Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS- - L ALL APPLICABLE INFO MUST BE COIF, LETED FOR APP-LICATI6N TO BE ACCEPTEv j Date: ! ' 1 `J Permit Number: 6L;HNN ED 8Y • Si. Lucie Cr Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial PERMIT APPLICATION FOR: Roof ,PROPOSED IMPROVEMENT LOCATION: Address: 580 LA BUONA VITA DR. PORT ST. LUCIE, FL 34952 Legal Description: LA BUONA VITA COOPERATIVE UNIT/LOT 51 (OR 1431-2693) Property Tax ID #: 3426-664-0051-000-9 Site Plan Name: Project Name: Setbacks Front Back: Right Side: Left Side: DETAILED DESCRIPTION OF WORK: Residential XoXXocx REMOVE EXISTING ROOF & REPLACE ANY ROT INSTALL TWO LAYERS OF ASTM-226 30# UNDERLAYMENT INSTALL 130 MPH ARCHITECTURAL SHINGLES Lot No. 51 Block No. CONSTRUCTION INFORMATION: Additional work to eperformed—un er Rs permit — check a app y: 0HVAC Gas Tank ❑Gas Piping Shutters Q Windows/Doors 11 Electric ❑ Plumbing OSprinklers Generator E]Roof Total Sq. Ft of Construction: 1,400 S Ft. of First Floor: Cost of Construction: $ 5,800 Utilities.: Sewer Eleptic Building Height: OWNER/LESSEE: CONTRACTOR: Name GERARD CROTEAU Name: JOE BAKER Company: BIG LAKE ROOFING & REPAIRS Address: 580 LA BUONA VITA DR. City: PORT ST. LUCIE State: FL Zip Code: 34952 Fax- Phone No. 772-879-3137 Address: 2699 NW 16TH BLVD. City: OKEECHOBEE State: FL Zip Code: 34972 Fax: 863-763-7662 Phone No. 863-763-7663 E-Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail: BIGLAKEROOFING@YAHOO.COM State or County License: CCCO46939 IF value or construction is azsuu or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUC7`TO;fU LIEN.LAW INFORMATION: DESIGNER/ENGINEER: xxx Not Applicable MORTGAGE COMPANY: xxx Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: xxx Not Applicable BONDING COMPANY: xxx Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend 'to obtain financing, consult with lender or an attorney before commencing work or recording your Notice of Commencement. Signature of Owner/ Agent/ Lessee Signature of Contractor/License Holder STATE OF FLOSTATE OF FLO A COUNTY OF L�Q -P fJ SJ n .Q COUNTY OF /tom The f r mg instrument was acknowledged before me The for oing instrument was acknowledged before me this day of 20 _K by this day of 20AS by (Name of person acknowledging) (Name of person acknowledging ) (Signature of Notary Public- State of Florida) (Signature of Notary Public- State of Florida ) Personally Known OR Produced Identification Type of Identification Produced Commission No. 41 1/ �. Heatlsl y"00 Comm� FF125216 cYaRS MW 21. 2018 Revised 07/15/201 Personally Known OR Produced Identification Type of Identification Produced Commission No. HMS' Edwardson commWON i FF125216 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS JOSEPH E. SMITH, CLERK_ OF THE CIRCUIT COURT — SAINT LUCIE CotnJmY FILE # 4028423 OR E'- ' 3705 PAGE 537, Recorded 01/06/2015; 11:54 AM NOTICE OF COMMENCEMENT Permit: No. Tax Folio No, 3426-664-0051-000-9 State of Florida County of St. Lucie The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. Legal Description of Property: (and street address If available): LA RUONA VITA COOPERATIVE IJNITA-0151 (OR 1d11-769A1 General description of Improvement: RF-ROOF Owner information or Lessee Information If the Lessee contracted for the improvement: Name GERARD CROTEAU Address 580 LA BUONA VITA DR. PORT ST. LUQF. FL 34952 Interest in property: OWNER Name and address of fee simple titleholder (if different from Owner listed above): Contractors Name: RIG LAKE ROOFING P REPAIR Contractor Address:2699 NW 167H BLVD pKEE -HOB FL 34972 Phone Number: 863-763,7668 Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ Name and