Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSi ALL APP A I O S B COMPLETED FOR APPLICATION TO BE ACCEPTED Date: SCANNED Permit Number: BY St. Lucie County Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential �Z/ PERMIT APPLICATION FOR: To Select from dropbox, click arrow at the end of line PROPOSED IMPROVEMENT,LOCATION: Address: 110 Beach Ave, Port St Lucie, FL 34952-1320 Legal Description: RIVER PARK -UNIT 3-BLOCK 26 LOT 1 (MAP 34/22S) (OR 1029-2161 THRU 2165: 1042-2133) Property Tax ID #: 3419-515-0158-000-8 Site Plan Name: Project Name: 110 BEACH-REROOF Setbacks Front Back: Right Side: Left Side: Lot No. 1 Block No. 26 DETAILED DESCRIPTION OF.WORK: RE -ROOF: Tear -off existing roof coverings and replace yvith n '2.3 00 CONSTRUCTION INFORMATION. Acid itiona I work to be nertormed under this permit —check a apply: 0HVAC Gas Tank Gas Piping Shutters a Windows/Doors Electric 0 Plumbing Sprinklers Generator _ Roof Total Sq. Ft of Construction: 0. _'4 0 �2 c . Ft. of Firs !F o r: Cost of Construction: $ � , �� Utilities: Sewer _ Septic Building Height: 01NN;ER/LESSEE: : CONTRACTOR: Na_e �i v�� Name: John F Durham Company: Durham Brothers, Inc. Address: 110 beac6 Ave City.. Port St Lucie State: FL Address: 15897 62nd Place N Zip Code: 34952-1320 Fax: City: Loxahatchee State: FL hone N � . — -7 Zip Code: 33470 Fax: (561) 491-1997 (� /�� �%4 -� ��� U'lG • C� Phone No. (561) 315-1835 Fill-in fee simple Title Holder on next page (if different E-Mail: johnfdurham@msn.com from the Owner listed above) State or County License: CCC 1326757 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL-CONSTRU.CTION;LIEN' LAW: FORMATION DESIGNER/ENGINEER: — Not Applica a MORTGAGE COMPANY: Not App ' able Name: — Name: Address: Address: City: State: City: State: Zip: Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: _Not Applicable Name: Name: Address: City: Address: City: Zip: Phone: Zip: Pone: I certify t t no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that 1 will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording vour Notice of Commencement. *� EZ4� y Signature of caner/ Agent/ Lessee STATE OF FLORIDA COUNTY OF -55^-u The forping instrument was acknowledged before me this I 2S day of 20 14 by of Contractor/License Holder STATE OF FLORIDA COUNTY OF The forgoing instrument was acknowledged before me this I " day of Se--v+ , 20_.IA by (Name of person acknowledging) (Name of person acknowledging) Notary Public- State of Florida ) Personally Known OR Produced Identification Type of Identification Produced, ,QZ, s Loco- ip— ture of Notary Public- State of Florida ) Personally Known OR Produced Identification Type of Identification Produced Commission No. ® (Seal) Commission No. _L al c([ yo F,;h al) Not9ry a e U oe �bty Corp eyallos a ofFloriq Revised 07/15/2014Fa ° miss. a 070 EF ► nr .__. KEITH NEWMAN �4/?016 219140 +. �''• 'o� MY Com State of Flo ida REVIEWS FRON NG Com �F�io i OEeRIVOSIy 17 LANS VEGETATION SEA TURTLE MANGR COUNT ii`�`�IW7175 VIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 3992607 OR BOOK 366 _ rAGE 2032, Recorded 09/08/2014 at 10:' ',AM Doc Tax: $322.00 This instrument was prepared incident to the issuance of a title insurance contract, and is to be returned to: Sharon A. Evans, an employee of Liberty Title Company of America, Inc., I W SE Port St. Lucie Blvd Port St. Lucie, Florida 34952 File No. SL-14-0227 Co orate Warranty Deed is In made tern 5,2 . ., be en Br o on 0rp0 'on ' ting der th aws a State of Flori se post offic ad ss i 503 W Holly b e, Palm ity, Ind 34 0, cantor, d ely alle a married woma , wh a post office is 470 Carla Court Port t. Luc* , Flo ida 34986, ee, itnesseth, that the said rant r, for and in consi erg of th sum of Ten and 100 Dollars ( 0.00 , to it in hand paid by the aid rantee, the receipt whe of t hereby ackno edg , has to and sold to the s id ranee forever, the follo ' de 'bed land, si d ing in the C ty St. Luci , S to of Florida to wit: Lot , lock 26, RIVE ARK U 3, accordin o the PI t thereof as rec rded in Plat Book 10 g f the Public Re Lucie Caun , SUBJECT TO covenants, restrictions, easements of record and taxes