Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSJ DATE: / / I ' I I /` FtEES DUE: I X I I RECEIPT #: /'LJf /(nkJ)Permit #: I —T ( ')`r - U 1. Location/Site Address: Planning & Development Services Department Building & Code Regulation Division SCANNS® 2300 Virginia Avenue By Ft! Pierce, FL 34982-5652 St. Luc.I Tel.772-462-1553 @ Count APPLICATION FORROOF PERMIT SEE REVERSE SIDE FOR INSTRUCTIONS 230 Woodcrest Dr., Fort Pierce FL 34945-2036 2. Parcel ID Number- 2308-501-0018-000-8 3. 4. 6. 7. Office Use Section Tov+*nshi Ran' e , Ma Pa e a d Use Ini 'als. Only f 1 Description of Project or Work Activity: Reroof- Remove existing Roofing, DrvAn., and install new Asphalt Shingles. Total Roof Area (squ re feet):. 414S. Roof Pitch: 4 I I a Type of Roof: Fiber glass Shingle]Concrete Roof Tile [ J Rood Shake Shingle 1 [ ] Tar & Gravel [ ] Modified Bitumen j ] Other 1 [ ] Product Approval required for all types of Roofing Material (2 Sets) [ ] All Commercial Roofing requires design by an"Engineer or Architect (2 Sets) with Product Approval attached Rooff, Mitigation per F.S. 553.844 will be required. Owner Information 8. Contractor Information Name Thomas Powers Address: 230 Woodcrest Dr city: Ft Pierce State: FL Zip: 34945 Phone: 772-460-6109 9. Value of Construction: $ ],i , � `1 b FL Reg/Cert #: County Cert # CC-0057399 16414 Business Name: Trade Winds Roofing Inc. Cell Phone: 772-466-9420 **Note Dry -in, and Final Inspection Required. Additional inspection maybe required per Product Approval. CONTRACTORIOWNER'S AFFIDAVIT: I certify that all of 'the info ation contained in this application is correct and that all work will be done in compliance w a ap le l onstruction and zoning. Michael Miller PRINT QUALIFIERSIOWNERS NAME SIGNATURE OF QUALIEIEWOWNER C j i STATE OF FLORIDA, COUNTY OF :)A' 1 � I Q _ ACKNOWLEDGED BEFORE ME THISDAY OF20RY cha e I� 1 �� Felicia L nV AS IDENTIFICATION R' O IS PERSON LLY KNOWN TOME OR IIAS PRODUCEDi �i'+U11.�I� �aMI�E y Landee NOTARYKMW SIGNATURE OF O RY TYPE OR PRINT NAME OF NOTARY (seal) STATE �M� COMMISSION NUMBER C+MMN FMI20 NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26/2010 Sep 23 14 09:19a Trade Winds Roofing 772-466-9725 p.1 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit# 1409-0255 I, Michael Miller licensed as a(n)Contractor*/Engineer/Architect (Please print name & circle license type) IFS468 Building Inspector 'General, Building, Residential or Roofing Contractor or any individual certified under468 F.S. to moke such an inspection. On or about 09/24/2014 1 did personally inspect the roof deck nailing (Date) work at: 230 Woodcrest Dr., Fort Pierce, FL 34945 (Job site address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S,) CC-CO57399 Signature and Seal W STATE OF FLORIDA COUNTY OF License # Sw rn to and subscribed before me this day. of S—' 1bQV 20_ by V- r %(A-'-' I Ih�� l/ Who is ersonall kno toteme o"r who has produced as identification. Notary Public, State of FI id Signature - - FELQf: LYM GA4DEE Signatt ure of Notary: , C1 NOT�.RYPU 3J 0 Commission Number: (Seal STATE of FLORIDA En 01119/2011 CaNnO FTQ6I203 E)pMes 914=17 RECEIVED SEP-2 4 .2014 3 _ NOTICE OF COMMENCEMENT Permit No. Tax folio No. 2308-50 1!0018-000-8 State of Florida County -of St. Lucie The undersigned herebygives;notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement Legal Description of -Property: (and street address if available): 230 Woodcrest Dr., Fort Pierce FL 34945-2036 ORANGE PARK SID BL`. K B LOT 5 (1.03 AC) (OR 735-0926) General description of improvement: reroof Owner information or Lessee information if the Lessee