HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE ONLY: LY: DATE FILED:12.1n t1 PLAN REVIEW FEE: RECEIPT NO.: 'A 1653 PERMIT NUMBER: l y O6 CONCURRENCY FEE: 10 3 58 RECEIPT NO.: CERT: CAP. NO.: ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 &Cq� 772-462-1553 11% APPLICATION for BUILDING PERMIT ®V1161 CERTIFICATE of CAPACITY/ZONING COMPLIANCE PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: p l nP, `TY..Q o- D t o 2. PROJECT NAME: SITE PLAN NAME: 3. PROPERTY TAX ID #: 31� 2 — %� 2 — d l —I I -- C7o o 0 nn 4. LEGAL DESCRIPTION (attach extra sheets if necessary): E5S+ 4cQ 5. PLAT BOOK 6. PAGE NO. 7. BLOCK NO. 8. LOT NO. �j g 9. PARCEL SIZE (ACRES/SQ FT.): LOT DIMENSIONS: 10. COMPLETE DESCRIPTION OF CONSTRUCTION PROJECT OR WORK ACTIVITY: Cht nes dNwQ i � C'e rn e aca -1 Orl 11. SETBACKS (ACTUAL) FRONT: BACK: RIGHT SIDE: LEFT SIDE: 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) [ ] NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ ] INTERIOR RENOVATION [ ] RESIDENTIAL [ ] COMMERCIAL [ ] INDUSTRIAL [ ] OTHER (SPECIFY) 13. DESCRIPTION OF PROPOSED USE: 14. SQ. FT OF CONSTRUCTION: 21 L{2 1' 15. SF. FT 1st FLOOR: 16. VALUE OF CONSTRUCTION: $601 2('0l .213 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application. SLCCDV Form No.: 001-02 UPDATED 6/25/09 1 i ,r" . . OWNER INFORMATION NAME: lvloyyla C -H •--- ADDRESS: 51 U ?- 1 YlP —Dr-le.- I �) ( • Q CITY: _ l'D' �' • � G.ru STATE: f - ZIP: �qy 2- PHONE (DAYTIME): U Email: IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: PHONE (DAYTIME). �) STATE: ZIP: CONTRACTOR INFORMATION /� ST. of FL REG.CERT #: ( ', C C, D I(t 2J ��D ST. LUCIE COUNTY CERT #: BUSINESS NAME: M.O.�`���-i QUALIFIERS NAME: J 0&6 P 1 �-• "'n e.e4 S ADDRESS: ►a . N--'d P'(.,ws 64- CITY: FT lxt'ter ck c f STATE: n �FA ZIP: 33311 PHONE (DAYTIME): t 1 A -JU1 - �i-- C.a FAX NO. "lr,( -1to 1 - kbb" Email: -j1 &-/YIoSS,e PYa A ARCHIT/ENGMER: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): (__) BONDING COMPANY: ADDRESS: CITY: MORTGAGE LENDER: ADDRESS: CITY: STATE: ZIP: STATE: ZIP: IMPORTANT NOTICE: When a ,permit is issued and it is not picked up within 60 days after notification it will be voided and returned to you by mail. ,r AWL - -- CERTIFICATION: This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, FENCES, ETC., not otherwise included with this building permit application. St. Lucie County makes no representation that its granting of a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Homeowner Association rules, bylaws or any covenants that may restrict or prohibit such structure. Please consult with your Homeowner's Association and review your deed for any restrictions which may apply. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOBSITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT: AS A CONDITION OF ISSUANCE OF THIS PERMIT, YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. STATE OF FLORIDA COUNTY OF i-, I a l ci The foregoing instrument was acknowledged before me this L2) day of 20_L�L SIGNATURE OF FLORID r Y OF�i�,L)c) r-C'I the foregoing instrument was acknowledged before me this day of L —OL , 20_1%�, by VA l,- Mt t1i S who is personally known or, ,aha��s produced who is personally known V or has produced n nnday( QA U �' �sidentification. tat44iil �j entification. Sign re of Not KRISTY L. CONTRERAS Signatur o 9 ��� °jam 9�; ., otpRY Assoc NOTARY PUBLIC * • N I35 �a Commission No.� Z% STATE OF FLORIDA Commission No. sgo: iFF08980�Seal�o` Comm# EE135409 s • � o sanded 1ht� i�.• O �, •S�NCE19Expires 10/3/2015 r/0 ....IISiA!���^�� NOTE: TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIGE�iet110'APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION. OWNER BUILDER AFFIDAVIT WILL BE REQUIRED FOR ALL OWNER/BUILDER APPLICANTS. For specific instructions see appropriate permit checklist. OFFICE USE ONLT SECTION 01 TOWNSHIP '� S RANGE L MAP NO. ZONING LAND USE J LOT CVG % TAZ NO. CONST TYPE OCCUP TYPE MAX OCCUP : # OF FLRS . WATER, ........_ .. - - SEWER SPRINKLERS.. STORMWATER - . LOT OF REC LOT OF REC LOT.SPLIT . LOT SPLIT 0*rV 111990 A&er 111990 REQUIRED APPROVED PORT HABTFABLE RADON DE �O AREA, FEE N) RARY PUBLIC BLD PUBIC.BLD ACT [FEE IMPACTFEE IMPACT 'CORRECTION FEEGENERAL.00L ROAD . CREDIT eACT FEEFir IlOACT FIRE/EMS DRIVEWAY Y N DRIVEWAY AeACT REQUIRED FEE FEE :SPECIFY MECHAMC ROOF NON -CONFORMING SUBS ELECTRIC. GAS LOT OF RECORD REQUIRED PLUN KING FEES DATE SENT TO ADDRESSING: / I REVIEWS FRONT ZONING COUNTER.. REVIEW =i -PERMPT FEE PARKS IMPACT FEE Y N LAW ENF IMPACT - : FIDE-. SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE REVIEW REVIEW . REVIEW. REVIEW REVIEW ..... '. -:PLANNING & DEVELOPMENT SERVICES'DEPARTMENT BUILDING & CODE REGULATIONS DIVISION - BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County. Contractor -Certification Number: I State of Florida.Certifcation Number tn•apr►imble): n have, agreed to: be the (Company: Name/l.ndividual:Name) ��a-rrC i sub -contractor for Moss -SS oC,6 a (Type -of Trade)' (Primary Contractor) for the project•.iocated at �L�p �•l �� lre� L ' (Project Street Addressor Property Tax 1D 0) -_ It is understood that, -if there, is any change of status -regarding our, participation -With the above mentioned project,.) will -immediately advise the Building and Zoning Department- orSt..Lucie County by personally -filing a Change of Contractor notice..(Form;-:SLCCDV . No: 004-00)... BUSINEWQUALIFIER (Name of.the Individual shown on the Contractor's License) O GINAL Si.GNATURES ARE REQUIRED. SIGNATURE' PRINT NAME DATE ,.Oo Business Name:. �11L,� qrr �%c t_tr� t_4LD�/ia�-.�' Address: S%I . i�w .. MQv[.ati h�tt (�i #f G3 city/State/ -POC 4 & i' uc ALL. �f:- 341 !. Phone:. 172 •?(— 74'7,f email: %I1! s FGC. . C. .OFFICE USE -ONLY: PERMIT # ISSUE DATE ...,PLANNING do DEVELOPMENT SER.V`I•f`GS D PARTMCN'r BUILDING & CODE REGULAT1UNS D1V'[SION . BUILDING PERMIT SUB-CONTRACI'Oli AGREEMENT St. .Lucie,Courity;ContraclorCcriilicatiop Number: State;of.rtori'da;Q&tifieation:l1U1.1iher tlrapplwablue C �;�_�� 3_S • ._� d• in" have; angl eed to -be the (6irioany Namdlndividual N e) pAn ` ; .¢ sub -contractor for (Type of>rade}� (Primary Contractor) for:the R.r©jeet'located at p r+n «- (Project Street Address or Property "fax In 0) It is undersEoq.d; ihai. if there.is' any change of status regarding our participation:,With'the . above tYientnoned pto�eej;.1*will immediately advise the Buildinga id Zoning Department of St. Lucie; County. by personally fling a Change of Contractor notice: (Form: SLCCDV BUSINESS' QUALIFIER' (Name of the Individual shotim,on t6e,C:ontracior's License) I?.tOINrII .S:II NATURES ARE'REQUIRED TE SIGNATURE:: '- � I �{ PRINT NAME D'�' Business,lTame:' �1 Address'�� ti < . r, City/State/Zip: Q (�', ►Jew, Phone• �Gi —F3S e nip. PERMITA ISSUE DATE I 1�. L1J1�1. L-7 PLANNING & DEVELOPMENT SERVICES DEPARTMENT BUILDING & CODE REGULATIONS DIVISION BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: State of Florida Certification Number (tfapplicable):� 49g�op , LA-6— have agreed to be the (Company Name/Individual Name) tp�(WAtL-A USOLAW sub -contractor for �_40955 (Type of Trade) (Primary Contractor) for the project located at 51 1 (Project Street Address or Property Tax ID #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: sLCCDv No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ORIGINAL SIGNATURES ARE REQUIRED 7:772� SIGNATURE Business Name: Address: a-� \,<© L9tict 317:7 z0!4 PRINT NAME DATE i L- City/State/Zip: , r-T— ?;"s74 Phone: email: MW(:L OFFICE USE ONLY: PERMIT # ISSUE DATE t- PLANNING & DEVELOPMENT'SERVICES DEPARTMENT ' BUILDING & CODE REGULATIONS IDIVISION BUILDING. PERMYr. ' ► SUB -CONTRACTOR AGREEME11tT' ,. St. Lucie County Contractor Certification Number: " State of Florida 'Cartification Number Ofappiicable): A Q L have agreed to be:'the. (Company, NameZIiidividu ame) A0_ sub -contractor for (Type of rade) (Prim Contractor.) for the project located' -at ►� (Project 1D Street Address or Property Tax` #, It is understood; that; if there is any change of status regarding our participation with the above mentioned;project;Twill immediately advise the BuildingnandZouing.Departin. of St. Lucie County: bypersonaBy filing a Change of Contractor nofice `( or ii `SliGCDv No. 0.04=00): Page 1 of 1 Julieth Lopez From: Julieth Lopez Sent: Wednesday ':Mar6 26, ;201'4 2:48 PM To: FranKYoung;;Michelle@acadvantageinb.com; dj.bellwether@grnail:com;.. sbuday@meeksp'lpmbing.com Cc: Julieth Lopez ' Subject: Fego- Fort Pierce>':.', Team, You have been award'ed'a :change order for the.Fego residence 5116 Pinetree Drive. Fort Pierce FI, 34982 �anir�l Ch 0('. O'thar+4�rin`• , ,a Electrical Sub - Bellwether Please send the appropriate application sign and notarized. Thank you, Julieth Lopez . Permit Expeditor { Mots.A. Associates o (954) 769-82261 m (786) 663=0935 1 f (954) 769-800.1 2101 N. Andrews Ave., Suite 300, Fort Lauderdale; FL 33311 Property Appraiser - St.Lucie"Couny,''Fti"'': http://www.g?'^:org%paslc/prc.asp?prclid=340260201710000 PROPERTY RECORD CARD Thomas H'Fego Record: 4 of"1;' •..:- <<Prev Next» Spec.Assmnt Taxes;" • Exemptions: ' Permits Home Print. Property Identification:... ;; ;.'. ,'.?i;::: ;;. ' ' ;.} • : Site Address:.Ec 5116 PINE TREE DR ,:' ParcellD: 3462-602-017140164 a Sec/Town/Range: 02.36$.40E : Account#: 36553 ! .C6 c Map ID: 34%02S • Use Type: SF. Res Zoning: RS=3 City/Cnty: Saint Lucie County Ownership and Mailing .'' ;'.;' Legal Description Owner: :_r s:,Thoitras`H;Fego'.' ; INDIAN RIVER ESTATES'UNIT,.9.=;BLIZ5;LOTS 8, 9 AND 10 (MAP 34/02S) Address: - " 5116 Rine Tree _Dr, (OR 1632-379) Fort Pierce FL 34982 Sales Information Assessment 2013 Total.1-and-arid Building Date. Price" Code Deed" Book/Page 2013.Final: 149200 Land)aIU6 ` 33700,Acres-:1.36 12/16/2002 32000•-'•;" `.. 00. _:: 1632 / 0379 Assessed: 149200 "Building',valde: 115500 7/1/1980 5000., 01 ' CV 0341 / 1430 Ag.Credit: " 0 Firh4tied.Area: 2345 SgFt 4/1/1973 0214/0223 Exempt: 50000 ' Taxable: 99200 Taxes:, 2190.44 BUILDING INFORMATION 14 tiWJ. r �r • m . s - tt .OtMri•.l .10 .� Exterior Features. - View: RoofCover: FS - Fibrglss Shg RoofStruct- HP - Hip ExtType:. HB HB'-' Yea[Biti. 2006 Frame: Grade: 6= B EtiYr.Blt: 2006 PiimeVl�all � ' BS - CB Stucco StoryHght: 0010 Story No'.Unw, 1 SecWall Interior Features - BedRooms: -3• Electric: MX- MAXIMUM PrmintlNall: DW - Drywall FullBath: " 2 HeatType: FHA- FrcdHotAir AvgHt/Fl: ' 1/213ath: 0.. HeatFuel:. ELEC - Electric Phn,Flors: CU - Carpet %A/C: 100 ,` %Heated: 100 %Sprinkled-., 0 Special Features and Yaed'iteris'; Land Information Type Y/S Qty.: Units•; "Qual. Cond. YrBlt. No. Use Type Type•' '' Measure Depth DWC - Driv-Concret Y, r: 1 200 AV. AV 2006 1 0100-SF Res BC=Front Ft 198 300 FNW6 -.WOOD FEN6' Y `".. 1 60, AV AV 2006 THIS INFORMATION,IS,BELIEVED TO'BE CORRECT AT THIS TIME BUT rr IS SUBJECT TO CHANGEAND'-IS:NOT WARRANTED. 1 of 1 2/17/2014 1:31 PM JOSEPH E. SMITH, OF THE CIRCUIT COURT - S: IE COUNTY r FILE # 3924373 �13W 3603 PAGE 1297 Record_ -pit /2014 at 11:16 3 J.. AFTER RECORDINGR AVRN TO: Moss and Associates, LLC CIO: Chris Krause 2101 N. Andrews Avenue, Ste 300 Wilton Manors, Florida 33311 PEMUT Nusmt:R: NOTICE OF CO%1\I EN(-F;N! Gti°T The undersigned hereby given notice that improvement will be made to certain real property. and in accordance with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. 01 . 1. DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO NUMBER: 3VP 2 -il(O 2--00/- 0 B - 0 SUBDIN'ISION BLOCK TRACE LOT BLDG UNIT . A - %P2.GENERALDESCRIPTIOYOFIAiPRO�'EMENT: t�GYh011iiOhl �I�d �R�Vfw101t�G QyIA?!tl )jF 3.OWNF,R INFORNIATION: a. Name b. Address �G r��P �C�� V!q 2 C. interest in property d. Name and address of fee Simple titleholder (if other than owner) 4. CONTR.ACfOR'S NAME, ADDRESS AND PHONE NUMBER: Moss andAssoclates, LLC 2101 North Andrews Avenue, STE #300 Wilton Manors, FL 33311 9544244079 5. SURETY'S NAME, ADDRESS AND PHONE. NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Fcrsrnrs within the State of Florida designated by Owner upon w•htnn notices or other documents may be served as provided by Section 713.13 (1 I(a) T. Florida Statutes: NAME, .ADDRESS AND PHONE NUMBER: S. In addition to himself or herself, Owner designates the fill loving to receive a copy of the Lienor's Notice as provided in Section 713.13 0)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is I year from die date of recording unless a different date is sprsifted) 20_ Signature ror Owner's Authorized Officer/Director•/Partner/hInanger Print Name and Prm Ede Signatory's Title/Office M AP State of Florida County of uC The .f�o�rr� e•�going instrument was acknowledged before me this J�day of R-10 C U cr r h 20�_. By 1.0✓riPisi C-C-0, f) as nCy r. (Printed name of person sigh above) (T%pe ofauthority... c.g Owner, officer, trustee, attorney in fact) For O WZ-t'..`.S �$ ) (Name of party on behalfor whom it irument ivus executed) Personally Known_ or produced the following type of ID: p,` 1 y Ct �L3_ A l KEU Y 3cHU AIEZ NOTARY PUBLICBLIC (Printed N, me ofNetary Public) (Signaiurc of any Public) STATE OF FLORIDA Comm# DD997823 Undcr penalties of perjury, I declare that I have read the foregoing mid that die facts in it are Due to the �n"EkplE9iliN2014 helief(secdon 92.52?, Florida Statutes). Signature(s) of Owner(s) or Owner(s)' :Authorized O(ficer/Direclor/Partner/Alauager who signed above: By: - ",�TVri,.n,a By Z a /h %4S je�-e glL, O Rn.OL'JQ:wi]IRwvdingl (Signature) (Printed Name) STATE OF FLOCERTIFYTEttg `Sr nQGllIDA 4irr.T Date- ki Exhibit F REMEDIATION PROTOCOL I. Scope of Work The remediation work to be performed in a KPT Property is described generally below. In conducting the remediation work and in resolving any disputes pursuant to the dispute resolution process in the Settlement Agreement_(reprinted in Paragraph V below), the KPT Property Owner and Lead Contractor or Other Assigned Contractor agree that the objective of the remediation work is,to remove on a cost effective basis all drywall; problem drywall -related: odors, and contamination, including, but not limited to, corrosion, tarnishing and pitting ("Contamination"); and to leave the KPT Property with the same construction quality and finishes, including remediating any damage to such quality and finishes that was caused: by the drywall, as existed prior to the start of the remediation work. A. Drywall Removal. Removing and replacing all drywall in the home, including ceilings, with the exception of the following materials unless removal of such materials is required in order to complete the Remediation Work:pursuant to this Scope of Work:. 