address: NtA Phone number: Lender Name: _NIA Phone Number: Lender's address: Persons within the State of Florida designated by Owner upon whom notices or other documents may he served as provided by Section 7M.13(1) (a)7., Florlda statutes: Name: Phone Number: In addition to himself or herself, Owner designates of Uenors Notice as provided In Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 yearfrom the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OFTHE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTSTO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SiTE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my kno edge and bellef. X C (Signature of Owner or Lessee, or Owner's or Lessee's Authorized Ofricer/Director/partner/Manager is 91E1-PrIZO (2RO-TiFfAL) (Signatory's Title/Office) '' CC The foregoing Instrument was acknowledged before me this -day of�YL_ , 20� Bv_6k?AC6Lnd rX A-0-Pa I as for Name of Person Type of authority (e.g. o[ffi(c�er,,,ttrjustette) Party on behalf of whom instrument was executed L� r� Heo EdW8fdW Personally known, or produced Identification Signature of Notary Public - State of Florida) # F0208 (Print, Type, orStamp Commissioned Name of N 44% 1 21, 2818Type of Identification produced 1 `°� y��glNorMY.cai STATE OF FLORIDA ST. LUCI OUNTY THIS 1 CERTIFY THAT THIS IS JTRUNCORRECT COPY OF K Date: jj4c Gerard A Croteau Record: 1 of 1 Property Identification Site Address: 580 La Buona Vita Dr Sec(Town/Range: 26 :36S :40E Map ID: 34/26S Zoning: RMH-5 Ovanersirip and Alailing Owner. Address: PROPERTY RECORD CARD —Prev Next >> Spec.Assmnt Taxes ParcelID: 3426-664-0051-000-9 Account#: 146008 Use Type: MobHome-Coop City/Cnty: Saint Lucie County Exemptions Permits Flome Print v, 00 .. Legal Description Gerard A Croteau Ann R Croteau LA BUONA VITA COOPERATIVE UNIT/LOT 51 (OR 1431-2693) 580 La Buona Vita Dr Port St Lucie FL 34952 Sales Information Date Price Code 7/10/2001 100 01 5/31/2001 4450000 00 Assessment 2014 Deed Book/Page 2014 TRIM: 38100 MS 1431 / 2693 Assessed: 38100 WD 1398 / 1783 Ag.Credit: 0 Exempt: 38100 Taxable: 0 Taxes: 156.87 IILIILDING INFORMATION Total Land and Building Land Value: 15000 Acres: 0.05 Building Value: 23100 Finished Area 1250 SgFt Exterior Features View: - RoofCover. - RoofStruct: - ExtType: MHA - MHA YearBft: 1988 Frame: - Grade: LABV - LaBuonaV MH EffYrBlt: 1988 PrimeWall: - StoryHght: 0010 - 1 Story No.Units: 1 Secwdl: - Interior Features BedRooms: 0 Electric: - PrmintWall: FullBath: 0 HeatType: FHA - FrcdHotAir AvgHt/Fl: 1/2Bath: 0 HeatFuel: ELEC - Electric Prrn.Flors: - %A/C: 100 %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Use Type Type Measure Depth 1 0205-MobHome-Coop III -Site 1 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. Florida (3 partmentq� BCIS Home j Log to i User Registration Hat Topics t Submit Surcharge Statr &Facts Publications I FBC Staff I BCIS Site Map Links i Search Busines(l� ) Professi � `�� product Approval USER: Public User Regulation Product Approval Menu > Product or Aooliation Search > Application List > Application Detail .M,. FL # FL12328-R3 Application Type Editorial Change Code Version 2010 Application Status Approved Comments Archived O Product Manufacturer TAMKO Building Products, Inc. Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417) 624-6644 Ext 2305 kerri_eden@tamko.com Authorized Signature Kern Eden kerrt_eden@tarrLko.com Technical Representative Kerri Eden Add ress/Phone/Erreil PO Box 1404 Joplin, MO 64802 (417) 624-6644 Ext 2305 kerri—eden@taniko.com Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Testing Lab Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Subrrdtted Date Validated Date Pending FBC Approval Date Approved Roofing Underiayments Test Report PRI Construction Materials Technologies, LLC UL LLC \ 02/26/2016 Robert J. M. Nieminen, PE O Validation Checklist - Hardcopy Received FL12328 R3 COI PRI CMT Cert of Indeoendence.odf Standard Year ASTM D1970 2001 ASTM D226 2006 ASTM D4869 2005 ASTM D6380 2003 Method 1 Option B 03/04/2013 03/11/2013 04/15/2013 06/11/2013 BUILDING PRODUCTS UNDERLAYMENT: An underlayment consisting of asphalt saturated felt must be applied over the entire deck before the installation of TAMKO shingles. Apply the felt when the deck is dry. On roof decks 4 in. per foot and greater apply the felt parallel to the eaves lapping each course of the felt over the lower course at least 2 in. Where ends join, lap the felt 4 in. If left exposed, the underlayment felt may be adversely affected by moisture and weathering. Laying of the underlayment and the shingle application must be done together. CORPORATE HEADQUARTERS 220 W. FOURTH STREET P.O. BOX 1404 JOPLIN, MO 64802-1404 800-641-4691 tamko.com N.nwE .-,lk't . ACCRBDrml) CONSTRUCTION MATERIALS TECH:NOLOGiES LABORTOFtY TEST ;REPORT Report for: Tamko' Building Products, Inc. '220 W. 4th Street Joplin, MO 64802 Attention: . Kerri Eden .Date: January 8, 2009 Product Name: No. 30 ASTM Manufacturer: Tamko Date Received: December 31, 2008 Source: Tamko PRI Report No.: TAP-215-02-W Metro -Dade Notification No.: PRI08122 Subject: The purpose of this project was to performance properties of Tamko Building Products No. 30 ASTM (No. 30, Type 11) asphalt felt for compliance with Florida Building Code 2004 and 2007 (HVHZ) Testing Application Standard (TAS) 110-2000: TESTING REQUIREMENTS FOR PHYSICAL PROPERTIES OF ROOF MEMBRANES, INSULATION, COATINGS, AND OTHER ROOFING COMPONENTS, Section 2.2: Roofing Components within asphalt built-up and modified bitumen roof assemblies, and. Florida Building Code 2004 and 2007; Sections 1507.2.3, 1507.3:3; 1507..5.3, and 1507.7.3: Underlayment using ASTM D 226-97a and ASTM D 226-06: Standard Specification forA. sphalt Saturated Organic Felt Used in Roofing and Waterproofing,- Type II. Test Methods: The test methods used included those. found in' F13C TAS 116-2000: TESTING REQUIREMENTS FOR PHYSICAL PROPERTIES OF ROOF MEMBRANES, lIUSULATION, COATINGS, AND OTHER ROOFING COMPONENTS and including: ASTM D 226: Standard Specification forAsphalt-Saturated Organic Felt Used in Roofing and Waterproofing; ASTM D 146:. Standard Test Methods for Sampling and. Testing Bitumen -Saturated Felts and Woven Fabrics for Roofing and Waterproofing; ASTM D 727: Test Method for Kerosine Number of Roofing and Flooring Felt by the Vacuum Method. Sample - The sample received from Tamko Building Materials on December 31, 2008 was a full factory Description:'- labeled roll of felt. TAP-215412-01 PRI Acdeditations• IAS-ES TL-189; State of Florida. TST5878; Metro -Dade 06-111602; CRRC The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusfve.use of stated client. No reproduction orfacsimile in anyform can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies, LLC. assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report PRI Construction Matey & Tedmftgies. LLC. 6408 Badger Drive Tampa. FL 33610 Tel: 813.6215n7 Fac 8t3-621-M email mAdalstasting.@;dic rem W&SM htWMiwx,.pricmtmm Tamko Building Products Laboratory Test Report for No. 30 ASTM Saturated Felt PRI08122 Page 2 of 2 Results of Testina: Property • 211 26 Type Result .. . Requirement 5- Materials and Manufacture D 226 Pass Free of Lumps or particles or foreign substances Physical Requirements Table6. 