Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE ONLY Date: I �C� t ( Receipt#: Permit #: Initials: ❑ Electrical ❑ Shed PLANNING AND DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulations Division 2300 Virginia Ave. SCANNED Fort Pierce, FL 34982 BY (772)462-1553 St. Lucie County SPECIALTY PERMIT APPLICATION ❑ Plumbing S'HVAC ❑ Fence ❑ Commercial Irrigation ❑ Demolition ❑ Gas ❑ Siding Seepage 2 for instructions and additional paperwork required for specialty pernuts 1. Location/Site Address: ✓{� F//--( J1 I( A jj� 71 �] 2. Parcel ID Number: D 00 a— �O > VV � — 3. Complete Description of Proposed Work: Cary iP.r Q_ F -+on . f 5, D- q,2 )DIi 4. 6. Owners Information 5. Contractors Information Name: (.haE(a) an M-0as Address7g4k(1 aDle ahase- City: P211 tit �{� State: 1i •77a- 10P 7 �% Zip: �j4 �y �% Phone: Value of Construction: $ '"1 (,/� • v� FL Reg/Cert #: �"ok County Cert#: 19 19 8 0 Business Name: Phone: 50 �0 �3 Fax: 9 - 4-7 Email: it i'j Q fC o? d at l OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be do'W In complia ce with all applicable laws regulating construction and zoning. z . C' �— RINT OWNER OR CONTRACTOR NAME SIGNATURE OF OWNER Ok CONTRACTOR STATE OF FLORIDA, COUNTY OF S4 i wiu ACKNOWLEDGED BEFORE ME THIS Q—DAY OF 20� BY�i �� 1 -err WHO IS PERSONALLY KNOWN TO ME ( �) OR WHO H PRODUCED AS IDENTIFICATI . Pnl aAQ,-_ l SIGN TURE OF NOTARY COMMISSION NUMBER NOTICE TO OWNER: Revised 01/03/2014 Nle®LE DEANS NOTARY Ba� C TY E OR PRINT NAME OF NOTARY + STATE OM19DA Comm# EE217824 Expifes 10/3/2016 FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. "EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink only) or typed. This permit application is to be used only for those activities that are not otherwise included under a primary building permit. This application may not be used for any activity that includes structural alteration. The information to be provided with this application includes: 1. Location/Site Address 2. Parcel ID Number 3. Description of Project or Work Activity 4. Owner Information 5. Contractor Information 6. Value of Construction Indicate the street address or general location of property where the building activity is taking place. Indicate the tax identification number of the property where the building activity is taking place. Fully describe the activity to take place. Indicate the name and address of the owner of the property on which activity is taking place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all current retail material and labor costs associated with the building/construction activity. Construction value is used to determine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. ❑ Gas Attach 2 piping schematics with tank size, location, and BTU of each appliance ❑ Shed: Attach 2 plot plans, 2 copies of DCA letter and plans, 2 anchor specifications ❑ Fence Attach 2 plot plans showing location of fence height of fence and type of fence ❑ Siding Attach 2 copies of manufactures specifications E(HVAC Attach 2 residential energy studies, 2 manual J calculations. 2 sets of duct layouts for new system or full replacement This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. NOTE. Emergency electric service change out inspections will not he performed after 3: 00 PM without special arrangements and additional fee paid. Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261. Shed/Location Permit PLEASE LOCATE SHED AND ALL BUILDINGS WITH SETBACKS TO THE PROPERTY LINES. Example of Plot Plan for shed. Please show distance from shed to the lot lines House Smith Lane FRONT PROPERTY LINE ON ROAD Shed All applications for Shed - Locational Permits are to be submitted to the St. Lucie County Building and Zoning Department, St. Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for Shed - Locational Permits must be complete and filed with the Department no later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Following the issuance of this Shed - Locational Permit, the scheduling of all required inspections may be made by calling (772) 462-1261. SLCPDSD 4/11/2011 This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. Certificate of Product Ratings AHRI Certified Reference Number: 3645739 Date: 1/27/2014 Product: Split System: Heat Pump with Remote Outdoor Unit -Air -Source Outdoor Unit Model Number. 25HBC530A**30 Indoor Unit Model Number: FX4DN(B,F)031 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: CARRIER AIR CONDITIONING Series name: Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 28800 EER Rating (Cooling) 12 50 SEER Rating (Cooling) 15 20 Heating Capacity(Btufi) @ 47 F 28200 Region IV'HSPF Rating (Heating) 8 50 Heating C4. apacity(Btuh) @ 17 F 17000 (� Ratings followed by an asterisk r) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorsethe product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibilityfor, the product(s) listed on this Certificate. AHRI expressly disdaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at wwwahridirectoryorg. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION ��' The information for the model cited on this certificate can be verified at www ahridiredoryorg, Air -Conditioning, Heating, click on `Verify Certificate" link and enter the AHRI Certified Reference Number and the date on A. on ILI and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed belowk 02013 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130353197958766846 I Florida Building Code Online Page 1 of 2 ::::.:,r :::.,:a „p:,,::nn.rn r::rn•:. , -::<,,,., ! : • , :::: ,::::,,:,:r, ;_.air.,,....L.t.......t,_.t.!_!„,•:t?::E[[,,,r,?+:[t-=:!L+:31, Ib[s,:,: i!r!kiiJJc{ia;N f ' l'. I t'I ar..ir.p..;,!..,[.;t:r:E:x:.:. :,r... tiJ?isS33s:i!r?:a?,g(?{?c!,, ta:='tts!ua^c!,risaa3,.tui.da3h,[• _ p{3c._._ <.. _.� - _ ::Pin•: r !,nl:+a!::Fa:-::n�T k"eHL_ iJE[:[; .3•;,•({(E pn[aa:::n::::.,::fn:: ?7'::•:rt ,y;,ra,[!ul,;, ,p[ 1.•[t, irjic?,Ii`^^,: <it,:1(t1j[::,�,9t!a:p um:r. p[ nc:f.^.[:[:[�IA�1:[:...,�r., n , _ 1 . {i�i�� �' .1�15 ! 1 [:.IEI'i'.ir •:::; • !!3:3.fdu:r.t.,:nvnn:;..I.iy_.t•u�3,irn,in�pn:•rfa,^',%:r•;; E!!E ii $•p,; h.::iji .,t:; {::�.. •. - 1. ?[n!lll'i ;;?: :,?a•at•::r3i !: r. •P ,:ai?aa[r.?J •i4:i x t!y, : L•uii ,[i 3..:•.d?.. .a 'i, i!iLt,{ !j? :4''-S4 ... $!27fi[na}inn:il:a y J , ,[ ,,,...,l.r.f...,,[ f ..,.[!.,,u [ ",,, '[i33Fg{d:P?:?:::r."i!a3::?IiaP.?EE!_4i�IJrj,iiit:a:i;t'^rl3?3ii(•:;?:?3:.; rr._,C..Irn.,?rl.,,;in:•?Jtf�,Pbfn;�,,7,1;r lr • tg', r t { i i • 91:.:^ i i(((11 n t' I'1I iill [ Ei Rr IL, dFt a ri.t{r, {u 4 r) .tiu.[�1� I?{r�ifE . (1 .' !• : • j:t 1: att#I!jr,� 1, :' i �!.w :, E(i, 77 ut.j{?;; !iJUL7 v% I.1•; ' t 4 j Ir,,..�. 3{I r•:L!. L'f G i n l yt !•'a'jE�jJ;i i�:�3{•'r'I iii'�• rr 31• r. ,., <p1i :[ %W 8!i' �{.•. •'. A%n— ,,1•:.k ,ttva.:: R- F , 31:;tn. J!.:..ti?,:,. i j � :E+ . h f r. i^ F (•i •ot.:liiS[I�au!it+�luia���t):�a R"�{I •t it d3�i r• , � f • � i��pp in:fi+ I 1 :nbY.,tu JIEif.:3•••... •••, {It^31!I t n rn :?.. f�'i •�!ittl:[•U ? 3" 1' 1{"! 1{� � •• ,• t:•:!:{?4:!3?i!UF?ii[.J?Si;l:!:F.irS. iii:ii.n, •:::•[:a:^^°••,9 ^ ::'t:'"mEii'E �if•r••,•an:,:at:, ..., .l..t.i•t.rl.[t, ii.• �1 . :[nr•+ [:{n._{�{[pr::[•, •qrg arr.•,+arm:n •sr. r. •s=r: [ r'..n r. ..... ... .....1 L.,.,...S.:p,nt,.r itnia;,![jr j Jrr ! [ , [[ r i n r m^ar•I•?nr...[.,.. .^ �r �slil.•u. [ :.';r.: jr t� qj fi m }..� :rF ' i! ll? ut r L , Ir [r r.E;i !Sa •...........,.. t 3 ...: 1.,., [.', i 1 i r .. _Itr_,1iL {emp nalt•+`i$��1�• lr'±t'9 ( i'.h q'; ' .,.:., .. ��.{L.-t..{1t d.E._!t. �ahtJ [ li a:r;.:,r,f.,t,,,.:E,:.,.ra...:......_.............[.-:...J.,.:.,[fE.'vn[:I el,n� .... E_.tlF�. • „�:: piai!i,friii$t<i r.[ tF' rn:n..NG..:.,iJ.t. ,. at•t.:i "i�Il.;�.� L': A%i%ritr??t•1I gC15 Home 'Log In 'User Registration Hot Topics Submit Surcharge Stats & Facts Publicauon5 FBC Staff BC[S Site Map i Links 'Search Busines '''`l ''' Product Approval �5a � Professi ` flak` USER: Public User�P Regulation "` ProdySLAyoroval Menu > Product ur duuliration Search > Aooi!cation List > Application Detail Ribu J YC{5l41rd�!! x3!! 5?�11i,UN iji's!<''Ij'aS,jiF51)�Ii+l{i �'N+?I FL # FL14239-RI Application Type Revision Code Version 2010 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report; Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code BMP International Inc. 4710 28th Street N St. Petersburg, FL 33714 (727)458-0544 - benmengB@yahoo.com Xlanbin Meng benmeng8@yahoo-corn Structural Components Anchors Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Frank L. Bernardo, P.E. PE-0046549 National Accreditation & Management Institute, 12/31/2013 Ryan J. King, P.E. YI Validation Checklist -Hardcopy Received FL14739 RS COI COI.odf Standard ASTM D1761-06 ASTM D1761-88 Florida Licensed Professional Engineer or Architect FL14239 Ri Eauiv Eauiv.Ddf Year 2006 2000 htip://www. floridabuilding.org/pr/pr_app_dtl.aspx?parani=wGEVXQwtDquDEJErtOS Cei... 2/13/2013 e � f Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 09/29/2011 Date Validated 12/13/2011 Date Pending FBC Approval 12/18/2011 Date Approved 01/31/2012 Summary of Products FL # Model, Number or Name Description 14239.1 Slotted Steel Tie -Down Clips, 1" Steel Tie -Down Clip System (For Use with Mechanical I and 2" Models Units at Roof or Grade) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL14239 Rl II Dwa.odf Approved for use outside HVHZ: Yes. Verified By: Frank L. Bennardo, P.E. 0046549 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: This design provides allowable capacities for the fL14239 RI AE L-valmdf I system. The required site -specific