Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSFee Due: 'ermit # Planning & Development Services Building & Code Regulations Division 2300 Virginia Ave. L) Fort Pierce, FL 34982 By (772)462-1553 fit. LUC1e County SPECIALTY PERMIT APPLICATION ❑ Electrical ❑ Plumbing 6AC ❑ Fence ❑ Shed ❑ Demolition ❑ Gas ❑ Siding Seepage 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: t�}� S�J X Kozo U 2. • Parcel ID Number: ✓ 6 I �� S ` �� �d� 3. Office Use Only Section Township Range Map Page Zoning an Use Initials of Project or Work: _ tAJQLj) �2.c�.noX S 4�k S-e --e v- "I lu YM 4. Owners Information 5. Contractors Information Name: _S�eK&Lk FL Reg/Cert #: Address: ,3%'o ski); k'ews'Cs- glu County Cert#: City: Ph{'C- �� Locle- Zip:' �3 State: Business Name: Phone: &)J�-55r7,q b WPhone_Z1-533a 91 m 6. Value of Construction: $ 0 IS -® LX C c) C o14 L200 Fax: �33"lt6a nr' �i-�I�l-3Y4a OWNER'S AFFIDAVIT: I certify that all of the information contained in this apDlication is correct and that all work will be done in compliance with all applicable laws regulating cbns an zoning. PRINT OWNER OR CONTRACTOR NAME SI NAT OF OWNER OR CONTRACTOR STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME TIES DAY OF 20 13 , BY k bp-,T per<\_s 1 ' `encA WHO IS PERSONALLY KNOWN TO ME o' OR WHO HAS PRODUCED t: , . 1'UBL �✓,,:,� i�OF4ORtBA AS IDENTIFICATION. f r` ' , SUSM J. Con)i,-r ,�-- �� a C©r� nQ� ; v' ° ' 4- S60B #.DD997020 ' L �''� ``-01 ATURE OF ARY TYPE OR PRINT NAME OF NOTARY 11t+a ati«,ir . , YOl ¢ 1r1NTIC BONDA+G CO, INC. COMMISSION NUMBER �� NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING. TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $7500.00 Revised 04/26/2010 NOTICE TO OWNER: FA3= a, E TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR MTROVEMENTs TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $5,000. INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink only) or typed. This permit application is to be used only for those activities that are not otherwise included under a primary building,permit. This application may not be used for any activity that includes structural alteration. The information to be provided with this application includes: 1. Location/Site Address 2. Parcel ED plumber 3. Description of Project or Work Activity 4. Owner Information 5. Contractor Information 6. Value of Construction Indicate the street address or general location of property where the building activity is taking place. Indicate the tax identification number of the property where the building activity is taking place. Fully describe the activity to take place. Indicate the name and address of the owner of the property on which activity is taking place. Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all current retail material and labor costs associated with the building/construction activity. Construction value is used to determine the permit fee. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. ® Gas Attach 2 piping schematics with tank size, location, and BTU of each appliance Shedd: Attach 2 plot plans, 2 copies of DCA. letter and plans, 2 anchor specifications ® Fence Attach 2 plot plans showing location of fence height of fence and type of fence Siding Attach 2 copies of manufactures specifications ® HVAC Attach 2 residential energy studies, 2 manual J calculations. 2 sets of duct layouts for new system or full replacement This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday throughTriday. NOTE. Emergency electric service change out inspections will not he performed after 3: 00 PM without special arrangements and additional fee paid. Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261. This combination qualifies for a Federal Energy' Efficiency Tax Credit when placed in service'. between Feb 17, 2009 and Dec 31, 2013.I Certif 01cate of Product Ratlnqs AHRI Certified Reference Number: 5211270 Date: 7/31/2013 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 14ACX-024-230-12 Indoor Unit Model Number: CBX27UH-024-230*+TDR Manufacturer: LENNOX INDUSTRIES, INC. Trade/Brand name: 14ACX SERIES Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC. Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 24400 EER Rating (Cooling): 13.00 SEER -Rating (Cooling) ; „= ,46,.00 a FootNote 11 The AHRI 210/240 certified EER ratings are calculated under the same methodology as the EER ratings at Ti conditions of ISO 5151:2010 and ISO 13253:2011. * Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at sm, mahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at Wow.ahridirectory.org, Air -Conditioning, beating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on OngefrigerStiC)i� Institute the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2013 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130197712780229915 PRODUCT SPECIFICATIONS AIR HANDLERS Bulletin Na. 210531 May 2012 Supersades April 2012 Nominal Capacity - 1.5 to 5 Tons Optional Electric meat - 2.5 to 25 kW :.': ...e�.