1. Type X fire rated board 2. Thicknesses other than'/2" 3. Moisture Resistant Drywall "Green board" COPY 4. Sag Resistant Gypsum Board 5. Tile Backer Board B. Electrical Wiring. Remove and replace all electrical wiring (including low - voltage wiring), switches, service panels, :circuit breakers, receptacles, and all Contaminated circuit boards. C. Fire Safety and Home Security Equipment. Remove and replace all fire safety equipment, including security alarms, intercoms, smoke detectors, fire suppression sprinkler systems, and carbon monoxide alarms.. D. Copper gas lines. Replace. all copper gas lines and fittings. All other gas.1iries and fittings will be inspected. for Contamination and.replaced if Contamination is found. E. Fixtures. Remove, store and reinstall the following :to the extent such fixtures interfere with the removal of the drywall as described in Paragraph A. Otherwise, such 'f xtures will remain in place with suitable protection. In the event of any Contamination: to such fixtures caused by the possible problem drywall or damage V from the drywall removal and. replacement, such fixtures will be replaced.' 1. Hot water heaters 2. Cabinets 3. Countertops V 4. Doors 5. Moldings and trim as required to remove drywall as described in Paragraph A 6. Sinks 7. Toilets 8. Bathtubs, shower enclosures 9. Mirrors 10. Lighting fixtures `� 11. Ceiling fans IL 12. Plumbing fixtures 13. Exhaust Grills and Diffusers 14. Marble, granite and other natural -stone pieces 15. Doors.and:attached door hardware F. Dust Control and Removal. Remove the drywall using methods for dust control routinely used in drywall renovation projects. 1. These control methods typically include installation of drop cloths and walk -off mats, negative pressurization of work area with exhaust fans, and cleanup of dust and: debris. 2. Following :the removal of all drywall as described in Paragraph A, sweep all bulk debris and remove from site. 3. Following the sweeping, vacuum all surfaces including wall cavities using vacuums equipped with drywall bags and/or; where appropriate or ' In the event that equipment, appliances or fixtures need replacement, the replacement will be, with new equipment, appliances or fixtures. and not with reconditioned ones. 60266950.2:DOCX 2 necessary, HEPA (high efficiericy particulate air) filters; to remove drywall dust. 4. Damp wipe all surfaces with water. 5. As a final. step, use Odorox® hydroxyl generators to resolve any residual indoor air problems. G.. HVAC. The following HVAC repairs. will be performed by a.manufacturer- qualified firm, but if such firm is not available, by a licensed HVAC technician. 1. Remove and replace all air handler units, including the coils. 2. Remove and replace all line sets. 3. Replace thermostats in affected areas and, control boards in affected air handling units; and'otherwise clean and/or: replace as needed the air handler. 4. Replace over limit controls on electric heating coils in affected units. 5. Remove and -replace the flexible duct work: 6. Inspect and clean the metal duct work. 7. Remove and replace all other damaged HVAC system components.. H: Insulation. Remove and replace porous insulation and repair or replace as necessary non -porous insulation in direct contact with the drywall to be removed. 1. . Porous Insulation a) Fiber glass insulation . b) Cellulose insulation - ILE, c) Open cell foam insulation 2. Non -Porous Insulation a) Closed cell foam insulation b) Reflective insulation I. Carpet and Flooring. Remove and replace all carpet, carpet padding, laminate flooring and laminate padding. All other flooring will remain in place and be protected during the remediation work. 60266950.2:DOCX 3 I J. Plumbing. Remove and replace all affected plumbing, components that either show discoloring or pitting on exposed components such as faucets, and handles. 2. All other piping, fittings and components to be inspected, cleaned of any Contamination, and; if functionally unaffected, remain in place. K. Appliances. Appliances shall mean refrigerators, freezers, dishwashers, washers, dryers; garbage disposals, wine coolers, ice machines., microwaves, cooktops, ovens, ranges and warming drawers. 1. For KPT Properties that are less than or equal to 3,500 square feet "under air," as determined by the Lead Contractor or Other Approved Contractor ("Under Air Area") and as set forth in the attached Sample Contractor- KPT Property Owner. Agreement, remove and replace refrigerators and freezers located in the kitchen, wine coolers, ice machines, microwaves, cooktops and ovens. All other Appliances, including, secondary and auxiliary refrigerators and freezers, shall be removed and replaced: where the performance or appearance is compromised, for example, where. there is Contamination. 2. For KPT Properties that have an Under Air Area greater than 3,500 square feet, all Appliances shall be removed and replaced where the performance or appearance is compromised.. T . Items not Replaced. Building materials, building systems, fixtures and Appliances that will be removed and reinstalled shall'be placed in storage. Building materials, building Systems, fixtures and Appliances that will be retained in place will be protected during the remediation work. Any Building materials, building systems; fixtures or Appliances that are retained, but damaged during the remediation work, will be restored to the condition that existed prior to the start of the remediation work, and where necessary, replaced. M. Finishing. Finish and paint all new drywall using a primer arid. two coats of paint of the same color and finish (e.g. flat, eggshell, satin, semi -gloss, and glossy). N.. Final Cleaning. Clean the Home to pre -repair condition, which will be documented prior to the start of the remediation work. O. Documentation and Preservation. In the course of remediation, the contractor willfully document the remediation work using photographic and other documentation .methods, including but not limited to identification of the manufacturer and condition of the possible problem drywall on:a room by room, wall by wall and board by board basis. At the option and sole expense of:KPT, all possible problem drywall and fixtures, wiring, fire safety equipment, plumbing, wiring, carpets, and appliances or other items removed from the home will be maintained for scientific analysis. 