design pressure Created- by Independent Third Party: Yes (demand) shall be calculated by; others for use with this design. Aaek Next Contact Us :; 1940 North Monroe ctrept Tallahassee FL 3 3Q9 Phone: 850-487.182a The State of Florida Is an AA/EEO employer. Convrloht 2007J01_(ZState of Florida.:: Privacy Statement :: Accessibility Statement :: Refund.Slatainent Under Florida law, email addresses are public records. IF you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. •Pursuant to Section 455.275(1), Florida; Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here Product Approval Accepts: littp://www.floridabuilding.org/prlpl _app_dtl.aspx?param=wGEVXQwtDquDEJErtOS Cei... 2/ 13 /2013 BMP INTERNATIONAL, INC. MECHANICAL UNIT STEEL TIE -DOWN CLIP CAPACITIES: AT GRADE & ROOF -TOP MOUNTED APPLICATIONS I E'OL B MIN. WEIGHT, FAEG{AN LCAL UNIT PER SEPARATE TYP. CERTTNCATION, ' SEE DESIGN 7CUITER OF j! SCHEDULE FOR r GR,lVII'. MA,`CLMUM SURFACE AREA AND DESIGN PRESSURE, TYP. . STEEL TEE -DOWN CLIPS. • /' / SEE �1,2\, L 11 DI ONI TO TIED WN ADDITION SCHEDULE FOR CLIP INFORMATION, TYP. 3-.14AXI I CENTER OF GRA.V1TYt ASSUMED TO ACT AT THEI i,-` GEODIETRIC CENTER OF THE' _ MECL UNIHANT MUSUICAL TNBEIti.l i MECHANICA SQUARE OR RECTANGULAR, y u NO IRRECULAR SHAPES. z �O �w 2F L; m _ , I 3• MAXI , ...,... !. TYP, �� • HOST STRUCTURE DESIGN 6Y OTHERS. - _ . rB•-7 .. SEE TIE -DOWN SCHEDULES FOR ALLOSVAOLESIIBSTRATES. ROTE,: WOOD MEMBERS MAY NOT BE USED FOR - ROOF -TOP APPLICATIONS PER FBC 1522. . DOUBLE CLIP OPTION: (2) TOTAL CUPS MAY BE USED AT EACH CORNER (ONE EACH 014 OPPOSING CORNER FACES, 3- FROM CORNER APEX, TOTAL OF (S3 of PS P''R UNIT FOR THIS OpTIDY), EACH CUP STALL HOT EXCEED 3- MAX OFFSET FROM END OF MECHANICAL UNIT AS MAX 'TYP. '`AAQSSrOO��� -TYP..:: ,AAB iUTILEzE (1) CLIP- AT EACH CORNER '-IAs SHOWN WITN 3' MAX OFFSET !FROM END OF MECHANICAL UNIT. , DETAILED EI HERN. DO NOT SPACE CONCRETE ANCHORS CLOSER 1 THANTHE ALLOWED SPACING LISTED IN THE TIE -DOWN MECHANICAL UNIT ANCHORSCHEDULES.SEESHEEETS2?,3FORM0RE --' i TIE -DOWN ISOMETRIC INF00.I4ATIOM, t_ ..._ 1 ISOMETRIC 'FIR CIARRY, TH15 iSOHETRIC @YLY SHoW51" CUPS. THE I`_DI— 4ETRIC L YOU' IS 7YPiG\L FOR BOTH 1' AIYD 2' CUP AFPltCATIONS. 2' CUPS I i,RE NO- CERT[F:ED FA't AfICHORAGE YO CONCRETE. -DOWN CLIP DIRECTIVE EXAMPLE IE FOCLDS7RIG EXAMPLE ILUISTRATES THE PROCEDURE 1,5ED 70 DETERMINE THE MAXV4UN ALLOWABLE ININD PRESSURE FOR ANY GIVEN MECHANICAL UNITTHAI NENSIDN RESTRICTIONS LISTED HEREIN. SEE SHEETS 203 FO7TIE-DOWN SCHEDULES.) MECHANICAL UNIT CRITERIA: CONSIDER THE Imi-TION OF (i) MECHANICAL UGIT :'JOH THE FOLLOWING CRITERIA- 36' TAU- x 36' DEEP x 24' WIDE, 150 LB WTIBNT AS VERMED BY OTHE4S, INSTALLED TO 3192 KSI MITI. -ZIXP..ETE AT GRADE AS VERIFIED BY OTHERS. TO THE Co.4CWSfOY:HitT:1LS4ALLD'Y..�BLEIA.TE9ALDESIGN-'nSSU.Y•- �1 OFSF� (Copp^RE TITS VALUE TD THE SEP ARATE SITE SFEC7FIC REQUIRED DESIGN' lYIYD,I(E_SSURE PFOV!Oc0 BY A L'CE.'50 Eh. 9I:.E_n OR REGiSTFRED ARCHOiQ; NO, RlUb'DED LH ,TITS CER71FAr4TIWj �_ ABRICA T ED IN 1. THIS PRODUCT HAS BEEN DESIGNED AND SHALL BE FABRICATED ACCORDANCE W[TH THE REQUIREMENTS OFTHE 2010 FLORIDA BUILDING •I, 1 "r CODE, FOR USE WITHIN AND OUTSIDE THE HIGH IITLGCrTY HURRICAI,E ZCNE. HAS BEEN USED IN THE ; 2, NO 33-1/3-6 INCREASE IN ALLOWABLE STRESS DEST GN OF THIS SYSTEM. 3. DESIGN 15 BASED ON CLIENT PROVIDED PRODUCT AND DIE SHEETS FROM TESY x uT w� REPORTS GTFL 01970301A, ;t-.EL 01970387E BY TESTING EVALUATION Q 2,z ; a LABORATORIES, INC.. NO SUBSTITU'TONS wiTNOUT WRITTEN APPROVAL BY IS ENGINEER SHALL BE PERMITTED. c i u ZR W l o'P S z T 4. ALLOWABLE DESIGN PRESSURES TO QUALIFY CAPACITY OF CLIPS AS LISTED ' HEREIN ARE DETERMINED THROUGH TESTING REPORT DATA AND RATIONALLY CHECKED FOR CONSISTENCY WITH EACH TEST PERFORMED. 5. REQUIRED LATERAL AND/OR UPLIFT DESIGN PRESSURES CALCULATED FOR USE KITH THIS SYSTEM SHALL 6E DETERMl^lED BY OTHERS ON A SD'E-SPEmCCO- ASIS IN ACCORDANCE WITH THE GOVERNING CODE. 6. MAXIMUM if MIPU14UM DIMENSIONS AND MINIFIUN WEIGHT OF MECHANICAL UNIT SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY ' �.. ..._ . OFTHE CONTRAMR: ....__..._-.__._._... _ .. _ _ .. 7, FASTENERS TO B= '12 X ,' OR GREATER SAE GRACE S UNLESS NOTED OTHERWISE. TAPCOMS REFERRED TO HEREIN SHALL BE ITW BUILDEX BRAND, ay .'� CARBON STEEL ONLY, INSTALLED TO 3192 KSI MIN CONCRETE. SEE ANCHOR SCHEDULE FOR ANCHOR REQUIREMENTS. ALL FASTENERS SMALL HAVE .+ APPROPRIATE CCRROSIOM PROTECTION TO PREVENT ELECTROLYSIS. 3. ALL STEEL CUPS SHALL BE AS.M A233 STEEL (GRADE D) WITH Fy - 33 KSI 02 z a BETTER. ALL STEEL MEMBERS SHALL BE PROTECTED AGAINST CORROSION WITH - r AN ApPROVED COAT OF PAINT, ENAMEL OR OTHER APPROVED PROTECTION IN P WE I N ACCORDANCE WITH THE 2010 FBC SECTIONS 22U3.2 AND 2220. G90•PLATED ti COATING REQUIRED FOR ALL COASTAL INSTALLATIONS. 