Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
ALL -APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED SCANNED Date: $� oLG 6 t{ BY Permit Number: t 1A 07 - d 3 `I St. Lucie County Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential_ PERMIT APPLICATION FOR: To Select from dropbox, click arrow at the end of line PROPOSED IMPROVEMENT. �LOOCATION: Address: 1 Z D S \� 0 lc L U, �PL. , Legal Description: Cj S / b O L4 Q n E CD R Lc, i- Z l P Vl V\ b1 S IJ T- 1 2- I Z- iFt Properly Tax lD#: 3y©�-.�D2-C)Z?,1 -Oc7o- Lot No. Site Plan Name: Block No. Project Name: Setbacks Front Back: Right Side: Left Side: DETAILED DESCRIPTION OF WORK: 1 E&k d iF P I At r0) 12 f �a-c w� lM odt e J Sp�-v / s V CONSTRUCTION INFORMATION: I Haatttonal worts to ne errormea unaer tnis permit- cnecK an apply: ®HVAC Gas Tank Gas Piping _ Shutters ❑ Windows/Doors ❑ Electric 0 Plumbing Sprinklers ❑ Generator L1 Roof Total Sq. Ft of Construction: i �� P S S . Ft. of First Floor: Cost of Construction: $ aj L M Utilities: Sevirer ❑Septic Building Height: OWNER/LESSEE:. CONTRACTOR: Name L�Q; *,) 5-ro nt 3,., Name: Rnt, ,a- a,a-` It4 Address:_ 2503 /V L,) Company: -F EPt4(�c Ati't (!�O ✓ r& ccy) City: PWM�,'' State: 1FL- Address: 3 �J ,4,2g 4- City: 1:)orF- S LLL-L is Stater Zip Code: 3 4(c7 '� Fax: Phone No. -17 2— Za (- S Z ZZ0 0 VIDy Zip Code: 3C19SS Phone No. % 7 2- 7 Fax: '7 72 -`ADS -(4 0 E-Mail: Fill in fee simple Title Holder on next page'( if different E-Mail: TC C o n C e,D tS o-o (• CA Lk, from the Owner listed above) State or County License: C CC I S 3 0 2 (o Z If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable Name: Address: MORTGAGE COMPANY: _ Not Applicable Name: Address: City: State: Zip: Phone: City: State: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable Name: BONDING COMPANY: Not Applicable Name: Address: Address: City: City: Zip: Phone: Zip: Phone: - 1 certify that no work or installation has commenced prior to the issuance of a. permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply_ In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencine work or recordine vour Notice of Commencement. STATE OF Ft'ORIDA COUNTY OF IL v c. ; The fo oing instrument was acknowledged before me this d day off 20 14 by STATE OF FLORIDA COUNTYOF Sk.Luc�� The fing in ment was acknowledged before me thiseorgoday of 20__14 by k0`ntk. 4 L*� iN'1*. I °�0 \G L'gN.�sh(Name of person acknowledging) (Name of person acknowledging) (Signature of Notary Personally Known Type of Ident" Commission Revised 07/15/2014 State of Florida) _ I (Signature of Notary Flca n Personally Knownate of fla18a Type of Identification Expires Dec BoneedThtough Assn. Commission No. State of Florida ) Notary ubl' - State of Florida My Co ?Aires Dec 16, 2011 Commission 4 EE 858761 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS i r Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Faxw 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit # 3L-C- ) y L-A -b3"4(0 I, licensed as a( Contractor* Engineer/Architect (Please print name & circle license type) *FS46 uilding Inspector *General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about 8) Z-Rj I q , I did personally inspect the roof deck naili (Date) work at: 1 Z (Job site address) Based upon that examination I have determined the installation was done according to the current edition of the Florida Existing Building Code Section 611 or the product approval submitted (whichever is mosXSrlg,5>,�),� CcC 1,�33d3�� ignat and Seal U License # STATE OF FLORIDA COUNTY OF jE S to an subls�}rib-ed before me this th d 20�� by rnA Who is ersonally known a or who has produced as identifica ton. Notary Public, State tyqF� lY,,,x �:ANDREALAITA Signature of Notary: WCOMMISSION EE2IPTl9 Commission Number:Z-� 2 „... EXPIRES: June28,2016 •.,p�,.• Bonded Thru Notary Public Underwriters En 01/19/2011 . t6 _-_-_--_- -_' 4 . �,:+� . Sri y� -'^+ .� `+� �•7 .�„�.. FILE Copy MAUL W hIbUn IIN U. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite# 114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email: pweichinc(iDaoi.com August 22, 2014 Re: Broadstone'Inc. Residential Re -Roof 1205 Country Garden Ln. Fart Pierces FL 34982 SMPE OF MMUL - Remove existing roofing at flat deck roof at the rear of the existing residence roof. - Re -nail existing roof sheathing. - Install new roofing. Pollyglass SBS-SA. Roofing (FL# 1654,1 % 12) T-{f1T11'�T Z1TIiV'� T'�' DESIRGI�I CR L� RIA: FBC 2010 ASCE7-10 PROJECT DATA: Bzuna;,— H-i =8' A= 3' Mean Roof Hieght = 15' Roof Pitch = 0.5:12 Shape = Mono Low Slope Adjusixnent Factor = 1 _00 Improtance Factor =1.00 Wind Velocity Vult =160 mph (3 sec.) l Vasd =124 mph Exposure = C Enclosure Class = Enclosed Building Internal Pressure Coefficient = -0.18 APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (ASCE 7-10) : Zone 1(Field) _ -33.6 PSF Zorie 2 (Periiiieter"/ Ridge) _ -56.3 PSF Zone 3 (Comers) _ -84.7 PSF 1205 Country Garden Ln.Fort Pierce, FL 34982 1 of 3 1tVljil' DATA; Manufacturer: Pollyglass USA Type: Non -Insulated, Bonded Roof System. for Wood Decks FL#: 1654.1 R-12 Sy-rs — N"jMb�a,i : uI S I T.M. l.F ! pa 1 i of 3-i Design Pressure: DP = -90 psf Cap: Elastoflex SA P Base Sheet: Elastoflex SA V Deck: 19/32" Plywood RT tI,i-t y. i�ti-=YFA=li L.fZiTRIL`4 1(VOJ�Itii Al 