Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSALL APPLICAPLE INFP MUST BE COMPLETEI�FOR APPLICATION TO BE ACCEPTED Date: I� CANNED Permit Number: St. Lucie COunty Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-15S3 Fax: (772) 462-1578 Commercial Residential PERMIT APPLICATION FOR: T e "PROPOSED IIIVIPROVEMENT LOCATION:' Address: ISO SE Su-ex)[CLtv:k Legal Description: 1L �ry C,(Z ���Iz - �•'y } '-4 Property Tax ID #: �z-� I Q `" Sd - O I �'{ - CSC)®- �7 Lot No. Site Plan Name: Block No. Project Name: Setbacks Front Back: Right Side: Left Side: DETAI 'ED'DESCRI�PTION'0F WORK.,, %Lo0 _-C-tj 5 #' t-t S v rvlc-+ r-t l . C> o c 2 e.c. & ('c 0 k) J e 2 toy vvAe 1"A s I 1 Z `7 k1z.L, �Lloasc, f+ guA CONSTRUCTION INFORMATION: Additional work t0 e nertormed under this permit —check all that apply: 0HVAC 0 Gas Tank Gas Piping E]Shutters Q Windows/Doors Electric 0 Plumbing Sprinklers E]Generator Roof Total Sq. Ft of Construction: g2 SC . Ft. of First Floor: Cost of Construction: $ 9� 000 — utilities: Sewer [j Septic Building Height: O.wN ER/LESSEE: CONTRACTOR; Name vn 1in Name:'6e,% c:w "C Address: Company: e V _SL)&r City: J9S State: Addr s: i�r L SL�,.J 1�i i�lmOt2 e Zip Code: Fax: City: i_ G State: _� 1` �- Phone No. - C� Zip Code: $ L Fax. `?7� 3-$3rJ g E-Mail: Phone No. r Fill in fee simple Title Holder on next page ( if different E-Mail: from the Owner listed above) State or County License: S if value of construction is $2500 or more, a RECORDED Notice of Commencement is required. u SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable MORTGAGE COMPANY: _ Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording vour Notice of Commencement. dig. A -P" �7� 0 1/� Signatur of wne ge Lessee Signature of o ractor/License Holder STATE OF FLORIDA STATE OF FLORIDA COUNTY OF cCOUNTYOF JS ,,LyLc !e The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me this --& day of &—_ F t7 , 20 14 by this J& day of e T 2014 by o.k r1a WM1a"\t (Name of per �' dging) (Name of per n wledging ) (Signat f to ublic- State of Florida) (Sign of ry Public- State of Florida ) PersonallyKnown OR Produced Identification Personally Known OR Produced Identificati Y Type of Identificatio Produced No011 Type of Identificati n Produced / Commission No. ?_ZV3T �� 0; �S� a�pp�•. Commission No. / L Z"1 3�% ( �.' `'SZ 2019/9Fit% s Revised 07/15/2014 %Iqi ?.,.'•. ®,wBandad�� �: ���� . ti '•._Buda�etNo�.! ���Q REVIEWS FRONT //��9gy'p .... g ZCS11Q'PI j��� �� �' 1\01� 46PERVIS0R PLANS VEGETATION SEATURTLE A8yPUBuc, KMaN110itljt/E COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS 0*40 JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 3995361 OR BOOK 2 PAGE 750, Recorded 09/16/2014 at --' 18 AM Permit No. State of Florida County of St. Lude NOTICE OF COMMENCEMENT Tax Folio No. 1u (2 . rya a I i I MOL4 The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following Information Is provided in this Notice of Commencement. Legal Description of Prop�ty� ( suet address if avai} hie): K. I,rrY line S' It IG (I 7 1eY y General description of Improvement: REROOF If the Lessee contracted for the Improvement: Name Address Interest In property: (/VkVL Name and address of fee simple titleholder (if different from Owner listed above): ContractorsNema: TREASURE COAST ROOFING Contractor Address: 1816 SW BILTMORE PSL,FL 34984 Phone Number: 772-370-9770 Surety (If applicable, a copy of the payment bond Is attached): Amount of bond: $ Name and address: Phone number: Lender Name: Phone Number: Lender's address: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section ]jIMI) (a)7 Florida Statutes: Name: Phone Number: Address: In addition to himself or herself, Owner designates of Uenor's Notice as provided In Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy of the Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the fads stated therein are true to the best of my k col and belief, ( 1Zn!r ure nor or Lessee, or Owner's or Lessee's Authorized Officer/Director/Partner/Manager The Type, before me this f -L�gllbNll�j,/gY , 2C I `,•I Type ofthd]& �l .Jrusf;be) Party on behalf of whom Instrument was executed �= s g:t 's 3 t f f22434 f *= Personally known or produced Identification_ of Florida) Person ad Name of Notary Publir a .11 Type of Identification produced . to STATE O, FLORIDA ST. LUCIE COUNTY TIJIU Ie%7n nrnv, Malt(: ar-r I U [U lit 10/14/2014 8:25 All FAX 7723433308 Tcroofing 0001/0001 �•.��. �rl -��1�-tx7 cur.. �� ,� eF�L:�I�j{ FCjtic ��}'�f��.*�'''•,�.y+ �(ll�;hi:! iJ;:��~, �:1 .f�rit.d ;5...,..-,W Re: Permit# Igocf L231 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fast: 772-462-6443 ROOF INSPECTION AFI:I[�AVIT It a\'Wy.z Clicensed as a(n)I"ontra r*/Engineer/Architect (Please print name & circle iicen a type) F" Building Inspector *General, Building, Residential or Roofing contractor or any individuol certefied under 499 F.S. to make such an inspedion. On or about I did personally inspect the roof deck nailing (Date work at: C (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based an 553.844 F.S_) KA'1W -- 5i a ur eal STATE OF FLORIDA CRUNTYOF SI.Lk�.T sworn to and subscribed before me this by V 4-krx r.j Notary Public, State o f Signature of Notary:—� Commission Number: •� En 01/19/203A /4y License # RECEIVED OCT 1.42014 1p—e_. 20—L 14 or who has produced Florida Building Code Online Page 1 of 3 11� fir" Florida De-parUnento Busines Professi al BCIS Home Ia9 M User 11e961,.tlpn HotTopics Submit Surcharge I Stats & Face Publications ! �Qprova1 Vi4�� k Usebl r FBC St 0 BCIS Slte Map Unks Search Regulation Product Approval Menu > Pmdmt or Application Search > Application LIA > Application Deell - FL fF A,,Iicatl,n Type Code Version Application Status FL32966-R3 Revision 2010 Approved Comments Archived Product Manufacturer IM Metals (Innovative Distribution LLC) Address/Phppp/Email 1505 QM Road Cocoa, FL 32926 (321) 639-1537 tonyojmmetals.com 3 T� UIL ING DIVISION UC Authorized Sienature James Buckner SnT� L'`a C jlmmy@cbucklnc.ad REV W1 D FOR COINLUL CE , REVIEWED BY Technical Representative � _ '• Address/Phone/Emall DATE ST BE I�PT ON JOB PLANS AND PERMIT Quality Assurance Representative OR NO LNSPECTION WILL BE MADE. Address/Phone/Emall Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Renort from a Florida Registered Architect or a Ueensed Florida professional Engineer Evaluation Report - Hardcopy Received Florida Enofneer or Architect Name who developed the Evaluation Report lames L Bucker, P.E.@ CBUCK Engineering Florida I Icense, PE-31242 Quality Assurance Entity K stone Certifications, Inc. Quality Assurance Contract Expiration Date 12/31/2016 Validated By Steven M. Udch, PE J Validation Checklist - Hardcopy Received r'artinrate of Independence Referenced Standard and Year (of Standard) Equlvalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved 2 i summary of Products 3 3 FL12966 R3 COI CertOflndeo Ddf StpDda[d Yea[ TAS 125 2003 UL 1897 2004 UL 580 2006 Florida Licensed Profejslaaai Eng1n= or Architect FL12966 R3 Eauly Test Standard Eauiv.odf Method 1 Option D 04/24/2012 04/25/2012 05/01/2012 06/11/2012 Trust Rating a Not Yet Rated http://www.floridabuilding.orglpr/pr app_dtl.aspx?param=wGEVXQwtDgv4i95T%2bUQ... 9/16/2014 Florida Building Code Online Page 2 of 