9. ALL CONCRETE SPECIFIED HEREIN IS NOT PART OF THIS CERTIFICATION. AS A MINYII.RIM, ALL CONCRETE SMALL BE STRUCTURAL CONCRETE 4' MIN. THICK AND SHALL HAVE MINIMUM COMPRESSIVE STRENGTH OF 3192 FSI, UNLESS NOTE-0 LLIc OTHERWISE. 10, ALL WOOD MEMBERS SHALL BE PRESSURETREATED SOUTHERN YELLOW PINE GRADE :2 WITH SPECIFIC GRAVITY G o 0.55 OR GREATER, DIRECT FOR ROOF CONNECTION TO WOOD NTEi49ERGfSLEEPERS IS NOT PERMITTED -TOP E APPLICATIONS PER FBC SECODN 1522. 11. THE CONTRACTOR 15 RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSRH D'IR MATERIALS TO PREVENT ELECTROLYSIS; I.E. ALUMINUM PER F.B.C. m 2a63.E.4. + 12. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED 19 INSTALLED BY OTHERS. 13. THE ADEQUACY OF ANY EXISTING STRUCTURE TO W ITHSTAHD SUPERIMpOSED - LOADS SHALL RE'VERIF1ED BY THE O.NSITE DESIGN PROFESSIONAL AND IS NOT c INCLUDED IN THIS CERTIFICATEoN.EXCEFTAS EXPRESSLY PROVIDED HEREII, OR AFFIRMATIONSARE INTENDED. a IT. NO ADDITiO'7AL C[3iiIFICATICNS PROVIDE !Qc ±4. THESYSITEM DETAILED HEREIN IS GENERIC AND DOES NOT FROM y3+% INFOPJ•tATION FOR A SPECIFIC SITE. FOR SITE CONDITIONS DIFFERENT THE CE)NDITIONS DETAILED HEREIN, A LICENSED ENGINEER OR REGISTERED ! g ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN 1� I 'AN `s�<= COPOUNCTION WITH THIS DOCUMENT. SHALL BE THE FULL 1 -9H = EHTNESS OF EXISTING HOST SUBSTRATE 15. P. ,I SHALL j I �1_r, RESFOP �[BiLITY OF THE INSTALLING CONTRACTOR. CONTRACTOR REST »I T $'.�� ENSURE TIIAT ANY REMOVED, OR ALTERED WATERPRCOFING MEMBRANE IS ! TORED AFTER FABRICATION AND INSTALLATION OFSTRUCRE PROPOSED RSR #92 HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY .. WAIERPROOFIING OR LEAKAGE ISSUES WKTCH MAY OCCUR AS _. rca,rzRxl:l sFau£'+u?t WATERTIGHTNESS SHALL BE THE FULL RESFONsi5may OF THE INSTALLING CONTRACTOR. l i-BM P-0001 Cd 1" STEEL CLIP_ TIE -DOWN_ SCHEDULE: AT GRADE INSTALLATIONS: _ - �T ' MAX&,tUM1I AL_LOWASLEl1LTERAC YJIND PRESSUP.E (ANCHOR TO HOST STRUCTURE) E ` _ (1) CUP A7 EACH CORtJER (FOT.iL DF 4 CLIPa' PER UNIT) i (2) CLIPS AT EACH CORNER (TOTAL OF B CLIPS PER UNM R'+ti(IR1Ua15URFAC-- AREA OF UNITS UNIT 1 HEIGHT 'SIT' TM'� SHEET METAL SCREE SHETNETAL SCREW WOOD SCRE'+°I TO TAPCONTO NIETkL SCREWTO SSCREV.710 SHEET METAL I iMOOO SCRa'17e STEEL SGRE:Y7o YiDOD LARGESTFACE i I TAPCD4 TO CONCRETE TOALUVINUM TO STEEL WOOD I CONCRETE I ALU6OMJM j I fM PSF I 91 PSF 91 PSF i 91 PSF __. 100 PSF 1OO PSF _ J.. ...II I_ __ tU0 PSF 1 100 PSF 1 FT' _— fi1 PSF I - --6'1 PSF 61 PSF PSF _ _ 100 PSF i- f00 PSF i 100 PSF .^ 6F7' ^� ° BS PSF _ A PSF 40 PSF 40 PSF 40 P9r �' 77 PSF 77 PSF 77 PSF ( TT PSF 9 FP 48 I,?4X �'— 24' MIN )J 30 PSF 30 PSF SB PSF 69 PSF 56 PSF 58 FSF 12 FT' 30 PSF 30 PSF_ , __. .__.. I Ia PSF i 43PSF 1 43 FSF --_ 60'MAX 46"MR4 .. �.__'l1 'wi r� "/�r1' `/��//Y // 30 FT' .,.,�..,- 36FT+ 1. TIE -DOWN CLIPS SFi,'L' BE FASTENED TO MECHANICAL HOUSDJG UNIT 1YR<', (3)-*12 SAE GRADES SHEETMETi%LSCRtA'fS. ((5)-SKEET METAL SCREWS REQUIRED FOR LONG CUPS, 51EE LIETATL 1J4.) 2. FIECM aCAL 1ICUS114G UNIT S141' LL CONFORM TO THE FOU.CYJING; 2.1. AL'Jt-UNUM NOOSING UI(ITS SHWA BE 6063-TG PHIL ALUMINUM SHEET WfFH 7ty-3D KSI, 0. 25° M[M 7HICKNESS. 2.2E STEEL I'lOU5L4G ULJITS SHALL BE 3315I FI1N. STEER, GRADE 33, 22GA N W. (t�.0290'). 3. MAAIMUMALLOWAELE WIND PRESSURES FOR EACH INDIVIDUAL SUSSTFATE MAYBE E(?JNALETIT DUE TO THE LIMITING CAPACITY OFTHE 1° CLIP. 4. A HAYJMUM AL_' iLE VALUE OF 100 PSF HAS BEEP UTILIZED; FOR HIGHER DEMAND C.',PACITIE'S CORTAU. THIS ENGINEER FOR SITE-SPECLFLC ENGINEERING. ANCHOR SCHEDULE• SUBSTRATE _(____ANCHOR CONCRETE: (1)-Y"p CARBON STEEL ITW SUILOEX kPCON, I;'+ FULL EMBED TO CONCRETE, 2)4 MIN. ANC{H_._ (4• THICL FIIIJ, 3792KSi MIN.) ( EOGEDLSTANCE,3'MN.,SPACII2GTOILWAD7ACET ALUMINUM: �- k(1)-= 14 S4C GRADE S SHEET METAL SCREW TO ALUMINUM, PROVIDES) PLCCHES FUN. (0.325 N!R. TMCC, 6U61-iE MIN. FLL'Y,IN'JLA}I PAST THREAD PANE FOR SHEET t4L7AL SCREW. - ' (1)-914 SAE GRADE 5 SHEET METAL SCREW TO STEEL, PROVIDE 15) PINCHES MIN. PAST STEEL: �(O.17S' MIN. THICK, 33 KSI MIN. STEEL) THREAD PWIF FOR. SHEET 14ETAL SIXftY. - '-'—_------"�— (1)-Y14 SAE GRADE WOOD SCREV+TO'1fC00 FQ12ER, PROVIDE i'<:" MIN. THREAD DISTANCE, i° MIN: END L+iSFANCE. ((SOUTHERN YELLOW PINE, G�0.55 OR BETTER) PEF7� ftAT[ON. 1" Fi1N. EDGE ANCHOR SCHEOUI.E FIOTES: tI. EMBED.l�ENTAt]DEDGEDL%ARCEEXCWDBFINGHES,IFAPPLICAt-'- 2, ENSURE MINIMUM EDGE O{STANCEAS NOTED RJ AHCHOR SCHEDULE TtA9LE LEGEND! —�� -DENOTES E,AMFLE VALUE FOR USE WITH COVER PAGE DIRECTIVE -DENOTES VALUES NOT APPROVED FUR U56 2" STEEL CLIP TIE -DOWN SCHEDULE: AT GRADE INSTALLATIONS: MRXIN.U74 ALUDVJAB' LATERAL WINO PR(A ESSURE NOiK)R TO NOS: STRUCTHRE) AtM SGLVACE Uyn utiR (1) C ATAT EAG4 CGRHER (TOTAL OF4 CUPS PERUNIT) ; (2) CUPS AT EACH COR.;VE4 fTOTAL.OF 9 CLIPS -PEP, UNIT`. i AREA OF U:IIT5 NEIGNT Y.RD� rl c1{[{T METAL SCRE:V WOOD SCREW TO SCRE'V TO 6- TO SHEETMETAL i S}IETMETAL WOOD Sf12-VI LARGEST FACE I SHELTMETAL SCRs•"fl E WOOD ' SCREW TU ,EEL WCCD i TO ALLA V4UM TO ST-EL AUP71NL1M ' 4B " MPL: 1 24 " MIN I I � EEt ^ NAX 46 " MUJ 27 PSF � 27 PSF 27 PSF ( I _ 57 PSF I 53 PSF I bJ L'=1- t ' 1. Ti&00'1/N G.IFS SNaLL BE FASTENED TO MEQi1WCAL HOU'a1HG UNTI' WITLL (3)-F32 SAE GPM1DE 5 SIi-ET MEAL SCREWS. 