .3.4. % REVISION FEE: 1. Is "CANNED 3 Y PERMIT # �f. LUCIe COur�ij'' RECEIPT# PLANNING \ DEVELOPIV 1. i iYr ti BUILDING ' CODE ` J • IIl ■ f y IVIRGIN li FORT .�T• �� tip >> � �. .?` ,�� APPLICATION FOR BUILD I PROJECTINF ADDRESS: Cat 2. DETAILED DESCRIPTION OF PROJECT RF.VF910NS: 3. 4. 5. lr RTwj CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: _ BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTEWE): OWNER/BUILDER INFORMATION: NAME: IQL(1 ADDRESS: CITY: PHONE: 3110 o ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9/23/09 Revised 04/26/2010 ST. LUCIE COUNTY CERT. #: STATE: FAX: STATE: STATE: FAX: FAX: ZIP: ZIP: Florida Building Code Online Page 1 of 2 j1t u 1. 7 twx i • e 1 B 0_, tl Flol➢da Departmentof BCIS Home j Log In ; User Registration Hot Topics Submit Surcharge i Stats ikFacts i Publications 1 FBC Staff I BCIS Site Map ; Links I search I BusinesProducts 4USER: Professi pal PublicAUproval Regulation ArJJ! Product Aooroval Menu > Product or Application search > Application List > Application Detail FL # FL1654-R12 COPY Application Type Revision ""ILE Code Version 2010 Application Status Approved Comments ? Archived ❑ _ / � ( � D� �. Il \-111 Product Manufacturer POLYGLASS USA Address/Phone/Email 150 Lyon Drive Fernley, NV 89408 (570) 384-1230 Ext 242 jakins@polyglass.com Authorized Signature James Akins jakins@polyglass.com Emu Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive Fernley, NV 98408 (602) 363-7139 stevew@polyglass.com Quality Assurance Representative James Akins Address/Phone/Email 555 Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800)894-4563 jakins@polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) ST LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANCE REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer IA Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 UL LLC 08/08/2015 John W. Knezevich, PE 146 Validation Checklist - Hardcopy Received FL1654 R12 COI Trinity ERD CI - Nieminen - 2013.odf standard Year ASTM D6163 2000 ASTM D6164 2005 ASTM D6222 2002 ASTM D6509 2000 FM 4470 1992 FM 4474 2004 http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFg... 3/4/2014 Florida Building Code Online Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 08/21/2013 08/26/2013 09/08/2013 10/18/2013 FL # Model, Number or Name Description 1654.1 Polyglass SBS and APP Modified SBS and APP modified bitumen roof systems Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL1G54 R12 II Al ER082113FINAL POLYGLASS MODBIT FL1654- R12.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this application Evaluation Reports relates to one particular assembly over concrete FL1654 R12 AE ER082113FINAL POLYGLASS MODBIT FL1654- R12.pdf deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer to ER, Section 5 for other Created by Independent Third Party: Yes Limits of Use. Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32329 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine IF you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 1= ® cj=4 M sceuritYAi rl itics, http://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFg... 3/4/2014 0 S I ERE EVALUATION REPORT Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 89408 EXTERIOR RESEARCH & DESIGN., LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report P9290.02.08-1110 FL1654-R12 Date of Issuance: 02/ 11/ 2008 Revision 10: 08/21/2013 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 31-page Appendix. Prepared by: The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 08/21/2013 This does not serve as an electronically signed Robert J.M. Nieminen P.E. "�—:. document. Signed, sealed hardmpies have been at i ry0'.a- �r' transmitted to the Product Approval Administrator and Florida Registration No. 59166, Florida DCA ANE1983 �`j'""""' " to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. `?