6.1 Average breaking:strength, Ibf/in Dt46 = - MD 69 40 min CMD 28 20 min Pliability @ 770F D 146 Pass No cracking Loss on heating @ 221 °F, % D 146 2.7 4 max Width of roll, in D 146 36.0 36 t 0;7°favor as?axeed' Area of roll, ft.2 D 146 216.7 2 t6 oc432 rrttQrasgree Moisture at point of manufacture, % D 146 3.2 Net mass of saturated felt, lb/100 ff D 146 28.0 26;mirk_ t� Mass of saturant, Ib/100 fe D 146 17.4 Mass of desaturated felt, Ib/100 ff D 146 10.8 x}tinlr ��' Ash, % D 146 4.5..�0� Saturation, % D 146- 6.2 Unroll @ 50 and 140°F D 226 6.3 Perforated felt D 226 7 Workmanship,. Finish, D 226 Pass= .affi Appearance . Note 1: Or as agreed upon by purchaser and -seller. Statement of Compliance: This product complies with all of the requirements of Florida Building Code 2004 and 2007. (HVHZ).Testing Application Standard (TAS) 110-2000: TESTING REQUIREMENTS FOR PHYSICAL PROPERTIES 01= ROOF MEMBRANES, INSULATION, COATINGS, AND OTHER ROOFING COMPONENTS, Section 2.2: Roofing Components within asphalt built-up and modifiedbitumen roof assemblies,.and.Flodda Building Code 2004 and 2007; Sections 1507.2.3, _1507.3.3, 1507.5.3, and 1507.7.3: Underlayment using ASTM D 226-97a: Standard Specification forAsphalt-SaturatedOrganic Felt Used in Roofing and Waterproofing, Typell. The product also complies with all of the requirements of-ASTM D 226-06: Standard Specification forAsphalt- Saturated Organic Felt Used in Roofing and Waterproofing, Type 11. Limitations: None. Signed - Donald C. P olio President Date: Signed: C Duc T. Ngu _1 Florida Registered Profq onal Engineer P. E.:Number: 65034 TAP-215-02-01 PRI Accreditation: IAS-ES TLA M. State of Florida TST5878; Metro -Dade. 06-1116.02; CRRC The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive, use of stated client: No reproduction orfacsiinile in anyform can be made without the client`s permission. This report shall not be reproduced except in full without the written approval of this laboratory_ PRI Construction Materials Technologies. LLC. assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing. this material in connection with this report PRI Comtruciiw Materials Tectmologles, LLC. 6408 Badger Drive Tampa FL 33610 TeL 813-621ZTR F= 813-621-5W e4n80 materialstestimg@Prkntcom WebSitrr h JNmw.pricmtcom TAMK06 NO•30 UL PRODUCT DATA Asphalt Saturated Organic Felt W Manufactured in Joplin, MO, Frederick, MD, and Green Cove Springs, FL TAMKO° NO. 30 UL SATURATED FELT features a tough TAMKO organic felt that is saturated with asphalt. Accepted for use as an underlayment felt to be applied over the roof deck prior to the installation of TAMKO asphalt shingles. smn�[aRannv� -- U.L. Built -Up Type 30 Label ASTM D 226, Type II Roll Dimensions 72' X 36" - - Coverage per roll 2 Squares Laying Lines 2", 4", 17" 'All values stated as nominal THIS PRODUCT IS SOLD "AS IS" WITHOUT WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Visit our Web Site at tamko.com AUiION: This product contains wood dust N.bcd dust has been dassfiad as a `imcrW human cardragen by the Irrational Agency for Researc n Cancer ([ARC) and the National Toxicology Program This product also confairs owdized asphalt Occupational e)ipostres to oxidized asphalt and B missiersduringreofmghave been classified by[ARCasa'probab[ehurnaicar=rogen".Ondzedaspha[tdmcatwsPelycyrlicAr tabcHydomrbor weofvvli havebeen dassiliiedbyIARCasknownorprobablehumancaranogarsThe physical nature ofth"sproduct mayhelprarutany mfhalabon< lerrral hazard duainga� and(crrarewal. Havaver, physcal torcm&ich as sawwS 4mdrx3 ordffz9 ding daTc[ton vvakard heating orburn6u my haeasethe inhalation or dermal aposure hazard ofths produd.Takeprecathorsto prevent tithing and