Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE ONLY SECTION TOWNSHIP RANGE MAP NO. ZONING LAND USE LOT CVG % TAZ NO. FLOOD ZONE FIRM MAP # In FLR ELV MAX HGT CONST TYPE OCCUP TYPE MAX OCCUP # OF FLRS WATER SEWER SPRINKLERS STORMWATER LOT OF REC Before 1/1990 LOT OF REC After 1/1990 LOT SPLIT REQUIRED LOT SPLIT APPROVED REPORT CODE ® 1 HABITABLE AREA (RADON) RADON FEE PERMIT FEE LIBRARY IMPACT FEE PUBLIC BLD IMPACT FEE CORRECTION PUBIC BLD IMPACT FEE GENERAL PARKS IMPACT . FEE SCHOOL IMPACT FEE ROAD IMPACT FEE CREDIT Y N LAW ENF IMPACT FEE FIRF/EMS IMPACT FEE DRIVEWAY REQUIRED Y N DRIVEWAY FEE ADMINISTRATIVE VARIANCE FEE SPECIFY SUBS REQUIRED. MECHANIC ROOF ELECTRIC GAS PLUMBING NON -CONFORMING LOT OF RECORD FEES MISCELLANEOUS FEES DATE SENT TO ADDRESSING: REVIEWS FRONT COUNTER ZONING REVIEW SUPERVISOR REVIEW PLANS VEGETATION REVIEW SEA TURTLE REVIEW MANGROVE REVIEW RCEEIVED i �REVIEW ! Jz / DATE) COMPLETED ' INITIALS u PLAN REVIEW FEE: 'RECEIPT NO.: PERMIT NOMBER: CONCURRENCYRECEIPT NO.: CERT. CAP. NO.: ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED may. . { _ St. Lucie County Building and Zoning " 2300 Virginia Avenue Ft. Pierce, FL 34982-5652� �b SCANNED772-462-1553 BY St. Lucie County APPLICATION for BUILDING PERMIT CERTIFICATE of CAPACITY/ZONING COMPLIANCE PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 2. PROJECT NAME: Span o u n i s h Lakes i l a gTTge 1 PLAN NAME: 3. PROPERTYTAXID#: aQ -1 l �-0001-000L5' 4. LEGAL DES CRIPTION (attach extra sheets if necessary): East of section 1 t o wn s h i p 34s Range 39E, lying N&W of Turnpike Feeder Road 5. PLAT BOOK 6. PAGE NO. 7. BLOCK NO. 8. LOT NO. 9. PARCEL SIZE (ACRES/SQ FT.): LOT DIMENSIONS: 10. COMPLETE DESCRIPTION OF CONSTRUCTION PROJECT OR WORK ACTIVITY: 11. SETBACKS (ACTUAL) FRONV ' BACK: 'S� RIGHT SIDE: ,k\ . LEFT SIDE:. 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) [g] NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ I INTERIOR RENOVATION (g] RESIDENTIAL [ ] COMMERCIAL (] INDUSTRIAL [ ] OTHER (SPECIFY) DESCRIPTION OF PROPOSED USE: Same SQ. FT OF CONSTRUCTION: _ 006, 1 15. SF. FT Ist FLOOR: VALUE OF CONSTRUCTION:" $ 51 , 000.00 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application. SLCCDV Form No.: 001-02 /LL vflCve ►"�S,J71 -3'yy CERTIFICATION: OWNER INFORMATION NAME: W nne Buil!ding Cor o ADDRESS: 8000 S . US!, 402 CITY: Port . S t Lucie STATE: FL_ ZIP: 34952 PHONE (DAYTIME): 17 7 2) s; 7 R 5 513 Email: IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: PHONE (DAYTIME): CONTRACTOR INFORMATION ZIP: St. of FL REG.CERT #: C G C 6 3 5 99 ST. LUCIE COUNTY CERT #: 0 8 8 9 8 BUSINESS NAME: Wynne Development Corporation QUALIFIERS NAME: Matthew L .1 e Wynne ..___ . 1 —; 4-- nne - ADDRESS: CITY: Port St. Lucie STATE: FL PHONE (DAYTIME): (7 7 2) 8 7 8— 5 513 FAX N0. 7 7 2— 8 7 8— 7 6 5 6 Email: ARCHIT/ENGINEER: Braden & Braden n l '7 Tvo ADDRESS: CITY: Stuart STATE: PHONE (DAYTIME): L 2 8 7— 8 2 5 8 BONDING COMPANY: ADDRESS: CITY: STATE: MORTGAGE LENDER: ADDRESS: CITY STATE: FL ZIP: 34996 ZIP: IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 daVs after notification it will be voided and returned to you by mail. This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, ETC., not otherwise included with this building permit application. St. Lucie County makes no representation that its granting of a permit will authorize the permit holder to build the subject structure which is in conflict with any -applicable Homeowner Association rules, bylaws or any covenants that may restrict or prohibit such structure. Please consult with your Homeowner's Association and review your deed for any restrictions which may apply. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all types), swimming -pools; fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: AS THE APPLICANT FOR THIS BUILDING PERMIT, IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT; AS A CONDITION OF THIS PERMIT YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and O. R G1 _ — IGNATURE ANT, STATE OF FLORIDA COUNTYOF St. Lucie The foregoing instrument was acknowledged before me this 55 � day of 4y &-4-S7T 20 / y , by Matthew T.yT e w/ysne who is personally known v or has produced identification. A. STATE OF FLORIDA COUNTY OF St. Lucie The foregoing instrument was acknowledged before me this day of AU 6--f S7_ 120 by Matthew Lyle Wynne who is personally known ✓ or has produced as identification. A. Signature of No ry s� Signature of N ,, DOROTHY ANN BASKIN ,s`�;y P" DOROTHY ANN BASKIN Commission No. `���"pv P�e� ate of Florida o e 's , otary P�eal�tCommission No. ; i - Notary ft4l State of Florida ' ` • e My Comm. Expires Oct 2, 2016 '_ • : : • e My Comm. Expires Oct 2, 2016 Commission # FF 015226 Commission # FF 015226 n,,,,,a Bonded Through National Notary Assn. Bonded Through National Notary Assn. NOTE: TWO (2) IrE A REQUIRED. EACH SIGNATURE MUST BE NOT ED. THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION. OWNER BUILDER AFFIDAVIT WILL BE REQUIRED FOR ALL OWNER/BUILDER APPLICANTS. For specific instructions see appropriate permit checklist. WYN . BUILDING CORPORAM-,A 8000 South U.S. #1 Suite 402 Port St. Lucie, FL 34952 Spanish Lakes Communities Division Port Saint Lucie September 22, 2014 To: St. Lucie County Building Department Attn: Permitting and/or Plan Review Re: 23 Villa Blanca Permit # 1408-0335 To Whom It May Concern: Miami Division Miami In regards to the above permit, the mobile home that was located on the lot was moved to 3 Jasmine in our Spanish Lakes One park. If you have any questions I can be reached at (772) 878-5513. T Matthew Lyle Wynne - V.P. Telephones: Port Saint Lucie (772) 878-5513 Miami (305) 235-3175 JOSEPH E. SMITH, CLERK 0! "E CIRCUIT COURT - SAINT LUCIE COUNT FILE # 3985551 OR BOOK PAGE 2580, Recorded 08/15/2014 at -,10 AM l� PERMIT NUMBER: I Thix tipuec L� rx't•r�eJ fur rccvrJiryt inter J r NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, end in accordance with Chapter 713. Florida statutes the following information is provided in the Notice of commencement. 1. DESCRIPTION OF PROPERTY ( gal description and street address) TAX FOLIO NumBER:l 301-11'{ — 0 0 0 1 - 0 0 0 sj oUVnCtry c u TRACT LOT BLDG UNIT SUBDIVLS�ON , 1 la;oBLOC , _r 1 t--such; n i4s Ranae 39E 2. GENERAL DESCRIPTION OF IMPROVEMENT: 3-t 3. OWNER INFORMATION: .a._.. 8000 S. US1r. Suite .402, eder Roa c, interest in property d. Name and address of (cc simple titleholder (if other than owner) 4.CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: Wynne Development Corporation 8000 S. U51 Suite 402 PSL, FL 3- 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the Stale of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1)(a) T. Florida Statutes: John Brennan NAME, ADDRESS AND PHONE NUMBER: I La 5 Cd S i t d s F t Pi etrP EL7naS1 77 �466 1553 8. In addition to himself or herself; Owner designates the: following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of correncement (the expiration date is 1 year from the dale of recording unless a different date is tm specified) ' 20 _ __ ,__, __ ,,,�r,ry na rnMMaNCEMENl• Matthew Lyle Wynne,ViCe—President Print Name and Provide Signatory's Title/OfficeSignature of Owner or Owner's Authorized OtTrcer/DirectorfPartner(Manager State of Florida County of St-- r t t r i ei/ 20� The foregoing instrument was acknowledged before me this day of., Matthew Lyle Wynne as R S � BY (Type of authority... e.g. owner, officer, trustee, attorney in fact) (Name Of person) For Wynne Building Corporation Personally Known �o rdu ed the fallowing eofW:— (Name of party on behalf of whom instrument was executed) � .a; a`�r DOROTHTHY ANN BASNIN binary Public . State of Florida My Comm. Expires Oct 2, 2015 IiD >CO Yi'{`r '• �� Commisdon M FF O1S22tS of N Public) I. '��h'%°;d,A' Bonded Through National Notuy Allen. (Printed Name of Notary u tc (Signature Under penalties of perjury, ( declare Ih have read the foregoing and that the facts in it are true to the best of my knowledge an belief (section 92.525. Florid. Stater Signatu ncr(s) or owner(s)' Author' ed Orricer/Director/Partner/Manager who signed above: By By: �,. 0Vson()07(R.-e IilQ R AT " fi r F. 1.11, 13 A T LUCIr r00N'ry St. Lucie County Building -& Zoning 2300 Virginia Ave `�oRioP Fort Pierce, FL 34982 BUILDING PERMIT SUB -CONTRACTOR SUMMARY . Wynne Building Corporation will be using the following sub-contractorsforthe (Company/Individual Name) `\ project located at� (Street address or Property Tax ID #) It is understood that if there is any change of status regarding the participation of any of the sub -contractors listed below, I will immediately advise the Building and Zoning Department of St. Lucie County. Trades Name of Company/Contractor St,Lucie County/ State of Florida License Number Electrical S & W Electric, Inc. 2045 ER0009416 Plumbing Lindquist Plumbing & Supply Co. 19150 CFC057672 HVAC/ Comfbrt Control of St. Lucie 8288 Mechanical CACO24379 Roofing Treasure Coast Roofing, LLC 19496 RC29027087. Gas PERMIT ``f I ISSUE DATE: NUMBER:. PERMIT # ISSUE DATE PLANNING & DEVELOPMENT SERVICES Building & Code Comp1buce Division RUI[LDICNG PERMIT SUB -CONTRACTOR AGREEN(ENT St. Lucie County Contractor Ce#ffication Number. 2045 State of Florida Certifioation Number (rapplicable): ER 0 0 0 2 4 i 6 S&W Electric have agreed to be the, (Company Nivie ndividual Name) RlActrical —Sub-contractor for Wynne Development Corp. ('lope of Trade) . (Primary Contractor) For the project located at (PMject Street Address or property Tax ID #) It is understood that, if there is any ebange of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by filing a Change of Sub -contractor notice. (Form: SI.CCDV (No. 004-00) BUSINESS QUALHUR (Name ofthe Individual shown on the Contractor's License) NOTARIZED SIGNATURES ARE REQUMED Business Name: S&W Electric Address: 501 W . Coker Rd. City/Stateaip; -Fort Fierce, FL_ 34945 Phone: (772) 464-6466 email: Lawrence Stubbs SIGNATURE PRINT NAME BATE STATE OF FLORIDA, COUNTY Ol" Cis _ THE FOREGOING IN3TRumwr WAS SIGNED BEFORE ME T1HIS� DAY OF J .20 BY )AW f .ua WHO IS PERSONALLY KNOWN _ OR HAS PRODUCED AS IDENTIFICATION. dWAtL 1,idyl J 10 t C1\A.[ 6 A (STAMP) SIGNATURE OP NOT X-Y PPUBLIC PRINT NAME OF NOTARY PUBLIU SLCPDS: 12/I6/2013 ,, LAURA R. CUBBEDGE ` Commission # EE 209915 Expires October 21, 2016 '°Q6 BondedTNuTroyFafnlnsuaice80D385.7019 Rl;d`� PLANNING & DEVELOPMENT SERVICES Building & Code Compliance Division r� a BUILDING PERMIT Iffivepar:. SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: 96901 State of Florida Certification Number (If applicable): CFC 1 4 2 8 4 5 8 Lindquist Plumbing have agreed to be the (Company Name/Individual Name) Plumbing Sub -contractor forWynne Development Corp. (Type of Trade) (Primary Contractor) For the project located at 12D `-� (Project Street Address or Property Tax ID It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by filing a Change of Sub -contractor notice. (Form: SLCCDV (No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) NOTAREZ,ED SIGI? T_1 TUR`k.,S ARE 3�.;"-,QUIr ED Business Name: Lindquist Plumbing Address: 3185 Sneed Rd. City/State/Zip: Fort Pier0e1 FL 34845 Phone: (7 7 2) 4 F 1 —1 9 F 9 email: Wade Case SIGNATURE PRINT NAME DATE STATE OF FLORIDA, COUNTY OF THE FOREGOING INSTRUMENT WAS SIGNED BEFORE ME THIS DAY OF Au G-N.3-r , 20_� BY 60 A4� C 6,45 E WHO IS PERSONALLY KNOWN ✓ OR HAS PRODUCED AS IDENTIFICATION. c I�CJ�1�o 'n (STAMP) SIGNATURE NOTARY PUBLIC PRINT NAME OF NOTARY PUBLIC SLCPDS: 12/16/2013 ,,yP, DOROTHY ANN BA]Assn. ��A �e Notary Public - State o • . . • My Comm. Expires Oct a r `41- Commission # FF 0 %� 0 �� ���� Bonded Through National N 01/14/2014 10:24 7728787;r-9.r WYNNE BUILDING QnRP PAGE 02/02 PERMIT #L . I ISSUE DATE PLANNING & DEVELOPMENT SERVICES Buildin+' & Code Colnpliance Division i )BUILDING PERMIT ISU� ONTRACTORAGREEMENT St. Lucie County Contractor Certification Numbeir- i State of Florida Certification Number (If appii4ie): CA.00 2 4 3 7 9 Comfort Control of St .- Lll i e County, Inc. have agreed to be the (Company Name/Individual Name) 1 air conditioning` (Type of Trade) For the project located at (Project St i cat It is understood that, if there is any cha age project, I will immediately advise the Buil Change of Sub -contractor notice. .(Form[ Sa 13USINESS QUALIFIER (Name, of NOTARIZED RGDT.ATURE, 8 ARY, R EQU Business Name: Comfort Coni Address: City/State/Zip: fort St. Luc Phone: (7 7 2)—. 7 85 a n y 41§RID pRIP -�� STATA, COUNTY OF C-�I THE FOREGOING INSTRUMENT WAS SIG] I3X 4_�7.rrt l �-i m »err. i 0, ub-contractor for Wynne Development Corp. (Primary Contractor) dress or Property Tax W #) ' 'status regarding our participation with the above mentioned ig and Zoning Department of St. Lucie County by filing a :DV (No. 004-00) II Individual slioAvn on the Contractor's License) PW ,t 01 of St. Lucie County, 'Inc. a+- t FL. 34983 c 4. email: AME DA77E D )BEFORE ME THIS DAY OF I WHO IS PERSONA AS IDENTIFICATION. PRINT NAMIE O�NOT�� U13IGIC �� .... .�..+ 20\ Y KNOWN ✓ OIt HAS (STAMP) =oeT °�iL^ Notary public State of Florida Jennie Knighommissi.t ?o►n°_A� Expire 08/15/2017 �5851' PLANNING & DEVELOPMENT SERVICES Building & Code Compliance Division BUILDING PERMIT SUIT -CONTRACTOR AGREEMENT St. Lucie County Cowaetor Certification Number: 1 9 496 State of Florida Certification Number (If applicable): RC2 9 0 2 7 0 8 7 Treasure Coast Roofing, UC have agteedto bo the (Company Name/Individual Name) 'Roof i ng Sub -contractor for Wynne bevelopment Corp (Type of Trade) (Primary Coutractor) For the project located at ,;�-) Nv N\G Street Address or Property Tax ID #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by filing a Change of Sub -contractor notice. (Porin: SLCCD'V (No. 004-00) BURNESS QUALIFIER. (Name of the Individual sbown on the Contractor's License) NOTARIZED SIGNATURES ARE 1RYQUI3S D BusinmName; Treasure Coast Roofingm LLC Address: 1816 Biltmore St. city/State/Zlp: Pmrt 9 0. T.ucier FL, 34984 Pbona: (772) 343-8308 _ eMail: A� � 1� � Brian Maloney <;e,\<,\\"1 SIGNATURE PRINT NAME DATE STATE OF FLORMA, COUN7['iC OF ,S-� !. vtc�1'.�. THE FOREGOING INSTRUMENT(' WAS SIGNED BEFORE ME'I'IIIS DAY OF BY �'� G` "� - YM k CX_9_ . WRO 1S PERSONALLY KNOWN �, OR HAS SxGNAE OFII! SLCPD 12/i6/x0713 AS IDENTIFICATION. (5TAA+IP) , Q-A Ln Lq PRINT NAME OF NOTARY PUBLIC ®U•NT ,Y- ST. LUCIE COUNTY BUELDING & ZONING 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 772-462-1553 FILLED LANDS AFFIDAVIT .1, the undersigned, am the owner of the following described property: /�� Range 39E, #1 301 1 1 1 0001 nnn 9- Fast- nf SPC" en 1 i (Tax ID/Legal descnption/Address)lying N&W of Turnpike Feede] for which I have applied to St. Lucie County for a Final Development Permit. In accepting this Final Development Permit, BP Number , I acknowledge that as owner of the above described property, and in accordance with Section 7.04.01(D), St. Lucie County Land Development Code, I shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely affected. I further acknowledge that in granting this permit for the development of this property, St. Lucie County is neither obliged nor liable to provide'for, or maintain in any form, adequate drainage off my property which will not adversely affect the immediate community. / Property Owner Name STATE OF FLORIDA. COUNTY OFFS t T usi- P ACKNOWLEDGED BEFORE ME THIS DAY OF 46-44i-r 20" BY AA-/We7A) y LI GJy1J1'SC' WHO IS PERSONALLY KNOWN TOME OR WHO HAS PRODUCED J� 0 SIGNATURE OF TARY NOTARY PUBLIC TITLE IDENTIFICATION. V o ,ear!-t �1 14 N )o TYPE OR PRINT NAME OF NOTARY (SEAL) COMMISSION NUMBER DOROTHY ANN BASKIN • � l�� Pub � Notary Public - State of Florida '• « » • My Comm. Expires Oct 2, 2016 OF F`°�a�e Commission # FF 015226 �•'",%W% Bonded Through National Notary Assn. r Planning & Development Services i "T!. 0 if g ��� .E.}•' E. Building & Code Regulation Division 2300 Virginia Ave Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT c®NSTRUCTION SOIL TREATMENT PERMIT #: ��10`6-0`33< 30B ADDRESS: d ('Aa 0c - BUILDER/CONTRACTOR: _ _ n �._ - .� _ .,,� ®o_ d—1 ,��_ . PEST CONTROL CONTRA( PEST CONTROL LICENSE We, the undersigned; hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association - Square feet if area treated: ._ Chemicals used: �n ? Percentage of solution: ,,0 CC Total gallons used: Date of Treatment: Footing 1�t Treatment Re -Treat Driveway, 1 Treatment Re -Treat Other 1st Treatment Re -Treat Time of Treatment: _a 1(I �S! 1st Treatment Re -Treat Pools 1� Treatment Re -Treat Perimeter for Final Inspection Signat re of Ext inator Note. There must be a completed form for each required treatment or re -treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled Inspection w111 fall and a-re-inspeci on fee charged. FBCi04.2.6 Certificate of Protective Treatmentforprevention of termites. A weather resistantjobslie posting board shall be provided to recelve duplicate Treatment Certificates as each required protectve treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment Certificate shall provide the product used, Identity of the applicator, time and date of the treatment, site 10060n, area treated, chemical used, percent concentration and number of gallons used, to estab&h a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention Is used, final exterior treatment shall be completed prior to final building approval. St Lucie County ne requires r the ii finalting all pthe treatments and dates of applicationsection for CO, a Permanent Sticker to . placed on the electrical p 3 qV -w 1 plianning & Da veOop pent Services Building & Code Reg ullatdon Division 2300 Vairgirda Ave part Filerce, Fl. 34982 772-462-2172 Fax 772-462-6443 OF TERMITE TREATMENT PERMIT 8'63 JOB ADDRESS: - 3 U t �1 r" BUILDER/ TRACTOR: ad d }-loll C GVLC1rc§*1Z— PEST CONTROL CONTRACTOR: — PEST CONTROL LICENSE #: We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with he standards of the National Pest Control Association. Square feet if area treated: Z�v Chemicals used: Percentage of solution: a ® b " Total gallons used: 1/4's- Date of Treatment: Z I �- -k 5' Footing Is' Treatment Re -Treat Driveway % 1s' Treatment Re -Treat !Lje—Treatr`nent Re-Treat Time of Treatment: JL11 Slab 1st Treatment Re -Treat Pools Ist Treatment Re -Treat Perimeter for F al Inspection Signature of Extermina or Note: There must be a completed fonn for each required treatment or re -treatment and th/s farm most be on the job site to be plclred up by the inspector at time of each inspection ar the scheduled Inspection will fall and a 're -inspection fee charged. FBC104.2.6 Certificate of Protective Treatment forpreventionoftennites. A weatherreslstantjobsifeposdngboard shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used, percent concentration and number ofgallons used, to establish a verifiable record of protective trea6nent. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final bullding approval. St Luele CGountV requires for the r1na8 inspection for CC, a penis inent Shaker to be placed on the eYedroeal panel box cover,, l'ostgng all the treatments and dates of applications. KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-�n il: K n��a KSME�I 11NEERING NET ST. LUCIE (772) 229-9093 C.A.: 5693 S�IL O1APA1 N REP8RT FAX (772) 589-6469 ASTM D 1557 and ASTM D 2922 DATE TESTED October 1, 2014 JOB # 141741-1 d/ES/km PERMIT # 14080335 CONTRACTOR Wynne Development Corp. JOB LOCATION 23 Villa Blanca Spanish Lakes Country Club Village Fort Pierce, Florida ITEM TESTED Compacted Foundation Fill TEST LOCATION *PEN DRY MAX. DRY PERCENT OF SAMPLE DEPTH READ DENSITY PROCTOR VALUE COMPACTION 1. N.E. 0" - 12" 40 105.8 110.0 96.2 2. N.W. 36 106.1 " 96.5 . 