for the current year. Parcel Identification Number: 3420-515-0158-000/8 And the said Grantor does hereby fully warrant the title to said land, and will defend the same against the lawful claims of all persons whomsoever. In Witness Whereof, the said Grantor has caused this instrument to be executed in its name by its duly authorized officer and caused its corporate seal to be affixed the day and year first above written. State of Vermont County of Bennington J The foregoing instrument was acknowledged before me this Y:�: day of September, 2014, by William R. Neuhaus, the Vice -President of Broadstone, Inc., a corporation existing under the laws of the State of Florida, on behalf of the corporation, who is/are either personally known to me or who has produced identification of sufficient character so as to identify said individual with reasonable certainty; and who did not take an oath.. otary Pu6llc. State of Vermonk atLarRe ;C rur4u 10 File Copy Mh4M1 r IZ_�n -c Cry e MIANII-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/nera Tamko Building Products, Inc. 220 West Fourth Street, Joplin, MO 64802 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TAMKO Roof Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any . section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11-0223.10 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 11-1228.01 Expiration Date: 03/21/17 Approval Date: 04/26/12 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category Roofing Sub-Cateeory: Asphalt Shingles Materials Laminate Deck Tyne: Wood SCOPE This approves Tamko Heritage 30, Heritage, Heritage 50, Heritage Premium and Heritage Woodgate Asphalt Shingles, manufactured by Tamko Building Products, Inc. as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Specifications Heritage 30 and Heritage 12" x 363/$" TAS 110 Heritage 50 and Heritage 12" x 36" TAS 110 Premium Heritage Woodgate 12" x 363/8" TAS 110 MANUFACTURING LOCATION 1. Frederick, MD EVIDENCE SUBMITTED Test Agency Underwriters Laboratories, Inc. PRI Asphalt Technologies, Inc. Test Identifier TAS 107 TAS 107 TAS 107 ASTM D3462 ASTM D3462 ASTM D 3462 TAS 107 TAS 100 TAS 100 TAS 100 TAS 100 TAS 100 TAS 100 TAS 100 Product Description A heavy weight, dimensional asphalt shingle. A heavy weight, dimensional asphalt shingle. A heavy weight dimensional asphalt shingle. Test Name/Report Date OINK409172 12/04/01 04NK24366 02/24/05 04NK24366 11 /12/04 R2919 02/25/02 04NK24366 11 /05/04 R2919 06/12/03 03CA08442 06/12/03 TAP-052-02-01 11/28/01 TAP-053-02-01 11 /29/01 TAP-054-02-01 11 /29/01 TAP-117-02-01 11 / 11 /04 TAP-116-02-01 11 / 11 /04 TAP-115-02-01 11 / 11 /04 TAP-066-02-01 01 /09/03 NOA No.: 11-1228.01 Expiration Date: 03/21/17 Approval Date: 04/26/12 Page 2 of 6 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail 'B', attached. LABELING 1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved". MIAMI•DADE COUNTY ��Fjuuaorjqbj BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 11-1228.01 Expiration Date: 03/21/17 Approval Date: 04/26/12 Page 3 of 6 DETAIL A HERITAGE 30, HERITAGE, AND HERITAGE WOODGATE ISE 1ST COURSE HERITAGE 50 AND HERITAGE PREMIUM JRSE 1ST COURSE NOA No.: 11-1228.01 Expiration Date: 03/21/17 Approval Date: 04/26/12 Page 4 of 6 SEALANT DETAIL B HERITAGE 30 AND HERITAGE 1Z' x 3&3V LAMINATED SHINGLE Al dimensions are in indm& 37 FRONT BACK HERITAGE 30 AND HERITAGE (OPTIONAL SEALANT PLACEMENT) FRONT SEALANT -\ -F► NOA No.: 11-1228.01 MIAMI•DADE COUNTY Expiration Date: 03/21/17 Approval Date: 04/26/12 Page 5 of 6 5 1/2 5 1/2 DETAIL B (CONT.) HERITAGE 50 AND HERITAGE PREMIUM 12" x 36" LAMINATED SHINGLE_ All dimensions are in inches. 36 9 1 /2 3 9 3 9 1 /2 �—{I HERITAGE WOODGATE 12" x 36-3/8" LAMINATED SHINGLE All dimensions are in inches. 