HomeMy WebLinkAboutSUBMITTED PAPERSDUE: 1 ri, 0 Permit Planning & APPLICA ;ldpment Services Department ,ACode Regulation Division SC,q vtv 4 Virginia Avenue fierce, FL 34982-5652 B ��, �UC�G tel. 772-462-1553 L'OUnty ON FOR ROOF PERMIT 1. Location/Site Address: 8160 Buckthorn Cir, Port St Lucie FL 34952 2. ParcelIDNumbe, 3425-701-0124-000-1 Office: Use Only Section I Township Ran ` e . , I Ma Pa a I Zoning I Land Use Initials -- 1 3. Description of Project or Work- Activity: r YC • 4. Total Roof Area (.square feet): i3 �� 5. Roof Pitch: 0 ' a 6. Type of Roof: 7Iberglass Shingle [ ] Concrete Roof Tile. [ ] Wood Shake 1,Shingle ] Tar & Gravel [ ] Modified Bitumen [ ] Other [ ]Product Approval required for all types of Roofing. Material (2 Sets) [ ] All Commercial Roofing requires design by An:Engineer or Architect. (2 .Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. 7. Owner Information S. Contractor Information, Name: Marie Roudebush FL Reg/Cert.#: CC-CO57399 Address:. 8160 Buckthorn Cir County Cert.# 16414 Port St Lucie FL Trade Winds Roofing Inc. City: State: Business Name: g Zip: 34952 Phone.: Cell Phone: 772-340-3784 772-466-9420 9. Value of Construction: $ 6750 Note Dry -in and Final Inspection Required. Additional inspection maybe required per Product Approval. CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of �h mformation contained in this application is correct and that allwork will be done in complian th all ap a laws re a ' g construction and zoning. Michael Miller PRINT QUALIFIERS/OWNERS NAME pp fIGNAHRE OF QUALIFIERIOWNER STATE OF FLORIDA, COUNTY OF Z:)k ' "ke- 11. ACKNOWLEDGED BEFORE ME THIS (� DAY OF N C1 r Ch 20_g Bk W i c hQ e y WHO IS PERSONALITY KNOWN VITO ME;OR HAS PRODUCED! AS IDENTIFICATION FE" Lym GANDEE �AA ,QA,t a_a -nAAwau \� c � a< �?s1 v,ci�a�► � �lo AFW Pueuc SIGNATURE OF NOTXRNU TYPE OR PRINT NAME OF NOTARY (seal) STATE OF FLOMDA COMMISSION NUMBER I Caw# FMI20 4)EVbVs 9/4MIT NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COM1WENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU:INTEND TO OBTAIN FINANCING; CONSULT YOUR LENDER OR ATTORNEY" BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Revised 4/26120I0 i Permit No. State of Florida County of St. Lucie NOTICE OF COMMENCEMENT Tax folio No. 3425-701=0124-000-1. The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information'is provided in this Notice of Commencement. Legal Description of Property: (and street BLK 5 LOT11 General description of improvement: reroof Owner information or Lessee information if the Lessee contracted -for the improvement:. Name Glen E Roudebush & Marie L Roudebush Address 8160 Buckthorn Cir., Port St Lucie FL 34952 Interest in property: Name and address of fee simple titleholder (if different from Owner listed above): Contractor's Name: Trade Winds Roofing Inc. Contractor Address: P•O: Sox 13208, Fort Pierce FL 3 979 Phone Number. 772-4 6-94.20 Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ Name and address: ' Phone number: Lender Name: Phone Number: Lender's address: I Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Secti 713.134) (a)7., Florida Statutes: Name: Phone Number: Address: In addition to himself orherself, Owner designates of to receive a copy of Lienoes Notice as provided in Section 713.13(1) (b), Florida'Statutes. Phone number of person or entity designated by owner. Expiration date of notice of commencement; (the expiration date may not be before the completion of construction and final payment to the contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER .AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER'PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 71113, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TINICE,FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE ]OB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER'OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. z0Tvn6. 