�,.u,v,r<t,n,. �w..,....,.:u.r,�o,�v.�<:.��,..:,,.,.s....ti..,.,. «,: ..,?�:k<..�_ !;''�..��.�..?...�.�se;�."��r�strl;,✓.,+.,.?r ��n�„iw.�'ll..:.F,.t..uLi�G.;.::,.isl.sa..?�,��; ds- h -� x�'i`� Firs? CBX27 UH - 036 - 230 -6 - 01 Unit Type Minor Revision Number CS=Air'Handler Refrigerant Type X = r'-4 10.4 Refrigerant Metering Device 2 = Fixed Orifice 3 = TXV - Bleedpon indcar unit) 4 = TXV - Dien-bleedoort (indccr ante.i Series i = TXV - Dfcn-afeedper uni(outdccr t} a = TXV - R-4 t0A Non.-blaedpar (indccr unit) - Configuration UP, = !Jpilrnrd!Hcrizontal Nominal Cooling capacir/ ions 013=1.5tans Voltage g 024 = 2 Hors 230 = 2031230V-t phasa-50h7 030=2ns ., to ' tau = 4a"OV-3 pnasa-a0h7 036 = 3 -ons Gar oe used ;airh i%8i/;atop-chum transformer require(j) 042 = 3.5 ions 043 = 4 tors 9a0 = iota N Blower Data . . . . . . . . . . . . . . . . . . . . . . . . 3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . 21 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . 6 Electric Heat Data . . . . . . . . . . . . . . . . . . . . 10 Features . . . . . . . . . . . . . . . . . . . . . . . . 2 installation Clearances'Mith Electric Heat . . . . . . . . 5 Nlodel Plumber Identification . . . . . . . . . . . . . . . 1 Optional Accessories . . . . . . . . . . . . . . . . . . . 6 Replacement Circuit Breakers . . . . . . . . . . . . . . 9 jSpecifications . . .. . . . . . . . . . . . . . . . . . . . 6 WARRANTY All covered components - five years in residential applications, one year in non-residential applications Rafer to Lennox Limited Warranty Certificate included with each unit for additional details. A 000 nvAI c Tested with matching air conditioners and heat pump units in the Lennox Research Laboratory environmental test room in accordance with AHRI Standard 210/240 Ootional electric heaters are rated in accordance with US Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations Blower performance data according to unit tests conducted in Lennox air test chamber. Air 'handlers are UL Listed to US and Canadian safety standards and components within are bonded for grounding to meet safety standards for servicing required by CEC and NEC. ISO 9001 Registered Manufacturing Quality System APPLICATIONS 1.5 to 5 ton nominal sizes. Upiiow or horizontal applications. Downfio4v applications with optional conversion kit. Applicable to expansion valve systems in cooling applications and check and expansion valve systems in heat pump applications. Wide -range check and expansion valve is factory installedd. See bulletins in section Air Conditioners for cooling capacities. See bulletins in section Heat Pump Outdoor Units for cooling and heating capacities. Optional field installed electric heaters available in several sizes for additive headno capacit'd. REFRIGERANT SYSTEM Copper Tube/Enhanced Fin Indoor Coil Lennox designed and fabricated twin coils. Assembled in °A" configuration. Provides extra large surface and contact area, excellent heat transfer and low air resistance for maximum efficiency. Precise circuiting for uniform refrigerant distribution. Precisely spaced ripple -edged aluminum fins sated to durable seamless copper tubes. Fins are strengthened to resist banding and are equipped with collars that grip tubing for maximum contact area. Lanced fins provide maximum exposure of in surface to air stream. Long life copper tubing is easy to service. Rifled tubing provides superior heat transfer. Flared shoulder tubing joints and silver soldering provide tight, leakproof joints. Coil thoroughly factory tasted under high pressure to insure leakproof construction,. Refrigerant Line Connections Suction (vapor) and liquid lines have sweat connections that extended outside of the cabinet for ease of connection. See dimension drawings for locations. 0 Check and Expansion Valve Furnished For use with R-41OA systems. V�)p�'tr �M; e valve C � /,d rarsge va! v- with .,nadeif, style fitting. Factory installed on all rnodels, internal to cabinet. CSX27UH I Paige 2 � SCry���JiCC��a �# �-..: ay f��t,F,..i t.[ J j4 z'�.Vy�y n �r. yJL '�v��a .'a� � 4k`S +Sr#��-. .}�'��'`.., �"dl )€3�'. .��t f J`'tk�+« f1M1�Y v, k �. �r fd •�s,�.;.. �KV yP ie�1�3�,�? .:.aLt �f «.