36 1h-- 9 1/2 3 9-3/8 3 9 1/2 -I END OF THIS ACCEPTANCE 12 5 Exposure 12 5 Exposure NOA No.: 11-1228.01 Expiration Date: 03/21/17 Approval Date: 04/26/12 Page 6 of 6 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Poly lass USA, Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Modified Bitumen Roof System Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 12-0710.04 and consists of pages 1 through 32. The submitted documentation was reviewed by Alex Tigera. NOA No.: 13-0416.05 Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 1 of 32 ROOFING ASSEMBLY APPROVAL Category Roofing Sub -Category: Modified Bitumen Materials SBS/APP/TPO Deck Type: Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Polyflex 32' 10" x 3' 3-3/8" ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polyflex G 32' 10" x 3' 3-3/8" ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface. Polyflex G FR 32' 10" x 3' 3-3/8" ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface and fire retardant chemistry. Polybond 32' 10" x 3' 3-3/8" ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polybond G 32' 10" x 3' 3-3/8" ASTM D 6222 Torch applied, polyester reinforced, APP modified Type I bitumen membrane with a burn off polyethylene back face and a granule top surface. Elastoflex S6 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a polyethylene or sanded top surface. Elastoflex S6 G 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a granule top surface. Elastoflex S6 G FR 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied; polyester reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a granule top surface and fire retardant chemistry. Elastoshield TSG 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a granule top surface. NOA No.: 13-0416.05 rt[AMi•oApe couNrr Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 2 of 32 r � _ TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1< Test Product Product Dimensions Specification Description Elastoshield TSG FR 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a granule top surface and fire retardant chemistry. Elastoflex V 32' 10" x 3' 3-3/8" ASTM D 6163 Torch, hot asphalt or cold adhesive applied, fiberglass reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a sanded top surface. Also available in a thicker version listed as Elastoflex V 2.5. Polyfresko Mop 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a granule top surface. Polyfresko Mop FR 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a granule top surface and fire retardant chemistry. Polyfresko Torch 32' 10" x 3' 3-3/8" ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface. Polyfresko Torch FR 32' 10" x 3' 3-3/8" ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface and fire retardant chemistry. Elastobase 65' 2" x 3' 3-3/8" ASTM D 6163 SBS modified asphalt coated fiberglass reinforced base Type I sheet. Elastobase P Cold Process Adhesive PG100 Asphalt Primer PG350 Mod Bit Adhesive PG400 Plastic Roof Cement PG425 Wet/Dry Roof Cement 65' 2" x 3' 3-3/8" ASTM D 6164 SBS modified asphalt coated polyester reinforced base sheet. 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal, tube or 17 oz. spray can 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. or tube ASTM D3019 A fibered cold process adhesive for use with roll or Type III BUR roofing. ASTM D41 A penetrating solution of solvent and a blend of selected asphalts used to promote adhesion. ASTM D3019 A fibered rubberized adhesive designed for use. with Type III modified bitumen membranes. ASTM D4586 A thick, fibered, rubberized flashing cement for use in ASTM D3409 dry or damp conditions. ASTM D4586 A thick, fibered, rubberized flashing cement for use in ASTM D3409 dry or damp conditions. NOA No.: 13-0416.05 MIAMI•DADe COUNT Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 3 of 32 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description PG450 Flashing 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement. Cement tube PG500 MB Flashing 1, 3, 5, 50, 55 gal. or ASTM D4586 Cement tube Polyplus 35 Premium 1, 3,' 5, 50, 55 gal. or ASTM D3019 Mod Bit Adhesive tube Type III Polyplus 45 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 Flashing Cement tube A thick, fibered, rubberized flashing cement for use with modified bitumen membranes. A fibered rubberized adhesive designed for use with modified bitumen membranes. A thick, fibered, rubberized flashing cement. Polyplus 50 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement for use