2. MECHANICAL HOUSING ULJITSHALL CCSIFOR,M TO THE FDLLOVJIHG: 2,1E aWMCN11Tt HOUSING Ut1I7$ SHAs L DE EOE3-TK MiN. ALI/HINUM SHeET Ceti H RY=� K$I, 0.12� 41A'.' iICKNE53. . 2.2E SYER HOUS[tiG UNIT$ SHALL BE 33K51 M[M. STEEL, GRADE 33, 22GA MRJ. ([=C.0299'). FO.R ' 1. A MARL :UPI ALLOWABLE VALUE OF 100 PSF HA5 BEFF1 UTiLtZU; FOR HIl3;IR pGaJ`NO CAPACITIES COt�ACT THIS ENGBdcER SLTE-SPEC FIC ENGINEERIJG. ANCHOR SCHEDULE: _ _�-• �-y ANCHOR l ANCHOR SCHEDULE 0,ES: SU657RATC I SHEECMETA: SCREW TD ALUMINl1%PROVIDE(5)PFYCFT3 MIN. 1. EMBEDMEMT .'LCJO EDGE DLTA:`JCE ASNO E F]NANCH,LF 42PLIUB_. PASlT§, EISL'R'c HINIFIU4 EDC2 DISTANCEAS NOTED ]H RNCFX)RSCHEDUL'u ALUMiNL44:_----�—il2)-=14 SAE GRADES )(0.125°MIN. THICK, 6061-T6f49(.ALUM;."D1M); THREAD PIA PIE FOR SHEET HUAL•SCREW. - STEEL.___-----! (2)-a14 SAE GRADE S SHCE.- METAL SCREW TO PROVIDE (5) FINCHES MRJ. FAST j (0.125' HRJ. i11LCK, 33 KSI Mlii STET'.] THRE-0 PLANE FOR SHEET METAL SCREW. _ _ F MUS THICY.FIESS: L21'- 1+: SAE GRADE 5 4YD0] SCREL'1 TU WOCD W:,d BEN, FRO'.,Ia Sit' HIS:. THREAD SEALED 1Y00C, 1-Sf2' a^ 17'AdLE LEGEItU: -- q %..�4( -DENOTES VALUE F:1T APPROVED FOR USE �(S� ERN YELL O:. PINE, G=0.55 OR 6M11) PEN.L74ATION, 1° }ILN, EDG= DISTANCE, 1- MIN. END DISTAtF_E. __ ..... .. 7 -I : i W = (X ^ D 'ag" 6 £Cotsw°g "a931_ z � Iti Zan m �o a � }z -3 Lu -•as < d m s u4PlniGf1 f11NHL=:•'SfI6Tz_ 11=8MP-0001 SCALE( NX.. Oi RAGE OFSCR]DTION• , 1" STEEL CLIP TIE -DOWN SCHEDULE: ROOF -TOP MOUNTED INSTALLATIONS: ( IB Ih1UJAALLOWABLE IAr WIND PRESSURE (ANCHORTO H057 STRUCTURE) y � I NAXOdUM SURFACE j _� itICUPATEAGH CrRNER QOTN. OF4 CLIPS PFR UNITI 17{CLIPS AT EACH..^.ORNERsFOTAL GFB CLIPS PER I'tnY)_ I Li'_" ROnf i"OPiA1TA4ATl0!:SS,rALLLT}:t'Pp.¢Fr AREAOFUIJIT3 UNIT UNIT tNIDTNr SHEET META! Ioa+:rroA a+nwirr: cuesoN lsmlann HEIGHT SHEET 64ETAL SCREW SHEET f4ETAL SCREW 1 TAPCCN TO SNEET h1ET.4L I LARGEST FACE I I TAPCOMI TO CONCRETE I SCREW TO x0 SW Awi PEO.'nfl� marmoF ' 1 I TOALLNINW>f TO STe'eL CONCRETE I SCREW TO STEEL' xwu:IallraAwutLw,TsOENxrurn ar E ALUh1W, 1 ypeg zY5E.2 a1;JrLN(:.Ye+91n'o,s.wa: n:E 4 FT'1 82 PSF PSF { 62 PSF 100 PSF I 100 PSF I i00 PSF z'=u'P^-E, F•Y%�Exca'nreNAralis r7(TnJ! EE1v+�F! MF1M:X LTlAascP g Fla I 41 PSF 47 P$F 4T PSF 77 PSF Ti PSF 7T PSF I[Fus7�rTSU.=!'c.2r.'fHG+!a sr.:rJmlvu OA r i 9 FP ( 48' MAX( 2C' 6L'N 21 PSF ! 27 PSF 27 PSF 5-, PSF 51 PEP 51 PSF �° "��flrA .v T9PA!iUMJt JSti CTiTF4tYiU2t I �•,i�%/� �%�,'4%.%jam%„ j 38 FSF 12 FT' i i ,/. �fj�"� fi�l IBA I_I ir•%�!:,i�Y/ fii'/ji 29 PSF 1 38 PSF 38 PSF_�IfOOE TD FEFNrT?�PAIFS AECFNc i:'A'G^¢ r � xaavr3rzcEc=�flcaas'crrsric ar.•wan 1 -_ 29 PSF 20 P5.' cA.uFEoc: w:.r4rn rcnN LvsUev. r�ru� i HAvtSc•�Y,fE OJCYi,MGRATfO!r .a:�Ya+. j 20 FT' 33 PEP 33 PSF I 26 PSF 1 26 PSF lxrEmrn A.vu is C•NSrnF n+E scot r.Pm!s 26 FT. 40 M,N z;= r / /' % "Old `sO FP lil///•'//'. l! %N� '/ T% i�'.,rl"fL� 1. Tic -DOWN CLIPS STALL BE FASTEHEDTO fIECHAn:CAL HOt1S1'IG UNTT LY7TH (3)-312 SAE GRADE 5 SH=H'T METAL SCR?A'S. ((5)-SHEET METAL SCREWS REQUIRED FOR LONG CLIPS, SEE DETAIL 114.) SLCGNTO-IEM_OVnNG: ADDITIONAL ALLOWABLE UPLIFT: 90 LBS/CLIP 2. MECHANICALHOUS;iiGUNLTHALZRM 2.1. ALUMINUM HOUSING UNITS S!IAI18-c 6053-76 MIN. ALUMINUM SHEET WITH FIy=30 XSt, 0.125' MIN. THi-_WIESS, (t-0.0299'). (DC3IGN TABLE ACCOMMCDATES MAX 9DLB/CLIP AS AGDIPONAL UPLIFT IN 22. STEELHOUING uN17S SHALT. BE 33XSI MIN. STEEL, GRADE 33. 22GA PUN. ALLOWABLE WIND PRESSURES FOR EACH INDIVIDUAL SUBSTRATE MAY BE EQUIVALENT DUE TO IiF LIMITING CAPACITY OF THE 1' CLIP. !'CMBUTATIDN YlITH UPLIFT PAUSED 8Y OVERTURTRNG F:iGM LATERAL M7L\IMUM A MAX[MUFI ALFGlYABLE VALUE OF U)O PSF HAS BEUi GTIL2E6; FOR HIGHER DEMAND CAPACITIES CONTACTTHIS ERGIH"cER:OR SITE -SPECIFIC FORCES. SEE ASCE 7-10 SECTION 295 FOP. MORE RNFCRRATION.) F_'GT::EERl1G. AtLOWAeLE UPLIFT PER UNIT IS BASED ON r . ANCHOR SCHEDULE' THE NUMSER OF CUPS UTILIZED X 90L8VCU . ........._.... ... _.. .. . , - __ _ __._. ... .._... .... ANCHOR ..... j. .. _.___: .I _ ... SU85TRATE � EkNllA.. _UCUP . - .. ..-.. ...... E' 4 CUPS X °0 LB! 3E0L 8 CONCRETE: ': (lY5'D CA.58R0!J STEEL TRY 13UILDEX TAPCOH. l;ti' FULL EMBED TO CONCRETE. 2i;' PUN. ! EDGE DISTANCE, 3' MIN. SPACI\G TU APP( ADJACENT ANCHORR. t (REQQJIfL"J UPLll-DEPLTND S.YAIl EE OcTR :1NA ! (A' 7HICt Mi,., 3I92XSi T•1UL) j ALUKIN:X4: I(r)• 14SAECAADC55HEET M=EA'vSt-TiEY TO ALUM^:V4, PROVICE (SjPWC1♦rS MIN, OVA SI7E SPEC07CaASIS BY LTCEMSED ENGF.VEER OR iEvI.57�-`�1�^GLF:EL:,-A'O'Fi+.