0WM in zm A W -0 Z ,J ID C m G3 of C) m rnrn �D0 O-4 o6)8a= o„ <m o >` o r� O 00 F 17 m m 0 Under penalty of perjury, I declare that I have read the foregoing notice of commencement and thatthe facts stated therein are true to -the best of mvJmowledee and belief/ (Signature of Owner or Lessee, or Owner's or Lessee's Authorized The foregoing instrument was acknowledged before me this 1J day of 1' a% ch , 201_q FEUCIA LYNE GANDEE NOTARY PUBLIC STATE OF FLORIDA . CM7V* FF051283 EXPIM 9/4/2017 By �AQL10, LULL 5'L as OUL�l11' ��l for �'jt,G l p C -i-h„� n Ck Name of Person Type of authority (e.g. officer, trustee) Party on behalf of whom instrument was executed Personally known_ or produced Identification (Signature of Notary O&Iic - State.of Florida) (Print, Type, or Stamp Commissioned Name of Notary Public) Type of Identification produced -' L 3 ta- **; sign in both places in front of a notary Florida Building Code Online Page 1 of 2 M,�.k.x�r_{,�fit � 6 � `' � .� �'. .3.,r ^ `e 9 c : `i V � �, r� ,,,y$�� � l -N"w j ��^ k-� 4� wS`}r� S� n { ]� 4..a$. 1 �R3�3��.`i x iS'Y i'.{ h%.�„L^1 f D k 3 ._.,.>v_.�...:tu„�...'......,s..,-.G...;x.._.._.<,..-.€Nc.:�....��,.,."�._..,......c,....r.;� Jryijj aLaer-;,aryit�` BCIS Home ; Log In ' User Registration Hot Topics Submit SurchargF&fpcts &6bllications FBC Staff BCIS Site Map Unks Search Business/ t = Profess&al V }Product Approval USER: Public User Lk COPY Regulation Product AODroyal Menu > Product or Aoolication Search > Aonlication List, > Application Detail FL # FL10674-116 Application Type Revision Code Version 2010 Application Status Pending FBC Approval Comments Archived Product Manufacturer Owens Coming Address/Phone/Email One Owens Coming Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greq.keeler@owenscoming.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscomig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Robert J.M. Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity Underwriters Laboratories Inc. Quality Assurance Contract Expiration Date 09/26/2014 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10674 R6 COI Trinity ERD CI - Nieminen.odf Referenced Standard and Year (of Standard) Standard Year ASTM D3161, Gass F 2006 ASTM D3462 2007 ASTM D7158, Class H 2O07 Equivalence of Product Standards Certified By h"://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V %2... 3/29/2012 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/16/2012 Date Validated 02/21/2012 Date Pending FBC Approval 02/24/2012 Page 2 of 2 FL JIMlodel, Number or Name IDescription 10674.1 Owens Coming Asphalt Roofing 3-tabr laminated, starter, and hip & ridge Shingles and Starters Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER, Section 5. Installation Instructions FL10674 R6 II er020612FINAL OC FL10674- R6 Asphalt Shinoles.pdf Verified By: Robert J. M. Nieminen PE - 59166 Created by Independent Third Party: Yes Evaluation Reports FL10674 R6 AE er020612FINAL OC FL10674- R6 Asphalt Shinoles.odf Created by Independent Third Party: Yes Sadc Nezi Contact Us,.,. 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coovriaht 2007-2010 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions regarding DBPR's ADA web accessibility, please contact our Web Master at webmaster@dbpr.state.fl.us. Product Approval Accepts: EE�ECt �cvrit�-�i r i :r• x vari5ign � rry Fed r httD://www.floridabuUdin,.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2... 3/29/2012 Certificate of Authorization #9503 August 01, 2011 RE: Certification of Independence, Florida F.A.C. Rule 9N-3 To Whom It May Concern: This letter serves to document the following in accordance with Florida F.A.C. Rule 9N-3: I . Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Please contact our office with any questions. Sincerely, Robert Nieminen, P.E. Florida Reg. No. 59166 Vice President Email: robertnieminen@trinityerd.com EXTERIOR RESEARCH Ii; DESIGN, LLC. d/b/a TrinitylERD —Certificate of Authorization #9503 MAIN: 80 Yesler Way . Suite 200 . Seattle, WA 98104 . P: (206) 467-0054 . F: (206) 467-5840 EAST: 353 Christian Street Unit 13 . Oxford, CT 06478 . P: (203) 262-9245 . F: (203) 262-9243 FVOL"ATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 037940.Uz.iz FL10674-R6 Date of Issuance: 02/06/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify, Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityIERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: 0 Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/06/2012 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity IERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of'the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07 3. REFERENCES: Entity Examination Reference Date UL (CER1739) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL (TST1740) Physical Properties 06CA20263 04/18/2006 Miami -Dade (CER1592) FBC HVHZ Compliance 07-1116.12 02/14/2008 Miami -Dade (CER1592) FBC HVHZ Compliance 09-0915.12 12/16/2009 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.09 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.10 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.08 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 10-0817.07 10/27/2010 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0411.03 06/16/2011 Miami -Dade (CER1592) FBC HVHZ Compliance 11-0919.05 10/13/2011 UL (QUA1743) Quality Control Service Confirmation Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic° and Supreme@ are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Duration°, Duration° Premium, Oakridge® and WeatherGuardO HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuarde HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization *9503 FL10674-RG Date of Issuance: 02/06/2012 Page 2 of 6 I TRINITY- ER® 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to V,,d = 150 mph (Vi,(t = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire® shingles require minimum five (5) nails per shingle. ➢ WeatherGuard`9 HP shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing — Classic@ & Supreme: Normal Mansard or Area pars Wind Areas High Wind dosvenos y Area pars vionros normaios Areas vionros fuerres rt' (AI 5'Exposure Exposition Exterior Research and Design, LLC. Certificate of Authorization #9503 Normal Mansard or Area pare Wind Areas High Wind desvunes y Area pare vienros normaias Areas vientos fuertos ttz t �lAl\ rz t t (BI I r 6 5/8' Exposure Exposition Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 Page 3of6 6.2.6 Minimum Nailing — Berkshire®: Sealant strip La 1ha de sedadar o e -t A ti' 9 Yt' 9 SPC 1 A Yt' Sealantslap !a grade Sander La w ey Sw a yr t. J e Zr" Asphalt roofing cement Cameato de techo de Malta 6.2.7 Minimum Nailing — Duration® & Duration® Premium: 4 Waft Pattern Esquema de 4 davos SuwNagattstening area width Area de dowsSureNaiP r r n• tY 5 n" Exposure Nags Exposure 6b purg. de exposicvn Claws 6%puig. de exposfcrdn 6.2.8 Minimum Nailing — Oakridge®: 4 Nail Pattem aquema Cott 4 Claws t• t• 14— >z• •--IDI Imo— ,Y —�I �L�a V---� 5 5f8" Exposure Malls 5 5/8" Exposure Fxposiddn de 6 USpidg Cray, Expos1d6nde69/2puig. Exterior Research and Design, LLC. Certificate of Authorization #9503 6 Nag #lin klcpithu0�ado Pattern wanatce m cut ova. Esquema — Iiars;rUa al,�iE.Nes deSdavos t afio'Zipp, a7 O xpoor tl ramb.m!a '1 rraaiu rklraa7a sunuaT \ Sdran' auaw'die fnilK � Uslmin9 'arretsicin A-Ua t" � \1 F�in0 Soria �' �— 1T —� ` �E— 77' ' Sm to uifa 5T Exposure Nails 5Ye' Exposure 5t5 pufg. do o(posirrdn Clawn SSi purg. do mposidaa 6 Nail Pattern Esquema colt S Caws t` t" NaiLq 5 5f8" Exposure Craves 5 518" P P$= Evposfddn de 66/8poig. Exposwa de 66/6 purr. Evaluation Report 037940.02.12 FL10674-R6 Date of Issuance: 02/06/2012 Page 4 of 6 6.2.9 Minimum Nailing — WeatherGuardp HP: 81o& era. VkW ilCrri L�6srai dw��oiallr6l�rJir 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant and WeatherGuardO HP Hip and Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 6.3.3 6.3.4 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Minimum