HomeMy WebLinkAboutSUBMITTED PAPERSDUE:
1 ri,
0
Permit
Planning &
APPLICA
;ldpment Services Department
,ACode Regulation Division
SC,q vtv
4 Virginia Avenue
fierce, FL 34982-5652
B
��, �UC�G
tel. 772-462-1553
L'OUnty
ON FOR ROOF PERMIT
1. Location/Site Address: 8160 Buckthorn Cir, Port St Lucie FL 34952
2. ParcelIDNumbe, 3425-701-0124-000-1
Office: Use
Only
Section
I Township
Ran ` e . ,
I Ma Pa a
I Zoning
I Land Use
Initials
-- 1
3. Description of Project or Work- Activity: r YC •
4. Total Roof Area (.square feet): i3 �� 5. Roof Pitch: 0 ' a
6. Type of Roof: 7Iberglass Shingle [ ] Concrete Roof Tile. [ ] Wood Shake 1,Shingle
] Tar & Gravel [ ] Modified Bitumen [ ] Other
[ ]Product Approval required for all types of Roofing. Material (2 Sets)
[ ] All Commercial Roofing requires design by An:Engineer or Architect. (2 .Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information S. Contractor Information,
Name: Marie Roudebush FL Reg/Cert.#: CC-CO57399
Address:. 8160 Buckthorn Cir County Cert.# 16414
Port St Lucie FL Trade Winds Roofing Inc.
City: State: Business Name: g
Zip: 34952 Phone.: Cell Phone: 772-340-3784 772-466-9420
9. Value of Construction: $ 6750
Note Dry -in and Final Inspection Required. Additional inspection maybe required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of �h mformation contained in this application is correct and that allwork will be
done in complian th all ap a laws re a ' g construction and zoning.
Michael Miller
PRINT QUALIFIERS/OWNERS NAME pp fIGNAHRE OF QUALIFIERIOWNER
STATE OF FLORIDA, COUNTY OF Z:)k ' "ke- 11.
ACKNOWLEDGED BEFORE ME THIS (� DAY OF N C1 r Ch 20_g Bk W i c hQ e y
WHO IS PERSONALITY KNOWN VITO ME;OR HAS PRODUCED! AS IDENTIFICATION
FE" Lym GANDEE
�AA ,QA,t a_a -nAAwau \� c � a< �?s1 v,ci�a�► � �lo AFW Pueuc
SIGNATURE OF NOTXRNU TYPE OR PRINT NAME OF NOTARY (seal) STATE OF FLOMDA
COMMISSION NUMBER I Caw# FMI20
4)EVbVs 9/4MIT
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COM1WENCEMENT MAY RESULT IN YOUR PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU:INTEND TO OBTAIN FINANCING; CONSULT YOUR LENDER OR
ATTORNEY" BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4/26120I0
i
Permit No.
State of Florida County of St. Lucie
NOTICE OF COMMENCEMENT
Tax folio No. 3425-701=0124-000-1.
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,
the following information'is provided in this Notice of Commencement.
Legal Description of Property: (and street
BLK 5 LOT11
General description of improvement: reroof
Owner information or Lessee information if the Lessee contracted -for the improvement:.
Name Glen E Roudebush & Marie L Roudebush
Address 8160 Buckthorn Cir., Port St Lucie FL 34952
Interest in property:
Name and address of fee simple titleholder (if different from Owner listed above):
Contractor's Name: Trade Winds Roofing Inc.
Contractor Address: P•O: Sox 13208, Fort Pierce FL 3 979 Phone Number. 772-4 6-94.20
Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $
Name and address: ' Phone number:
Lender Name: Phone Number:
Lender's address:
I
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Secti
713.134) (a)7., Florida Statutes:
Name: Phone Number:
Address:
In addition to himself orherself, Owner designates of to receive a copy of
Lienoes Notice as provided in Section 713.13(1) (b), Florida'Statutes.
Phone number of person or entity designated by owner.
Expiration date of notice of commencement; (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 year from the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER .AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER'PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 71113, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TINICE,FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE ]OB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER'OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
z0Tvn6.