mrtactvrith skm Central District 220 West 4th St. Joplin, MO 64801 800-641-4691 Northeast District 4500 Tamko Dr. Frederick, MD 21701 800-368-2055 BUILDING PRODUCTS Southeast District 2300 35th St. Tuscaloosa, AL 35401 800-228-2656 Southwest District 7910 S. Central Exp. Dallas, TX 75216 800-443-1834 TAMKO Logo, Roofer toga and TAMKO9 Western District 5300 East 43rd Ave. Denver, CO 80216 800-530-8868 are registered trademarks of TAMKOa Building Products, Inc. Information included in this product data sheet was current at time of printing. To obtain a copy of the most current version of this product data sheet, visit us online at tamko.com or call us at 800-641-4691. Rev. 0512012 FW?APA,0RPAFlTM3NT OF �1 Business ♦ ♦ 9 Y. • R', 4 gdaDepartments BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Seartirsines Professi IOUSER: Product Approval Regulation Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email FL10674-R9 Revision 2010 Approved Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Greg Keeler greg.keeler@owenscorning.com Mel Sancrant 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer idl Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code PE-59166 UL LLC 07/17/2017 John W. Knezevich, PE Validation Checklist - Hardcopy Received FL10674 R9 COI 2014 01 COI Nieminen.pdf Standard ASTM D3161, Class F ASTM D3462 ASTM D7158, Class H Year 2006 2007 2007 TRINITY EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 ER® OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 Evaluation Report 037940.02.12-114 FL10674-R9 Date of Issuance: 02/06/2012 Revision 4: 03/04/2014 SCOPE: This Evaluation Report is issued under Rule 914-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED. COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to Updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrihityJERD Evaluated" may be displayed in advertising, literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 03/04/2014 This does not serve as an electronically signed document Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named dient CERTIFICATION of INDEPENDENCE: 1. TriniMIERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products It evaluates. 2: TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nleminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. TFUNIIY ERD ROOFING SysTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Propertv Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 3. REFERENCES: Entity Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation R2453 Exp. 09/26/2014 4. PRODUCT DESCRIPTION:. 4.1 Asphalt Shingles: 4.1.1 Classic® and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 DevonshireTm are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration®, TruDefinition® Duration®, Duration® Premium Cool, TruDefinition® Duration® Designer Color Collection, TruDefinition® OakridgeO, OakridgeO and WeatherGuardO HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire°) Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuardO HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeTm Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certitieate of Authorization &9503 FL10674-R9 Revision 4: 03/04/2014 Page 2 of 7 i J TRINITY ERD 5.3.1 All Owens Coming shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (VW, = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.2 All Owens Coming hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vad = 150 mph (VWt = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to -each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Coming and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire® shingles require