HomeMy WebLinkAboutSUBMITTED PAPERS- - L
ALL APPLICABLE INFO MUST BE COIF, LETED FOR APP-LICATI6N TO BE ACCEPTEv j
Date: ! ' 1 `J Permit Number:
6L;HNN
ED
8Y
• Si. Lucie Cr
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial
PERMIT APPLICATION FOR: Roof
,PROPOSED IMPROVEMENT LOCATION:
Address: 580 LA BUONA VITA DR. PORT ST. LUCIE, FL 34952
Legal Description: LA BUONA VITA COOPERATIVE UNIT/LOT 51 (OR 1431-2693)
Property Tax ID #: 3426-664-0051-000-9
Site Plan Name:
Project Name:
Setbacks Front Back: Right Side: Left Side:
DETAILED DESCRIPTION OF WORK:
Residential XoXXocx
REMOVE EXISTING ROOF & REPLACE ANY ROT
INSTALL TWO LAYERS OF ASTM-226 30# UNDERLAYMENT
INSTALL 130 MPH ARCHITECTURAL SHINGLES
Lot No. 51
Block No.
CONSTRUCTION INFORMATION:
Additional work to eperformed—un er Rs permit — check a app y:
0HVAC Gas Tank ❑Gas Piping Shutters Q Windows/Doors
11 Electric ❑ Plumbing OSprinklers Generator E]Roof
Total Sq. Ft of Construction: 1,400 S Ft. of First Floor:
Cost of Construction: $ 5,800 Utilities.: Sewer Eleptic Building Height:
OWNER/LESSEE:
CONTRACTOR:
Name GERARD CROTEAU
Name: JOE BAKER
Company: BIG LAKE ROOFING & REPAIRS
Address: 580 LA BUONA VITA DR.
City: PORT ST. LUCIE State: FL
Zip Code: 34952 Fax-
Phone No. 772-879-3137
Address: 2699 NW 16TH BLVD.
City: OKEECHOBEE State: FL
Zip Code: 34972 Fax: 863-763-7662
Phone No. 863-763-7663
E-Mail:
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
E-Mail: BIGLAKEROOFING@YAHOO.COM
State or County License: CCCO46939
IF value or construction is azsuu or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUC7`TO;fU
LIEN.LAW INFORMATION:
DESIGNER/ENGINEER: xxx Not Applicable
MORTGAGE COMPANY: xxx Not Applicable
Name:
Name:
Address:
Address:
City: State:
City: State:
Zip: Phone:
Zip: Phone:
FEE SIMPLE TITLE HOLDER: xxx Not Applicable
BONDING COMPANY: xxx Not Applicable
Name:
Name:
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend 'to obtain financing, consult with lender or an attorney before
commencing work or recording your Notice of Commencement.
Signature of Owner/ Agent/ Lessee Signature of Contractor/License Holder
STATE OF FLOSTATE OF FLO A
COUNTY OF L�Q -P fJ SJ n .Q COUNTY OF /tom
The f r mg instrument was acknowledged before me The for oing instrument was acknowledged before me
this day of 20 _K by this day of 20AS by
(Name of person acknowledging) (Name of person acknowledging )
(Signature of Notary Public- State of Florida) (Signature of Notary Public- State of Florida )
Personally Known OR Produced Identification
Type of Identification Produced
Commission No. 41 1/ �. Heatlsl y"00
Comm� FF125216
cYaRS MW 21. 2018
Revised 07/15/201
Personally Known OR Produced Identification
Type of Identification Produced
Commission No.
HMS' Edwardson
commWON i FF125216
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
JOSEPH E. SMITH, CLERK_ OF THE CIRCUIT COURT — SAINT LUCIE CotnJmY
FILE # 4028423 OR E'- ' 3705 PAGE 537, Recorded 01/06/2015; 11:54 AM
NOTICE OF COMMENCEMENT
Permit: No. Tax Folio No, 3426-664-0051-000-9
State of Florida County of St. Lucie
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,
the following information is provided in this Notice of Commencement.