0WM in
zm
A W -0
Z ,J ID C m
G3 of C) m
rnrn
�D0 O-4
o6)8a=
o„ <m
o >`
o r� O
00 F 17
m
m 0
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and thatthe facts stated therein are true to -the best of
mvJmowledee and belief/
(Signature of Owner or Lessee, or Owner's or Lessee's Authorized
The foregoing instrument was acknowledged before me this 1J day of 1' a% ch , 201_q
FEUCIA LYNE GANDEE
NOTARY PUBLIC
STATE OF FLORIDA
. CM7V* FF051283
EXPIM 9/4/2017
By �AQL10, LULL 5'L as OUL�l11' ��l for �'jt,G l p C -i-h„� n Ck
Name of Person Type of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed
Personally known_ or produced Identification
(Signature of Notary O&Iic - State.of Florida)
(Print, Type, or Stamp Commissioned Name of Notary Public) Type of Identification produced -' L
3 ta-
**; sign in both places in front of a notary
Florida Building Code Online Page 1 of 2
M,�.k.x�r_{,�fit � 6 � `' � .� �'. .3.,r ^ `e 9 c : `i V � �, r� ,,,y$�� � l -N"w j ��^ k-� 4� wS`}r� S� n { ]� 4..a$. 1 �R3�3��.`i x iS'Y i'.{ h%.�„L^1 f D k 3 ._.,.>v_.�...:tu„�...'......,s..,-.G...;x.._.._.<,..-.€Nc.:�....��,.,."�._..,......c,....r.;�
Jryijj aLaer-;,aryit�` BCIS Home ; Log In ' User Registration Hot Topics Submit SurchargF&fpcts &6bllications FBC Staff BCIS Site Map Unks Search
Business/ t =
Profess&al V }Product Approval
USER: Public User Lk COPY
Regulation
Product AODroyal Menu > Product or Aoolication Search > Aonlication List, > Application Detail
FL #
FL10674-116
Application Type
Revision
Code Version
2010
Application Status
Pending FBC Approval
Comments
Archived
Product Manufacturer Owens Coming
Address/Phone/Email One Owens Coming Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
greq.keeler@owenscoming.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscomig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who Robert J.M. Nieminen
developed the Evaluation Report
Florida License PE-59166
Quality Assurance Entity Underwriters Laboratories Inc.
Quality Assurance Contract Expiration Date 09/26/2014
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL10674 R6 COI Trinity ERD CI - Nieminen.odf
Referenced Standard and Year (of Standard) Standard Year
ASTM D3161, Gass F 2006
ASTM D3462 2007
ASTM D7158, Class H 2O07
Equivalence of Product Standards
Certified By
h"://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V %2... 3/29/2012
Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/16/2012
Date Validated 02/21/2012
Date Pending FBC Approval 02/24/2012
Page 2 of 2
FL JIMlodel,
Number or Name
IDescription
10674.1
Owens Coming Asphalt Roofing
3-tabr laminated, starter, and hip & ridge
Shingles and Starters
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER, Section 5.
Installation Instructions
FL10674 R6 II er020612FINAL OC FL10674-
R6 Asphalt Shinoles.pdf
Verified By: Robert J. M. Nieminen PE - 59166
Created by Independent Third Party: Yes
Evaluation Reports
FL10674 R6 AE er020612FINAL OC FL10674-
R6 Asphalt Shinoles.odf
Created by Independent Third Party: Yes
Sadc Nezi
Contact Us,.,. 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovriaht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions regarding DBPR's ADA web
accessibility, please contact our Web Master at webmaster@dbpr.state.fl.us.
Product Approval Accepts:
EE�ECt
�cvrit�-�i r i :r• x
vari5ign �
rry Fed r
httD://www.floridabuUdin,.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2... 3/29/2012
Certificate of Authorization #9503
August 01, 2011
RE: Certification of Independence, Florida F.A.C. Rule 9N-3
To Whom It May Concern:
This letter serves to document the following in accordance with Florida F.A.C. Rule 9N-3:
I . Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or
will it acquire, a financial interest in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any
company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company
manufacturing or distributing products for which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved
in the approval process of the product.