Nailing — Berkshire® Hip & Ridge and High Ridge: Minimum Nailing — Hip & Ridge with Sealant: item Fig. 2 - High Wind Fasmkg Paftegn K Naols) Trig" Shingle (1=xt-, �..Lr Sealant21 Strip a a 112" ' Fastening 6'Y, 5 Exposure 12 v Fig. 2 Tallifim SWUM �i Nail'ss Nails Z I T pLaninated PiI Z { ece ' t' 0 I I m� �I —I UI I I I I Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-116 Date of Issuance: 02/06/2012 Page 5 of 6 6.3.5 Minimum Nailing - WeatherGuard® HP Hip and Ridge: Fig. A 4 4 Prevalling Wintl A 11011r. 4 0 I I A\ p I I I I I I I I A I I I I I I I I Exposure 7. LABELING: Fig. C Hip & Ridge Shingle Fastening Top Merl T' 2" 2" �. 1. Exposure 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: Underwriters Laboratories - QUA1743; (414) 248-6409; karen.buchmannaui.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12 Certificate of Authorization #9503 FL10674-116 Date of Issuance: 02/06/2012 Page 6 of 6 Florida Building Code Online r_, Page 1 of 2 t r 4 SCIS Home i Log In ! User Registration , HotTopics i Submit Surcharge i Business ,7 ProdProfessional ffixUSER:PubicUser al 20 Sets & Facts Publications j FBC Staff i BCIS Site Map links 'Search `. Product Approval Menu > Product or Application Search > Application List > Application Detail �t uazT % FL # FL2569-R6 Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Revision 2010 Approved' soprema, Inc. (Canada) 1640 rue Haggarty Drummondville, NON -US 00000 (819)478-2400 Ext3327 memathieu@soprema. ca Marc -Etienne Mathieu memathieu@soprema. ca Marc -Etienne Mathieu 1688 Jean-Berchmans-Michaud Drummondville, NON -US 00000 (819) 478-2400 Ext3327 memathieu@soprema.ca Jean -Francois Cote, Ph.D. 1640 rue Haggarty Drummondville (888) 811-3145 jfcote@soprema.ca Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer V, Evaluation Report -Hardcopy Received Robert J. M. Nieminen PE-59166 UL LLC 11/30/2014 John W. Knezevich, PE Validation Checklist -Hardcopy Received FL7569 R6 COI Trinity EP.D CI -Nieminen - 2013.odf Standard Year ASTM D1623 2009 ASTM D1970 2001 ASTM D6163 2000 ASTM D6164 2005 FM 4474 2004 FRSA/TRI07320 2005 TAS 103 1995 TAS 110 2000 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 10... 12/6/2013 Florida Building Code Online Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 05/22/2013 Date Validated 06/12/2013 Date Pending FBC Approval 06/12/2013 Date Approved 08/23/2013 Summr_ ary of Products FL # Model, Number or Name Description 2569.1 Soprema Roof Self adhering roof underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL2569 R6 II er052213FINAL SOPREMA CA UNDERLAYMENTS FL2569- R6. Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen, P.E. PE-59166 Design Pressure: +N/A/-90 Created by Independent Third Party: Yes Other: 1.) Refer to ER Section 5 for Limits of Evaluation Reports Use. 2.) The design pressure noted herein FL2569 R6 AE erO52213FINAL SOPREMA CA UNDERLAYMENTS FL2569- R6.DdF pertains to underlayment systems used beneath adhesive -set tile systems. Refer to Created by Independent Third Party: Yes ER Section 5.5.4 for details. Bade Wezt Contact Us :: 1940 North Monroe Street Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455, F.S., please dick here . Product Approval Accepts: Et-t http://www.floridabuilding.org/car/car app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 10... 12/6/2013 r TRINITY! ERD EVALUATION REPORT Soprema, Inc. 1640 rue Haggerty Drummondville, Qu6bec 32C 5P8 Canada EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report S18010.06.09-114 FL2569-RG Date of Issuance: 06/15/2009 Revision 4: 05/22/2013 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert 3.