Legal Description of Property: (and street address If available):
LA RUONA VITA COOPERATIVE IJNITA-0151 (OR 1d11-769A1
General description of Improvement: RF-ROOF
Owner information or Lessee Information If the Lessee contracted for the improvement:
Name GERARD CROTEAU
Address 580 LA BUONA VITA DR. PORT ST. LUQF. FL 34952
Interest in property: OWNER
Name and address of fee simple titleholder (if different from Owner listed above):
Contractors Name: RIG LAKE ROOFING P REPAIR
Contractor Address:2699 NW 167H BLVD pKEE -HOB FL 34972 Phone Number: 863-763,7668
Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $
Name and address: NtA Phone number:
Lender Name: _NIA Phone Number:
Lender's address:
Persons within the State of Florida designated by Owner upon whom notices or other documents may he served as provided by Section
7M.13(1) (a)7., Florlda statutes:
Name: Phone Number:
In addition to himself or herself, Owner designates of
Uenors Notice as provided In Section 713.13(1) (b), Florida Statutes.
Phone number of person or entity designated by owner
to receive a copy of the
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 yearfrom the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OFTHE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTSTO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SiTE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of
my kno edge and bellef.
X C
(Signature of Owner or Lessee, or Owner's or Lessee's Authorized Ofricer/Director/partner/Manager
is 91E1-PrIZO (2RO-TiFfAL)
(Signatory's Title/Office) '' CC
The foregoing Instrument was acknowledged before me this -day of�YL_ , 20�
Bv_6k?AC6Lnd rX A-0-Pa I as for
Name of Person Type of authority (e.g. o[ffi(c�er,,,ttrjustette) Party on behalf of whom instrument was executed
L� r� Heo EdW8fdW Personally known, or produced Identification
Signature of Notary Public - State of Florida) # F0208
(Print, Type, orStamp Commissioned Name of N 44% 1 21, 2818Type of Identification produced
1 `°� y��glNorMY.cai
STATE OF FLORIDA
ST. LUCI OUNTY
THIS 1 CERTIFY THAT THIS IS
JTRUNCORRECT COPY OF
K
Date: jj4c
Gerard A Croteau Record: 1 of 1
Property Identification
Site Address:
580 La Buona Vita Dr
Sec(Town/Range:
26 :36S :40E
Map ID:
34/26S
Zoning:
RMH-5
Ovanersirip and Alailing
Owner.
Address:
PROPERTY RECORD CARD
—Prev Next >>
Spec.Assmnt Taxes
ParcelID:
3426-664-0051-000-9
Account#:
146008
Use Type:
MobHome-Coop
City/Cnty:
Saint Lucie County
Exemptions Permits Flome Print
v, 00 ..
Legal Description
Gerard A Croteau Ann R Croteau LA BUONA VITA COOPERATIVE UNIT/LOT 51 (OR 1431-2693)
580 La Buona Vita Dr
Port St Lucie FL 34952
Sales Information
Date Price Code
7/10/2001 100 01
5/31/2001 4450000 00
Assessment 2014
Deed Book/Page
2014 TRIM:
38100
MS 1431 / 2693
Assessed:
38100
WD 1398 / 1783
Ag.Credit:
0
Exempt:
38100
Taxable:
0
Taxes:
156.87
IILIILDING INFORMATION
Total Land and Building
Land Value: 15000 Acres: 0.05
Building Value: 23100
Finished Area 1250 SgFt
Exterior Features
View:
- RoofCover. -
RoofStruct: -
ExtType:
MHA - MHA YearBft: 1988
Frame: -
Grade:
LABV - LaBuonaV MH EffYrBlt: 1988
PrimeWall: -
StoryHght:
0010 - 1 Story No.Units: 1
Secwdl: -
Interior Features
BedRooms:
0
Electric:
-
PrmintWall:
FullBath:
0
HeatType:
FHA - FrcdHotAir
AvgHt/Fl:
1/2Bath:
0
HeatFuel:
ELEC - Electric
Prrn.Flors: -
%A/C:
100
%Heated:
100
%Sprinkled: 0
Special Features and
Yard Items
Land Information
Type Y/S
Qty. Units
Qual. Cond.