Please contact our office with any questions.
Sincerely,
Robert Nieminen, P.E.
Florida Reg. No. 59166
Vice President
Email: robertnieminen@trinityerd.com
EXTERIOR RESEARCH Ii; DESIGN, LLC. d/b/a TrinitylERD —Certificate of Authorization #9503
MAIN: 80 Yesler Way . Suite 200 . Seattle, WA 98104 . P: (206) 467-0054 . F: (206) 467-5840
EAST: 353 Christian Street Unit 13 . Oxford, CT 06478 . P: (203) 262-9245 . F: (203) 262-9243
FVOL"ATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report 037940.Uz.iz
FL10674-R6
Date of Issuance: 02/06/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify, Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityIERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
0
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P.E. on 02/06/2012
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity IERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of'the Florida Building Code and Florida Building
Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard
Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462
2007
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F
2006
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H
2O07
3. REFERENCES:
Entity Examination Reference
Date
UL (CER1739) Physicals & Wind Resistance File R2453, Vol. 3
02/15/2007
UL (TST1740) Physical Properties 06CA20263
04/18/2006
Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12
02/14/2008
Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12
12/16/2009
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07
10/27/2010
Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03
06/16/2011
Miami -Dade (CER1592) FBC HVHZ Compliance 11-0919.05
10/13/2011
UL (QUA1743) Quality Control Service Confirmation
Exp. 09/26/2014
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic° and Supreme@ are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 Duration°, Duration° Premium, Oakridge® and WeatherGuardO HP are fiberglass reinforced,
laminated asphalt roof shingles.
4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuarde HP
Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating
the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„it = 194 mph).
Refer to Section 6 for installation requirements to meet this wind rating.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12
Certificate of Authorization *9503 FL10674-RG
Date of Issuance: 02/06/2012
Page 2 of 6
I
TRINITY- ER®
5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in
accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all wind zones up to V,,d = 150 mph (Vi,(t = 194 mph). Refer
to Section 6 for installation requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4
or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
or R905.2, with the following exceptions:
➢ Berkshire® shingles require minimum five (5) nails per shingle.
➢ WeatherGuard`9 HP shingles require minimum six (6) nails per shingle.
➢ Starter Strip Plus requires minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing — Classic@ & Supreme:
Normal Mansard or Area pars
Wind Areas High Wind dosvenos y
Area pars vionros normaios Areas vionros fuerres
rt' (AI
5'Exposure
Exposition
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Normal Mansard or Area pare
Wind Areas High Wind desvunes y
Area pare vienros normaias Areas vientos fuertos
ttz t �lAl\ rz t t (BI I r
6 5/8' Exposure
Exposition
Evaluation Report 037940.02.12
FL10674-R6
Date of Issuance: 02/06/2012
Page 3of6
6.2.6 Minimum Nailing — Berkshire®:
Sealant strip
La 1ha de sedadar
o e -t
A ti' 9 Yt' 9 SPC 1 A Yt'
Sealantslap
!a grade Sander
La w
ey
Sw a yr t. J
e
Zr"
Asphalt roofing cement
Cameato de techo de Malta
6.2.7 Minimum Nailing — Duration® & Duration® Premium:
4 Waft Pattern
Esquema de 4 davos
SuwNagattstening area width
Area de dowsSureNaiP
r r
n• tY
5 n" Exposure Nags Exposure
6b purg. de exposicvn Claws 6%puig. de exposfcrdn
6.2.8 Minimum Nailing — Oakridge®:
4 Nail Pattem
aquema Cott 4 Claws
t• t•
14— >z• •--IDI Imo— ,Y —�I
�L�a V---�
5 5f8" Exposure Malls 5 5/8" Exposure
Fxposiddn de 6 USpidg Cray, Expos1d6nde69/2puig.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
6 Nag #lin klcpithu0�ado
Pattern wanatce m cut ova.