3. Center, 40 107.2 97.5 4. S.W. 32 107.0 97.3 5. S. E. 40 108.0 98.2 Soil Description: Light Brown and Gray Sand ,. In Place Moisture: 7.6 Percent. Optimum Moisture:. 11.2 Percent Max. Dry Density: 110.0 P.C.F. @ Test Locations The Density & Penetrometer Readings Indicate the Degree of Compaction Meets Mintrrm MIROg4ised `atipn Rljr ep to Natural Grade. R,es e-c ully` m�e`. O• ., o — t p ,aunty Building Department W E I I I I I I I 110.0—..—.�.—.. �.._.. I _.�—..—�.._.. . G I I I I I I I H I I I I I I T F 109.0 �.._.�.—..—..�..—.�—.—�...—..+. I I I I I I I C I I I I I I F 108.0 D R 107.0-.._.I.—..--I..—.. Y 8 9 10 11 12 13 14 15 Moisture - % of Dry Weight RECEIVED OCT 07 2014 E-mai� to:l�o�ty@spanishlakes.com Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 10/03/2014 13:23 7725896469 KSM ENGINEERING PAGE 01/01 'IVA KELLER, SCHILEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 PO. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) $45 $$76 E�Kp��yE REPO ST. LUGIE (772) 589-.6469 C.A.: 5693 }��3AA �j��jN���pO(�' FAX (772 ASTM D 1667 and ASTM D 2922 DATE TESTED October 1, 2014 JOB # : 141741-1d/ES/km PERMIT # : 14080335 CONTRACTOR ; Wynne Development Corp. JOB LOCATION 23 villa Blanca Spanish Lakes Country Club Village Fort Pierce, Florida ITEM TESTED Compacted Foundation Fill TEST LOCATION DEPTH PEN DRY MAX -DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N . E. 0" - 12" 40 105.8 110.0 96.2 2. N.W. if 36 106.1 tI96.5 3. Center 40 107.2 97.5 4. S.W. 32 107.0 97.3 5. S.E. 40 108.0 98.2 Soil Description: Light Brown and Gray Sand In Place Moisture: T6 Percent Optimum Moisture: 11.2 Percent Max. Dry Density: 110.0 P.C.F. @ Test Locations The Density & Penetrometer Readings Indicate the Degree of Compaction Meets Minimum tar st It -Feuv fe)l *Pr•�'I ear► ,, . IC a $1afNatural Grade. � Nl� j ul P �.�r deri Fax � E-mail 16atma W E I I I I I ! I l H 110.0 G I I I I I I I ( I I I T 109.0 I I I I I I I O I I i f I I D R 107.0 y a 9 10 11 17 11 14 11ri r Building Department Moisture - % of Dry Weight RECEIVED OCT Q12014 Wanishlakes. corn Ronald G. Koller, P.E.: 37293 / SI Lic- No.: 860 / Julie E. Keller, RE_: 68306 03/16/2015 11:51 7728787656 WYNNE BUILDING ,nFp PAGE 01/02 .4/1B/2014 15.29 77287 16 WYNNE BUILDING PAGE 02103 St- Lude C®aitraty Building & ZoWng Department ® %390 viromla,A,venue part rbree, FL 34992 772-462-2165 Fox772-A62-6443 Request for 30-Day Tempe i s y' Power Release F spit l� lbe . Property Address! THE ItT+�.IyUNDERSIGNED y��lylyE+�BySEByY REQUEST p �Z�E+gib,��EAgSgE7q�OYsgELECTRICAL �ggp'�+CgD�lq. yR �`O�yTHE q gip,(. A BO 1 fVEti7CSR IED pgo En /L & y FO RA �A FQ'i1t�R`�7BD 1' OT l� O JL'.1n�.�.ED EUR J4 (30) DAYS, S, R THE PURPOSE OF TESTING SYSTEMS AND EQUUMMT IN PREPARATION FOR FINAL I1NSIPF-CI•ION, IN cONSIIDERAT'ION OF APPROVAL OF TM REQUEST WE MERY ACKNOWLEDGEAND AGREE AS FOLLOWS: 1. This teiaipurary power release is requested for the above stated paarpose only, and'theremiil be no o4empancy of any type, otherAbo a got peOrt 496 by construction daring tleis dme period.' _ A,s'witnese by o+sx signatures, we tiereby MTN to Mde by VJl tarsus alld wnditsans u8 e7ii8 ag�reeaceat, ineludim$ l$aiidlu$ &Dividers poUcy, WWch is incer'poroledt esexelss by refefrence. �. AJl conditiot>,5 and requirgplents lasted in the attached document entitled "Requirements for 39 Day POwe r for Teatirag"• have been fWfiled and the paejuise is A'esdy for compliance inspection. 4. All requests Or an ®tttet)$'On beyond 30 days ammuSt be made in wdfmg to the Building Offs ial stadRg the rea60a for the request Power tray be moved booms the site and/or a stop Work tinder ismed if the Final Inspection has not been approved wiWn 30 days. A, fee of s100.00 will be ftgtzi ed•to lift the Stop WoVk Ordef- W HEREBY RELEASE AND .EAGUEZ TO HOLED HARMLESS, Sg-T. Ip.UCEE COUNTY, , v AND �R HEIR ]ElI�PLOYEVS �Fyit4y0�M ALL LIA IId�.IY' S AND Ca.R�'Yr1�►p.��'S��,. F ANY TYPE F NATURE WHICH MAY AR SB NOW OR IN THE �Ag: U gyOUT OF li LEA TRANSACTION, I3z4+i1JUDINO ,ANY JDA4a AGE WHICH BE .�1.VC RR9ED DUR TO THR DISCONNECTION i'R9 Off' ELEuRICAL POWE-a W EYENT9F VIOLATION OF TM AGREEMENT. LS7 W RECEIVED h"" 2 0 01/02/2015 14:32 7728787R�96 WYNNE BUILDING �QP PAGE 04/07 08/18/2014 15:29 77287 16 WYNNE BUILDING .L PAGE 02/03 `-1 C. U;N f Y . St- Lucie County Building & Zoning Department =0 Virghdat Avenue Fort Feree, FL 34982 7n-462.2165 ]?a% 772-462.6443 Request for 30-Day Tewperzr Power Release Date: Property Address: Permit Nwmbers THE uNI)ERSIGN +YD HEREBY EEQWST RELEASE OF ELECTIUCAL POWER TO THE ABOVE DESCRIBED PROPERTY, FOR A PERIOD NOT TO EXCUD THMTY (30) DAYS, FOR THE PURPOSE OF ItSTINC SYSTEMS AND )&QUWMEENT IN IREpARA 'ION FOR IMAM, INspEcTION. IN CONSEID)E RATION OF APPROVAL OF Tft REOWT WE NEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS: 1. Tnis tentpurary power release is req►nesteA got the above stated purpose only, ala there-v ill be no 4cCUpa►rcy of any type, other thaa owat, penatted by constra lion during this t1=6 �eriud. 2. ,A,s•wltnao by our sigcatures; we busby agme to albWe by alb WM and w n&5QAs of this agreemwt, in¢tndiag suildiag division Policy, whkh is incexparated herein by refer mer. 3. 911 condidoars and requirements lis4d In the agtac d document entitled "Regvirements for 30 Day rower for Testlne leave beefifulfffled and the prembe is ready for c®aragrif=i insjpectioa. 4. All requests for an extension beyond 30 days x,�ast be nade in writing to the Bnadisag 6lffficial slating the ream for the request ]Power may be mmoved from the site aAd/or a Stop Work Order issued if the Knai Inspection peas not been approved within 30 days. A, fee of 9100.00 will be xt gvdred-to lift the Stop Work Order. WE HEREBY REJLEASE'AND AGREE TO HOLD HARMLESS* ST. LUCIE CGVNTY, AND THEIR EMPLOYEES FROM Af LL LIA$ILITfES AND CLAIMS OF ANY TYPE OF NATURE WWCD MAY ARISE NOW OR IN THE FUTURE OUT OF TMS TRANSACTION, INCLUD)NG ANY DAMAGE WHICH MAY HE INCURRED DUE TO THE DISCON CTION OIL ELECTRICAL POWER FW4HE EVENT -OF VIOLATION OF THIS AGREEWNT. o ,0 0%j�� RSts",E 03/30/2015 13:15 7 7--37656 VJYNNE BUILP,-T-4177 CORP PAGE 01/02 .Pr®fessiolial Insulators Of South Florida FTC Insulation Inst,%Hat8on Certificate To: St Lucie Count Date! Re: March 23 2015 Lot/Block: .Address: 23 Villa Blanca Project: The undersi ned hereby certifies that insulation bas been installed in the above described fro er as follows: I. Exterior CBS walls have been insulated with: Thickness in inches: Spray -on Cellulose Manufacturer: li Foil Fiberglass Blankets )Density: hock Wool )Blankets R-'Value: 7 .Aluminum Foil X 4.1 l'3oard E1Hrigid Polystyrene Utber 2. Ceilings (level) have been insulated with: Spray -on Cellulose Manufacturer: .10.2511_ . _... _.....__ �.. _ . _.,_ Owens Corning g _ _.......,... hcr..glass Blown......... ---, mockWool Blankets t�luminum Foil -Value: 1�-30 polyurethane QD eat Cell SPF Ceilings (Inaccessible) insulated with: S ray -on Cellulose Thickness in inches: 9.5" % ]Fiberglass Ulankets Manufacture: Owens Corning Ignition Barrier JDensidy: Fiberglass 1319wae R-Value:-30 Cellulose Loose )will - -- open Cell SIPF 3, Interior kneewalls have been insulated with: Fiberglass Manket3 Thielcuess in inches: Fiberglass Loose Fi Manufacturer.- Rock Wool Density. ]VIBlown 2 R-Value: Cellulose Loose Fill Open, Cell SIRF 4. Garage partition walls of A/C living area have 7 Fiberglass Blanikets been insulated with:ock:'Vvol Thicknessin ineleest 3." polyurethane Manufacturer: Owens Corning Spray -oil Cellulose. Density: R-Value: Open Cell SPF 3. The following have been insulated: I ClBC1254041 Competency # Professional IRsU1ator8 of South Fioa Insulation Contractor By: s� eoga�aAae.yo�, �b��c6y7y ��� g�,• w �� 4�(�oyy • w. W .By: RECEIVED MAR 3 0 2015 • Termite Inspection Je5U5 Christ's t,orq -r2-323-7921 • Termite Pretreatment fflet-A-Toll Free: 1-877-365-9990 Pest Control Termite & • Rodent Service _Fax: 772-340-5990 Pest Fire Ant Lawn Service Controi, =Email: Evictabug@gmail.com ® Whitefly Treatment Inc. 2373 SW Woodridge St. • Licensed &Insured Lic. JB175775 - = - -� Port, -St: Lucie, FL 34953 Notice of Preventative Treatment for Termites (as required by Florida Building Code (FBC) 104.26, and Broward County Chapter FBC 105.2.2) PEST PREVENTION I " FIRE ANT SERVICE I TERMITE SERVICE I RODENT EXCLUSION &'REMOVAL I WHITEFLY TREATMENT DATE OF SERVICE. a �;," @ S� TIME DEVELOPMENT NAME (PROJECT)' CO T. ACTO�'S NAME CONTACT PERSON �Loc, STRUCTURE ADDRESS (LOT/BLOCK) .J CITY, STATE, ZIP CODE $$rj� COUNTY/ P, NOTES ,1� " z�A `oTREATMENT TYPEIAREA f J ❑ FLOATING . ❑ MONOLITHIC .W PATIO ❑GARAGE — DRIVEWAY ❑ STEM WALL/FOOTERS ❑ CUTOUTS, ❑ FOOTER, ❑ FRONT ENTRY ❑ RETREAT ❑ BORA CARE TREATMENT ❑ PLUMBING CUTOUTS ❑ TAMP & TREAT ` TREAT ONLY ,W FINAL ❑ POOL DECK ❑ OTHER, L3 ADDITION PRODUCTS s0 BASELINE ❑ DOMINION 2LACTIVE INGREDIENT Q BIFENTHRIN ❑ TERMIDOR SC ❑ BORACARE ❑ OTHER' ACTIVE INGREDIENT " O DISODTUM OCTABORATE'TETRAHYDRATE—, CONCENTRATION' 15 t ��Y 14,06% ❑ .12% ❑%0 ❑ .25 .05% ❑ 23% ❑ 9% ❑ OTHER GALLONS APPLIED ! .� SQUARE FOOTAGE ZY 6r) LINEAR FOOTAGE ` S SQUARE FOOTAGE VERIFIED ❑,YES ❑ NO d MEASURED OR: VERIFIED' PER PLANS JOB READY CONDITIONS MET ja'rYES ❑ NO DETAILS As per 104.2.6 FBC - If soil chemical barrier method for termite prevention is used. Final exterior treatment shall be completed prior to final building approval. Certificate of Compliance: The building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services. (Per the Florida Building Code.) If this notice is for the final exterior treatment, initial and date this line FINAL STICKER ❑ ELECTRICAL PANEL ❑ WATER HEATER ,OTHER Payment Terms: Payment due at time of service. ,. Date Ge�.� `� Applicator: (Evict A Bug Termite and Pest Control, InV) V\ `��✓r Date Customer (Property Owner or Agent) � TITAN Materials for Lifer gnmcretd, "Thank you;- We appreciate your business" Ticket no. FORT PIERCE 4199 SELVITT_' ROAD 2873SE, FT PIERCE FL _::498;=: Delivery date Plant JTruck Driver Truck size Type job • . t94i2/� t=28 1ff"`� WINf�F'IEL.U, GOI7FRE ' 3e 0 DR!VF,`W( Customer no. _ Customer name Zone Tax CD _ 'J000453� �.. I' R[7DNE Y HALL COW] f-2f. TE - CONS Tarmac project no. I Customer P.O. no. Order no. I Terms code 1-Charge delivered 3-C.O.D. Time due 4,4103, j 1. 7081 22!Charge FO.B. 4-C.0.1)-F.O.B. 12 N i28 Delivery name and address Lof Block County ST LUC I E COUNTY 23 VILLA BLANCAq FORT PIERCE Instructions TURNPIKE FEEDER RD. NORTH TO SPANISH LAKES BLVD, "f /L._ TO Slump CALLE DE Lt�C�O�,, l"/I__ TO VILLA 13LANCAo • 5. W Quantity LL 4�Pioduct4 3, U!M`. Unit.prce;.�Amount ; Load Cumulative Ordered Code Descriptiori '�� U 1 �'td I Iri I�if� r'TERF `ICER 1170 � 75 - CY t= ,'L. f)0 F�ri4 007 FUEWL [JRCHO LTy / 00 80( Q14 EISIV I RON Ci. RCI-ICE LD 1. 00 810+RI0; 6� OL-IORf LOAD LD i. Load Arrive job site Start discharge Finish discharge Leave job Is -It" Arrive plant ; f \ Subtotal Sales tax TOTAL kdditional water added to this concrete will reduce its strength. Any water added is at customer's risk. ; \ti�Sw Gallons of water added: Gallons of water added: Gallons of water added: q Amt of CY, Retained: Customer Approval: Customer Approval: CustomerApproval; CustomerApproval: Tested Tested properly No. ( ✓� «� _ ��<4uthorized and received by Yes ❑ No ❑Yes ❑ No �� I'\ Lot: Safety is a constant state of mind, with m /"! every employee feeling responsible Block: and empowered to act to cause him Address: Correct Not Correct and others to work safely, on the belief �` I RECEIVED FEB. 2 3 2015 that all accidents are preventable and that zero incidents is the only goal. rI ICTnfUFR rnpv TITAN FLORIDA LLC TERMS AND CONDITIONS OF SAL 1. All sales will be subject to these terms and conditions ("Contract") and, if buying on credit, to Buyer's credit agreement with Seller, incorporated herein by reference; all other terms, including any terms contained in Buyer's purchase order, are excluded unless agreed to by Seller in writing. Any changes must be in writing and signed by each party. This Contract will be construed in accordance with the laws of the state of Florida. For all disputes relating to this Contract, Buyer hereby consents to the jurisdiction and venue of the state and federal courts for the location of the delivery site of the goods sold hereunder. 2. Payment terms: Net the last day of the month following the month of delivery, without deduction, retainage, set off or charge backs. A. cash discount of 1 % 10" proximo may be deducted if no previous balances are past due, interest at the lesser of] 16% per month or the maximum rate allowed by law will be imposed on outstanding and delinquent invoices fron) the date of delivery until paid. Buyer will pay to Seller all applicable federal, state and local sales and use taxes. in addition to any other available rights and remedies, Seller will be entitled to recover from Buyer all costs of collection and litigation including, but not limited to, reasonable attorneys' fees. Seller reserves the right to require payments in advance or to cancel the unfilled portion of this Contract without notice in the event of Buyer default of any Contract provisions, or if the financial status of'Buyer becomes impaired or deemed unsat- isfactory to Seller. Failure of Seller to exercise any of its rights will not be deemed a waiver of any such right. 3. Regular delivery hours are 7:00 a.m. - 5:00 p.m., Monday tinrough. Friday. An additional charge may be added for deliveries outside of these hours and for any waiting/unloading periods in excess of 60 minutes. Prices are based on full loads; an additional charge will apply to loads of less than seven cubic yards. The minimum load for; each delivery is I'/, cubic yards. 4. Buyer will give Seller at least 48 hours prior notice of the time and rate of requested deliveries. Delivery schedules will be mutually agreed upon between Seller and Buyer. Deliveries will be made to the hest of Seller's ability to dispatch, however, Buyer waives any claims associated with any delays in delivery. ` 1 5. Buyer must provide suitable approaches to delivery points beyond paved streets. For delivery beyond curb lines, Buyer assumes all liability for damage to vehicles, sidewalks, driveways, pipes, septic tanks, and/or other property, and Buyer will indemnify and hold Seller harmless from and against any and all liability, loss and expense incurred as a result of such delivery, including but not limited to towing charges, except to the extent caused by Seller's gross negligence or willful misconduct. Buyer waives any right of subrogation against Seller. 6. Buyer is responsible for full payment of, including all costs of disposal and Seller's return charge per truck for, (i) orders not cancelled at least one hour prior to delivery time; (ii) concrete delivered due to Buyer's mistake or in excess of requirements; (iii) concrete not deliverable due to unsuitable approaches. 7. Concrete prices and quantities are based upon the wet volume at the time of discharge from the truck, and are not sold "form measurement" or measured "in place". Yield will be established in accordance with applicable ASTM standards. Buyer will pay all charges incident to inspection or tests made by or on behalf of Buyer. 8. Limited Warranty: Buyer is solely responsible for determining the type and quantity of goods to be purchased. Seller warrants that its products will meet or exceed applicable American Society for Testing Materials ("ASTM") and American Concrete Institute ("ACT") standards, when tested in accordance with ASTM and evaluated by ACT standards. Seller will repair or replace any goods supplied by Seller that fail to meet this limited warranty, within one year after delivery thereof. Seller will uphold its warranty obligations under Florida statute 718.203. as applicable, ALL OTHER WARRANTIES, WIIETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITAT'ION 111E WARRANTIES OF MERCITANTABILITYAND FITNESS FOR A PARTICULAR. PURPOSE, ARE HEREBY EXPRESSLY EXCLUDED. THE REMEDY SET .FORTH IN THIS SECTION 8 WILL CONSTITUTE THE SOLE REMEDY OF BUYER UNDER THiS LIMITED WARRANTY. 9. Seller will not be responsible for slump, strength or quality of any concrete to which water or other material has been added by or on behalf of Buyer.. Buyer will be responsible to see that the concrete is handled in accordance with best construction practices. Seller has no control over the placing or handling of concrete after unloading and does not guarantee the finished work. in which it is used. Buyer will be responsible to prevent concrete after unloading from coming into contact with any material, such as aluminum, which may adversely impact concrete strength. 10. Buyer will furnish any admixtures or ingredients it desires that are not regularly supplied by tlne Seller in the marketplace. Buyer will be solely respon- sible for the effect of such admixture or ingredients on the concrete. Any extra product which may be required in excess of the mix design quoted, or which may be required to provide workability, strength, setting time or water/cement ratio, will result in an additional ingredient charge payable by Buyer. I L Concrete will be hatched and delivered in accordance with ASTM C-94. Concrete temperature wi,11 be dictated by the environmental and material condi- tions at the time of delivery. Any requirement beyond these conditions will require the implementation of controlled measures (luring production at the expense of Buyer. 12. Buyer must give Seiler written'notice within 48 hours after delivery of any claim against Seller as a result of any alleged nonconforming materials or any other cause whatsoever (other than failure to meet compressive strength, in which event the time for notice will be within 48 hours after the customary time for analysis of the test cylinder), time being of the essence. Seller will be given reasonable opportunity to investigate all claims. Any failure by Buyer to give written notice within such 48 hour period will be deemed a conclusive waiver by Buyer of all such claims against Seller. 13. SELLER WILL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR ANY SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES INCLUDING, WITHOUT LIMITATION, ANY DAMAGES REI..AfED TO DELAY, WHETHER BASED ON STATUTE, TORT, CONTRACT, OR OTHERWISE, AND WHETHER OR NOTARISING FROM SELLER'S NEGLIGENCE, STRICT' LIABILITY OR FAULT. INNO EVENT WILL SELLER .BE RESPONSIBLE FOR DAMAGE DUE T'O TFfE ACTIONS OF OTFIERS OR THE FAILURE OF BUYER TO COMPLY WITH ITS OBLIGATIONS. SELLER'S LIABILITY FOR ANY CLAIMS WILL BE LIMITED TO T.F1E PURCHASE PRICE, OF THE GOODS SOLD UNDER THIS CONTRACT. 14. Notice. All notices to Seiler will be sent in writing to the sales office issuing the price quotation, with a copy to Credit Department, 455 Fairway Drive, Deerfield Beach, FL 33441. 