YrBlt. No. Use Type
Type Measure Depth
1 0205-MobHome-Coop III -Site 1
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
Florida (3 partmentq� BCIS Home j Log to i User Registration Hat Topics t Submit Surcharge Statr &Facts Publications I FBC Staff I BCIS Site Map Links i Search
Busines(l� )
Professi � `�� product Approval
USER: Public User
Regulation
Product Approval Menu > Product or Aooliation Search > Application List > Application Detail
.M,. FL # FL12328-R3
Application Type Editorial Change
Code Version 2010
Application Status Approved
Comments
Archived O
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kern Eden
kerrt_eden@tarrLko.com
Technical Representative Kerri Eden
Add ress/Phone/Erreil PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri—eden@taniko.com
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Testing Lab
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
Date Subrrdtted
Date Validated
Date Pending FBC Approval
Date Approved
Roofing
Underiayments
Test Report
PRI Construction Materials Technologies, LLC
UL LLC \
02/26/2016
Robert J. M. Nieminen, PE
O Validation Checklist - Hardcopy Received
FL12328 R3 COI PRI CMT Cert of Indeoendence.odf
Standard
Year
ASTM D1970
2001
ASTM D226
2006
ASTM D4869
2005
ASTM D6380
2003
Method 1 Option B
03/04/2013
03/11/2013
04/15/2013
06/11/2013
BUILDING PRODUCTS
UNDERLAYMENT: An underlayment consisting of asphalt saturated felt must be
applied over the entire deck before the installation of TAMKO shingles. Apply the felt
when the deck is dry. On roof decks 4 in. per foot and greater apply the felt parallel to the
eaves lapping each course of the felt over the lower course at least 2 in. Where ends join,
lap the felt 4 in. If left exposed, the underlayment felt may be adversely affected by
moisture and weathering. Laying of the underlayment and the shingle application must be
done together.
CORPORATE HEADQUARTERS
220 W. FOURTH STREET P.O. BOX 1404 JOPLIN, MO 64802-1404 800-641-4691
tamko.com
N.nwE
.-,lk't .
ACCRBDrml)
CONSTRUCTION MATERIALS
TECH:NOLOGiES
LABORTOFtY TEST ;REPORT
Report for: Tamko' Building Products, Inc.
'220 W. 4th Street
Joplin, MO 64802
Attention: . Kerri Eden
.Date: January 8, 2009
Product Name:
No. 30 ASTM
Manufacturer: Tamko
Date Received:
December 31, 2008
Source: Tamko
PRI Report No.:
TAP-215-02-W
Metro -Dade Notification No.: PRI08122
Subject: The purpose of this project was to performance properties of Tamko Building Products No.
30 ASTM (No. 30, Type 11) asphalt felt for compliance with Florida Building Code 2004 and
2007 (HVHZ) Testing Application Standard (TAS) 110-2000: TESTING REQUIREMENTS
FOR PHYSICAL PROPERTIES OF ROOF MEMBRANES, INSULATION, COATINGS, AND
OTHER ROOFING COMPONENTS, Section 2.2: Roofing Components within asphalt built-up
and modified bitumen roof assemblies, and. Florida Building Code 2004 and 2007; Sections
1507.2.3, 1507.3:3; 1507..5.3, and 1507.7.3: Underlayment using ASTM D 226-97a and
ASTM D 226-06: Standard Specification forA. sphalt Saturated Organic Felt Used in Roofing
and Waterproofing,- Type II.