Esquema — Iiars;rUa al,�iE.Nes
deSdavos t afio'Zipp, a7
O xpoor tl ramb.m!a
'1 rraaiu rklraa7a
sunuaT \ Sdran'
auaw'die
fnilK � Uslmin9
'arretsicin
A-Ua t" � \1 F�in0
Soria �' �— 1T —� ` �E— 77' ' Sm to uifa
5T Exposure Nails 5Ye' Exposure
5t5 pufg. do o(posirrdn Clawn SSi purg. do mposidaa
6 Nail Pattern
Esquema colt S Caws
t` t"
NaiLq
5 5f8" Exposure Craves 5 518" P P$=
Evposfddn de 66/8poig. Exposwa de 66/6 purr.
Evaluation Report 037940.02.12
FL10674-R6
Date of Issuance: 02/06/2012
Page 4 of 6
6.2.9 Minimum Nailing — WeatherGuardp HP:
81o& era. VkW
ilCrri L�6srai
dw��oiallr6l�rJir
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant and
WeatherGuardO HP Hip and Ridge Shingles shall comply with the manufacturer's current
published instructions, using four (4) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2
6.3.3
6.3.4
Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:
Minimum Nailing — Hip & Ridge with Sealant:
item Fig. 2 - High Wind Fasmkg Paftegn
K Naols)
Trig" Shingle
(1=xt-, �..Lr
Sealant21
Strip a a 112"
' Fastening 6'Y, 5 Exposure
12 v
Fig. 2
Tallifim SWUM
�i Nail'ss Nails
Z I T pLaninated PiI Z {
ece
' t' 0
I
I
m�
�I
—I
UI
I
I
I
I
Exterior Research and Design, LLC. Evaluation Report 037940.02.12
Certificate of Authorization #9503 FL10674-116
Date of Issuance: 02/06/2012
Page 5 of 6
6.3.5 Minimum Nailing - WeatherGuard® HP Hip and Ridge:
Fig. A 4 4
Prevalling Wintl
A
11011r. 4 0
I I
A\ p I I
I I
I I
I I
A I I I I
I I I I
Exposure
7. LABELING:
Fig. C Hip & Ridge Shingle Fastening
Top Merl
T'
2" 2"
�. 1.
Exposure
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
Underwriters Laboratories - QUA1743; (414) 248-6409; karen.buchmannaui.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 037940.02.12
Certificate of Authorization #9503 FL10674-116
Date of Issuance: 02/06/2012
Page 6 of 6
Florida Building Code Online r_, Page 1 of 2
t r 4
SCIS Home i Log In ! User Registration , HotTopics i Submit Surcharge i
Business ,7 ProdProfessional ffixUSER:PubicUser al
20
Sets & Facts Publications j FBC Staff i BCIS Site Map links 'Search `.
Product Approval Menu > Product or Application Search > Application List > Application Detail
�t uazT % FL # FL2569-R6
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Revision
2010
Approved'
soprema, Inc. (Canada)
1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400 Ext3327
memathieu@soprema. ca
Marc -Etienne Mathieu
memathieu@soprema. ca
Marc -Etienne Mathieu
1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819) 478-2400 Ext3327
memathieu@soprema.ca
Jean -Francois Cote, Ph.D.
1640 rue Haggarty
Drummondville
(888) 811-3145
jfcote@soprema.ca
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a
Licensed Florida Professional Engineer
V, Evaluation Report -Hardcopy Received
Robert J. M. Nieminen
PE-59166
UL LLC
11/30/2014
John W. Knezevich, PE
Validation Checklist -Hardcopy Received
FL7569 R6 COI Trinity EP.D CI -Nieminen - 2013.odf
Standard
Year
ASTM D1623
2009
ASTM D1970
2001
ASTM D6163
2000
ASTM D6164
2005
FM 4474
2004
FRSA/TRI07320
2005
TAS 103
1995
TAS 110
2000
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 10... 12/6/2013
Florida Building Code Online
Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 05/22/2013
Date Validated 06/12/2013
Date Pending FBC Approval 06/12/2013
Date Approved 08/23/2013
Summr_ ary of Products
FL #
Model, Number or Name
Description
2569.1
Soprema Roof
Self adhering roof underlayments
Underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2569 R6 II er052213FINAL SOPREMA CA UNDERLAYMENTS FL2569-
R6. Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen, P.E. PE-59166
Design Pressure: +N/A/-90
Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for Limits of
Evaluation Reports
Use. 2.) The design pressure noted herein
FL2569 R6 AE erO52213FINAL SOPREMA CA UNDERLAYMENTS FL2569-
R6.DdF
pertains to underlayment systems used
beneath adhesive -set tile systems. Refer to
Created by Independent Third Party: Yes
ER Section 5.5.4 for details.