1A I�1VlL' lr � Apply Base Sheet over clean, dry, dust and debris -free plywood. Apply Base Sheet, start at the low point of the roof, unroll the material and allow material to relax prior to installation. Fold thealignc4 mcmbr4ne, ut balf, e3Wsmg the rcleaw film, peel Fcleae film. at 90° angle in a constant motion ensuring to keep weight on the outer edges as you progress. Posisition the next sheet L- overlapping semi and 1*- r he overlap ofthe top sheet edge with the hmide of the bottom sheet's factory selvage SEALLap edges. Overlap and cut end laps minimum of 6". Press the membrane into place with firm, even pressure. After adhering rolls apply uniform pressure to entire sheet, after each in place, using 801b linoleum roller. Roll seams and edges firmly with steel or other suitable roller to ensure full adhesion. Details are carried out by using a hot-air welding mastic technique or Pollyglam PCT 500 SBS TROWF,I Grade. Heatxhould be applied with flameless torch or hot-air welder (open flame torches are not recommended). Apply Cap sheet over Base Sheet in similar manner. Refer to manufacturers installation instructions for more information. All zones require same attachment 90 nsf > 84.7 usf Therefore OX DECK RgSTiALLAliON: Re -nail all plywood sheathing (19/32" thick minimum) with 8D ring -shank nails at 4" O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (1654.1 R-12) manufacturer's s iiectuoiiS, etiiu the Florida Miiuuig wuC Aviv. Submitted by: PA LCH INC. Pau- ell ch,. P. . Reg. No 29945 PW:pj . - : . . 1205 Eornfty Gwden L&Fed Pmree, FL 349K 2 of ROOT ZONE PLAN A=3' 0,Q= ZONE DESIGNA77GN (IMCALJ 1205 +Cuuufiy vatdcu i n.Futt Firicu, ri. 349982 PAUL WELCH INC. MECH-ELECT-CIVIL ENG 1984 BILTMORE ST. r 114 PORT ST. LUCIE, FL 34984 PAUL WELCH, P.E. FLA REG NO 29945 AUG 2'Y 2014 rn rif �: - FLOWDA,011PARTMOW OF MI Business & Professional Regulation COPY �l Florida Departments BCIS Home I Log In I User Registration I Hot Topic Submit Surcharge I Slats & Facts I Publications I FBC Staff � BCIS Site Flap � Links I Search I Bus ines Profeproval ssi gal s US R: PubliicUser Regulation Product ADDroval Menu > Product or ADDllcation Search > Aoolication List > App"n-Detail FL # FL1654-R12 Application Type Revision Code Version 2010 Application Status Approved Comments Archived ■ Product Manufacturer POLYGLASS USA Address/Phone/Email 150 Lyon Drive Fernley, NV 89408 (570) 384-1230 Ext 242 jakins@polyglass.com Authorized Signature James Akins jakins@polyglass.com Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive Fernley, NV 98408 (602) 363-7139 st evew @ polyg la ss. c o m Quality Assurance Representative James Akins Address/Phone/Ernail 555 Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800) 894-4563 jakins@polydiass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ■ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/08/2015 Validated By John W. Knezevich, PE ■ Validation Checklist - Hardcopy Received Certificate of Independence FL1654 R12 COI Trinity ERD CI - Niemnen - 2013.1)df Referenced Standard and Year (of Standard) Standard ASTM D6163 ASTM D6164 ASTM D6222 ASTM D6509 FM 4470 FM 4474 Equivalence of Product Standards Certified By Year 2000 2005 2002 2000 1992 2004 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/21/2013 Date Validated 08/26/2013 Date Pending FBC Approval 09/08/2013 Date Approved 10/18/2013 Date Revised 07/01/2014 Summary of Products FL # Model, Number or Name Description 1654.1 Polyglass SBS and APP Modified SBS and APP modified bitumen roof systems Bitumen Roof Systerrs Limits of Use Installation Instructions Approved for use in HVHZ: No FL1654 R12 II Al ER082113FINAL POLYGLASS MODBIT FL1654- R12.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nierninen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this application relates to one Evaluation Reports particular asserrflly over concrete deck. Refer to the ER Appendix FL1654 R12 AE ER082113FINAL POLYGLASS MODBIT FL1654- R12.Ddf for other systems and deck types. 2.) Refer to ER, Section 5 for other Limits of Use. Created by Independent Third Party: Yes Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-.1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility, Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here . Product Approval Accepts: ® © eClixt M Credit.SAFE no \I TRINITY I ERD APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4-5 1A-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 7 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 7 ID Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 8 1E Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 9-11 1F Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 11 2A Steel or Conc. New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulatlon, Bonded Roof Cover 12 2B Steel or Conc. New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 13 2C Steel or Conc. New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14 3A-1 Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 15-18 3A-2 Concrete New or Reroof (Tear -Off) A-1 Bonded Temporary Roof, Bonded Insulation, Bonded Roof Cover 18-19 3B Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 19 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 20-21 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 