minimum five (5) nails per shingle. ➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle. ➢ Devonshire TM shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization #9503 FL10674-119 Revision 4: 03/04/2014 Page 3 of 7 6.2.5 Minimum Nailing — Classic@ & Supreme: Normal Mansard or Area pare Mfind Areas High Wind desvanes y Area paw vientos normales Anus vientos f cartes t-tt• (A) tt,t• rt• 2-i (B 2• t. 6°Exposure Ezposiaibn 6.2.6 Minimum Nailing — BerkshireO: Seatard strip !a ttra de seW r sit, 9 Vf I 9'Yf I 8 w, t 6.2.7 Minimum Nailing — Devonshire TM: -,I TPJNITY I ERD Normal Mansard or Area paw Wind Areas High Wind desvames y Area paw vientos normales Areas vientos foertes t2 t21 T r 2', (B 2- t- 5 51 ' Exposure Exposleibn Sealant strip to Lira de seikrbr •� Otip—f• 9.4 be- *0 8Yt' B.Yt 8'� r t" r r� A- P4Wmk Footing cement Cem Wdeteehadeaslab Nails r e r 13-W •Y Ten 1" Spots of Asphalt Roof Cement 6.2.8 Minimum Nailing — Duration@, TruDefinition(g) Duration, Duration@ Premium Cool & TruDefinition° Duration° Designer Color Collection: 6 Nai bnsatd and stied supe fasten 'between SuaNai Main areaandlep dMud. F_S Wwm — 9bnsa& opadsatrs do SdaVas arAlasRpdaeerned •. • • SaeMal®y6pxb stpaiadrlraafe. i bnnrg�g;Sur&P arawuth. attaNiaia Awade r \ dt su rblo 7r ^ .dr• ` S emiP LiE SW Exposure Naas SW Exposue S%polg. de exposkide Cla►6s Y%pudg. de uMsloldn Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-114 Certificate of Authorization #9503 FL10674-119 Revision 4: 03/04/2014 Page 4of7 6.2.9 Minimum Nailing — TruDefinitionO Oakridge0, OakridgeO: 4 Nall Pattom Esquema con 4 davos 5W EXPM! apos1d 55/8pidg 6Nags Erposf 55/8prdg 6.2.10 Minimum Nailing — WeatherGuard® HP: 6.3 Hip & Ridge Shingles: \,I I RINI7Y ERD 6 Nall PaK¢m Esquema can 6 davos rr 55Ar gpgsme �� 55%"Egxmje brposidou.debWBpdg Expasiadade &5/Sprdg 11/bb IrErd R�7lm� N� IJb 6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuardO HP Hip and Ridge Shingles and Pro Edge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidgeT"' Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization #9503 FL10674-119 Revision 4: 03/04/2014 Page 5 of 7 6.3.3 6.3.4 6.3.5 Minimum Nailing - Berkshire@ Hip & Ridge and High Ridge: Fig. 1 q <— Pmraltmwste WeWun A Nags A A I I I I A I I 4 I I 1 1 1 I A i i t 1 �e `.t TjtlNfjYIERD FIg.2 Top View _SiUeView. Naffs .Nails 7__ TOP Lanila[ed r 7. 4- Piew Y 1 1 I 4 ml SI 1 ml, VI 1 I I 1 Minimum Nailing - Hip & Ridge with Sealant: earn Fig., 2 : High W kW Fas elnittg Fatten �� Nailsj rim Shingle Discard 2,.�,� brae 7•' ,1,. Se�lairrt =� ..Strip 12" ' Fas466 i rg: 5 �}s S ,• Expasu Dina 12 ,1.. Minimum Nailing - WeatherGuard@ HP Hip and Ridge: Fig. A 9 1? Pt4�raEhlg raw <- Dllat3bn A Halls` 4 4 " I I A I I I I I AA I I I I Eiposure Fig. C Hip & Ridge. Shingle Fastening Topvlm Naps Nails T' 7 2- j. �. G. Elposure I 17' Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization #9503 FL10674-119 Revision 4: 03/04/2014 Page 6 of 7 6.3.6 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Wind Direction Sealant Strip 6' Exposure Fasten Th' Cover Exposed Fasteners with Roof Cement F)o \,JTPJNITYI ERD Standard Fastening �17._► Pattern I` 12' Sealant I h 6" Exposure 6.3.7 Minimum Nailing — DuraRidgeTm Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. — D�cti nddornimi adjYmt Di�C=dalvimto prodornimnto Naib —� n �IaIA 1 1 C1aas� 4 I I 1 1 It P 7. LABELING: Top View Vac en plan I�. Vista superior 1"IH T � S Goo OVmm Coning Sumtlad•' Cf.o u i i 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625 ; (414) 248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization #9503 FL10674-119 Revision 4: 03/04/2014 Page 7 of 7