Bade Wezt
Contact Us :: 1940 North Monroe Street Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under
Chapter 455, F.S., please dick here .
Product Approval Accepts:
Et-t
http://www.floridabuilding.org/car/car app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 10... 12/6/2013
r TRINITY! ERD
EVALUATION REPORT
Soprema, Inc.
1640 rue Haggerty
Drummondville, Qu6bec 32C 5P8
Canada
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report S18010.06.09-114
FL2569-RG
Date of Issuance: 06/15/2009
Revision 4: 05/22/2013
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert 3.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized
by Robert Nieminen, P.E. on 05/22/2013
This does not serve as an electronically signed
document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and
to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
A
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with
the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2004
1507.2.4, 1507.2.9.2,
Physical Properties
ASTM D1970
2001
1507.5.3
1507.11.2
Physical Properties
ASTM D6163
2000
1507.11.2
Physical Properties
ASTM D6164
2005
1523.6.5.2.1
Physical Properties
TAS 103
1995
1523.6.5.2.17.3
Tensile Adhesion
ASTM D1623
2009
TAS 110
Accelerated Weathering
TAS 110
2000
1507.3.3
Installation Practice
FRSA/TRI 07320
2005
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
ASTM D1970 / TAS 110
2968.05.04-2
05/14/2004
ERD (TST6049)
Physical Properties
2757.02.05
02/03/2005
ERD (TST6049)
ASTM D1970 / TAS 110
2974.03.05-2
05/17/2005
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
Wind Resistance
2779.11.05-R1
04/18/2007
ERD (TST6049)
TAS 103 / TAS 110
S7120.11.07-2
11/02/2007
ERD (TST6049)
ASTM D1970 / TAS 110
S13190.02.09-111
04/01/2010
ERD (TST6049)
ASTM D1970 / TAS 110
S31370.03.10-1-R1
04/07/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
S11150.05.10-R1
09/09/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
S11150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970
S37210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970
S40540.02.13-1
02/19/2013
M-D (CER1592)
HVHZ Compliance
09-1005.02
11/04/2010
M-D (CER1592)
HVHZ Compliance
11-1206.04
03/15/2012
ICC-ES (EVL2396)
2012, 2009 and 2006 IBC Compliance
ESR-1524
03/01/2013
UL, LLC (QUA9625)
Quality Control
Service Confirmation
Exp. 11/30/2014
4. PRODUCT DESCRIPTION:
4.1 LAsrOBOND TU is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen
roof underlayment.
4.2 LAsrOBOND SHIELD is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths; 36 and 45 inch.
4.3 LAST060ND SHIELD HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS
modified bitumen roof underlayment.
4.4 LASTOBOND PRo HT-N is a self -adhering, woven polyethylene surfaced, SBS modified bitumen
roof underlayment available in two widths; 36 and 45 inch.
4.5 LAsrOBOND PRo HT-S is a self -adhering, woven polyethylene surfaced, high temperature, SBS
modified bitumen roof underlayment.
Exterior Research and Design, LLC. Evaluation Report S18010.06.09-R4
certificate of Authorization #9503 F1_2569-116
Revision 4: 05/22/2013
Page 2 of 8
f �
II CITY�ERD
4.6 LASTOBOND 195 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen
roof underlayment.
4.7 LAsToBOND is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof
underlayment.
4.8 LAsToBOND Eco is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen
roof underlayment.
4.9 LAsToBOND SMOOTH SEAL HT is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified
bitumen roof underlayment.