21 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech, Attached Base Sheet, Bonded Roof Cover 22-24 5A CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 25 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 26 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 27 5D CWF New, Reroof (Tear -Off) or Recover C Mech, Attached Insulation, Bonded Roof Cover 27 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech, Attached Base Sheet, Bonded Roof Cover 27 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 28 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 28-29 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 29 6D Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 29 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 30-31 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 31 The following notes_ apply to the systems outlined herein: 1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: > Wood: Minimum 0.75-inch penetration. Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. �o Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polylsocyanurate, polystyrene, wood fiberboard, perlite, DensDeck, DensDeck Prime, DensDeck DuraGuard, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board that meets the QA requirements of F.A.C. Rule 9N-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. Exterlor Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R10 for FL1654-1112 Certificate of Authorization #9503 Revision 10: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page I of 31 rTRINI-ryIERD 4. Minimum 200 psi, minimum 2-inch thick lightweight Insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. 5. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted In the manufacturer's published Instructions. HA (HA): Full coverage at 25-30 Ibs/square. Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-Inch wide ribbons, 12-inch o.c. Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-Inch wide ribbons, 12-Inch o.c. OMG OlyBond 500 (OB500): Continuous 0,75 to 1-Inch wide ribbons, 12-Inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. s OlyBond Classic (OB Classic): Full coverage at 1 gal/square. Z 3M CR-20: Continuous 2.5-3.5-Inch wide ribbons, 12-inch o.c, Note: TITESET may be used where CR-20 is referenced. D Note, When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the specified ribbons spacing. 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to `Increase' the MDP listings in the tables; rather If MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: D Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-Inch thick) D OMG OlyBond 500 (OB500): MDP -45.0 psf (Min, 0.5-inch thick Multi -Max FA-3) D OMG OlyBond 500 (08500): MDP -187.5 psf (Min. 0.5-Inch thick ISO 95+ GL) > OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-Inch thick ENRGY 3) > OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II) 3M CR-20: MDP -117.5 psf (Min, 1.0-Inch thick) 7. Bonded polyisocyanurate Insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed, the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth In Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis Is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be In accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover Installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project.design pressures on Its own merit to the satisfaction of the AHJ, as documented through field upllft testing In accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124. 12. For Recover Applications using System Type D, the Insulation is optional; however, the existing roof system shall be suitable for a recover application. Exterior Research and Design, LLC, d/b/a TrinitylERD Evaluation Report P9290.02.08-R10 for FL1654-R12 Certificate of Authorization #9503 Revision 10: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 31 �l TRINITY ERD 13. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. TABLE 1: POLYGLASS ROOF COVERS Reforence Layer Material Application BP -AA (Base and Ply sheets, Asphalt -Applied) Base Polyglass G2 Base, FBC Approved ASTM D4601, Type II HA at 20.40lbs/square Ply FBC Approved ASTM D2178, Type IV or VI or ASTM D4601, Type II SBS-AA (SBS, Asphalt -Applied) Base or Ply Elastobase, Elastobase Poly, Elastoflex V, Elastoflex S6 HA at 20-40 Ibs/square Cap Elastoflex S6, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko MOP, Polyfresko MOP FR SBS-TA (SBS, Torch -Applied) Base or Ply Elastoflex V, Elastoflex S6 Torch -Applied Cap Elastoflex V, Elastoflex S6, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshleld TS-G FR, Polyfresko MOP, Polyfresko MOP FR SBS-SA (SBS, Self -Adhering) Base Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR Self -Adhering Cap Elastoflex SA P, Elastoflex SA P FR, Polyfresko SBS SAP, Polyfresko SBS SAP FR APP-TA (APP, Torch -Applied) Base or Ply Polyglass APP Base, Polyflex, Polybond Torch -Applied Cap Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko Torch, Polyfresko Torch FR APP-SA (APP, Self -Adhering) Cap Polyflex SA P, Polyflex SA P FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Polykooi, Polyblanko Self -Adhering 14. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. _ D PG200 Non Fibered Roof Coating or Mule -Hide 111 Non-Fibrated Roof Coating; >y PG300 Flbered Roof Coating or Mule -Hide 102 Fibrated Roof Coating; D PG600 Non-Fibered Aluminum Roof Coating or Mule -Hide 416 Standard Non-Fibrated Aluminum Roof Coating; > PG650 Flbered Aluminum Roof Coating or Mule -Hide 406 Standard Fibrated Aluminum Roof Coating; PG700 White Reflective Roof Coating; ➢ PG800 Non-Flbered Asphalt Emulsion Roof Coating or Mule -Hide 311 Emulsion Non-Flbrated; D PG850 Flbered Asphalt Emulsion Roof Coating or Mule -Hide 301 Emulsion Fibrated; > Polyplus 60 Premium Non-Flbered Aluminum Roof Coating or Mule -Hide 410 Premium Non-Fibrated Aluminum Roof Coating; Polyplus.65 Premium Fibered Aluminum Roof Coating or Mule -Hide 401 Premium Fibrated Aluminum Roof Coating; Y Polybrlte 70 White Elastomerlc Roof Coating. 15. The following represent priming requirements for gypsum -based coverboards; Y DensDeck and DensDeck Prime shall be fleld-primed with PG100 prior to self -adhering or torch -applied membrane application. No priming Is required for hot -asphalt membrane applications. i SECUROCK Gypsum -Fiber Roof Board or DensDeck DuraGuard do not require field priming for any membrane application. 16, "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R10 for FL1654-1112 Certificate of Authorization #9503 Revision 10: 08/21/2013 Prepared by; Robert Nieminen, PE-59166 Appendix 1, Page 3 of 31 TE;o q 06ed IT xlpuaddtl ETOZ/TZ/80 :OT u01sln9a ZT'd-459TId Jo; OT'd-80'ZO'06Md 7Jodaa uopenlen3 99T6S-3d 'uaulwalN :pagoa :Aq paJedaJd £OS6# uolaezlJoylntl;o aleollpso 02131Aaluljl a/q/p 'Jll 'u6lsaa pue piesswd JolJa4x3 'o'o pul E-AEMN3 sMoJ Jaauao slleu >lueys sMans B# HdSO pJeog -L sMoJ Jo EVJ paJa66eas 6up Jelnuue ql!m '7•o y0ul-g tll-ddtl tltl-S9S yy -SOS -W Jo ;ood Jaglj-wnsdAg Jaualse; xeW-il1nW gJ Plal4S 'paoeds Allenba •e6 ZT Alod asego;sel3 Jo slleu uowwoo P8 4aIM '0'0 0.09- � tll-S9S Jo tltl-dg Jo OZ-dD NJodnJ3S JO awlJd , dole ydSO , -H Pl914S , Jno; ul 0 o y;jM sdeo Jo asegoTse13 you!-ti payoe;le S-M 'tltl-S9S (Ieuolad0) tltl-d9 '00590 �loaasuad '�loaasua® -W Jo OZ -H III y0ul-9 pue ul; Ja;awelp sueds youl-bZ , SI-a 40u1-SZ'O 'ulW � -bJ 00S80 'II weod0tl del youl-y 4?ul-B/S xew le pooMAld 5I-a youl-Z 'ulW ul '0•0 40U1-9 -T e6 ZE 40ul-ZE/6T *ulW tll oslAlod sMOJ Jaauao paJa66els speu )lueys 6up Jelnuue SL# Stllgdtlg sMajos B# 4a1M oo 4Jul- . g tll -ddtl J0 -ddtl J0 tll pJeog dooa Jaqld-wnsdAg 68ZTJ , paoeds e6 TT Jo aseg sselg Jo slleu uowwoo 0109- tll-S9S -S9S 'VS tlS tlH >IJObno3S aw1Jd tlH WISV Allenba 441M sdeo oNwel'8Z Aid-ewJad Pe yl!M 1010 b-M 'VS-ddb' -SOS aJow -S8S )loa0sua4 >l3aclsuaO 'panoJddy 'DDJ4; ul 0.0 ul; Ja3awelp WC'ase9 gW auo;saal3 youl-{, payoeale VS-Sas Jo auo 4oul-SZ'0 'u!W Jgd 4oul-8 pue 40u1-8/ 'asegselg paalu!eaJaJ sueds youl-bZ (ILuolldp) (leuolad0) del 4Jul-b e6 'aseg ZE)ssel6Alod •xew le pooMAld ul 'd'o 4oul-8 -T ZE 40U!-ZE/6T 'uIW uol;elnsul pad pJeogJagl3 A;lsuaa y6lH sMoJ Jaauao slleu sMaJOs 8# >lapopnJ;S 4oul-S'0 oslAlod paaa66els llueys 6ulJ Jelnuue SL# S`dl9dtlg 4l!M '0'0 40U1-9 tll-ddtl tltl-S8S tltl 'ulw Jo (snoaua6owoy) 68ZTJ paoeds 'e6IT Jo aseg sselg Jo speu uowwoo 0109- tll-S9S Jo tltl-d9 -SOS tlH pJeog o0sad tlH WlSV Allenba 4aIM sdeo o>lwel'8Z Ald-ewJad p8 yalM •o•o f-M tltl-S95 (leuol4d0) Jo l 4ou! SG'0 *ulW pJeog panoJddy I Daly; ul o o ul; Jalawelp , W� aseg gW auo;saJld yowl-y payoe;le tltl-dg ;ooa Jagl3-wnsdAg 09:1 4aul-8 pue 4 'asegselg paalule:pao sueds youl-bZ >1oo,dnoas'awljd (lauolld0) del 4oul-ou!-8/5 b -T 'e6 ZE 'aseg ZE) ssel6Alod •xew le pooMAld )l0aasuaa'>l0aasuao ul •0.0 youl-s 40u1-Z£/6T 'ulW 4oul-sZ•0 'uIW sMoJ Jaauao slleu �lueys SL# Sb'l9dtlg tll tll pJeog oslAlod paJa66eas 6ulJ Jelnuue o aseg sselg slleu uowwoo -ddtl Jo -ddtl J0 tll ;ooa Jag13-wnsdAg 68ZTJ paoeds •e6 TT o)lwel 8Z Aid-ewnd loses P8 yalM •o•o S'Z5- tll-S85 -S9s VS tlS tlH NJObnJ3S lualJd tlH WISV Allenba yIIM sdeo WE SW auoasaald yowl-g payDeale Z-M 'VS-ddtl -393 aJow -SOS )loaasuad ')loaasuad panoJddy aaJyl ul 'o ° ula Jalawelp 'asegselg paaluleaJaO sueds youl-yZ tlS-S8S Jo auo youl-SZ'0 'uIW 0gd youl-B pue 40 aseg ZE) ssel6A10d xew;e pooMAld (leuoildo) (leuolado) del 40U1-b p!68/S I d ase o;se 3 A o q I 4ou!-ZE/6i 'u!W ul '0.0 40ul-8 -T ZE 'asegolsel3 uol;elnsul pJeogJagld A;IsuaO 451H 6iH sMoJ Jaauao slleu �lueys SL# Sb'l9dtlg >lapolonJ;s 4oul-5•o oslAlod paJa66e4s 6ulJ Jelnuue Jo aseg sselg slleu uowwoo tll-ddtl tltl-S9S tltl •ulw Jo (snoaua6owoy) 68ZTJ oe 'pads e6 TT o)lwel'8Z Aid-ewJad pg yalM •o•o S'Z9-'VI-SOS J0 VV-dg -585 tlH Pine 0osa3 'pJeog tlH WISH Allenba 'lyl 44lM sdeo WE loses SW auo4saJl3 'ase yowl-g p940e:pe T-M 'tltl-S9S (leuol4d0) Jo yowl-SG'0 'uIW 'panoJddy •o'aJ ; ul u!l Jalawelp se gIg paalu!eaJaO sueds youl-bZ tltl-dg ;ood Jagl3-wnsdAg J93 pul-8 pue youl-8/S 'aseg ZE)ssel6Alod •xew le pooMAld monnJ3s'awlJd (leuol4d0) del 4oul-b I,e6 'Alod asego4sel3 4oul-ZE/61 'ulW )loaasuaa 51080suaa ul ,0-0 youl-8 -T ZE 'asego4sel3 40ul-SZ10 •uIW (dsd) 2 Aid aseg 40MV adAi 40844V I adAl 43V ua;sed 1 adAi (T a;ON aaS) ON daW 31300 wa;sAS aanoJ;ooa uol;elnsul dai uoS;einsuI aseg 40849 J043UV Zl3A0:) d00M a3aN09'NOI1VIf1SNI a3aN09'133HSMOH:)NV a3HOV11V A-IIV:)INVH:)3W :Z-V 3dA1 W31SA8 0.40-MV31) d001M NO NOmmigNOD M3N — SH030 aOOM :T-VT 319V1 01101 JI.LINib� \I TRINITY J ERD TABLE 1A-1: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover MDP