-..'TRINITY ;ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of,Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2004 1504.7 Impact FM 4470 1992 1507.11.2 Physical Properties ASTM D6163 2000 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2002 1507.11.2 Physical Properties ASTM D6509 2000 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties P10490.10.08-2 10/30/2008 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P30540.11.09-111 11/30/2009 ERD (TST6049) FM 4470/4474 P305SO.12.09 12/02/2009 ERD (TST6049) Physical Properties P33960.12.10 12/30/2010 ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011 ERD (TST6049) Physical Properties P37590.03.13-3A 03/06/2013 ERD (TST6049) FM 4470/4474 P39680.03.13 03/04/2013 ERD (TST6049) Physical Properties P37590.03.13-1-R1 06/26/2013 ERD (TST6049) Physical Properties P37590.03.13-2-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-2 07/01/2013 ERD (TST6049) Physical Properties P37590.03.13-5-111 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-1 07/02/2013 ERD (TST6049) FM 4470/4474 P41630.08.13 08/06/2013 FM Approvals (TST1867) FM 4470 2W7A7.AM 08/04/1994 FM Approvals (TST1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3006646 01/04/2000 FM Approvals (TST1867) FM 4470 3001334 01/25/2000 FM Approvals (TST1867) FM 4470 3001334 02/15/2000 FM Approvals (TST1867) FM 4470 3000857 01/12/2000 FM Approvals (TST1867) FM 4470 3004091 01/12/2000 FM Approvals (TST1867) FM 4470 3006115 05/02/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3007170 01/13/2004 FM Approvals (TST1867) FM 4470 3019317 06/30/2004 FM Approvals (TST1867) FM 4470 3020703 07/30/2004 FM Approvals (TST1867) FM 4470/4474 3018332 01/31/2006 FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals (TST1867) FM 4470/4474 3024594 05/23/2006 FM Approvals (TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals (TST1867) FM 4470/4474 3030668 09/12/2007 FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009 PRI (TST5878) Physical Properties PUSA-062-02-01 12/04/2007 Exterior Research and Design, LLC. Evaluation Report P9290.02.08-1110 Certificate of Authorization #9503 FL1654-R12 Revision 10: 08/21/2013 Page 2of5 S Entity PRI(TST5878) PRI(TST5878) PRI(TST5878) Miami -Dade (CER1592) Miami -Dade (CER1592) UL LLC (QUA9625) 4. PRODUCT DESCRIPTION: Examination Physical Properties Physical Properties Physical Properties HVHZ Compliance Proposal for Review Quality Control rt ...w . F TII� Reference Date PUSA-061-02-02 01/28/2008 PUSA-064-02-02 02/27/2008 PUSA-062-02-02 12/04/2008 Various NOAs Various 10-0823 10/12/2010 Service Confirmation, R14571 Exp. 08/08/2015 This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. Table 1: Roll -Goods for Polyglass Modified Bitumen Roof Systems Type Product Specification Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A II Polyglass APP Base ASTM D6509 N/A N/A SBS Membranes Elastobase ASTM D6163 S I Elastoflex V ASTM D6163 S I Elastoflex SA V Base ASTM D6163, Table 2 S I Elastoflex SA V FR Base ASTM D6163, Table 2 S I Elastoflex SA V Plus ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastobase Poly ASTM D6164 S I Elastoflex S6 ASTM D6164 S I Elastoflex S6 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G I Polyfresko MOP ASTM D6164 S I Polyfresko MOP FR ASTM D6164 S I Elastoshield TS G ASTM D6164 G I Elastoshield TS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Polyfresko SBS SAP ASTM D6164 S I Polyfresko SBS SAP FR ASTM D6164 S I APP Membranes Polyflex ASTM D6222 S I Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G I Polyfresko Torch ASTM D6222 S I Polyfresko Torch FR ASTM D6222 S I Polybond ASTM D6222 S I Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G I Polyflex SA P FR ASTM D6222 G I Polyfresko APP SAP ASTM D6222 S I Polyfresko APP SAP FR ASTM D6222 S I Polykool ASTM D6222 S I Polybianko ASTM D6222 S I Exterior Research and Design, LLC. Evaluation Report P9290.02.08-R10 Certificate ofAuthorization #9503 FL1654-R12 Revision 10: 08/21/2013 Page 3 of 5 :7 S 5. LIMITATIONS: X _ tTRINITY I ERD 5.1 This Evaluation Report is not for use in HVHZ. 5.2 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.3 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.4 Unless otherwise noted in Appendix 1, roof decking and its attachment shall be specified and installed to meet project design criteria to the satisfaction of the AHJ. 5.5 For recover installations, the existing roof shall be examined in accordance with FBC 1510. 5.6 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 5.7 For fully -adhered insulation, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.8 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 5.9 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124 shall be conductedon mock-ups of the proposed new roof assembly. 5.10 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124. 5.11 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind speed shall be determined from FBC Figure 1609. 5.12 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Polyglass Modified Bitumen roof systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. Exterior Research and Design, LLC. Evaluation Report P9290.02.08-1110 Certificate of Authorization #9503 FL1654-R12 Revision 10. 