�1UDEO LN7"IS - IF 0.125° MIN. TryICK, 606i-T6 ISIN. ALUP!UNN) PASTTU7EFD PLANE FOR SHEEC;4ETAL SCRC:7. -. IAT1FiCA77CNI STEEL: (!),WU SAEGRADES SHEET METAL SCAM9V TO STEEL, PROViOE (5) PINCHES MIN. PAST TABLE LEGEND: Y( (0.125- MIN. THICK, 33 KS M(K. ST:Ej THREAD PIA:`!E FOR SrIEEi METAL SCRE4'/, j/✓� -DENOTES VALUE3 NOT APPROVED FOR USE 1. EMBEDMENT ANC EDGE 015KAUCE EXCLUDES FINISHES,IF APPLICABLE. 2. ENSURE DIIRI.MUM EDGE G13TAfiCE AS NOTED IN ANCHOR SCHEDll(B. _ � 2rI STEEL CLIP TIE -DOWN SCHEDULE: ROOF -TOP MOUNTED INSTALLATIONS: 1. TI&DOWN CLIPS S+ALL RE FASTc'1^.ED TO I4{MANIC 1 HCW'!NG UNIT ;V.TH [3j�11/. Snt wu'ue � xcr., , r,n�.�.:....._. 2, MECHANICALHOUSIt(G UNIT SHALLCANFORMTO THE FOLLOWING: I.1. ALUMINUM HOUSING UNITS SMALL BE 6363-Tu MM. ALUMINUM SHEET WITH FTy=3O KS!, 0.12V MIN. TH(CANESS� 2.2. STEEL HOUSING UNITS SMALL BE 33k51 RIM. STEEL, GRADE 33, 22GA P1U'1. (T=0.0299') 3. A MAXIMUM ALLOWABLE VALUE CF 100 PSF HAS BEEH UTILIZED: FOR HIGHER DEM VID CAPACITIES CONTACTTH!S ENGINEER, SITE -SPECIFIC ENCINEEIMUG. -�--- ALUM[^NUM: I (I)-S_4 SAE GRADE 5 SHEET METAL SCREYI TO ALUMINUM, PPOVIDE (5) PINCHES MIN- WOS (0.125-MTN.T,GCd1-TL MIN.4111MUIUM.1 PAST THREAD PLANE FOR SHEETMEiAL SCREEN. 5TE-+L• I (2)-,-14 SAE GRADE S SHEET METAL SGEYJ TO STC�, PROVIDE (5) PINCHES AIM PAS (al2S°F1W.THICef, i1;;SIMINV 31EEL) ITINTER➢PLANE FCR SHET i+ETAMSCRE:J. 1. EMSSEDFIENT AND EOu D[STAIXE EXCLUDES 'FIBSHES, IF.AP?UCABLE. 2. EHSLJRE 11211HUM EDGE OlS CS AS IJO.ED IH AV0tCR SCMEOL'I - j ttOlE Aair�I-�!�[tAII:Y�S 5:41L CLNbAi! fG lrDAlJA EiaeOML LOUFSL=RPV I509 TN+? li7l POR hYN7 kNlCNiEQUl�i MATx0.^P 1NAFC'8JACE flAFiOFFtOn?TERNrAVIIS , _:rTPMJ EEL, UP -rC Tv M'TIf, W!ii AM .'¢,U -YEW ^.,PFC.¢tAUvrU(!+nAr!1"!UJJfr 11 E:.NJ.'FIRFf�(IIXACfJRJAYW 9l.-R! StinUN liP. FYDICR a5:20FTNEmIMfNn [pTti�TJ Pi¢MTP.rPA!RL PEEVLSVP[P, M9iJY !44'MtiR:l.Y2 C°"T1:£!C�'vG SYSItx. /AY CliR9 a¢'_'JFP39T�um mm ars UESTrvrsRru tt+F'csr'Aartrco_wrutiurcY�anv.Yz I hTEt1cMANDb CUTSrUE THE SYDCEG'TRS ADDITIONAL ALLOWABLE UPLIFT: 90 LBS/CLIP (DESIGN TABLE ACCOMMODATES MAX 98LBICL'P AS ADDIiIOWL UPU IN COMBINATION WITH UPLIFT CAUSED BY OVERTURNING FROM LATERAL FORCES. 5FE ASCE 7-10 SECTION 29.5 FOR I•tORE.:-+7FCNMT.ON.) ALLOWABLE UPLIFT PER UNIT IS EASED ON THE NIptBER OF CUPS UTIUZEO X 90LB%CLIP F,XAMILF, 4 CLIPS X 90 LWO!P =35OLS (REQUIRED UPLl7DgPWiD SHALL BE DET:RMINEU i O;Y A SITE SPECIrJC BASIS SY IICNSED ENGINEER OR R.EGh;*REO ARCHr! CT; 1TOT INCLUDED IN il.- C&ITIFFCATION) -UEUCTES VALUE NOT APPROVED FOR USE Q�c a O C p(vx v Q a J H s U zca 11-BMP-0001 S[ALL N.TS. 01 UGE �F.SCATPT;QN; J TYP. 0.068- THia—.. ASTM A263 STEEL4 nP. "W i %� IYt1i I o 4 li (3)-g11 SAE GRADE 5 F CR ANY CLIP LONGER THAN 10• SAE GRADE UTLIZE (5)-712 SHEET METAL SCREWS (PROVIDE SCRENS A7 1IIi VOLT BY OTHERS. ALUMINUM MECHANICAL V 2-iiiN. SHErtT METAL THE TOP OF THE CLIP) TYP. I HOUS1tKa UNITS SHAD. 3E 6063-TE MIN. --- ALUMINUM EET'M SHIH F[y=30 KSi, 0.125" MIN. A i THICKNESSS EL HOUSeiiG UNITS SHALL BE -' 1-5, IE ti 33KST MIN. STEEL, GRACE 33, 22CA MIN. (Ie0.0299'). � w( '9 0.068' THICK A_cM- y A2U3 STEa CLIP, r(P. BASE OF UNIT SHAL'_.- H' BE (LUSH \KITH 5A5E OF CLIP, NO SPACE ' "A PERMITTED, nP. SHEET METAL SCREWS -l; �i (i Si 0 HCLE, wwl (OTHER AT TOP OF SLOT, TYP_ Il, ANCHOR FROM 1- I, CLIP ANCHOR DIMENSIONS 0.75" III i �. �.--- SCHEDULE, TYP. SIMILAR) 1 I" CLIP ISOMETRIC DETAIL 4 N.T.S. ISONETRiC o.125J; j ' s Q.IL'°THUG: ASTM A283ji •-+j' STEEL, TYP. III L (3)-#12 SAE GRADE 5 SHEET METAL SCREVIS AT TOP OF SLOT,nP. 3q O HOLES, NOT TO I I BE USED FOR ANCHORS, TYP. 0 IT 6.375 FACTORY -MILLED "'O HOLES" J1Z ' DSO,., -;I UTILIZE ANCHORS FROM 2" CLIP ANCHOR SCHEOULE,TYP. 05 ?_22" CLIP ISOMETRIC DETAIL ----�N 4 N.T.S. ISOMETRIC (3)-A 12 SAE GRADE 5 SHEET METAL SCRE:VS THROUGH CLIP- TO MECHANICAL HOUSING UNIT BY OTHERS. PROVIDE (5) PINCHES MIN. PAST THREAD PLANE FOR EACH EMS, TYP. —ANCHOR FER ANCHOR SCHEDULE x Su"STRATE PER ANCHOR _..__.____..__r___.......