No. (See Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap (psf) Min. 19/32-Inch 32 ga., 1- 6-inch o.c. in Min. 2-Inch D-IS, plywood at max. 5/8-inch 4-inch lap ACFoam II OB500, CR- D-IS (Optional) SBS-SA 24-Inch spans attached 4-inch Elastobase or diameter tin and 6-inch o.c. In four, III, H- Shield H- 20 or M- (Optional) Additional OB500 SBS- One or more SBS- APP-SA, W-6 O.C.with 8d Elastobase Poly caps with equally Shield CG, OSFA, atop layers of base CR-20 SA SASBS- SBS-TA -60.0 common nails or 12 ga. spaced, Multi -Max fastener insulation or M- , TA or APP- or APP- 6-Inch o.c. with annular ring staggered FA3 or rows 7- OSFA TA TA #8 screws shank nails center rows ENRGY-3 inch o.c. Exterior Research and Design, LLC, d/b/a TrinityjERD Evaluation Report P9290.02.08-R10 for FL1654-R12 Certificate of Authorization #9503 Revision 10: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 5 of 31 QOTRINITYIERD TABLE 1A-2: WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover MOP Type Fasten Attach Type Attach - Type Attach Base Ply Cap No. (See Note 1) (psf) Min. 19/32- Elastobase OMG Fiat Bottom PI®tes 12-Inch O.C. Min. 0.25-Inch DensDeck, Inch plywood Elastobase Poly, (square) with In 4-Inch (Optional) DensDeck Prime, max. Polyglass G2 Base, Roofgrlp lap and tin FBC SECUROCK Gypsum - spans Inch spans In CertalnTeed Dekfast Hex ex Inch o.c. in Approved, Fiber Roof Board ,Min. BP -AA or (Optional) SBS-AA , W-7 attached 6- Glasbase, Firestone with Dekfast two, equally ASTM C1289, HA 0.75-inch Fesco Board HA SBS-AA BP -AA or SBS-TA, -52.5 Inch o.c, with MB Base, IM #14 or spaced, type II (homogeneous) or min. SBS-AA APP-TA 8d common Derma -Ply 28, Tamko Glass Base TruFast MP-3 staggered polyiso- cyanurate 0.5-Inch Structodek High Density Fiberboard Roof nails or AFGLAS #75 or GAF with TruFast center rows Insulation HD Elastobase, OMG Flat Min. 19/32- Elastobase Poly, Bottom Plates 12-Inch o.c. (optional) Inch plywood Polyglass G2 Base, (square) with In 4-Inch FBC Min. 0.25-inch (Optional) SBS-SA, at max. 24- CertainTeed Roofgrlp #14, lap and 12- Approved, DensDeck, DensDeck One or APP-SA, W-8 Inch spans attached 6- Glasbase Firestone Dekfast Hex with Dekfast Inch o.c. in two, equally ASTM C1289 HA Prime, SECUROCK HA SBS-SA more SBS- SA, SBS- SBS-TA -52.5 Inch o.c. with MB Base, ]M *14 or spaced, type II Gypsum -Fiber Roof TA or APP or APP- Bd common Derma-Pl' y 28, TruFast MP-3 staggered Polylso Board TA TA nails Tamko Glass Base with TruFast center rows cyanurate or GAFGLAS #75 HD Min. 19/32- Inch plywood 12-Inch o.c. (Optional) Min. 0.25-inch DensDeck, at max. 24- In 4-Inch FBC DensDeck Prime Inch spans OMG Flat lap and 12- SECUROCK Gypsum - (Optional) SBS-AA, W-9 attached 4- Elastobase or Bottom Plates Inch o.c. In ASTM C1289 HA 0.75-Inch Fesco Board HA BP -AA or BP -AA or SBS-TA -60.0 Inch with Elastobase Poly (square) with two, equally type II (homogeneous) or min. SBS-AA SBS-AA B APP-TA ed common Roofgrlp #12 spaced, polyiso- 0.5-Inch Structodek High nails or 6-Inch staggered 99 cyanurate Density Fiberboard Roof o.c. with #8 center rows Insulation screws Min. 19/32- Inch plywood 12-Inch o.c. (Optional) at max. 24- In 4-Inch FBC Min. 0.25-inch (Optional) SBS-SA, Inch spans OMG Flat lap and 12- Approved DensDeck DensDeck One or APP-SA, W-10 attached 4- Elastobase or Bottom Plates Inch o.c. In ASTM C1289, HA Prime, SECUROCK HA SBS-SA more SBS- SBS-TA -60.0 Inch o.c. with Elastobase Poly (square) with two, equally type.II Gypsum -Fiber Roof SA SBS- or APP- 8d common Roofgrlp #12 spaced, polyiso- Board TA or APP- TA nalls or 6-Inch staggered cyanurate TA o.c, with #8 center rows screws Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-1110 for FL1654-R12 Certificate of Authorization #9503 Revision 10: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 6 of 31 Q'�TRINITYJERD TABLE iB: WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck (See Not® 1) (Psf) Type Fasten Attach Type Attach Base Ply Cap Min. 19/32-Inch Min. 0.75-Inch Feseo plywood at max. 24- Min. 1.5-Inch Dekfast Hex with Board (homogeneous) (Optional If (Optional If using AA SBS-AA, W-11 Inch spans attached 6- ENRGY 3, H- Dekfast #12 or 1 per 1.33 ft p or min. 0.5-inch HA using AA Base) One or more SBS-TA, -52.5 Inch with Bd Shield or TruFast MP-3 with Structodek High Ply) BP -AA, BP -AA, SBS-AA, APP-TA commoonn Halls Polytherm TruFast DP Density Fiberboard SBS-AA SBS-TA or APP-TA Roof Insulation Min. 19/32-Inch Min. 0.75-inch Fesco plywood at max, 24- Min. 1.5-inch Dekfast Hex with Board (homogeneous) (Optional if (Optional if using AA SBS-AA, W-12 Inch spans attached 4- ENRGY 3, H- Dekfast #12 or 1 per 1.33 ft 2 or min. 0.5-inch HA using AA Base) One or more SBS-TA, -60.0 Inch o.c, with 8d Shield or TruFost MP-3 with Structodek High Ply) BP -AA, BP -AA, SBS-AA, APP-TA common nails or 6-Inch Polytherm TruPost DP Density Fiberboard SBS-AA SBS-TA or APP-TA o.c, with #8 screws Roof Insulation TABLE 1C: WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Deck (See Note i) Base Insulation Top Insulation Layer Roof Cover pgpp Type Fasten Attach Base Ply Cap No. Layer (psf) Min. 19/32-Inch wood I plywood (Optional) ) Min. 0.5-Inch Structodek High Density Fiberboard Roof Insulation or Dekfast Galvalume (Optional If (Optional if using AA SBS-AA, W-13 at max. 24-Inch spans