Test Methods: The test methods used included those. found in' F13C TAS 116-2000: TESTING
REQUIREMENTS FOR PHYSICAL PROPERTIES OF ROOF MEMBRANES, lIUSULATION,
COATINGS, AND OTHER ROOFING COMPONENTS and including: ASTM D 226: Standard
Specification forAsphalt-Saturated Organic Felt Used in Roofing and Waterproofing; ASTM D
146:. Standard Test Methods for Sampling and. Testing Bitumen -Saturated Felts and Woven
Fabrics for Roofing and Waterproofing; ASTM D 727: Test Method for Kerosine Number of
Roofing and Flooring Felt by the Vacuum Method.
Sample - The sample received from Tamko Building Materials on December 31, 2008 was a full factory
Description:'- labeled roll of felt.
TAP-215412-01 PRI Acdeditations• IAS-ES TL-189; State of Florida. TST5878; Metro -Dade 06-111602; CRRC
The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusfve.use of stated
client. No reproduction orfacsimile in anyform can be made without the client's permission. This report shall not be reproduced except in
full without the written approval of this laboratory. PRI Construction Materials Technologies, LLC. assumes no responsibility nor makes a
performance or warranty statement for this material or products and processes containing this material in connection with this report
PRI Construction Matey & Tedmftgies. LLC. 6408 Badger Drive Tampa. FL 33610 Tel: 813.6215n7 Fac 8t3-621-M email mAdalstasting.@;dic rem W&SM htWMiwx,.pricmtmm
Tamko Building Products
Laboratory Test Report for No. 30 ASTM Saturated Felt
PRI08122
Page 2 of 2
Results of Testina:
Property
• 211
26 Type
Result
..
. Requirement
5- Materials and Manufacture
D 226
Pass Free of Lumps or particles or foreign
substances
Physical Requirements
Table6.
6.1
Average breaking:strength, Ibf/in
Dt46
= -
MD
69
40 min
CMD
28
20 min
Pliability @ 770F
D 146
Pass
No cracking
Loss on heating @ 221 °F, %
D 146
2.7
4 max
Width of roll, in
D 146
36.0
36 t 0;7°favor as?axeed'
Area of roll, ft.2
D 146
216.7
2 t6 oc432 rrttQrasgree
Moisture at point of manufacture, %
D 146
3.2
Net mass of saturated felt, lb/100 ff
D 146
28.0
26;mirk_
t�
Mass of saturant, Ib/100 fe
D 146
17.4
Mass of desaturated felt, Ib/100 ff
D 146
10.8
x}tinlr ��'
Ash, %
D 146
4.5..�0�
Saturation, %
D 146-
6.2 Unroll @ 50 and 140°F
D 226
6.3 Perforated felt
D 226
7 Workmanship,. Finish,
D 226
Pass=
.affi
Appearance
.
Note 1: Or as agreed upon by purchaser and -seller.
Statement of Compliance:
This product complies with all of the requirements of Florida Building Code 2004 and 2007. (HVHZ).Testing
Application Standard (TAS) 110-2000: TESTING REQUIREMENTS FOR PHYSICAL PROPERTIES 01=
ROOF MEMBRANES, INSULATION, COATINGS, AND OTHER ROOFING COMPONENTS, Section 2.2:
Roofing Components within asphalt built-up and modifiedbitumen roof assemblies,.and.Flodda Building Code
2004 and 2007; Sections 1507.2.3, _1507.3.3, 1507.5.3, and 1507.7.3: Underlayment using ASTM D 226-97a:
Standard Specification forAsphalt-SaturatedOrganic Felt Used in Roofing and Waterproofing, Typell. The
product also complies with all of the requirements of-ASTM D 226-06: Standard Specification forAsphalt-
Saturated Organic Felt Used in Roofing and Waterproofing, Type 11. Limitations: None.