__ ... SCHEDULE (VARIES) 1".TIE-DOWN. CLIP s ANCHOR DETAIL 4 3' = 1'-0' DETAIL CLIP' D( SIGNED FOR FULL -I CONTACT WITFI THE BASE OF EACH MECHANICAL UNIT, , _' MEr_'blQHCAL UNIT BY OTHERS. ALUMINUM HOUSING UNITS SHALL BE 60E3-T5 MIN. ALUMINUM SHEET WITH F'Y-30 KSI, 0.125.141N. THICKNESS, SEEL HOUSING UNITS SHALL BE 33K51 MIN. STEEL, GRADE 33, 22GA MIN. 0.113"THICK ASTM,- AZU3 STEEL CLIP, TYP.' BASE OF UNIT SHALL-, BE FLUSH V4ITH BASE OF CLIP, NO SPACE PERMITTED, TYP. (3)-112 SAE GRADE 5 SHEET METAI. SCREWS THROUGH CLIP TO -MECHANICAL HOUSING UNIT BY OTHERS. PROVIDE (5) PUNCHES MIN. PAST THREAD PLANE FOR EACH S S, TV. (2) ANCHORS FER ANCHOR ;•/ SCHEDULE SUBSTRATE PER ANCHOR 'ri / /r • = `�'' r SCHEDULE (VARIES) 2" TIE -DOWN CLIP 4 ANCHOR DETAIL DETAIL CLIP IS DESIGNED FOR PULL ' CONTAC7 Wlrit THE RASE OF EACH MECHANICAL UNIT, TYP. 7 ° i D n m 9 i c) F f z ? a LLlgaa a o z a ° m ll-BMP-0001 I 4 RING Product Evaluation Report November 4, 2011 Application Number: FL #14239 FLB Project Number: 11-BMP-0001-01 Product Manufacturer: BMP International Manufacturer Address: 4710 28th Street North St. Petersburg, FL 33714 Product Name: Slotted Steel Tie -Down Clips, 1" and 2" Models Product Description: Steel Tie -Down Clip System (For Use with Mechanical Units at Roof or Grade) Scope of Evaluation: This.Product Evaluation Report is being issued in accordance with the requirements of the Florida Department of Community Affairs (Florida Building Commission) Rule Chapter 9N-3.005, F.A.C., for - statewide acceptance per Method 1(d). i The product noted above has been tested and/or evaluated as summarized herein to show complianc6 with the 2010 Florida Building Code and is, for the purpose intended, at least equivalent to that required by the Code. Re-evaluation of this product shall be required following pertinent Florida Building Code modifications or revisions. Substantiating Data: G PRODUCT EVALUATION DOCUMENTS FLB drawing #11-BMP-0001-01 titled "Mechanical Unit Steel Tie -Down Clip Capacities: At -Grade and Roof -Top Mounted Applications", sheet'.§ 1-4, prepared by Engineering Express, signed & sealed by Frank L. Bennardo, P.E. is an integral part of this Evaluation Report. o TEST REPORTS I Ultimate test loading structural performance has been tested. in accordance with ASTM D1761-88 test standards per test report(s) #TEL 01970387A and #TEL 01970387D by Testing. Evalu a tio n, -aboratories, Inc. 0.�v".'i)e, a STRUCTURAL ENGINEERING CALCULATIONS Kepsea Pnginear ,,ppa?�es �t th Structural engineering calculations have been prepared which based on comparative and/or rational - evaluate the product analysis to qualify the fallowing design criteria: 1. Maximum Allowable Unit Wind Pressures"� • 2. Minimum Allowable Unit Width FratiiT LE 'en 3. Maximum Allowable Unit Height # PE, Q, 4. Minimum Unit Weight °4s ,_. 5. Maximum Allowable Unit Surface Area n , 6. Clip Configuration and Anchor Spacing 7. Anchor Capacity for Various Substrates 160 SW 12T" Av.ENUE #106 DEERFIELD BEACH, FL 33441 PHONE: 954-354-0660 r-Ax: 954-354-0443 WWW.ENGExP.COM „EXPRESS'' NovemUel• 4, 20l 1 BMP INTERNATIONAL -SLOTTED STEEL TIEDOWN CLIPS 1"/2” Page 2 of 2 8, Maximum Allowable Additional Uplift per Clip in Combination with Lateral Forces (For Use with Rooftop Applications) .. -....-No 33% increase in allowable stress has been used in the design of this product. Impact Resistance; Not applicable to this product. Wind Load Resistance This product has been designed to resist wind.loads as indicated in the design schedule(s) on the Product Evaluation Document (i.e. engineering drawing). Installation The product listed above shall be installed in strict compliance with the Product Evaluation Document (i.e. engineering drawing), along with all components noted therein. The product components shall be of the materlal specified in the Product Evaluation Document (i.e. engineering drawing). Limitations & Conditions of Use: Use of this product shall be in strict accordance with the Product Evaluation Document (i.e. engineering drawing) as noted herein. All supporting host structures shall be designed to resist all superimposed loads and shall be of a material listed in this product's respective anchor schedule. Host structure conditions which are not accounted for In this product's respective anchor schedule shall be designed for on a site -specific basis by a registered professional engineer. All components which are permanently ;installed shall be protected against corrosion, contamination, and other such damage at all times, This product has been designed for use within the High Velocity Hurricane Zone (HVHZ). 160 SW 12T" AVENUE #106 DEERFIELD BEACH, FL 33442 PHoNe: 9541-354-0660 FAX: 954-354-0443 WWW.ENGEXP.COM Residential System Sizing Calculation Summary Project Title: 7946 STEEPLECHASE COURT BALCHUNAS RESIDENCE PORT ST LUCIE, FL 1/27/2014 Location for weather data: Fort Pierce, FL - Defaults: Latitude(27.48) Altitude(25 ft.) Temp Range(L) Humidi data: Interior RH 50% Outdoor wet bulb 78F Humidity difference 64 r. Winter design temperature(MJ8 99%) 42 F Summer design temperature(MJ8 99%) 90 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 28 F Summer temperature difference 15 F Total heatinq load calculation 26146 Btuh Total cooling load calculation 28197 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 112.1 28200 Sensible (SHR = 0.75) 93.1 21600 Heat Pump + Auxiliary(O.OkW) 112.1 28200 Latent 144.3 7200 Total Electric Heat Pump) 102.1 28800 WINTER CALCULATIONS lAlintar Waatinn I nnri (fnr 11RR cnft) Load component Load Window total 288 sqft 7731 Btuh Wall total 964 sqft 4030 Btuh Door total 48 sqft 618 Btuh Ceiling total 1158 sqft 1033 Btuh Floor total 1158 sqft 7071 Btuh Infiltration 61 cfm 1873 Btuh Duct loss 2790 Btuh Subtotal 25146 Btuh Ventilation 0 - cfm 0 Btuh TOTAL HEAT LOSS 25146 Btuh Q"mmor !