HomeMy WebLinkAboutSUBMITTED PAPERSDate:
❑ Electrical
❑ Shed*
Fee Due:
Planning & Development Services
Building & Code Regulations Division
2300 Virginia Ave.
Fort Pierce, FL 34982
(772)462-1553 Fax 462-1578
SPECIALTY PERNUT APPLICATION
❑ Plumbing ❑ HVAC ❑ Fence
❑ Demolition ❑ Gas ❑ Siding
Seepage 2 for instructions and additionalpaperwork required for specialty permits
1. Location/Site Address: g C) �( 9 L;IJIC S
2. Parcel ID Number: 3 3,-) / - 71D — 0 t) 4-1 ^ 0 0 0
3. Complete Description of Project or Work:
4. Owners Information 5. Contractors Information Name: J OC-' IDA U/ A FL Reg/Cert #: CIL S ' 6O /�}
Address: �� �� C/ 4�ks t'-"A y County Cert#: 25 7 2 2-
City: P• S - L - State: F1 Business Name: TRA C1C W lii SO(A2
Zip: 3 ! C? A Phone: 3 � y 3�Z Z Phone: L H'14 3 OFax: .3V-6133
6. Value of Construction: $ 21 / 0
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in
compliance with all applicable laws regulating construction and zoning.
IDA U e il) OOA/
PRINT OWNER OR CONTRACTOR NA iME . SIGNATURE OF OWNER OR CONTRACTOR
STATE OF FLORIDA, COUNTY OF 8��hUG�
ACKNOWLEDGED BEFORE ME THIS C gO DAY OF 2Q � , BYE� 11 0V pp (_t'
WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED qi�NL# D 9 1 Pq - d
LASHAHNAINGRAM
NT CATI � F My COMMISSION 8 EE 050558
-,qf';��' BondetfTh December 20, 2014
SI A URE OF NOTARY TYPE O PRINT NAME 44TARY
„ Notary Public Underwriters
COMMISSION NUMBER
*ALL RESIDENTIAL AND NONRESIDENTIAL STRUCTURES ARE REQURIED TO MEET THE FLOOD ZONE
ELEVATION OR 18 INCHES ABOVE THE CROWN OF THE ROAD, WHICHEVER IS APPLICABLE. (see instructions on
reverse side of this sheet)
Revised 04/17/2014
NOTICE TO OWNER: FAILURJ� ') RECORD A NOTICE OF COMMENCEMENT,_—' Y RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7,500.00
INSTRUCTIONS
Please complete all information in the space provided. All information must be printed (use black or blue ink
only) or typed. This permit application is to be used only for those activities that are not otherwise included
under a primary building permit. This application may not be used for any activity that includes structural
alteration. The information to be provided with this application includes:
1. Location/Site Address
2. Parcel ID Number ,
3. Description of Project or Work Activity
4. Owner Information
5. Contractor Information
6. Value of Construction
Indicate the street address or general location of
property where the building activity is taking place.
Indicate the tax identification number of the
property where the building activity is taking place.
Fully describes the activity to take place.
Indicate the name and address of the owner of the
property on which activity is taking place.
Indicate the State of Florida registration number (if
applicable), St. Lucie County contractor license
number and the name of the business doing the
work.
Indicate the total value of the work to take place.
Total cost of constructiop includes all, current retail
material and labor costs associated with the
'bdilding/construction activity. Construction value is
used to determine the permit fee. St. Lucie County
reserves the right to question and/or modify the
..indicated value of construction if it is demonstrated
that the submitted figures are not consistent with
similar types of construction.
❑ Gas Attach 2 piping schematics with tank size, location, and BTU of each appliance
❑ Shed: Attach 2 plot plans, 2 copies of DCA letter and plans, 2 anchor specifications
❑ Fence Attach 2 plot plans showing location of fence height of fence and type of fence
r
❑ Siding Attaclil copies of manufactures specifications
❑,HVAC No attachments necessary
This:application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce,
FL,34982. All permit applications must be filled out completely before submission. No applications will be
accepted for processing after 4:30 P.M. For assistance in completing this application,, please call (772)
462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday.