60266950.2:I)OCX P. Government Agency Access. Relevant government agencies, including but not limited to the Consumer Product Safety Commission, will be allowed to observe thexemediation work and given access to the documentation materials and items described in Paragraph I (0). II. Form of Agreement between Contractor and KPT Property Owner The agreement by which the Lead Contractor, or Other Approved Contractor, will perform the remediation work in the KPT Property shall take the form of the attached Sample Agreement between Contractor and KPT Property Owner. III. Contractor and Environmental Certification A. After completion of the Drywall Removal and Dust Control and Removal pursuant to Paragraphs I (A) and (F) above, the Lead:Contractoi or Other Approved Contractor will provide the Settlement Administrator and KPT Property Owner with a Contractor Certification substantially. in the form of Exhibit 6 to the ,attached Sample Agreement between Contractor and KPT Property Owner. B. After receiving the Contractor Certification, the Settlement Administrator will assign an environmental inspector to certify the absence in the. KPT Property of any remaining problem drywall -associated odors and contamination, including, but. not limited to, corrosion; tarnishing, and pitting. I . If the environmental inspector concludes the -KPT Property is free of any and all KPT Chinese Drywall and Non KPT Chinese Drywall ("Problem Drywall") associated odors and contamination, the environmental inspector will provide an Environmental Certificate (in the form attached as Exhibit B to the Settlement Agreement) to the Settlement Administrator and the KPT Property Owner certifying that the home is -free of any and all Problem Drywall -associated odors and contamination. 2. If the Environmental Inspector concludes the KPT Property is not free of any and all Problem -Drywall associated odors and contamination, the Lead Contractor, or Other Approved Contractor, will continue to remediate any issues.identified by the environmental inspector until such time that the environmental inspector concludes the KPT Property is free of any and all Problem -Drywall associated odors and contamination, in which case the environmental inspector will.provide the Environmental Certificate as specified in the above subparagraph II (B) (1). C. The KPT Property Owner and/or his counsel, upon sufficient notice, shall have the right to be present, but not to interfere with, any environmental inspection by the: environmental inspector,, and to videotape, or otherwise make a record of, such inspection. The costs of the environmental inspector will be paid by the Remediation Fund. lot 60266950.2:I)0CX 5 IV. Warranty A. The Lead Contractor, or Other Approved Contractor, will provide the KPT Property Owner with a warranty substantially in the form of the warranty provided for in the attached Sample Agreement between Contractor and KPT Property Owner. B. If Lead Contractor, or Other:Approved Contractor, does not perform, or is unable to perform, work required by the warranty described in subparagraph IV (A), the Remediation Fund will assume responsibility for procuring substitute performance under the warranty ("Guaranty of Warranty"). C. The Lead Contractor, or Other Approved Contractor, is responsible for satisfaction of all. material and labor liens placed on the KPT Property in connection with the remediation work. V. Dispute Resolution (reprinted from Sections 4.5.1.2.1 and 4.5.1.2.2 of the Settlement Agreement) A. In the event that a dispute arises between a KPT Property Owner and the Lead Contractor or Other Approved Contractor over the Remediation Protocol for the individual KPT Property, such dispute shall be submitted to the Special Master who will resolve the dispute. The parties shall cooperate with the Special Master to resolve any disputes expeditiously and avoid, to the maximum extent possible, any delay in the remediation': B. Any expenses associated with a dispute between a KPT Property Owner and the Lead. Contractor or Other -Approved Contractor ("Mediation Expenses') -as regards the Remediation Protocol, including progress and quality, and any warranties provided by the Contractor, will be jointly shared by the Knauf Defendants and the KPT Property Owner. In the event that disputes asserted by a Party., either singly or in combination, unreasonably delay the remediation or are asserted in bad faith, the Special Master may in his discretion direct that the Mediation Expenses incurred in resolving any such bad faith. disputes asserted by that Party will be paid by same, regardless of whether the Special Master resolves the dispute in that Party's favor; otherwise, expenses :will be shared equally by the Parties to the dispute. VI. Ombudsmen The KPT Property Owner shall be able to consult with an Ombudsman, as that term is defined in Section 1.42 of the Settlement Agreement, regarding matters relating to the remediation process, including, but not limited to, the actual remediation work, and, in the event that a dispute arises during the dispute resolution process described in Paragraph V above. 60266950.2:DOCX 6 CORM 4b5-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Majestic Homes Builder Name: Street: 5116 Pinetree Drive Permit Office: St. Lucie County City, State, Zip: Ft. Pierce , FL , Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1878.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 1628.00 ft2 b. Frame - Wood, Exterior R=11.0 250.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2275.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2275.00 ft2 6. Conditioned floor area above grade (ft2) 2275 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A 11. Ducts R= ft2 R ft2 7. Windows(275.5 sqft.) Description Area a. Sup: Attic, Ret: RoomslnBlockl, AH: Garage 6 455 a. U-Factor: Sgl, U=0.29 275.50 ft2 SHGC: SHGC=0.30 b, U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 59.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 59.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 0.935 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2275.0 sgft.) Insulation Area EF: 0.990 a. Slab -On -Grade Edge Insulation R=0.0 2275.00 ft2 b. Conservation features b. NIA R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.121 Total Proposed Modified Loads: 35.01 PASS Total Standard Reference Loads: 44.53 I hereby certify that the plans and sp ff0c"ab s c eyed by Review of the plans and Oki'SiE ST.g?� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY; �����i/Q�" DATE: Q ��`s Before construction is completed this, building will be inspected for compliance with Section 553.908 X. I hereby certify that this building, as de ned, ' i compliance Florida Statutes. eOD with the Florida Energy C,bde. WE'D OWNER/AGENT: �D BUILDING OFFICIAL: DATE: DATE: Compliance ro qu res completion of a Florida Air Barrier and Insulation Inspection Checklist `4 tat• ' c 6/11201412:23 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 79 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows*" Description a. U-Factor: Sgl, U=0.29 SHGC_ SHGC=0.30 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 5116 Pinetree Drive, Ft. Pierce, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=4.0 1628.00 ft2 b. Frame - Wood, Exterior R=11.0 250.00 ft2 1 c. N/A R= ft2 3 d. N/A R= ft2 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=30.0 2275.00 ft2 2275 b. N/A R= ft2 c. N/A R= ft2 Area 11. Ducts R ft2 275.50 ft2 a. Sup: Attic, Ret: RoomsinBlockl, AH: Garage 6 455 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 59.0 SEER:14.00 ft2 0.935 ft. 0.300 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2275.00 ft2 b. N/A R= ft2 c. N/A R= ft2 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: kBtu/hr Efficiency 59.0 HSPF:9.00 Cap: 50 gallons EF: 0,99 CF, Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. *"'Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. t � EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software PROJECT Title: Majestic Homes Bedrooms: 3 Address Type: Street Address Building Type: FLProp2010 Conditioned