MB Flashing Cement tube with modified bitumen membranes. Polyplus 55 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A mastic compound for use as a roof flashing adhesive. Modified Flashing tube Cement APPROVED INSULATIONS: Product Name POLYTHERM POLYTHERM Composite ACFoam II, ACFoam III High Density Wood Fiberboard Dens -Deck or Dens Deck Prime FescoBoard H-Shield ENRGY 3 Multi-Max-3, Multi -Max FA-3 SECUROCK Gypsum -Fiber Board TABLE 2 Product Description Polyisocyanurate foam insulation PolyIso/perlite composite insulation. Polyisocyanurate foam insulation Wood fiber insulation board Gypsum insulation board Rigid perlite roof insulation board. Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Fiber reinforced coverboard Manufacturer (With Current NOA) Polyglass USA, Inc. Polyglass USA, Inc. Atlas Roofing Corporation Generic Georgia Pacific Gypsum LLC Johns Manville Corp. Hunter Panels, LLC Johns Manville Corp. Rmax Operating, LLC USG Corporation NOA No.: 13-0416.05 Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 4 of 32 APPROVED FASTENERS: TABLE 3 Fastener Product Product Number Name Descriution 1. Dekfast 12, Dekfast 14 Insulation fastener for wood, steel & Dekfast 15 HS and concrete decks 2. Dekfast Galvalume Galvalume hex stress plate. Steel Hex Plate 3. Dekfast Dekflat Round Polypropylene locking plate. Plastic Lock Plate 4. 412 Standard Roofgrip Insulation and membrane fastener & #14 Roofgrip 5. Flat Bottom Metal Galvalume AZ50 stress plate Plate 6. OMG Plastic Plate Polyethylene stress plate 7. Trufast 414 HD Insulation fastener for steel and wood Fastener decks 8. Trufast 3" Metal Galvalume steel plate Insulation Plate Manufacturer Dimensions (With Current NOA) SFS Intec, Inc. 2 7/8" x SFS Intec, Inc. 3 '/4" 3" x 3 '/4" SFS Intec, Inc. Various OMG, Inc. 3" square OMG, Inc. 3.2" round OMG, Inc. Altenloh, Brinck & Co. U.S., Inc. 3" round Altenloh, Brinck & Co. U.S., Inc. NOA No.: 13-0416.05 Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 5 of 32 APPROVED SURFACING: TABLE 4 Number Product Product Application Specification Manufacturer Name Description Rate 1. PG200 Non-Fibered A non fibered asphaltic coating 11/2-2 gal/sq TAS 140 Polyglass USA, Roof Coating used to add life and rejuvenate Inc existing BUR roofing substrates. 2. PG300 Fibered Roof An asphalt cutback fibered roof 1'/z-2 gal/sq ASTM D4479 Polyglass USA, Coating coating. May be applied by Inc. brush or spray equipment to rejuvenate aged BUR 3. PG600 Non-Fibered Non-fibered aluminum roof '/2-1 gal/sq ASTM D2824 Polyglass USA, Aluminum Roof coating. Type I Inc. Coating 4. PG650 Fibered Fibered aluminum roof coating. 11/2-2 gaUsq ASTM D2824 Polyglass USA, Aluminum Roof Type III Inc. Coating 5. PG700 White A premium white elastomeric 1-1'h gal/sq ASTM D6083 Polyglass USA, Elastomeric Roof acrylic based roof coating Inc. Coating (water -based). A polyester fabric may be used for reinforcement with this coating. 6. PG800 Non-Fibered An asphalt based, non-fibered 3 gal/sq in two ASTM D1227 Polyglass USA, Asphalt Emulsion Roof clay emulsion coats Inc. Coating 7. PG850 Fibered Asphalt An asphalt base, fibered clay 3 gaUsq in two ASTM D1227 Polyglass USA, Emulsion Roof Coating emulsion coats Inc. 8. Polyplus 65 Premium Fibered aluminum roof coating. 11/2-2 gal/sq ASTM D2824 Polyglass USA, Fibered Aluminum Type III Inc. Roof Coating 9. Polyplus 60 Premium Non-fibered aluminum roof %2-1 gal/sq ASTM D2824 Polyglass USA, Non-Fibered coating. Type I Inc. Aluminum Roof Coating 10. Polybrite 70 White A premium white elastomeric 1-1'/Z gal/sq ASTM D6083 Polyglass USA, Elastomeric Roof acrylic based roof coating Inc. Coating (water -based). A polyester fabric may be used for reinforcement with this coating. 