15. Severability. The unenf'orceability of any provision of this Contract will not affect the enforceability of any other provision of this Contract, and each other provision of this Contract will be severable and enforceable to the extent permitted by law. WARNING: CAUSES SKiN IRRITATION - INJURIOUS TO EYES. CONTAINS PORTLAND CEMENT. FRESHLY MIXED CONCRETE MAY CAUSE SKIN IRRITATION OR INJURY. AVOID CONTACT WITH SKIN WHERE POSSIBLE. WASH EXPOSED AREAS PROMPTLY WITH WATER. IF ANY MIXTURES GET INTO THE EYE, RINSE IMMEDIATELY WITH WATER AND GET PROMPT MEDICAL ATTENTION. KEEP OUT OF REACH OF CHILDREN, MATERIAL SAFETY DATA SHEETS (MSDS) ARE A!%A LNBL.E AT WWW.TITANAMERiCA.COM. Rev'd 2-08 Al Ccmcx 56837189 °Plant: Begin -Loading; To°Job: < Ar""rive ;lab..° %aii Unloada , Fir ish UnI6ad. Leave Job: Retum Plant:` ^ 9 : ;. { 9: 4 " r Customer Code: Customer Name: Customer Job Number: Order Code / Date: Project Code; .� Project Name". ,< . .. Project P.O., Number: ,. .' Order P.O_ Number:. �l-d.7"��{_r-!5 f�`�L��v��.�C �d�4f 1 ��€�i.._ •��%�'�{�_. tad=Fi��"�L i�l��r��''r 4t�,���� (�L3i4�a��'- Ticket Date: Delivery Address; Map'Page: ` Map/Row/Column: :L{.t/2,4/;I4 e; a VERA CftiiUZ Delivery, Instructltiongs:7 Dispatcher: { g OFF:' y ( {yj �»r`MI :• O F: i.', I NG*,-t C�IW #., " n � , .. IDS a ... .. p Ticket Number: " i"'a i4id C. 3 Due On Job: Slump: Truck Number: Driver Number: Driver Name: End Use: r a I f{1 5.� 00 1 d l{�a J f La{_) � {ter �i r:� SOB CO—Ur� BLI3I.4 G. I�:4 � �MEI._. LOAD QUANTITY CUMULATIVE QUANTITY ORDERED QUANTITY MATERIAL CODE PRODUCTION DESCRIPTION UOM UNIT PRICE AMOUNT r} { o_ r"a fR{s 9. 001 1213F, 59) ,:r{.?<o() PRPM Its:, SAND •'tD8 i��'�i'1818 I[..:Ipllt�..TL SL.l1l�l�✓^�H(-'I,IR(:, 1.:. 1..,. 01) •.fr �3 �y P� .k..�»�„�E"»»�,,�4.'73 .l.'«,1 V Iir�SO��� AEN f r' L CHARGE .: ' Cash Check # / Auth Code: Signature of Driver Receiving Cash: Cash Received: Total COD Order Amount to Collect ] Check Without Standby Charges: Charge Comments: WATER ADDED: GAL YAR ,5, IN DRUM: ADDED. wG SIGNATURE CURB LINE CROSSED AT OWNER'S/AGENT'S REQUEST: rJNCRE T I DISPOSAL i" EEE SIGNATURE PARTIAL �'aL f=1 !!_L_. LOADY O """•""" -' ❑ LOAD WAS TESTED BY: Notice: Our "!• rivers will make every effort to place materials where the customer designates, but the SPECIAL TERMS: Any water added is at customers own risk. If water is added on job, concrete strength Company assumes no responsibility for damages inside curb or property line. Customer agrees to the is no longer guaranteed. WARNING: Product may cause skin and/or eye irritation. CAUTION: Material terms of sale and delivery and accepts concrete as is. Due to important factors which are out of our may be hazardous to your safety and health. Please refer to the backside of this ticket for important control after delivery, this Company will not accept any responsibility for the finished results. No credit for safety handling information, and to the material safety data sheets for additional information. returned concrete. Buyers exceptions and claims shall be deemed waived unless made to us in writing AUTHORIZED SIGNATURE: within one business day after the receipt of materials. O - 68UNIVERSAL PF,1EY TRS. a INVOICE LOAD NUM, 1 This Delivery Ticket incorporates herein. by reference Buyer's previously executed Credit Application, if any, Seller's Standard Terms and. Conditions, Seller's Quote , if any, and Seller's Order Confirmation uding limitations of warranties), as if fully set forth on this Delivery Ticket ("Ag---__lent"). Seller will provide the Standard Te....., and Conditions upon request. Buyer agrees that, unless otherwise noted on the front hereof, all quantities and items were delivered as indicated and further expressly agrees to pay in accordadce with the Agreement. AGGREGATE / CEMENT / CONCRETE PRODUCTS / FLY ASH Aggregate products are naturally occurring materials including limestone, dolomite, granite, volcanic rock, sand, gravel, and other siliceous materials. Cement products include Portland cement, masonry, pozzolan (Type IP), roof tile, and stucco. Concrete products include Portland cement and aggregate products including limestone, dolomite, granite, volcanic rock, sand, gravel, and other si.l.iceous materials. These products, including fly ash, may contain more than 0.025% crystalline silica. Hazards: Freshly mixed wet cement and/or fly ash can cause eye irritation, skin and eye burns and allergic skin reactions. Dry concrete and aggregate dust may cause irritation to eyes, skin, and/or respiratory tract. Dust from handling, crushing, grinding, cutting and/or drilling may contain silica, which may cause silicosis and cancer if inhaled. If ingested, keep warm, at rest, and drink large amounts of water. Fly Ash may contain trace amounts of ammo- nia. Moisture can cause the ammonia to be released. Inhalation of ammonia can cause coughing and irritation or burns of the nose, throat and lungs. See physician. Health risk depends on duration and level of exposure. Safety: Avoid contact with eyes and prolonged contact with skin. Wear gloves, eye protection, and appropriate protective clothing. Wash hands thoroughly with mild soap and water after handling. Avoid breathing dust. If exposed to dust above recommended limits (see MSDS), wear suitable NIOSH-approved respiratory protection. First Aid: In case of eye contact, ii.nmediately flush eyes with flowing water fo.r .15 minutes. If dust is inhaled, move to fresh air. If wet cement contacts skin, rinse thoroughly with water. Get proper medical attention il' irritation persists. CEMEX, Memorial Hermann Tower 929 Gessner, Suite 1900 V7 combined Houston, Texas 77024 02/12 For more information please visit www.cemexusa.com. Este ticket de entrega incluye como referencia al comprador (ya previamente ejecutada en su aplicaci6n de credito); cualquier t6rmino estandar, condiciones del vendedor, propuestas del vendedor y orden de confirmaci6n del vendedor (con limitaciones y garantfas), como acuerdo total del ticket de entrega ("Contrato"). El vendedor proveera los t6rminos estdndares y condiciones detal- lados en caso de asf ser reque.ridos. Con este documento, el comprador acepta los mismos ya antes mencionados y que ]as cantidades y materiales fueron entregados como se expresa en el mismo. Acepta pagar el monto de acuerdo a] contaato: al .menos que se identi- fique con una nota al frente de este documento. AGREGADOS / CEMENTO / PRODUCTOS DE CONCRETO / CENIZAS VOLANTES Los productos de agregados son materiales naturales como piedra caliza, dolomita, granito, roca volcdnica, arena, Brava y otros materiales silicios. Los productos de cemento incluyen Cemento de tipo Portland, de albanileria, pozzolan (tipo IP), azulejo de azotea y estueo. Los productos de concreto incluyen cemento Portland y productos de agregados como piedra caliza, dolomita, granito, roca volcdnica, arena, Brava, y otros materiales s.ilicios. Estos productos incluyen cenizas volantes (11y ash) la cual puede contener mas de 0.025% de silicio cristalino. Peligros: Mezcla de cemento fresco y/o cenizas volantes pueden causar irritaci6n en Jos ojos, quemaduras en piel y ojos, y reacciones al6rgicas en la pie]. Concreto seco y polvo de agregados, pueden causar irritaci6n en los ojos, piel y/o en la zona respiratoria. Polvo del manejo en el trituramiento, pul.ido, carte y/o perforaci6n puede contener materiales silicos, los cuales pueden causar silicosis pulmonar y cancer si son .inhalados. En caso de ser ingeridos, mantenerse en temperatura calida, reposar y tomar grandes cantidades de aqua. Las cenizas volantes pueden contener amoniaco. Seguridad• La humedad puede causar la liberaci6n del amoniaco. L,a inhalaci6n del amoniaco puede causar toser, irritacion o quemad ras eta la nariz, garganta y pulmones. Acudir i mled.iatamente al medico. El riesgo en la salad depende en la duraci6h y el nivel de la exposici6n. Segu.ridad.: Evite el contacto,epio;ojos y contacto prolongado con la piel. Use guantes, protecci6n en los ojos y .ropa Primeros adecuada para protecei6n. Lavese l.as manos con jab6n suave y agua despues del manejo de materiales. Evite inhalar auxilios: polvos. Si se expone a polvos mas de los limites recomendados, use protecti6n respiratoria. Primeros auxilios: En caso de contacto en los ojos, inmediatamente fluya aqua en la paste afectada por 1.5 m.inutos. Si se inhala polvo, exp6ngase a aire fresco. Si el cemento fresco tiene contacto con sus ojos, Idvelos a fondo con agua. Acuda a atenci6n medica inmediatamente si la irritacion continua. CEMEX, Memorial Hermann Tower 929 Gessner, Suite 1900 V7 combinado Houston, Texas 77024 02/12 Para mas informaci6n visita www.cemexusa.com. AF CEMEX 56837034 ' Plant' gin Loid!'ng":­ 6 JOb:' IT ve o 6 Sta"AUhlbad' Olnish'Uhilo'ad:f­ L6ave"Job:'�­ m '','ketuPlant: Customer Code: Customer Name: Customer Job Number: Order Code / Date: ,f i;'.: 'ONICRETE CONST ROT)NEY HAiLLIS C 118 2 0 1. Er 1. il Project Code: Project Name: 1 Project P.O. Number: Order P.O. Number, - 57, ­1t7)"' 1471ILL. 0 D V E,", I- ',RCTT""NEY� VEV�JB11'4L RKAYNIEV % Ticket Date: Delivery Address: Map Page: Map/Row/Column: F,./ 1. 4 22, VILL,P Delivery Instructions: 6e, I IV Dispatcher: L-ni,.t7-_s o,,7,F OF- HIGHWAY Ticket Number: A T A " WE A E % 33 19 5 4 Due On Job: Slump: Truck Number: -)643' 4 Driver Number: -Driver Name: End Use: B LIW3- SL B LOAD QUANTITY CUMULATIVE QUANTITY ORDERED QUANTITY I MATERIAL CODE PRODUCTION DESCRIPTION UOM UNIT PRICE AMOUNT f.34' 00 ()0 12, D tS 64., 1--?, 2500 REG/PIBER. MOING--FIBER Y, _-� 4 5184" FUEL, SLJP0_','Hi- 31E.' f '— 49 CAIARGE Cash Check #/ Auth Code: Signature of Driver Receiving Cash: Cash Received: Total COD Order Amount to Collect Without Standby Charges: Check ' WATER ADDED: GAL YARDS IN DRUM: WHEN ADDED. SIGNATURE 7 X.. CURB LINE CROSSED AT OWNER'S/AGENT'S REQUEST: UNCRETE, 'I) 1 3; P f, 3 S f 4;.. F P [-'I R T 1 P1 L Fu II) I— Y A R D S SIGNATURE Ll LOAD WAS TESTED BY: Notice: Our drivers will make every effort to place materjals where the ustom%e'r"dest'gnates, but the SPECIAL TERMS: Any water added is at customers own risk. If water is added on job, concrete strength Company assumes no responsibility for damages inside qdrb or property fine. Customer agrees to the is no longer guaranteed. WARNING: Product may cause skin and/or eye irritation. CAUTION: Material terms of sale and delivery and accepts concrete as is. JDue to important factors which are out of our may be hazardous to your, safle and health. Please refer to the backside of this ticket for Important -f ty data sheets for additional information. control after delivery, this Company will not accept any responsibility for a finished results. No credit for safety handling informatidn,,and, o the mateyu I-sa e, a returned concrete. Buyers exceptions and claims shall be\4ee ad v�pieed unless made to us in writing AUTHORIZED SIGNXTUKE within one business day after the receipt of materials. 68UNIVERSAL, PREV TRK- 1(-J4('-'*'5332 INVOICE LOAD NIUM - This Delivery Ticket incorporates, herein by reference Buyer's previously executed Credit Application, if any, Seller's Standard Terms and Conditions, Seller's ( ttion, if any, and Seller's Order Confirmat' ;including limitations of warranties), as if fully set forth on this Delivery Ticket ( reement"). Seller will provide the Standarc -ms and Conditions upon request. Buyer- agrees that, unless otherwise noted on the front hereof, all quantities and items were delivered as indicated and further expressly agrees to pay in accordance with the Agreement. Aggregate products are naturally occurring materials including limestone, dolomite, granite, volcanic rock, sand, gravel, and other siliceous materials. Cement products include Portland cement, masonry, pozzolan ('Type IP), roof tile, and stucco. Concrete products include Portland cement and aggregate products including Limestone, dolomite. granite, volcanic rock, sand, gravel, and other siliceous materials. These products, including fly ash, may contain more than 0.025% crystalline silica. Hazards: Freshly mixed wet cement and/or fly ash can cause eye irritation, skin and eye burns and allergic skin reactions. Dry concrete and aggregate dust may cause irritation to eyes, skin, and/or respiratory tract. Dust from handling. crushing, grinding, cutting and/or drilling may contain silica, which tnay cause silicosis and cancer if inhaled. If ingested, keep warm, at rest, and drink large amounts of water. Fly Ash may contain trace amounts of arnmo- nia. Moisture can cause the ammonia to be released. Inhalation of ammonia can cause coughing and irritation or burns of the nose, throat and lungs. See physician. Health risk depends on duration and level of exposure. Safety: Avoid contact with eyes and prolonged contact with skin. Wear gloves, eye protection, and appropriate protective clothing. Wash hands thoroughly with mild soap and water after handling. Avoid breathing dust. If exposed to dust above recommended limits (see MSDS), wear suitable NIOSH-approved respiratory protection. First Aid: In case of eye contact, immediately flush eyes with flowing water for 15 minutes. If dust is inhaled. move to fresh air. If wet cement contacts :skin, rinse thoroughly with water. Get proper medical attention if irritation persists. CEMEX. Memorial Hermann Tower 929 Gessner, Suite 1900 V7 combined Houston, Texas 77024 02/12 For more information please visit www.c-m-xusa corn. Este ticket de entrega incluye comp referencia al comprador (ya previamente ejecutada en su aplicaci6n de creclito); cualquier t6rmino estandar, condiciones del vendedor, propuestas del vendedor y orden de confirmaci6n del vendedor (con limitaciones y garantfas), coma acuerdo total clef ticket do entrega ("Contrafo"). El vendedor proveera Jos terminos estandares y concliciones detal- lados en caso de asf ser requeridos. Con este documento, el. comprador acepta los mismos ya antes mencionados y que las cantidades y materiales fueron entregados comp se expresa en el mismo. Acepta pagar el monto do acuerdo al contrato; at menos que se identi- fique con una nota al frente de este documento. AGREGADOS / CE.MENTO / PRODUCTOS DE CONCR.ETO / CENIZAS VOLA.NTES Los productos de agregados son materiales naturales corno piedra caliza, dolornita, granito, roca volcanica, arena; grava y otros materiales silicios..Los productos de cemento incluyen Cemento de tipo Portland, de albanilerfa, pozzolan (tipo IP), azulejo cic azotea y estuco. Los productos de concreto incluyen cemento Portland y productos de agregados corno piedra caliza, dolornita, granito, roca volcanica, arena, grava, y otros materiales silicios. Estos productos incluyen cenizas volantes (fly ash) la coal puede contener mas de 0.025% de silicio cristalino. Peligros: Mezcla de cemento fresco y/o cenizas volantes pueden causar irritaci611 en los Ojos, quernaduras err piel y ojos, y reacciones ale.rgicas en la pie]. Conc.reto seco y polvo de agregados, pueden causar irritaci6n en los ojos, piel y/o en la zona respiratorria. Po.lvo del manejo en el trituramiento, pulido, carte y/o perforac.i6n puede contener materiales silicos, los cuales pueden causar silicosis pulmonar y cancer si son inhalados. En caso de ser ingeridos, manterrerse en temperatura calida, reposar y tomar grander cantidades de agua. Las cenizas volantes pueden contener,-amoniaco. Seguridad• La humedad puede causar la liberaci6n del amoniaco. La inhalaci6n del. amoniaco puede causar toner, irritaci6n o quemaduras en la nariz, garganta y puhnones. Acudir inmediatamente at medico. El riesgo en la sakid depende en la duraci6n y el nivel de la exposici6n. Seguridad: Evite el contacto con ojos y contacto prolongado con la piel. Use guantes, protecci6n en los ojos y ropa Primeros adccuada para. protecci6n. Lavese ]as manos con jab6n suave y agua despues del manejo de materiales. Evite inhalar auxilios: polvos. Si se expose a polvos mas de Jos limiter recomendados, use protecci6n respiratoria. Primeros auxi.lios: En caso de contacto en los ojos, inmediatamente fluya agua on la parte afectada por 15 minutos. Si se inhala polvo, exp6ngase a aire fresco. Si el cemento fresco tiene contacto con sus ojos, lavelos a Tondo con agua. Acuda a atenci6n meciica inmediatamente si la inritaci6n continua. CF_,MEX, Memorial Hermann 'Tower 929 Gessner, Suite 1900 V7 conrbinado Houston, Texas 77024 02/12 Para rnas informaci6n visita www.cemexusa.com. 14� ;...37�4�� Plant: Beigih Loading;; ig, To aiil'un Iqad: Fini$h Uhl 66:: Leave'Job: Reiun Plant: 92 09E, Customer Code: Customer Name: customer Job Nur6ber. Order Code / Date: -7�02M' RODNEY HALLI c ��05 S CONCRETE CONILST I � �,8 10/ 1 G/ 14 .'Project Code: _ Protect- " - arne: Project P.O., Nu mber: Order P.O. Number: 0,931(Jii.­.'5�Gn °,'N'CMNEY, HALL 1 i)ERtIAL ROD VtKBAL I WD �4EY' Ticket Date: Delivery Address: Map Page: Map/Row/Column: 23, VILLA BLANCA Delivery Instructions: Dispatcher.1', *,H LAKES OFF, OF KINISS HIGHWAY '�A '%Plf-E Ticket Number: 1-101-LOW AT TYT ;.,TANcF,.!,. 319- Dua On Job: Slump: Truck Number: Driver Number: Driver Name: I End Use: ` 7.. 15 , 5. ()0" 11( �,) 64589 110f-.3229 -� NGEL DELATORRE BLDNIS3 SLAD LOAD QUANTITY CUMULATIVE QUANTITY ORDERED QUANTITY MATERIAL CODE PRODUCTION DESCRIPTION UOM UNIT PRICE AMOUNT 0. 00 .30. 0 0 ,7 1'4E`9664'6 E,'500 REG/FlIBER MONO—FIBER YD3., OCT 13 1247 618 FUIEL SURCHARGfE, .1. OiD, 1202749 ENY I RONMENTAL C'.11ARGE Cash Check# I Auth Code: Signature of Driver Receiving Cash: Cash Received: Total COD Order Amount to Collect Without Standby Charges: Check Charge r -SID Comments: WATER ADDED: —GAL YARDS IN DRUM: WHEN ADDED. V/ L,/ C.-, 'SIGNATURE CURB LINE CROSSED AT OWNER'S/AGENT'S REQUEST: NSPOSAL. F_ E E . PARTIAL FULL LO"'IT) YCAPJ.)�3 E SIGNATURE LPI L A U�WAS4-_T Notice: Our drivers will make every effort to place materials where the customer designates, but the SPECIAL TERMS: Any water added lslaTcustomers own risk. If water is added on job, concrete strength Company assumes no responsibility for damages inside curb or property line. Customer agrees to the is no longer guaranteed. WARNING: Product may cause skin and/or eye irritation. CAUTION: Material terms of sale and delivery and accepts concrete as is. Due to important factors which are out of our may be hazardous to your safety and health. Please refer to the backside of this ticket for important control after delivery, this Company will not accept any responsibility for the finished results. No credit for safety h4ndling information, and to the material safety data sheets for additional information. returned concrete. Buyers exceptions and claims shall be deemed waived unless made to us in writing' 'AUTHORIZED SIGNATU R,E: within one business day after the receipt of materials. 