Area: 2275 Lot # Block/SubDivision: Owner. Total Stories: 1 Worst Case: No PlatBook: # of Units: 1 Rotate Angle: 0 Street: 5116 Pinetree Drive Builder Name: Permit Office: St. Lucie County Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Ft. Pierce. FL, Family Type: Single-family New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp J Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 2275 22750 SPACES FRoomslnBlock1 Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 2275 22750 Yes 3 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio RoomslnBlockl 226 ft 0 2275 ftZ 0 0 1 ROOF r:v Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2464 ftZ 0 ftZ Medium 0.96 No 0.9 No 0 22.6 ATTIC F Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2275 ftZ N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) RoomslnBlockl 30 2275 ftZ O.i 1 Wood 6/1/2014 12:23 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below # Ornt' 10 Wall Type1 N Exterior , Concrete Block - Int Insl1oomsInBIoc 4 33 8 264 ft2 0 0.75 0 ' 2 S Exterior Concrete Block - Int InsGIoomsInBIoc 4 50 10 500 ft2 0 0.75 0 3 E Exterior Concrete Block - Int lnsMoomslnBloc 4 44 8 352 ft2 0 0.75 0 4 W Exterior Concrete Block - Int Ins6IoomslnBloc 4 64 8 512 ft2 0 0.75 0 5 E Exterior Frame - Wood RoomslnBloc 11 20 8 160 ft2 0.23 0.75 0 6 N Exterior Frame - Wood RoomslnBloc 11 9 10 90 ft2 0.23 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood RoomslnBloc None 0.460000 3 7 21 ft2 2 E Wood RoomslnBloc None 0.460000 3 7 21 ft2 3 E Wood RoomslnBloc None 0.460000 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Tinted) Yes 0.29 0.3 N 4 ft2 1 ft 0 in Oft 0 in HERS 2006 None 2 N 1 Metal Single (Tinted) Yes 0.29 0.3 N 18 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 3 E 3 Metal Single (Tinted) Yes 0.29 0.3 N 48 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 4 E 3 Metal Single (Tinted) Yes 0.29 0.3 N 6 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 5 E 3 Metal. Single (Tinted) Yes 0.29 0.3 N 12 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 6 E 3 Metal Single (Tinted) Yes 0.29 0.3 N 11.5 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 7 E 3 Metal Single (Tinted) Yes 0.29 0.3 N 5 ft2 1 It 0 in 0 ft 0 in HERS 2006 None 8 W 4 Metal Single (Tinted) Yes 0.29 0.3 N 45 ft2 Jrft 0 in 0 It 0 in HERS 2006 None 9 W 4 Metal Single (Tinted) Yes 0.29 0.3 N 18 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 10 W 4 Metal Single (Tinted) Yes 0.29 0.3 N 42 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 11 S 2 Metal Single (Tinted) Yes 0.29 0.3 N 24 ft2 1 ft 0 in 0 ft 0 in HERS 2006 None 12 S 2 Metal Single (Tinted) Yes 0.29 0.3 N 42 ft2 1 It 0 in 0 ft 0 in HERS 2006 None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 It 8 ft 1 INFILTRATION # Scope . Method. SLA CFM 50 ELA EgLA ACH ACH 50 1 BySpaces Proposed SLA 0.000360 2148.2 117.93 221.79 0.2628 5.6657 � `, 'gig � • 6/1/201412:23 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 9 59 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER` 14 59 kBtu/hr 1770 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.99 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V — Supply — — Return — Air Percent HVAC # # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool 1 Attic 6 455 ftz RoomslnBloc 113.75 DSE=0.88 Garage 0.0 cfm 0.00 % 0.00 0.60 1 1 TEMPERATURES Programabl[eXjThermostat: Ceiling Fans: ]Y [[XX]] Heat ng [X] Jan [X] Feb [X] Mact r Apr Jul' May Jun rxi X Aug [X] N Sep [?� LXI Oct Nov rxi Nov Dec XX Dec Venting [X] Jan [X] Feb [[XX]] Mar Jun Jul [ Aug [X] Sep l Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80, 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/1/201412:23 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 �ORM'405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method 'ADDRESS: 5116 Pinetree Drive PERMIT #: Ft. Pierce, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENTS) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more'speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special - equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 6/1/201412:23 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 Project Slummary: yob F Date 7; 14 Entire HOUSe.: .pherT. Rizzoi A�>itI t g ;i t w. e • J For: 5e Pine Tree.Dc, Fort pierce; fl r QeqnAfiformation Weather. Vero Beach, FL, US ti Winter Design Conditions Summer Design Conditions Outside dt%' 43 OF Outside:db •90 °F Inside db 70.' °F Inside.db.' .75 OF Design TD ;27', OF Design TD 15 'OF Daily rangge L .. Relative humidity '' S0 Moisture.difference,,'•;,. .61 gr/lb Heating Summary Sensible Cooling'E.cquipment Load'Sizing Structure : .23553 Btuh Structure,. : ; 37902 Btuh: Ducts 5127 Btuh Ducts 8877 Btuh Central -vent _(0 cfm) . 0 Btuh Central-vent{0 cfrrt) '0. 'Btuh' Humidification. • 0:-,Btuh Blower.0 ;Btuh Piping 0 Btuh. Equipmentload �26679 `Btuh Use manufactarei's data n . Rate/swing multiplier 0.95 ' r Infiltration Equipment sensible load` 44440 Btuh Method Simplified Latent.Cooling fqulpmentLoad.Sizing Construction. quality Semi -tight Fireplaces. 0 Structure 3270 Btuh. Ducts. 2637 Btuh - Neating = ..Cooling Central.vent (0'cfm) '0 Btuh Area.(ftZ) "2220 . �2220 Equipment latent: load `, 58.07 .Btuh ' Volume (ft�) 24415 24415 . Air changes/hour- 0:22 0.11 Equipment total1load 50247 Btuh. Equiv.-AVF.(cfm) �90 45. Req; total capacityat0.70'.SHR - 5.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make.. Ruud•. Trade Trade RUUD 14AJM$ERIES Model- Cond. 14AJM6. AHRI ref Coil RHLL-HM$1J24.4RGSL H-6024 AHREfficiency 100 EFF Ellice cy 3799471 13.0 EER, `16'SEER' '- ' Heating input 8.0 , kW' Sensible cooling. ; , . 37800 Btuh.. :Heating output 27244 Btuh Latent cooling ; 16200i'Btuh Temperature rise .14 OF Total cooling 54000 'Btuli _ Actual airflow' 1800 cfrm . Actual airflow 1,800 •cfm- Airflow#actor- 4 0;063 efm/Btuh Air flow 0-038. cfm/Btuh . . Static pressure 0 `im H2O Static.pressure 0 .in H2O Space•themlostat Load sensible heat ratio OM CaicUlations approved byACCA.to meet all -requirements::of. Manual. J 8th Ed 2ot4-Ma 8 1a-. '�" WtIgiIXSOf , jyghtSUlte�llniverse42012121.08RSU02908 a { H:W1yDoameOtsWeatloadsWlosslFegoNp: Calc=M18 FrontDaorfaces: N ' AHRI Certified R6fekepdq-Xqrnbpr:, 3799471"- Date: 3/28/2.014 . Product: Spllt.;Systioft�'A Cooled-Condensing Unit, Coll with B ower,.. . Outdoor UhitabddlNumber:, 14AJM56 Indoor-Unit-Mod6l'Niihibb.r,,RHLL-HM6024+RCSL-H*6024 v Manufacturer: RHEERSALIE ;S,CbMPANY, INC.; Trade/Brarid name: ATNERKING Series 'I Manufacturer responsible -for the, rating of this system combination is RHEEMS4LESCOMPANY, INC.: Rated as follows :In,.a'c6oidahc6VI - th,AHRI.Standbrd-210/240-2608 for . Unitary..41 - i�,Corfalti6hi I rig and Air -Source Heat Pump Equipment t and jds0b,*` ,�Jddt tc 'verification of rating accuracy by AHkf sO'6.ris6icid,16diapende'nt,.third party testing. is J� 5', " Cooling Capac ity iuhl ""'.:5406' v") j,��Vz'p M 11100 AiF �V, 'Ratingi(Ci R, @6 r x 'OSEP";f;o r V;, . . . . . . . . . . . . . . Y. .4 Ratings folloWer. 15y Urerate of previously published,6ta, Unless lirifi,°Q @ninklunlaryyeratei.