4.10 REslsro EcoNo is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen
roof underlayment.
4.11 RESIsTo LB1236 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen
roof underlayment, with a 36-inch sheet width.
4.12 PRIMESOURCE GRIP -RITE EAVE & VALLEY PROTECTOR is a Self -adhering, glass -mat reinforced, sand -
surfaced, SBS modified bitumen roof underlayment, with a. 36-inch sheet width.
4.13 EcoSTAR, LLC. GLACIER GUARD 100 is a self -adhering, glass -mat reinforced, sand surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width.
4.14 REsisTo LB1244 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen
roof underlayment, with a 44-inch sheet width.
4.15 COLPHENE FR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified
bitumen roof underlayment.
4.16 UNILAY (E) is a mechanically attached, polyester reinforced, granule -surfaced, SBS modified
bitumen roof underlayment:
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.3 Soprema Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to
the AHJ for approval based on this evaluation combined with supporting data for the prepared
roof covering.
5.4 Allowable roof covers applied atop the underlayments are follows:
Table 1: Roof Cover Options
Underlayment
Asphalt
Nail -On
Foam -On
Metal
Wood Shakes
Slate
Shingles
Tile
Tile
& Shingles
Lastobond TU
Yes
Yes
No
No
Yes
Yes
Lastobond Shield / Pro HT-N
Yes
No
No
No
Yes
Yes
Lastobond Shield HT / Pro HT-S
Yes
No
No
Yes
Yes
Yes
Lastobond / Lastobond 195
Yes
No
No
No
Yes
Yes
Lastobond ECO / Resisto Econo /
Resisto LB1236, Grip -Rite Eave &
Yes
No
No
No
Yes
Yes
Valley Protector or Glacier Guard
100 / Resisto LB1244
Lastobond Smooth Seal HT
Yes
No
No
Yes
Yes
Yes
Colphene FR GR
Yes
Yes
See es5.
No
Yes
Yes
Unilay (e)
Yes
Yes
I Batten Only1.
Yes
See 5.4.1
No
No
No
Exterior Research and Design, LLC. Evaluation Report S18010.06.09-R4
certificate of authorization #9503 FL2569-R6
Revision 4: 05/22/2013
Page 3 of 8
ER.D
5.4.1 "Foam -On Tile" is limited to use of 3M 2-Component Foam Roof Tile Adhesive AH-160 unless
tensile adhesion / long term aging data from an accredited testing laboratory is provided.
5.5 Allowable substrates are noted below:
5.5.1 Direct -Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT or Lastobond Pro HT-S applied
to:
➢ Plywood;
➢ ASTM D41 primed plywood;
➢ OSB;
➢ ASTM D41 primed OSB;
➢ Southern Yellow Pine;
➢ ASTM D41 primed Southern Yellow Pine;
➢ ASTM D41 primed structural concrete.
Lastobond TU, Lastobond, Lastobond 195, Lastobond ECO, Resisto Econo, Resisto LB1236,
Grip -Rite Eave & Valley Protector, Glacier Guard 100, Resisto LB1244 or Lastobond Smooth
Seal HT applied to:
➢ Plywood;
➢ ASTM D41 primed plywood.
Colphene FR GR applied to:
➢ Plywood;
➢ ASTM D41 primed plywood;
➢ ASTM D41 primed structural concrete.
Note:
➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema
recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not
slated for installation within 24 hours.
➢ Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior
to installation of the self -adhering underlayment.
5.5.2 Bond -to -Insulation:
Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT, Lastobond Pro HT-S or Colphene
FR GR applied to:
➢ DensDeck DuraGuard;
➢ DensDeck Prime;
➢ SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be
attached per minimum requirements of the prepared roof covering manufacturer's Product
Approval. For installations under foam, on tile systems, insulation attachment shall be
designed by a qualified design professional and installed based on testing of the
insulation/underlayment system in accordance with FM 4474, Appendix D or TAS 114,
Appendix I
5.5.3 Bond to Mechanically Attached Base Layer:
Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT, Lastobond Pro HT-S or Colphene
FR GR applied to:
➢ ASTM 13226, Type I or II felt;
➢ Sopra-G;
➢ Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be
attached per minimum codified requirements. For installations under foam -on tile systems,
base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120.