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 05/22/2013 This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. A ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2004 1507.2.4, 1507.2.9.2, Physical Properties ASTM D1970 2001 1507.5.3 1507.11.2 Physical Properties ASTM D6163 2000 1507.11.2 Physical Properties ASTM D6164 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 1523.6.5.2.17.3 Tensile Adhesion ASTM D1623 2009 TAS 110 Accelerated Weathering TAS 110 2000 1507.3.3 Installation Practice FRSA/TRI 07320 2005 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) ASTM D1970 / TAS 110 2968.05.04-2 05/14/2004 ERD (TST6049) Physical Properties 2757.02.05 02/03/2005 ERD (TST6049) ASTM D1970 / TAS 110 2974.03.05-2 05/17/2005 ERD (TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD (TST6049) Wind Resistance 2779.11.05-R1 04/18/2007 ERD (TST6049) TAS 103 / TAS 110 S7120.11.07-2 11/02/2007 ERD (TST6049) ASTM D1970 / TAS 110 S13190.02.09-111 04/01/2010 ERD (TST6049) ASTM D1970 / TAS 110 S31370.03.10-1-R1 04/07/2010 ERD (TST6049) Physical Properties / Tensile Adhesion S11150.05.10-R1 09/09/2010 ERD (TST6049) Physical Properties / Tensile Adhesion S11150.05.09-R2 10/05/2010 ERD (TST6049) ASTM D1970 S37210.11.11 11/09/2011 ERD (TST6049) ASTM D1970 S40540.02.13-1 02/19/2013 M-D (CER1592) HVHZ Compliance 09-1005.02 11/04/2010 M-D (CER1592) HVHZ Compliance 11-1206.04 03/15/2012 ICC-ES (EVL2396) 2012, 2009 and 2006 IBC Compliance ESR-1524 03/01/2013 UL, LLC (QUA9625) Quality Control Service Confirmation Exp. 11/30/2014 4. PRODUCT DESCRIPTION: 4.1 LAsrOBOND TU is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment. 4.2 LAsrOBOND SHIELD is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch. 4.3 LAST060ND SHIELD HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. 4.4 LASTOBOND PRo HT-N is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch. 4.5 LAsrOBOND PRo HT-S is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. Exterior Research and Design, LLC. Evaluation Report S18010.06.09-R4 certificate of Authorization #9503 F1_2569-116 Revision 4: 05/22/2013 Page 2 of 8 f � II CITY�ERD 4.6 LASTOBOND 195 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment. 4.7 LAsToBOND is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment. 4.8 LAsToBOND Eco is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment. 4.9 LAsToBOND SMOOTH SEAL HT is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underlayment. 4.10 REslsro EcoNo is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment. 4.11 RESIsTo LB1236 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheet width. 4.12 PRIMESOURCE GRIP -RITE EAVE & VALLEY PROTECTOR is a Self -adhering, glass -mat reinforced, sand - surfaced, SBS modified bitumen roof underlayment, with a. 36-inch sheet width. 4.13 EcoSTAR, LLC. GLACIER GUARD 100 is a self -adhering, glass -mat reinforced, sand surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheet width. 4.14 REsisTo LB1244 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 44-inch sheet width. 4.15 COLPHENE FR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof underlayment. 4.16 UNILAY (E) is a mechanically attached, polyester reinforced, granule -surfaced, SBS modified bitumen roof underlayment: S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underlayments are follows: Table 1: Roof Cover Options Underlayment Asphalt Nail -On Foam -On Metal Wood Shakes Slate Shingles Tile Tile & Shingles Lastobond TU Yes Yes No No Yes Yes Lastobond Shield / Pro HT-N Yes No No No Yes Yes Lastobond Shield HT / Pro HT-S Yes No No Yes Yes Yes Lastobond / Lastobond 195 Yes No No No Yes Yes Lastobond ECO / Resisto Econo / Resisto LB1236, Grip -Rite Eave & Yes No No No Yes Yes Valley Protector or Glacier Guard 100 / Resisto LB1244 Lastobond Smooth Seal HT Yes No No Yes Yes Yes Colphene FR GR Yes Yes See es5. No Yes Yes Unilay (e) Yes Yes I Batten Only1. Yes See 5.4.1 No No No Exterior Research and Design, LLC. Evaluation Report S18010.06.09-R4 certificate of authorization #9503 FL2569-R6 Revision 4: 05/22/2013 Page 3 of 8 ER.D 5.4.1 "Foam -On Tile" is limited to use of 3M 2-Component Foam Roof Tile Adhesive AH-160 unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. 