- .1 -DISCLAIMER AHRI does not endorse the antees as to; ind'ai products) Certificate and makes representations,.warrantiesbrguaI sqmes no responsibility for, the product(s) listed on this Certificate. AARLoOiessly'd1scialms all liability for damages of any kind arising out oftheuseorpi6nmence. of the product(s), or the unauthorized al t alteration of data Ilsie Ii Certificate. Certified ratings are valid only for models and coqflgy!atiorii�liitii!:I'o.the ' directory. at w.ww.ahridirectory. org, TERMS AND CONDITIONS AM te shall only be used lndIv10qaI,.'p0rqpn0 This Certificate and Its ;ontents-:aWproprletary products.of.AHRL'ThisCertifica and `�bs�"Tih '00htentsQfthJs,t . ertifi�ate may not, In whole or in part, dreproduced-,top ssemi at' -confidential refereke'purpo, fi led, . o d, I" or otherwise utilized, in any form or mannerorbyanyme ns, e c 1pt.forl a 'ut6r! Andi I entered Into 6 comp�jek.di6bdqe, I reif re!�cei, AIR-CONDITIONING, HEATING,: .personal and confidintiA - CERTIFICATE VERIFICATIONREFRIGERATION INSTITUTE ,'. The information for the model cited this his certificate can be verified at www.ahrldirectory.org,,click on Werify'Cortifleate!4inis, niaha lilc heifer"' and enter the AHRI Certified §eferenice Numbeir and the date -on which the certificate was Issued,: r6fi6ate NQ:��whlch. Is listed at bottom right. which Is listed above, and the�Ce. ;G i30404887337 @2014 Air-Cofiditiohing,,Hooph$��,'�qd',Ro rigeration. Institute .. ...... Majestic Homes HVAC Load Calculations for 5116 Pinetree Drive Fort Pierce, Florida RHVACWAC o 9 E Prepared By: Residential Energy Calc's Sunday, June 01, 2014 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac Residential Light Commer%iaf HVAc Loatl_s Elite.5oftware Development, Inc. ResidentiahEnergy Calo's Majestic Homes Port Saint Lucie, FL 34983 Page 2 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 78 59% 50% 75 61 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:1... 1Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM CA ...1Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM CA ... \Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM Rhvac - Residential & Light Commercial "VAC Loads' Elite Software Development, Inc. Residential Energy C'alds Majestic Homes Port Saint Lucie FL 34983. Pa e 8 Detailed. Room Loads - Room 1 - Foyer (Average Load Procedure) ,•General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 6.0 ft. System Number: 1 Room Width: 5.5 ft. Zone Number: 1 Area:. _ 33.0 sq.ft. Supply Air: 73 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 13.3 AC/hr Volume: 330.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: 73 CFM Percent of Supply.: 1 % Runout Duct Size: 5 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 537 ft./min. Percent of Supply: 1 % Runout Air Velocity: 537 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.238 in.wg./100 ft. Actual Summer Infil.: 2 CFM E-Door-11 D 3 X 7 21 0.390 10.9 229 10.1 0 213 E-Door-11 D 3 X 7 21' 0.390 10.9 229 10.1 0 213 E -GIs-1A-cm-o shgc-0.75 100%S 6 1.270 35.6 213 34.8 0 209 UP-Ceil-16C-30 6 X 5.5 33 0.032 0.9 30 1.3 0 42 Floor-22A-ph 6 ft..Per. 6 1.358 38.0 228 0.0 0 0 Subtotals for Structure: 977 0 703 Infil.: Win.: 3.4, Sum.: 1.5 60 1.717 103 0.417 64 25 Ductwork: 365 327 AED Excursion: 255 Equipment_-------- —---------------- --------- — --------- ---------300- — ---300 Room Totals: 1,445 364 1,610 It - C:\ ...\Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM Rhvac Residential &Light Commercial HVAC Loads EI_6 Software Development, Inc.: FtesidentialEnergy Calc's _:.,-_ �. Majestic Homes' Port Saint Lucie, FL' 34983 ;• Pa e 9 Detailed Room Loads - Room'2 - Office (Average Load Procedure) General `° ' Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.5 ft. System Number: 1 Room Width: 10.0 ft. Zone Number: 1 Area: 125.0 sq.ft. Supply Air: 175 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 8.4 AC/hr Volume: 1,250.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 2 CFM Runout Air: 88 CFM Percent of Supply.: 1 % Runout Duct Size: 5 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 643 ft./min. Percent of Supply: 1 % Runout Air Velocity: 643 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.339 in.wg./100 ft. Actual Summer Infil.: 3 CFM Item" t tauArea° U fi`HtgrxSen�,�t�,gt��Lat Sen Desenpt�on h -Quanti Ualue ;HTM Loss 4, ..��HTM.1, tkGam ;, _ Gain E -Wall-13A-4ocs 12.5 X 8 70 0.143 4.0 280 2.2 0 153 E -GIs-1A-cb-o shgc-0.75 20%S 24 1.080 30.2 726 76.6 0 1,839 E -GIs-1A-cm-o shgc-0.75 83%S 6 1.270 35.6 213 44.5 0 267 U P-Ceil-1 6C-30 12.5 X 10 125 0.032 0.9 112 1.3 0 160 Floor-22A-ph 13 ft..Per.13 1_.358 38.0 494 0.0 0 0 Subtotals for Structure: 1,825 0 2,419 Infil.: Win.: 6.6, Sum.: 2.6 100 1.720 172 0.420 107 42 Ductwork: 676 784 AED Excursion: 609 E_quip_ment: 600 0 Room Totals: 2,673 707 3,854 C.\ ...\Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM Rhuac - Residential,& Light Commercial HVAC Loads Residential Energy,Calc's , , . Elite Software Development, Inc. Majestic Homes, ,Port Saint Lucie, FL 34983 _ 'Page 10 Detailed Room Loads - Room 3 - Master Bath (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 15.0 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 180.0 sq.ft. Supply Air: 127 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.3 AC/hr Volume: 1,440.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 3 CFM Runout Air: 63 CFM Percent of Supply.: 2 % Runout Duct Size: 5 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 464 ft./min. Percent of Supply: 1 % Runout Air Velocity: 464 ft./min. Actual Winter Infil.: 16 CFM Actual Loss: 0.178 in.wg./100 ft. Actual Summer Infil.: 7 CFM Item . Area U Htg , ;; Sen Clg Lat Sen Description Quantity Value , HTM Loss' HTM Gain ' Gain S -Wall-13A-flocs 15 X 8 93 0.143 4.0 372 2.2 0 203 E -Wall-13A-4ocs 12 X 8 96 0.143 4.0 384 2.2 0 210 N -Wall-13A-4ocs 4 X 8 32 0.143 4.0 128 2.2 0 70 S -Wall-13A-4ocs 4 X 8 32 0.143 4.0 128 2.2 0 70 S -GIs-1A-cb-o shgc-0.75 100%S 23 1.080 30.2 696 32.0 0 736 (2) S -GIs-1A-cm-o shgc-0.75 100%S 4 1.270 35.6 142 34.8 0 139 UP-Ceil-16C-30 15 X 12 180 0.032 0.9 161 1.3 0 230 Floor-22A-ph 35 ft..Per. 35 1.358 38.0 1,331 0.0 0 0 Subtotals for Structure: 3,342 0 1,658 Infil.: Win.: 15.6, Sum.: 7.2 280 1.721 482 0.425 299 119 Ductwork: 1,294 566 AED Excursion: 440 Etc uipment_ _ _ _ 600 0 Room Totals: 5,118 899 2,783 C:\ ...\Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM [Rh -vac - Residential & Light Commercial HVAC Loads Elite Software Development; Inc. ReSldential Energy Calc's Majestic Homes §&Saint Lucie FL 34983 Pa q 11 Detailed Room Loads - Room 4 - Walk In Closet (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 11.0 ft. System Number: 1 Room Width: 7.0 ft. Zone Number: 1 Area: 77.0 sq.ft. Supply Air: 39 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.8 AC/hr Volume: 616.