Exterior Research and Design, LLC. Evaluation Report S18010.06.09-R4
Certificate ofAuthorization #9503 FL2569-RG
Revision 4: 05/22/2013
Page 4 of 8
4,
z
9 ERD
5.5.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320
does not address wind uplift resistance of all underlayment systems beneath foam -on tile
systems, where the underlayment forms part of the load -path. The following wind uplift
limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are
used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind
load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of
design wind pressures.
5.5.4.1 Maximum Design Pressure = -45.0 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) Elastocol Stick or Elastocol 600c
Underlayment: Colphene FR GR, self -adhered.
5.5.4.2 Maximum Design Pressure = -67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol600c
Underlayment: Colphene FR GR, self -adhered.
5.5.4.3 Maximum Design Pressure = -60.0 pst.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch
o.c. in three, equally spaced rows in the center of the sheet.
Underlayment: Colphene FR GR, self -adhered
5.5.4.4 Maximum_Desion Pressure = -90.0 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e) mechanically attached with Soprafix Polymer Batten Bar (PBB) or
Soprafix Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-
inch o.c, within the 5-inch wide, self -adhering side laps. End laps are 6-inch
wide and sealed using either heat -welding or hot-air welding techniques.
5.6 Exposure Limitations:
5.6.1 Lastobond TU, Lastobond Shield, Lastobond Pro HT-N, Lastobond, Lastobond 195,Lastobond
Eco, Lastobond Smooth Seal HT, Resisto Econo, Resisto LB1236, Grip -Rite Eave & Valley
Protector or Glacier Guard 100 or Resisto LB1244 shall not be left exposed for longer than 30-
days after installation.
5.6.2 Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days
after installation.
5.6.3 Colphene FR GR or Unilay(e) shall not be left exposed for longer than 180-days after
installation.
5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth
Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief
titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of
02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems.
Exterior Research and Design, LLC. Evaluation Report 518010.06.09-R4
Certificate of Authorization #9503 FL2569-116
Revision 4: 05/22/2013
Page 5of8
i
iTRINITYIRD
Table 2: He S stem Options per FRSA TRI 07320 8-05
System
Underlay
Option
Section
Reference
Product(s)
3.02A
1
Batten
Modified Cap Sheet
Unilay(e)
System One:
only
Mechanically Fastened
5
3.02E
Self -Adhered
Lastobond TU, Colphene FR GR
Tile, Unsealed or
Underlayment
Sealed Underlayment
Base Layer: ASTM D226, Type II;
System
No. 30 / Self -Adhered
Sopra-G; Modified Sopra-G
6
3.02F
Underlayment
Top Layer: Lastobond TU,Colphene FR
GR
4
3.02D
Self -Adhered
Lastobond TU, Colphene FR GR
System Two:
Underlayment
Mechanically Fastened
Base Layer: ASTM D226, Type IT;
Tile, Sealed
No. 30 / Self -Adhered
Sopra-G; Modified Sopra-G
Underlayment System
5
3.02E
Underlayment
Top Layer: Lastobond TU, Colphene FR
GR
1
3.02A
Modified Cap Sheet
Unila e
System Four "A":
4
3.02D
Self -Adhered
Colphene FR GR
Adhesive -Set Tile,
Underla ment
No. 30 / Self -Adhered
Base Layer: ASTM D226, Type II;
Unsealed or Sealed
Underlayment System
5
3.02E
Underlayment
Sopra-G; Modified Sopra-G
Top Layer: Colphene FR GR
System Four "B":
3
3.02C
Self -Adhered
Underlayment
Colphene FR GR
Adhesive -Set Tile,
Base Layer: ASTM Type II;
Sealed Underlayment
4
3.02D
No. 30 / Self -Adhered
Modified Sopra-pra-G
System
Underlayment
Tr: Colphene FR GR
Toopra Layer:
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published
installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the
substrate thoroughly to remove any dust and debris prior to application, and prime the
substrate with Elastocol Stick or Elastocol 600c (if applicable).
