Loading...
HomeMy WebLinkAboutREVISIONSOFFICE USE ONLY: DATE FILED: '�L 14 11 REVISION FEE: I 5,b a PERMIT # I �IC�3 �d'ot5 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/SITE Riverbend ADDRESS: 13301 NW Baywood Place 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: 3. 4. 5. Lot 27 11 :® f,77 Revised fron entry door D3, transom D3a and window E + CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CGC 15 0 6 3 0 4 ST. LUCIE COUNTY CERT. #: 2 8 4 2 0 BUSINESS NAME: Standard Pacific Homes QUALIFIERS NAME: Michael T. Collins ADDRESS: 825 Coral Ridge Drive CITY: Coral Springs STATE: F1 ZIP: 33071 PHONE (DAYTIME): qq—q7q-73j7 FAX: 954-575-7324 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE: Standard Pacific Homes 825 Coral Ridge Drive Coral Springs STATE: Fl ZIP: 33071 954-575-7337 FAX: 954-575-7324 ARCHITECT/ENGINEER INFORMATION: NAME: AB Design ADDRESS: 1191 East Newport Center Suite 207 CITY: Deerfield Beach STATE: Fl ZIP: 33442 PHONE (DAYTIME): 9554-482 0957 FAX: 954-708-2468 SLCCC: 9/23/09 Revised 04/26/2010 1I A R C H I T E C T S Design Group May 20, 2014 St. Lucie County Building Department 2300 Virginia Avenue Fort Pierce, FL 34982 Attn: Building Plan Processor RE: Standard Pacific Homes Riverbend Lot 27 Permit No. 1403-0250 Dear Sir/Madam, This letter serves as revisions to lot above: 1. Revised front entry door D3, transom D3A and window E. Please see delta 2 on sheets Al, A1.1 and A2C. If you have any questions please contact me at (954) 482-0957. Sincerely, Michael Hurtak Florida Architect #0008374 1 1191 East Newport Center Drive • Suite 207 • Deerfield, FL 33442 • Phone: (954) 482-0957 • Fax: (954) 708-2468 AA0003325 www.abdesigngroup.com Planning & Development Services Department Building & Regulations Division Product Review Affidavit Building Permit # l ui3 - U 2-SO Owners Name Standard Pacific Homes Lot 27 Applicant: Product Opening Design Product Rated Manufacturer Model Number Product Approval Glass Method of Attachment Pressures Design Pressure Number Type Windows +42.5/-57.5 +80/-80 PGT 700 FL-11-1013.14 Impact 2-Tapcon in Head, 5-Jamp Mullions PGT FL-11-0922.01 Fixed Glass +43.9/-47.5 +80/-80 PGT 701 FL-13-0502.03 Impact Tapcons-Max O.0 Spacing 12" Block Glass NA Skylights NA Sliding Glass Doors Swing Type Doors +40 . 0/-43 .6 +50/-50 Jeld-Wen Smooth Pro FL16708.1/.5 Imapct Wood Screws French Doors +34.9/-38.5 +50/-50 Jeld-Wen Smooth Pro FL16708.2 Impact Install w/CBS Const. 1X buck w/ITW 1/4" anchors Garage Doors +40.4/-36/8 + Amarr 950 13-0503.6/.8 Impact 2 X 6 Vertical wood jam attachment to 2000 PSI Concrete using NA Hitli quick bolts Hurricane Protection Roof Ventilation Roofing Material NA P(1) -39.1 P(2) -68.1 EagleCapistranoFL7473.R5 9 9 NA Mechanically (2) #8 2 1/2" Screws P 3 -100.7 I have reviewed the above components or cladding and I have approved their use in this structure. These r cts rovide adequate resistance to the wind loads and forces specified by current code provisions. Name: Gary McDougle, PE Design Prof: Specialty Engineering Consultant, Inc. Cert. NO. El Boynton Beach, FL 33426 (561) 752-5440 FL CA# 009217 Signature:00000W.Jseal Date: -2nig_ F f OFFICE USE ONLY: Ew^ N DATE FILED: AM 0 � 2u— o� REVISION FEE: PERMMING 1. 2. 3. 4. PERMIT # So RECEIPT # PLING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE Riverbend ADDRESS: 13301 NW Baywood Place 1403-0250 DETAILED DESCRIPTION OF PROJECT REVISIONS: Change in Roofing attachment to Eagle Seal Underl UUIN I KAU I UK llN2' UK1VIAI WIN: STATE of FL REG./CERT. #: CGC15063 04 ST. LUCIE COUNTY CERT. #: 28420 BUSINESS NAME: Standard Pacific Homes QUALIFIERS NAME: Michael T. Collins ADDRESS: 825 Coral Ridge Drive CITY: Coral Springs STATE: F1 ZIP: 33071 PHONE (DAYTIME): qa 4- F 7 5— 7 g q 7 FAX: 9 5 4- 5 7 5- 7 3 2 4 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE: Standard Pacific Homes 825 Coral Ridge Drive Coral Springs STATE: F1 ZIP: 33071 954-575-7337 FAX: 954-575-7324 5. ARCHITECT/ENGINEER INFORMATION: NAME: AB Design ADDRESS: 1191 East Newport Center Suite 207 CITY: Deerfield Beach STATE: F1 ZIP: 33442 PHONE (DAYTIME): 954-482-0957 FAX: 954-708-2468 SLCCC: 9/23/09 Revised 04/26/2010 M1AK WIN DEPARTMENT OF REGULATORY -AND ECONOMIC RESOURCES .(RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF M Eagle Roofing Products, LLC. 1575 E. C R 470 Sumterville, FL. 33585 I I a MIAMI=DARE COUNTY PRODUCT CONTROL SECTION 11905 SW 26 Street; Room208 Miami, Florida 33175-2474 T (786) 315459011 F (786j 315-2599 SCOPE: This NOA is being issued under the. applicable rules and regulations governing the use -of construction -materials. The documentation submitted has been reviewedand accepted by Miami -Dade County RER - Product Control Section to be used, in Miami Dade County and other areas where allowed by the Authority Having. Jurisdiction (AHJ). 1 This NOA shall not be valid after the expiration date stated below: The Miami -Dade County Product Control' Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality,assurance purposes. If this product or material fails to perform in the accepted. manner, the manufacturer will incur the expense of such testing and the.AH7 may immediately, revoke, modify, or suspend the use of such product or material within their jurisdiction. RERreserves the -right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building. code. This product is approved as described herein; and has been designed to comply with the Florida Building Code including the High Velocity'Hurricane Zone of the Florida Building Code. DESCRIPTION: Eagle Seal Underlayment LABELING: Each unit shall bear a permanent label with the manufacturers name or logo; city, state:and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. I RENEWAL of this NOA shall be considered aftera renewal application has been filed and there has been no change in the, applicable building code negatively affecting the performance of this product. i TERAMATION of this NOA will occur after- the expiration date or if there has been a revision .or change in the materials, use, and/or manufacture of the product or process. Misuse of this,NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminatethis NOA. Failure, to comply with any section of this NOA shall be cause for termination and removal of NOA. 1 i ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County; Florida, and followed by the expiration date may be displayed in advertising literature. If any portion. of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided.to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building a This NOA revises NOA# 11-1011.05 and consists of pages 1 through 4. 01 0 a " The submitted documentation was reviewed by Alex Tigera. at H id 1;9-ff , V d r. MIAMI-DARE COUNTYIE NOA No� : 12-0507.03 Expiration. Date: 03/03/15 Approval.D'ate: 09/05/13 Pagel of 4 I i ROOFING COMPONENT APPROVAL Caterory Sub-Cateeory Material: Roofmg Underlayment SBS TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Eagle Seal 3' x 33.4' rolls TAS 103 Self -'adhering, non -woven fiberglass mat 3' x 66.8' rolls reinforced membrane for use as an 3' x 72' rolls underlayment in high temperature sloped. roof assemblies. i MANUFACTURING PLANT(S): j 1. Tuscaloosa, AL j EVIDENCE SUBMITTED: Test Agencv Test.Identifier Test.Name/Repor t' i Date PRI Construction Materials Technologies BWR 514-02-01 (rev) ASTM D 1970 _ 09/04/09 VRMI=Ol 1-02-01 ASTM D 19.70 03/30/09 BWR-511-02-01 ASTM D 1070 j 09/29/09 'BWR-511-02-01 ASTM D 4798. 09/29/09 BWR-522-02-01 ASTM. D 1970 01/16/10 BWR-513-02-01 TAS 103 4 02/19/10 BWR-518-02-01 TAS 103 1 02/19/1"0 BWR-533-02-01 TAS 103 1 09/07/12 9WR-534-02-01 ASTIVI D 1970 09/07/12 1 I MMt•DADe COunrnr NOA Nof: 12-0507.03 Expiration Date: 03/03115 Approval Date: 09/05/13 Page 2 of 4 j Y i APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. i Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626 with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. * In the Non-HVHZ area a Base Sheet is optional. Membrane: One or more plies of Eagle Seal underlayment with a minimum 3 side lap and 6" end lap. i Surfacing: Approved Roof Assemblies. See Limitation #3. i