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: 39 CFM Percent of Supply.: 1 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 446 ft./min. Percent of Supply: 1 % Runout Air Velocity: 446 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.225 in.wg./100 ft. Actual Summer Infil.: 1 CFM Item; Area -U- `' Htg Sen Clg Lat <; Sen Descri tion' Quantit Value ; HTM Loss . ' � HTM 'Gain Gain S -Wall-13A-4ocs 7 X 8 56 0.143 4.0 224 2.2 0 123 UP-Ceil-16C-30 11 X 7 77 0.032 0.9 69 1.3 0 99 Floor-22A-ph 7 ft.. Per. 7 1.358 38.0 266 0.0 0 0 Subtotals for Structure: 559 0 222 Infil.: Win.: 3.1, Sum.: 1.4 56 1.714 96 0.429 60 24 Ductwork: 222 174 AED Excursion: 135 Equipment: 300 300 Room Totals: 877 360 855 C:\ ...1Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM Rhvac Residential & Light Commercial HVAC Loads ;., .Elite Software Development, lnc.: Residential Energy Calc's, :. '. Majestic Homes'` 7. POrt'unt Lucie, FL.349$3 r ,Detailed Room Loads - Room 5 - Master Bedroom (Avera e• Load Procedure) Calculation Mode: Htg. & clg, Occurrences: 1 Room Length: 19.0 ft. System Number: 1 Room Width: 17.0 ft. Zone Number: 1 Area: 323.0 sq.ft. Supply Air: 328 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 6.1 AC/hr Volume: 8,230.0 cu.ft. Req. Vent. Cig: 0 CFM Number of Registers: 3 Actual Winter Vent.: 5 CFM Runout Air: 109 CFM Percent of Supply.: 1 % Runout Duct Size: 6 in. Actual Summer Vent.: 4 CFM Runout Air Velocity: 556 ft./min. Percent of Supply: 1 % Runout Air Velocity: 556 ft./min. Actual Winter Infil.: 23 CFM Actual Loss: 0.198 in.wg./100 ft. Actual Summer Infil.: 11 CFM " , x , Area �Y I- U ` Sens" Descri tion .>, ' k u � r a4.,:•k Quantit �eValue,� .HTM, ,;;Loss: _. H7M Gaairi! S -Wall-13A-4ocs 21 X 10 210 0.143 4.0 841 2.2 0 459 W -Wall-13A-4ocs 13 X 10 106 0.143 4.0 424 2.2 0 232 NW-Wall-I3A-flocs 7.5 'X 10 47 0.143 4.0 188 2.2 0 103 W -GIs-lA-cb-o shgc-0.75 100%S 24 1.080 30.2 726 32.0 0 768 NW-GIs-1A-cm-o shgc-0.75 0%S 28 1.270 35.6 996 71.0 0 1,987 UP-Ceil-16C-30 19 X 17 323 0.032 0.9 289 1.3 0 413 Floor-22A-ph 42 ft..Per. 42 1.358 38.0 1,597 0.0 0 0 Subtotals for Structure: 5,061 0 3,962 Infil.: Win.: 23.2, Sum.: 10.7 415 1.720 714 0.424 444 176 Ductwork: 1,954 1,465 AED Excursion: 1,138 People: 200 iat/per, 230 sen/per: 2 400 460 Equipment:___ 600 0 Room Totals: 7,729 1,444 7,201 C:1... 1Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM Rhvac - Residential & Light Commercial HVAC Loads. Elite. Software Development, Inca Residential Energy Calc's _ _ Majestic Homes ' ,Port Saint Lucie, FL 34983 Detailed Room Loads - Room 6 - Living (Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 20.0 ft. System Number: 1 Room Width: 18.0 ft. Zone Number: 1 Area: 360.0 sq.ft. Supply Air: 153 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 2.6 AC/hr Volume: 3,600.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 2 CFM Runout Air: 77 CFM Percent of Supply.: 1 % Runout Duct Size: 5 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 563 ft./min. Percent of Supply: 1 % Runout Air Velocity: 563 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.261 in.wg./100 ft. Actual Summer Infil.: 3 CFM Itema ',ra } Areafx,��r�, U„ f k;;. " Htg :.��;Sen 'p Clg.: List R Sen :. } j� r Descr ption "� IN, uanti RIM .....:. Q � 4Ualue . . .. HTM , ,.: Loss f M Gam ` Gain HT W -Wall-13A-4ocs 10 X 10 52 0.143 4.0 208 2.2 0 114 W -GIs-IA-cb-o shgc-0.75 100%S 48 1.080 30.2 1,452 32.0 0 1,536 UP-Ceil-16C-30 20 X 18 360 0.032 0.9 323 1.3 0 461 Floor-22A-ph 10 ft.. Per. 10 1.358 38.0 380 0.0 0 0 Subtotals for Structure: 2,363 0 2,111 Infil.: Win.: 5.6, Sum.: 2.6 100 1.720 172 0.420 107 42 Ductwork: 858 686 AED Excursion: 533 Room Totals: 3,393 107 3,372 a C:\ ...\Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM Rhvac Resldeotial & Light Commercial HVAC Loads Elite Software Development, Inc. ` vResidenbil' Energy Cale: :. Majestic ,Homes : Port3ai4fLucie, FL :4993 ° . .. Page 14 Detailed Room Loads - Room 7 - Family (Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 18.0 ft. System Number: 1 Room Width: 15.0 ft. Zone Number: 1 Area: 270.0 sq.ft. Supply Air: 418 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 9.3 AC/hr Volume: 2,700.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 4 Actual Winter Vent.: 4 CFM Runout Air: 104 CFM Percent of Supply.: 1 % Runout Duct Size: 6 in. Actual Summer Vent.: 5 CFM Runout Air Velocity: 532 ft./min. Percent of Supply: 1 % Runout Air Velocity: 532 ft./min. Actual Winter Infil.: 11 CFM Actual Loss: 0.181 in.wg./100 ft. Actual Summer Infil.: 5 CFM rSen Clg L#at ° 7 Sen . Iterni i fi Y Area U ' t Htg i. now z`G2uantit �1_ DeSc i t�on`y,tt � Value >n:; W -Wall-13A-4ocs 19 X 10 97 0.143 4.0 388 2.2 0 212 W -GIs-1A-cb-o shgc-0.75 16%S 45 1.080 30.2 1,361 79.0 0 3,554 W -GIs-1A-cm-o shgc-0.75 100%S 48 1.270 35.6 1,707 34.8 0 1,672 UP-Ceil-I6C-30 18 X 15 270. 0.032 0.9 242 1.3 0 346 Floor-22A-ph 19 ft..Per. 19 1.358 38.0 722 0._0 0 0 Subtotals for Structure: 4,420 0 5,784 Infil.: Win.: 10.6, Sum.: 4.9 190 1.721 327 0.426 203 81 Ductwork: 1,606 1,868 AED Excursion: 1,452 Room Totals: 6,353 203 9,185 ift 0 C:1... 1Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Residential Energy Gilds' Majestic Homes Port Saint Lucie, FL 34983 Page 15, Detailed Room Loads - Room 8 -_ Bedroom 2 (Average Load Procedure) 9- OAl z ,.: .. �: ��:. Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.0 ft. System Number: 1 Room Width: 14.0 ft. Zone Number: 1 Area: 196.0 sq.ft. Supply Air: 231 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 8.8 AC/hr Volume: 1,568.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 2 CFM Runout Air: 77 CFM Percent of Supply.: 1 % Runout Duct Size: 5 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 564 ft./min. Percent of Supply: 1 % Runout Air Velocity: 564 ft./min. Actual Winter Infil.: 13 CFM Actual Loss: 0.262 in.wg./100 ft. Actual Summer Infil.: 6 CFM Iterri ° R r;7 - '0 Area , y �� . ,..r lJ Ht�g Sen CIg LatSe�n Descn bona .4� ,f„sQ,uantt,Value ,EHTM Loss , xr.s; H7M Gam _Gain W -Wall-13A-4ocs 14 X 8 94 0.143 4.0 376 2.2 0 206 N -Wall-13A-4ocs 14 X 8 112 0.143 4.0 448 2.2 0 245 W -GIs-IA-cb-o shgc-0.75 20%S 18 1.080 30.2 544 76.6 0 1,379 UP-Ceil-16C-30 14 X 14 196 0.032 0.9 176 1.3 0 251 Floor-22A-ph 28 ft.._Per. 28 _ 1.35_838._0 1,065 0.0 0 0 — Subtotals for Structure: 2,609 0 2,081 Infil.: Win.: 12.5, Sum.: 5.8 224 1.719 385 0.424 239 95 Ductwork: 1,013 1,031 AED Excursion: 801 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: ----------- --- --- -- ---- 0 ----- 600 Room Totals: 4,007 639 5,068 C:\ ...1Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM Rhyac - R®sidentiah &Light Commercial HVAC LoadsSoftwareDevelopment; .• EI M ,, kesid'enbal Energy Calc s '. f ;i?ort Saint; Lucie, FL 34963 . Detailed Room Loads - Room 9 - Bath 2 (Average Load Procedure) 'General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.0 ft. System Number: 1 Room Width: 7.0 ft. Zone Number: 1 Area: 98.0. sq.ft. Supply Air: 32 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 2.0 AC/hr Volume: 980.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: 32 CFM Percent of Supply.: 2 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 367 ft./min. Percent of Supply: 1 % Runout Air Velocity: 367 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.154 in.wg./l00 ft. Actual Summer Infil.: 1 CFM Item Area -U- Htg .. Se n Clg Lat ••. Zen,Description Quanti Value HTM ; ' Loss HTM Gain N -Wall-13A-4ocs 7 X 8 50 0.143 4.0 200 2.2 0 109 192 N -GIs-IA-cb-o shgc-0.75 100%S 6 1.080 30.2 181 32.0 1.3 0 0 125 UP-Ceil-16C-30 14 X 7 98 0.032 0.9 88 0 Floor-22A ph 7 ft._Per.------- -- — --- --- -7-- --- 1_358 -- -- 38.0 --- - 266 ---- 0.0 - ---- —0 ---- Subtotals for Structure: 56 735 1.714 96 0.429 0 60 42 24 Infil.: Win.: 3.1, Sum.: 1.4 281 143 Ductwork: 111 AED Excursion: Room Totals: 1,112 60 705 tj;- � .