Signed -
Donald C. P olio
President
Date:
Signed: C
Duc T. Ngu _1
Florida Registered Profq
onal Engineer
P. E.:Number: 65034
TAP-215-02-01 PRI Accreditation: IAS-ES TLA M. State of Florida TST5878; Metro -Dade. 06-1116.02; CRRC
The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive, use of stated
client: No reproduction orfacsiinile in anyform can be made without the client`s permission. This report shall not be reproduced except in
full without the written approval of this laboratory_ PRI Construction Materials Technologies. LLC. assumes no responsibility nor makes a
performance or warranty statement for this material or products and processes containing. this material in connection with this report
PRI Comtruciiw Materials Tectmologles, LLC. 6408 Badger Drive Tampa FL 33610 TeL 813-621ZTR F= 813-621-5W e4n80 materialstestimg@Prkntcom WebSitrr h JNmw.pricmtcom
TAMK06 NO•30 UL PRODUCT DATA
Asphalt Saturated Organic Felt W
Manufactured in Joplin, MO, Frederick, MD,
and Green Cove Springs, FL
TAMKO° NO. 30 UL SATURATED FELT
features a tough TAMKO organic felt that is
saturated with asphalt.
Accepted for use as an underlayment felt to be applied
over the roof deck prior to the installation of TAMKO
asphalt shingles.
smn�[aRannv� --
U.L. Built -Up Type 30 Label
ASTM D 226, Type II
Roll Dimensions 72' X 36" - -
Coverage per roll 2 Squares
Laying Lines 2", 4", 17"
'All values stated as nominal
THIS PRODUCT IS SOLD "AS IS" WITHOUT WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
Visit our Web Site at tamko.com
AUiION: This product contains wood dust N.bcd dust has been dassfiad as a `imcrW human cardragen by the Irrational Agency for Researc
n Cancer ([ARC) and the National Toxicology Program This product also confairs owdized asphalt Occupational e)ipostres to oxidized asphalt and B
missiersduringreofmghave been classified by[ARCasa'probab[ehurnaicar=rogen".Ondzedaspha[tdmcatwsPelycyrlicAr tabcHydomrbor
weofvvli havebeen dassiliiedbyIARCasknownorprobablehumancaranogarsThe physical nature ofth"sproduct mayhelprarutany mfhalabon<
lerrral hazard duainga� and(crrarewal. Havaver, physcal torcm&ich as sawwS 4mdrx3 ordffz9 ding daTc[ton vvakard heating orburn6u
my haeasethe inhalation or dermal aposure hazard ofths produd.Takeprecathorsto prevent tithing and mrtactvrith skm
Central District
220 West 4th St.
Joplin, MO
64801
800-641-4691
Northeast District
4500 Tamko Dr.
Frederick, MD
21701
800-368-2055
BUILDING PRODUCTS
Southeast District
2300 35th St.
Tuscaloosa, AL
35401
800-228-2656
Southwest District
7910 S. Central Exp.
Dallas, TX
75216
800-443-1834
TAMKO Logo, Roofer toga and TAMKO9
Western District
5300 East 43rd Ave.
Denver, CO
80216
800-530-8868
are registered trademarks of
TAMKOa Building Products, Inc.
Information included in this
product data sheet was current at time of printing. To obtain a copy of
the
most current version of this
product data sheet, visit us online at tamko.com or call us at 800-641-4691.
Rev. 0512012
FW?APA,0RPAFlTM3NT OF
�1
Business ♦ ♦ 9 Y. • R', 4
gdaDepartments BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Seartirsines
Professi IOUSER: Product Approval
Regulation
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
FL10674-R9
Revision
2010
Approved
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscorning.com
Greg Keeler
greg.keeler@owenscorning.com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscornig.com
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
idl Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
PE-59166
UL LLC
07/17/2017
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL10674 R9 COI 2014 01 COI Nieminen.pdf
Standard
ASTM D3161, Class F
ASTM D3462
ASTM D7158, Class H
Year
2006
2007
2007
TRINITY
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
ER® OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
Evaluation Report 037940.02.12-114
FL10674-R9
Date of Issuance: 02/06/2012
Revision 4: 03/04/2014
SCOPE:
This Evaluation Report is issued under Rule 914-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED. COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation
Report relative to Updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrihityJERD Evaluated" may
be displayed in advertising, literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P.E. on 03/04/2014
This does not serve as an electronically signed
document Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named dient
CERTIFICATION of INDEPENDENCE:
1. TriniMIERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products It evaluates.
2: TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nleminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
TFUNIIY ERD
ROOFING SysTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the Florida Building Code and Florida Building
Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Propertv Standard
Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462
2007
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F
2006
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H
2O07
3. REFERENCES:
Entity Examination Reference
Date
UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3
02/15/2007
UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453
05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263
04/18/2006
UL LLC (TST9628) Wind Resistance 11CA34308
02/18/2012
UL LLC (TST9628) Physicals & Wind Resistance 4786093137
02/01/2014
UL LLC (TST9628) Wind Resistance 4786126532
02/10/2014
UL LLC (TST9628) Physical Properties Classification letter
02/13/2014
Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs
Various
UL LLC (QUA9625) Quality Control Service Confirmation R2453 Exp. 09/26/2014
4. PRODUCT DESCRIPTION:.
4.1 Asphalt Shingles:
4.1.1 Classic® and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 DevonshireTm are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration®, TruDefinition® Duration®, Duration® Premium Cool,
TruDefinition® Duration®
Designer Color Collection, TruDefinition® OakridgeO, OakridgeO and WeatherGuardO HP are
fiberglass reinforced, laminated asphalt roof shingles.
4.2 Berkshire°) Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant,
WeatherGuardO HP Hip
& Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeTm
Hip & Ridge Shingles are
fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt
roof shingles.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4
Certitieate of Authorization &9503 FL10674-R9
Revision 4: 03/04/2014
Page 2 of 7
i
J TRINITY ERD
5.3.1 All Owens Coming shingles noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating
the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (VW, = 194 mph).
Refer to Section 6 for installation requirements to meet this wind rating.
5.3.2 All Owens Coming hip & ridge shingles and Starter Strip Plus noted herein are Classified in
accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all wind zones up to Vad = 150 mph (VWt = 194 mph). Refer
to Section 6 for installation requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less.. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to -each shingle.
5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Coming and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4
or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
or R905.2, with the following exceptions:
➢ Berkshire® shingles require minimum five (5) nails per shingle.
➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle.
➢ Devonshire TM shingles require minimum six (6) nails per shingle.
➢ Starter Strip Plus requires minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4
Certificate of Authorization #9503 FL10674-119
Revision 4: 03/04/2014
Page 3 of 7
6.2.5 Minimum Nailing — Classic@ & Supreme:
Normal Mansard or Area pare
Mfind Areas High Wind desvanes y
Area paw vientos normales Anus vientos f cartes
t-tt• (A) tt,t• rt• 2-i (B 2• t.
6°Exposure
Ezposiaibn
6.2.6 Minimum Nailing — BerkshireO:
Seatard strip
!a ttra de seW r
sit, 9 Vf I 9'Yf I 8 w,
t
6.2.7 Minimum Nailing — Devonshire TM:
-,I TPJNITY I ERD
Normal Mansard or Area paw
Wind Areas High Wind desvames y
Area paw vientos normales Areas vientos foertes
t2 t21 T r 2', (B 2- t-
5 51 ' Exposure
Exposleibn
Sealant strip
to Lira de seikrbr
•� Otip—f• 9.4 be- *0
8Yt' B.Yt 8'�
r t"
r r� A-
P4Wmk Footing cement
Cem Wdeteehadeaslab
Nails
r e r
13-W •Y
Ten 1" Spots of Asphalt Roof Cement
6.2.8 Minimum Nailing — Duration@, TruDefinition(g) Duration, Duration@ Premium Cool &
TruDefinition° Duration° Designer Color Collection:
6 Nai bnsatd and stied supe fasten 'between SuaNai
Main areaandlep dMud.