FILECOPIY' NOA No.: 12-0507.03 Expiration Date: 03/03/15 Approval I 'ate: 09/05/13 Page 3 of 4 Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance Project Name: U'cr Project Address: 13301 KW Permit #: ( `fu3 - U 2Z� Occupancy Type Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida ,P>SrCi,grlIa Code 2010 Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed Partially Enclosed Open 3. Risk Category: _I -AlI III _ 4. Design Wind Velocity I M mph 5. Mean Roof Height ft _IV Exposure Category: 1—B C D ASD �6LRFD End Zone Width: �, Jr ft Roof Pitch: 4- :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings : Zone 1: 3 8 zone 2: ,8 zone 3: _� a - g -�, 0 Zone 4: �; �,3 Zone 5:�£-,31�4 Garage: 3Z � 7. Design Loa s: Floor: d PSF Roof/Dead: PSF Roof/Live: 3 0 Balcony: � 6 PSF Dock: � PSF Deck: � PSF Stairs: 4- PSF Fence: I PSF Railings: �PSF � � � g 8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? k Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: dsoc PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: „ Signature, Date`, -',and Seal . JUN 02 Print Name Gary McDougle, PE Cert # & Co. Cert Auth. Specialty Engineering Consultant, Inc. 1599 SW 30th Ave., Suite 20 Buyl rl deach, FL 33426 (561) 752-5440 201 FL PE# 056214 ompany Name & A dress 009217 SLCCDV Form # 020-12 Revised 3%15/12 (JS) LIlm mnoNS: 1.. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. Eagle Seal underlayment shall be installed in strict compliance with applicable Building Code. I 3: Eagle Seal underlay ment yment may be used in asphaltic shingles; metal panels, wood shakes and shingles, quarry slate, and tile roof assemblies (mortar, adhesive, and mechanicailyset), j 4. Eagle Seal underlayment shall not. be applied' over an existing roof membrane; as a recover,! but may be applied overa. roofing.-Base/Anchor sheet underlayment. 5.. Eagle Seal underlayment shall not be left exposed as a temporary roof for longer than 90 days oflapplication. 6. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of thisproduct with specific prepared roofing products. 7. Eagle Seal underlayment may be used with any approved roof covering Notice of Acceptance listing Eagle Seal. underlayment as a component part of an assembly in the Notice of Acceptance. If Eagle Seal underlayment is not listed, a request may be made to the Authority Having, Jurisdiction (AHJ) of the Miami - Dade County Product Control Department for approval provided that appropriate. documentation: is provided to detail compatibility of the products, wind -uplift resistance, and fire testing results. 8. Eagle Seal underlayment'shall be applied to a smooth, clean and dry surface with deck. free of irregularities. All nails in the deck shall. be carefully checked,for protruding heads. Re -fasten any loose deciing.panels. Sweep the deck. thoroughly to remove any dust and debris prior to application. 9. When applying the membrane in the valley, start, at the low point: and work to the high point;. rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward 'in both directions. I 10. Roll or broom the entire membrane surface so as to have 100% contact with the surface; giving special attention to overlap ,areas. i 11. Flash vent pipes, stacks, chimneys and penetrations in _compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 12. All protrusions or drains shall be initiallytaped with a; 6" p piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit.. A_ second layer, of Eagle Seal underlayment shall.be applied over the underlayment. 13. All products listed herein shall have a quality assurance audit in accordance with the Florida Building; Code and Rule 9N-3 of the Florida Administrative Code. 14. All membranes or packaging shall bear the imprint or identifiable marking: of the manufacturer's name or logo and. the following: statement: "Miami -Dade County Product Control. Approved" or the Miami -Dade: County Product Control Seal as shown below. MM MI•DADE.COUNTY END OF THIS ACCEPTANCE CM•DADECOUNrr NOANol: 12-0507.03 Expiration Date: 03/03/15 Approval. Date: 09/05/13 Page 4 of 4