68UNIVERSAL P..,REV -rRK: LIDPil) KIM-. I INVOICE This Delivery Ticket incorporates herein by reference Buyer's previously exf -fti d Credit Application, if any, Seller's Standard Terms and Conditions, Seller's, Cation, .if any, and Seller's Order Confirma (including limitations of warranties), as if fully set forth on this Delivery T icket , —greement"). Seller will provide the Standar,, t arms and Conditions upon request. Buyer agrees that, unless otherwise noted on the front hereof, all quantities and items were delivered as indicated and further expressly agrees to pay in accordance with the Agreement. AGGREGATE / CEMENT / CONCRETE PRODUCTS / FLU' ASH Aggregate products are naturally occurring materials including limestone, dolomite, granite, volcanic rock, sand, gravel, and other siliceous materials. Cement products include Portland cement, masonry, pozzolan (Type 1P), roof tile, and stucco. Concrete products include Portland cement and aggregate products including limestone, dolomite, granite, volcanic .rock, sand, gravel, and. other siliceous materials. These products, including fly ash, may contain more than 0.025% crystalline silica. Hazards: Freshly mixed wet cement and/or fly ash can cause eye irritation, skin and eye burns and allergic skin reactions. Dry concrete and aggregate dust may cause irritation to eyes, skin, and/or respiratory tract. Dust from handling, crushing, grinding, cutting and/or drilling may contain silica, which may cause silicosis and cancer if inhaled. If ingested, keep warm, at: rest, and drink large amounts of water. Fly Ash may contain trace amounts of ammo- nia. Moisture can cause the ammonia to be released. Inhalation of ammonia can cause coughing and irritation or burns of the nose, throat and lungs. See physician. Health risk depends on duration and level of exposure. Safety: Avoid contact with eyes and prolonged contact with skin. Wear gloves, eye protection, and appropriate protective clothing. Wash hands thoroughly with mild soap and water after handling. Avoid breathing dust. ti' exposed to dust above recommended limits (see MSDS), wear suitable NIOSH-approved respiratory protection. First Aid: In case of eye contact, immediately flush eyes with flowing water for 15 minutes. If dust is inhaled, move to fresh air. If wet cement contacts skin, rinse thoroughly with water. Get proper medical attention if irritation persists. CEMEX, :Memorial Hermann Tower 929 Gessner, Suite 1900 V7 combined Houston, Texas 77024 02/12 For more information please visit wwwcer»exu�a,com.. Este ticket de entrega incluye como referencia al comprador (ya previamente ejecutada en su aplic.;aci6n de crEdito): cualquier termino estlndar, condiciones del vendedor, propuest:as del vendedor y orden de confirmaci6n del vendedor (con limitaciones y (yarantfas), como acuerdo total del ticket de entrega ("Contrato")..El vendedor proveerd los terminos estindares v conchciones detal- lados en caso de asf ser requeridos. Con este documento, el comprador acepta los mismos ya antes mencionados y que las canticiades y materiales fueron entregados como se expresa en el mismo. Acepta pagar el monto de acuerdo al contacto; al mends quc se identi- fique con una nota al frente de este documento. AGREGADOS / CEMENTO / PRODUCTO.S DE CONCRETO / CENIZAS VOLANTES Los productos de agregados son materiales naturales como piedra caliza, dolomita, granito, coca volc6nica, arena, grava y otros materiales silicios. Los productos de cemento incluyen Cemento de tipo .Portland, de albanilerfa, pozzolan (tipo IP), azulejo de azotea y estuco. Los productos de concreto incluyen cemento Portland y productos de agregados como piedra caliza, dolomita, granito, rota volcanica, arena, grava, y otros materiales silieios. Estos productos incluyen cenizas volantes (fly ash) la coal puede contener m1s de 0.025% de silicio cristalino. Peligros: Mezcla de cemento fresco y/o cenizas volantes pueden causar irritaci6n en Jos ojos, quemaduras en piel y ojos, y reacciones alergicas en la piel. Concreto seco y polvo de agregados, pueden causar irritaci6n en .los ojos, pie] y/o en la zona respiratoria. Polvo del mancjo en el trituramiento, pulido, carte y/o perforaci6n puede contener materiales silicas, los cuales pueden causar silicosis pi.Gltnonar y cancer si son inhalados. En caso de ser ingeridos, mantenerse en temperature calida, reposar y tomar grander cantidadgs de agua..Las cenizas volantes pueden contener amoniaco. Seguridad• La humedad puede causar la liberaci6n del amoniac,o. �l'a inhalaci6n del amoniaco puede causar toner, irritaci6n o quemaduras en la nariz, garganta y pulmones. Acudrr inmediatamente al medico. El riesgo en la salad depende en la duraci6n y el nivel de to exposici6n. Seguridad: Evite el contacto con ojos y contacto prolongado con la picl. Use guantes, protecci6n en los ojos y ropa Primeros adecuada para protecci6n. Ldvese las manos con jab6n suave y ague despues del manejo de materiales. Evite inhalar auxilios: polvos. Si se expone a polvos rues de los limites recomendados, use protecci6n respiratoria. Primeros auxilios: En caso de contacto en los ojos, inmediatamente fluya agua en la parte afectada por 15 mimltoS. Si se inhala polvo, exp6ngase a aire fresco. Si el cemento fresco tiene contacto con sus ojos, tdvelos a fondo con agua. Acuda a atenci6n medica inmediatamente si la irritaci6n continua. CEMEX, Memorial.Hermann Tower 929 Gessner, Suite 1900 V7 conrbinado Houston, Texas 77024 02/12 Para etas informaci6n visita www.cemexusa.com. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. MiTek' RE: ml 1324 - 70' Carlton Elev D MITek USA, Inc. 6904 Parke East Blvd. Site Information: Tampa, FL33610-4115 Customer Info: WYNNE BUILDING CORPORATIN Project Name: m11324 Model: Lot/Block: Subdivision: Address: 23 Villa Blanca City: ST LUCIE State: FL ' Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2010/TP12007 Design Program: MiTek 20/20 7.3 Wind Code: ASCE 7-10 [All HeighII Wind Speed: 165 mph Roof Load: 32.0 psf Floor Load: N/A psf This package includes 26 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet f En ineers Rules. conforms to 61 G15 31.003, section 5 of the Florida Board oProfessionalg No. Seal# Truss Name Date No. Seal# Truss Name Date 11 IT6391319 Al 6/30/014 18 T6391336 JA 6/30/014 12 I T6391320 I A2 16/30/014 119 I T6391337 I J B 16/36/014 I 13 I T6391321 I A3 16/30/014 120 I T6391338 I JC 16/30/014 1 14 I T6391322 I A4 16/30/014 121 I T6391339 I KJ5 16/30/014 15 I T6391323 I A5 16/30/014 122 I T6391340 I KJ7 16/30/014 16 I T6391324 I A6 16/30/014 123 I T6391341 I KJA 16/30/014 I 17 IT6391325 IA7 16/30/014 124 I T6391342 I KJB 1 6/30/014 I 18. I T6391326 I A 16/30/014 125 I T6391343 I MV2 16/30/014 I 19 I T6391327 I B 16/30/014 1 26 I T6391344 I MV4 1 6/30/014 I 110 I T6391328 I BH7 16/30/014 I I I ' I I I Ill IT6391329 I GRA , 16/30/014 112 IT6391330 IGRB 16/30/014 113 I T6391331 I GRC 16/30/014 114 I T6391332 IA 1 16/30/0141 115 I T6391333 I J3 16/30/014 116 I T6391334 I J5 16/30/014 117 I T6391335 I J7 16/30/014 The truss drawing(s) referenced above have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided by Chambers Truss. Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2015. IMPORTANT NOTE: Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. t pUI N *: �68182 .•*. STATE OF .' J N A' ��1,��• FL Cert. 6634 June 30,2014 Velez, Joaquin 1 of 1 Job Truss Truss Type Qty Ply 70' Carlton Elev D T6391319 m11324 Al SPECIAL 9 1 ob Reference (optional) Chambers Truss Inc., Fort Pierce Fl. 34982 r.sou s bep z1 zuiz ivu i eK mcusmes, inc. man uun au i i:ie:ia zui4 rage i ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-o??4rUlygIC51 OG7Ae8yGTZ6tLGiHkGGdQn6QAz17GC * 1-0 13-7-8 17-0-0 23-11-12 26-9-10 35-0-0 6-0 'o 7-B-0 5-11-8 3-10-8 6-5-12 2-9-14 B-2-6 10 Scale = 1:60.3 4.00 12 5x6 = 4x4 = 14 13 4x8 2x3 II 5x12 = 2.00 12 7-8-0 13-7-8 23-11-12 35-0-0 7-8-0 5-11-8 10-4-4 11-0-4 Plate Offsets (X Y)7 [2.0-3-14 Edge] [8.0-3-0 Edoel r10:0-5-2 Edgel LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.86 Vert(LL) 0.76 12 >539 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.83 Vert(TL) -1.30 12-13 >317 240 MT18HS 2441190 BCLL 0.0 ' Rep Stress Incr YES WB 0.48 Horz(TL) 0.39 10 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix) Weight: 158 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-0-1 oc bracing. WEBS 2x4 SP No.3 `Except' WEBS 1 Row at midpt 6-12 6-12: 2x4 SP M 30 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer [installation guide. REACTIONS (lb/size) 2=1021/0-8-0 (min. 0-1-8), 10=1023/0-8-0 (min. 0-1-8) Max Horz 2=224(LC 7) Max Uplift 2=-837(LC 8), 10=-837(LC 8) Max Grav 2=1171(LC 2), 10=1171(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=2741/1788, 3-4=-2154/1460, 4-5=-2097/1474, 5-6=-2129/1562, 6-7=-4406/2927, 7-8=-4337/2831, 8-9=-4384/2824, 9-10=-4785/3126 BOT CHORD 2-14=-1582/2548, 13-14=-1582/2548, 13-1 5=-1 02311828, 15-16=-1018/1832, 12-16=-1017/1840, 10-12=-2876/4512 WEBS 3-13=-631/465, 5-13=-271/242, 6-13=-269/469, 6-12=-1740/2753, 7-12=-258/249, 9-12=-388/377 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 5.Opsf. 6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate -capable of withstanding 837 lb uplift at joint 2 and 837 lb uplift at joint 10. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Qv I N V i Nic 68182 :�• T OF : 1/' • • O,. ' ,��111111111111 FL Cert. 6634 June 30,2014 & WARMAG - V.dfy d.19. parame onn and READ MITES ON TUrSAND INCLUDED MrTEKREFEREACE PAGE MU-7473 rex 1/24/1014BOUREME !� Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MiTek• erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI7 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information 7vo able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA Z2314. Tampa, FL 33610.4115 115authernPine SP lumber isspecified,thedesign values are those effective 05i0212013byALSC Job Truss Truss Type Qty Ply 70' Canton Elev D T6391320 m11324 A2 SPECIAL 1 1 ob Reference o do al Chambers Truss Inc., Fort Pierce H. 349az r.00u s _rP �� co i� rvu i cn niausnies, mc• a . <v , a9, I ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-o??4rUIygIC51 OG7AeByGTZ6sLFIHgkGdQn6QAzl7GC lx 1-0 7-8-0 13-7-8 17-0-0 18-0- 23-11-12 26-9-10 35-0-0 6-0 -0-0 7-B-0 5-11-8 3-4-8 -0-0 5-11-12 2-9-14 8-2-6 0-0 Scale = 1:62.3 4.00 12 4x4 % 4x5 6 7 4x4 = - 17 16 3x4 = 4x8 = 2x3 II 6x12 = 3x5 2.00 12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d TCLL 20.0 Plates Increase 1.25 TC 0.86 Vert(LL) 0.76 13 >540 360 TCDL 7.0 Lumber Increase 1.25 BC 0.86 Vert(TL) -1.19 11-13 >347 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.70 . Horz(TL) 0.42 11 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix) LUMBER TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS (lb/size) 2=986/0-8-0 Max Harz 2=218(LC 7) Max Uplift 2=-837(LC 8) Max Grav 2=1171(LC 2; (min. 0-1-8), 11=986/0-8-0 (min. 0-1-8) 11=-837(LC 8) 11=1171(LC 2) PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: 168 lb FT = 0% BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-0-9 oc bracing. WEBS 1 Row at midpt 8-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2746/1787, 3-4=-2132/1457, 4-5=-2075/1471, 5-6=-1998/1418, 6-7=-1880/1381, 7-8=-2019/1397,8-9=-4321/2829,9-10=-4369/2821,10-11=-4778/3131 BOT CHORD 2-17=-1580/2533, 16-17=-1580/2533, 15-16=-117412004, 14-15=-101311855, 13-14=-2504/4176, 11-13=-2882/4503 WEBS. 3-16=-675/465, 5-15=-287/192, 6-15=-379/503, 7-14=-242/437, 8-14=-2499/1605, B-13=-955/1626, 10-13=-413/387 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load noncbncurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 837 lb uplift at joint 2 and 837 lb uplift at joint 11. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard ,&WARNING -Verity design pa. —Mrs and READ M7TESO1171LISAM) INCLUDED Mr1EKREFEREM'f PAGENII-7473 rea 1/29/201JEfFOAEUSE Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI7 Quality Criteria, DSB-B9 and BCSI Building Component Safety Information gqvauuable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. 7fSauthernPinelSP)lumberisspeci#ied',thedesignvaluesarethaseeffectiveD6 01/2013b°yALSC `, �`�Qv I N "VF ����i o 0P,. <� . io o lo N 68182 :�• T OF ` �I� rs •• •... �?,� N FL Cert. 6634 June 30,2014 my MiTek' 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type Qly Ply Elev D T6391321 ml 1324 A3 SPECIAL 1 1 [O'Carlton Job Referenge (optional) Chambers Truss Inc., Fort Pierce FI. 34952 r.— s —P <r <u 4 rvn i as mausnrcs, mc. M u 11. M Vi 26 w r4Y1 , ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-GBZS3gJabbKyfYrJkMfBoh5JAIbeO3nQr4Wgzdzl7GB it 1-0 B-0-1 15-0-0 20-0-0 23-11-12 26-9-10 35-0-0 6-0- -0-0 8-0-1 6-11-15 5-0-0 3-11-12 2-9-14 8-2-6 -M 4.00 12 4x5 % 4x4 4x4 = 15 - 4x8 = 2x3 11 5x6 = 2.00 12 Scale = 1:62.3 8-0-1 13-7-8 20-0 0 23-11-12 35-0-0 8-0-1 5-7-7 6-4-B 3-11-12 11-0-4 Plate Offsets (X Y)• [270-3-14 Edge] 1970-3-0 Edge) 110.0-5-2 Edgy LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.76 Vert(LL) 0.68 12 >605 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.85 Vert(TL) -1.14 10-12 >363 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.97 Horz(TL) 0.38 10 n/a n1a BCDL 5.0 Code FBC2010/TPI2007 (Matrix) Weight: 159 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS (lb/size) 2=986/0-8-0 (min. 0-1-8), 10=986/0-8-0 (min. 0-1-8) Max Horz 2=194(LC 7) Max Uplift 2=-837(LC 8), 10=-837(LC 8) Max Grav 2=1171(LC 2), 10=1171(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2729/1771, 3-4=-2607/1786, 4-5=-2104/1448, 5-6=-2324/1632, 6-7=2452/1671, 7-8=-4324/2787,8-9=-4610/3102,9-10=-4723/3088 BOT CHORD 2-15=-1575/2516, 14-15=-1575/2516, 13-14=1128/1961, 12-13=-2458/4129, 10-12=-2848/4446 WEBS 4-14=-718/514, 5-13=-272/588, 6-13=-306/516, 7-13=-2100/1327, 7-12=-939/1576, 8-12=-412/397 Structural wood sheathing directly applied or 2-2-0 oc purlins Rigid ceiling directly applied or 4-1-13 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C, Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) The solid section of the plate is required to be placed over the splice line at joint(s) 12. 5) Plate(s) at joint(s) 12 checked for a plus or minus 2 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load ndnconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 837 lb uplift at joint 2 and 837 lb uplift at joint 10. 10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard ®WARMIG-yerffrdesign yarameters and READ N07ESDN71,7SAND rMaLIDED MrFEKREFEREALE PAGE N11-7473 ra.1/29/2014BU R UM Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity of the erector. Additional pennonent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Cdterla, DSB-89 and BCSf Building Component Safety Information gqv0i able from Truss Plate Institute, 781 N. Lee Street, Suite 312. Alexandria, VA 2314. 1f5fluthernPinelSP�lumberisspecified, the design values are these effective 06 01/2u13byALSC 0\31 N NS 0 N 68182 T OF 00 FL Cert. 6634 June 30,2014 MiTek' 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply ' Carlton Elev D T6391322 Eb m11324 A4 SPECIAL 1 1 Reference (optional Chambers Truss Inc., Fort Pierce FI. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Mon Jun 30 11:19:15 2014 Page 1 ID: _kfiGCA6bx7j2Syl HDXFw7ye3KK-kO7gGAJCMvSpHhQV13AQLueRe9xoIW1Z4kGDV3z17GA > 1-0 7-8-0 13-0-0 22-0-0 23-11-12 26-9-10 35-0-0 6-0 -0-0 7.8-0 5-4-0 9-0-0 1-11-12 2-9-14 8-2-6 -0-0 4x4 = 5x10 5x6 = 3x6 C 4.00 12 4 5 6 13 2x3 II 5x12 = 2.00 F12 4x8 = Scale = 1:61.3 7-B-0 13-7-8 22-0-0 ,23-11-12 , 35-0-0 7-8-0 5-11-8 8-4-8 1-11-12 11-0-4 Plate Offsets (X Y): I2:0-3-14 Edged f4.0-5-0 0-2-0), [8:0-5-2 Edge] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.85 Vert(LL) 0.70 10 >590 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.86 Vert(TL) -1.14 8-10 >362 240 MT18HS 2441190 BCLL 0.0 Rep Stress Incr YES WB 0.99 Horz(TL) 0.38 8 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 157lb FT=O% LUMBER BRACING TOP CHORD 2x4 SP M 30 `Except` TOP CHORD Structural wood sheathing directly applied. 4-5: 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 4-1-3 oc bracing. BOT CHORD 2x4 SP M 30 MiTek recommends that Stabilizers and required cross bracing WEBS 2x4 SP No.3 be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=986/0-8-0 (min. 0-1-8), 8=986/0-8-0 (min. 0-1-8) Max Horz 2=170(LC 7) Max Uplift 2=-837(LC 8), 8=-837(LC 8) Max Grav 2=1171(LC 2),8=1171(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2732/1777, 3-4=-2167/1493, 4-5=-3002/2033, 5-6=-3106/2070, 6-7=-4297/2756, 7-8=-4794/3146 BOT CHORD 2-13=-1570/2517, 12-13=-1570/2517, 11-12=-1195/2039, 10-11=-2412/4080, 8-10=-2897/4519 WEBS 3-12=-626/420, 4-11=-616/1112, 5-11=266/557, 6-11 =1 556/940, 6-1O=980/1602, 7-10=-527/494 NOTES ,`,111111111/���, 1) Unbalanced roof live loads have been considered for this design. IN VF 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. ,,�� AQU ,� OP (� �� E IV 3 �• `� II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.f0 plate grip DOL=1.60 ,� , ••G d� F•�•, 3) Provide adequate drainage to prevent water ponding. w •� ; 4) All plates are MT20 plates unless otherwise indicated. N 68182 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. * 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify — '0 capacity of bearing surface. i T O F �• 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 837 lb uplift at joint 2 and 837 lb uplift at 8. _ �(/ �� •. /c P joint 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. .' �� �i •'� �� LOADCASE(S) Standard //11J111111 FL Cert. 6634 June 30,2014 %WARfKNG-Vefffrdesign Paramea:rs and READ ROTES ON 7NIS.AND IM1aDED NITEKREFERE&CE PAGE NII-7473. ,1129110I4BFFOAEUSE Design valid for use only with Welk connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MiTek• erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing. consult ANSI/TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informatlon gvaJable from Truss Plate Institute. 781 N. Lee Street, Suite 312. Alexandria, VA2314. Tampa, FL 33610.4115 ItSauth. pine Sp lumberisstrecifterLthedesienvaluesaretheseeffective061,0112013bvALSC Job Truss Truss Type Qty Ply Elev D [O'Carlton T6391323 m11324 AS SPECIAL 1 1 Job Reference (optional Chambers Truss Inc., Fort Pierce Fl. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Mon Jun 30 11:19:15 2014 Page 1 I D:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-k07gGAJCMvSpHhQ\/13AQLueQp9x9lavZ4kGDV3zl7GA 1-0 7-10-13 11-0-0 17-11-10 24-0-0 26-8-1 35-0-0 6-0 -0-0 7-10-13 3-1-3 6-11-10 6-M 2-8-1 8-3-15 -0-0 5x10 4.00 12 13 3x4 = 5 45 14 6 y Scale = 1:61.3 4x4 = 12 4x8 = 11. 3x4 = 5x6 = 2.00 12 11-0-0 13 11 23-11-12 _ 35-0-0 11-0-0 2-7-8 104-4 11-0-4 Plate OffsetslX Yr f2:0-3-14 Edael f4.0-5-0 0-2-01 f8.0-5-2 Edael LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 7.0 Lumber Increase 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 5.0 Code FBC2010/TPI2007 CSI DEFL in (loc) I/defl L/d TC 0.90 Vert(LL) 0.74 10 >555 360 BC 0.83 Vert(TL) -1.21 10-11 >341 240 WB 0.72 Horz(TL) 0.39 8 n/a n/a (Matrix) LUMBER BRACING TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS (lb/size) 2=986/0-8-0 (min. 0-1-8), 8=986/0-8-0 (min. 0-1-8) Max Horz 2=146(LC 7) Max Uplift 2=-837(LC 8), 8=-837(LC 8) Max Grav 2=1171(LC 2), 8=1171(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2691/1791, 3-4=-2368/1605, 4-13=2371/1648, 5-13=-2370/1648, 5-14=-4103/2666, 6-14=-4103/2666, 6-7=4353/2795, 7-8=4790/3131 BOT CHORD 2-12=1581/2480, 11-12=-1307/2219, 10-11=-2041/3253, 8-10=-2881/4516 WEBS 3-12=400/355, 4-12=-1711351, 4-11 =-1 81/348, 5-11=-1096/784, 5-10=-444/964, 6-10=748/1211, 7-10=-466/436 PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: 151 lb FT = 0% Structural wood sheathing directly applied. Rigid ceiling directly applied or 3-11-14 oc bracing MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 837 lb uplift at joint 2 and 837 lb uplift at joint B. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard ®WARNIAG-Vdtydesign par .M.and AEA➢ A07ESON711I6ANDINaLIDED MITEKRFFERENCE PAGE NII-7473 mR 112912014BDUWVSE Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component Safety Information QvaUable from Truss Plate Institute, 781 N. Lee Street. Suite 312. Alexandria, VA 22314. If Sauthern Fine SP lumber is specified the design values are those effective 0510212013 byALSC t"till If tilt QUIN %%� OP. • ,�.` .•�,�G•E NSF•.? i N 68182 T OF 0 FL Cert. 6634 June 30,2014 y MiTek' 6904 Parke East Blvd. Tampa, FL 33610.4115 Job Truss Truss Type Qty Ply 70' Carlton Elev D T6391324 m11324 A6 HIP 1 1 Job Reference (optional) Chambers Truss Inc., Fort Pierce FI. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Mon Jun 30 11:19:16 2014 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-CagCU WKg6Dagur?isnhfu6BcMZJKUBYiJO?ml Vzl7G9 -8-0 i 1-0- 9-0-0 1320-2-13 26-M 35-0-0 6-0 0-0 9-0-0 4 B-0 6 6-13 5-9-3 9-0-0 0-0 4.00 12 5x10 2x3 11 46 = 2x3 11 5x10 3 16 17 4 5 6 18 19 r Scale = 1:60.3 4x4 = 15 14 13 12 11 10 4x4 = 2x3 II 4x6 _ 3x4 = 3x4 = 3x6 — 2x3 II 9-0-0 13-8-0 213 3 26-0-0 35-0-0 9-0-0 4-8-0 IS 2, 5-9-3 9-0-0 Plate Offsets (X Y)7 [270-3-10 Edgel 13.0-5-0 0-2-01 f5.0-3-0 Edgej 17:0-5-0 0-2-0), [8.0-3-14 Edge] LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 7.0 Lumber Increase 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 5.0 Code FBC2010/TPI2007 CSI DEFL in (loc) I/defl Lid TC 0.85 Vert(LL) 0.6810-12 >373 360 BC 0.71 Vert(TL) -0.91 10-12 >278 240 WB 0.32 Horz(TL) 0.11 8 n/a n/a (Matrix) LUMBER BRACING TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS (lb/size) 2=823/0-8-0 (min. 0-1-8), 13=267/0-8-0 (min. 0-1-8), 8=882/0-8-0 (min. 0-1-8) Max Horz 2=121(LC 6) Max Uplift 2=-712(LC 8), 13=-205(LC 8), 8=-757(LC 8) Max Grav 2=977(LC 2). 13=351(LC 19). 8=1048(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2024/1307, 3-1 6=-2314/1627,/16-17=-2314/1627, 4-17=-2314/1627, 4-5=-2314/1627, 5-6=-2314/1627, 6-18=-2314/1627; 18-19=-2314/16'27, 7-19=-2314/1627, 7-8=-2288/1477 BOT CHORD 2-15=-1106/1837, 14-15=-1103/1838, 13-14=-1103/1838, 12-13=-1427/2314, 11-12=-1269/2096,10-11=-1269/2096,8-10=-1268/2087 WEBS 3-13=-387/829, 4-13=-462/352, 6-12=-254/217, 7-12=-1791405, 7-10=-20/296 PLATES GRIP MT20 244/190 Weight: 142 lb FT = 0% Structural wood sheathing directly applied. Rigid ceiling directly applied or 5-9-3 oc bracing MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpl=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) The solid section of the plate is required to be placed over the splice line at joint(s) 11. 5) Plate(s) at joint(s) 11 checked for a plus or minus 5 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load oonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 712 lb uplift at joint 2, 205 lb uplift at joint 13 and 757 lb uplift at joint 8. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard WARNING-lerrfrda,fgn Paramem. aad READ NOTES ON 774ZSAM7 RXIODED Mr7EKREFEREACE PAGE 1411-7473.. J1291Z0I486OAEN3E Design valid for use only Wth Mfrek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPl1 Quality Cdteda, DSB-89 and BCSI Building Component Safety Information gqvauuable from Truss Plate Institute. 781 N. Lee Street, Suite 312, Alexandria, VA 2314. Rautherne-tnerSPplumber isspedfied, the design values are those effective 06 0112013byAfSC FL Cert. 6634 June 30,2014 MiTek' 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type City Ply Elev D T6397325 mi 1324 A7 HIP 1 1 [O'Carlton Job Reference o do al Chambers Truss Inc., Fort Pierce FI. 34982 r.3ou s bep zi 2uiz mi i eK industries, inc. man jun ou ii:ia:io Zuta rage i ID: _kfiGCA6bx7j2Sy1 HDXFw7ye3KX-CagCUWKg6Daguf?isnhfu6BibZL9U5FiJO?m1 Vz17G9 10 7-0-0 14-0-9 20-11-7 28-0-0 35-0-0 6-0 -0-0 7-0-9 6-4-13 7-0-9 7-0-0 -0-0 4.00 12 4x6 3x4 = 4x6 = 3x8 = 3 16 17 4 5 ° 18 19 4x6 Scale = 1:60.3 4x4 = i5 14 13 12 11 10 44. _ 3x4 = 5x6 WB = 3x4 = 2x3 11 5x6 WB — 3x4 = 7-0-0 14-0-9 20-11-7 28-M 35-0-0 7-0-0 7-0-9 6-10-13 7-0-9 7-0-0 Plate Offsets (X Y)• [2:0-3-14 Edgel 1570-3-0 Edgy 18.0-3-14 Edoel LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase - 1.25 TC 0.45 Vert(LL) 0.64 12-13 >646 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.59 Vert(TL) -0.88 12-13 >467 240 BCLL 0.0 Rep Stress Incr YES WB 0.46 Horz(TL) 0.18 8 n/a n/a BCDL 5.0 Code FBC2010ITP12007 (Matrix) Weight: 154lb FT=O% LUMBER BRACING TOP CHORD 2x4 SP M 30 TOP CHORD - Structural wood sheathing directly applied or 3-5-13 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-8-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 4-15, 6-10 OTHERS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation vide. REACTIONS (lb/size) 2=986/0-8-0 (min. 0-1-8), 8=986/0-8-0 (min. 0-1-8) Max Horz 2=97(LC 7) Max Uplift 2=-837(LC 8), 8=-837(LC 8) Max Grav 2=1171(LC 2), 8=1171(LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2757/1784, 3-16=-2576/1756, 16-17=-2576/1756, 4-17=-2576/1756, 4-5=-3885/2640, 5-6=-3885/2640, 6-18=-2576/1755, 18-19=2576/1755, 7-19=-2576/1755, 7-8=2757/1784 BOT CHORD 2-15=-1577/2542, 14-15=-2478/3885, 13-14=-2478/3885, 12-13=-2479/3885, 11-12=-2479/3885, 10-11=-2479/3885, 8-10=-157712542 WEBS 3-15=-274/563, 4-15=-14961935, 6-1 0=-1 496/936, 7-10=-274/563 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) The solid section of the plate is required to be placed over the splice line at joint(s) 14, 11. 5) Plate(s) at joint(s) 14 and 11 checked for a plus or minus 3 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 837 lb uplift at joint 2 and 837 lb uplift at joint 8. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard ♦. 00I N V, vim. •.��G•ENS�.• e * : N 68182 T OF 44/ s�•..<` C? NA� 1E�♦♦♦♦ FL Cert. 6634 June 30,2014 A wARMAG -1 edfr design Parameters and READ A07ES GN 7NISAND INCLUDED MITEKREFEREN-- PAGE MII-7413 .. 112912014DIFDAEUSE ■■■■• Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPIt Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informatlon gvaUable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA�2314. Tampa, FL 33610-4115 1f5authemPinelSF9lurnberisspecified, the design values are thaseeffective 05 01/2013hyALSC Job Truss Truss Type Qty Ply Elev DT6391326 L'canton ml 1324 A COMMON 8 1b Reference (optional Chambers Truss Inc., Fort Pierce FI. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Mon Jun 30 11:19:12 2014 Page 1 ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-KpRie8HJ3_4EQEhwdxdEG00ky?ZYH?70n1Zukzl7GD i. 1-0-0 B-4-0 12-11-0 17 6-0 22-1-0 26 8-0 35-0-0 6-0 -0-0 8-4-0 4-7-0 4-7-0 4-7-0 4-71 8-4-0 -0-0 �1 d 4.00 12 4x4 = Scale = 1:59.3 3x6 4 17 ' 15 _. 14 •- 12 3x6 2x3 II 4x6 = 3x6 = 2x3 II US = 4x6 = 8-4-0 12-11-0 22-1-0 i 26-8-0 35-0-0 8-4-0 4-7-0 9-2-0 4-7- 8�-0 Plate Offsets (X.Y)' (2.0-3-14 0-1-888j 110:0-3-14 0-1-81 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.57 Vert(LL) 0.30 14-15 >999 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.51 Vert(TL) -0.61 14-15 >676 240 BCLL 0.0 Rep Stress Incr YES WB 0.48 Horz(TL) 0.13 10 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix) Weight: 166 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-5-6 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-1-3 oc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=107910-8-0 (min. 0-1-8), 10=107910-8-0 (min. 0-1-8) Max Horz 2=223(1_C 6) Max Uplift 2=-787(LC 8), 10=-787(LC 8) Max Grav 2=1221(LC 2), 10=1221(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=2851/1613, 3-4=-2350/1342, 4-5=-2322/1353, 5-18=-2344/1412, 6-18=-2293/1436, 6-19=-2293/1436, 7-19=-2344/1412, 7-8=-2322/1353, 8-9=-2350/1342, 9-10=2851/1613 BOT CHORD 2-17=1408/2666, 16-17=-1408/2666, 15-16=-1408/2666, 15-20=-753/1731, 20-21=-753/1731, 14-21=-753/1731, 13-14=1408/2627,12-13=-1408/2627, 10-12=-1408/2627 WEBS 6-14=-455/854, 7-14=-253/174, 9-14=-552/440, 6-15=-455/854, 5-15=-253/174, 3-15=-551/440 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 8=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) 100.0Ib AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 5.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 787 lb uplift at joint 2 and 787 lb uplift at joint 10. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard I WARNTi,G -Verify design pareme Mrs and READ AU TES ON 7141SAND INCLUDED MITEKREFEREM10E PAGE M77-7473 rea V291ZOM BEFOREUSE Design valid for use only vAth MiTek connectors. This design is based only upon parametersshown, and is for an Individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer -not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component Safety Information 4vai able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. liSvuthet7iErin F lumberissaecified,thedesienvaluesarethoseeffective06.01f2013hvALSC FL Cert. 6634 June 30,2014 MiTek' 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Elev D �70'Carlton T6391327 m11324 B COMMON 3 1 Job Referenceo 'o al Chambers Truss Inc., Fort Pierce FI. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Mon Jun 30 11:19:17 2014 Page 1 ' I D:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-hmEbhsLStWii W W7ZuPU DuQJjwWzmADeJsX2lKaxz17G8 1-0-0 6-11-0 13-10-0 1-0-0 6-11-0 6-11-0 Scale: 1/2"=1' 4x5 = F 3x4 = 2X3 II 3x4 = LOADING (pso SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.31 Vert(LL) -0.04 4-5 >999 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.22 Vert(TL) -0.09 4-5 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(TL) 0.01 4 n/a n/a BCDL 5.0 Code FBC20101TPI2007 (Matrix) Weight: 47 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS (lb/size) 4=353/0-8-0 (min. 0-1-8), 2=41710-8-0 (min. 0-1-8) Max Horz 2=93(LC 7) Max Uplift 4=-275(LC 8), 2=-391(LC 8) Max Grav 4=418(LC 2), 2=497(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-771/473, 3-4=-769/470 BOT CHORD 2-5=-370/673, 4-5=-370/673 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 275 lb uplift at joint 4 and 391 lb uplift at joint 2. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard ® WARNTNG - Verity design parame [ers and READ NO 7ES ON 71,1ISAND INCLUDED NITER REEEREXE PAGE NII-7473 re. 1/29/201d BDUZE'USE Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members any. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage. delivery, erection and bracing, consult ANSI/TPIT Quality Criteria, DSB-89 and BCSI Building Component Sofey Information va' able from Truss Plate Institute, 781 N. Lee Street Suite 312, Alexandria, VA 222314. ifnuthernPhia(SF)Iumbarizspetified,thadesignvaluesarethoseeffer, Ive05/01/2013byALSC ,,♦ ``yak) I N ♦ V I� i * : N 68182 0�44/` e,��,,,s FL Cert. 6634 June 30,2014 MiTek' 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Elev DT6391328 E'cadton ml 1324 BH7 BOSTON HIP 1 1b Reference (optional Chambers Truss Inc., Fort Pierce FI. 34982 /.sou s sep zi zulz mi i ex inausines, inc. noon uun su ii:iv:in zui4 rage i I D:_kfiGCA6bx7j2Sy1 HDXFw7ye3 KX-d9ML6YNiP8yEmJjGXvFMVkpFOm01hWM9?MERegz17136 1-0 6-9-4 11-6-0 13-" 15-0-0 17-6-0 .19-6-1 21-6-1 23-0-1 28-2-12 35-0-0 6-0 -0-0 6-9-4 4-112 2-0-0 2-0-0 2-0-0 2-0-1 2-0-0 2-0-0 4-8-11 6-9-4 -0-0 Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified Building Designer as per ANSI/TPI 1. 4.00 FIT 4x5 = 4x4 = 13 15 5x12 10 3x6 5:� 8 17 5x12 US 7 7A6 WB— 19 4 5 21 22 3 �s 3x4 = 3x6 = US = 3x6 = 3x4 = Scale = 1:62.3 A 24 A 25 o d 4x4 = 17-6-0 _ 35-0-0 17-0-0 17-M Plate Offsets (X Y)• (270-3-14 Edge] r14.0-2-80-3-81. f24:0-3-14 Edgej LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.35 Vert(LL) 0.28 28 >999 360 MT20 2441190 TCDL 7.0 Lumber Increase 1.25 BC 0.47 Vert(TL) -0.41 26-28 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.25 Horz(TL) 0.13 24 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 197 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-9-8 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 4-28, 22-28 JOINTS 1 Brace at Jt(s): 12, 9, 16 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=986/0-8-0 (min. 0-1-8), 24=986/0-8-0 (min. 0-1-8) Max Horz 2=223(LC 7). Max Uplift 2=837(LC 8), 24=837(LC 8) Max Grav 2=1171(LC 2), 24=1171(LC 2) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=2742/1807, 3-4=-2536/1716, 4-5=-1462/1022, 5-7=1430/1026, 7-8=-1431/1041, 8-1 0=1 416/1063, 10-13=-1408/1098, 13-15=-1408/1098, 15-17=1416/1063, 17-19=-1431/1041,19-21=-1430/1026,21-22=-1462/1022,22-23=-2536/1716, 23-24=-2742/1807, 4-6=-636/392, 6-9=-639/396, 9-11=-639/396, 11-12=-639/396, 12-14=-639/396, 14-16=639/396, 16=18=639/396, 18-20=-639/396, 20-22=636/392 BOT CHORD 2-30=1603/2532, 29-30=-1436/2359, 28-29=1436/2359, 27-28=-1436/2359, 26-27=-143612359,24-26=-1603/2532 WEBS 4-30=-93/307, 22-26=-93/307, 4-28=-548/347, 12-28=-208/421, 22-28=-548/347, 12-13=-475/649 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.1B; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 837 lb uplift at joint 2 and 837 lb uplift at joint 24. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard ®WARNING -Verity design pa ,.W s and READ N37ES ON 7WSAND INCLUDED NITEKREFEREAkX PAGE NII-7473 rex 11291Z074BLF!MU5E Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction Is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Crlteda, DSB-89 and BCSI Building Component Safety Information gvai able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. If Sauthera P'me 1513 lumber is specified, the design values are those effective 06/0112013 byALSC `11111111f11111 %��`� Qv 1 N ;% .•�.%C•ENSF•. '0. i ♦ Nic 68182 .o T F 00 Ito 0 FL Cert. 6634 June 30,2014 MiTek' 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type City Ply 70' Cadton Elev D T6391329 mi 1324 GRA SPECIAL 1 1 Job Reference (optional Chambers Truss Inc., Fort Pierce FI. 34982 f.3ou s Sep zf zuiz mi i eK maustnes, Inc. noon uun su i i:ta:iy zu14 rage t I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-d9ML6YNiP8yEmJjGXvFMVkpHZmRAhZG9?MERegz17G6 1-0-0 4-1-8 5-7-3 8-2-13 9-8 8 13-10-0 14-10-0 1-0-0 4-1-8 1-5-11 2-7-9 15-11 4-1-8 1.0-0 Scale=1:26.6 2.37 12 5x6 = 5x6 = 4x4 4x4 13 4 14 15 5 16 6 3x5 = 2x3 II 2x3 II 2x3 II 2x3 II 3x5 = 4-1-8 5-7-3 8-2-13 9-8-8 13-10-0 1 4-1-8 15-11 2-7-9 15-11 4-1-8 Plate Offsets (X Y)• [2.0-2-8 Edgel 17:0-2-8 Edge) LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ltd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.21 Vert(LL) 0.10 11 >999 360 MT20 244/190 _! TCDL 7.0 Lumber Increase 1.25 BC 0.32 Vert(TL) -0.12 10-11 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.06 Horz(TL) 0.03 7 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 53 lb FT;= 0% LUMBER BRACING . TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-4-11 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-11-9 oc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=684/0-8-0 (min. 0-1-8), 7=684/0-8-0 (min. 0-1-8) Max Horz 2=53(LC 7) Max Uplift 2=-615(LC 8), 7=-615(LC 8) Max Grav 2=814(LC 19), 7=814(LC 20) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1795/1223, 3-13=1702/1206, 4-13=-1679/1188, 4-14=-1657/1171, 14-15=-1657/1171, 5-15=-1657/1171, 5-16=-167911187, 6-16=-1702/1202, 6-7=1795/1224 BOT CHORD 2-12=1104/1646, 12-17=-1104/1655, 11-17=110411655, 10-11=-1098/1657, 10-18=-1103/1655,9-18=-1103/1655,7-9=-1102/1646 NOTES 1) Unbalanced roof live loads have been considered for this design. ,`P// N /"., 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. QU I �/� 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. ,`%� ,� O`•. • • •"• • • • �� I* � , •�\Ci E N S'�•, 10.0 bottom live load live loads. 4) This truss has been designed for a psf chord nonconcurrent with any other 5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide N 6818 will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 615 Ib uplift at joint 2 and 615 lb uplift at joint 7. 7) 'Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 79 lb down and 102 lb up at T 0 F C(/ �• �(/ 4-1-8, 111 lb down and 136 lb up at 5-0-0, 132 lb down and 158 lb up at 5-7-3, 61 lb down and 129 lb up at 5-11-0, 61 lb down and 129 lb up at 7-11-0, 132 lb down and 158 lb up at 8-2-13, and 111 lb down and 136 Ib up at 8-10-0, and 79 lb down and 116 lb up (� .; �j '.'C Q;•' �� 34 lb down 4-1-8, 45 lb down 5-0-0, 54 lb down 5-7-3, 38 lb down 5-11-0, 38 lb down at �j� '• •' at 9-8-8 on top chord, and at at at at s • • `G\,�� lb downand45lb down at -10-0, and 34 lb down at 9-8-8 on bottom chord. The design/selection of such at2-13,he I /S N q' %% connection ( is t responsibility of others, /O 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 FL Cert. 6634 June 30,2014 ®WARKAG - Verify design parame cars and READ NOTES ON 7WSAND fKaUDED NfTEXREFEREAC E PAGE Nrr-7473. r. 1/2912014BEFORE715E ■■■ Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the lilt iTek° erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Sale ty Inlormaflon vat able from Truss Plate Institute, 781 N. Lee Street, Suite 312; Alexandria, VA 2314. Tampa, FL 33610-4115 li5authemMne(SP�Iumberisspecified,thedes-ignvaluesarethoseeffective06 0112013byALSL' Job Truss Truss Type Qty Ply 70' Carlton Elev D T6391329 ml 1324 GRA SPECIAL 1 1 Job Reference (optional Chambers Truss Inc., Fort Pierce FI. 34982 r.aou s bep zi zuiz mi i eK mausmes, inc. mon dun au i is-ia:iu zu i9 rage z ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-d9ML6YNiP8yEmJjGXvFMVkpHZmRAhZG9?MERegz17G6 LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-3=-44, 3-4=44, 4-5=44, 5-6=-44, 6-8=-44, 2-7=10 Concentrated Loads (Ib) Vert: 3=-31(B) 4=-75(B) 5=-75(B) 6=-31(B) 12=9(B) 11=-31(B) 10=-31(B) 9=-9(B) 13=-58(B) 14=-49(8) 15=-49(B) 16=-58(8) 17=-15(B) 18=-15(B) LYYARAFFM - Verffr design parame rers and il&U MTE5 ON 7NISAM7 Ir aUDED MITEK REFERE&CE PAGE Mlr-7473 re r, i/29/201481FOAEUSE Design valid for use only with Mirek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding M1Tek• fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information vai able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. Tampa, FL 33610.4115 It 5auth ern Pine�SF� lumb er is speed, the design values are those effettive v6 101 f 20131Ty'Atsc Job Truss Truss Type Qty Ply Elev DT6391330 E'Carlton ml 1324 GRB SPECIAL 1 1b Reference (optional Chambers Truss Inc., Fort Pierce FI. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Mon Jun 30 11:19:20 2014 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-5LwjJuNLAR45NTIT5cmb2yLQbAiMQwUI EOz_AGz17G5 1-0 5-0-0 10-3-14 15-0-0 21-6-0 26-2-0 28-1-0 35-0-0 6-0 -0-0 5-3-14 5-2-2 6-0-0 4-8-0 1-11-0 6-11-0 0-0 Scale = 1:62.4 4x4 = 4.00 12 4x4 3x6 = 2x3 II 2x3 I 4x4 3x4 = 9 18 19 4 20 21 5 622 23 24 725 26 27 8 I3 I 10 I 3x5 = 17 28 29 30 16 31 1 3233 34 14 3513 12 3x4 = 3x4 = 46 = 5> _ 3x4 =UB = 3x4 = 5-0-0 15-6-0 21 8-0 28-1-0 35-0-0 5-0-0 10-6-0 6-0-0 6-7-0 6-11-0 Plate Offsets (X Y)• 12:0-2-8 Edgel LOADING (psf) SPACING 2-0-0 CSI DEFIL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.38 Vert(LL) -0.33 15-17 >544 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.64 Vert(TL) -0.61 15-17 >299 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.45 Horz(TL) 0.03 10 n/a n/a BCDL 5.0 Code FBC201 o/TP12007 (Matrix) Weight: 144 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-5-12 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 4-15 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 0-8-0. (lb) - Max Harz 2=83(LC 7) Max Uplift All uplift 100 lb or less atjoint(s) except 2=-592(LC 8), 15=-830(LC 8), 14=-565(LC 8), 10=-331(LC 8) Max Grav All reactions 250 lb or less at joints) except 2=760(LC 19), 15=1213(LC 2), 14=797(LC 2), 10=413(LC 14) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1677/1084, 3-18=-1540/1050, 18-19=-1539/1050, 4-19=-1539/1050, 4-20=-313/525, 20-21=-313/525, 5-21=-313/525; 5-22=-313/525, 6-22=313/525, 6-23=-313/525, 23-24=-313/525, 24-25=-313/525, 7-25=-313/525, 7-26=313/525, 26-27=-313/525, 8-27=-313/525, 8-9=580/297, 9-10=-616/273 BOT CHORD 2-17=-937/1535, 17-28=-912/1201, 28-29=-912/1201, 29-30=-912/1201, 16-30=-912/1201, 16-31=912/1201, 31-32=-912/1201, 15-32=-912/1201, 15-33=-525/437, 33-34=-525/437, 34-35=-525/437,14-35=-525/437,13-14=-114/546,12-13=-114/546,10-12=-153/528 WEBS 3-17=0/299, 4-17=-59/611, 4-15=-1790/1402, 6-15=-496/476, 7-14=-433/409, 8-14=890/586 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 592 lb uplift at joint 2, 830 lb uplift at joint 15, 565 lb uplift at joint 14 and 331 lb uplift at joint 10. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. EkWARMNG-Verrfrdesign parameters and READ NOTESOMTNISAND INl7.UDED MITEKREFEREACE PAGE MII-7473 rez I/291ZOI66EFOAELSE Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component Safety Information 7vailable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. 1f5outhernPine SIX lumber issoar1fied, the design vatiaesare those effective 06 01f2013.myALSC FL CerL 6634 June 30,2014 MiTek' 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Carlton Elev D [0' T6391330 ml 1324 GRB SPECIAL 1 1 b Reference (optional Chambers Truss Inc., port Fierce 1•I. 34tla-1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-5Lw4JuNLAR45NTIT5cmb2yLQbAiMQwUIEOz_AGz17G5 NOTES 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 289 Ib down and 353 Ib up at 5-0-0, 101 Ib down and 129 Ib up at 7-0-12, 101 Ib down and 129 Ib up at 9-0-12, 101 Ib down and 129 Ib up at 11-0-12, 101 Ib down and 129 Ib up at 13-0-12, 101 Ib down and 129 Ib up at 15-0-12, 101 Ib down and 129 Ib up at 17-0-12, and 101 Ib down and 129 Ib up at 19-0-12, and 101 Ib down and 129 Ib up at 21-1-4 on top chord, and 112 Ib down at 5-0-0, 38 Ib down at 7-0-12, 38 Ib down at 9-0-12, 38 Ib down at 11-0-12, 38 Ib down at 13-0-12, 38 Ib down at 15-0-12, 38 Ib down at 17-0-12, and 38 Ib down at 19-0-12, and 38 Ib down at 21-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=44, 3-8=-44, 8-9=-44, 9-11=44, 2-10=-10 Concentrated Loads (lb) Vert: 3=-170(F) 5=49(F) 17=42(F) 18=-49(F) 19=49(F) 20=-49(F) 22=-49(F) 23=-49(F) 24=-49(F) 25=-49(F) 28=-13(F) 29=-13(F) 30=13(F) 31=-13(F) 32=13(F) 33=-13(F) 34=-13(F) 35=-13(F) A WARNING-Vedfrdeiign parameters and READ NOTESON RFISAND IMMMED MITEKREFEREPKE PAGEMII-1473.. 1129120I4BEFOMVM Design valid for use only with Mirek connectors. This design Is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MiTek' .erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPIT Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information vai able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. 1f5auth- nP"in P Iumbelisspecified,thedesiantfaluesarethoseeffettiveR6 41f2013hy041SC Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply 70' cadton Elev D T6391331 m11324 GRC HIP 1 1 Job Reference (optional Chambers Truss Inc., Fort Pierce FI. 34982 1.350 s Sep 27 2012 MiTek Industries, Inc. Mon Jun 30 11:19:21 2014 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-ZXU5XDOzxlCy?cffeKHgb9uSga2B9IaSSgjXj zl7G4 1-0 7-0-0 13-8-0 20-9-10 28-0-0 35-0-0 16- q OD0 7-0.0 6-8-0 7-1-10 7-2.6 7-0-0 -0-0 This truss is NOT symmetric. Proper orientation is essential. 4.00 12 5x8 = 3x6 I 5x6 WB = 5x8 = 5x10 3 16 17 18 19 4 20 5 21 22 6 23 24 25 26 7 Scale = 1:60.3 3x4 = 15 27 , 28 14 29 13 30 31 32 33 12 34 11 35 36 10 3x6 2x3 II 3x6 = 6x10 = 3x4 = 4x6 = 2x3 I 7-0-0 13-B-0 20-9-10 28-0-0 35-0-0 7-0-0 6-8-0 7-1-10 7-2-0 7-0-0 Plate Offsets (X Y)7 [3.0-5-12 0-2-12], [5.0-3-0 Edged r6.0-3-80-2-8], [770-5-0 0-2-0] [8.0-3-14 0-1-8] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.94 Vert(LL) 0.26 10-12 >965 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.60 Vert(TL) -0.38 10-12 >669 240 BCLL 0.0 Rep Stress Incr NO WB 0.71 Horz(TL) 0.10 8 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix) Weight: 155 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP M 30 TOP CHORD . Structural wood sheathing directly applied or 3-9-3 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-3-9 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpt 3-13, 6-13 4-13: 2x6 SP No.2, 6-13: 2x4 SP M 30 MiTek recommends that Stabilizers and required cross bracing OTHERS 2x4 SP No.3 be installed during truss erection, in accordance with Stabilizer [Installation guide. REACTIONS (lb/size) 2=445/0-8-0 (min. 0-1-8), 13=2650/0-8-0 (min. 0-3-11), 8=103710-8-0 (min. 0-1-8) Max Horz 2=84(LC 7) Max Uplift 2=-430(LC 8), 13=-2294(LC 8), 8=-942(LC 8) Max Grav 2=539(LC 19), 13=3139(LC 2), 8=1234(LC 20) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-869/566, 3-16=-1085/1586, 16-17=-1085/1587, 17-18=-1085/1587, 18-19=1085/1587, 4-19=-1085/1587, 4-20=-1085/1587, 5-20=-1085/1587, 5-21 =1 085/1587, 21-22=-1085/1587, 6-22=-1085/1587, 6-23=-2144/1634, 23-24=-2144/1634, 24-25=-2144/1634, 25-26=-2144/1634, 7-26=-2144/1634, 7-8=-2967/2109 BOT CHORD 2-15=-458/764, 15-27=-467/793, 27-28=467/793, 14-28=-467/793, 14-29=-467/793, 13-29=-467/793, 13-30=-1473/2144, 30-31 =1 473/2144, 31-32=-1473/2144, 32-33=-1473/2144, 12-33=-1473/2144, 12-34=-1898/2774, 11-34=-1898/2774, 11-35=-1898/2774, 35-36=-1898/2774, 10-36=-189812774, 8-10=-1887/2743 WEBS 3-15=-1711559, 3-13=-2501/1791, 4-13=-893/863, 6-13=-3917/2865, 6-12=-25/611, ,••.��Ci•E•NS'�• ��' 7-12=-670/448, 7-1 0=-1 81/595 �� NOTES `,� N 68182 • * �� •; 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuit=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 13 r7 3) Provide adequate drainage to prevent water ponding. i T F •• 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide 0Q 0 Q 0i •'•\• �� will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 430 lb uplift at joint 2, 2294 lb uplift at III joint 13 and 942 lb uplift at joint 8. "Semi /j/ 7) -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.is FL Cert. 6634 June 30,2014 ®WARNING-Vedfrdasign paremeters and READ M7ESON TNESAM lKaUDED MTTEXREFERENC E PAGEM11-7473 rex V291201/BfFOAEUSE ■■■■ Design valid for use only with Mfrek connectors. This design is based only upon parameters shown, and is for an individual building component.�� Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown . Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibilllty of the MiTek' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information cc��va' able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. Tampa, FL 33610-4115 1iSautheraPinelSP�Iumber isspecified,thedesign valuesarethoseetfective05 01/2o13byALSC Job Truss Truss Type Qty Ply 70' cariton Elev D T6391331 m11324 GRC HIP 1 1 Job Reference (optional) Chambers Truss Inc., Fort Pierce Ff. 34982 7.3bu s Sep 212012 MITek Inaustnes, Inc. Mon Jun 30 11:19:21 2014 F age z ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-ZXU5XDOzxICy?cffeKHgb9uSga2B91aSSgjXjjz17G4 NOTES 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 231 lb down and 352 lb up at 7-0-0, 118 lb down and 189 lb up at 9-0-12. 118 lb down and 189 lb up at 11-0-12, 118 lb down and 189 lb up at 13-0-12, 118 lb down and 189 lb up at 15-0-12, 118 lb down and 189 lb up at 17-0-12, 118 lb down and 189 lb up at 17-11-4, 118 lb down and 189 lb up at 19-11-4, 118 lb down and 189 lb up at 21-11-4. 118 lb down and 189 lb up at 23-11-4, and 118 lb down and 189 lb up at 25-11-4, and 231 lb down and 352 lb up at 28-0-0 on top chord, and 388 lb down and 240 lb up at 7-0-0, 68 lb down at 9-0-12, 68 lb down at 11-0-12, 68 lb down at 13-0-12, 68 lb down at 15-0-12, 68 lb down at 17-0-12, 68 lb down at 17-11-4, 68 lb down at 19-11-4, 68 lb down at 21-11-4, 68 lb down at 23-11-4, and 68 lb down at 25-11-4, and 388 lb down and 240 lb up at 27-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B), LOAD CASE(S) Standard 1) Regular: Lumber Increase=1:25, Plate Increase=1.25 Uniform Loads (plo Vert: 1-3=-44, 3-7=-44, 7-9=-44, 2-8=-10 Concentrated Loads (lb) Vert:3=-156(B) 5=-96(B) 7=-156(13) 15=-333(B) 10=-333(B) 16=-96(B) 17=-96(B) 19=-96(B) 20=-96(B) 21=-96(B) 22=-96(B) 23=-96(B) 25=-96(B) 26=-96(B) 27=-23(B) 28=-23(B) 29=-23(B) 30=-23(B) 31=-23(B) 32=-23(B) 33=-23(B) 34=-23(B) 35=-23(B) 36=-23(B) ,&WARN M - Vedfr design parama Wrs and READ M+TES DN 714ISAND INCLUDED NITEK REFEREM10E PAGE NII-7473 .. t/2912014BDFOAEVM Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. �e Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the iVliTe k' erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information vai able from Truss Plate Institute. 781 N. Lee Street Suite 312, Alexandria, VA 2314. Tampa, Fl- 33610-4115 1iSauthernFine�S.p lumber issirecified, the design values are thoseeffertive0'6 01/2013byALS Job Truss Truss Type Qty Ply Elev o E'Carltcm T6391332 ml 1324 11 MONO TRUSS 6 1b Reference (optional chambers T russ Inc., t-on Tierce ri. m9ts2 r.00" s aep a 4U 14 -1- Ill. m1 s, mo. niun -1. - - rnz4 4v w I.Y. . ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-1k2UkZPbi3LpdmSrC1o37NQq8_XeuwybhK85F9z17G3 . r -1-0-0 1-0-0 _ J 1-0-0 1-0-0 Refer to MiTek "TOE -NAIL" Detail for connection to Scale =1:6.1 supporting carrier truss (typ all applicable jacks on this job) 3 4.00 12 2 r—' d N 1 O 3x4 = LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ltd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.12 Vert(LL) -0.00 2 >999 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.01 Vert(TL) -0.00 2 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix) Weight: 5 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation ouide. REACTIONS (lb/size) 2=99/0-8-0 (min. 0-1-8), 4=5/Mechanical, 3=-7/Mechanical Max Horz 2=47(LC 8) Max Uplift 2=-153(LC 8), 3=-8(LC 2) Max Grav 2=120(LC 2), 4=14(LC 3), 3=26(LC 8) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. Il; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 2 and 8 lb uplift at joint 3. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard AWARM&ti -V.df y design parama mrs and READ M.I TES ONTNISAND INO.UDED MITEKREFERE&IM PAGE MII-7473 re a I/29/20140EFMEWE Design valid for use only with Wek connectors. This design is based only upon parameters shown, and 1s for an Individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage. delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component Safety Information �vapable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. IiSauthemPine SPPPlumberisspecifred,thedesignvaluesarethoseeffective0 01/201-1byAISC %%���ptU I N ;vim .•�,�0•E N 0- i N 68182 T OF FL Cert. 6634 June 30,2014 my 21e MiTek' 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply �70'CarltonElev,D T6391333 m11324 J3 MONO TRUSS 6 1 ob Reference (optional) Chambers Truss Inc., Fort Pierce FI. 349152 1-0-0 3x4 = I.JaU JoeP trio will — mwsnro>, nu:. „u'l" II.,v—Lu'" goy.1 I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-1 k2UkZPbi3LpdmSrC 1 o37NQp8_WHuwybhKS5F9zl7G3 Scale = 1:9.4 LOADING (psf) SPACING 2-0-0 CSI DEFIL in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.19 Vert(LL) -O.Ob 2-4 >999 360 MT20 2441190 TCDL 7.0 Lumber Increase 1.25 BC 0.10 Vert(TL) -0.01 2-4 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 11 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=43/Mechanical, 2=144/0-8-0 (min. 0-1-8), 4=13/Mechanical Max Horz 2=84(LC 8) Max. Uplift 3=-47(LC 8), 2=-178(LC 8) Max Grav 3=61(LC 13), 2=174(LC 2), 4=39(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by other's) of truss to bearing plate capable of withstanding 47 lb uplift at joint 3 and 178 lb uplift at joint 2. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ``Qv I N ,� OP` �� ♦� , E N SF.• ��' LOAD CASE(S) Standard `,�� ,•�\Ci *: N 68182 ;• 14J . T OF .� 10••.• N '�� S ����• � N A1- FL Cert. 6634 June 30,2014 AWARNT&G-Verifydesign paramea=rs and READ ACITES ON TNISAND INO11DED MITEKREFEREhCE PAGEMII-7473.z 112912014BEFOREME Design valid for use only with Mirek connectors. This design is based only upon parameters shown, and is for an individual building component. Not of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responslbillity, of the MiTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information 4vauable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. Tampa, FL 33610.4115 ifSauthemlline1SIR lumber isspec"died,thedesign values are thuseeffective0fi 0111013byALSC Job Truss Truss Type Qty Ply Elev DT6391334 L'cadton ml 1324 J5 MONO TRUSS 15 1b Reference (optional Chambers Truss Inc., Fort PlerCe H. 34962 1-0-0 3x4 = ! AJu 5 aep LI LU I L MI eK IOuu SlflBS, Inu. Nlun Jun au I I: ­4Z N 14 rage I ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-1 k2UkZPbi3LpdmSrC 1 o37NQkS_SbuwybhKS5F9zl7G3 Scale = 1:12.7 5-0-0 5-0-0 - - - -- --' LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.49 Vert(LL) -0.03 2-4 >999 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 SC 0.33 Vert(TL) -0.05 2-4 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 17 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=93/Mechanical, 2=192/0-8-0 (min. 0-1-8), 4=23/Mechanical Max Horz 2=122(LC 8) Max Uplift 3=-114(LC 8), 2=-202(LC 8) Max Grav 3=127(LC 13), 2=230(LC 2). 4=69(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) ro 2 e mechanical connection (by others) of truss to bearing plate capable of withstanding 114 Ito uplift at joint 3 and 202 lb uplift at ``,�QU 1 N ��t����',, 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ,�� OP•. • • "' • � �i� LOAD CASE(S) Standard , '•�'\C E N S�• '� 40 1. N 68182 aT OF :•�' 00 % AWO""" till I FL Cert. 6634 June 30,2014 Ao,wvipmm-Verirrdesign paramerEra and READ AOTESON THISAND INaLMED Mr EKREFEREKE PAGEMrf-7473..I/29/7014BFFOREUSE ■�■■� Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MiTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610-4115 ifSauffiemP-mL SP lumber is specified, the design values are those effective 06i0112013byALSC Job Truss Truss Type Qty 7O' Carlton Elev D ]Ply T6391335 mi 1324 J7 MONO TRUSS 12 1 Job Reference (optional Chambers Truss Inc., Fort Pierce FI. 34982 - r.aau s pep zr zurz rvn I eK mausmes, inc. mon dun au i i s-ia:za zu i9 rage i ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-VwbsyvQDTMTgEwl2mlKlga7x3NigdMCkw Cenbzl7G2 1-0-0 7-0-0 — 1-0-0 7-0-0 Scale: 3/4"=V 3x4 = 7-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.37 Vert(LL) -0.12 2-4 >639 360 MT20 2441190 TCDL 7.0 Lumber Increase 1.25 BC 0.73 Vert(TL) -0.22 2-4 >365 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 23lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=140/Mechanical, 2=243/0-8-0 (min. 0-1-8), 4=33/Mechanical Max Horz 2=160(LC 8) Max Uplift 3=-174(LC 8), 2=-234(LC 8) Max Grav 3=189(LC 13), 2=291(LC 2), 4=99(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 174 lb uplift at joint 3 and 234 lb uplift at joint 2. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard (EL WAR--frd-gaPardmem-and AFRO M?FSON 11,11SANOrNaUDE0 Nr7EXREFEREWIF PAGEN71-7473 rez 11291Z0I4BRiWLiM Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TP11 Quality Criteria,DSB-89 and-BCSI Building Component Safety Information qva able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, Vq 2314. IfSauthernPine �SF ILLmberissoeCfed. thedesiEnvaluesaretheseeffect:ive0fi 0112013bvALSC FL Cert. 6634 June 30,2014 MiTek* 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Elev D �70'Carlton T6391336 m11324 JA MONO TRUSS 2 1 Job Reference (optional Chambers Truss Inc., Fort Pierce FI. 349B2 r.aou s bep zr zuiz mi i eK mausmes, inc. mon aun au r i nu:za zu w rage i ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-VwbsyvQDTMTgEwl2MIKlgaz_uNtDdMCkw Cenbz17G2 -1-0-0 2-4-3 1-0-0 2-4-3 Scale = 1:8.3 ,3x4 = 2-43 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.19 Vert(LL) -0.00 2 >999 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.05 Vert(TL) -0.00 2-4 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 9 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-4-3 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=24/Mechanical, 2=132/0-8-0 (min. 0-1-8), 4=10/Mechanical Max Harz 2=72(LC 8) Max Uplift 3=-28(LC 5). 2=175(LC 8) Max Grav 3=36(LC 13), 2=159(LC 2), 4=30(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; 13=45ft; L=50ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and' any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3 and 175 lb uplift at joint 2.I ,,,,`tQv I N I 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ........ , E S'F• ��' LOAD CASE(S) Standard ;� ,•�\G :C� N 68182 T F �. A1- �aN E�� �n1n1 FL Cert. 6634 June 30,2014 AwARNrAG- V.,frde ig.paremere...d READ AURSOM TUISAUD IAUUDED MITEKREFEREACE PAGE MII-7473 rez V29120I4BEFGREUSE ■■�■� Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual.web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the MiTek erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and brocing, consult ANSI/TPII Quality Cdteria, DSB-89 and BCSI Building Component Safety Information vcCruble from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA/2314. I}SauthernPineISPpIumberisspecified,thedesignvaluesarethoseeffective0601/2013byALSC 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type City Ply Elev D �70'Cartton T6391337 m11324 JB MONO TRUSS 2 1 ob Reference o tional Chambers Truss Inc., Fort Pierce FI. 34952 c.aau s oep zt zu-iz w i m mausmes, mc. mion dun au i i; i—a m i4 rayc i ID:_kfiGCA6bx7j28y1HDXFw7ye3KX-VwbsyvQDTMTgEwl2mlKlgaztZNnbdMCkw Cenbz17G2 -1-2-5 55-11 1-2-5 55-11 3x4 = LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud TCLL 20.0 Plates Increase 1.25 TC 0.59 Vert(LL) -0.04 2-4 >999 360 TCDL 7.0 Lumber Increase 1.25 BC 0.41 Vert(TL) -0.08 2-4 >800 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2010/rP12007 (Matrix) LUMBER TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS (lb/size) 3=102/Mechanical, 2=215/0-8-0 (min. 0-1-8), 4=26/Mechanical Max Harz 2=115(LC 8) Max Uplift 3=-119(LC 8), 2=-234(LC 8) Max Grav 3=127(LC 13), 2=258(LC 2), 4=77(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:12.7 PLATES GRIP MT20 2441190 Weight: 19 lb FT = 0% BRACING TOP CHORD Structural wood sheathing directly applied or 5-5-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) " This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 119 lb uplift at joint 3 and 234 lb uplift at joint 2. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard WARNING -Verdr derign parameters and READ N07ES ON MrSAND INCLUDED MrTEKREFEREhCF PAGE MII-7473 rer. 3129120I4BEFOREU3E Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPIT Quality Criteria, DSB-89 and BCSI Building Component Safety Information wq'aable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. ItSauthemlpinelSP�lumberisspecified,thedes'ranualuesarethaseeHective06 0112013byALSC 111111111/tI Qv IN :��♦♦ SOP G.E N i *: N 68182 �X . � T OF • C? FL Cert. 6634 June 30,2014 Not MiTek' 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply Elev D [O'Cadton T6391338 m11324 JC MONO TRUSS 2 1 Job Reference (optional Chambers Truss Inc., Fort Pierce Ff. 34982 7.350 s Sep 27 2012 MITek Industnes, Inc. Mon Jun 30 11:19:23 2014 Page 1 ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-VwbsyvQDTMTgEwl2mlKlgaz?uNtgdMCkw Cenbzl7G2 1-1-4 1-0-0 1-1-4 3x4 = Scale = 1:6.2 1-1-4 1-14 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.12 Vert(LL) -0.00 2 >999 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.01 Vert(TL) -0.00 2 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2010/TPl2007 (Matrix) Weight: 5 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-1-4 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MITek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=99/0-8-0 (min. 0-1-8), 4=5/Mechanical, 3=-2/Mechanical Max Horz 2=49(LC 8) Max Uplift 2=-149(LC 8), 3=-6(LC 5) Max Grav 2=120(LC 2). 