5.5 Allowable substrates are noted below: 5.5.1 Direct -Bond to Deck: Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT or Lastobond Pro HT-S applied to: ➢ Plywood; ➢ ASTM D41 primed plywood; ➢ OSB; ➢ ASTM D41 primed OSB; ➢ Southern Yellow Pine; ➢ ASTM D41 primed Southern Yellow Pine; ➢ ASTM D41 primed structural concrete. Lastobond TU, Lastobond, Lastobond 195, Lastobond ECO, Resisto Econo, Resisto LB1236, Grip -Rite Eave & Valley Protector, Glacier Guard 100, Resisto LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood; ➢ ASTM D41 primed plywood. Colphene FR GR applied to: ➢ Plywood; ➢ ASTM D41 primed plywood; ➢ ASTM D41 primed structural concrete. Note: ➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.5.2 Bond -to -Insulation: Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT, Lastobond Pro HT-S or Colphene FR GR applied to: ➢ DensDeck DuraGuard; ➢ DensDeck Prime; ➢ SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam, on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D or TAS 114, Appendix I 5.5.3 Bond to Mechanically Attached Base Layer: Lastobond Shield, Lastobond Pro HT-N, Lastobond Shield HT, Lastobond Pro HT-S or Colphene FR GR applied to: ➢ ASTM 13226, Type I or II felt; ➢ Sopra-G; ➢ Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. Exterior Research and Design, LLC. Evaluation Report S18010.06.09-R4 Certificate ofAuthorization #9503 FL2569-RG Revision 4: 05/22/2013 Page 4 of 8 4, z 9 ERD 5.5.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. 5.5.4.1 Maximum Design Pressure = -45.0 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) Elastocol Stick or Elastocol 600c Underlayment: Colphene FR GR, self -adhered. 5.5.4.2 Maximum Design Pressure = -67.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: Elastocol600c Underlayment: Colphene FR GR, self -adhered. 5.5.4.3 Maximum Design Pressure = -60.0 pst. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three, equally spaced rows in the center of the sheet. Underlayment: Colphene FR GR, self -adhered 5.5.4.4 Maximum_Desion Pressure = -90.0 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ. Underlayment: Unilay(e) mechanically attached with Soprafix Polymer Batten Bar (PBB) or Soprafix Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6- inch o.c, within the 5-inch wide, self -adhering side laps. End laps are 6-inch wide and sealed using either heat -welding or hot-air welding techniques. 5.6 Exposure Limitations: 5.6.1 Lastobond TU, Lastobond Shield, Lastobond Pro HT-N, Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, Resisto Econo, Resisto LB1236, Grip -Rite Eave & Valley Protector or Glacier Guard 100 or Resisto LB1244 shall not be left exposed for longer than 30- days after installation. 5.6.2 Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation. 5.6.3 Colphene FR GR or Unilay(e) shall not be left exposed for longer than 180-days after installation. 5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief titled "Florida High Wind Roof Tile Self -Adhered Underlayment Requirements as of 02/14/2011" for limitations for self -adhering underlayments used beneath tile roof systems. Exterior Research and Design, LLC. Evaluation Report 518010.06.09-R4 Certificate of Authorization #9503 FL2569-116 Revision 4: 05/22/2013 Page 5of8 i iTRINITYIRD Table 2: He S stem Options per FRSA TRI 07320 8-05 System Underlay Option Section Reference Product(s) 3.02A 1 Batten Modified Cap Sheet Unilay(e) System One: only Mechanically Fastened 5 3.02E Self -Adhered Lastobond TU, Colphene FR GR Tile, Unsealed or Underlayment Sealed Underlayment Base Layer: ASTM D226, Type II; System No. 30 / Self -Adhered Sopra-G; Modified Sopra-G 6 3.02F Underlayment Top Layer: Lastobond TU,Colphene FR GR 4 3.02D Self -Adhered Lastobond TU, Colphene FR GR System Two: Underlayment Mechanically Fastened Base Layer: ASTM D226, Type IT; Tile, Sealed No. 30 / Self -Adhered Sopra-G; Modified Sopra-G Underlayment System 5 3.02E Underlayment Top Layer: Lastobond TU, Colphene FR GR 1 3.02A Modified Cap Sheet Unila e System Four "A": 4 3.02D Self -Adhered Colphene FR GR Adhesive -Set Tile, Underla ment No. 30 / Self -Adhered Base Layer: ASTM D226, Type II; Unsealed or Sealed Underlayment System 5 3.02E Underlayment Sopra-G; Modified Sopra-G Top Layer: Colphene FR GR System Four "B": 3 3.02C Self -Adhered Underlayment Colphene FR GR Adhesive -Set Tile, Base Layer: ASTM Type II; Sealed Underlayment 4 3.02D No. 30 / Self -Adhered Modified Sopra-pra-G System Underlayment Tr: Colphene FR GR Toopra Layer: 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick or Elastocol 600c (if applicable). 