Upon issuance of this permit, required inspections can be scheduled by calling 1-866-284-1280 or logging on to
http://codeinspectionpublic.stlucieco.gov/
FLORIDA SOLAR ENERGY CENTER®
SUMMARY INFORMATION SHEET
V September 2010
FSEC # 00362C
MANUFACTURER
Collector Model
'*Aquatherm Industries, Inc. Ultraswim 16045-10
1940 Rutgers university Blvd
Lakewood, NJ 08701
This solar collector was evaluated by the Florida Solar Energy Center (FSEC) in accordance with prescribed methods and was found
to meet the minimum standards established by FSEC. This evaluation was based on solar collector tests performed at the Florida
Solar Energy Center, Cocoa, Florida. The purpose of the tests is to verify initial performance conditions and quality of construction
only. The resulting certification is not a guarantee of long term performance or durability.
DESCRIPTION
Gross Length 3.048 meters 10.00 feet
Gross Width 1.19 meters 3.92 feet
Gross Depth 0.049 meters 0.161 feet
Gross Area 3.627 square meters 39.20 square feet
Transparent Frontal Area 3.627 square meters 39.20 square feet
Volumetric Capacity 12.63 liters 3.336 gallons
Weight (empty) 9.208 kilograms 20.30 pounds
Recommended Flow Rate 252 ml/s 4.0 . gpm
Test Pressure 241 kPa 35 psig
Number of Cover Plates None
Flow Patter 104
Number of Tubes
MATERIALS Lo
Enclosure None
Glazing None
Absorber Co -polymer plastic with UV stabilizationFILE t;,s
Absorber Coating None COa
Insulation (Side/ Back) None
THERMAL PERFORMANCE
r
Testing per ASHRAE 96-1980 (RA 1989)
Incident Angle Modifier Kra = 1.0 - 0.03 ([I/cos 01— 1)
Efficiency Equations
SI Units °C / Watt/& English Units OF / Btu/hr-W
11= 85.8 - 1943 (T� T /I rl = 85.8 - 342 (Ti Ta)/1
q = 86.3 - 1821 (T; Ta/I - 5229 [(Ti-TJ/IJ2 11= 86.3 - 320 (T; T j/I - 162 [(T; Ta/112
RATING
This collector has been rated for energy output on measured performance and'an assumed standard day. Total solar
energy available for the standard day is 5045 Watt-hour/m2 (1600 Btu/ft2) distributed over a 10 hour period.
Output energy rating for this collector based on the second -order efficiency curve are:
Collector Temperature ENERGY OUTPUT
Low 35 °C (95 °F) 41200 Kilojoules/day 39100 Btu/day
Intermediate 50 °C (122 °F) 15500 Kilojoules/day 14900 Btu/day
High 100 °C (212 °F) 0 Kilojoules/day 0 Btu/day
Reference 92025
1679 cLEAR An RoAn, C000A, FLox1DA 32922-5703 ■ TEL 371-638.1000 - FA021.638-1010 - ww-%fsec.ucf edu _
1 Im x9WV r.VaFM nF FLamm ■ AN Ea ves CXPoRmnw/AFFO-ATn/E ACnON EMnaiFR - A RE SFARCH iNmnm oFTHE UNnomw of CENTRAL FLo1LOA
ACCEPTABLE ALTERNATE
EXTEND THRU TO SHEATHING BELOW
ADD SEALENT AT CONNECTION
PROVIDE TAPCON SCREWS OF
ADEQUATE LENGTH TO SECURE
BRACKET TO CEMENT TILE.
DRILL HOLE THRU CONC. TILE
AND INSTALL TAPCON SO AS
NOT TO BREAK TILES.
1/4' LAG ACCEPTABLE ALTERNATE OR
#14 PHIL PAN OR HEX HEAD ACCEPTABLE ALTERNATE
S-5 CLAMP S-5 CLAMP
3" PANEL 'I to
.032 THICK
STANDING SEAM CONNECTION
ALL H ay"I E STiNKM OR a"
PANELS SHALL NOT BE
.—TAI I Cn Im CnoMrP 70NFS
PERCENT OF MEAN HEIGHT, OR 3 FT.
WHICH EVER IS SMALLER.
4'x8', 10' or 12'
solar panels
upper hold down
clamp eee detail A'
M 1
PLEASE N01E: LONER CLAMP/SPRING ASSEMBLY
MAYBE 01 PROVIDED A C041IN000S CROSS STRAP
IS INSTALLED NO MORE THAN 12 ABOVE LONER/RETURN
ASSEMBLY
ROOF LAYOUT GENERAL CONDITIONS
PANEL 0 # 14X 1 1/2'PAN HEAD
_OR HEX HEAD SCREW.