6.3 Lastobond TU Lastobond Shield Lastobond Pro HT-N Lastobond Shield HT, Lastobond Pro
HT-S Lastobond Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Resisto Econo,
Resisto 1_131236 Grip -Rite Eave & Valley Protector or Glacier Guard 100, Resisto LB1244 or
Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC
Sections 1507 for the type of prepared roof covering to be installed.
6.3.2 For non -tile aDDlications:
6.3.2.1 While priming is optional, Soprema recommends priming with Elastocol Stick or Elastocol
600c if the final roof cover is not slated for installation within 24 hours.
6.3.2.2 Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel
back the first 3 ft of release film.
6.3.2.3 Adhere the exposed part to the substrate and unroll the remaining membrane as far as
possible.
6.3.2.4 Once the entire length of membrane is in place, peel -off the release film diagonally while
holding the membrane tight. Firmly roll the membrane into place to achieve a bond.
Exterior Research and Design, LLC. Evaluation Report S18010.06.09-114
CertiFcate of Authorization #9503 FL2569-R6
Revision 4: 05/22/2013
Page 6 of 8
1
TRINITY( ERD
6.3.2.5 Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams
should be 6-inches and staggered not less than 2-ft from vertical seams in the course below.
All over -granule end -laps shall be sealed using either heat -welding or hot air welding
techniques.
6.3.2.6 When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area
at the top of the sheet at 12-inch o.c.
6.3.2.7 For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper
and center sheet over valley or ridge. Drape and press sheet into place, working from the
center of the valley or ridge in each direction. For valleys, apply the sheet starting at the
lowest point and work upward.
6.3.3 For tile applications:
6.3.3.1 Reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2
herein, using the instructions noted above as a guideline.
6.3.3.2 For Colphene FR GR in foam -on the applications, reference is made to Section 5.5.4 herein
for wind resistance limitations.
6.3.3.3 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
6.4 Unilay(e):
6.4.1 For non -tile applications or nail -on, battened tile applications:
6.4.1.1 Reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2
herein.
6.4.1.2 Apply sheet parallel to the roof edge and, starting at the eave with the selvedge -edge
upslope, mechanically attach the 5-inch wide selvedge -edge to the wood deck with nails and
tin caps or round cap -nails spaced 36-inch o.c. Apply the second course in a water -shedding
manner with self -adhering side -laps. Vigorous hand or motorized roller pressure is applied to
the self -adhering laps to ensure a watertight application.
6.4.1.3 Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in
the course below. All over -granule end -laps shall be sealed using either heat -welding or hot
air welding techniques.
6.4.1.4 Tile (if applicable) shall be loaded and staged in a manner that prevents the slippage and/or
damage to the underlayment.
6.4.2: For foam -on tile applications:
6.4.2.1 Reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2
herein.
6.4.2.2 Apply sheet parallel to the roof edge and, starting at the eave with the selvedge -edge
upslope, mechanically attach the 5-inch wide selvedge -edge to the wood deck Soprafix
Polymer Batten Bar (PBB) or Soprafix Metal Batten Bar (MBB) with Soprema #15-EL
fasteners spaced 6-inch o.c. Apply the second course in a water -shedding manner with self -
adhering side -laps. Vigorous hand or motorized roller pressure is applied to the self -
adhering laps to ensure a watertight application.
6.4.2.3 Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in
the course below. All over -granule end -laps shall be sealed using either heat -welding or hot
air welding techniques.
6.4.2.4 Tile (if applicable) shall be loaded and staged in a manner that prevents the slippage and/or
damage to the underlayment.
Exterior Research and Design, LLC. Evaluation Report S18010.06.09-R4
Certificate of Authorization #9503 FL2569-116
Revision 4: 05/22/2013
Page 7 of 8
LABELING:
Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 9N-3
QA requirements.
QUALITY ASSURANCE ENTITY:
UL, LLC - QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report S18010.06.09-114
Certificate of Authorization #9503 FL2569-RG
Revision 4: 05/22/2013
Page 8 of 8