contracted -for the improvement: Name Thomas B Powers Address Interest in property:. Name and address offee simple titleholder (if different from Owner listed above) Contractor's Name: Trade, Winds Roofing Inc. Contractor Address: P.O. Box 13208, Fort Pie Phone Number: Surety (if applicable, a copy of the payment bond is attached)::/lmount of bond: $ Name and address: ' Phone number: Lender Name: Phone Number: Lender's address: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as.provided by Section, 713.13(1) (a)7., Florida Statutes: Name: Address: Phone Number: In addition to himself or herself, Owner designates of to receive a copy of thl Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner: Expiration date of notice of commencement: (the expiration date may not be befor.,ethe completion of construction and final payment to tl contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BYTHE OWNER AFTERTHE EXPIRATION OFTHE NOTICE OF COMMENCEMENTARE CONSIDER IMPROPER PAYMENTS UNDER CHAPTER 713, PART[, SECTION 71113, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE. FII INSPECTION. IF YOU INTEND TO OBTAIN FINANCING; CONSULT WITH YOUR LENDERjOR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, I declare that l have read the foregoing notice of commencement and that the facts stated therein are true to.the best of my knoWledge and belief. �. 7S 0 X rn c-, Li �t 0 C ;o il (Signature of Owner or lessee, or 0 nei's or Lessees Authorized Officer/Director/Partner/Manager (Signatory's Title/Office) e The foregoing instrument was acknowledged before me this day ofp� •. , 20 q By as for 1(i(�rlr Name of Person Type of authority (e.g. officer, trustee) Party on behalf of whom instrument -was executed Personally known`orproduced Identification V (Signat re of Notary Pu lic-State of Florida 92Z�CNbD (Print, Type, orStamp C missioned Name of Notary Public) Type of identification produced I E IWMRLY A. HOPPLE 'sign in both places in front of a notary IAY CQMMI961ON # EE 833212EXPIRES; April 28, 2615 ` Bonded Thm Notary Public Underwriters Florida Building Code Online Page 1 of 2 a BCIS Home t Log In ,F User Registration Hot Topic ! Submit Surcharge Stats & Facts Publications i FBC Staff BCIS Site Map Links ;. Search Businessl;�) Professional ;'i �IUSER:PuCic�UerOVal Rpoulat car+ �t6y..A Product Aoproyai Menu > Product or Aooliwtion Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL10674-R9 Revision 2010 Approved N Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Greg Keeler greg.keeler@owenscorning.com Mel Sancrant 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Roofing Asphalt Shingles Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert J.M. Nieminen PE-59166 UL LLC 07/17/2017 John W. Knezevich, PE Validation Checklist - Hardcopy Received FL16674 R9 COI 2014 01 COI Nieminen.pdf Standard Year ASTM D3161, Class F 2006 ASTM D3462 2007 ASTM D7158, Class H 2O07 httn://www.floridabuildina.org/t)r/pr app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2... 9/17/2014 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 02/28/2014 03/05/2014 03/05/2014 04/18/2014 FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge Shingles and Starters shingles Limits of Use,.,, Installation Instructions Approved for'use in HVHZ: No FL10674 R9 II 2014 03 FINAL OC Asphalt Approved, for use outside HVHZ: Yes Shingles FL10674-R9.pdf Impact Resistant: N/A Verified By: Robert 3. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10674 R9 AE 2014 03 FINAL OC AsDhalt Shingles FL10674-R9.Ddf Created by Independent Third Party: Yes bad: Next Contact Us :: 1940 North Monroe Street Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EE0 employer. Copyright 2007-2013 State of Florida.:: Privacy Statement:: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electrontc mail to this entity. Instead, contact the office by phone orby traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(i), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455, F.S., please dick here . Product ,,Approval Accepts ICr�edttE httD://www.floridabuilding.org/pr/pr app_dtl.aspx?pararn=wGEVXQwtDgtBNbEY5V%2... 9/17/2014 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 TRNI ERD OXFORD, CT 06478 PHONE: (203) 26279245 FAX: (203) 262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R4 One Owens Corning Parkway FL110674`I19 Toledo, OH 43659 Date of Issuance: 02/06/2012 Revision 4: 03/04/2014 SCOPE: ' This Evaluation .Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance.with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: - y _ Robert 3.M9. Nieminen P.E.-';:' Florida Registration No. 59166, Florida DCA ANE1983 "'"""""" The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 03/04/2014 This does not serve as an electronically,signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity IERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: .Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards.. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pronerty Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 . Wind Resistance ASTM D3161•, Class F. 2006, 1507.2.7.1, R905.2.6.1 ,- Wind Resistance ASTM D7158, Class H 2O07 3. . REFERENCES: Entity Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol: 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2066 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance ' 4786093137 02/01/2014. UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs 'Various UL LLC (QUA9625) Quality Control Service Confirmation R2453 Exp. 09/26/2014 4. PRODUCT DESCRIPTIONa 4.1 Asphalt Shingles: r 1 , 4.1.1 Classic® and Supreme® are fiberglass reinforced,; 3-tab, asphalt roof shingles. 4.1.2 Berkshire® are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 DevonshireT" are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration®, TruDefinition° Duration, Duration° Premium Cool, TruDefnitionO Duration° Designer Color Collection, TruDefinition® OakridgeO, OakridgeO and WeatherGuard® HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip &•Ridge with Sealant, WeatherGuard° HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuralkidgeT'" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. Si. LIMITATIONS: 5.1 This Evaluation Report is not for use. in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization #9503 FL10674-1119 Revision 4: 03/04/2014 Page 2of7 ERD 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,,,t = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayrnent: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire° shingles require minimum five (5) nails per shingle. ➢ WeatherGuard° HP shingles require minimum six (6) nails per shingle. ➢ 'Devonshire TM shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization #9503 FL10674-R9 Revision 4: 03/04/2014 Rage 3 of 7 6.2.5 Minimum Nailing —Classic® & Supreme: Nonn I Mansard or Area pare' Wind Areas High Wind dosvpnes y Area porn vientos normales Areas vientos fuartes 1" IAl 1" 1 2'1 jsl r2' 1. . 