6.3 Lastobond TU Lastobond Shield Lastobond Pro HT-N Lastobond Shield HT, Lastobond Pro HT-S Lastobond Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Resisto Econo, Resisto 1_131236 Grip -Rite Eave & Valley Protector or Glacier Guard 100, Resisto LB1244 or Colphene FR GR: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 For non -tile aDDlications: 6.3.2.1 While priming is optional, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. 6.3.2.2 Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. 6.3.2.3 Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. 6.3.2.4 Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Exterior Research and Design, LLC. Evaluation Report S18010.06.09-114 CertiFcate of Authorization #9503 FL2569-R6 Revision 4: 05/22/2013 Page 6 of 8 1 TRINITY( ERD 6.3.2.5 Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps shall be sealed using either heat -welding or hot air welding techniques. 6.3.2.6 When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of the sheet at 12-inch o.c. 6.3.2.7 For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 For tile applications: 6.3.3.1 Reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as a guideline. 6.3.3.2 For Colphene FR GR in foam -on the applications, reference is made to Section 5.5.4 herein for wind resistance limitations. 6.3.3.3 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 6.4 Unilay(e): 6.4.1 For non -tile applications or nail -on, battened tile applications: 6.4.1.1 Reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.4.1.2 Apply sheet parallel to the roof edge and, starting at the eave with the selvedge -edge upslope, mechanically attach the 5-inch wide selvedge -edge to the wood deck with nails and tin caps or round cap -nails spaced 36-inch o.c. Apply the second course in a water -shedding manner with self -adhering side -laps. Vigorous hand or motorized roller pressure is applied to the self -adhering laps to ensure a watertight application. 6.4.1.3 Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps shall be sealed using either heat -welding or hot air welding techniques. 6.4.1.4 Tile (if applicable) shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. 6.4.2: For foam -on tile applications: 6.4.2.1 Reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 herein. 6.4.2.2 Apply sheet parallel to the roof edge and, starting at the eave with the selvedge -edge upslope, mechanically attach the 5-inch wide selvedge -edge to the wood deck Soprafix Polymer Batten Bar (PBB) or Soprafix Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. Apply the second course in a water -shedding manner with self - adhering side -laps. Vigorous hand or motorized roller pressure is applied to the self - adhering laps to ensure a watertight application. 6.4.2.3 Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps shall be sealed using either heat -welding or hot air welding techniques. 6.4.2.4 Tile (if applicable) shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. Exterior Research and Design, LLC. Evaluation Report S18010.06.09-R4 Certificate of Authorization #9503 FL2569-116 Revision 4: 05/22/2013 Page 7 of 8 LABELING: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule 9N-3 QA requirements. QUALITY ASSURANCE ENTITY: UL, LLC - QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report S18010.06.09-114 Certificate of Authorization #9503 FL2569-RG Revision 4: 05/22/2013 Page 8 of 8