� •} t 1 1 CA ...Wlajectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM Rhvac - Resedential &' Light Commercial HVAC Loads Elite Software Development, Inc. Residential Energy Calds Majestic Homes' Port Saint Lucie, FL U983 Page 17 Detailed Room Loads - Room 10 - Bedroom 3 (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.0 ft. System Number: 1 Room Width: 13.5 ft. Zone Number: 1 Area: 189.0 sq.ft. Supply Air: 123 CFM Ceiling Height: - 8.0 ft. Supply Air Changes: 4.9 AC/hr Volume: 1,512.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 2 CFM Runout Air: 62 CFM Percent of Supply.: 2 % Runout Duct Size: 5 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 452 ft./min. Percent of Supply: 1 % Runout Air Velocity: 452 ft./min. Actual Winter Infil.: 12 CFM Actual Loss: 0.169 in.wg./l00 ft. Actual Summer Infil.: 6 CFM Item . Area U-. Htg Sen Glg Lat Sian Description �Quan4i 'Value.` HTM','� Lo s' HTf1A ;= Gam, Gain N -Wall-13A-4ocs 13.5 X 8 90 0.143 4.0 360 2.2 0 197 E -Part-15°/15°-12B-Osw 14 X 8 112 0.097 1.5 163 1.5 0 163 N -GIs-IA-cb-o shgc-0.75 100%S 18 1.080 30.2 544 32.0 0 576 UP-Cell-16C-30 14 X 13.5 189 0.032 0.9 169 1.3 0 242 Floor-22A-ph 28 ft..Per. 28 1,358 38.0 1,065 0.0 0 0 Subtotals for Structure: 2,301 0 1,178 Infil.: Win.: 12.3, Sum.: 5.7 220 1.718 378 0.423 235 93 Ductwork: 906 551 AED Excursion: 429 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 600 0 Room Totals: 3,585 1,235 2,711 7 j C:\ ...\Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM Rhvac Residential &Light Commercial HVAC Loads 'Elite' Software Development, Inc- ResitlenW Energy Cald Majestic Homes' Port Saint Ckie FL 34983 Pa a 18 Detailed ROOM Loads - Room I - Laundry (Awerage, Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 8.0 ft. System Number: 1 Room Width: 6.0 ft. Zone Number: 1 Area: 48.0 sq.ft. Supply Air: 40 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 5.0 AC/hr Volume: 480.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 40 CFM Percent, of Supply.: 1 % Runout Duct Size:' 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 459 ft./min. Percent of Supply: 1 % Runout Air Velocity: 459 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.239 in.wg./100 ft. Actual Summer Infil.: 1 CFM 3 - _ -. t 4. Aq- A ,.. Item n , <;: J zArea... UHtg ' �F ° ;Send INC ; fiLat Sen, Desch bony" :yL fi x �f ;QuaityAValue d s, HTM` ,Lo_ss��. r s �, �� jUl Gam, h Gain E -Part-I5°/15°-13A-flocs 6 X 8 27 0.143 2.1 58 2.1 0 58 E-Door-11 D 3 X 7 21 0.390 5.9 123 5.9 0 123 UP-Ceil-16C-30 8 X 6 48 0.032 0.9 43 1.3 0 61 Floor-22A,ph 6 ft.. Per. 6 1.358 38.0 228 0.0 0 0 Subtotals for Structure: 452 0 242 Infil.: Win.: 2.7, Sum.: 1.2 48 1.729 83 0.417 51 20 Ductwork: 181 179 AED Excursion: 139 Equipment: 300 300 Room Totals: 716 351 880 Y Q\ ...\Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM Light Comm Commercial HVAC Loads . , Elite Software Development, Inc.' Residential Energy do Majestic Homes i?ortSaint Lucie, FL 34983 Page 19 Detailed Room Loads - Room 12 - Kitchen (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.0 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 168.0 sq.ft. Supply Air: 113 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 4.0 AC/hr Volume: 1,680.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 1 CFM Runout Air: 57 CFM Percent of Supply.: 1 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 649 ft./min. Percent of Supply: 1 % Runout Air Velocity: 649 .ft./min. Actual Winter Infil.: 7 CFM Actual Loss: 0.473 in.wg./100 ft. Actual Summer Infil.: 3 CFM L''i5'i we. g E -Wall-13A-4ocs 12 X 10 120 0.143 4.0 480 2.2 0 263 UP-Ceil-16C-30 14 X 12 168 0.032 0.9 151 1.3 0 215 Floor-22A-ph 12 ft..Per. 12 1.358 38.0 456 0.0 0 0 Subtotals for Structure: 1,087 0 478 Infil.: Win.: 6.7, Sum.: 3.1 120 1.717 206 0.425 128 51 Ductwork: 437 506 AED Excursion: 393 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 600 600 _ Room Totals: 1,730 1,128 2,489 r 4 � y C:\ ...\Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM Rh+rac lilesidential & Light Commercial HVAC Loads Elite Software Development, lnc. ' Residential Energy Cods :. < < Majestic Homes port Saint Lucie,. FL 34983 Pa a 20 Detaiied Room Loads - Room 13 - Dining (Average Load Procedure) Geney.,.. ralVfi Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 16.0 ft. System Number: 1 Room Width: 13.0 ft. Zone Number: 1 Area: 208.0 sq.ft. Supply Air: 221 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 6.4 AC/hr Volume: 2,080.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 2 CFM Runout Air: 74 CFM Percent of Supply.: 1 % Runout Duct Size: 5 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 541 ft./min. Percent of Supply: 1 % Runout Air Velocity: 541 ft./min. Actual Winter Infil.: 7 CFM Actual Loss: 0.241 in.wg./100 ft. Actual Summer Infil.: 3 CFM Descrl tion:,,, . .. yQuanti ,. � :. F�i�l"M .. , ...LoSs ,. , h_,, I•il'M Gain... Gam.: E -Wall-13A-4ocs 13 X 10 100 0.143 4.0 400 2.2 0 219 E -GIs-1A-cb-o shgc-0.75 20%S 24 1.080 30.2 726 76.6 0 1,839 E -GIs-1A-cm-o shgc-0.75 83%S 6 1.270 35.6 213 44.5 0 267 UP-Ceil-16C-30 16 X 13 208 0.032 0.9 186 1.3 0 266 Floor-22A-ph 13 ft..Per. 13 1.358 38.0 494 0.0 _ 0 _ 0 Subtotals for Structure: 2,019 0 2,591 Infil.: Win.: 7.3, Sum.: 3.3 130 1.723 224 0.423 139 55 Ductwork: 759 989 AED Excursion: - 769 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 600 0 Room Totals: _ 3,002 _ 1,139 4,864 C:\ ...\Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM R2sadential Light Commercial HVAC Loads Elite.Software DevelopmentInc.esidential Energy C'alc s iRd Majestic Homes. rteSak Lucie, FL 34983 Pa e,21 System 1 Room Load Summary a Htg Mm Y, Run_, Rung RL s �Clg� Clg�rtMinp� u';Act No, Name 8F ... Btuh;'�, ---Zone 1--- 1 Foyer 33 1,445 19 1-5 537 1,610 364 73 73 2 Office 125 2,673 35 2-5 643 3,854 707 175 175 3 Master Bath 180 5,118 67 2-5 464 2,783 899 127 127 4 Walk In Closet 77 877 11 1-4 446 855 360 39 39 5 Master Bedroom 323 7,729 100 3-6 556 7,201 1,444 328 328 6 Living 360 3,393 44 2-5 563 3,372 107 153 153 7 Family 270 6,353 83 4-6 532 9,185 203 418 418 8 Bedroom 2 196 4,007 52 3-5 564 5,068 639 231 231 9 Bath 2 98 1,112 14 1-4 367 705 60 32 32 10 Bedroom 3 189 3,585 47 2-5 452 2,711 1,235 123 123 11 Laundry 48 716 9 1-4 459 880 351 40 40 12 Kitchen 168 1,730 22 2-4 649 2,489 1,128 113 113 13 Dining 208 3,002 39 3-5 541 4,864 1,139 221 221 Ventilation 769 412 1,038 Duct Latent 2,260 _ System 1 total _ _ 2,275 42,508 543 _- _ _ 45,990 11,934_ 2,074 _ 2,074 System 1 Main Trunk Size: 20x20 in. Velocity: 746 ft./min Loss per 100 ft.: 0.052 in.wg Conlin S" sfem Sui.nrn `- ,.:. , Y Cooling Sensible/Latent Sensible ,U Latent,E Tofal' l"FA ."Y zE Tons t'` Slit. :n Btuh� s'v , s *'Btuh�fBtuh` Net Required: 4.83 79% / 21 % 45,990 11,934 57,924 Actual: 4.88 79% / 21 % 46,500 12,000 58,500 Heating System Coolinq System Type: Two Speed Heat Pump Standard Air Conditioner Model: RXBH124A10J 14PJL60A01 Indoor Model: RHLLHM6024JA Brand: PRESTIGE SERIES PRESTIGE SERIES Description: HEAT PUMP HSPF 9.0 14 SEER WITH HEAT PUMP Efficiency: Hi: 9 / Lo: 0 HSPF 14 SEER Sound: 0 0 Capacity: 58,500 Btuh 58,500 Btuh Sensible Capacity: n/a 46,500 Btuh Latent Capacity: n/a 12,000 Btuh L a V C:\ ...\Majectic Homes.rh9 Sunday, June 01, 2014, 12:32 PM