1 5" Exposure Exposition 6.2.6 , Minimum Nailing -Berkshire®: Sealant strip La fife do segador O F— : + D �-9 0 4----> A VY, 9 Vi' 9 Yt' $ VP 1" 1" 6.2.7 Minimum Nailing - DevonshireTm: s HERD Normal Mansard or Arse pare Wind Areas High Wind desvanes y Area pores vientos nonnales Areas vientos fuerr®s �z r (A) 1z 1 1�Z 1- z� iB! i 2' V i 5 5/8"Exposure Exposition Sealant strip !a lira do s08ador 04--=0 0 a > o m t e e �1.8le 8Yt 8Vt' 8'il 1" tt 8 2" Asphalt rooting cement Cemento de techode astaffo Nails J, Ten 1" Spots of Asphalt Roof Cement 6.2.8 Minimum Nailing - Duration®, , TruDefinition® Duration, Duration® Premium Cool & TruDefinition® Duration® Designer Color Collection: 4 Nail Pattern Esquema de 4 davos SumNaPfastening area width Area de dam SureflailD —ty 1• 1' • tz• 6§'47 Exposure Nails 5Va Exposure 9.6 puig. de exposition Ctavos Ssfa pdtg. de exposition 6 Nail MarcardandSttip Slop? Lsttn txtmm surenato Pattern atfaandtep ct wtout. Esquema — c a: etros zasfr daaaae i des Sdavas ro aaScttb2�Yb�fs o � � lt�a4Gr drlrSt?i& SWttL=Y'' ♦ Smdlait, tiSnfdtryQ � k�ilfnu9pgt1 atf3nidtil 2na i9iYtt1 limda � T' . ♦ Rteada taros Surcmaa� L e— mv Expe ure Nails 5!VV Exposure w ptdg. do exposfeidn Vows w pulg. de exposition ' Exterior Research and Design, LLC. Evaluation Report 037940.02.12-114 Certificate of Authorization #9503 FL10674-Rg Revision 4: 03/04/2014 Page 4 of 7 6.2.9 Minimum Nailing - TruDefinition° Oakridge®, Oakridge@: 4 all Pattern Esquema con G clavos I� rr --al 14— 5518"Exposure Mails 55/8"Exposum ficposicd6ade5518puly. clavos Ezp051e:6ude6519pai5. 6.2.10 Minimum Nailing - WeatherGuard® HP: 4 a TRINITY D 6 Nail F.tttern Esquema con 6 clavas �- r Imo— z Ir Nail., 5 We, Exposme 55f8" Expasuv3 clavos Exposiron de 55/6pu(a Fay0stci6n de 5518p:rlg Sin pb Side Wow 1)i8s� femora► man 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard° HP Hip and Ridge Shingles and Pro Edge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidge-rm Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4 Certificate ofAuthoriaation #9503 FL10674-119 Revision 4: 03/04/2014 Page 5 of 7 6.3.3 6.3.4 Minimum Nailing — Berkshire® Hip & Ridge and High.Ridge: Fig. 1 q Prevailin9NAnd f%1 \ ptreuton�l'�� ° Hails 4 , 1 I 1 I j I 1 I I \A v v v w Exposure f I i F Sao' Fig. 2 TopVievt sideViety ff57s I�Tlatfs TOP LarNnated 2 • 1 T. Piece a f I I ti" I al .I UI v� I 1 1 1 Minimum Nailing — Hip & Ridge with Sealant: its F�j. 2 - High Wind inn Patten] US) Mal Shan---r Excmss lit I. Sealant StRI P i Distance 12 �. 6.3.5 Minimum Nailing — WeatherGuard® HP .Hip, and Ridge: Fig. A `q T, PrevallingYllntl ��'� �"^ Dlrectlon � Halls y q ` A 1 A i •� I I I I Ab i i I I I j 1 T Exterior Research and Design, LLC. Certificate of Authorization #9503 Fig. C Hip Ridge Shingle Fastening - TopVtevr Halls ttaft 2" 2" D t„ 1" g• orposurc I t� Evaluation. Report 037940.02.12-R4 FL10674-R9 Revision 4: 03/04/2014 Page 6 of 7 6.3.6 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Wind Direction Sealant Strip 6' Exposure � Fasten 719=° Cover Expa.%d Fasteners with Roof Cement Standard 17 Fastening Patter �— s 1j2' p Sealant 6' Exposure 6.3.7 Minimum Nailing - DuraRidgeT"' Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. F1,41 i,te41M,DitWipm. �'— Dsra�aanirz �sr,.a+yr�t 1) a_.:ondo!uuiY•apen:WTz " .s Top vw v Vez ea pL•.k Visia xuaartor !".s.� e —q ---- _ Q::':3i3 r`.Clt4tt 3 .'�a1:rz3! .!'• o � . ! Er O is W!o � t y i tt 71. LABEUNG: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1._ 8. BUILDIP3 9 PERNIET Rl:QUIEREMENTSo As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. N9iNwAcrumibe PLANTS." Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALYTY ASSURANCE lEmTfTvo UL LLC- QUA9625 ; (414) 248-6409; I<aren.buchr!ann c! ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R,4 eertiticate ofAuthorization #9503 FL10674-R9 Revision 4: 03/04/2014 Page 7of7