attached 6-Inch o.c. with One or more layers, any combination, min. 0.25-Inch DensDeck, DensDeck Steel Hex with 1 per 1.33 ft y using AA Ply) BP -AA, Base) One or m ore BP -AA, SBS-AA, SBS-TA, -52.5 Bd common nails loose laid Prime or SECUROCK Gypsum -Fiber Dekfast #12 DP SBS-AA SBS-TA or APP-TA APP-TA Roof Board Min. 19/32-Inch plywood (Optional) Min. 0.5-Inch Structodek High Density Fiberboard Roof Insulation or Dekfast Galvalume (Optional If (Optional If using SBS-AA, W-14 at max. 24-Inch spans One or more layers, min. 0.25•Inch DensDeck, DensDeck Steel Hex with 1 per a using more Base) One a SBS-TA, -67.5 attached 4-Inch o.c. with any combination, Prime or SECUROCK Gypsum -Fiber Dekfast #12 DP 1.33 ft P- Ply) BP -AA, - BP -AA, SBS-AA, APP TA 8d common nails loose laid Roof Board SBS-AA SBS-TA or APP-TA Min. 19/32-inch plywood (Optional) h High Min. 0.5-Inch Structodek(Optional Density Fiberboard Roof Insulation or Dekfast Galvalume If (Optional if using AA SBS-AA, W-15 at max, 24-Inch spans p One or more layers, y min. 0.25-Inch DensDeck, DensDeck Steel Hex with 1 per 1.33 ft2 using AA BP Base) One or more BP SBS-AA, SBS-TA, -82.5 attached 6-Inch o.e. with any combination, Prime or SECUROCK Gypsum -Fiber Dekfast #12 DP PI y) -AA, -AA APP-TA #8 screws loose laid Roof Board SBS-AA SBS-TA or APP-TA Min, 19/32-Inch plywood (Optional) l l t G Dekfast avaume De Steel Hex with (Optional) One or SBS-SA, W-16 at max. 24-Inch spans One or more layers, Min. 1.5-Inch ENRGY 3 H-Shield or Dekfast.#12 DP or 1 per 1,33 SBS-SA more SBS-SA, SBS- APP-SA, SBS-TA -82.5 attached 6-Inch o.c. with any combination, Polytherm TruFast MP-3 with ft2 TA or APP-TA or #8 straws loose laid TruFast DP APP-TA Exterior Research and Design, LLC, d/b/a TrinitylERD Evaluation Report P9290.02.08-R10 for FL1654-1112 Certificate of Authorization #9503 Revision 10: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 7 of 31 F)o \I I RINITY I ERD TABLE 1113: WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Insulation Layer(s) Base Sheet Roof Cover Npp No. Deck (See Not© 1) Oaf) Type Attach Base Fasten Attach Ply Cap Elastobase, Elastobase Poly, OMG Flat Bottom Plates Min. 19/32-Inch plywood One or Polyglass G2 Base, ri f with R e) uarwoogp (square) 12-Inch o.c. In 4-Inch (Optional) One or SBS-AA, W-17 at max. 24-Inch spans more Prelim. CertalnTeed Glasbase *14 Dekfast Hex with lap and 12-inch o.c. In more BP -AA SBS- SBS-TA -52.5 attached 6-Inch o.c, with layers, any Attached Firestone MB Base, ]M Dekfast #14 or TruFast two, equally spaced, AA, SBS-TA or ' APP-TA 8d common nails combination Perma=Ply 28, Tamko Glass MP-3 with TruFast HD staggered center rows APP-TA Base or GAFGLAS #75 Min. 19/32-Inch plywood One or OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. in 4-inch One or more SBS- SBS-SA, W-18 at max. 24-Inch spans more Prelim. Elastobase or Elastobase #14 Dekfast Hex with lap and 12-Inch o.c. In SA SBS-TA or APP-SA, -52.5 attached 6-Inch o.c, with layers, any Attached Poly with poly top surface Dekfast #14 or TruFast two, equally spaced, APP-TA SBS-TA or 8d common nails combination MP-3 with TruFast HD staggered center rows APP-TA Min. 19/32-Inch plywood at max. 24-Inch spans One or 12-Inch o.c. In 4-Inch (Optional) One or SBS-AA, W-19 attached 4-Inch o.c. with more Prelim. Elastobase or Elastobase OMG Flat Bottom Plates lap and 12-Inch o.c. In more BP -AA, SBS- SBS-TA, -60.0 ed common Halls or 6- layers, any Attached Poly (square) with Roofgrip #12 two, equally spaced, AA, SBS-TA or gpp_TA Inch o.c. with #8 screws combination staggered center rows APP-TA Min. 19/32-Inch plywood at max. 24-Inch spans One or 12-inch o.c. in 4-Inch One or more SBS- SBS-SA, W-20 attached 4-Inch o.c. with more Prelim. Elastobase or Elastobase OMG Flat Bottom Plates lap and 12-Inch o.c. In SA SBS-TA or APP-SA, -00.0 8d common nalls or 6 layers, any Attached Poly with poly top surface (square) with Roofgrip #12 two, equally spaced, APP-TA SBS-TA or Inch o.c, with #8 screws combination staggered center rows APP-TA Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-R10 for FL1654-R12 Certificate of Authorization #9303 Revision 10: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 8 of 31 \I I RINITY I ERD TABLE 1E: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) " SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck (See Note 1) Base Sheet Roof Cover IdDP Base Fasten Attach Ply Cap No. (Psf) thick Minexterior exterior grade plywood for grade 9-Inch o.c, at 2-Inch lap and (Optional) BP -AA, SBS-AA, W-21 attached per Code to meet Elastobas® Simplex MAXX Cap 18-Inch o.c. in two, equally SBS-AA, SBS-TA or SBS-TA or -45.0* pressure requirements, spaced, staggered center rows APP-TA APP-TA_ Min, 15/32inch thick exterior grade plywood 9-inch o,c, at 2-inch lap and (Optional) BP -AA, SBS-AA, W-22 attached per Code to meet Elastobas0 Simplex MAXX Cap 12-inch o.c. in two, equally SBS-AA, SBS-TA or SBS-TA or -52.5 pressure requirements. spaced, staggered center rows APP-TA APP-TA Min. 19/32-Inch plywood at max. 24-Inch spans Elastobase, Elastobase Poly, Polyglass G2 Base, CertalnTeed Glasbase, 3Z ga., 1-5/8-Inch diameter tin 8-inch o,c. in 4-inch lap and 8- (Optional) One or more BP -AA, SBS SBS-AA, W-23 attached 6-Inch o,c, with Firestone Base, JM Ply caps with