<R..;,.?r., �I x.... �! ...? {t �. �� . � 3, k. �' 1:uxdi,.:c,t&,.x7.;,Y�' �x'.x,�il`i s 3 ,, h �,af ✓ ' - s 7 � s �2' t a .v +' f 9,. _. � # S, t xt +Yi - �. l ^� ��ca. BLOWER Programmable Multi -Speed Blower Motor Programmable high efficiency multi -speed blower motor. By maintaining constant torque output, blower motor can deliver more uniform (but not constant) airflow over the static pressure range> Programmable multi -speed 4 operation is achieved by the „ use of an ECM (Electronically ; Commutated Motor) motor. Leadless blower motor features simple plug-in connections. Choice of blower speeds is available. See Blower Data tables. Blower speed change is easily accomplished by a simple wiring change. Blower Assembly Lennox designed and built, direct drive blower. Each blower is statically and dynamically balanced as an assembly before installation in the unit. Blower motor is resiliently mounted to blower assembly. Blower slides out of cabinet for servicing. CABINET Constructed of heavy -gauge galvanized steel. Completely insulated with thick fiberglass insulation. Pre -painted steel cabinets have mildly textured enamel finish with primer coat on unpainted side of all panels. Units are shipped in one piece but may be disassembled into two separate sections for ease of installation in tight applications. See dimension drawings. Thick rubber gasket between sections of the two piece cabinets provides an air tight seal. No external screw heads on sides of cabinet for tight installations without damage to walls or woodwork. Removable panels provide complete service access. Electrical inlets provided in sides and top of cabinet. See dimension drawings for locations. Low Leakage Cabinet All models have less than 2% air leakage and meet ANSI/ASHIRAE Standard 193-2010 "i4lethod of Test for Deterrraining the Air Tightness of HVAC Equipment". Upflow/Horizontal Capability (Optional Downflow) Shipped for upfiow and horizontal left-hand discharge. May be field converted to horizontal right-hand air discharge by repositioning horizontal drain pan. Optional downflow kit available for field conversion. Dual Position Drain Pans Drain pars designed for Upflow, dminrlow or horizontal applications. Deep, ccrrosion resistant clastic drain pans have dual pipe drains. See dimension draavinas. OPTiONS Downflow Combustible Flooring Floor Base Base is required for models with electric heat installed in do+wnflc+w position on combustible floors. Downflow Conversion Kit Required for field conversion to downflow position. Kit consists of drip shields and 2 brackets for repositioning coil and drain pan. See Specifications table. Horizontal Support Frame Kit Provides support of unit in horizontal applications. Consists of (2) 1 x 1-1/2 x 32-5/8 in. and (2) 1 x 3 x 53-7/8 in. painted heavy gauge cold rolled steel support channels with assembly and suspending holes. Bolts and nuts furnished for field assembly. Suspending rods must be field provided. Side Return Unit Stand (Upflow Only) Raises unit 16 in. above floor for side return air duct connection. Eliminates need for wooden platform construction. All aluminum construction. Two adjustable frames fit-018/024 thru -060 models. Wall Hanging Bracket Kit (Upflow Only) Allows unit to be hung on wall at any height. Consists of heavy -gauge steel support brackets (one for air handler, one for wall mount). Screws furnished for fastening one bracket to unit. Bolts for fastening one bracket to wall are field provided. Coy(? t UH i Page 3 ' J a - L - ''{ ®esi nStar Load Calculation RUU g �r m . `N�,•� IaE�` fie, . tl'T�,K+`. ��.��i ,.q �Sy` ��� y .75 Ceiling height 01, Floor U-value j R-value 0.2 , 5 +.... Windo,,Ai U-value 1.0 ..... .....:.., . L Moisture grains 64 Fk Duct gain °gayy }}qq ' � 4 L�t� ti.� :Jn y�10 Heating infiltration ( CH11 0.6 Sure er ventilation v Daily range m Moisture difference 64 Design temperabure differenceff) 23 15 Area Btuh % of load Floor 0 0 :3 Y Windows 3450 32.2 �29- Sa System E-idency Loss Heating Loads 10,722 BTU/Fr Windows iency Loss iling Wall 4 Cooling Loads 24,312 BTLJihr Sensible People Load Latent People Load /-Sensible Infiltration Latent Infiltration Ceiling System Wall AED Graph 10000 — 7500 Ml p 5000 J 0 Sam 9am loam 11am T 12om 1pm' 2pm 3pm� 4pm T5pm 5pm 7pm TBpm — Hourly Loads — Average System equipment selection will be made using the following derived values. Glass (E) 75 sq. -ft. Glass (N) 11 sq. ft. Summer Outdoor 903F SurnmGtC` SIFS�' N '..::.... iF: ._ `• • . ?'.....::. 'r..::... _......:[.:... ._...... .. •...:.. ......... Summer Indoor ....:.:... ......... ......... 753E Uri131ler tigi9. Gril5��'%a Minter Outdoor 470E �llrlt�►' I,I�c�o~�i' �' - � �70�E f Sensible Cooling 19,504 Btuh . z 4 L6bEnt CiJ(11ird�� ................... .•...... ..:.. .................. Required Cooling Airflow 891 CFM , _.. ................................... ........, _ Required Heating Airflow ................ --.................. ...__._............. -........ ...................... ................................................. 139 CFN1 _.... _.................. _...... .... ......... .............. ......... _.... _............... ..... ................................... ................................... _......................... All calculations are based upon approved hvac industrf standards and procedures, and comply +wish ail local, state and federal code requirements. All computed results are Estimates, Product provided by,Energy Design Systerns and Idea Tree