F_S Wwm — 9bnsa& opadsatrs
do SdaVas arAlasRpdaeerned
•. • • SaeMal®y6pxb
stpaiadrlraafe.
i bnnrg�g;Sur&P
arawuth. attaNiaia
Awade r \ dt
su rblo 7r ^ .dr• ` S emiP
LiE
SW Exposure Naas SW Exposue
S%polg. de exposkide Cla►6s Y%pudg. de uMsloldn
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-114
Certificate of Authorization #9503 FL10674-119
Revision 4: 03/04/2014
Page 4of7
6.2.9 Minimum Nailing — TruDefinitionO Oakridge0, OakridgeO:
4 Nall Pattom
Esquema con 4 davos
5W EXPM!
apos1d 55/8pidg 6Nags Erposf 55/8prdg
6.2.10 Minimum Nailing — WeatherGuard® HP:
6.3 Hip & Ridge Shingles:
\,I I RINI7Y ERD
6 Nall PaK¢m
Esquema can 6 davos
rr
55Ar gpgsme �� 55%"Egxmje
brposidou.debWBpdg Expasiadade &5/Sprdg
11/bb IrErd
R�7lm� N� IJb
6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant,
WeatherGuardO HP Hip and Ridge Shingles and Pro Edge Hip & Ridge Shingles shall comply
with the manufacturer's current published instructions, using four (4) nails per shingle.
Installation of DuraRidgeT"' Hip & Ridge Shingles shall comply with the manufacturer's current
published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing
for wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4
Certificate of Authorization #9503 FL10674-119
Revision 4: 03/04/2014
Page 5 of 7
6.3.3
6.3.4
6.3.5
Minimum Nailing - Berkshire@ Hip & Ridge and High Ridge:
Fig. 1 q
<— Pmraltmwste
WeWun A
Nags A
A I I
I I
A I I
4 I I
1 1 1 I
A i i t 1
�e
`.t TjtlNfjYIERD
FIg.2
Top View
_SiUeView.
Naffs .Nails
7__ TOP Lanila[ed r 7.
4-
Piew
Y
1
1
I
4
ml
SI
1
ml,
VI
1
I
I
1
Minimum Nailing - Hip & Ridge with Sealant:
earn Fig., 2 : High W kW Fas elnittg Fatten
�� Nailsj
rim Shingle
Discard 2,.�,�
brae 7•' ,1,.
Se�lairrt =�
..Strip 12"
' Fas466 i rg: 5 �}s S ,• Expasu
Dina
12 ,1..
Minimum Nailing - WeatherGuard@ HP Hip and Ridge:
Fig. A 9 1?
Pt4�raEhlg raw
<- Dllat3bn
A
Halls` 4 4
" I I
A I I
I
I I
AA I I I I
Eiposure
Fig. C Hip & Ridge. Shingle Fastening
Topvlm
Naps Nails
T'
7 2-
j. �.
G. Elposure
I 17'
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4
Certificate of Authorization #9503 FL10674-119
Revision 4: 03/04/2014
Page 6 of 7
6.3.6 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prevailing
Wind Direction Sealant Strip
6' Exposure
Fasten Th'
Cover Exposed
Fasteners with
Roof Cement
F)o
\,JTPJNITYI ERD
Standard
Fastening
�17._►
Pattern
I`
12'
Sealant
I
h
6" Exposure
6.3.7 Minimum Nailing — DuraRidgeTm Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to
Owens Corning published installation instructions for their minimum requirements.
— D�cti nddornimi adjYmt
Di�C=dalvimto prodornimnto
Naib —� n
�IaIA 1 1
C1aas�
4
I I 1 1
It
P
7. LABELING:
Top View
Vac en plan
I�. Vista superior 1"IH
T �
S Goo
OVmm Coning Sumtlad•' Cf.o
u i
i
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 ; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4
Certificate of Authorization #9503 FL10674-119
Revision 4: 03/04/2014
Page 7 of 7