3 FL 3 Model, Number or Name Description 12966.1 Ol - "JM Nailstrip" Fastener Strip Roof Panel - 0.032" Aluminum, 12" Width, Attached to 15/32" Plywood Deck w/Clitional Limits of Use Installation Instructions Approved for use In HVHZ: No FL12966 R3 II Ol NailstrlD Alum Wood Deck EVALREPORT.odf Approved for use outside HVHZ: Yes Verified By: James L Buckner, P.E. @ CBUCK, Inc- P.E. #31242 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-69.25 Evaluation Reports Other. Refer to Evaluation Report for Umltatlons and Conditions of Use. Refer to FL12966 R3 AE O1 Nallstrio Alum WoodCleck EVALREPORT.Dcl manufacturers Installation Instructions MajuNlemerdal guide. Created by Independent Third Party: Yes 12966.2 02 - "JM Nailstrip" Fastener Ship Roof Panel - 26 Gauge Steel, 16" Width, Attached to 15/32" Plywood Deck w/O tlonal Rigid Insulation Limits of Use Installation Instructions Approved for use In HVHZ: No FL12965 R3 II 02 Nalistrio Steel WoodDeck EVAIREPORT odf Approved for use outside HVHZ:- Yes Verified By: James L Buckner, P.E. @ CBUCK, Inc P.E. #31242 . Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-121.75 Evaluation Reports Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to FL12966 R3 AE 02 Nailstrlo Steel WoodDeck EVALREPOR7 odf manufacturers installation Instructions as a supplemental guide. Created by Independent Third Party: Yes 12966.3 03 - "IM 1.75 Snap -Lock' Snap -Lock Roof Panel - 0.032" Aluminum, 18" Width, Attached to 15/32" Plywood Deck w/O tlonal Rigid Insulation Limits of Use Installation Instructions Approved for use In HVHZ: No FL12966 R3 II 03 1.75SMpLack Alum WoodDeck EVALREPORT,odf Approved for use outside HVHZ: Yes Verified By: James L Buckner, P.E. @ CBLK:K, Inc P.E. #31242 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-91.75 Evaluation Reports Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to FL12966 R3 AE 03 1.75Snaoinck Alum WoodDeck EVALREPORT.odf manufacturers Installation Instructions as a supplemental guide. Created by Independent Third Party: Yes 12966.4 04 -'7M 1.75 Snap-LocK: Snap -Lock Roof Panel - 24 Gauge Steel, 18" Width, Attached to 15/32" Plywood Deck w/Optional Rigid Insulation Limits of Use Installation Instructions Approved for use In HVHZ: No FL12966 R3 II 04 1.755naoL.cck Steel WoodDeck EVALREPORT.odF Approved for use outside HVHZ: Yes Verified By: James L Buckner, P.E. @ CBUCK, Inc P.E. #31242 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-76.75 Evaluation Reports Other: Refer to Evaluation Report for LJmitations and Conditions of Ise. Refer to R12966 R3 AE 04 1.75Snaolock Steel WoodDeck EVALREPORT.Ddf manufacturers Installation Instructions as a su piemental guide. Created by Independent Third Party: Yes 12966.5 05 - "JM Rib" Lapped Roof Panel - 29 Gauge Steel, 36" Width, Attached to 15/32" Plywood Deck w/Optional Rigid Insulation Limits of Use Installation Instructions Approved for use in HVHZ: No FLJn66 R3 11 05 Rib Steel WoodDeck EVALREPORT.Ddf Approved for use outside HVHZ Ye, Verified By: James L Buckner, P.E. @ CBUCK, Inc P.E. #31242 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-69.25 Evaluation Reports Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to FL12965 R3 AE 05 Rib Steel WoodDeck EVALREPORT.odf I manufacturers installation Instructions as a supplemental guide. Created by Independent Third Party: Yes 12966.E O6 - "IM 5V Crimp" Lapped Roof Panel - 26 Gauge Steel, 24" Width, Attached to 15/32" Plywood Deck w/O tlonal Rig Id Insulation units of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-114.25 Other: Refer to Evaluation Report for Limitations and Conditions or Use. Refer to Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-159.25 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-137 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-106 Other: Refer to Evaluation Report for Lmitatlons and Conditions of Use. Refer to Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-120 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to nanufacturers Installation Instructions as a suoolemental auide. [nstallation Instroctions R.12966 R3 TI 06 IV WaodDeck EVALREPORT.Ddf Vedfied By: James L Buckner, P.E. @ CBUCK, Inc P.E.#31242 Created by Independent Third Party: Yes Valuation Reports FL12966 R3 AE 06 SV Wood(Jeck EVALREPORT.ndf Created by Independent Third Party: Yes itarding Seam Roof Panel - 24 Gauge Steel, 16" Width, Attached to ulth One -Piece Panel Clips w/Optional Rigid Insulation Installation Instructions F112966 R3 IT 07 1,5StandinaSeam WoodDeck EVALREPORT.gdf Verified By: James L Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Valuation Reports FL12966 R3 AE 07 LSStandinaSeam WoodDeck EVALREPORT.Dd Created by Independent Third Party: Yes apped Roof Panel - 24 Gauge Steel, 41-1/4" Width, Attached to IS/: Installation Instructions FL32966 R3 U D8 NordmanTlleOnl-2WoodDeck EVALREPORT.odf Verified By: James L Buckner, P.E. @ CBUCK, Inc P.E. 931242 Created by Independent Third Party: Yes Valuation Reports FL12966 R3 AE 08 NordmanTileOnl-2WoodDeck EVALREPORT odd Created by Independent Third Party: Yes apped Roof Panel - 24 Gauge Steel, 41-1/4" Width, Attached to 19/: :nstallation Instructions FI.12966 R3 II 09 NordmanTileOnS-BWoodDeck EVALREPORT odf Verified By. James L Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes :valuation Reports FL12966 R3 AE 09 NordmanTlleOn5-SWoodDeck EVALREPORT.DdI Created by Independent Third Party: Yes Wiped Roof Panel - 24 Gauge Steel, 41-1/4" Width, Attached to 22 :nstallation Instructions FL12966 R3 iI ]0 t=anTileOnSteelDeck EVALREPORT.0 Verified By: James L Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes . Limits of Use Installation Instructions Approved for use In HVHZ: No FL12966 R3 11 11 NordmanTile Alum0n5-8WoodDeck EVALREPORT.odF Approved for use outside HVHZ Yes Verified By: James L Buckner, P.E. @ CBUCK, Inc P.E. #31242 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-107 Evaluation Reports Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to R12966 R3 AE 11 NordmanTile Alum0n5-8WoodDeck EVALREPORT.Ddf manufacturers Installation Instructions as a supplemental guide. Created by Independent Third Party: Yes ia4 Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer• Coovrlaht 2007-2013 State of Florida. ;: Privacy Statement:: Acc ssibifity Statement:: RefundStatement Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a pubil-reconls reques4 do not send electronic mall 6h this entity. Instead, contact the office by phone or by traditional mail. If you have any questlons, please 000tct 850.487.1395.'P—..t to Section 455.275(3), Florida statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses a; d public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine If yo"are a likens£e._ rldd"r Cta'her 455, RS., please O click be s TfUst Kail ng < Pmdact Approval Accepts: a e „ Not Yet Rated flckidabuiltling.wg a2 http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv4i95T%2bUQ... 9/16/2014 Specialty Structural Eng1neer1nc2 Evaluation Report "JM 5V Crimp" Metal Roof Assembly Manufacturer: CBUCK, Inc. Certificate of Authorization #8064 Innovative Distribution, LLC d/b/a JM Metals 1505 Cox Road Cocoa, Florida 32926 321.639.1537 for Florida Product Approval # FL 12966.6 R3 Florida Building Code 2010 Per Rule 9N-3 Method: 1 D Category: Roofing Sub - Category: Metal Roofing Product: JM 5V Crimp. Roof Panel Material: Steel Panel Thickness: 26 gauge Panel Width: 24" Support: Wood Deck Prepared by: James L. Buckner, P.E., S.E.C.B. Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Diana Galloway Report No. 12-132-SV-59W-ER Date: 4/6/ 12 Contents: Evaluation Report Pages 1— 9 i James L. Buckner, P.E., SECB Florida P.E. # 31242 CBUCK, Inc. At -7-ett 1399 N. Killian Drive, Suite 4, West Palm Beach, Florida 33403 Phone: (561)491-9927 Fax: (561)491-9928 Website: www.cbuckinc.net CBUCK Engineering FL #: FL 12966.6-113 Date: 4/6/12 Report No.: 12-132-5V-S6w-ER Page 3 of 9 SpeclaltLj Structural Engineering CBUCK, Inc. Certificate of Authorization ##8064 Performance Standards: The product described herein has demonstrated compliance with: • UL580-06 — Test for Uplift Resistance of Roof Assemblies • UL 1897-04 — Uplift test for roof covering systems • TAS 125-03 —Standard Requirements for Metal Roofing Systems Standards Equivalency: The UL 580-94 & UL 1897-98 standard version used to test the evaluated product assembly is equivalent with the prescribed standards in UL 580-06 & UL 1897-04 adopted by the Florida Building Code 2010. Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 2010, Section 1504.3.2. Evaluation Report This product evaluation is limited to compliance with the structural requirements Scope: of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 9N-3.001. Limitations and . Scope of "Limitations and Conditions of Use" for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 9N-3.005. Per Rule 9N-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval'. • Option for application outside "Limitations and Conditions of Use" Rule 9N-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 9N-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) • This metal roof system was tested to transmit the roof loads directly to the building structural support deck. Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 9N-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA 1824). CBUCK Engineering FL #: FL 12966.6-113 Date: 4/6/12 Report No.: 12-132-5V-S6W-ER Page 4 of 9 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Components/Materials Roof Panel: "JM 5V Crimp" (by Manufacturer): Material: Steel Thickness: 26 gauge (min.) Panel Width: 24" (max.) Coverage Rib Height: 3/8" Yield Strength: 40 ksi min. Corrosion Resistance: In compliance with FBC Section 1507.4.3: • ASTM A792 coated, or • ASTM A653 G90 galvanized steel Fastener: Type: Hex -Head Wood Screw with WSW Size : #9 -15 x 1" Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.4 Adhesive/Seam Sealant: Product Name: Bostik Chem -Calk 915 Type: One component, polyurethane adhesive Application Size: 3/16" bead Application Location: along male flange the full length of panel underlaps (Refer to Table "A" and drawings Page 8) Components/Materials Underlayment: (by Others): Per roofing manufacturer's guidelines in compliance with FBC Section 1507.4.5 Insulation (Optional): Type: Thickness: Properties: Density: Or Compressive Strength Rigid Insulation Board 3" (max.) 2.25 pcf (Ibs/ft3) min. 20 psi min. Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". CBUCK Engineering FL #: FL 12966.6-113 Date: 4/6/12 Report No.: 12-132-5V-56W-ER Page 5 of 9 Speclalty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation: Installation Method: (Refer to drawings on Pages 6-7 of this report.) ■ Fastener spacing: Refer to Table "A" Below (along the length of the panel) ■ Row Spacing: Refer to Table "A" Below (along the row, across the panel profile) ■ Rib Interlock: Lapped ■ Minimum fastener penetration thru bottom of support, 3/16". ■ For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A" METHOD 1: METHOD 2: METHOD 3: Design Pressure: - 85 PSF -114.25 PSF -114.25 PSF Fastener Spacing: 12" 12" 12" Row Spacing: 12" 12" 12" Fastener Location: Corrugation Peaks Corrugation Peaks Corrugation Valleys Adhesive: Not required Refer to Drawing Details 2A & 2B Not required Install the "JM 5V Crimp" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 2010. The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: I. TAS 125-03 Uplift Test By Hurricane Test Laboratory, LLC (FBC Organization #TST ID: 1527) Method 1: Report 0223-0307-01; Test Date: 03 / 05 / 01- 03 / 08 / 01 Method 2: Report 0223-0913-07; Report Date: 09 / 08 / 08 Method 3: Report 0223-0517-06; Test Date: 05 / 19 / 06 - 05 / 22 / 06 2. Quality Assurance By Keystone Certifications, Inc. (QUA ID: 1824) JM Metals, Licensee #: 344 3. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) FL #: FL 12966.E-R3 Date: 4/6/12 CBUCK Engineering Page Report No.:121f39-5V-S6W-ER Speclalty Structural Encjlneerinc;j CBUCK, Inc. Certificate of Authorization #8064 Installation Method JM Metals "JM 5V Crimp" (26 Gauge) Roof Panel Attached to Wood Deck Profile Drawines 2N' Maximum Net Coverage "JM 5V Crimp" Panel Typical Panel Profile View TABLE "A" METHOD 1: METHOD 2: METHOD 3: Design Pressure: - 85 PSF -114.25 PSF - 114.25 PSF Fastener Spacing: 12" 12" 12" Row Spacing: 12" 12" 12" Fastener Location: Corrugation Peaks Corrugation Peaks Corrugation Valleys Adhesive: Not required Refer to Drawing Details 2A & 2B Not required FL #: FL 12966.6-113 Date: 4/6/12 CBUCK Engineering Page Report 12-132- -1 R 9 5V-SM-Ell Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation Method JM Metals "JM 5V Crimp" (26 Gauge) Roof Panel Attached to Wood Deck 12" o.c: Typical Fastener Spacing Across Panel 1Mdth ##9-15 Hex -Head Screw with Weather Seal washer 3116' min. penetration thru deck .Spaced 12" o.c. across the Panel Detail 1A - Typical Assembly Profile View (METHOD 1) Factanarc - -15/32" or greater Plywood, or rack l - Wood plank Thickneessss 33" Maximum Detail 1B - Typical Assembly Isometric View (METHOD 1) FL #: FL 12966.6-R3 Date: 4/6/12 CBUCK Engineering Page rt No.: 8 -1 9-5v-56w-ER Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation Method JM Metals "JM 5V Crimp" (26 Gauge) Roof Panel Attached to Wood Deck 12" o.c: Typical 3/16' Bead Bostick Adhesive along full length of male flange at panel undedaps Fastener Spacing Across Panel Width #9-15 Hex -Head Screw with Weather Seal washer 3/16" min. penetration thru deck .Spaced 12" o.c. across the Panel Detail 2A - Typical Assembly Profile View (METHOD 2) Fasteners - #9 -15 Hex -Head Screws With "JM 5\1 Crimp" Roof Panel EPDM Bonded Steel Washers Deck- - 15/3Z' or greater Plywood, or - Wood plank Optional: 3116' head Bostick adhesive J Rigid Insulation along panel underlaps Thickness 3" Maximum Detail 26 - Typical Assembly Isometric View (METHOD 2) FL #: FL 12966.6-113 Date: 4/6/12 Report N 2 CBUCK Engineerinq Page No.: 9 1f39-5V-S6W-ER Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation Method JM Metals "JM 5V Crimp" (26 Gauge) Roof Panel Attached to Wood Deck 12" o.c: Typical Fastener Spacinq Across Panel 1Mdth #19.15 Hex -Head Screw with Weather Seal washer &16" min. penetration thru deck Spaced 12" o.c. across the Panel Detail 3A - Typical Assembly Profile View (METHOD 3) FactPnarc - -1522" or greater Plywood, or Rigid Insulation - Wood plank Thickness 3" Maximum Detail 313 - Typical Assembly Isometric View (METHOD 3)