ROOFING
•OD
SHEATHING
upper clamp assembly detail A
PANELS
LOWER/RETURN ASSEMBLY
LOWER hold down
clamp see detail B
1. THE SOLAR COLLECTOR INSTALLATION
AS DETAILED IN THE DRAWINGS IS
FOR THE INSTALATION OF POTABLE WATER
HEATING SYSTEMS ON STRUCTURES
UP TO 35 FEET IN HEIGHT WITH ROOF
SLOPES BETWEEN 0 AND 30 DEGREES,
ROOF AREAS 1 AND 2 BUT NOT CORNERS.
2. THE DESIGN OF THIS INSTALLATION IS
BASED ON ASCE7-10 FOR SURFACE
AREAS BETWEEN 20 AND 48 SQUARE
FEET RESULTING IN A MAXIMUM WIND
PRESSURE OF <= 67 PSF.
THE INSTALLATION SHALL UTILIZE HARD—
WARE PROVIDED BY THE MANUFACTURER
AS DETAILED IN THE INSTALATION
MANUAL OR AS SHOWN ON PLAN.
1/2' O.S.B OR PLYWOOD_)
ROOF DECKING
STRAP BRACKET
SPRING ASSEMBLY
AT CONTRACTORS OPTION
# 14X 1 1/2"PAN HEAD
IOR HEX HEAD SCREW.
/ ROOFING
\ rm
MIN.1/2' O.S.B. OR PLYWOOD
SHEATHING
lower clamp assembly detail B
NOTE: LOWER CLAMP/SPRING ASSEMBLY MAY BE DELETED PROVIDED
BOTTOM CONTINUOUS STRAP IS LOCATED WITHIN 12' OF BASE
MOUNTING BRACKET
STRAPPING
IT&I
PROVIDE #12 SCREWS W CON!
ADEQUATE LENGTH TO SOUR
BRACKET TO CEMENT TILE.
DRILL HOLE THRU CONC. TILE
AND INSTALL SCREW SO AS
NOT TO BREAK TILES.
PANEL
RISER SYSTEM
14X 1 1/2-PAN HEAD
OR HEX HEAD SCREW.
ROOFING;.
— MIN.1/2'
CL&B, OR PLYWOOD
SHEATHING
RAFTER
DETAIL c REVIEWED
FOR 00MBp -c s
REVIEWS0 By
rwe
CONC. BARREL/FLA
TILE
TILE ROOF NOTE
ENSURE TILE CAVITY IS FILLED COMPLETLY
WITH DOW TILE BOND ROOF TILE ADHESIVE
OR EQUAL APPLY ADHESIVE TO TILE AQUA THERM
MOUNTING BRACKET IS ATTACHING TO PLUS ALL
TILES AROUND IT (5) MINIMUM.
WWI KNP3 i5ii*? J0 OR
i iN§PRtifb_ N WILL. 30 MADE
FLORIDA BUILDING CODE 2010
ULTIMATE DESIGN WIND SPEED: 180
NOMINAL DESIGN WIND SPEED: 140 2
RISK CATAGORY:
IMPORTANCE FACTOR: 1.0
EXPOSURE CATAGORY: C
INTERNAL PRESSURE COEF: +-0.18
ENCLOSED STRUCTURE
THE STRUCTURAL COMPONENTS OF THIS
PLAN ARE IN COMPLIANCE WITH THE 2010
FLORIDA BUILDING CODE, WIND LOAD
COMPLIANCE AND ITS RESISTANCE TO
GRAVITY AND DESIGN PRESSURES
c�
0�
q r U M
LEI PLl z W
q
0_
- > Z,—i W�
W> a0 ON
�WL,JZ � —4
W3 cU
W 0 1/ 1 [3 ,W-12 (U
P:a Z Y >U I`
Q
q W LJW 00
N z U J
=NC� g0 M
JLd00�}v
(L Lj ZO—) �
Ne
r-I L7 U w
I=— W LL
LLJ
n
Y
V)
z W
W
O Z
Y 0
Z
w
U Q 00
_ W 000
N
04
LLJ 'n
o w
REVISION I DATE
to
w
N
En
z
W J
�w
QZ
O 0 Cy_
QM
L' J
00
O V)
Z
O
x
U
z
DATE 10-11-13
BY JCK
SHEET NUMBER
S-1
OCi 1 1 �Z�j=