11. Gravel To be installed in a flood coat 400 lbs/sq N/A Generic of approved asphalt at 60 lbs/sq 12. Slag To be installed in a flood coat 3001bs/sq N/A Generic of approved asphalt at 60 lbs/sq NOA No.: 13-0416.05 Miar�i•n�e couNrir Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 6 of 32 EVIDENCE SUBMITTED: Test Agency Test Name/Report Report No. Date Factory Mutual Research 4470 J.I.2W7A7.AM 08.04.94 Corporation 4470 J.I.3001334 02.15.00 4470 J.I.3000857 01.12.00 4470 J.I.3004091 01.12.00 Underwriters Laboratory TAS 114 OONK20869 06.08.00 Trintiy ERD TAS 114 #11751.05.03 05.30.03 TAS 114 11757.12.00-1 12.01.00 TAS 114 11757.04.01-1 04.27.01 TAS 114 #11758.08.03 08.11.03 TAS 114 01738.02.07 02.05.07 TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07 ASTM D 6164 / D 6222 P10490.10.08-R1 10.03.08 ASTM D6222 P37590.07.13-2 07.01.13 ASTM D6222 P37590.03.13-5-RI 07.01.13 ASTM D6509 P37590.03.13-1-R1 06.26.13 ASTM D6164 P37590.03.13-3A 03.06.13 ASTM D6164 P37590.07.13-1 07.02.13 ASTM D6163 P37590.03.13-2-R1 07.01.13 PRI Asphalt Technologies ASTM D6222 PUSA-062-02-01 12.04.07 ASTM D6163 PUSA-064-02-02 02.27.08 NOA No.: • 13-0416.05 MIAMI•DAD; COUNTY Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 7 of 32 Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank. System Type E(4): Base sheet is mechanically attached to roof deck. All General and System Limitations apply. Base Sheet: One ply of Elastobase or Elastobase P fastened to the deck as described below: Fastening: 11 ga. Annular ring shanked nails and 1-5/8" tin -caps 6" o.c. in 4" lap and 6" o.c. in four equally spaced staggered rows. Tin -caps are primed with PG100 primer. Ply Sheet: (Optional) One or more plies of Elastobase, Elastoflex S6, Elastoflex V, Elastoflex V 2.5 or one or more plies of Type IV or VI ply sheet adhered in full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. Membrane: One ply of Polyflex, Polyflex G, Polyflex G FR, Polyfresko Torch, Polyfresko Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6 G, Elastoflex S6 G Fk, Polyfresko Mop, Polyfresko Mop FR, Elastoshield TSG or Elastoshield TSG FR torch or hot asphalt applied. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -112.5 psf; (See General Limitation 47) NOA No.: 13-0416.05 Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 31 of 32 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq., or mechanically attached using the fastening pattern of the top layer. 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) END OF THIS ACCEPTANCE NOA No.: 13-0416.05 MIAMi•oADe COUNTY Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 32 of 32 A & F Engineering, Inc. Lieerfsed l�ngi�eers P.E. No. 53842 3340 Fairlane Farms Road, #7 Wellington, FL 33414 Rhone No. 561 790 3116 Fax 561 300 2148 October 2, 2014 2014 St. Lucie County Building Division 2300 Virginia Ave Ft Pierce, FL 34952 RE:110 Beach Ave Port St Lucce FL Field=47 PSF Perimeter=-112PSF Corner = -122 Sheet with 36" Net length = 33.33' Lap = 4" Ring shank mat design pressure 45PST Side lap : 1.2 fasteners / ft x 33.33 ft/row x 2row / sq = 90 fast / sq 130 fast / sq 100 ft 2/120 fast /sq = 0.77 fast/ft2 Fs= fyx144/ p x RS = (37.5) x (144) / (P) x 36 / 3=12) P=(-47,-83, -122) Z1= 9" Z2=5" Z3=4" Should you have any questions concerning this matter, please contact me at (561) 790 3116 Sincerely David C. Forkey P.E. 53 842 Planning & Development Services j .� Building & Code Regulation Division ® 2300 Virginia Avenue s Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # SL C / 1/D 9 03 i / I, licensed as a(n) ontractor* Engineer/Architect (Please print name & circle license type) *FS468 Bu Inspector General Building, Residential o®Roofingontractor or any individual certified under 468 F.S. to make such an inspection. On or about a2 / I did personally inspect the roof deck nailing (Da e) work at: //0 s� A (Job site address) Based upon that examination I have determined the installation was done according to the current edition of the Florida Existing Building Code Section 611 or the product approval submitted (whichever is most stri t). Signature and Seal STATE OF FLORIDA COUNTY OF�k.\•." License # Sworn to and subscribed before me this a day ofyLJ�pQ�.o n 201q, byWho is personally known to me or who has produced DUS0",}40,'Zlr'303• C1 as identification. Notary Public, State ofFlorida ,�a;iir LASHAHNAINGRAM tP ;,r ,_ MY COMMISSION # EE 050553 Signature of Notary: EXPIRES: December 20, 2014 Commission Number: kF-•OSo5Y'3 (Sea y q;; `.�`' Bonded Thru Notary Public Underwriters En 01/19/2011