`nnlinn I Hari (fnr 11 RR snftl RooraCZ SUMMER CALCULATIONS Load component Load Window total 288 sqft 11585 Btuh Wall total 964 sqft 2159 Btuh Door total 48 sqft 662 Btuh Ceiling total 1158 sqft 1623 Btuh Floor total 0 Btuh Infiltration 46 cfm 753 Btuh Internal gain 2490 Btuh Duct gain 3935 Btuh Sens. Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Total sensible gain 23206 Btuh Latent gain(ducts) 1406 Btuh Latent gain(infiltration) 1985 Btuh Latent gain(ventilation) 0 Btuh Latent gain(intemal/occupants/other) , 1600 Btuh Total latent gain 4991 Btuh TOTAL HEAT GAIN 28197 Btuh Latent intemal(6%) Int.G DUCM(19%) inrL EnergyGauge®Syst m S' i g PREPARED BY: DATE: Z / EnergyGauge® / USRFZB v3.1 itlows(31%) :itn4s(<%) NinGow3(41%) st Wn Calculations = Summer Residential Load - Room by Room Component Details Project Title: 7946 STEEPLECHASE COURT BALCHUNAS RESIDENCE PORT ST LUCIE, FL 1 /27/2014 Reference City: Fort Pierce, FL Temperature Difference: 15.OF(MJ8 99%) Humidity difference: 64gr. Component -Loads for.Room #1: Main Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross Shaded Unshaded Shaded Unshaded 1 1 NFRC 0.50, 0.96 No No SW 7.Oft 1.0ft 22.5 22.5 0.0 25 50 565 Btuh 2 1 NFRC 0.50, 0.96 No No SW 8.Oft 1.0ft 10.0 10.0 0.0 25 50 251 Btuh 3 1 NFRC 0.50, 0.96 No No SE 5.Oft 1.0ft 64.0 62.4 1.6 25 50 1645 Btuh 4 1 NFRC 0.50, 0.96 No No SW 1.0ft 1.0ft 45.0 6.8 38.2 25 50 2064 Btuh 5 1 NFRC 0.50, 0.96 No No SE 1.0ft 1.0ft 17.8 2.0 15.7 25 50 832 Btuh 6 1 NFRC 0.50, 0.96 No No NW 1.0ft 1.0ft 12.0 0.0 12.0 25 49 582 Btuh 7 1 NFRC 0.50, 0.96 No No NW 1.0ft 1.0ft 30.0 0.0 30.0 25 49 1456 Btuh 8 1 NFRC 0.50, 0.96 No No NE 1.0ft 1.0ft 53.3 0.0 53.3 25 49 2588 Btuh 9 1 NFRC 0.50, 0.96 No No NE 16.Of 1.0ft 18.0 0.0 18.0 25 49 874 Btuh 10 1 NFRC 0.50, 0.96 No No NE 1.0ft 1.0ft 15.0 0.0 15.0 25 49 728 Btuh Window Total 288 (sqft) 11585 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 292.5 2.2 655 Btuh 2 Concrete BIk,Hollow - Ext 0.15 4.1/0.0 20.0 2.2 45 Btuh 3 Concrete BIk,Hollow - Ext 0.15 4.1/0.0 198.0 2.2 443 Btuh 4 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 30.0 2.2 67 Btuh 5 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 175.7 2.2 393 Btuh 6 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 50.0 2.2 112 Btuh 7 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 138.2 2.2 309 Btuh 8 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 60.0 2.2 134 Btuh Wall Total 964 (sqft) 2159 Btuh Doors Type Area (sqft) HTM Load 1 Insulated - Exterior 48.0 13.8 662 Btuh Door Total 48 (sqft) 662 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Vented Attic/Light/Shingle 0.032 30.0/0.0 1158.0 1.40 1623 Stuh Ceiling Total 1158 (sqft) 1623 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 1158 (ft-perimeter) 0.0 0 Btuh Floor Total 1158.0 (sqft) 0 Btuh Zone Envelope Subtotal: 16028 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Load Natural 0.26 10422 1.00 45.6 753 Btuh Internal Occupants Btuh/occupant Appliance Load gain 8 X 230 + 650 2490 Btuh Sensible Envelope Load: 19271 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Attic) (DGM of 0.204) 3935 Btuh Sensible Zone Load 23206 Btuh EnergyGauge® / USRFZB v3.1 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate: FL_ST LUCIE_CO_INTL 7946 STEEPLECHASE COURT BALCHUNAS RESIDENCE PORT ST LUCIE, FL 1 /27/2014 EnergyGauge®/ USRFZB v3.1 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate: FL_ST_LUCIE_CO_INTL 7946 STEEPLECHASE COURT BALCHUNAS RESIDENCE PORT ST LUCIE, FL WHOLE HOUSE TOTALS 1/27/2014 Sensible Envelope Load All Zones 19271 Btuh Sensible Duct Load 3935 Btuh Total Sensible Zone Loads 23206 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 23206 Btuh Totals for Cooling Latent infiltration gain (for 64 gr. humidity difference) 1985 Btuh Latent ventilation gain 0 Btuh Latent duct gain 1406 Btuh Latent occupant gain (8.0 people @ 200 Btuh per person) 1600 Btuh Latent other gain 0 Btuh Latent total gain 4991 Btuh TOTAL GAIN 28197 Btuh EQUIPMENT 1. Central Unit # 28800 Btuh "Key: Window types (Panes - Number and type of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value) (U - Window U-Factor) (InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half closed For Roller shades: Assume translucent, half closed (IS - Insect screen: none(N), Full(F) or Half('/)) (Ornt - compass orientation) EnergyGauge® / USRFZB v3.1 Page 3