4=15(LC 3), 3=18(LC 8) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional);. Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate'capable of withstanding 149 lb uplift at joint 2 and 6 lb uplift at joint 3. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard WARNING-Vef fydesign pammetea and READ Na7ESON 7NISAND INO.IIDED MXTEKREFEREACE PAGE MIX-7473 ma 1/29/20I4BDVREU3E Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabricatlon, quality control, storage. delivery, erection and bracing, consult ANSI/TPI7 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312. Alexandria, VA 22314. IfSauthernpine SP Iurnberisspecfed',thedesignvaluesarethoseeffective05 01I2013bvALSC ,1111 Go IN , ;; , .•�,�G•E•NSF . 4#. i N 68182 % -10 •�� T OF 00O'••7c .,, 1,ss FL Cert. 6634 June 30,2014 MITek' 6904 Parke East Blvd. Tampa, FL 33610.4115 Job Truss Truss Type Qty Ply 70' Carlton Elev D T6391339 m11324 KJ5 MONO TRUSS 1 1 Job Reference (optional) Chambers Truss Inc., Fort Pierce FI. 34982 5 2 3x4 = 2.83 12 r.'sbussepztzuiYmiieKmaustnes,inc. moniunsutt:ta:z42ui4 rages ID:_kfiGCA6bx7j2Sy.1HDXFw7ye3KX-z69E9FQrEgbXs4cEKSrXCoW6hn9PMpSu6exBJ1z17G1 7-0-2 7-0-2 Scale=1:15.7 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.38 Vert(LL) -0.09 2-4 >840 360` MT20 2441190 TCDL 7.0 Lumber Increase 1.25 BC 0.25 Verl(TL) -0.16 2-4 >495 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 23 lb FT = 0% LUMBER TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 REACTIONS (lb/size) 3=164/Mechanical, 2=187/0-11-5 (min. 0-1-8), 4=40/Mechanical Max Harz 2=11 O(LC 8) Max Uplift 3=-190(LC 8), 2=-211(LC 8) Max Gray 3=211(LC 13), 2=225(LC 2), 4=106(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING TOP CHORD Structural wood sheathing directly applied or 7-0-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=loft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 190 lb uplift at joint 3 and 211 lb uplift at joint 2. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-5=-44 Trapezoidal Loads (plf) Vert: 5=0(F=22, B=22)-to-3=-77(F=-16, B=-16), 2=-1(F=5, B=5)-to-4=-18(F=-4, B=-4) ®WARNIAG -Verity design parameters and AEAD NO TES ON TNISANO INCUIDE0 NrTEKREFERENtf PAGE NII-7473 rex 1129/2014BRFGRE VSE Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown ' is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPll Quality Criteria, DSB-89 and BCSI Building Component Safety Information gvas able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. IfSauthemRff ine`SPlumberisspecified,thedesignvaluesarethoseeectiveCS 01f2flL'hyALSC FL Cert. 6634 June 30,2014 MiTek' 6904 Parke East Blvd. Tampa, FL 33610-4115 Job Truss Truss Type Qty Ply 0'Cadton Elev D T6391340 [ob m11324 KJ7 MONOTRUSS 2 1 Reference (optional Chambers Truss Inc., Fort Pierce FI. 34982 r.adu s aep zi zuiz mi i eK industries, inc. Mon dun du 1 _i:-ia:za 26 i4 rage i ID:_kfGCA6bx7j2Sy1HDXFw7ye3KX-z69E9FQrEgbXs4cEKSrXCoWBPn92MmOu8exBJ1zl7G1 1-5 O 6-8-12 9-10-1 1-5-0 6-8-12 3-1-5 Scale = 1:20.6 3x4 = 3x4 = 6-6-12 _ — 9-10-1 6-6-12 3-1-5 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.20 Vert(LL) -0.04 2-7 >999 360 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.21 Vert(TL) -0.08 2-7 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.20 Horz(TL) 0.01 5 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 38 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=104/Mechanical, 2=294/0-11-5 (min. 0-1-8), 5=310/Mechanical Max Horz 2=191(LC 8) Max Uplift 4=-130(LC 8), 2=-2BO(LC 8), 5=-232(LC 8) Max Grav 4=155(LC 13), 2=351(LC 2). 5=387(LC 13) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=703/330 BOT CHORD 2-7=-454/699, 6-7=-454/699 WEBS 3-6=-806/524 NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate, grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' has been designed for live load 20.Opsf the bottom in 3-6-0 tall by 2-0-0 wide �fI/l� 3) This truss a of on chord all areas where a rectangle ♦♦♦'"� N will fit between the bottom chord and any other members. ,♦♦ QU V •��� �I 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 130 lb uplift at joint 4, 280 lb uplift at ,♦♦ OP � , Ci•EN S'�.• joint 2 and 232 lb uplift at joint 5. �•.�� 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. N 68182 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 "4 Uniform Loads (plf) Vert: 1-8=44 i T O F 411 Z Trapezoidal Loads (plf) �j, '•'C `Q Q;•'��,�� ' Vert: 8=0(F=22, B=22)-to-4=-108(F=-32, B=-32), 2=-1 (F=5, B=5)-to-6=-25(F=7, B=-7) �I tS • , • • • ♦♦ FL Cert. 6634 June 30,2014 9�,WARNTAG-—rdesign Parameters and READ NOTES ON TUTSAM MCLUlEO N1TEXREFEREAKI PAGE Nrr-7473.u. 1/29/20148FJUWUSE ■■■ Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the MiTek erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information va able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314 Tampa, FL 33fi10-4115 IiSauthernFine$SP Iwncr berissFefied,thedesignvaluesarethoseeffective06 01j1013hyr1L5C Job Truss Truss Type - City Ply Elev D [O'Cartion T6391341 in11324 KJA MONO TRUSS 2 1 Job Reference o do al Chambers I cuss Inc., Tort coerce 1-I. 348t$Z r eau s —P a cu is rvn i ert nwusnies, m, w,m aw — ruye ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-z69E9FQrEgbXs4cEKSrXCoW84nAgMpSuBexBJ1z17G1 -1-2-9 6-0-4 ' 1 2 9 6-04 Scale = 1:13.6 3x4 = LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud TCLL 20.0 Plates Increase 1.25 TC 0.22 Vert(LL) -0.05 2-4 >999 360 TCDL 7.0 Lumber Increase , 1.25 BC 0.17 Vert(TL) -0.08 2-4 >854 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix) LUMBER TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 REACTIONS (lb/size) 3=119/Mechanical, 2=148/0-9-11 (min. 0-1-8), 4=29/Mechanical Max Harz 2=97(LC 8) Max Uplift 3=-139(LC 8), 2=-169(LC 8) Max Grav 3=155(LC 13), 2=178(LC 2), 4=85(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. PLATES GRIP MT20 244/190 Weight: 20 lb FT = 0% BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 139 lb uplift at joint 3 and 169 lb uplift at joint 2. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-5=-44 Trapezoidal Loads (plf) Vert: 5=0(F=22, 8=22)-to-3=-66(F=-11, B=11), 2=-1(F=5, B=5)-to-4=-15(F=-3, B=-3) ♦♦�%0,QU I N 1,VF 1��i ♦ QP'.• �F��i i N 68182 .o T O F .' 41J e FL Cert. 6634 June 30,2014 ® WARNIM -Verify design parame mrs and READ M IFES ON 7NrSAND INIUOED fdrTER'REFEREAKM PAGE NII-7473 .. 1/Z912014BOU EUSE Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.�� Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsiblllity of the MiTek• erector. Additional pennanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPll Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information vai able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. Tampa, FL 33610-4115 if SDuthern pin umber is specified, the design values are those effective 0610112013 byALSC Job Truss Truss Type Qty Ply 70' Cerlton Elev D T6391342 mi1324 KJB MONOTRUSS 2 1 ob eee ce o do a Chambers Truss Inc., Fort Pierce FI. 34982 - f.3Du is aep zi zuIz rvn I eK mausmes, inc. man aun cu ii: ia:zn zu19 rage i ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-SJjcMbRT?JOUEBQtAMml?2 LiBXx5Gi1 NIhIsUz17GO -1-2-9 4-11-9 1-2-9 4-11-9 Scale = 1:11.7 3x4 = LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d TCLL 20.0 Plates Increase 1.25 TC 0.10 Vert(LL) -0.02 2-4 >999 360 TCDL 7.0 Lumber Increase 1.25 BC 0.10 Vert(TL) -0.03 2-4 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) LUMBER TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 REACTIONS (lb/size) 3=75/Mechanical, 2=123/0-9-11 (min. 0-1-8), 4=20/Mechanical Max Horz 2=73(LC 8) Max Uplift 3=-83(LC 8), 2=-156(LC 8) Max Grav 3=95(LC 13), 2=148(LC 2), 4=65(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. PLATES GRIP MT20 244/190 Weight: 17 lb FT = O% BRACING TOP CHORD Structural wood sheathing directly applied or 4-11-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 83 lb uplift at joint 3 and 156 lb uplift at joint 2. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1,25, Plate Increase=1.25 Uniform Loads (plf) Vert:1-5=-44 Trapezoidal Loads (plf) Vert: 5=0(F=22, B=22)4o-3=-55(F=-5, B=-5), 2=-1(F=5, B=5)4o-4=-12(F=-1, B=-1) % I N'1VF *: N 68182 T OF �'�� s � N AL E����• FL Cert. 6634 June 30,2014 ®WAMNS .1f.afr de,ign parama W ra and HERD N07ES ON TNISAND INaUDED MITEKREFEREME PAGE Mil-1473 .. 1/29120I4DUCIEVSE !� Design valld for use only with MITek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the MiTek• erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII quality Cdteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information va able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. Tampa, FL 33610.4115 tiSoutlrernPine�SP1 lumber is specified, the designxalLiesarethoseeffe�ctive0fi 0112013byALSG Job Truss Truss Type City Ply [O'CarltonElevl) T6391343 R111324 MV2 VALLEY 1 1 Job Reference (optional Chambers Truss Inc., Fort Pierce FI. 34982 T.3bu s sep zi zu12 M, I eK inaustnes, Inc. Mon Jun 3u 11:19:YS zG14 rage 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KK-SJjcMbRT?JOUEBQtAMml?2MvBYG5Gi 1 NIhIsUz17130 2-0-0 2-0-0 4.00 22 3x4 Scale = 1:6.1 LOADING (psf) SPACING 2-0-0 CS] DEFL in floc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.02 Vert(TL) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 5 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.3 TOP CHORD BOT CHORD 2x4 SP No.3 BOT CHORD REACTIONS (lb/size) 1=30/2-0-0 (min. 0-1-8), 2=24/2-0-0 (min. 0-1-8), 3=6/2-0-0 (min. 0-1-8) Max Horz 1=21(LC 8) Max Uplift 1=-20(LC 8), 2=30(LC 8) Max Grav 1=36(LC 13), 2=32(LC 13), 3=17(LC 3) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied or 2-0-0 oc purlins Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 20 lb uplift at joint 1 and 30 lb uplift at joint 2. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard ®WARNING-y frdesign Paramemrs and READ M7ES ON TNISAN0 INaUDE0 MITEKREFEREACE PAGE MII-7473.. 1/29/201480�GREUSE Design valid for use only with Welk connectors. This design is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component Safety Information gvauable from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 2314. IfSovthemPine:ISFplumberisspecified,thedesignvaluesarethoseeffective06 01/201313yALSO Qv I N VF *: N 68182 o • 44/ _ T OF ,,,'�ssll , •ALIE�Q � N /WWII FL Cert. 6634 June 30,2014 y MiTek• 6904 Parke East Blvd, Tampa, FL 33610-4116 Job Truss Truss Type Qty Ply Elev DT6391344 E'Cadton m11324 MV4 VALLEY 1 1b Reference (optionall Chambers Truss Inc., Fort Pierce FI. 34982 3x4 7.350 s Sep 27 2012 MiTek Industries, Inc. Mon Jun 30 11:19:25 2014 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-SJjcMbRT?JOUEBQtAMml?2JuBXX5Gi 1 NIhIsUz17G0 2x3 II Scale = 1:9.4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.22 Vert(LL) n/a n/a 999 MT20 2441190 TCDL 7.0 Lumber Increase 1.25 BC 0.13 Vert(TL) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 12 lb FT = 0% LUMBER BRACING TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, BOT CHORD 2x4 SP No.3 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 1=80/4-0-0 (min. 0-1-8), 3=80/4-0-0 (min. 0-1-8) Max Horz 1=56(LC 8) Max Uplift 1=-54(LC 8), 3=-72(LC 8) Max Grav 1=97(LC 13), 3=102(LC 13) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 1 and 72 lb uplift at joint 3. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard •)JWARNd.O-Vadfrdesign Parame M. and READ A07ES ON 7WAND INCLUDED MITEKREFEREN--PAGE MII-7473 rer.112912014BEFOREUSE Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabdcation, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB•89 and BCSI Building Component lately Information qva able from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 222314. IfSauthLTnpineI.SP lumbeaisspecified, the design values arethose effective06/01f2013hyALSC ol COIN V .•�,�G•E NSF • .�' Nc 68182 T OF O •• <U 00 IoN AL ��% ,nnu FL Cert. 6634 June 30,2014 MiTek' 6904 Parke East Blvd. Tampa, FL 33610-4115 PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0 -T' 1. For 4 x 2 orientation, locate plates 0-14a' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MITek 20/20 software or upon request. I I PLATE SIZE The first dimension is the plate width measured perpendicular 4 x 4 to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPII : National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing 8, Bracing of Metal Plate Connected Wood Trusses. Numbering System A General safety Notes 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 2 3 Tnp C'HcwnS C1-2 C2-3 c2q 4 WEBS o 0 U dab U IL O C7-8 C6-7 C5-6 BOTTOM CHORDS 8 7 6 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 _ER-3907, ESR-2362, ESR-1397, ESR-3282 Southern Pine lumber designations aye as follows: SYP represents values as published by AWC in the 2005/2012 NDS SP represents ALSC approved/new values with effective date of June 1, 2013 Failure to Follow Could Cause Property Damage or Personal Injury l . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I p bracing should be considered. O 3. Never exceed the design loading shown and never U stack materials on inadequately braced trusses. a_ O 4. Provide copies of this truss design to the building � designer, erection supervisor, property owner and all other interested parties. 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. C 2012 MiTekOO All Rights Reserved mm M!Tek MITek Engineering Reference Sheet: Mll-7473 rev. 01 /29/2013 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. r SPAWS LA®�QCES it Sail Eat ate\S\�_ 4r /s � 2—oir go/ NJ i FORMA05-10: FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION- - . . . . . . . . . . . . Florida e .Department of:Businss and Professional Regulation = Residential Performance :Method Project Name:_ WYNNE CARLTON 70 111. Builder -Name: WYNNE Street: ^ 2 n Permit Office: . �t City, State, Zip:FL., - Permit Number: Owner: Jurisdiction: .. Design Location: FL, Fort Pierce .1, New constructionorexisting . New(FromPlans) 9. Wall .Types (1788.5 sgft.)- insulation .: Area 2..Single family or multiple family. Single-family a: Concrete Block-- Int Insul,-Exterior R=4.2 1788.50 ft2. b. N/A .. R= .. ft2. . 3.-Number of units; if multiple family 1. c: N/A 4. Number of Bedrooms 3 d. N/A R=. ft2 . % Ceiling Types_ (1720:0 -sgft.) Insulation. Area Z. Is this a worst case? - .- No a: Under Attic (Vented): R=30.0 - .1720.00 ft2 - 6..Conditioned floor -area above grade (ft2) 1720 b. N/A_ R= ft2 . c: N/A R= ft� Conditioned floor area below grade (ft2) : 0 11. Ducts R ft2 -7. Windows(100.5 sgft.) - Description Area .-a. Sup: Attic,'Ret: Attic, AH: Attic 6 67.: a• u-Factor: .-"Sgl- U=1.30 100:50:ft2 SHGC:-: .. SHGC=0.50 b:. U-Factor:. NIA. ft2 12. Cooling systems - kBtu/hr - Efficiency. _SHGC: _a. Central Unit 35.4 SEERA5.00. c. U-Factor: N/A.. ft2. SHGC: 13. Heating.systems kBtu/hr - .Efficiency. d. U-Factor: N/A ft2 a. Electric Heat Pump 36.0 HSPF:8.50 1.SHGC: Area Weighted: Average Overhang Depth:. 0.617 ft:. Area Weighted Average. SHGC: 0.500 14. Hot water systems . a Electric Cap:-40 gallons 8..:Floor Types (1720.0.: sgft.) Insulation Area EF• 0.900 a. Slab; -On -Grade Edge insulation - R=0:0 1720.00 ft2 b. Conservation feature§. b. N/A. '. R=.. ft;. None c. N/A . R= ft2 15. Credits . None Total. Proposed Modified Loads: 30.53 0:058 PASS -Glass/Floor Area:. :. Total Standard Reference Loads: 39:5.4 .. I hereby certify that the plans and specifications .covered. by Review of the plans and . O�T$E STq� :this calculation are:in co pliance.with t Florida Energy-: specifications covered by this Code.: ' calculation indicates compliance {O with the Florida Energy Code. rrrr,'� - ''•'' �;� •��� PREPARED By- DATE: Before construction is completed this building will be inspected for-.1 compliance with Section.553.908 r ; 1 hereby certify. that this building, as des' g Is co liance , Florida Statutes:. COD ..with the Florida. Energy Code: WB`� r y. (OWNER/ EN -"- Lam:, BUILDING. OFFICIAL: DATE: DATE: . Compliance requires certification by the air handler unit manufacturer that the -air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 8/7/2014 3:54 PM-EnergyGauge®.USA - FlaRes2010 Section.405.4.1 Compliant Software Page 1 of 5 .: PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: WYNNE CARLTON 70 III Bedrooms: 3 User Conditioned Area: 1720 Total Stories: 1 1 Worst Case: No WYNNE Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address St. Lucie , FL, - CLIMATE V Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 1720 13760 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1720 13760 Yes 2 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 179 ft 0 1720 ft2 ---- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 1813 ft2 0 ft2 Light 0.5 N 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1720 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 1720 ft2 0.1 Wood 8/7/2014 3:54 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Ornt TO Wall Typepace S# 1 N Exterior Concrete Block - Int Insul Main 4.2 69 6 8 6 590.8 ft2 0 0 0.8 0 2 N Exterior Concrete Block - Int Insul Main 4.2 2 6 8 0 20.0 ft2 0 0 0.8 0 3 E Exterior Concrete Block - Int Insul Main 4.2 19 6 8 0 156.0 ft2 0 0 0.8 0 4 S Exterior Concrete Block- Int Insul Main 4.2 56 1 8 0 448.7 ft2 0 0 0.8 0 5 W Exterior Concrete Block - Int Insul Main 4.2 38 3 8 6 325.1 ft2 0 0 0.8 0 6 NE Exterior Concrete Block - Int Insul Main 4.2 31 0 8 0 248.0 ft2 0 0 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood Main None .6 3 7 21 ft2 2 NE Wood Main None .39 2 6 6 6 16.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Tinted) Yes 1.3 0.5 12.0 ft2 0 ft 6 in 0 ft 0 in None None 2 E 3 Metal Single (Tinted) Yes 1.3 0.5 20.0 ft2 1 ft 0 in 0 ft 6 in None None 3 S 4 Metal Single (Tinted) Yes 1.3 0.5 6.0 ft2 1 ft 0 in 0 ft 6 in None None 4 W 5 Metal Single (Tinted) Yes 1.3 0.5 30.0 ft2 1 ft 0 in 0 ft 6 in None None 5 W 5 Metal Single (Tinted) Yes 1.3 0.5 32.5 ft2 0 ft 0 in 0 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 2255.8 123.84 232.9 .365 9.8363 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 8.5 36 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 15 35.4 kBtu/hr 1062 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.9 40 gal 60.9 gal 120 deg None 8/7/2014 3:54 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS --- Supply ---- — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 67 ft2 Attic 20 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Heating Jan Feb Mar ki Apr Jun Jul May rl ri Aug rl Sep Oct Oct Nov Dec Dec Venting Jan Feb Mar lXJun� Jun Jul Aug Sep Oct Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 8/7/2014 3:54 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405.10 • ' Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: PERMIT #: , FL, - MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 8/7/2014 3:54 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 1. New construction or existing : New (From Plans) 9.: Wall Types Insulation. Area " 2. Single family' -or multiple family Single-family .. a, Concrete Block - Int Insul, "Exterior" ." R=4.2 ." 