it ga, annular ring shank nails Inch o,c, in three, equally spaced, staggered center rows AA, SBS-TA or APP- SBS-TA, APP-TA .52.5 8d common Halls Gloss GAFGLPermaAS Tamko Glass Base or GAFGLAS #75 5 TA Min, 19/32-Inch plywood at max, 24-Inch spans Elastobasd or Elastobase Poly with 32 ga., 1-5/8-Inch diameter tin 8-Inch o,c, In 4-Inch lap and 8- (Optional) One or SBS-SA, APP-SA W-24 attached 6-Inch o,c, with poly top surface caps with it ga, annular ring Inch o,c, In three, equally more SBS-SA, SBS- SBS-TA or -52.5 8d common nails shank nails spaced, staggered center rows TA or APP-TA APP-TA Min. 19/32-Inch plywood Elastobase, Elastobase Poly, Polyglass OMG Flat Bottom Plates (square) 12-Inch o,c. in lap and (Optional) One or SBS-AA, W-25 at max. 24-Inch spans G2 Base, CertalnTeed Glasbase, with Roofgrlp #14, Dekfast Hex 12-Inch o,c. in two, equally two, a more BP -AA, SBS- SBS-TA, -52,5 attached 6-Inch o,c. with Firestone MB Base, JM Perma-Ply'28, with Dekfast #14 or TruFast MP- spaced, staggered center rows AA SBS-TA or APP- APP-TA 8d common nails Tamko Glass Base or GAFGLAS #75 3 with TruFast HD TA' Min, 19/32-Inch plywood at max, 24-Inch spans . Elastobaso or Elastobase Poly with I OMG Flat Bottom Plates (squaro) with Roofgrlp #14 Dekfast Hex 12-Inch o.c. In 4-Inch lap and One or more SBS- SBS-SA, APP-SA W-26 attached 6-Inch o.c, with poly top surface with Dekfast #14 or TruFast MP- 12-Inch o,c. in two, equally spaced, staggered center rows SA, SBS-TA or APP- TA SBS-TA or -52" 8d common nails 3 with TruFast HD APP-TA Min. 15/32-Inch thick exterlor grade plywood Original Simplex Cap Nails (1- Inch metal hand diameter, 11 6-Inch o.c. at 3-Inch lap and 6- (Optional) SBS-SA, SBS-SA, W-27 attached per Code to meet Polyglass APP Base gauge x min, 1.25-Inch long Inch o.c. in four, equally spaced, staggered center rows APP-SA or APP-TA APP-SA or APP-TA -52.5 pressure requirements. annular grooved shank) Min. 15/32-Inch thick Original Simplex Cap Nails (1- 6-Inch o,c, at 3-inch lap and 6- W-28 exterior grade plywood attached per Code to meet Elastobas® (with poly top surface) Inch metal head diameter, r11 gauge x min. 1,25-Inch long Inch o,c, In four, equally (Optional) SBS-SA or APP-SA SBS-SA or APP-SA -52.5 pressure requirements. annular grooved shank) spaced, staggered center rows Min, 15/32-Inch thick exterior grade plywood Original Simplex Cap Nails (1- Inch metal head diameter, 6-inch o,c. at 3-Inch lap and 6- (Optional) BP -AA, SBS-AA, W-29 attached per Code to meet Elastobas® (with sand top surface) gauge x min, slong g Inch o,c. In four, equally SBS-AA, SBS-TA or SBS-TA or -52.5 pressure requirements, annular grooveedd shank) spaced, staggered center rows APP-TA APP-TA Min. 19/32-Inch plywood at max, 24-Inch spans Elastobase Elastobase Poly, Polyglass r Y Yg G2 Base CertainTeed Glasbase ' ' 3Z ga., 1-5/8-Inch diameter tin 8-Inch o,c, In 4-Inch lap and 8- (Optional) One S more BP -AA, SBS- SBS-AA, W-30 attached 4-Inch o.c. with 8d common nails or 6-inch Firestone MB Base, JM Perma-Ply 28, caps with ii ga, annular ring shank nails inch o,c. In three, equally spaced, staggered center rows AA, SBS-TA or APP- SBS-TA, APP-TA -60,0 o.c. with #8 screws Tamko Glass Base or GAFGLAS #75 TA exterior Researctl ana L)esign, LLC. a/b/a TrinitylERD Evaluation Report P9290.02.08-R10 for FL1654-R12 Certificate of Authorization #9503 Revision 10: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 9 of 31 F)o \,l TRINITY ERD TABLE 1E: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck (See Note i) - Base Sheet Roof Cover MDP Baso Fasten Attach Ply Cap No. (Psf) Min. 19/32-Inch plywood SBS-SA, at max. 24-Inch spans Elastobase or Elastobase Poly with 32 ga., 1-5/8-Inch diameter tin 8-Inch o.c. In 4-Inch lap and 8- (Optional) One or APP-SA, W-31 attached 4-Inch o.c, with Poly top surface caps with 11 ga, annular ring Inch o.c. In three, equally more SBS-SA, SBS- SBS-TA-or -60.0 8d common nails or 6-Inch shank nails spaced, staggered center rows TA or APP-TA APP-TA o.c. with #8 screws Min. 19/32-Inch plywood (Optional) One or at max. 24-Inch spans OMG Flat Bottom Plates (square) 12-Inch o.c. in 4-Inch lap and more BP -AA, SBS- SBS-AA, W-32 attached 4-Inch o.c. with Elastobase or Elastobase Poly with Roofgrlp #12 12-Inch o,c. In two, equally AA, SBS-TA or APP- SBS-TA, -60.0 8d common nails or 6-Inch spaced, staggered center rows TA APP-TA o.c. with #8 screws Min. 19/32-Inch plywood SBS-SA, at max. 24-Inch spans Elastobase or Elastobase Poly with OMG Flat Bottom Plates (square) 12-Inch o.c. In 4-Inch lap and One or more SBS- APP-SA, W-33 attached 4-Inch o.c, with poly top surface with Roofgrlp #12 12-Inch o.c. In two, equally SA, SBS-TA or APP- SBS-TA or -60.0 8d common nails or 6-Inch spaced, staggered center rows TA APP-TA O.C. with #8 screws Min. 15/32-Inch thick exterior grade plywood 6-Inch o.c. at 2-Inch lap and 6- (Optional) BP -AA, SBS-AA, W-34 attached per Code to meet Elastobase Simplex MAXX Cap Inch o.c. In two, equally SBS-AA, SBS-TA or SBS-TA or -90.0 pressure requirements. spaced, staggered center rows APP-TA APP-TA Min. 15/32-Inch thick OMG #12 Standard Roofgrlp or attaessuhre grade plywood OMG *14 Heavy Duty (min. 1- 6-Inch o.c, at 4-Inch lap and 6- W-39 pre per Code to meet Polygless APP Base 5/8-Inch long) with OMG 3" Inch