08/21/2013 Page 4 of 5 6.3 Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on . the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating; ➢ PG300 Fibered Roof Coating or Mule -Hide 102 Fibrated Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating; ➢ PG700 White Reflective Roof Coating; ➢ PG800 Non-Fibered Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Fibrated; ➢ PG850 Fibered Asphalt Emulsion Roof Coating or Mule -Hide 301 Emulsion Fibrated; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating or Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating; ➢ Polybrite 70 White Elastomeric Roof Coating. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA requirements 9. QUALITY ASSURANCE ENTITY: UL LLC - QUA9625; (314) 578-3406, k.chancellor@us.ul.com - THE 31-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report P9290.02.08-1110 FL1654-R12 Revision 10: 08/21/2013 Page 5 of 5 so • I� Tyaf �i T I I Eta TABLE 3E: WOOD DECKS — NEW CONSTRUCTION op. REROOF (TEAR -OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck (See Note 1) Base Sheet — Roof Cover MDP Base Fasten Attach Ply Cap No. (Psf) Min. 19/32-Inch plywood at max. 24-inch spans 32 ga., 1-5/8-Inch diameter tin 6-Inch o.c. In 4-Inch lap and 6- (Optional) One or more BP -AA SBS- SBS-AA,, W-40 attached 6-inch o.c, with Elastobase or Elastobase Poly caps with it ga, annular ring inch o.c. in four, equally AA, SBS-TA or APP- SBS-TA, -112.5 #8 screws shank nails spaced, staggered center rows TA APP-TA Min. -Inch plywood 32 ga., 1-5/8-Inch diameter tin (Optional) One or more SBS-SA (no SBS-SA, at maxx.. 24-Inch spans Elastobase or Elastobase Poly with caps with 11 ga. annular ring 6-Inch o.c, in 4-inch lap and b- Elastoflex SA V Base APP-SA, W-41 attached 6-inch o.c. with poly top surface shank nails. Note; Tin caps are Inch o.c. In four, equally or Elastoflex SA V FR SBS-TA or -112.5 #8 screws to be primed with PG100 or spaced, staggered center rows Base), SBS-TA or APP-TA ASTM D41 primer. APP-TA Min. 15/32-inch thick OMG #12 Standard Roofgrip or exterior grade plywood OMG #14 Heavy Duty (min. 1- 6-inch o.c. at 4-Inch lap and 6- W-42 attached per Code to meet Polyglass APP Base 5/8-Inch long) with OMG 3" inch o.c. In five, equally (Optional) APP-TA APP-TA -120.0 pressure requirements. Round Metal Plates or OMG Flat spaced, staggered center rows Bottom Metal Plates Min. 15/32-inch thick OMG #12 Standard Roofgrip or exterior grade plywood OMG #14 Heavy Duty (min. 1- 6-inch o.c, at 4-inch lap and 6- (Optional) BP -AA, SBS-AA, W-43 attached per Code to meet Elastobase (with sand top surface) 5/8-Inch long) with OMG 3" Inch o.c. in five, equally SBS-AA, SBS-TA or SBS-TA or -120.0 pressure requirements, Round Metal Plates or OMG Flat spaced, staggered center rows APP-TA APP-TA Bottom Metal Plates Min. 15/32-Inch thick exterior grade plywood Trufast #12 DP or Trufast #14 6-Inch o.c. at 4-Inch lap and 6- (Optional) BP -AA or W 44 attached per Code to meet Elastobase (with sand top surface) HD (min. 1-5/8-inch long) with Inch o.c. in five, equally SBS-AA SBS-AA -120.0 pressure requirements, Trufast 3" Metal Insulation Plates spaced, staggered center rows TABLE 1F: WOOD DECKS — NEW CONSTRUCTION oR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System No. Deck (See Note i) Primer Roof Cover MDP Joint Treatment Base Ply Cap (Psf) Min. 19/32-inch plywood at - W-45 i max. 24-inch spans attached (Optional) PG100 None SBS-SA (Optional) SBS-SA, SBS-SA, APP-SA, 90.0 6-Inch o.c. with 8d ring shank SBS-TA or APP-TA SBS-TA or APP-TA nails Min. 15/32-inch plywood at Plywood joints are covered with 4-inch wide strips Elastoflex SA V (Optional) SBS-SA, SBS-SA, APP-SA, W-46 max. 24-Inch spans attached (Optional) PG100 of Elastoflex SA V Plus, rolled Into lace to create p Base or Elastoflex -97.5 6-inch o.c, with *12 screws continuous bond. SA V FR Base SBS-TA or APP-TA SBS-TA or APP-TA Min. 15/32-inch plywood at Plywood joints are covered with 4-Inch wide strips Elastoflex SA V Plus (Optional) SBS-SA, ion l) SBS-SA, APP-SA, APP-SA W-47 max. 24-inch spans attached (Optional) PG100 of Elastoflex SA V Plus, rolled Into lace to create or Elastoflex SA V -135.0 6-inch o.c. with #12 screws continuous bond. Plus FR SBS APP-TA SBS-TA or Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-R10 for FL1654-R12 Certificate of Authorization #9503 Revision 10: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 11 of 31