1788.50 ft2 ' " b. N/A R= ft 3. Number of units, if multiple family 1 c. N/A - R= ftz. 4. "Number of Bedrooms .. 3 d. N/A R= _ ft2 10. Ceiling Types Insulation Area 5. , Is this a worst case? No : a: Under Attic (Vented) R=30.0 . 1720:. 00 _ft2 6. Conditioned floor area (ft2) . 1720 b. N/A R= ft2 C. N/A R= ftzZ 7. Windows'* Description Area 11- Ducts R ft. a.- U-Factor:, - Sgl,-U=1.30 100.50 ft2 . .. :: a. Sup: Attic, Ret: Attic, AH: Attic . 6 67: " SHGC: SHGC=0.50: b. U-Factor:.. N/A. ft2 SHGC: 12. Cooling.systems - kBtu/hr . Efficiency. c. U-Factor: N/A = ft2 a. Central Unit: ..35.4 SEER:15.00 . .". SHGC: d. U-Factor:,. N/A. ft2 13. Heating -systems kBtu/hr" Efficiency-- - - SHGC: a: Electric Heat Pump 36.0 . HSPF:I3.50 Area Weighted Average: Overhang Depth: 0.617 ft. Area Weighted Average SHGC: .. 0:500 . 8..Floor Types _ Insulation ..Area 14. Hot water systems. Cap;.40 gallons .a. Slab -On -Grade Edge Insulation R=0.0 i 1720.00 ft2 a. Electric EF: 0.9 b: N/A R= .. " ftz. b. Conservation features c. N/A. R= . ft2 None - 15. Credits 'None -certify that this home has:com lied with.the Flori Ener Efficienc Code.for Buildin fY P gY Y . 9: �:�gE STAr Construction. through. the above energy: s g fe tures which will be -installed (or -exceeded) y� - - �o in this home before final inspection: is , a new EPL Display Card will -be completed - based'{'{ on. Installed Code comp' fe res . Bsi`il`tler'Si` `nature'° t x h Date:.. <' Address of New Home:: ����.�4 City/FL Zip:`-��Cp *Note: This is not.a Building Energy Rating.. if your Index is below.70, your. home may qualify for energy efficient mortgage. (EEM) incentives. if you obtain a Florida Ene:rgyGauge Rating.- Contact the EnergyGauge .Hotline:at-(321) 63&1492.or see the EnergyGauge.web site at energygauge.com for information and a list.of. certified. Raters. For " information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. *Label required by:Section 303.1.3 of the Florida. Bu.ilding.:Code; Ener-wConservation' if. not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1. Compliant Software a. '-�d- wrightsoft® Project Summary Entire House COMFORT CONTROL OF SLC, INC. A-4 CC MIIThAr)PC CT POPT CT i i irtiF Fi 34983 Phone, 772-878-2799 Fax: 772-785-9144 Web: ccmfortcontrolofslc.cam For: CARLTON 70 III BEDROOM, WYNNE BUILDING CORP. PORT ST. LU\CIIE, FL`34983 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 17840 Btuh Ducts 4282 Btuh Central vent (37 cfm) 1154 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 23276 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ftZ 1737 1737 Volume �ft3) 14996 14996 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 95 50 Heating Equipment Summary Make Carrier Trade COMFORT 15 PURON HP Model 25HCB536A30 AHRI ref 3032420 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 8.5 HSPF 36000 Btuh @ 47°F 28 OF 1180 cfm 0.053 cfm/Btuh 0 in H2O Job: Date: AUGUST 6, 2014 By: PATRICIA ZIMMEI Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 18932 Btuh Ducts 5254 Btuh Central vent (37 cfm) 618 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 23564 Btuh Latent Cooling Equipment Load Sizing Structure 2488 Btuh Ducts 1538 Btuh Central vent (37 cfm) 1566 Btuh Equipment latent load 5592 Btuh Equipment total load 29156 Btuh Req. total capacity at 0.70 SHR 2.8 ton Cooling Equipment Summary Make Carrier Trade COMFORT 15 PURON HP Cond 25HCB536A30 Coil FX4DN(13,F)037 AHRI ref 3032420 Efficiency 12.7 EER, 15 SEER Sensible cooling 24780 Btuh Latent cooling 10620 Btuh Total cooling 35400 Btuh Actual air flow 1180 cfm Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Aug-07 15:18:30 wrightsoft' Right -Suite® Universal 2015 15.0.00 RSU05864 Page 1 f1CCA ...uilders%Wynne Corp\WYNNE CARLTON 70 111 win.rup Calc = MJ8 Front Door faces: W - wrightsofta Right-J® Worksheet Entire House COMFORT CONTROL OF SLC, INC. 1501 SE BILTMORE ST.. PORT ST. LUCIE, FL 34983 Phone: 772-878-2799 Fax: 772-785-9144 Web: canfortcontrolofslc.cam Job: Date: AUGUST 6, 2014 By: PATRICIA ZIMMERMAN 1 Room name Entire House FOYER 2 Exposed wall 181.5 ft 6.0 ft 3 Room height 8.6 ft d 8.0 ft heat/cool 4 Room dimensions 6.0 x 17.5 ft 5 Room area 1743.8 ft' 105.0 ft' Ty Construction U-value Or HTM Area M Load Area (ft� Load number (Btuh/ft'-°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VI--G 12C-Osw 0.091 n 2.55 2.18 599 587 1495 1282 0 0 0 0 1Dc2om 0.870 n 24.36 27.10 12 0 292 325 0 0 0 0 W 13A-5ocs 0.125 n 3.50 2.22 20 20 70 44 0 0 0 0 12C-Osw 0.091 a 2.55 2.18 160 119 303 260 48 27 69 59 11 1A-r1ob 1.080 a 30.24 48.10 20 1 605 962 0 0 0 0 D 11J0 0.600 a 16.80 17.40 21 21 353 365 21 21 353 365 12C-Osw 0.091 s 2.55 2.18 453 447 1139 976 0 0 0 0 Vtl G 1A-riom 1.270 s 35.56 26.39 6 6 213 158 0 0 0 0 W 12C-Osw 0.091 w 2.55 2.18 329 246 627 537 0 0 0 0 1 D-c2ow 0.570 w 15.96 20.29 20 20 323. 411 0 0 0 0 1 D-c2ow 0.570 w 15.96 59.58 30 2 479 1788 0 0 0 0 4A5-2omd 0.770 w 21.56 19.31 33 33 701 627 0 0 0 0 P 128-Obw 0.097 - 2.72 0.85 252 236 640 201 128 128 348 109 L-D 11 DO 0.390 n 10.92 11.31 16 16 177 184 0 0 0 0 16A-30m1 0.032 0.90 2.32 1744 1744 1562 4046 105 105 94 244 C F 22A-tpm 1.180 33.04 0.00 1744 182 5997 0 105 6 198 0 6 c) AED excursion 1915 -24 Envelope loss/gain 14977 14082 1062 754 12 a) Infiltration 2933 827 90 25 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 0 Appliances/other 3600 1 Subtotal (lines 6 to 13) 17911 18969 1152 779 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 17911 0 18969 0 1152 0 779 14 15 Subtotal Duct loads 25% 28% 4396 5389 16% 18% 184 137 Total room load 22307 24359 1336 i 916 Air required (cfm) 1180 1180 71 44 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. � wright:soft' 2014 Aug-07 15:ge I - Right -Suite® Universal 2015 15.0.00 RSU05864 Page AC�Z`.A ...uilders%Wynne Corp1WYNNE CARLTON 70 111 win.rup Calc = MJ8 Front Door faces: W wrightsoft° Right-J® Worksheet Entire House COMFORT CONTROL OF SLC, INC. 1501 SE BILTMORE ST., PORT ST. LUCIE, FL 34983 Phone: 772-878-2799 Fax 772-785-9144 Web: comfortcontrolofslc.com Job: Date: AUGUST 6, 2014 By: PATRICIA ZIMMERMAN 1 Room name LAUNDRY KITCHEN 2 Exposed wall 7.5 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 7.5 ft 1.0 x 144.0 ft 5 Room area 52.5 ft2 144.0 ft' Ty Construction U-value Or HTM Area (ftl Load Area M Load number (Btuh1W °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6T--G12C-0sw 0.091 n 2.55 2.18 0 0 0 0 0 0 0 0 1 D-c2om 0.870 n 24.36 27.10 0 0 0 0 0 0 0 0 W 13A-5ocs 0.125 n 3.50 2.22 0 0 0 0 0 0 0 0 12C-Osw 0.091 a 2.55 2.18 0 0 0 0 0 0 0 0 11 G 1A-r1ob 1.080 a 30.24 48.10 0 0 0 0 0 0 0 0 D 11J0 0.600 a 16.80 17.40 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 s 2.55 2.18 60 60 153 131 0 0 0 0 L-G 1A-r1om 1.270 s 35.56 26.39 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 w 2.55 2.18 0 0 0 0 0 A 0 0 1 D-c2ow 0.570 w 15.96 20.29 0 0 0 0 0 0 0 0 1 Dc2ow 0.570 w 15.96 59.58 0 0 0 0 0 0 0 0 4A5-2omd 0.770 w 21.56 19.31 0 0 0 0 0 0 0 0 P 12B-Obw 0.097 - 2.72 0.85 56 40 108 34 68 68 185 58 L-D 11 DO 0.390 n 10.92 11.31 16 16 177 184 0 0 0 0 C 16A-30ml 0.032 0.90 2.32 53 53 47 122 144 144 129 334 F 22A-tpm 1.180 33.04 0.00 53 8 248 0 144 0 0 0 6 c) AED excursion -50 -82 Envelope loss/gain 733 420 314 310 12 a) Infiltration 113 32 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 1200 2400 Subtotal (lines 6 to 13) 1 846 1652 13141 2710 Less external load 0 0 0 0 0 0 Less transfer 0 0 0 0 0 0 Redistribution 846 1652 314 2710 14 15 Subtotal Duct loads 16% 18% 135 291 16% 18% 50 477 Total room load 981 1 1943 364 3187 Air required (cfm) I 521 941 1 1 19 154 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Aug-07 15:19:29 .4C�A� wrightsoft" Right -Suite® Universal 2015 15.0.00 RSU05864 Page 21 ..uilders\Wynne Corp\WYNNE CARLTON 70 111 win.rup Calc = MJ8 Front Door faces: W wrightsoft' Right-J® Worksheet Entire House COMFORT CONTROL OF SLC, INC. 1501 SE BILTMORE ST., PORT ST. LUCIE, FL 34983 Phone: 772-878-2799 Fax: 772-785-9144 Web: comfortcontrolofslc.com Job: Date: AUGUST 6, 2014 By: PATRICIA ZIMMERMAN! i 1 Room name MS BATH MS CLOSET 2 Exposed wall 8.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 8.0 ft 7.0 x 9.0 ft 5 Room area 56.0 ft' 63.0 ft2 Ty Construction U-value Or HTM Area M Load Area (ftl Load number (Btuh/ft' °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 2.55 2.18 0 0 0 0 0 0 0 0 I--G 1 D-c2om 0.870 n 24,36 27.10 0 0 0 0 0 0 0 0 W 13A-5ocs 0.125 n 3.50 2.22 0 0 0 0 0 0 0 0 12C-Osw 0.091 a 2.55 2.18 0 0 0 0 0 0 0 0 11 1A-r1ob 1.080 a 30.24 48.10 0 0 0 0 0 0 0 0 11J0 0.600 a 16.80 17.40 0 0 0 0 0 0 0 0 12C-Osw 0.091 s 2.55 2.18 64 58 148 127 0 0 0 0 1A-r1om 1.270 s 35.56 26.39 6 6 213 158 0 0 0 0 W 12C-Osw 0.091 w 2.55 2.18 0 0 0 0 0 0 0 0 1 Dc2ow 0.570 w 15.96 20.29 0 0 0 0 0 0 0 0 1 D-c2cw 0.570 w 15.96 59.58 0 0 0 0 0 0 0 0 4A5-2omd 0.770 w 21.56 19.31 0 0 0 0 0 0 0 0 P 126-0bw 0.097 - 2.72 0.85 0 0 0 0 0 0 0 0 L-D 11 DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0 C 16A-30ml 0.032 0.90 2.32 56 56 50 130 63 63 56 146 F 22A-tpm 1.180 33.04 0.00 56 8 264 0 63 0 0 0 6 c) AED excursion -13 -4 Envelope loss/gain 676 402 56 142 12 a) Infiltration 120 34 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 0 Appliances/other 01 Subtotal (lines 6 to 13) L 796 436 56 142 Less external load 0 0 0 0 0 0 Less transfer 0 0 0 0 0 0 Redistribution 796 436 56 142 14 15 Subtotal Duct loads 16% 15% 127 65 32% 43% 18 60 Total room load 923 501 74 202 Air required (cfm) 49 24 4 101. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ad-wri htsoft' 9 2014-Aug-0715:19:2$ 9 Ri ht-Suite® Universal 2015 15.0.00 RSU05864 Page 3 �� ...uilders\Wynne Corp\WYNNE CARLTON 70 111 win.rup Calc = MJ8 Front Door faces: W wrightsoft' Right-J® Worksheet Entire House COMFORT CONTROL OF SLC, INC. 1rn1 RF RIITMnRF ST PnRT ST_ LUCIE. FL 34983 Phone: 772-878-2799 Fax 772-785-9144 Web: comfortcontrolofslc.com Job: Date: AUGUST 6, 2014 By: PATRICIA ZIMMERMAN i 1 Room name MS BDRM HALL 2 Exposed wall 50.0 ft 0 ft 3 Room height 8.5 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 311.5 ft 4.5 x 5.0 ft 5 Room area 311.5 ft2 22.5 ft' Ty Construction U-value Or HTM Area (M Load Area (ft� Load number (Btuh/W °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12C-0sw 0.091 n 2.55 2.18 85 85 217 186 0 0 0 0 L -G 1 D-c2om 0.870 n 24.36 27.10 0 0 0 0 0 0 0 0 W 13A-5ocs 0.125 n 3.50 2.22 0 0 0 0 0 0 0 0 lj 12C-Osw 0.091 a 2.55 2.18 0 0 0 0 0 0 0 0 11 �G 1A-r1ob 1.080 a 30.24 48.10 0 0 0 0 0 0 0 0 t-D 11,10 0.600 a 16.80 17.40 0 0 0 0 0 0 0 0 12C-Osw 0.091 s 2.55 2.18 221 221 563 483 0 0 0 0 IW L-v IA-rlom 1.270 s 35.56 26.39 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 w 2.55 2.18 119 89 227 194 0 0 0 0 1 D-c2ow 0.570 w 15.96 20.29 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 15:96 59.58 30 2 479 1788 0 0 0 0 4A5-2omd 0.770 w 21.56 19.31 0 0 0 0 0 0 0 0 PII 12B-Obw 0.097 - 2.72 0.85 0 0 0 0 0 0 0 0 -- L--D 11 DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0 C 16A-30ml 0.032 0.90 2.32 312 312 279 723 23 23 20 52 F 22A-tpm 1.180 33.04 0.00 312 50 1652 0 23 0 0 0 6 c) AED excursion 857 -2 Envelope loss/gain 3416 4230 20 51 12 a) Infiltration 799 225 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1 01 0 Subtotal (lines 6 to 13) 4215 4455 201 51 Less external load 0 0 0 0 0 0 Less transfer 0 0 0 0 0 0 Redistribution 4215 4455 20 51 14 15 Subtotal Duct loads 32%1 43% 1328 1900 32% 43% 6 22 Total room load 5544 6354 27 72 Air required (cfm) 293 308 1 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4�11-wri t�tsotrt' 9 2014-Aug-0715:19:29. i9C�A9 Ri ht-Suite® Universal 2015 15.0.00 RSU05864 Page 4 ..uilders\Wynne Corp\WYNNE CARLTON 70 111 win.rup Calc = MJ8 Front Door faces: W wrightsoft° Right-J® Worksheet Job: Entire House Date: AUGUST 6, 2014 By: PATRICIA ZIMMERMAN COMFORT CONTROL OF SLC, INC. 1501 SE BILTMORE ST., PORT ST. LUCIE, FL 34983 Phone: 772-878-2799 Fax: 772-785-9144 Web: comfort controlofslc.corn 1 Room name BATH BDRM 2 2 Exposed wall 5.0 ft 42.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x 5.0 ft 1.0 x 207.3 ft 5 Room area 45.0 ft' 207.3 ft' Ty Construction U-value Or HTM Area (ft� Load Area (W) Load number (Btuh/ft''F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12C-0sw 0.091 n 2.55 2.18 40 40 102 87 112 112 285 245 T 1 D-c2om 0.870 n 24.36 27.10 0 0 0 0 '0 0 0 0 W 13A-5ocs 0.125 n 3.50 2.22 0 0 0 0 0 0 0 0 12C-Osw 0.091 a 2.55 2.18 0 0 0 0 112 92 234 201 11 IA-rlob 1.080 a 30.24 48.10 0 0 0 0 20 1 605 962 D 11J0 0.600 a 16.80 17.40 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 s 2.55 2.18 0 0 0 0 108 108 275 236 1A-rlom 1.270 s 35.56 26.39 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 w 2.55 2.18 0 0 0 0 4 4 10 9 D-c2ow 0.570 w 15.96 20.29 0 0 0 0 0 0 0 0 t1 -G 1 Dc2ow 0.570 w 15.96 59.58 0 0 0 0 0 0 0 0 4A5-2omd 0.770 w 21.56 19.31 0 0 0 0 0 0 0 0 P 12B-Obw 0.097 - 2.72 0.85 0 0 0 0 0 0 0 0 L-D 11 DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0 16A-30ml 0.032 0.90 2.32 45 45 40 104 207 207 186 481 C F 22A-tpm 1.180 33.04 0.00 45 5 165 0 207 42 1388 0 6 c) AED excursion -6 -50 Envelope loss/gain 307 185 2983 2083 12 a) Infiltration 75 21 632 178 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 383 207 3615 2261 Less external load 0 0 0 0 0 0 Less transfer 0 0 0 0 0 0 Redistribution 383 207 3615 2261 14 15 Subtotal Duct loads 32% 43% 121 88 32% 43% 1139 964 Total room load 503 295 4754 3225 Air required (cfm) 1 27 141 2511 156 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i F�tsoft' g 2014-Aug-0715:19:29 wr 9 Ri ht-Suite® Universal 2015 15.0.00 RSU05864 Page 5 AC(ffk ... uilders\Wynne Corp\WYNNE CARLTON 70 111 win.rup Calc = MJB Front Door faces: W +- wrightsoftm Right-J® Worksheet Entire House COMFORT CONTROL OF SLC, INC. 1501 SE BILTMORE ST., PORT ST. LUCIE, FL 34983 Phone: 772-878-2799 Fax: 772-785-9144 Web: canfortcontrolofslc.com Job: Date: AUGUST 6, 2014 By: PATRICIA ZIMMERMAN 1 Room name CLOSET BDRM 3 2 Exposed wall 2.5 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x 2.5 ft 13.5 x 14.0 ft 5 Room area 22.5 ft' 189.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area M Load number (Btuh/ft? °F) (Btuh/ft� or perimeter (ft) . (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1q/ 12C-Osw 0.091 n 2.55 2.18 0 0 0 0 112 100 255 218 �G 1 D-c2om 0.870 n 24.36 27.10 0 0 0 0 12 0 292 325 W 13A-5ocs 0.125 n 3.50 2.22 20 20 70 44 0 0 0 0 12C-Osw 0.091 a 2.55 2.18 0 0 0 0 0 0 0 0 11 1A-r1ob 1.080 a 30.24 48.10 0 0 0 0 0 0 0 0 ���--DDD 11J0 0.600 a 16.80 17.40 0 0 0 0 0 0 0 0 V11 12C-Osw 0.091 s 2.55 2.18 0 0 0 0 0 0 0 0 I--G 1A-r1om 1.270 s 35.56 26.39 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 w 2.55 2.18 0 0 0 0 0 0 0 0 1 Dc2ow 0.570 w 15.96 20.29 0 0 0 0 0 0 0 0 1 Dc2ow 0.570 w 15.96 59.58 0 0 0 0 0 0 0 0 4A5-2omd 0.770 w 21.56 19.31 0 0 0 0 0 0 0 0 P 128-0bw 0.097 - 2.72 0.85 0 0 0 0 0 0 0 0 L-D 11D0 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0 16A-30ml 0.032 0.90 2.32 23 23 20 52 189 189 169 438 C F 22A-tpm 1.180 33.04 0.00 23 3 83 0 189 14 463 0 6 c) AED excursion -3 -31 Envelope loss/gain 173 94 1179 951 12 a) Infiltration 38 11 211 59 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 210 104 1390 1011 Less external load 0 0 0 0 0 0 0 0 Less transfer 0 0 0 0 Redistribution 210 104 390 1438 1011 14 15 Subtotal Duct loads 32% 43% 66 44 32% 43% 38 43131 Total room load 277 149 1827 97 1442 70 Air required (cfm) 15 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri F�tsoft" 9 2014-Aug-0715:19:29 /I Z-= 9 Ri ht-Suite® Universal 2015 15.0.00 RSU05864 Page 6 ..uilders\Wynne Corp\WYNNE CARLTON 70 111 win.rup Calc = MJ8 Front Door faces: W wrightsoft® Right-J® Worksheet Entire House COMFORT CONTROL OF SLC, INC. 1501 SE BILTMORE ST., PORT ST. LUCIE, FL 34983 Phone: 772-878-2799 Fax: 772-785-9144 Web: confortcontrolofslc.cam Job: Date: AUGUST 6, 2014 By: PATRICIA ZIMMERMAN 1 Roam name LIVING RM 2 Exposed wail 46.5 ft 3 Roam height 9.8 ft heat/cool 4 Room dimensions 1.0 x 525.5 ft 5 Room area 525.5 ft' Ty Construction U-value Or HTM Area (M Load Area Load number (Btuh/ft' °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Coal 6 1RV 12C-0sw 0.091 n 2.55 2.18 250 250 637 546 i--G 1 D-c2om 0.870 n 24.36 27.10 0 0 0 0 W 13A-5ocs 0.125 n 3.50 2.22 0 0 0 0 l 12C-0sw 0.091 a 2.55 2.18 0 0 0 0 11 I-G 1A-rlob 1.080 a 30.24 48.10 0 0 0 0 11J0 0.600 a 16.80 17.40 0 0 0 0 -D 12C-0sw 0.091 s 2.55 2.18 0 0 0 0 1A-r1om 1.270 s 35.56 26.39 0 0 0 0 W 12C-0sw 0.091 w 2.55 2.18 206 153 390 334 1 D-c2ow 0.570 w 15.96 20.29 20 20 323 411 1Dc2ow 0.570 w 15.96 59.58 0 0 0 0 4A5-2omd 0.770 w 21.56 19.31 33 33 701 627 PII 12B-Obw 0.097 - 2.72 0.85 0 0 0 0 -- �--D 11D0 0.390 n 10.92 11.31 0 0 0 0 C 16A-30ml 0.032 0.90 2.32 526 526 471 1219 F 22A-tpm 1.180 33.04 0.00 526 47 1536 0 6 c) AED excursion 1323 Envelope loss/gain 4058 4461 12 a) Infiltration 857 241 b) Room ventilation 0 0 13 Intemal gains: Occupants @ 230 2 460 Appliances/other 0 Subtotal (lines 6 to 13) 4914 5162 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 4914 5162 15 Duct loads 16% 18% 784 909 Total roam load 5698 6071 Air required (cfm) 301 294 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. g 2014-Aug-0715:19:29 ..1 . wriF�tsoft' Ri 9 Right-Sufte® Universal 2015 15.0.00 RSU05864 Page 7 ACCA ...uilders\Wynne Corp\WYNNE CARLTON 70 111 win.rup Calc = MJ8 Front Door faces: W II" F SURVEY: BOUNDARY PLOT PLAN U C TIE IN FINAL I TOPOGRAPHIC COMPLETED ON: 10-03-14 DESCRIPTION: o SURVEYORS NOTES: BEING ALL OF 23 VILLA BLANCA, OF 1. UNLESS OTHERWISE NOTED ONLY PLATTED EASEMENTS ARE THE UNRECORDED PLAT OF COUNTRY CLUB W. SHOWN HEREON. NO UNDERGROUND UTILITIES OR IMPROVEMENTS WERE VILLAGE, OF ST. LUCIE COUNTY, 2. FLORIDA. �` LOCATED UNLESS OTHERWISE SHOWN. ? 3. THIS SITE LIES WITHIN FLOOD ZONE "X", ACCORDING TO WR THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO. ABBREVIATIONS: Q 12111CO070 J, EFFECTIVE DATE 2-16-12. FIFE = FINISHED FLOOR ELEVATION o U L 4. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATION BY THE SURVEYOR AND IS PROVIDED AS A COURTESY. THE FLOOD R/W = RIGHT-OF-WAY U U ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY. R = RADIUS OF CURVE a cn 5. BEARINGS SHOWN HEREON ARE REFERANCED TO THE L = LENGTH OF CURVE CENTERLINE OF VILLA BLANCA HAVING AN ASSUMED SF = SQUARE FOOT BEARING OF EAST, ACCORDING TO THE UNRECORDED PLAT A = DELTA OF CURVE OF COUNTRY CLUB VILLAGE, OF ST. LUCIE COUNY, o FLORIDA n 6. NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LISCENSED SURVEYOR AND MAPPER. 7. THIS IS A SPECIFIC PURPOSE SURVEY FOR THE PURPOSE OF LOCATION AND ELEVATION OF FORMBOARDS. BOUNDARY LINES SHOWN HEREON ARE FOR GRAPHICAL PURPOSES ONLY. St. U le Co. DateI �I Init prove EDGE OF WATER` 23 VILLA BLANCA PERMIT #: 1�0 � - c-) -3 3 P G 0�P w P0 PO ti SCALE: 1 "=30' ALEXANDER J. PIAZZA PSM, INC. DATE:10-03-14 Surveying • Mapping • Consulting 619 SW Biltmore Street DRAWN: CJM*LEBf7280 Port St. Lucie, Florida 34983 JOB NO.: Phone: (772) 340-7770 14-1854 Fax: (772) 340-2250 IZ4169[d'l,5l LAST FIELD DATE: 10-03-14 CERTIFIED TO: WYNNE BUILDING CORPORATION r 1"4e-v� ALEXAND J. PIAZ Professional urveyor do Mapper Florida Certificate No.: 6330 K:\BUILDERS\DWG2014\DWG\14-1854.dwg, 10/3/2014 2:44:47 PM