mc. In three, equally (Optional) APP-TA APP-TA -90.0 pressure requirements. Round Metal Plates or OMG Flat spaced, staggered center rows Bottom Metal Plates Min. 15/32-Inch thick OMG #12 Standard Roofgrlp or exterior grade plywood OMG #14 Heavy Duty (min. 1- 6-Inch o.c, at 4-Inch lap and 6- (Optional) BP -AA, SBS-AA, W-36 attachedElastobase per Code to meet (with sane top surface) 5/8-Inch long) with OMG 3" Inch o.c. In three, equally SBS-AA, SBS-TA or SBS-TA or -90.0 prerequirements. pressure Round Metal Plates or OMG Flat spaced, staggered center rows APP-TA APP-TA Bottom Metal Plates Min. Inch thick lor grade plywood exterior Trufast #12 DP or Trufast #14 6-Inch o.c, at 4-Inch lap and 6- (Optional) BP -AA or W-37 attached per Code to meet Elastobase (with sand top surface) HD (min. 1-5/8-Inch long) with Inch o.c. In three, equally SBS-AA SBS-AA -90.0 pressure requirements. Trufast 3" Metal Insulation Plates spaced, staggered center rows Min. 19/32-Inch plywood at max. 24-Inch spans Elastobase or Elastobase Poly with 32 ga., 1-5/8-Inch diameter tin 4-Inch o.c. In 4-Inch lap and 4- (Optional) One or SBS-SA, APP-SA - W-38 attached 6-Inch o.c, with poly top surface caps with it ga. annular ring Inch o,c. In four, equally more SBS-SA, SBS- SBS-TA or -97.5 #8 screws shank nails, spaced, staggered center rows TA or APP-TA APP-TA Min. 15/32-Inch thick exterlor grade plywood 6-Inch o.c, at 2-inch lap and 6- (Optional) BP -AA, SBS-AA, W-39 attached per Code to meet Elastobase Simplex MAXX Cap Inch o.c, in three, equally SBS-AA, SBS-TA or SBS-TA or -105.0 pressure requirements. spaced, staggered center rows APP-TA APP-TA Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-1110 for FL1654-R12 Certificate of Authorization #9503 Revision 10: 08/21/2013 Prepared by; Robert Nieminen, PE-59166 Appendix 1, Page 10 of 31 (_)o ,,I TRINITY I ERD TABLE 1E: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Base Sheet Roof Cover MDP No. Deck (See Note 1) Ba8® Fasten Attach Ply Cap- (psf) Min. 19/32-Inch plywood et max. 24-Inch spans 32 ga., 1-5/8-Inch diameter tin 6-Inch o.c, in 4-Inch lap and 6- (Optional) One or more BP -AA SBS- SBS-AA,, W-40 attached 6-Inch o.e, with Elastobas® or Elastobase Poly caps with 11 ga. annular ring Inch o.c. In four, equally AA, SBS-TA or APP- SBS-TA; -112.5 #8 screws shank nails spaced, staggered center rows TA APP-TA Min. 19/32-Inch plywood 32 ga., 1-5/8-Inch diameter tin (Optional) One or more SBS-SA (no SBS-SA, W-41 at max. 24-Inch spans Elastobas® or Elastobase Poly with caps with 11 ga. annular ring shank nails. Note: Tln caps are 6-Inch o.c. In 4-Inch lap and b- Inch o.c. In four, equally Elastoflex SA V Base APP-SA, -112.5 attached 6-Inch o.c, with poly top surface to be primed with PG100 or spaced, staggered center rows or Elastoflex FR SBS-TA or #8 screws ASTM D41 primer. Base), SBS-TA orr APP-TA APP-TA Min. 15/32-Inch thick OMG #12 Standard Roofgrlp or exterior grade plywood OMG #14 Heavy Duty (min. 1- 6-Inch o.c, at 4-Inch lap and 6- W-42 attached per Code to meet Polyglass APP Base 5/8-Inch long) with OMG 3" Inch o.c. In five, equally (Optional) APP-TA APP-TA -120.0 pressure requirements. Round Metal Plates or OMG Flat spaced, staggered center rows Bottom Metal Plates Min. 15/32-Inch thick OMG #12 Standard Roofgrlp or exterior grade plywood OMG #14 Heavy Duty (min. 1- 6-Inch o.c, at 4-Inch lap and 6- (Optional) BP -AA, SBS-AA, W-43 attached per Cod® to meet Elastobase (with send top surface) 5/8-Inch long) with OMG 3" Inch o,c. In five, equally SBS-AA, SBS-TA or SBS-TA or -120.0 pressure requirements. Round Metal Plates or OMG Flat spaced, staggered canter rows APP-TA APP-TA Bottom Metal Plates Min. 15/32-Inch thick exterior grade plywood Trufast #12 DP or Trufast #14 6-Inch o.c, at 4-Inch lap and 6- (Optional) BP -AA or W-44 attached per Coda to meet Elastobase (with sand top surface) H® (min. 1.5/8-Inch long) with Inch o.c. In flue, equally SBS-AA SBS-AA -120.0 pressure requirements. Trufast 3" Metal Insulation Plates spaced, staggered center rows TABLE 1F: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER Roof Cover MDP System No. Deck (Sao Note 1) Primer 3oint Treatment Base Ply Cap (psf) Min. 19/32-Inch plywood at W-45 max. 24-Inch spans attached (Optional) PG100 Nona SBS-SA (Optional) SBS-SA, SBS-SA, APP-SA, -90.0 6-Inch o.c, with 8d ring shank SBS-TA or APP-TA SBS-TA or APP-TA nails Min. 15/32-Inch plywood at Plywood joints are covered with 4-Inch wide strips Elastoflex SA V (Optional) SBS-SA, SBS-SA, APP-SA, W-46 max. 24-Inch spans attached (Optional) PG100 of Elastoflex SA V Plus, rolled Into place to create Base or Elastoflex SBS-TA or APP-TA SBS-TA or APP-TA -97.5 6-Inch o.c. with #12 screws continuous bond. SA V FR Base Min. 15/32-Inch plywood at Plywood joints are covered with 4-Inch wide strips Elastoflex SA V Plus (Optional) SBS-SA, SBS-SA, APP-SA, W-47 max. 24-Inch spans attached (Optional) PG100 of Elastoflex SA V Plus, rolled Into place to create or Elastoflex SA V SBS-TA or APP-TA SBS-TA or APP-TA -135.0 6-Inch o.c. with #12 screws I I continuous bond. Plus FR Exterior Research and Design, LLC. d/b/a TrinityjERD Evaluation Report P9290.02.08-RSO for FL1654-R12 Certlficate of Authorization #9503 Revision 10: 08/21/2013 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 11 of 31